首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
Measurement of airborne dust concentrations usually involves drawing a sample of the dust-laden air into the measuring instrument through an inlet. Even if the surrounding air is calm, theoretical calculations predict that large particles may not be sampled accurately due to the combined effects of gravity and inertia on the particles near the sampling inlet. Tests were conducted to determine the conditions of particle size, inlet radius, and flow rare necessary for accurate dust sampling. A coal-dust aerosol was sampled simultaneously through inlets of different diameters at the same volume flow-rate and collected on filters. The dust was removed from the filters and the particles were counted and sized with a Coulter counter. Results showed that published criteria for inlet conditions for correct sampling are overly restrictive and that respirable-size particles are sampled correctly in the normal range or operation of most dust sampling instruments.  相似文献   

5.
For studies of the biological effects of bioaerosols, large samples are necessary. To be able to sample enough material and to cover the variations in aerosol content during and between working days, a long sampling time is necessary. Recently, a high-volume transportable electrostatic field sampler for collection of fine particles has been described. The aim of this study was to investigate whether this sampler can be used for collection of high amounts of authentic bioaerosols that can subsequently be used for biological analysis. The investigation was carried out at a biofuel plant in a straw storage room and in a boiler room over two seasons. The sampled dust was quantified in terms of mass and characterized regarding microbial components and compared with dust sampled by Gravikon and GSP samplers. For the electrostatic field sampler, a prefilter was used to remove large objects. The prefilter was characterized for particle penetration and this testing indicated that the prefilter did not remove particles up to 10 mum, and therefore respirable dust was sampled by the electrostatic field sampler. Using the electrostatic field sampler in the straw storage and in the boiler room, 330 and 315 mg dust (net recovery of the lyophilized dust) was sampled during a period of 7 days, respectively. The sampling rates of the electrostatic field samplers were between 1.34 and 1.96 mg dust per hour, the value for the Gravikon was between 0.083 and 0.108 mg dust per hour and the values for the GSP samplers were between 0.0031 and 0.032 mg dust per hour. The standard deviations of replica samplings and the following microbial analysis using the electrostatic field sampler and GSP samplers were at the same levels. The exposure to dust in the straw storage was 7.7 mg m(-3) when measured by the electrostatic field sampler and 11.8 mg m(-3) when measured by the GSP inhalable dust sampler. The quantity (amount per mg dust) of total fungi, Aspergillus fumigatus, total bacteria, endotoxin and mesophilic actinomycetes sampled by the electrostatic field samplers and the Gravikon samplers varied within the same season by a factor smaller than four. The quantities of some microbial components were higher in the dust collected with all samplers in March than in August. In conclusion, by using the electrostatic field sampler, it was possible to sample replicas of large authentic aerosol samples that can be used, e.g. biological analysis.  相似文献   

6.
7.
The weight stability of the sampling cassette of the IOM sampler for inhalable dust was tested in several weighing experiments. The results show that the reliability of repeated weighings was good, but the absorption of water vapour was slow and varied considerably among cassette specimen. The exponential time constant for water absorption was approximately 4 days, and 15-20 days were needed to obtain weight stability. With the help of cassette blanks the imprecision in dust weight could be held below 0.05 mg, if the cassettes were allowed one week's storage in the weighing room before weighing, both before and after sampling. The IOM sampling cassettes seem to consist of a few subsets, each with identical relative weight increase in a weighing room. To keep the variability low it is important that both the blanks and the cassettes used for sampling come from the same subset. Experiments indicate that the conducting plastic of the IOM sampling cassette may be replaced with another kind of plastic with similar electrical conductivity, but whose humidity absorption is 30 times lower. A lid, which is weighed with the cassette, was designed so that the potential dust loss from the cassette proper to the commercial transport clip was eliminated. A flow adapter, which simplifies the measurement of the air flow during personal sampling, was designed.  相似文献   

8.

Background  

Levels of pesticides and other compounds in carpet dust can be useful indicators of exposure in epidemiologic studies, particularly for young children who are in frequent contact with carpets. The high-volume surface sampler (HVS3) is often used to collect dust samples in the room in which the child had spent the most time. This method can be expensive and cumbersome, and it has been suggested that an easier method would be to remove dust that had already been collected with the household vacuum cleaner. However, the household vacuum integrates exposures over multiple rooms, some of which are not relevant to the child's exposure, and differences in vacuuming equipment and practices could affect the chemical concentration data. Here, we compare levels of pesticides and other compounds in dust from household vacuums to that collected using the HVS3.  相似文献   

9.
10.
The relationship between dust size and penetration for a static horizontal elutriator (Sibata C-30) was measured in calm air. The elutriator as a low-volume air sampler is widely used as a dust size classifier in work environment measurements. The actual penetrations were compared with the theoretical models of the sampler and with sampling convention for respirable dust in work environment measurement. The sampling convention was recently introduced into the Japanese standard for work environment measurement and is based on the ISO 7708 respirable dust convention. The bias of sampled masses from the respirable dust was calculated for two flow rates of the sampler, i.e., 50% cut sizes of 4 microm and 5 microm, from measured penetration curves. The bias of the sampler was overestimated in the 5 microm, 50% cut condition and underestimated in the 4 microm, 50% cut condition for most workplace sampling situations.  相似文献   

11.
Bennett BG 《Health physics》2002,82(5):644-655
Radionuclides produced in atmospheric nuclear tests were widely dispersed in the global environment. From the many measurements of the concentrations in air and the deposition amounts, much was learned of atmospheric circulation and environmental processes. Based on these results and the reported fission and total yields of individual tests, it has been possible to devise an empirical model of the movement and residence times of particles in the various atmospheric regions. This model, applied to all atmospheric weapons tests, allows extensive calculations of air concentrations and deposition amounts for the entire range of radionuclides produced throughout the testing period. Especially for the shorter-lived fission radionuclides, for which measurement results at the time of the tests are less extensive, a more complete picture of levels and isotope ratios can be obtained, forming a basis for improved dose estimations. The contributions to worldwide fallout can be inferred from individual tests, from tests at specific sites, or by specific countries. Progress was also made in understanding the global hydrological and carbon cycles from the tritium and 14C measurements. A review of the global measurements and modeling results is presented in this paper. In the future, if injections of materials into the atmosphere occur, their anticipated motions and fates can be predicted from the knowledge gained from the fallout experience.  相似文献   

12.
In 2000, the American Conference of Governmental Industrial Hygienists (ACGIH(R)) changed its 1971 threshold limit value (TLV) for 8-hour time-weighted average (TWA) exposure to asphalt from 5 mg/m(3) total particulate (generally < or =40 micrometer [microm] diameter) to 0.5 mg/m(3) inhalable particulate (< or =100 microm aerodynamic diameter) as benzene-soluble aerosol. To date, no inhalable particulate sampling method has been standardized and validated for asphalt fume. Furthermore, much of the historical data were collected using total particulate samplers, and the comparability of total versus inhalable size fractions of asphalt fume is not known. Therefore, the present study compared results from two types of asphalt fume samplers: 1) a traditional total particulate sampler with a 37-mm filter in a closed-face cassette with a 4-mm orifice (NIOSH 5042) versus (2) an inhalable particulate sampler designed by the IOM with a 15-mm orifice. A total of 75 simultaneous pairs of samples were collected, including personal and area samples from 19 roofing and asphalt production facilities operated by 7 different manufacturers. Each sample was analyzed for total mass collected and for benzene-soluble mass. Data from the two sampling methods (total versus inhalable) were comparable for asphalt fumes up to an aerosol concentration of 10 mg/m(3). However, we conclude that the traditional total particulate method is preferable, for this reason: The vast majority of asphalt fume particles are <12.5 microm in diameter. The traditional sampler is designed to collect primarily particles < or =40 microm, while the IOM sampler is optimized for collecting particles < or =100 microm. Thus, the traditional sampler is less likely than the IOM sampler to collect the larger-size fraction of airborne particles, most of which are non-asphalt dust.  相似文献   

13.
Measured sampler penetration curves are presented for British personal cyclone samplers and the MRE 113A static horizontal elutriator in calm air. These curves are compared with previous results for these instruments, and with theoretical models of sampler behaviour. The sampling efficiency of the elutriator when facing a moderate wind is discussed. The penetration curves are assessed by comparison with standard sampling conventions for respirable dust.  相似文献   

14.
15.
16.
A newly designed, low-cost, disposable inhalable aerosol sampler was developed to assess workers personal exposure to inhalable particles. This sampler was originally designed to operate at 10 L/min to increase sample mass and, therefore, improve analytical detection limits for filter-based methods. Computational fluid dynamics modeling revealed that sampler performance (relative to aerosol inhalability criteria) would not differ substantially at sampler flows of 2 and 10 L/min. With this in mind, the newly designed inhalable aerosol sampler was tested in a wind tunnel, simultaneously, at flows of 2 and 10 L/min flow. A mannequin was equipped with 6 sampler/pump assemblies (three pumps operated at 2 L/min and three pumps at 10 L/min) inside a wind tunnel, operated at 0.2 m/s, which has been shown to be a typical indoor workplace wind speed. In separate tests, four different particle sizes were injected to determine if the sampler's performance with the new 10 L/min flow rate significantly differed to that at 2 L/min. A comparison between inhalable mass concentrations using a Wilcoxon signed rank test found no significant difference in the concentration of particles sampled at 10 and 2 L/min for all particle sizes tested. Our results suggest that this new aerosol sampler is a versatile tool that can improve exposure assessment capabilities for the practicing industrial hygienist by improving the limit of detection and allowing for shorting sampling times.  相似文献   

17.
18.
The counting of fibres on membrane filters could be facilitated by using size-selective samplers to exclude coarse particulate and fibres that impede fibre counting. Furthermore, the use of thoracic size selection would also remove the present requirement to discriminate fibres by diameter during counting. However, before thoracic samplers become acceptable for sampling fibres, their performance with fibres needs to be determined. This study examines the performance of four thoracic samplers: the GK2.69 cyclone, a Modified SIMPEDS cyclone, the CATHIA sampler (inertial separation) and the IOM thoracic sampler (porous foam pre-selector). The uniformity of sample deposit on the filter samples, which is important when counts are taken on random fields, was examined with two sizes of spherical particles (1 and 10 microm) and a glass fibre aerosol with fibres spanning the aerodynamic size range of the thoracic convention. Counts by optical microscopy examined fields on a set scanning pattern. Hotspots of deposition were detected for one of the thoracic samplers (Modified SIMPEDS with the 10 microm particles and the fibres). These hotspots were attributed to the inertial flow pattern near the port from the cyclone pre-separator. For the other three thoracic samplers, the distribution was similar to that on a cowled sampler, the current standard sampler for fibres. Aerodynamic selection was examined by comparing fibre concentration on thoracic samples with those measured on semi-isokinetic samples, using fibre size (and hence calculated aerodynamic diameter) and number data obtained by scanning electron microscope evaluation in four laboratories. The size-selection characteristics of three thoracic samplers (GK2.69, Modified SIMPEDS and CATHIA) appeared very similar to the thoracic convention; there was a slight oversampling (relative to the convention) for d(ae) < 7 microm, but that would not be disadvantageous for comparability with the cowled sampler. Only the IOM thoracic sampler tended to undersample the fibres relative to the thoracic convention. With the data divided into four classes based on fibre length, the size-selection characteristics appeared to be unaffected by fibre length for GK2.69, Modified SIMPEDS and CATHIA. Only the IOM thoracic sampler (with the foam selector) showed slightly lower selection for longer length classes of fibres. These results indicate that the tested samplers follow the thoracic sampling convention for fibres, and may be used to improve the quality and reliability of samples that are taken when there is likely to be significant background dust.  相似文献   

19.
Isocyanates in the workplace atmosphere are typically present both in gas and particle phase. The health effects of exposure to isocyanates in gas phase and different particle size fractions are likely to be different due to their ability to reach different parts in the respiratory system. To reveal more details regarding the exposure to isocyanate aerosols, a denuder-impactor (DI) sampler for airborne isocyanates was designed. The sampler consists of a channel-plate denuder for collection of gaseous isocyanates, in series with three-cascade impactor stages with cut-off diameters (d(50)) of 2.5, 1.0 and 0.5 mum. An end filter was connected in series after the impactor for collection of particles smaller than 0.5 mum. The denuder, impactor plates and the end filter were impregnated with a mixture of di-n-butylamine (DBA) and acetic acid for derivatization of the isocyanates. During sampling, the reagent on the impactor plates and the end filter is continuously refreshed, due to the DBA release from the impregnated denuder plates. This secures efficient derivatization of all isocyanate particles. The airflow through the sampler was 5 l min(-1). After sampling, the samples containing the different size fractions were analyzed using liquid chromatography-mass spectrometry (LC-MS)/MS. The DBA impregnation was stable in the sampler for at least 1 week. After sampling, the DBA derivatives were stable for at least 3 weeks. Air sampling was performed in a test chamber (300 l). Isocyanate aerosols studied were thermal degradation products of different polyurethane polymers, spraying of isocyanate coating compounds and pure gas-phase isocyanates. Sampling with impinger flasks, containing DBA in toluene, with a glass fiber filter in series was used as a reference method. The DI sampler showed good compliance with the reference method, regarding total air levels. For the different aerosols studied, vast differences were revealed in the distribution of isocyanate in gas and different particle size fractions. The opportunity to obtain detailed information regarding the distribution of isocyanates in aerosols in addition to the total air levels make the DI sampler a valuable tool for studies of possible health effects in the different parts of the airways.  相似文献   

20.
The article contains data on monitoring the atmospheric air pollution in Moscow. Thus, the below figures are presented: beta ranges from 2.6 E-0.5 to 5.7 E-0.04 Bk/m3, airborne pollutants amount to 3-80 mkg/m3, sulfates--0.002-1.58 mkg(S)/m3, nitrates--0.05-0.75 mkg(N2)/m3 ammonium ions--0.12-1.20 mkg (N2)/m3, sulfuric dioxides--0.11-1.20 mkg (S)/m3. nitric dioxides--0.05-0.5 mlg (N2)/m3 and nitric acid--0.01-0.08 mkg (N2)/m3. The concentration of airborne pollutants exceeds the regional European level (22 mkg/m3) and that of Russia's European part (12 ... 28 mkg/m3) approximately by 1.5 times. It is noteworthy that it reaches 50 ... 70 mkg/m3 in large industrial centers of Europe. The share of sulfuric and nitric acids in the total concentration of airborne pollutants is (by weight) 13%. 0.8 g of sulfur per m2/year and 0.34 g of nitrogen per m2/year fall in the area of Sport-and-Recreation Complex No. 3 with precipitations; the average total beta-activity of atmospheric precipitations amounts to 1.2 Bk/m2 per day. An analysis of relationships between the air dustiness, the ashes samples' weight (of the air) and cuvette (precipitations) is indicative of their direct and tense correlation: the correlation coefficient between dust and ashes samples is 0.716, and between dust and ashes samples of cuvettes--0.559. At the same time, an extremely weak correlation should be pointed out between air dustiness and the total beta-activity of samples--the correlation coefficient is 0.184 (during a warm year season), as well as between dustiness and the beta-activity of cuvettes--0.346.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号