首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
In a previous report, we presented our results of forty-two acetabular reconstructions, performed with use of impaction bone-grafting and a cemented polyethylene cup, in thirty-seven patients who were younger than fifty years and had a minimum of fifteen years of follow-up. The present update study shows the results after twenty to twenty-eight years. Eight additional cups had to be revised--four because of aseptic loosening, three because of wear, and one during a revision of the stem. Three additional cups were considered loose on radiographs. Survivorship of the acetabular reconstructions, with an end point of revision for any reason, was 73% after twenty years and 52% after twenty-five years. With revision for aseptic loosening as the end point, survival was 85% after twenty years and 77% after twenty-five years; for signs of loosening on radiographs, survival was 71% at twenty years and 62% at twenty-five years. In conclusion, our previous results have declined but the technique of using impacted morselized bone graft and a cemented cup is useful for the purpose of restoring bone stock in young patients whose acetabular defects require primary or revision total hip arthroplasty.  相似文献   

3.
BACKGROUND: Acetabular bone deficiency can present a challenge during total hip arthroplasty, especially in young patients. The purpose of the present study was to evaluate the long-term clinical and radiographic outcomes of primary and revision acetabular reconstruction with use of an impaction bone-grafting technique and a cemented polyethylene cup in young patients who had preexisting acetabular bone deficiency. METHODS: Forty-two consecutive acetabular reconstructions were performed in thirty-seven patients who were younger than fifty years old (average, 37.2 years old). The impaction bone-grafting technique was used for twenty-three primary and nineteen revision acetabular reconstructions. Twenty-eight patients (thirty-one hips) were available for review after a minimum duration of follow-up of fifteen years. Clinical and radiographic results were assessed, and survivorship analysis was performed with the Kaplan-Meier method. RESULTS: Eight hips were revised at a mean of twelve years (range, three to twenty-one years) after a primary reconstruction (four hips) or revision reconstruction (four hips). The revision was performed because of aseptic loosening of the acetabular component in four hips and because of culture-proven septic loosening in two. Two additional cups (both in hips that had had a revision reconstruction) were revised, during revision of the femoral stem, because of wear (one hip) or because of persistent intraoperative instability (one hip). Twenty-eight hips (in twenty-five patients) had retention of the acetabular component for a minimum of fifteen years. The mean Harris hip score for that group was 89 points. Twenty-six of these twenty-eight hips had no or slight pain. Kaplan-Meier analysis revealed a twenty-year survival rate of 80% (95% confidence interval, 67% to 94%) with acetabular revision for any reason as the end point and of 91% (95% confidence interval, 80% to 100%) with acetabular revision because of aseptic loosening as the end point. CONCLUSIONS: Acetabular reconstruction with use of impaction bone-grafting and a cemented polyethylene cup is a reliable and durable technique that is associated with good long-term results in young patients with acetabular bone-stock defects.  相似文献   

4.
BackgroundThe increasing number of THAs in younger patients will inevitably result in an increase of revision procedures. However, there is little evidence about the outcome of revision procedures in this patient group. Therefore, we updated a previous study conducted 5 years ago about the outcome of revision procedures in patients younger than 55 years.Questions/purposesWe sought to provide a concise update on the previously reported (1) long-term failure rate as defined by repeat revision, (2) clinical outcome as defined by the Oxford Hip score and the Harris Hip score, and (3) radiographic outcome of cemented revision THA performed with impaction bone grafting on both the acetabular and femoral sides in one surgery in patients younger than 55 years old.MethodsBetween 1991 and 2007, we performed 86 complete THA revisions in patients younger than 55 years. In 38% (33 of 86) of revisions, bone impaction grafting was used on both the acetabular and femoral side because of acetabular and femoral bone stock loss. Mean age at time of revision was 46 ± 8 years. No patient was lost to follow-up, but six patients died during follow-up, including three since 2015. Still, the hips of all 33 patients were included in analysis at a mean of 17 ± 5 years. Failure was calculated using competing risk analysis. For clinical outcome, we assessed the Harris Hip score and the Oxford Hip score from our longitudinally maintained institutional database. Radiographic analysis was performed to evaluate radiographic loosening, defined as radiolucencies ≥ 2 mm in all zones or ≥ 5 mm migration for both components. The acetabular component was also considered loose with tilting ≥ 5°ResultsThe 15-year failure rate of revision THA was 27% (95% CI 13 to 44) for re-revision of any component for any reason and 10% (95% CI 3 to 25) for re-revision of any component for aseptic loosening. The mean Harris Hip score increased from 55 ± 18 preoperatively to 74 ± 22 at latest follow-up. Eight cups were considered radiographically loose, seven of which were re-revised. No stems were considered radiographically loose. Failure rate with endpoint radiographic loosening at 15 years was 23% (95% CI 10 to 39).ConclusionWe found that impaction bone grafting with a cemented cup and a cemented stem is a valuable biological revision technique that results in a stable and durable solution, after one or even multiple previous revision THAs. Although current implants may prove sufficient in most cases, they do not promote bone stock preservation. We believe that in young patients with bone stock loss, impaction bone grafting can be used as long as the defect can be contained adequately with a metal mesh and viable bone bed is available for revascularization.Level of EvidenceLevel IV, therapeutic study.  相似文献   

5.
6.
BackgroundInstability and aseptic loosening are the two main complications after revision total hip arthroplasty (rTHA). Dual-mobility (DM) cups were shown to counteract implant instability during rTHA. To our knowledge, no study evaluated the 10-year outcomes of rTHA using DM cups, cemented into a metal reinforcement ring, in cases of severe acetabular bone loss. We hypothesized that using a DM cup cemented into a metal ring is a reliable technique for rTHA at 10 years, with few revisions for acetabular loosening and/or instability.MethodsThis is a retrospective study of 77 rTHA cases with severe acetabular bone loss (Paprosky ≥ 2C) treated exclusively with a DM cup (NOVAE STICK; Serf, Décines-Charpieu, France) cemented into a cage (Kerboull cross, Burch-Schneider, or ARM rings). Clinical scores and radiological assessments were performed preoperatively and at the last follow-up. The main endpoints were revision surgery for aseptic loosening or recurring dislocation.ResultsWith a mean follow-up of 10.7 years [2.1-16.2], 3 patients were reoperated because of aseptic acetabular loosening (3.9%) at 9.6 years [7-12]. Seven patients (9.45%) dislocated their hip implant, only 1 suffered from chronic instability (1.3%). Cup survivorship was 96.1% at 10 years. No sign of progressive radiolucent lines were found and bone graft integration was satisfactory for 91% of the patients.ConclusionThe use of a DM cup cemented into a metal ring during rTHA with complex acetabular bone loss was associated with low revision rates for either acetabular loosening or chronic instability at 10 years.  相似文献   

7.
《The Journal of arthroplasty》2022,37(5):897-904.e1
BackgroundTotal hip arthroplasty (THA) for avascular necrosis (AVN) or inflammatory arthritis (IA) comes with a relatively high risk of aseptic stem loosening, especially in young patients. There are limited long-term data on the survivorship of polished, tapered, cemented stems in this population. We therefore performed a single-center retrospective study investigating the survival of this particular stem type in young patients with AVN or IA.MethodsAll patients aged ≤35 years who had received a THA for AVN or IA operated on by the senior author between 1990 and 2010 at the University Hospitals Leuven were identified. In total, 85 THAs in 62 patients were included. Primary endpoint was revision of the femoral component for aseptic loosening. Secondary endpoints were revision of the acetabular component for aseptic loosening, revision for other reasons, and the presence of radiolucencies around the components.ResultsThe mean follow-up for the entire cohort was 18.0 ± 5.3 years (range 8.0-28.9). Taking revision for aseptic loosening as endpoint, the survival of cemented stems was 100% after 15 years and 95.1% after 20 years. Survival of uncemented cups (91.3%) was significantly better than survival of cemented cups (50.3%) after 20 years of follow-up for aseptic loosening. Taking revision for any reason as endpoint, the survival of THAs with uncemented and cemented cups was 90% and 43.1% at 20 years respectively. Radiolucencies developed in the cement mantles around 11 of the 81 nonrevised stems, mainly in zones 1 and 7.ConclusionIn this cohort of young patients with high-risk profiles for aseptic stem loosening, polished, tapered, cemented stems showed excellent long-term survival rates and they therefore remain a viable alternative to uncemented stem designs.  相似文献   

8.
The survival of acetabular components depends on several factors: wear, osteolysis and septic or aseptic loosening. Osteolysis seems to be the main cause for concern in cementless arthroplasties. Acetabular osteolysis results from particle debris and segmental unloading of acetabular bone by rigid sockets. We investigated a cementless elastic monoblock socket with regard to acetabular osteolysis and aseptic loosening in a cohort of young patients. We evaluated 158 hip arthroplasties with a minimum follow-up of ten years (ten to 18) and a mean age of 42 years (18–50). The overall revision rate at 14 years was 80% with a 98% survival rate for aseptic loosening. The mean polyethylene wear rate was 0.11 mm/year. Progressive acetabular osteolysis was seen in 3% of patients evaluated. In conclusion, we found low pelvic osteolysis rates, acceptable overall wear rates, satisfactory overall survival and excellent survival rates for aseptic loosening of a cementless elastic monoblock socket in patients younger than 50 years. Ongoing tribology developments and knowledge about acetabular bone adaptations behind acetabular implants will further lower wear and osteolysis rates and optimise survival rates of cementless sockets.  相似文献   

9.

Purpose

Patients suffering from post traumatic osteoarthritis of the acetabulum often require a total hip arthroplasty at a relatively young age. Long-term data outcome studies for this population are lacking. We report on the long-term outcome of 20 acetabular fractures in 20 patients treated with impaction bone grafting and a cemented cup after a mean follow-up of 18 years (range, 12–26 years).

Methods

The group consisted of 14 males (70 %) and six females (30 %) with an average age of 53.3 years (range, 35–75 years) at time of surgery. No patients were lost to follow-up. Four patients died and three patients underwent a revision; at review 13 patients were still living with their implant in situ. Survivorship analysis was performed at 20 years follow-up for three endpoints.

Results

Survival rate with endpoint revision for any reason at 20 years postoperative was 74.7 % (95 % confidence interval (CI), 40–91 %), 80.0 % (95 % CI, 41–95 %) for endpoint aseptic loosening, and 63.9 % (95 % CI 32–84 %) for endpoint radiographic failure. Three acetabular components were revised at 14.5, 15.3, and 16.7 years postoperative. Two cups failed for aseptic loosening and one cup failed due to septic loosening. The average postoperative Harris hip score was 82 (range, 56–100).

Conclusion

Acetabular reconstruction with impaction bone grafting and the use of a cemented cup after acetabular fracture is an attractive technique with acceptable long-term results and a low complication and re-operation rate.  相似文献   

10.
We report the results of the revision of 123 acetabular components for aseptic loosening treated by impaction bone grafting using frozen, morsellised, irradiated femoral heads and cemented sockets. This is the first large series using this technique to be reported. A survivorship of 88% with revision as the end-point after a mean of five years is comparable with that of other series.  相似文献   

11.

Background

The increasing number of total hip arthroplasties (THAs) performed in younger patients will inevitably generate larger numbers of revision procedures for this specific group of patients. Unfortunately, no satisfying revision method with acceptable survivorship 10 years after revision has been described for these patients so far.

Questions/purposes

The purposes of this study were to (1) analyze the clinical outcome; (2) complication rate; (3) survivorship; and (4) radiographic outcome of cemented revision THA performed with impaction bone grafting (IBG) on both the acetabular and femoral sides in one surgery in patients younger than 55 years old.

Methods

During the period 1991 to 2007, 86 complete THA revisions were performed at our institution in patients younger than 55 years. In 34 of these 86 revisions (40%), IBG was used on both the acetabular and femoral sides in 33 patients. Mean patient age at revision surgery was 46.4 years (SD 7.6). No patient was lost to followup, but three patients died during followup. None of the deaths were related to the revision surgery. The mean followup for the surviving hips was 11.7 years (SD 4.6). We also analyzed complication rate.

Results

The mean Harris hip score improved from 55 (SD 18) preoperatively to 80 points (SD 16) at latest followup (p = 0.009). Six hips underwent a rerevision (18%): in four patients, both components were rerevised; and in two hips, only the cup was revised. Patient 10-year survival rate with the endpoint of rerevision for any component for any reason was 87% (95% confidence interval [CI], 67%–95%) and with the endpoint of rerevision for aseptic loosening, the survival rate was 97% (95% CI, 80%–100%). In total six cups were considered radiographically loose, of which four were rerevised. Three stems were radiographically loose, of which none was rerevised.

Conclusions

IBG is a valuable biological revision technique that may restore bone stock in younger patients. Bone stock reconstruction is important, because these patients likely will outlive their revision implants. Bone reconstruction with impaction grafting may facilitate future revisions.

Level of Evidence

Level IV, therapeutic study.  相似文献   

12.
In the 1970s, high failure rates of cemented acetabular components, especially in young patients, in the middle- and long-term prompted a search for alternatives. The Mecring was one of the most popular first generation uncemented, threaded cups widely used in the 1980s for arthroplasty of the hip. First generation threaded cups commonly had smooth surface treatment and showed unacceptably high failure rates in the mid-term. In a consecutive series of 209 patients, 221 threaded uncemented acetabular cups with smooth surface treatment (Mecring) had been implanted in combination with one type of uncemented stem. Patients were followed up clinically and radiographically. The mean time of follow-up was 17 (range 15–20) years. In 91 (41%) hips the acetabular component had been revised or was awaiting revision: two hips for infection and 84 (38%) for aseptic loosening. Five hips were awaiting revision. The survival rate for all revisions including hips awaiting revision was 49% (95% CI: 41–57%) at 17 years. These results support the view that smooth, threaded acetabular components do not provide satisfactory long-term fixation and should be abandoned. Patients with these components must be closely monitored as the failure rate remains high in the long-term.  相似文献   

13.
背景:颗粒骨打压植骨是修复髋臼骨缺损的重要方法,对大面积髋臼骨缺损采用打压植骨结合非骨水泥臼杯重建仍然存在争议。目的:探讨同种异体颗粒骨打压植骨结合多孔非骨水泥臼杯髋臼重建术修复AAOSⅢ型髋臼大面积骨缺损的方法及近期疗效。方法:随访2005年6月至2010年4月收治的28例(28髋)AA0SⅢ型髋臼大面积骨缺损患者。男18例,女10例,年龄34-74岁,平均53.8岁。髋关节置换术后感染醐翻修9例,骨溶解及髋臼假体松动翻修19例。本组AAOSⅢ型髋臼骨缺损面积大,术中见髋臼骨缺损超过髋臼关节面的50%。全部采用同种异体颗粒骨打压植骨结合多孔非骨水泥臼杯髋臼重建术。术后定期随访,观察臼杯有无松动、植入骨与宿主骨整合情况,髋关节功能评分采用Harris评分。结果:28例均获得随访,术后随访时间为13-70个月,平均43个月。Harris评分由术前32-48分,平均41分,提高至末次随访时86-95分,平均90分。28例髋臼假体均固定牢固无松动征象,植入骨逐渐与宿主骨整合,无感染及坐骨神经损伤。结论:在获得臼杯初始稳定固定的情况下,大面积颗粒骨打压植骨(臼杯与宿主骨接触面积〈50%)结合多孔非骨水泥臼杯髋臼重建术修复AAOSⅢ型髋臼大面积骨缺损近期疗效较好,远期疗效尚待进一步随访。  相似文献   

14.
Host bone contact of less than 50% is perceived but not proven to cause migration and loosening after actetabular revision. A prospective analysis of cementless acetabular revision cases with impaction grafting was performed to determine if this was an independent risk factor for these events. Sixty-two hips in 54 patients were assessed at a mean follow-up of 84.5 months (range 61–112) yielding a probability of 94.6% of retaining the acetabular component using revision for aseptic loosening as the end point. No single factor was independently causative for loosening, although Type III fixation was associated with migration (p = 0.0159); subanalysis suggested that achieving host–bone contact in at least part of the dome and posterior column is important.  相似文献   

15.
We reviewed retrospectively the results of 28 hips (25 patients) after revision of the femoral component with use of a cemented stem, because of aseptic loosening. The mean duration of follow-up was 4.43 years (range 2–12 years). Over the course of the study period, repeat revision was done in 4 hips after an average of 4.45 years. Three hips had a repeat revision of the femoral component because of aseptic loosening and one for a deep infection. The rate of loosening of the femoral component was 32.4% (9 hips) at an average of 5.22 years. The 5-year survival rate was 76.9% with mechanical failure as end point; and 90% with re-revision of femoral component because of aseptic loosening as end point. The cement mantle was the principal factor, which was significantly associated with a better survival rate of femur fixation (P < 0.05). No correlation was noted between quality of bone loss at the time of revision, bone graft or the use of long stems, and the survival rate of femoral component. By improving the cementing technique and in selected patients, the use of cemented femoral stem could be a good alternative for aseptic loosening THA.  相似文献   

16.
This study is a 5- to 11-year retrospective followup of 40 hips in 33 patients with cementless acetabular revision for aseptic failure of a cemented total hip arthroplasty. A porous coated, Harris-Galante acetabular component was used in all revisions. Thirty-eight of the 40 hips received acetabular bone grafting at revision. The mean Harris Hip Score improved from 51 points just before the index cementless revision to 87 points at the most recent followup. Twenty-nine of 40 (73%) hips were classified as having a good or excellent result. Radiolucencies were observed in seven of the 40 (18%) hips at the most recent followup, but none of these radiolucencies were complete or progressive. Five of the 40 (13%) hips were rated as failures and required repeat revision. Two (5%) of these failures were caused by aseptic loosening, with both hips having severe acetabular bone damage at the time of the index revision. This failure rate for aseptic loosening was less than that reported for cemented acetabular revision, thereby confirming the efficacy of cementless acetabular components in revision hip surgery in the intermediate term.  相似文献   

17.
BACKGROUND: Acetabular revision in patients with rheumatoid arthritis is often difficult because of the poor quality and quantity of the acetabular bone stock. The purpose of this study was to evaluate the midterm clinical and radiographic outcomes of acetabular revision with use of an impaction bone-grafting technique and a cemented polyethylene cup. METHODS: Thirty-five consecutive acetabular revisions were performed with impaction bone-grafting and use of a cemented cup in twenty-eight patients with rheumatoid arthritis. The average age at the revision was fifty-seven years. The minimum duration of follow-up of all reconstructions that were still functioning or that were followed until the time of death was three years (mean, 7.5 years; range, three to fourteen years). No patient was lost to follow-up, but five patients (six hips) died before the time of the review. The acetabular bone defects were classified as cavitary in twelve hips and as combined segmental-cavitary in twenty-three. RESULTS: The five patients (six hips) who died had been doing well at the time of their latest follow-up. Of the remaining patients, six (six hips) had a repeat revision. The average Harris hip score of the living patients with a surviving implant at the time of follow-up was 82 points, and there was no or only mild pain in twenty-one of the twenty-three hips. Radiographic analysis of all twenty-nine hips that had not been revised showed loosening in one hip and a nonprogressive radiolucent line in one zone in two others. Kaplan-Meier analysis demonstrated a prosthetic survival rate, with aseptic loosening as the end point, of 90% at eight years. CONCLUSION: Acetabular revision with impaction bone-grafting and a cemented cup in patients with rheumatoid arthritis had acceptable results at an average of 7.5 years postoperatively.  相似文献   

18.

Background

The preoperative bone defect and the reconstruction of the center of rotation of the hip are critical in acetabular revision surgery. Uncemented oblong cups are employed in order to manage these issues. We analyzed the clinical results and rates of revision of two different uncemented oblong cups, the reconstruction of the center of rotation of the hip, as well as the rate of radiological loosening and possible risk factors.

Materials and methods

Forty-five patients (46 hips) underwent acetabular revision surgery using two different uncemented oblong cups. We assessed the clinical results and the survival rate for revision and aseptic loosening. Intraoperative bone loss was classified according to Paprosky, and acetabular reconstruction was assessed according to Ranawat. The mean follow-up was 7.2 years (range 4–11 years).

Results

There were four re-revisions (three due to aseptic loosening); the survival rate for re-revision due to aseptic loosening was 60.1 % at seven years. The mean distance between the center of the femoral head prosthesis and the approximate center of the femoral head improved from 21.5 to 10.2 mm. Thirteen cups showed radiological loosening; the survival rate for radiological loosening at seven years was 40.54 %. A smaller postoperative horizontal distance was correlated with cup loosening.

Conclusions

Although optimal acetabular reconstruction can be achieved by using oblong uncemented cups in revision hip surgery, the clinical and radiological results are not encouraging. Excessive medialization of the cup may increase the rate of loosening.  相似文献   

19.
A consecutive, non-selective cohort of 83 (77 patients) cemented total hip arthroplasty revisions using contemporary cementing techniques was analyzed at a minimum of 20 years following the index procedure. No patients were lost to follow-up. The average age at revision was 62.4 years (23 to 89). Twenty-two hips (26.5%) had had a reoperation, eighteen (21.7%) for aseptic loosening, 3 (3.6%) for femoral prosthesis fracture and 1 (1.2%) for dislocation. The incidence of re-revision for aseptic femoral loosening was 7.5% and for aseptic acetabular loosening was 21.7%. These results confirm that cemented femoral revision using improved cementing techniques is a durable option in revision hip surgery. In contrast to this, THA revisions using a cemented acetabular component have been less durable at this length of follow-up.  相似文献   

20.
We evaluated 66 acetabular revision arthroplasties using cemented cup with impaction bone grafting (IBG) to detect the extent that bone defect affects the outcome. We defined the maximum acetabular defect distance (MADD), which indicates the greatest depth of the grafted layer. Cup survival analysis with aseptic loosening as the endpoint revealed that the “MADD ≤ 20 mm” group showed higher survivorship than the “MADD > 20 mm” group (95% vs. 74%, P = 0.034), and that the simple-wall-defect group (none or one mesh used) showed higher survivorship than the complex-wall-defect group (two meshes used) (96% vs. 73%, P = 0.044). A favorable indication for acetabular IBG reconstruction is cases in which those cups can be placed at ≤ 20 mm MADD with a simple wall defect.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号