首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
While the number of revision total knee arthoplasties (TKA) performed in the United States continues to rise annually, controversy exists whether intramedullary stems should be cemented or press-fit. Retrospective analysis of midterm survivorship rate of revision TKA using hybrid stem fixation in 119 patients was performed. Revision was performed predominantly for aseptic loosening (78) and infections (28). Average follow-up was 62 months (range, 46–80). Knee Society Pain and Function scores improved from 39 and 58 to 68 and 79 (P < .05). Fifty-eight tibial offsets and 28 femoral offsets were utilized. Three knees (2.5%) required revision without any cases of aseptic loosening. Radiographic complete or progressively advanced (> 2 mm) radiolucent lines were not observed in any patient. At mid-term follow-up, revision hybrid TKA provides excellent fixation with extremely low rates of aseptic loosening and avoids the inherent complications of extensive intramedullary cement.  相似文献   

2.
Between February1999 and April 2006, 25 patients (28 knees) underwent a TKA by a single surgeon. At an average final follow-up of 7 ± 2 years (range, 3–10 years), 34 (100%) of 34 fully porous stems had achieved bone ingrowth. However, one case (3%) had a component loosening due to the de-bonding of sheets of beads from the stem. The remaining cases remained well fixed. Three well-fixed stems in 2 patients failed from deep infection. There was one reoperation required for a femoral periprosthetic fracture. Our 10-year experience shows that fully porous-coated stems reliably achieve durable fixation in complex primary and revision TKA allowing the surgeon to bypass large bone defects and gain fixation in diaphyseal bone.  相似文献   

3.

Background

Aseptic loosening continues to be a short- and long-term complication for patients with cemented TKAs. Most studies to this point have evaluated tibial component fixation via radiographic changes at the implant-bone interface and quantification of component migration; direct assessment of morphologic features of the interface from functioning TKAs may provide new information regarding how TKAs function and are fixed to bone.

Questions/purposes

In a postmortem retrieval study, we asked: (1) What are the morphologic features at the cement-trabecular bone interface in retrieved tibial components? (2) Do constructs with greater time in service have less cement-trabecular bone interlock? (3) Do constructs with more estimated initial interlock sustain more interlock with in vivo service?

Methods

Fourteen postmortem retrieved tibial components with time in service from 0 to 20 years were sectioned and imaged at high resolution, and the current contact fraction, estimated initial interdigitation depth, current interdigitation depth, and loss of interdigitation depth were quantified at the cement-bone interface. Estimated initial interdigitation depth was calculated from the initial mold shape of the cement mantle that forms around the individual trabeculae at the time of surgery. Loss of interdigitation depth was the difference between the initial and current interdigitation depth.

Results

There was resorption of trabeculae that initially interlocked with the cement in the postmortem retrievals as evidenced by the differences between current interdigitation and the estimated original interdigitation. The current contact fraction (r2 = 0.54; p = 0.0027) and current interdigitation depth (r2 = 0.33; p = 0.033) were less for constructs with longer time in service. The current contact fraction for implants with 10 or more years in service (6.2%; 95% CI, 4.7%–7.7%) was much less than implants with less than 10 years in service (22.9%; 95% CI, 8.9%–37%). Similarly, the current interdigitation depth for implants with 10 or more years in service (0.4 mm; 95% CI, 0.27–0.53 mm) was much less than implants with less than 10 years in service (1.13 mm; 95% CI, 0.48–1.78 mm). The loss of interdigitation depth had a strong positive relationship with time in service (r2 = 0.74; p < 0.001). Using a two-parameter regression model, constructs with more initial interdigitation depth had greater current interdigitation depth (p = 0.011), but constructs with more time in service also had less current interdigitation depth (p = 0.008).

Conclusions

The cement-trabecular bone interlock obtained initially appears to diminish with time with in vivo service by resorption of the trabeculae in the cement interlock region.

Clinical Relevance

Our study supports the surgical concept of obtaining sufficient initial cement interlock (approximately 3 mm), with the acknowledgment that there will be loss of interlock with time with in vivo service.  相似文献   

4.
Below knee amputation protects the ipsilateral knee from osteoarthritis and overloads the contralateral knee predisposing it to symptomatic osteoarthritis. We retrospectively reviewed 13 primary total knee arthroplasty (TKAs) in 12 patients with a prior lower extremity amputation. Twelve TKAs were performed on the contralateral side of the amputated limb while only one TKA was performed on the ipsilateral side. The average clinical follow-up was 6.8 ± 4.8 years. Knee Society Scores improved from 30.4 ± 11.8 to 88.5 ± 4.2 after TKA with a prior contralateral amputation. Three (23.1%) patients with TKA after contralateral amputation had aseptic loosening of the tibial component. Patients experience clinically significant improvement with TKA after lower extremity amputation. Augmentation of tibial fixation with a stem may be advisable during TKA after contralateral amputation.  相似文献   

5.
The purpose of this study was to evaluate the efficacy of an uncemented tapered femoral component in obese patients at a mean follow-up of 23 years. We retrospectively reviewed 119 consecutive uncemented total hip arthroplasties in 105 obese patients using a tapered femoral component between 1983 and 1987. The mean body mass index of these patients was 34 (range 30–47). Complete clinical and radiographic follow-up was obtained on the 55 hips in 47 patients who survived a minimum of 18 years (range 18–27 years). Three femoral components (6%) have been revised, none for aseptic loosening. One was loose by radiographic criteria. These results demonstrate that an uncemented tapered stem can provide excellent fixation in obese patients out to 27 years.  相似文献   

6.

Background

Metaphyseal fixation has promising early results in providing component stability and fixation in revision total knee arthroplasty (TKA). However, there are limited studies on midterm results of metaphyseal sleeves. We analyzed complications, rerevisions, and survivorship free of revision for aseptic loosening of metaphyseal sleeves in revision TKA.

Methods

Two hundred eighty patients with 393 metaphyseal sleeves (144 femoral, 249 tibial) implanted during revision TKA from 2006-2014 were reviewed. Sleeves were most commonly cemented (55% femoral, 72% tibial). Mean follow-up was 3 years, mean age was 66 years, and mean body mass index was 34 kg/m2. Indications for revision TKA included 2-stage reimplantation for deep infection (37%), aseptic loosening of the tibia (14%), femur (12%), or both components (9%), and instability (14%).

Results

There was a 12% rate of perioperative complications, most commonly intraoperative fracture (6.5%). Eight sleeves (2.5%) required removal: 6 (2%) during component resection for deep infection (all were well-fixed at removal) as well as 1 (0.8%) femoral sleeve and 1 (0.8%) tibial sleeve for aseptic loosening. Five-year survivorship free of revision for aseptic loosening was 96% and 99.5% for femoral and tibial sleeves, respectively. Level of constraint, bone loss, sleeve and/or stem fixation, and revision indication did not significantly affect outcomes.

Conclusion

Metaphyseal sleeve fixation to enhance component stability during revision TKA has a 5-year survivorship free of revision for aseptic loosening of 96% and 99.5% in femoral and tibial sleeves, respectively. Both cemented and cementless sleeve fixation provides reliable durability at intermediate follow-up.  相似文献   

7.
Between August 1985 and December 1987, a total of 303 total hip arthroplasties were performed in 275 patients using the Saint Nabor press-fit acetabular component. Radiographic evaluations were performed at an average of 18.1 years for 95 hips in 86 patients. Migration analyses of the femoral and acetabular components were also performed. Seventeen patients had early postoperative complications: aseptic loosening in 1 patient, luxation in 16 patients. Twenty-five patients (25 hips) had late postoperative complications involving aseptic loosening: 21 femoral components, 2 acetabular components, and 2 cases of both components. The average acetabular component migration in the horizontal direction was 1.71 mm and was 0.31 mm in the vertical direction. The Kaplan–Meier survival rate of the acetabular component at 19 years was 95%.  相似文献   

8.
A consecutive, non-selective cohort of 83 (77 patients) cemented total hip arthroplasty revisions using contemporary cementing techniques was analyzed at a minimum of 20 years following the index procedure. No patients were lost to follow-up. The average age at revision was 62.4 years (23 to 89). Twenty-two hips (26.5%) had had a reoperation, eighteen (21.7%) for aseptic loosening, 3 (3.6%) for femoral prosthesis fracture and 1 (1.2%) for dislocation. The incidence of re-revision for aseptic femoral loosening was 7.5% and for aseptic acetabular loosening was 21.7%. These results confirm that cemented femoral revision using improved cementing techniques is a durable option in revision hip surgery. In contrast to this, THA revisions using a cemented acetabular component have been less durable at this length of follow-up.  相似文献   

9.
A prospective study of a hybrid total knee arthroplasty (TKA) with an uncemented femoral component and cemented tibial and patellar components was performed to combine the advantage of a press-fit femur while avoiding the problems in uncemented tibial and patellar implants. A total of 329 posterior cruciate-preserving TKA were studied at an average of 4.7 years after surgery: 84% of the knees had at most mild or occasional pain, 68% had good or excellent knee scores, and 62% could walk more than 1000 m. The function scores were 40% good or excellent in this collective, with an average age of 69.4 years at surgery. The component position and alignment were biomechanically correct. Radiolucent lines were observed regularly at the edges of the tibial and femoral components. There were no revisions for aseptic loosening. Hybrid TKA provides good results comparable to cemented TKA.  相似文献   

10.
Metal on metal bearings were reintroduced into the United States for use in total hip arthroplasty approximately a decade ago. We evaluated a consecutive series cohort of 148 patients with 169 hips who underwent THR using a metal on metal bearing surface with a modular acetabular shell that had fixation augmentation with dome screws. At 3 to 8 year follow-up, average 4.7 years, only one component was revised (for femoral loosening). 3 hips demonstrated proximal femoral osteolysis and 3 hips demonstrated pelvic osteolysis. The average follow-up Harris Hip Score was 94 (range, 57–100). Although the results have been excellent, we continue to closely monitor these hips for any long term failures, or concerns.  相似文献   

11.
《The Journal of arthroplasty》2020,35(8):2090-2096
BackgroundThe type of total knee arthroplasty (TKA) fixation (cemented or uncemented) is still subject to debate. The aim of this study is to assess the survival rate, clinical outcomes, and radiological results of TKA according to the fixation type.MethodsA total of 130 patients were randomly assigned to either the cement group (cemented femoral and tibial implants) or the hybrid group (cemented tibial implant, uncemented femoral implant). The inclusion criteria were patients between 50 and 90 years old who underwent primary TKA for osteoarthritis between 2004 and 2005 without a history of open knee surgery. Revisions and complications were reported, as well as clinical scores and radiological signs of loosening.ResultsOne hundred eighteen patients had complete data at 10 years of minimum follow-up (59 in each group). The mean age was 72 years old. The mean follow-up was 13 years. The survival rate was 98% at 13 years in both groups (1 aseptic loosening at 2 years in the cement group, 1 septic loosening in the hybrid group). The complication rate in the cement group was 8.5% (n = 5) vs 12.1% (n = 7) in the hybrid group (P = .8). The clinical results were not significantly different. In the cement group, 25% of patients (n = 15) had radiolucent lines at 10 years. In the hybrid group, 33% of patients had bone transparencies, not evolving or symptomatic.ConclusionAt a minimum follow-up of 10 years, there were no significant differences between cemented TKA and hybrid TKA for the survivorship, the complication rate, the clinical scores, or the radiological signs of loosening.Level of EvidenceI.  相似文献   

12.
We evaluated 106 knees that underwent primary total knee arthroplasty (TKA) with the navigation-assisted gap balancing technique using an e.-motion cruciate retaining floating platform (FP) mobile-bearing prosthesis to prospectively assess the survival of the e.-motion FP system after a minimum follow-up of 4 years. There was no evidence of any complications, including dissociation or breakage of the polyethylene liner or component loosening at last follow up (5.1 ± 0.6 years). Four knees, however, required re-operation, three for distal femoral fracture, and one for infection. The estimated 5-year prosthesis survival rates without revision for any reason and for prosthesis-associated problems were 96.2% and 100%, respectively. The e.-motion floating platform, with a cruciate retaining design under navigation guidance, demonstrated excellent clinical results and 5-year survival rate.  相似文献   

13.
Ninety-five hips with cementless wedge-shaped tapered CLS stem were evaluated with a mean duration of 12.7 years (range, 10.7–17.3 years). All patients were young and diagnosed with osteonecrosis of the femoral head. The Harris hip score was 92 at the latest follow-up. A subsidence greater than 3 mm was found in 3 hips (3.2%). Focal femoral osteolysis was found in 12 hips (12.6%). Endosteal bone formation and bony pedestal were observed in 94 hips (98.9%) and in 26 hips (27.4%), respectively. With revision for stem loosening as the end point, the survivorship showed 98.9% (95% CI, range 96.9%–100%) at 13 years. Stem alignment and proximal femur morphology did not influence loosening of the stem (p > 0.05).  相似文献   

14.
Median 14-year follow-up (mean 11.8 years) of a cemented primary posterior cruciate-retaining total knee arthroplasty (TKA) utilizing the Press-Fit Condylar (PFC) Sigma design was evaluated in 77 patients (79 TKA). Follow-up assessment included implant survivorship, x-rays, Knee Society rating system, and clinical evaluation. Radiographic analysis demonstrated minor non-progressive osteolysis in 40% (10/25) knees. Two revisions, one for instability at 4 years and one for polyethylene wear at 10 years were performed. Survivorship of the PFC Sigma knee implant was 97% using revision for any reason and 100% using aseptic loosening as endpoints. The PFC Sigma had excellent survivorship at 14 years, the longest clinical follow-up reported.  相似文献   

15.
Hybrid total knee arthroplasty (TKA) (uncemented femur with cemented tibia and patella) was introduced in the late 1980s to gain the theoretical advantage of durable cementless femoral fixation while avoiding the problems noted with cementless tibial fixation. From December 1992 to July 2000, 215 patients (235 knees) who underwent hybrid TKA were enrolled in this study. Five types of prosthesis (AGC, Maxim, LCS-M, LCS-APG, and Scorpio) were used. Revision rate for aseptic loosening was 16 (6.8%) of 235 knees. At 10 and 15 years, survivorship with tibial or femoral revision as the end point was 0.95 and 0.92, respectively. Hybrid TKA provides durable fixation with clinical and radiographic performance at minimum 10 years comparable with cemented series.  相似文献   

16.
《The Journal of arthroplasty》2020,35(8):2097-2100
BackgroundObese and morbidly obese patients undergoing primary total knee arthroplasty (TKA) place significant stress at the bone-cement-implant interface over the life of the patient. The purpose of this study is to evaluate results of cemented, posterior-stabilized TKA in obese and morbidly obese patients at an average follow-up of 10 years.MethodsRetrospective study of 181 patients who had a cemented, posterior-stabilized TKA between 2000 and 2013 with body mass index >35 at the time of surgery was conducted. Clinical data and radiographs were evaluated along with survivorship, complications, and revisions. Minimum follow-up was 5 years with an average follow-up of 10 years.ResultsThere were 135 women and 46 men in the study, with mean age of 60.2 years (range 43-80), mean body mass index of 42.0 (range 35.1-66.1), and an average follow-up of 10 years (range 5-18). There were a total of 39 failures (22%) that underwent revision TKA surgery with mean time to revision of 8 years. Failures included 25 (14%) cases of aseptic loosening; 9 (5%) polyethylene wear; 2 (1%) prosthetic joint infection; and 3 additional revisions for instability, pain, and stiffness. There were a total of 11 cases of isolated tibial component loosening and 13 for both tibial and femoral loosening. Survivorship at 15 years with aseptic loosening as the endpoint was 86.7%, and for all causes 79.6% at 15 years.ConclusionAseptic loosening is the leading cause of failure following TKA in obese and morbidly obese patients with decreasing survivorship from 96.1% to 91.2% and 86.7% at 5, 10, and 15 years, respectively.  相似文献   

17.
ObjectiveHybrid fixation is one alternative to full-cemented fixation in total knee arthroplasty (TKA) with theoretical advantages. Hybrid fixation may offer the advantages of cementless femoral fixation, while also avoiding the problem of tibial loosening in full-cementless TKA. The purpose of the study is to determine whether hybrid TKA may perform comparably to or better than full-cemented and full-cementless TKA.MethodsWe searched the MEDLINE, EMBASE and Cochrane Library databases through September 2018 for randomized controlled trials and observational studies comparing outcomes of hybrid versus full-cemented or full-cementless fixation techniques. Outcomes of interest included aseptic loosening, overall reoperation rate, infection, radiolucent lines and operating time. Data were pooled with the Mantel–Haenszel random effects model.ResultsWe included 14 studies with follow-up ranging from 2.7 to 9.6 years in our quantitative analysis, of which 7 studies compared hybrid fixation with full-cemented TKA and another 7 compared hybrid fixation with full-cementless TKA. Combined data revealed that the hybrid fixation group had a similar rate of aseptic loosening compared with cemented (P = 0.19) and cementless (P = 0.49) groups. There was no difference with respect to other outcomes, including overall reoperation rate, infection, radiolucent lines and operating time between groups.ConclusionHybrid, cementless and cemented TKAs have comparable mid-term results as it pertains to aseptic loosening, overall reoperation, infection, radiolucent lines and operating time. Further comparative studies are needed to investigate these potential effects over the long-term.  相似文献   

18.
BackgroundHighly porous metaphyseal cones have been introduced to restore metaphyseal integrity for improved cement interdigitation to achieve durable fixation in revision total knee arthroplasty (TKA). The purpose of this study is to review the survivorship, clinical results, and complications of revision TKA using highly porous 3-dimensionally printed titanium metaphyseal cones.MethodsThis is a review of 62 revision TKAs using metaphyseal tibial cones, with 15 cases utilizing both tibial and femoral cones. The mean age of the patients was 66 years (range 32-84) who had a mean follow-up of 27 months (range 24-34). There were 38 women and 24 men, who had a mean body mass index of 33 (range 18.3-62).ResultsRevision-free survival of the cones was 90.2%. If infection was excluded, survivorship was 100%. There were no cases of aseptic loosening. The mean Knee Society Score improved from 51 points preoperatively to 80 points at the time of latest follow-up. The mean Knee Society Functional Score improved from 48 points preoperatively to 68 points. A total of 15 of the 62 patients (24%) required additional surgery: 10 (16%) for infection, 3 (5%) for contracture, 1 for patellar subluxation, and 1 for quadriceps tendon rupture.ConclusionMetaphyseal fixation is important for survivorship in revision TKA which can be challenging due to cancellous and structural bone loss encountered at the time of revision. Prosthetic joint infection continues to be the leading cause of failure in revision TKA. The use of highly porous titanium metaphyseal cones produced from 3-dimensionally printed technology used in this study demonstrated excellent short-term results with no cases of aseptic loosening. Further follow-up is required to determine if these results can be durable over a longer period.  相似文献   

19.
The purpose of this study was to investigate the relatively long-term outcomes in 50 patients (54 hips) younger than 50 years of age who underwent total hip arthroplasty using highly cross-linked polyethylene (HXLPE) liners. With a minimum follow-up of 10 years, mean age at time of surgery was 38.9 years (range, 15–50 years). Survivorship was 100%. There was no radiographic evidence of osteolysis or component loosening. Mean steady-state femoral head penetration rate was 0.020 ± 0.0047 mm/yr. Clinical outcomes were excellent, with mean Harris hip score of 91.2 (range, 72–99) points at final follow-up.  相似文献   

20.
Long term total hip arthroplasty follow-up has demonstrated bearing surface wear and failure of fixation as the major modes of failure. The purpose of this study was to evaluate the minimum 10 year results of a third generation cementless acetabular component using moderately cross-linked polyethylene liners. 150 primary THAs were evaluated clinically for need for revision and activity evaluated using accelerometers, WOMAC, Tegner and UCLA activity-level scores. Radiographs were evaluated for wear, osteolysis and loosening. We compared this cohort to three of our previously reported cohorts. The only revision was unrelated to liner wear and all acetabular components were bone ingrown. There were no cases of acetabular osteolysis and one case of femoral osteolysis. Average steps per year were 1.59 million. Mean steady state wear rate averaged 0.04 mm/year. At 10-years, excellent fixation and low wear were demonstrated using a cementless acetabular construct and moderately cross-linked polyethylene liner.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号