首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Transesophageal echocardiography and standard two-dimensional echocardiography were performed in 15 patients with suspected coarctation of the aorta. Aortic diameters and crosssectional areas were determined by means of TEE and compared with clinical findings and catheterization data. The isthmus of the aorta could be imaged in all patients using TEE, but in only seven patients using standard suprasternal echocardiography. Compared with controls, aortic diameters were narrowed in 9 of 15 patients, and cross-sectional areas were reduced in 13 of 15. There was a satisfactory correlation between TEE data and angiographic and hemodynamic data. TEE is a promising method of a diagnosing and quantifying coarctation of the aorta, and is more sensitive than conventional two-dimensional and Doppler echocardiography.  相似文献   

2.

Background

There has been a substantial increase in the number of imaging studies performed to assess thoracic aortic pathology. We sought to determine the accuracy of transthoracic echocardiography (TTE) compared to transesophageal echocardiography (TEE) for measuring ascending aortic size.

Hypothesis

Transthoracic echocardiography is reasonably accurate for assessing ascending aortic dimension.

Methods

Fifty‐two patients with or without aortic disease underwent both TTE with nonstandard views and TEE. The ascending aorta was measured at 4 levels by 2 blinded observers for each modality. Pearson's correlation coefficients were determined and Bland‐Altman plots and analyses were constructed. Inter‐ and intraobserver variability was determined in a random subgroup of patients.

Results

The mean age of the group was 65.5 years old and 15% had aortic dilation >4.0 cm. A strong positive correlation between the 2 imaging modalities was seen at all levels with the highest correlation for the maximum diameter of the ascending aorta (r = 0.936, P < 0.0001). Interobserver and intraobserver variability showed a good intraclass correlation among readers and among the same reader at all levels.

Conclusions

Transthoracic echocardiography using nonstandard imaging windows is accurate in comparison to TEE for measurement of the ascending aorta at multiple levels in patients with or without aortic pathology. The findings of this study provide support for selected serial follow‐up of patients with aortic disease by TTE only. Copyright © 2008 Wiley Periodicals, Inc. The authors have no funding, financial relationships, or conflicts of interest to disclose.  相似文献   

3.
An 80-year-old woman with acute posterolateral myocardial infarction, cardiogenic shock, and acute heart failure was admitted to our hospital. Transthoracic echocardiography (TTE) showed dysfunction of the left ventricular inferolateral wall motion and severe mitral valve regurgitation (MR). Emergency coronary angiography revealed triple-vessel stenosis. We performed transesophageal echocardiography in the catheter room to diagnose the cause of MR. Severe tenting of the mitral valve and no rupture of the papillary muscles were revealed. We considered ischemic MR likely to improve with revascularization and performed percutaneous coronary intervention. Subsequently, the patient''s circulatory dynamics rapidly stabilized, and MR was significantly improved on follow-up TTE.  相似文献   

4.
5.
6.
7.
Atherosclerotic plaques had been imaged but not quantitated in the thoracic aorta using transesophageal echocardiography. The aim of this study was to describe a method for measuring the atherosclerotic plaque area in the descending aorta by transesophageal echocardiography (TEE) and to evaluate its reproducibility. TEE examinations were performed by two independent sonographers, in 21 patients with angiographically proven coronary artery disease. Two hundred fifty-six transverse segments (mean 12 ± 3 patient) of the descending aorta were adequately recorded. In each segment the plaque and the lumen areas in the half of the aortic segment distant from the transesophageal probe were measured by one reader in the two studies (intersonographer reproducibility). Interreader reproducibility was also evaluated. The correlation coefficient between the first and second study (intersonographer reproducibility) was 0.81. The standard deviation of the difference between examinations equaled 0.137 cm2 and the mean absolute difference between examinations was 0.003 cm2 (95% CI: –0.015; 0.021; P = 0.75). The correlation coefficient between the two readers was 0.86, the standard deviation of the difference between readers was 0.175 cm2 and the mean absolute difference was 0.006 cm2 (95% CI: –0.029; 0.018; P = 0.63). A method for quantitative measurement of aortic atherosclerotic plaque area was evaluated and found to have high intersonographer and intereader reproducibilities. This method might be used in the future for noninvasive evaluation of regression or progression of aortic atherosclerosis.  相似文献   

8.
9.
10.
11.
Despite theoretical advantages of direct thrombin inhibitors, recent clinical studies failed to show the superiority of hirudin over heparin in patients with acute coronary syndromes. However, these inhibitors have important in vitro differences for the inhibition of clot-bound thrombin that may translate into different in vivo relative efficacy. The effects of two direct thrombin inhibitors, argatroban and hirudin, on the reperfusion of thrombotic arterial occlusion by t-PA were compared. In anesthetized rabbits thrombotic occlusion was induced in the femoral artery. t-PA, aspirin, and various doses of argatroban (1.25, 2.5, and 5.0 mg/kg/h) or hirudin (2.5 and 5.0 mg/kg/h) were administered (six animals in each group). Blood flow was measured for 4 hours. Animals treated with 2.5 mg argatroban more rapidly achieved full reperfusion than those treated with high-dose argatroban or hirudin (P < 0.05). At the doses that induced comparable prolongation of bleeding time, argatroban showed a significantly faster and higher level of reperfusion than hirudin. In animals treated with hirudin, there was a positive correlation between the aPTT and the mean reperfusion blood flow (r = 0.70, P < 0.05). In animals treated with argatroban, this correlation did not exist and the high-dose argatroban was paradoxically less effective in promoting thrombolysis despite greater anticoagulation effects. In this animal model of arterial thrombosis, argatroban was more effective than hirudin in inducing rapid, full reperfusion with t-PA. Although they are both direct thrombin inhibitors, these two agents showed important dose-related differences in efficacy and anticoagulant effects.  相似文献   

12.
13.
Although stent implantation into aortic coarctation has been performed solely under fluoroscopy, we successfully applied intracardiac echocardiography (ICE) to guide this procedure in a 13‐year‐old patient. Placing an intracardiac echocardiographic catheter in the left pulmonary artery facing upward, we readily visualized the precise anatomy of coarctation, measured the pressure gradient, and monitored the stent inflation process. This report suggests a new application of ICE for intervention with structural and vascular diseases other than interatrial septum.  相似文献   

14.
15.
Background: In large necropsy studies dissecting intramyocardial hematoma (DIH) with serpiginous tracts across the myocardial fibers has been reported in both the septum and the left ventricle free wall. Methods: We studied 15 patients admitted to the hospital with acute myocardial infarction (AMI) in which DIH was demonstrated by either transthoracic and/or transesophageal and confirmed intraoperatively or by necropsy. Results: In nine patients the hemorrhagic dissection was predominantly in the septum and in the remaining it was in the free wall of the left ventricle (LV). Myocardial infarction involved the left ventricular inferior wall in two, and the anterior wall in 13 patients. The overall mortality was 47%, and in the group with septal hematoma it reached to 78%. Echocardiography disclosed the various acoustic densities of the evolving intramyocardial hematoma, its extension through the hemorrhagic dissection, its spontaneous reabsorption, as well as its communication with the ventricular cavities. Conclusions: Echocardiography is the method of choice for the noninvasive diagnosis of patients with suspected myocardial rupture and intramyocardial dissection postmyocardial infarction.  相似文献   

16.
In this report, we focus on the specific complications of acute myocardial infarction that are associated with rupture of the myocardium and for which two-dimensional and Doppler color flow echocardiography expedites accurate diagnosis for prompt treatment, including surgical repair, which can be crucial to survival in such cases.  相似文献   

17.

Background

Limited intimal tears (LITs) of the aorta (Class 3 dissection variant) are the least common form of aortic pathology in patients presenting with acute aortic syndrome (AAS). LITs are difficult to detect on imaging and may be underappreciated.

Objectives

This study sought to describe the frequency, pathology, treatment, and outcome of LITs compared with other AAS, and to demonstrate that LITs can be detected pre-operatively by contemporary imaging.

Methods

The authors retrospectively reviewed 497 patients admitted for 513 AAS events at a single academic aortic center between 2003 and 2012. AAS were classified into classic dissection (AD), intramural hematoma, LIT, penetrating atherosclerotic ulcer, and rupturing thoracic aortic aneurysm. The prevalence, pertinent risk factors, and detailed imaging findings with surgical and pathological correlation of LITs are described. Management, early outcomes, and late mortality are reported.

Results

Among 497 patients with AAS, the authors identified 24 LITs (4.8% of AAS) in 16 men and 8 women (17 type A, 7 type B). Patients with LITs were older than those with AD, and type A LITs had similarly dilated ascending aortas as type A AD. Three patients presented with rupture. Eleven patients underwent urgent surgical aortic replacement, and 2 patients underwent endovascular repair. Medial degeneration was present in all surgical specimens. In-hospital mortality was 4% (1 of 24), and in total, 5 patients with LIT died subsequently at 1.5 years (interquartile range [IQR]: 0.3 to 2.5 years). Computed tomography imaging detected all but 1 LIT, best visualized on volume-rendered images.

Conclusions

LITs are rare acute aortic lesions within the dissection spectrum, with similar presentation, complications, and outcomes compared with AD and intramural hematoma. Awareness of this lesion allows pre-operative diagnosis using high-quality computed tomography angiography.  相似文献   

18.
19.
We describe the presence of a localized echo-free space behind the ascending aorta, which could mimic an aortic dissection. This space was confirmed to be the left atrium by intraoperative contrast echocardiography.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号