首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.

Background

Attenuation correction computed tomography (CT) contributes to an improvement in the diagnostic accuracy of myocardial perfusion imaging (MPI) by single photon emission tomography (SPECT). The aim of this study was to explore the prognosis of patients with major findings by CT according to the results of MPI.

Methods and Results

1506 patients who underwent MPI by SPECT were retrospectively included. Attenuation correction CT images were systematically analyzed for major and minor abnormalities. 830 (55.1%) and 212 (14.1%) patients had minor and major extracardiac findings, respectively. Among patients with major extracardiac findings, the abnormality was previously unknown in 113 (53.3%) patients. 90 (41.9%) had abnormal MPI, 73 (34.4%) had a myocardial infarction scar, 55 (25.9%) had myocardial ischemia, and 38 (17.7%) patients had both myocardial infarction scar and myocardial ischemia. Among the 201 patients available for survival analysis, there were 67 (31.2%) deaths over a follow-up period of 3.2±1.3 years. There was no significant impact on survival arising from MPI, whatever the result. The results were the same among the 103 patients with previously unknown major extracardiac findings.

Conclusion

Extracardiac findings by CT during MPI are frequent. Patients with major extracardiac findings have a poor mid-term outcome, whatever the results of the myocardial perfusion imaging. Extracardiac findings should be systematically checked when attenuation correction CT is performed.
  相似文献   

2.
Incidental noncardiac abnormalities are frequent in myocardial perfusion imaging studies. It is important for interpreting physicians to be aware of the spectrum of abnormalities that can be detected from these studies. This report describes four cases with polycystic kidney disease with or without liver involvement and one case with polycystic liver disease with corroborative radiological studies.  相似文献   

3.
4.
Myocardial infarct size in 41 patients with the first attack of acute transmural myocardial infarction (MI) was assessed by technetium-99m pyrophosphate single photon emission computed tomography (99mTcPYP-SPECT). A ratio of the number of voxels of 99mTcPYP uptake into the infarct area to that into the thorax was calculated as a parameter of MI size. The ratio was positively correlated with both peak CPK activity (r = 0.53, p less than 0.005, n = 24) and extent score in 201TI-SPECT (r = 0.70, p less than 0.005, n = 14) significantly in patients with anterior MI but not in patients with inferior MI. There was also significant negative correlation between the ratio and the left ventricular ejection fraction (LVEF) measured by RI angiography in both acute (r = -0.67, p less than 0.005, n = 18) and chronic (r = -0.75, p less than 0.005, n = 25) phases in patients with anterior MI. Recovery in LVEF at chronic phase was noted in patients with small anterior MI but not with large anterior MI. 8 of 14 patients with inferior MI had right ventricular MI, that might have affected evaluation of MI size and resulted in no correlation between variables. It was suggested that 99mTcPYP-SPECT was a useful method to evaluate MI size and to predict prognosis of cardiac function in patients with anterior MI but not in patients with inferior MI.  相似文献   

5.
6.
7.
8.
Although planar radionuclide techniques provide accurate, noninvasive measurements of myocardial perfusion and function that are of proven clinical value in the evaluation of the cardiac patient, they are limited by poor object contrast and superimposition of surrounding structures. Due to incomplete angular sampling and significant longitudinal distortion, limited angle tomography did not solve these problems. Single photon emission computed tomography (SPECT) can acquire scintillation information over very small angles of rotation and, thus, improve both object contrast and delineation of overlying or adjacent structures without distortion. The early SPECT systems were cumbersome, dependent on individual user developed software, and had extremely long acquisition and processing time. Improved camera design, new software algorithms, and the use of array processors have simplified and standardized quality control, decreased processing time, and minimized the number of user interventions. New image display formats and quantitative methods of analysis have made interpretation less cumbersome, more reliable and highly reproducible. Cardiac SPECT has been used with thallium-201 and gated blood pool imaging in both research and clinical applications and shown an improvement over planar methods of acquisition.  相似文献   

9.
10.
11.
BACKGROUND: Observer variability has been shown with interpretation of planar thallium-201 images. The interpretive reproducibility of technetium-99m sestamibi tomographic imaging is unknown. This study evaluated the interpretive reproducibility of interpretable Tc-99m sestamibi tomographic images among nuclear cardiologists with a wide range of training and experience. METHODS: Three experienced readers (EX) and 3 less-experienced readers (LEX) interpreted 138 exercise and rest Tc-99m sestamibi tomographic images (101 were abnormal in patients with coronary artery disease [CAD], 37 were normal in patients with <5% likelihood of CAD) twice in random sequence without clinical data. Images of good to excellent quality were randomly selected from a database at 2 nuclear cardiology laboratories. Intraobserver and interobserver agreement for global, left anterior descending (LAD) territory, non-LAD first (normal/abnormal) and second (normal/fixed/reversible) order, and defect extent (normal/single-vessel CAD/multi-vessel CAD) were assessed with percent agreement and Cohen's kappa (kappa) statistic. RESULTS: With regard to intraobserver agreement, first and second order ranged from 87% to 94% and 80% to 90% for global, 82% to 96% and 78% to 95% for LAD, and 88% to 91% and 80% to 90% for non-LAD, respectively. Defect extent ranged from 75% to 90%. There were no differences between EX and LEX for global and non-LAD first and second order, LAD first order, and defect extent. LAD second order was 93% for EX compared with 88% (P = .015) for LEX. With regard to interobserver agreement, first and second order ranged from 73% to 89% and 64% to 85% for global, 73% to 93% and 69% to 91% for LAD, and 76% to 88% and 68% to 84% for non-LAD, respectively. Defect extent ranged from 61% to 82%. Global first and second order ranged from 85% to 87% and 78% to 82% for EX compared with 73% to 84% and 64% to 79% for LEX. LAD first and second order ranged from 89% to 91% and 88% to 89% for EX compared with 73% to 91% and 69% to 70% for LEX. Non-LAD first and second order ranged from 82% to 86% and 76% to 77% for EX compared with 76% to 86% and 68% to 81% for LEX. Defect extent ranged from 69% to 75% for EX compared with 59% to 77% for LEX. CONCLUSIONS: There is moderate to excellent interpretive reproducibility with stress Tc-99m sestamibi SPECT imaging among nuclear cardiologists with a wide range of training and experience.  相似文献   

12.
Thirty-two patients with suspected coronary artery disease were studied by single photon emission computed tomography (SPECT) imaging with oblique reconstructions of the myocardium following the intravenous administration of technetium-99m methoxy isobutyl isonitrile at peak exercise. All patients also underwent three-vessel coronary angiography. The SPECT technique produced very detailed images allowing easy delineation of localized myocardial defects. Segmental myocardial uptake defects were compared with diseased vessels as shown at angiography. A good correlation was shown between right coronary artery (RCA) disease and mid and proximal inferior segments and between left circumflex (LCx) artery disease and mid and proximal lateral segments, allowing accurate localization of a defect to one of these two vessels' territories. Sensitivity and specificity of detection of disease of the RCA and LCx artery were high. Defects associated with a lesion of the left anterior descending vessel were more variable.  相似文献   

13.
14.
15.
16.
17.
18.
19.
20.
In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with 99mTc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (”reverse redistribution pattern”). Coronary angiography was performed in eight patients with positive 99mTc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that 99mTc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole 99mTc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. Received 20 November 1998 and in revised form 19 February 1999  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号