共查询到20条相似文献,搜索用时 0 毫秒
1.
Myung-Sik Park Ju-Hong Lee Jong-Hyuk Park Dong-Hun Ham Yang-Keun Rhee 《The Journal of arthroplasty》2010
Most reports on the use of modular femoral stems during revision surgery have involved short follow-up periods. The authors evaluated the clinical and radiographic performance of 59 patients fitted with a distal fix modular stem. The average follow-up period was 8.2 years. Average Harris hip score was improved from 47 to 87.6. Of 19 patients with trochanteric osteotomy, 4 had a displaced greater trochanter. Re-revision was performed in 5 patients, and 3 of these were for subsidence (of these 3, subsidence was associated with dissociation of the coupling part in 1 and with osteotomy nonunion in other 2 [proximal component only]). Modular distally fixed femoral stems were found to offer intraoperative flexibility, but to suffer from subsidence and intraoperative greater trochanter and metaphyseal femoral fractures. 相似文献
2.
3.
Stefan R. Jibodh Ran Schwarzkopf Shawn G. Anthony Henrik Malchau Kyle E. Dempsey Daniel M. Estok II 《The Journal of arthroplasty》2013
Despite the increasing volume of revision total hip arthroplasty (THA) being performed in the United States, there are few studies reporting mid-term clinical and radiographic outcomes of modular fully porous-coated femoral stems. We retrospectively studied a consecutive series of patients who underwent revision THA with a modular extensively porous-coated femoral component at a single institution and by a single surgeon. The final study group included 54 hips (52 patients) followed for an average of 84 months. Ten-year survival rates with revision for any reason and revision for femoral loosening as endpoints were 94% and 100%, respectively. No complications regarding the modular junction were encountered. Of the 50 hips with adequate radiographs, all showed proximal ingrowth and 42 (84%) had both proximal and distal ingrowth. The modular, fully porous-coated femoral stem studied demonstrated excellent survivorship and bone ingrowth at mid-term follow up. 相似文献
4.
《The Journal of arthroplasty》2021,36(9):3269-3274
BackgroundIn revision total hip arthroplasty (THA) cases with preserved femoral metaphyseal bone, tapered proximally porous-coated “primary” femoral stems may be an option. The objective of this study was to compare outcomes of patients with Paprosky I or II femoral bone loss undergoing revision THA with either a primary metaphyseal-engaging cementless stem or a revision diaphyseal-engaging stem.MethodsThis was a retrospective analysis of 70 patients with Paprosky I or II femoral bone loss who underwent femoral revision. 35 patients who were revised using a primary cementless femoral stem were compared with 35 patients who underwent femoral revision using a revision diaphyseal-engaging stem. The groups were similar regarding age, gender, body mass index, and American Society of Anesthesiologists. Clinical and radiographic outcomes and complications were compared over an average follow-up of 2.9 years (SD 1.4).ResultsRevision THA was most commonly performed for periprosthetic joint infection (N = 27, 38.6%). The groups were similar with regards to Paprosky femoral classification (P = .56), length of stay (P = .68), discharge disposition (P = .461), operative time (P = .20), and complications (P = .164). There were no significant differences between primary and revision femoral stem subsidence (0.12 vs. 0.75 mm, P = .18), leg length discrepancy (2.3 vs. 4.05 mm, P = .37), and Hip Disability and Osteoarthritis Outcome Score Jr (73.1 [SD 21.1] vs. 62.8 [SD 21.7], P = .088). No patient underwent additional revision surgery involving the femoral component.ConclusionUse of modern primary cementless femoral stems is a viable option for revision hip arthroplasty in the setting of preserved proximal femoral metaphyseal bone. Outcomes are not inferior to those of revision stems and offer potential benefits. 相似文献
5.
《The Journal of arthroplasty》2023,38(5):855-861.e1
BackgroundCementless total hip arthroplasty (THA) femoral stems are the most commonly selected prostheses in the United States. Optimal stem geometry remains controversial with excellent survivorship reported for many designs. We compared cause-specific stem revision of single-wedge versus double-wedge designs from a multicenter US cohort.MethodsData from an integrated healthcare network’s total joint replacement registry were used to conduct a cohort study. Primary elective cementless THAs were identified (2001 to 2018). Implant exposure groups were classified by design geometry using the system proposed by Khanuja et al. Type 1 single-wedge (n = 11,082) and type 2 double-wedge (n = 32,380) designs were compared, and other design types were excluded; the final study cohort comprised 43,462 THAs. Cause-specific multivariable Cox regressions were used to evaluate risk for revision due to infection or aseptic reasons, including loosening, instability, periprosthetic fracture, or other reasons.ResultsAfter adjustment for covariates, a higher aseptic revision risk was observed for type 1 when compared to type 2 designs (hazard ratio = 1.91, 95% confidence interval = 1.33-2.75). When looking at specific revision reasons, revision for aseptic loosening (hazard ratio = 3.46, 95% confidence interval = 2.24-5.34) was higher for type 1 versus type 2 designs. No differences were found for septic revision, instability, periprosthetic fracture, or revisions for other reasons.ConclusionsType 1 single-wedge designs were found to have a higher risk of revision due to aseptic loosening relative to type 2 double-wedge designs. Femoral stem geometry should be considered when selecting a cementless femoral implant.Level of EvidenceLevel III. 相似文献
6.
《The Journal of arthroplasty》2022,37(1):89-96.e1
BackgroundWe sought to evaluate the cause-specific revision risk following hybrid (cemented stem mated to a cementless acetabular implant) vs cementless total hip arthroplasty (THA) in a US cohort.MethodsPrimary elective THA for osteoarthritis was identified using Kaiser Permanente’s Total Joint Replacement Registry (2001-2018). Multivariable Cox regression was used to evaluate cause-specific revision, including aseptic loosening, infection, instability, and periprosthetic fracture (PPF), for hybrid vs cementless THA. Analysis was stratified by age (<65, 65-74, and ≥75 years) and gender.ResultsThe study cohort comprised 88,830 THAs, including 4539 (5.1%) hybrid THAs. In stratified analysis, hybrid THA had a higher revision risk for loosening in females in all 3 age subgroups. A lower risk of revision for PPF was observed following hybrid THA in females aged ≥75 years. For females ≥75 years, cementless THA had an excess PPF risk of 0.9% while hybrid THA had an excess loosening risk of 0.2%, translating to a theoretical prevention of 10 PPF revisions but a price of 3 loosening revisions per 1000 hybrid THAs. No difference in revision risk was observed in males.ConclusionWe observed differences in cause-specific revision risks by method of stem fixation which depended upon patient age and gender. Although the trend toward all cementless fixation continue, there may be a role for hybrid fixation in females ≥75 years to mitigate risk for revision due to PPF at the potential cost of a slight increase in longer term aseptic loosening.Level of EvidenceLevel III. 相似文献
7.
《The Journal of arthroplasty》2023,38(5):903-908
BackgroundAs the number of primary total hip arthroplasty (THA) cases increase, so does the demand for revision operations. However, long-term follow-up data for revision THA is lacking.MethodsA retrospective review was completed of patients who underwent revision THA at a single institution between January 2002 and October 2007 using a cementless modular stem. Patient demographic, clinical, and radiographic data was collected. Preoperative and postoperative patient-reported outcome scores were compared at a minimum of fourteen-year follow-up.ResultsEighty-four patients (89 hips) with a median age of 69 years (range, 28 to 88) at operation were included. Indications for revision included aseptic loosening (84.2%), infection (12.4%), and periprosthetic fracture (3.4%). Twenty-two hips sustained at least 1 complication: intraoperative fracture (7.9%), dislocation (6.7%), prosthetic joint infection (4.5%), deep venous thrombosis (3.4%), and late periprosthetic fracture (2.2%). There were no modular junction complications. Eight patients underwent reoperations; only three involved the stem. Thirty-eight patients (45%) were deceased prior to final follow-up without known reoperations. Twenty-seven patients (32%) were lost to follow-up. Twenty-one patients (23%) were alive at minimum fourteen-year follow-up. Complete patient-reported outcomes were available for nineteen patients (range, 14 to 18.5 years of follow-up). Significant improvement was seen in UCLA activity, VR-12 physical, hip disability and osteoarthritis outcome score, joint replacement., and Harris Hip score pain and function scores.ConclusionChallenges of long-term follow-up include patient migration, an unwillingness to travel for re-examination, medical comorbidities, advanced age, and death. The cementless modular revision stem demonstrated long-term clinical success and remains a safe and reliable option for complex revision operations. 相似文献
8.
Jeffrey D. Stimac John Boles Natalie Parkes Alejandro Gonzalez Della Valle Friedrich Boettner Geoffrey H. Westrich 《The Journal of arthroplasty》2014
As the rate of revision total hip arthroplasty (THA) rises, attention must be paid to potential complications relating to bone loss, soft tissue deficiencies, and loss of tissue planes. Using modular femoral stems in revision surgery allows for varying amounts of bone loss in the proximal and distal femur while letting the surgeon adjust rotation, leg length, and offset. We retrospectively reviewed 125 patients that underwent revision THA with a modular femoral component system and had minimum 2 year follow-up. Ten patients required reoperations for infection, recurrent dislocation, or fracture treatment. There was no evidence of radiographic loosening or mechanical failure in the remaining patients. Modular femoral components provide excellent intraoperative flexibility and significant radiographic and clinical benefits as seen in this patient cohort. 相似文献
9.
After 2 to 7 years we reviewed 125 prosthetic hip arthroplasty stem revisions using a modular tapered stem with distal fixation. Median age of these patients was 68 (33-92) years. Baseline and follow-up data were registered prospectively according to the Danish Hip Arthroplasty Registry. Survival, free of any rerevision, was 94%. Harris Hip Score improved from average 44 to 85. Bony regeneration was an early and significant finding in most cases. Complications included 4 (3%) fractures intraoperatively and 8 (6%) dislocations, 4 (3%) deep infections, and 1 (1%) stem fracture. This modular taper system is very versatile, can be used in most femoral revision cases, and allows rapid bone remodeling. We did not find an increased number of complications compared to the literature. Further long-term follow-up, however, is essential. 相似文献
10.
Cortical Strut Allograft Support of Modular Femoral Junctions During Revision Total Hip Arthroplasty
Chin Tat Lim Derek F. Amanatullah James I. Huddleston Katherine L. Hwang William J. Maloney Stuart B. Goodman 《The Journal of arthroplasty》2017,32(5):1586-1592
Background
There is risk of junction failure when using modular femoral stems for revision total hip arthroplasty (THA), especially with loss of bone stock in the proximal femur. Using a cortical strut allograft may provide additional support of a modular femoral construct in revision THA.Methods
We reviewed prospectively gathered clinical and radiographic data for 28 revision THAs performed from 2004 to 2014 using cementless modular femoral components with cortical strut allograft applied to supplement proximal femoral bone loss: 5 (18%) were fluted taper designs and 23 (82%) were porous cylindrical designs All the patients had a Paprosky grade IIIA or greater femoral defect. The mean follow-up was 5.4 ± 3.9 years.Results
The Harris Hip Scores improved from 26 ± 10 points preoperatively to 71 ± 10 points at final follow-up (P < .001). The Western Ontario McMaster Universities Osteoarthritis Index scores improved from 45 ± 12 points preoperatively to 76 ± 12 points at final follow-up (P < .001). Eighty-nine percent (25 hips) of all revision or conversion THAs were in place at final follow-up. Three (11%) patients underwent reoperations, 2 for infection and 1 for periprosthetic fracture. There was no statistical significant change in femoral component alignment (P = .161) at final follow-up. Mean subsidence was 1.8 ± 1.3 mm at final follow-up. Femoral diameter increased from initial postoperative imaging to final follow-up imaging by a mean of 9.1 ± 5.1 mm (P < .001) and cortical width increased by a mean of 4.5 ± 2.2 mm (P < .001). Twenty-seven hips (96%) achieved union between the cortical strut allograft and the host femur.Conclusion
The use of a modular femoral stem in a compromised femur with a supplementary cortical strut allgraft is safe and provides satisfactory clinical and radiological outcomes. 相似文献11.
Sureshan Sivananthan Chin-Tat Lim Rapeepat Narkbunnam Alex Sox-Harris James I. Huddleston Stuart B. Goodman 《The Journal of arthroplasty》2017,32(4):1245-1249
Background
Modular femoral stem provides flexibility in femoral reconstruction, ensuring improved “fit and fill”. However, there are risks of junction failure and corrosion, as well as cost concerns in the use of modular femoral stems.Methods
We reviewed prospectively-gathered clinical and radiographic data on revision total hip arthroplasties (THAs) performed from 2001-2007 using modular, cementless femoral component performed by the 2 senior authors. Patients with a minimum follow-up of 7 years were included in this study.Results
Sixty-four patients (68 hips) with a median age of 68 ± 14 years (range 40-92 years) at revision THA were included. The median follow-up was 11.0 ± 1.8 years (range 7-14). Harris hip score, femoral stem subsidence, and stem osseointegration were recorded. The Harris hip score improved from an average of 38.1-80.1 (P < .01). Five hips had one or more dislocations. Seven patients underwent reoperations, 3 of which did not involve the stem. Four stems required revision because of infection, recurrent dislocation, or suboptimal implant position. Survival rates for any reasons and revision for femoral stems were 90% and 94%, respectively, at the most recent follow-up. Four stems subsided more than 5 mm, but established stable osseointegration thereafter. Seven nonloose stems (10.2%) demonstrated radiolucent lines in Gruen zones 1 and 7. No complications regarding the modular junction were encountered.Conclusion
Modular, cementless, extensively porous-coated femoral components have demonstrated intermediate-term clinical and radiographic success. Initial distal intramedullary fixation ensures stability, and proximal modularity further maximizes fit and fill. 相似文献12.
《The Journal of arthroplasty》2020,35(12):3697-3702
BackgroundThe use of an extensively porous-coated uncemented cobalt-chrome monoblock femoral stem for revision total hip arthroplasty (THA) is well established with excellent mid-term results. The aim of this study is to report the long-term survivorship of these implants in femoral stem revisions.MethodsThis is a long-term retrospective review of prospectively collected data of 55 femoral stem revisions in 55 patients using a contemporary, cementless extensively porous-coated cobalt-chrome monoblock stem. All patients between 2001 and 2006 who underwent first time femoral stem revision with a contemporary, cementless extensively porous-coated cobalt-chrome monoblock stem were included. Harris Hip Score, Western Ontario and McMaster Universities Index, and University of California Los Angeles activity scores were recorded preoperatively and at latest follow-up. Radiographs were analyzed for evidence of loosening, subsidence, osteolysis, and bony union. This study included 55 patients, comprising of 36 females (66%) and 19 males (34%) with a mean age of 66.4 ± 9.3 years at the time of surgery. The mean time interval from index procedure was 9.8 ± 2.9 years. Mean time from revision THA to final follow-up was 13.2 ± 2.17 years with a minimum of 10 years of follow-up.ResultsIndications for revision included aseptic loosening (33), prosthetic joint infection (13), and periprosthetic fracture (10). Significant improvement in Harris Hip Score (85.1 ± 1.77 vs 51.8 ± 2.3, P < .001), Western Ontario and McMaster Universities Index (17.6 ± 0.77 vs 33.3 ± 0.8, P < .001), and University of California Los Angeles (5.25 ± 0.2 vs 2.7 ± 0.36, P < .001) scores were found at latest follow-up compared to preoperative. Fifty-four patients (98%) achieved stable bony ingrowth on radiographic analysis. All 10 patients treated for periprosthetic fractures achieved bony union of their fractures. Two patients suffered intraoperative periprosthetic fractures and were treated with a cable-plating system. There were no mechanical failures and no femoral stem re-revisions. One patient was diagnosed with a deep infection and was treated with chronic suppressive antibiotic therapy due to significant medical comorbidities.ConclusionRevision of the femoral component with a contemporary extensively porous-coated cobalt-chrome femoral stem has excellent functional outcomes, radiographic outcomes, and long-term survivorship with minimal complications. 相似文献
13.
《The Journal of arthroplasty》2023,38(4):751-756
BackgroundRecent studies indicate a decreased risk of periprosthetic femoral fractures (PFFs) in cementless total hip arthroplasty (THA) for short compared to straight stems. However, the results are still inconclusive. Therefore, we retrospectively investigated the rate of PFFs within the first year between cementless short and straight stem THA.MethodsA 1:1 propensity score matching of 3,053 THAs was performed. Two groups including 1,147 short stem THAs implanted through a minimally invasive antero-lateral approach and 1,147 straight stem THAs implanted through a transgluteal Hardinge approach were matched. The rates of PFFs and fracture patterns were compared between both stem types. Risk factors for PFFs were analyzed by multivariate regression analyses.ResultsThe overall rate of PFFs was 1.7% in short stem THA and 3.2% in straight stem THA (P = .015). Postoperatively detected Vancouver A fractures occurred significantly more often in straight stem THA (P = .002), while the occurrence Vancouver B fractures did not differ significantly (P = .563). The risk of PFFs was significantly increased for women in straight stem THA (Odds ratio (OR) 2.620; Confidence Interval (CI) 1.172-5.856; P = .019). Increasing age showed a significantly increased odds ratio in short stem (OR 1.103; CI 1.041-1.169, P < .001) and straight stem THA (OR 1.057; CI 1.014-1.101, P = .008).ConclusionShort stem THA reduces Vancouver Type A PFFs in the trochanteric region compared to straight stem THA, while Vancouver Type B fractures are comparable. Increasing age is a significant risk factor for both stem types, while the risk for PFFs in women was only significantly increased in the straight stem group. 相似文献
14.
María José Sangüesa-Nebot Francisco Cabanes SorianoRafael Fernández Gabarda MD Carlos Valverde Mordt PhD 《The Journal of arthroplasty》2010
We describe a case of a fractured femoral component in a hydroxyapatite-coated cementless total hip arthroplasty that was revised using a prosthesis with circumferential proximal metaphyseal support and a lateral flare, with a short femoral stem. This type of prosthesis allows for revision, thus, avoiding the removal of the distal part of the previous prosthesis well bonded to the bone. This makes the revision arthroplasty easier and the patient's recovery quicker. 相似文献
15.
A prospective study of 15 patients was designed to examine whether the modular cementless revision stem (Revitan curved; Zimmer GmbH, Winterthur, Switzerland) is suitable for stem revisions with a defective isthmus when distal interlocking screws are also used for fixation. During a follow-up period of 35.4 ± 11.4 months (24-70 months), there was one stem loosening with screw breakage in a case of a stem that was too thin. According to Engh et al, bony ingrowth fixation of the stem occurred in 12 cases and stable fibrous fixation in 2 cases. The Harris Hip Score rose continuously from 44.7 ± 12.9 points preoperatively to 75 ± 10 points at 24 months. This concept of additional stem fixation with distal interlocking screws represents a useful treatment option for revision arthroplasty in rare cases of a defective isthmus. 相似文献
16.
Michael D. Hellman Sean M. Kearns Daniel D. Bohl Bryan D. Haughom Brett R. Levine 《The Journal of arthroplasty》2017,32(12):3698-3703
Background
In revision total hip arthroplasty (THA), proximal femoral bone loss creates a challenge of achieving adequate stem fixation. The purpose of this study was to examine the outcomes of a monoblock, splined, tapered femoral stem in revision THA.Methods
Outcomes of revision THA using a nonmodular, splined, tapered femoral stem from a single surgeon were reviewed. With a minimum of 2-year follow-up, there were 68 cases (67 patients). Paprosky classification was 3A or greater in 85% of the cases. Preoperative and postoperative Harris Hip Scores (HHS), radiographic subsidence and osseointegration, limb length discrepancy, complications, and reoperations were analyzed.Results
The Harris Hip Score improved from 37.4 ± SD 19.4 preoperatively to 64.6 ± SD 21.8 at final follow-up (P < .001). There were 16 revision procedures—8 for septic indications and 8 for aseptic indications. Subsidence occurred at a rate of 3.0% and dislocation at 7.4%. Limb length discrepancy of more than 1 cm after revision was noted in 13.6% of patients. Bone ingrowth was observed in all but 4 patients (94.1%). At 4-year follow-up, Kaplan-Meier estimated survival was 72.9% (95% confidence interval [CI] 57.0-83.8) for all causes of revision, 86.6% (95% CI 72.0-93.9) for all aseptic revision, and 95.5% (95% CI 86.8-98.5) for aseptic femoral revision.Conclusion
Although complications were significant, revision for femoral aseptic loosening occurred in only 3 patients. Given the ability of this monoblock splined tapered stem to adequately provide fixation during complex revision THA, it remains a viable option in the setting of substantial femoral bone defects. 相似文献17.
Yoshihide Nakamura Hiromasa Mitsui Akira Kikuchi Satoshi Toh Hiroshi Katano 《The Journal of arthroplasty》2011,26(1):77-81
We performed total hip arthroplasty using an anatomic medullary locking cementless stem for small-physique patients from 1988 to 1995. We conducted a retrospective study of 50 joints in 44 cases, including 40 developmentally dysplastic hips followed for 12 to 20 years (average, 15.1 years). Average height and body weight were 152 cm and 56 kg (5.0 ft and 124 lb), respectively, with an average body mass index of 24.2. Twelve joints (24%) were revised for acetabular-sided failures. Forty-eight stems (96%) showed bone ingrowth fixation, and there were no unstable stems. The simple cylindrical shape of the distal portion of the AML stem was less affected by deformity of the proximal femur of developmental dysplasia of the hip in patients with a small physique, and both clinically and radiologically good results were confirmed at long-term follow-up. 相似文献
18.
Kyoung Ho Moon Joon Soon Kang Sang Hyup Lee Sae Rom Jung 《Clinics in Orthopedic Surgery》2009,1(2):105-109
Background
To determine the benefit of an extensively porous coated femoral stem in patients receiving revision total hip arthroplasty.Methods
This study reviewed the results of 35 patients who received a revision total hip arthroplasty with extensively porous coated femoral stem between August, 1996, and December, 2002. The mean follow-up period was 77.5 months. The clinical and radiological results were evaluated by the Harris hip score and serial roentgenographic findings.Results
The preoperative and postoperative Harris hip score was 68.3 and 92.5, respectively. Radiographically, none of the acetabular components showed any evidence of migration, tilt, rotation, or shedding of metal particles. In addition, none of the femoral components showed evidence of subsidence, pedestal, or shedding of metal particles. Twenty-two hips had a mild stress shield and 2 hips had a moderate stress shield. The perioperative complications encountered were deep vein thrombosis (1 case), mild heterotopic ossification (4 cases), intraoperative periprosthetic fractures (1 case), and nonunion of the trochanteric osteotomy site (2 cases).Conclusions
Extensively porous coated femoral stems and acetabular components produce excellent clinical and radiological results in revision total hip arthroplasty. 相似文献19.
Jin-Ho Cho Jonathan P. Garino Suk-Kyu Choo Kye-Young Han Jung-Hoon Kim Hyoung-Keun Oh 《Clinics in Orthopedic Surgery》2010,2(4):214-220
Background
Aseptic loosening of cemented hip prostheses is recognized as a long-term problem, and especially in males and younger patients. Much energy has been focused on developing new prostheses that are designed for cementless fixation. We evaluated the performance of and periprosthetic bone response to a tapered, titanium, hydroxyapatite (HA)-coated femoral hip prosthesis at a minimum of 7 years of follow-up after treatment with primary total hip arthroplasty.Methods
Seventy-eight patients and 86 hips were included in the study. There were 35 men and 43 women; the mean age at the time of the operation was 59 years (range, 41 to 81 years). We used a tapered, titanium (Ti6Al4V), HA-coated femoral implant. We evaluated the patients at a minimum of 7 years of follow-up after treatment with primary total hip arthroplasty. Clinical evaluation was performed using the scoring system and the hip scores were assigned according to the level of pain, the functional status and the range of motion. The patients who refused to return, but who did forward X-rays for review after being contacted were questioned by phone about the functional status of their hip. Radiographic follow-up was performed at six weeks, at three, six and twelve months and yearly thereafter. All the available radiographs were collected and assessed for implant stability, subsidence, osseointegration, osteolysis, stress shielding and evidence of periprosthetic lucency.Results
Eighty-six hips (78 patients) were available for review at follow-up of greater than 7 years. In 11 of the 86 cases, acetabular failure required revision of the acetabular component, but the femoral stem survived and it was available for long-term evaluation. The radiographs were obtained at 7-year follow-up for another 20 hips, but the patients would not come in for the 7-year clinical evaluation. Therefore, a phone interview was conducted to assess any change in the functional status at a minimum of 7 years.Conclusions
The mechanical fixation of a tapered, titanium, HA-coated femoral implant was excellent in this study. This femoral design provided reliable osseointegration that was durable at a mean of 7 years follow-up. 相似文献20.
《The Journal of arthroplasty》2023,38(5):880-885
BackgroundThe purpose of the present study was to update and report clinical outcomes and survival of primary total hip arthroplasty using a cementless double-tapered titanium fully hydroxyapatite-coated stem at a follow-up > 30 years.MethodsThe outcomes of this series of 347 primary total hip arthroplasties were already published at a follow-up > 25 years, during which only 12 stems were revised. Since then, there were two additional stem revisions, bringing the total to 14 stem revisions (all of which also required cup revision). Patients still living with the original stem were assessed using the modified Harris Hip Score and patient satisfaction (very satisfied, satisfied, dissatisfied, and very dissatisfied). Revision incidence was calculated using the Kaplan-Meier (KM) method and Cumulative Incidence Function (CIF) at 35 years.ResultsAt a mean follow-up of 33 years (range, 31 to 35 years), 32 patients (34 hips) were still living with the original stem. Their mean modified Harris Hip Score was 86 points (range, 46 to 100) and all patients (100%) were very satisfied or satisfied with surgery. The revision incidence at 35 years considering (a) stem revision for any reason was 9.5% using KM and 4.5% using CIF; (b) stem revision for aseptic loosening was 3.1% using KM and 2.1% using CIF; and (c) reoperation or revision of any component for any reason was 45.3% using KM and 26.3% using CIF.ConclusionThe present study has demonstrated excellent survival at 35 years for a cementless double-tapered titanium fully hydroxyapatite-coated stem.Level of EvidenceLevel IV, Retrospective cohort study. 相似文献