首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PURPOSE: To evaluate the influence of thermal and mechanical load cycling on the microtensile dentin bond strength of two self-etching and one total-etch adhesives. METHODS: The adhesive materials were: a two-step self-etch adhesive (Clearfil SE Bond), a one-step self-etch adhesive (Hybrid Bond), and a total-etch one-step adhesive (Admira Bond). Sixty freshly extracted human third molars were used. In each tooth, a Class I cavity (4 x 4 mm) was prepared in the occlusal surface with the pulpal floor extending about 1 mm into dentin. The teeth were divided into three groups (n=20). Each group was restored with the resin composite Clearfil APX using one of the adhesives. After restoration, 10 teeth in each group were thermocycled between 5 degrees C and 55 degrees C, (dwell time 3 minutes, 5,000 cycles). The same teeth were then mounted in a fatigue loading machine to receive an intermittent load of 125 N at 52 cycles/minute for 4,000 cycles. Subsequently, each tooth was sectioned longitudinally, bucco-lingually and mesio-distally to get rectangular slabs 1-1.2 mm in thickness for the microtensile test. Each slab was then placed in a universal testing machine and tensile load was applied at a cross-head speed of 0.05 mm/minute. RESULTS: Without loading procedures, there was no significant difference in the bond strength of the tested adhesives. In contrast to Admira Bond and Clearfil SE Bond, fatigue loading resulted in a significant reduction of the bond strength for Hybrid Bond when compared to the unloaded restorations.  相似文献   

2.
OBJECTIVES: To evaluate effect of direct and indirect water storage on the microtensile dentin bond strength of one total-etch and two self-etching adhesives. METHODS: The adhesive materials were: one total-etch adhesive; 'Admira Bond' and two self-etch adhesives; 'Clearfil SE Bond' and 'Hybrid Bond'. Freshly extracted human third molar teeth were used. In each tooth, a Class I cavity (4mmx4mm) was prepared in the occlusal surface with the pulpal floor extending approximately 1mm into dentin. The teeth were divided into three groups (n=18). Each group was restored with the resin composite 'Clearfil APX' using one of the tested adhesives. For each experimental group 3 test procedures (n=6) were carried out: Procedure A: the teeth were stored in water for 24h (control), then sectioned longitudinally, buccolingually and mesiodistally to get rectangular slabs of 1.0-1.2mm thickness on which a microtensile test was carried out. Procedure B: the teeth were also sectioned; however, the slabs were stored in water at 37 degrees C for 4 years before microtensile testing (direct water storage). Procedure C: the teeth were kept in water at 37 degrees C 4 years before sectioning and microtensile testing (Indirect water storage). During microtensile testing the slabs were placed in a universal testing machine and load was applied at cross-head speed of 0.5mm/min. RESULTS: For the 24h control, there was no significant difference in bond strength between the three tested adhesives. After 4 years of indirect water storage, the bond strength decreased but the reduction was not significantly different from those of 24h. After 4 years of direct water storage, the bond strengths of all tested adhesives were significantly reduced compared to their 24h results. CONCLUSION: All the tested adhesives showed no reduction in bond strength after indirect water exposure for 4 years. After 4-year direct water exposure, the bond produced by all tested adhesives was unable to resist deterioration.  相似文献   

3.
PURPOSE: To evaluate the effect of pulpal pressure on the microtensile bond strength of four self-etch adhesives to dentin. A total-etch adhesive was added for comparison. METHODS: 60 freshly extracted human third molars were selected. For each tooth, the root was removed below the cemento-enamel junction. A second parallel section was made to remove the coronal enamel to form a crown segment. The root portion of the resulting crown segment was cemented to a Plexiglas platform using cyanoacrylate cement. The crown segment was then connected with a plastic tube to a water column to produce a pressure of 20 cm H2O at the prepared dentin surface of the crown segment. The adhesive materials were: a total-etch adhesive (Scotchbond 1) and four self-etch adhesives (Clearfil SE Bond, Hybrid Bond, Futurabond NR, and AdheSE Bond). The tested adhesives were applied to the dentin surface in three test procedures: applied to dentin without pulpal pressure, applied to dentin with pulpal pressure for 24 hours, and applied to dentin with pulpal pressure and the pressure was maintained for 6 months during storage. Grandio resin composite was placed in 3-4 layers to a height of 5-6 mm to form a crown segment. For bond strength measurement, the composite-dentin segment was removed from the Plexiglas. This segment was then sectioned to prepare the specimens for microtensile bond measurement. RESULTS: None of the tested adhesives showed bond strength reduction when applied to dentin supplied with water pressure. After 6 months of pulpal pressure, Scotchbond 1, Clearfil SE Bond and AdheSE Bond showed significant reduction in bond strength (P < 0.05). In contrast, Futurabond NR and Hybrid Bond were not significantly affected.  相似文献   

4.
PURPOSE: To evaluate the long-term effects of etching time, adhesive system and storage condition on resin bond strength to dentin. METHODS: Twenty-five extracted human third molars had a flat dentin surface exposed. Two total-etch adhesives, Single Bond (SB) and One-Step (OS), and one self-etching adhesive system, Clearfil Liner Bond 2V (CL), were used. The adhesives were bonded to dentin according to their respective manufacturer's instructions. Additional groups of SB and OS systems were created, in which the phosphoric acid etching time was doubled (30 seconds). After bonding, build-up crowns were constructed incrementally with Z250 resin composite and the teeth were stored for 24 hours in distilled water at 37 degrees C. The teeth were serially and vertically sectioned to obtain several bonded beams with approximately 0.8 mm2 of cross-sectional area. Beams were tested in microtensile (0.6 mm/minute) either immediately (control) or after storage for 6 months or 1 year in either distilled water or mineral oil. Data were analyzed by ANOVA and Tukey's multiple comparison tests. RESULTS: Significant reductions (P< 0.05) in bond strength were observed after both long-term storage periods in water for all the materials, regardless of the etching time for SB and OS. Bond strengths were either preserved or increased in specimens stored in oil.  相似文献   

5.
OBJECTIVE: To investigate the effect of different dentin treatments on the microtensile bond strength of a self-etching primer and a simplified, total-etch adhesive system. METHODS: Flat dentin surfaces were created on extracted human third molars. The surfaces were treated with one of the following conditioners: self-etching primer for 20 s (Clearfil SE Primer), 37% phosphoric acid for 15 s or 0.5 M EDTA for 30 s. Conditioned surfaces were then bonded with either Clearfil SE Bond or Single Bond followed by resin composite (Z250) build-ups constructed incrementally. Application of SE Primer was included when Clearfil SE Bond was used, after phosphoric acid and EDTA conditioning. After 24 h storage in water at 37 degrees C, the teeth were longitudinally sectioned across the bonded interface to produce beams with 1.0 mm2 of adhesive area, tested with the microtensile method at a rate of 0.5 mm/min. Data were analyzed using two-way ANOVA and Tukey's test. RESULTS: The highest bond strength mean was found for the combination SE Primer/Single Bond (58.5+/-20.8 MPa), followed by the EDTA/Clearfil SE Bond (47.8+/-15.1 MPa) and phosphoric acid/Single Bond (40.9+/-14.3 MPa). The remaining combinations showed statistically similar (p>0.05) tensile bond strength. SIGNIFICANCE: The bond performance of the adhesives tested was dependent on the dentin conditioner. Pre-treatment with a mild etchant such as 0.5 M EDTA improved the bond strength of Clearfil SE Bond. Single Bond performed better when a self-etching primer was used as the dentin conditioner, probably by preventing the formation of a defective zone at the base of the hybrid layer. Overall results indicate that higher bond strengths can be achieved by conditioning dentin with milder etchants, suggesting that deeper demineralization may prevent proper resin infiltration, hence compromising the bond.  相似文献   

6.
This study aimed to evaluate the microtensile bond strength (microTBS) of photo- and dual-cure adhesives to sound and caries-affected dentin using total- and self-etch techniques. Human third molars with occlusal caries were prepared as previously described by Nakajima and others (1995). Dentin surfaces were bonded with Optibond Solo Plus (Kerr; photo-cure adhesive) or Optibond Solo Plus + Dual-cure activator (Kerr; dual-cure adhesive) with total- and self-etch technique. Clearfil AP-X (Kuraray) was used for composite buildups. Following storage in distilled water at 37 degrees C for 24 hours, the teeth were sectioned into 0.7-mm thick slices to obtain sound and caries-affected dentin slabs, then trimmed to form hour glass shapes with a 1 mm2 cross-sectional area. The specimens were subjected to microtensile testing using EZ-test (Shimadzu) at 1 mm/minute. Data were analyzed using three-way ANOVA and Student's t-Test (p<0.05). Bond strengths to sound dentin with photo- and dual-cure adhesives using total- and self-etch techniques were significantly higher than those to caries-affected dentin. Dual-cure adhesive significantly decreased bond strengths both to sound and caries-affected dentin. The total-etch technique showed no beneficial effect on caries-affected dentin compared with the self-etch technique. Scanning electron microscopic observation of the resin-dentin interfaces revealed that hybrid layers in caries-affected dentin were thicker than those observed in sound dentin with photo- and dual-cure adhesives. Resin infiltration into dentinal tubules of caries-affected dentin was hampered by the presence of mineral deposits.  相似文献   

7.
目的比较脱矿牙本质与4种全酸蚀或自酸蚀粘接剂的粘接强度及粘接界面超微结构的差异,以期对临床治疗有所指导。方法选择20颗面龋坏的离体磨牙,在龋显示剂的指示下去除牙本质龋的感染层,保留脱矿牙本质。平齐龋洞洞底平面,去除冠向牙体组织,作为粘接面。选择临床常用的2种全酸蚀粘接剂:材料A(All Bond2)、材料B(Prime&BondNT)和2种自酸蚀粘接剂:材料C(ClearfilSEBond)、材料D(XenoⅢ),分别按说明书要求粘接。用慢速锯将样本牙切为粘接面积约0.9mm×0.9mm的长方体试件。体视显微镜下将试件分为正常牙本质组和脱矿牙本质组,用微拉伸测试仪检测粘接强度。扫描电镜观察各组试件粘接界面的超微形态。结果方差分析提示牙本质类型和粘接剂对微拉伸粘接强度的影响均有统计学意义(P<0.05)。对正常牙本质,不同粘接剂的微拉伸粘接强度差异无统计学意义(P>0.05);对于脱矿牙本质,材料D的微拉伸粘接强度较其他粘接剂明显降低(P<0.05)。扫描电镜下观察脱矿牙本质的混合层多孔稀疏,树脂突短少,无侧枝形成。结论对脱矿牙本质,本项实验中全酸蚀粘接剂的粘接强度优于自酸蚀粘接剂。  相似文献   

8.
OBJECTIVE: To evaluate the effect of mechanical loading on the microtensile bond strength (MTBS) of five adhesive systems to dentin. METHODS: Flat dentin surfaces from human molars were divided into five groups and bonded with total-etch self-priming adhesives (Single Bond, Prime&Bond NT and Prime&Bond XP), two-step self-etching primer (Clearfil SE Bond) and an all-in-one adhesive (Etch&Prime 3.0), according to the manufacturers' instructions. Composite build-ups were constructed incrementally with Tetric Ceram. After 24 hours of water storage, half the specimens were load cycled (5000 cycles, 90 N). The teeth were then sectioned into beams of 1.0 mm2 cross-sectional area. Each beam was tested in tension in an Instron machine at 0.5 mm/minute. Data were analyzed by two-way ANOVA and Student Newman Keuls multiple comparisons tests (p<0.05). Results: Clearfil SE Bond and Single Bond attained higher MTBS than the other three adhesives. Prime&Bond NT and Prime&Bond XP performed equally, and Etch&Prime 3.0 resulted in the lowest MTBS. After mechanical loading, MTBS decreased in all groups except Prime&Bond XP. Clearfil SE Bond, Single Bond and Prime&Bond XP obtained higher MTBS than Prime&Bond NT. Specimens bonded with Etch&Prime 3.0 resulted in premature failures and MTBS could not be measured. Clinical RELEVANCE: When using Etch&Prime 3.0, bond structures did not withstand mechanical loading, which may have an influence on the long-term success of restorations. If dentin is acid-etched, alcohol-based adhesive systems showed higher bond strength after mechanical loading.  相似文献   

9.
OBJECTIVES: To evaluate the microtensile bond strength of total-etch or self-etch adhesives to caries-affected versus normal dentine, and to correlate these bond strengths with DIAGNOdent laser fluorescence and Knoop microhardness (KH) measurements of the substrates. METHODS: Extracted carious human molars were ground to expose flat surfaces where the caries lesion was surrounded by normal dentine. Surfaces were bonded with either Prime & Bond NT, Scotchbond 1, Clearfil SE Bond or Prompt L-Pop, according to manufacturers' recommendations. A crown was built up using resin composite (Tetric Ceram). After storage in water (37 degrees C, 24 h), teeth were vertically serially sectioned into 0.7 mm thick slabs and trimmed to yield 1 mm(2) test area that contained either caries-affected or normal dentine. Samples were tested in tension in an Instron machine at 1 mm/min. The quality of the dentine just beneath each fractured specimen was measured by laser fluorescence and KH. RESULTS: Total-etch adhesives yielded higher bond strengths than self-etching systems. Significantly lower results were obtained with Prompt L-Pop. All the adhesives attained higher strengths in normal than in caries-affected dentine, but the differences were only significant for Prime & Bond NT and Clearfil SE Bond. Higher laser fluorescence values and lower KH (p<0.001) were recorded in caries-affected dentine compared to normal dentine. CONCLUSIONS: The total-etch adhesives evaluated produced higher bond strengths to normal and caries-affected dentine than self-etching systems. Laser fluorescence measurements discriminated caries-affected dentine from normal dentine, and were strongly correlated with KH. However, laser fluorescence and KH did not permit high correlations with resin-dentine bond strengths in caries-affected dentine.  相似文献   

10.
目的比较不同类型自酸蚀牙本质粘结系统的粘结强度,为临床应用提供参考。方法选择4种自酸蚀粘结系统Clearfil S3Bond,i Bond,Clearfil SE Bond,XenoⅢ,1种全酸蚀粘结系统Single Bond2,用微拉伸法测试这些粘结系统的粘结强度并进行比较。结果全酸蚀粘结剂Single Bond2的微拉伸强度最高,与自酸蚀粘结剂粘结强度有显著差异(P〈0.05)。自酸蚀粘结剂i Bond,S3Bond,XenoⅢ两两之间粘结强度无显著差异(P〉0.05)。SE Bond的粘结强度显著高于i Bond,S3Bond和XenoⅢ(P〈0.05)。结论第五代牙本质粘结剂具有较强的粘结强度,但第七代牙本质粘结剂临床操作更为方便。  相似文献   

11.
OBJECTIVE: The purpose of this study was to evaluate the effect of a filled adhesive (One-Step Plus; Bisco) versus an unfilled adhesive (One-Step; Bisco) on the microtensile bond strength (muTBS) to dentin using total-etch (Uni-etch; Bisco) and self-etch (Tyrian SPE; Bisco) techniques. METHODS: Twenty extracted human third molars were ground flat to expose occlusal dentin. After the dentin surfaces were polished with 600-grit SiC paper, the teeth were randomly assigned to four groups according to the bonding agent and technique being used. Dentin surfaces were bonded with One-Step Plus+total-etch; One-Step Plus+self-etch; One-Step+total-etch and One-Step+self-etch. Composite buildups were performed with Clearfil AP-X (Kuraray Medical). Following storage in distilled water at 37 degrees C for 24 h, the bonded specimens were serially sectioned into 0.7 mm-thick slabs and then trimmed to hour-glass shapes with a 1 mm2 cross-sectional area (n=20). Microtensile bond strengths were determined using the EZ-test (Shimadzu) at a cross-head speed of 1 mm/min. Data were analyzed using two-way ANOVA and Tukey's post hoc test. RESULTS: There were no significant differences in the muTBS between One-Step Plus and One-Step adhesives when they were used with the total-etch and self-etch techniques (p>0.05). However with the total-etch technique both adhesives yielded significantly higher bond strength values than the self-etch technique (p<0.001). CONCLUSION: The filled adhesive One-Step Plus did not show any beneficial effect than the unfilled adhesive One-Step on the muTBS to dentin with total-etch and self-etch techniques. Irrespective from the adhesive type, self-etch technique revealed lower bond strengths than the total-etch technique.  相似文献   

12.
OBJECTIVES: To evaluate the longevity of resin-dentin bonds of three adhesives using different storage media and specimen size. METHODS: Flat dentin surfaces from extracted human third molars were bonded with: a two-step etch-and-rinse self-priming adhesive (Single Bond), a two-step self-etching adhesive (Clearfil SE Bond), and a one-step self-etching adhesive (One-Up Bond F). Composite build-ups were constructed. The bonded teeth were stored under three conditions: dry, distilled water, or mineral oil. Half of the specimens were stored as intact bonded teeth (Indirect Exposure/IE). The other half were first sectioned into beams and stored under same conditions (Direct Exposure/DE). After storage periods of 24h, 3 months or 1 year, the intact teeth (IE) were sectioned into beams and both subgroups (DE and IE) were tested for microtensile bond strengths. Results were analyzed with multiple ANOVA and Student-Newman-Keuls tests. Fractographic analysis was performed by SEM. RESULTS: After 24h, Single Bond and Clearfil SE Bond performed equally and were superior to One-Up Bond F. After 3 months of DE to water storage, decreases in bond strengths were observed for Single Bond and One-Up Bond F, this decrease occurred for Clearfil SE Bond after 12 months of water storage. Bonded specimens aged in dry did not alter bond strengths over time. Bond strength increased when Single Bond was stored in mineral oil after 3 and 12 months. Micromorphological alterations were evident after water storage. SIGNIFICANCE: Although dentin bond strength of all the adhesives fell over time in DE, SE Bond fells the least.  相似文献   

13.
The purpose of this study was to assess bond strength of three self-etching and two total-etch adhesive systems bonded to primary tooth enamel and dentin. MATERIALS AND METHODS: Forty extracted primary human molars were selected and abraded in order to create flat buccal enamel and occlusal dentin surfaces. Teeth were assigned to one of the adhesive systems: Adper Scotch Bond Multi Purpose, Adper Single Bond 2, Adper Prompt L-Pop, Clearfil SE Bond and AdheSE. Immediately to adhesive application, a composite resin (Filtek Z250) block was built up. After 3 months of water storage, each sample was sequentially sectioned in order to obtain sticks with a square cross-sectional area of about 0.72 mm2. The specimens were fixed lengthways to a microtensile device and tested using a universal testing machine with a 50-N load cell at a crosshead speed of 0.5 mm/min. Microtensile bond strength values were recorded in MPa and compared by Analysis of Variance and the post hoc Tukey test (a = 0.05). RESULTS: In enamel, Clearfil SE Bond presented the highest values, followed by Adper Single Bond 2, AdheSE and Adper Scotch Bond Multi Purpose, without significant difference. The highest values in dentin were obtained with Adper Scotch Bond Multi Purpose and all other adhesives did not present significant different values from that, except Adper Prompt L-Pop that achieved the lowest bond strength in both substrates. Adper Scotch Bond Multi Purpose and Adper Single Bond 2 presented significantly lower values in enamel than in dentin although all other adhesives presented similar results in both substrates. CONCLUSIONS: contemporary adhesive systems present similar behaviors when bonded to primary teeth, with the exception of the one-step self-etching system; and self-etching systems can achieve bond strength values as good in enamel as in dentin of primary teeth.  相似文献   

14.
Filtek LS is a new composite resin restorative system with a unique, low-shrinking, silorane-based monomer matrix. The current study was conducted to compare the durability of the bond to dentin of the new silorane-based bonding agent, Filtek Silorane System Adhesive, to the gold standard methacrylate-based bonding agent, Clearfil SE Bond. Extracted human molar teeth were sectioned to expose dentin. Either Filtek Silorane System Adhesive with Filtek LS composite or Clearfil SE Bond with Clearfil Majesty Posterior composite was applied to the dentin according to the manufacturer's instructions. The composites were placed incrementally and sectioned perpendicular to the composite-tooth interface to obtain rectangular beams. The beams were stored for 24 hours, 6 months, or 12 months in distilled water and stressed in tension in a universal testing machine. Data were analyzed with a two-way ANOVA/Tukey test. The 24-hour microtensile bond strengths were significantly greater than the 6- and 12-month bond strengths. Overall, there was no significant difference in the microtensile bond strength to dentin between the Filtek Silorane System Adhesive and the Clearfil SE Bond adhesive bonding agents. After one year of water storage, the new silorane-based composite resin bonding agent performed as well as the methacrylate-based composite resin bonding agent.  相似文献   

15.
This in vitro study evaluated the microtensile bond strengths of sound versus caries-affected dentin using a self-etching adhesive system, Clearfil SE Bond, with or without additional acid pre-conditioning. Extracted human mandibular molars with occlusal caries extending halfway through the dentin were used. In the first group, the teeth were bonded with the self-etching adhesive Clearfil SE Bond according to the manufacturer's instructions. In the second group, prepared dentin surfaces were etched with 37% phosphoric acid prior to applying the same self-etching adhesive. After the bonding procedure, all specimens were built up with composite resin and stored in water for 24 hours. The teeth were serially sectioned vertically into 0.7-mm slabs and trimmed into an hourglass shape for measuring microtensile bond strength. Each specimen was attached to a Bencor device and stressed in tension at a crosshead speed of 1 mm/minute. Statistical analysis was performed using two-way ANOVA and the Tukey HSD test (p<0.05). The microtensile bond strengths of Clearfil SE Bond to sound dentin (32.9) were significantly higher than to caries-affected dentin (15.9). In the second group where acid etching was performed prior to applying Clearfil SE Bond, there were no statistically significant differences between the microtensile bond strengths of sound (19.2) and caries-affected dentin (16.3). While bond strengths to sound dentin were decreased by using additional acid etching prior to applying Clearfil SE Bond, this procedure revealed no statistically significant differences in bond strengths for the caries-affected dentin.  相似文献   

16.
目的:评价含丁香油酚的暂封剂氧化锌丁香油糊剂(zincoxide- eugenol ,ZOE)对全酸蚀/自酸蚀牙本质粘接系统微拉伸强度的影响。方法:选择因正畸拔除的完整、无龋前磨牙;两种全酸蚀牙本质粘接系统:AllBond 2和SingleBond ,两种自酸蚀牙本质粘接系统:ClearfilSEBond和iBond。实验组使用氧化锌丁香油糊剂;对照组牙本质表面不做任何处理;分别存储于3 7℃的蒸馏水中,一周后两组分别使用4种牙本质粘接系统,用微拉伸法测试粘接强度。在体视显微镜下观察断裂界面。结果:双因素方差分析使用ZOE对粘接强度有显著影响(P <0 .0 5 ) ,粘接剂的类型对粘接强度无显著性影响(P >0 .0 5 ) ,交互作用有统计学意义(P <0 .0 5 )。多重比较提示,AllBond 2和SingleBond的实验组和对照组无显著性差异,而ClearfilSEBond和iBond实验组的微拉伸强度明显低于对照组,有显著性差异。体视显微镜下观察断裂多发生在粘接剂内。结论:含丁香油酚的暂封剂氧化锌丁香油糊剂对全酸蚀系统的AllBond 2和SingleBond的粘接强度无影响,对自酸蚀系统的ClearfilSEBond和iBond有显著不利影响。  相似文献   

17.
PURPOSE: To evaluate the in vivo interface between one total-etch and two self-etching adhesives to dentin. METHODS: Two self-etching primers, SE Bond and Hybrid Bond and one total-etch adhesive, Admira Bond, were applied in vivo to flat dentin surfaces on human teeth scheduled for extraction. After adhesive application and curing, a thin layer of resin composite was applied and cured. The teeth were extracted immediately after adhesive application. All samples were split fractured along their long axes. Half of the samples were decalcified and deproteinized to permit visualization of the hybrid layer. The other halves were completely dissolved to observe the morphology of resin tags. RESULTS: The total-etch system Admira Bond showed a thick hybrid layer and long resin tags, while SE Bond showed very thin hybrid layer with short resin tags. The findings of Hybrid Bond were similar to that of Admira Bond.  相似文献   

18.
To compare the resin-dentin bond degradation of 10 contemporary etch-and-rinse adhesive systems after one year of water storage, 100 bovine incisors were randomly separated into 10 groups and their superficial coronal dentin was exposed. According to manufacturers' instructions, dentin surfaces were bonded with one of seven two-step etch-and-rinse adhesives or one of three three-step etch-and-rinse adhesives. Composite buildups were constructed incrementally. Restored teeth were sectioned to obtain sticks (0.5 mm2). The specimens were subjected to a microtensile bond strength test after storage in distilled water (at 37°C) for one year. Data (MPa) were analyzed using Kruskal-Wallis and Tukey's tests at α = 0.05. Of the adhesives tested, One Step, All Bond 2, and Optibond FL attained the highest bond strength to dentin after one year in water storage, while Magic Bond DE and Master Bond presented a high number of premature debonded flaws.  相似文献   

19.
目的:研究、比较三种脱敏剂对全酸蚀粘结剂牙本质粘结强度及其粘结界面形态的影响。方法:选择12个无龋损离体人磨牙,磨除牙合面釉质,用600目碳化硅砂纸在流水下预备出有统一玷污层的牙本质粘结面后,随机分为4组,分别用去离子水(对照组)和3种脱敏剂(Hybrid Coat、Gluma、极固宁)进行脱敏处理后,应用Single Bond 2在面粘结4 mm树脂。然后将每个牙垂直于粘结面切割出12个1.0 mm×1.0 mm×4.0 mm的粘结试件,分别在SEM下观察其粘结界面微观形态并进行微拉伸强度(μTBS)测试。结果:HybridCoat组粘结强度最高((14.81±3.87)MPa,随后依次为去离子水组(13.39±4.67)MPa、Gluma组(12.76±2.96)MPa和极固宁组(10.48±4.32)MPa,各组间两两比较,极固宁组明显低于其他3组(P﹤0.05),其他3组间相比均无显著性差异(P﹥0.05);Hybrid Coat组形成的树脂突大部分>35μm,长而密集;Gluma组形成的树脂突长7~35μm;极固宁组形成的树脂突长20~35μm,较稀疏。结论:Hybrid Coat和Gluma对全酸蚀粘结剂牙本质粘结强度无明显影响,而极固宁则明显降低其粘结强度。  相似文献   

20.
OBJECTIVES: The aim of this research was to determine the hybridization quality of adhesives to gingival cementum and close superficial dentin using both total-etch and self-etch, one-step and two-step adhesives in vitro. METHODS: Five adhesive systems were used and evaluated in this study; three kinds of two-step adhesives (total-etch--Single Bond and self-etch--Clearfil SE Bond and Clearfil Protect Bond) and two one-step adhesives (Clearfil S3 Bond, G Bond). Fifteen extracted intact human third molars were used in this study. A diagonal cut which was approximately 45 degrees to the long axis of the roots, with the initiating point located 2 mm below the buccal enamel-cementum junction and ascending towards the pulp chamber was prepared on each tooth. Flat cervical cementum and dentin surfaces were ground with wet 600-grit silicon carbide paper, and bonded with one of the adhesives and finished by applying a flowable resin composite. After 24 h storage at 37 degrees C in water, the bonded assemblies were sectioned into approximately 1mm thick slabs. Two central slabs from each tooth were chosen. One slab was totally demineralized in 0.5 M EDTA and the other was not demineralized and immersed into 50% (w/v) solution of ammoniacal silver nitrate for 24 h, and successively exposed to photodeveloping solution for 8 h. The specimens were then processed for TEM observation. Both the stained demineralized silver unchallenged and unstained non-demineralized silver challenged resin-cervical cementum/proximal superficial dentin interface were observed and evaluated under a transmission electron microscope. RESULTS: The nanoleakage pathway and extent vary among the different adhesives used and also between the resin-cementum interface and resin-dentin interface. Two-step self-etch adhesives showed better hybridization quality both in cementum and proximal superficial dentin as compared to those of two-step total-etch adhesive and one-step self-etch adhesives. SIGNIFICANCE: Two-step self-etch adhesives may provide a better sealing in cervical cementum and the proximal superficial dentin region.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号