首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
ObjectiveWe aimed to compare the aortic valve area (AVA) calculated using fast high-resolution three-dimensional (3D) magnetic resonance (MR) image acquisition with that of the conventional two-dimensional (2D) cine MR technique.Materials and MethodsWe included 139 consecutive patients (mean age ± standard deviation [SD], 68.5 ± 9.4 years) with aortic valvular stenosis (AS) and 21 asymptomatic controls (52.3 ± 14.2 years). High-resolution T2-prepared 3D steady-state free precession (SSFP) images (2.0 mm slice thickness, 10 contiguous slices) for 3D planimetry (3DP) were acquired with a single breath hold during mid-systole. 2D SSFP cine MR images (6.0 mm slice thickness) for 2D planimetry (2DP) were also obtained at three aortic valve levels. The calculations for the effective AVA based on the MR images were compared with the transthoracic echocardiographic (TTE) measurements using the continuity equation.ResultsThe mean AVA ± SD derived by 3DP, 2DP, and TTE in the AS group were 0.81 ± 0.26 cm2, 0.82 ± 0.34 cm2, and 0.80 ± 0.26 cm2, respectively (p = 0.366). The intra-observer agreement was higher for 3DP than 2DP in one observer: intraclass correlation coefficient (ICC) of 0.95 (95% confidence interval [CI], 0.94–0.97) and 0.87 (95% CI, 0.82–0.91), respectively, for observer 1 and 0.97 (95% CI, 0.96–0.98) and 0.98 (95% CI, 0.97–0.99), respectively, for observer 2. Inter-observer agreement was similar between 3DP and 2DP, with the ICC of 0.92 (95% CI, 0.89–0.94) and 0.91 (95% CI, 0.88–0.93), respectively. 3DP-derived AVA showed a slightly higher agreement with AVA measured by TTE than the 2DP-derived AVA, with the ICC of 0.87 (95% CI, 0.82–0.91) vs. 0.85 (95% CI, 0.79–0.89).ConclusionHigh-resolution 3D MR image acquisition, with single-breath-hold SSFP sequences, gave AVA measurement with low observer variability that correlated highly with those obtained by TTE.  相似文献   

2.
3.
Multidetector CT (64 Slices) of the liver: examination techniques   总被引:4,自引:0,他引:4  
Laghi A 《European radiology》2007,17(3):675-683
Sixty-four-row MDCT, although developed primarily for cardiac imaging, has the potential to have a great impact on liver imaging as well. Liver-imaging protocols with sub-millimeter collimation improve longitudinal spatial resolution, making the acquired dataset a real isotropic volume perfectly designed for optimal three-dimensional rendering and accurate organ and lesion volumetry. The 64-row detector array offers a wide volumetric coverage (up to 40 mm), suitable not only for shortening scanning time and improving spatial resolution, but also for including a large volume per single rotation, particularly useful for accurate CT perfusion studies. In order to take full benefit from the enormous performance offered by new 64-row MDCT scanners, imaging protocols need to be redesigned. Due to the extremely short scanning window, contrast agent injection should be performed at high flow rate and followed by saline bolus chaser; the use of highly concentrated contrast media might be useful. Timing should be accurately calculated either by a test bolus or, better, by using an automatic bolus-detection technique. Radiation exposure is kept under control, using automatic device-modulating dose delivery according to the patient’s anatomy. Finally, the evaluation of acquired volumetric datasets needs the extensive use of a dedicated workstation, with software with sophisticated rendering capabilities.  相似文献   

4.
We describe an unusual case of aortic dissection causing spinal cord infarction. The dissection arose from an intimal tear at the suture line of a coronary artery bypass graft. CT was used to diagnose the dissection and to demonstrate its extension to the aortoiliac bifurcation and innominate artery and its rupture into the left pleural cavity. The most common causes of intimal tears following cardiac bypass surgery are aortic cross-clamping, aortic cannulation, and injury during suturing of the graft to the aorta. An underlying disease of the aorta such as atherosclerosis, cystic medial necrosis, or aortitis is commonly present. CT is an accurate and safe means of detecting aortic dissections following cardiac surgery, and is also useful in assessing the extent of the dissection and identifying its rupture into the pleural or pericardial cavity.  相似文献   

5.
BackgroundThe underlying mechanism of aortic regurgitation and aortic valve and root characteristics are associated with the durability of surgical repair.ObjectiveWe investigated whether multidetector CT (MDCT) identifies the characteristics of the aortic valve and root that may be associated with the ability to perform successful surgical repair.MethodsSixty-one patients with aortic regurgitation and/or aortic root pathology who were evaluated for aortic valve or root repair and underwent clinically indicated gated or nongated MDCT of the aortic valve and aortic root were included in the present analysis. Patients with endocarditis were excluded. MDCT data of aortic valve anatomy and calcification and thoracic aorta dimensions were analyzed.ResultsThe aortic valve and root was successfully repaired in 36 patients (55 ± 13 years; 61% male; median EuroSCORE II, 3.8%) whereas in 25 patients (56 ± 15 years; 52% male; median EuroSCORE II, 2.5%) repair was not attempted (n = 20) or valve repair was converted to aortic valve replacement during surgery (n = 5). In patients in whom repair was considered not possible or failed, there was a higher percentage of bicuspid aortic valves (48% vs 17%; P = .019), more severe commissural calcification, and more severe annular calcification.ConclusionThe degree of commissural and annular calcification of the aortic valve determined by MDCT is inversely related to the ability to perform surgical valve repair instead of replacement. Similarly, bicuspid valve anatomy predicts failure to perform repair.  相似文献   

6.
MDCT angiography has enabled visualization of left atrium in addition to coronary arteries. CT images can be utilized to demonstrate normal anatomy and pathologies. Left atrium variations and pathologies include atrial septal pouch, patent foramen ovale, atrial septal defect, atrial band, lipomatous hypertrophy, cor triatriatum, diverticulum, accessory appendages, atrial thrombus and masses. Left atrium should be carefully evaluated in patients undergoing coronary CT angiography. MDCT is becoming an alternative modality for the evaluation of left atrium.  相似文献   

7.

Objective

This preliminarily study was designed to determine and to compare the efficacy of two commercially available barium-based fecal tagging agents for CT colonography (CTC) (high-density [40% w/v] and low-density [4.6% w/v] barium suspensions) in a population in Korea.

Materials and Methods

In a population with an identified with an average-risk for colorectal cancer, 15 adults were administered three doses of 20 ml 40% w/v barium for fecal tagging (group I) and 15 adults were administered three doses of 200 ml 4.6% w/v barium (group II) for fecal tagging. Excluding five patients in group I and one patient in group II that left the study, ten patients in group I and 14 patients in group II were finally included in the analysis. Two experienced readers evaluated the CTC images in consensus regarding the degree of tagging of stool pieces 6 mm or larger. Stool pieces were confirmed with the use of standardized CTC criteria or the absence of matched lesions as seen on colonoscopy. The rates of complete fecal tagging were analyzed on a per-lesion and a per-segment basis and were compared between the patients in the two groups.

Results

Per-lesion rates of complete fecal tagging were 52% (22 of 42; 95% CI, 37.7-66.6%) in group I and 78% (28 of 36; 95% CI, 61.7-88.5%) in group II. The difference between the two groups did not reach statistical significance (p = 0.285). The per-segment rates of complete tagging were 33% (6 of 18; 95% CI, 16.1%-56.4%) in group I and 60% (9 of 15; 95% CI, 35.7%-80.3%) in group II; again, the difference between the two groups did not reach statistical significance (p = 0.171).

Conclusion

Barium-based fecal tagging using both the 40% w/v and the 4.6% w/v barium suspensions showed moderate tagging efficacy. The preliminary comparison did not demonstrate a statistically significant difference in the tagging efficacy between the use of the two tagging agents, despite the tendency toward better tagging with the use of the 4.6% w/v barium suspension.  相似文献   

8.

Purpose

The purpose of this study was to compare planimetric aortic valve area (AVA) measurements from 256-slice CT to those derived from transesophageal echocardiography (TEE) and cardiac catheterization in high-risk subjects with known high-grade calcified aortic stenosis.

Methods and materials

The study included 26 subjects (10 males, mean age: 79 ± 6; range, 61–88 years). All subjects were clinically referred for aortic valve imaging prior to percutaneous aortic valve replacement from April 2008 to March 2009. Two radiologists, blinded to the results of TEE and cardiac catheterization, independently selected the systolic cardiac phase of maximum aortic valve area and independently performed manual CT AVA planimetry for all subjects. Repeated AVA measurements were made to establish CT intra- and interobserver repeatability. In addition, the image quality of the aortic valve was rated by both observers. Aortic valve calcification was also quantified.

Results

All 26 subjects had a high-grade aortic valve stenosis (systolic opening area <1.0 cm2) via CT-based planimetry, with a mean AVA of 0.62 ± 0.18. In four subjects, TEE planimetry was precluded due to severe aortic valve calcification, but CT-planimetry was successfully performed with a mean AVA of 0.46 ± 0.23 cm2. Mean aortic valve calcium mass score was 563.8 ± 526.2 mg. Aortic valve area by CT was not correlated with aortic valve calcium mass score. A bias and limits of agreement among CT and TEE, CT and cardiac catheterization, and TEE and cardiac catheterization were −0.07 [–0.37 to 0.24], 0.03 [−0.49 to 0.55], 0.12 [−0.39 to 0.63] cm2, respectively. Differences in AVA among CT and TEE or cardiac catheterization did not differ systematically over the range of measurements and were not correlated with aortic valve calcium mass score.

Conclusion

Planimetric aortic valve area measurements from 256-slice CT agree well with those derived from TEE and cardiac catheterization in high-risk subjects with known high-grade calcified aortic stenosis.  相似文献   

9.
The aim of this study was to determine the sensitivity, specificity, and diagnostic accuracy of helical computed tomography (CT) without oral, intravenous, or rectal administration of contrast material in confirming the diagnosis of acute appendicitis in patients with suggestive clinical and laboratory findings. One hundred and thirty patients with suspected acute appendicitis underwent an unenhanced helical CT scan. Scans were obtained in a single breath-hold from the level of umbilicus to the pubic symphysis using a 5-mm collimation. Oral, intravenous, or rectal contrast materials were not used. The criteria for diagnosis of acute appendicitis included an enlarged diameter of appendix more than 6 mm with associated periappendiceal inflammation. The results yielded a sensitivity of 94.7%, a specificity of 91.7%, an accuracy of 93.8%, a positive predictive value of 96.7%, and a negative predictive value of 86.8%. Unenhanced helical CT accurately diagnoses acute appendicitis, and it protects the patients from unnecessary further time-consuming diagnostic procedures, the risks associated with contrast material administration, and unnecessary surgical interventions. Electronic Publication  相似文献   

10.
The purpose of this study was to compare sensitivity, specificity, and postprocessing time of a colon dissection approach to regular 3D-endoluminal workup of computed tomography (CT) colonography for the detection of polypoid lesions. Twenty-one patients who had received conventional colonoscopy after CT colonography were selected; 18 patients had either colon polyps or colon cancer and three had no findings. CT colonography was performed using a 4-channel multi-detector-row (MDR) CT in ten cases and a 16-channel MDR-CT in 11 cases. A blinded reader retrospectively evaluated all colonographies using both viewing methods in a randomized order. Thirty-seven polyps were identified by optical colonoscopy. An overall per-lesion sensitivity of 47.1% for lesions smaller than 5 mm, 56.3% for lesions between 5 mm and 10 mm, and 75.0% for lesion larger than 10 mm was calculated using the colon dissection approach. This compared to an overall per-lesion sensitivity of 35.3% (<5 mm), 81.5% (5–10 mm), and 100.0% (>10 mm) using the endoluminal view. The average time consumption for CT colonography evaluation with the colon dissection software was 10 min versus 38 min using the endoluminal view. A colon dissection approach may provide a significant time advantage for evaluation of CT colonography while obtaining a high sensitivity. It is especially superior in the detection of lesions smaller than 5 mm.  相似文献   

11.

Objective

We wanted to prospectively evaluate the interobserver agreement between radiology residents and expert radiologists for interpreting CT images for making the diagnosis of pulmonary embolism (PE).

Materials and Methods

We assessed 112 consecutive patients, from April 2007 to August 2007, who were referred for combined CT pulmonary angiography and indirect CT venography for clinically suspected acute PE. CT scanning was performed with a 64×0.5 collimation multi-detector CT scanner. The CT studies were initially interpreted by the radiology residents alone and then the CT images were subsequently interpreted by a consensus of the resident plus an experienced general radiologist and an experienced chest radiologist.

Results

Two of the 112 CTs were unable to be interpreted (1.7%). Pulmonary artery clots were seen on 36 of the thoracic CT angiographies (32%). The interobserver agreement between the radiology residents and the consensus interpretation was good (a kappa index of 0.73). All of the disagreements (15 cases) were instances of overcall by the resident on the initial interpretation. Deep venous thrombosis was detected in 72% (26 of 36) of the patients who had PE seen on thoracic CT. The initial and consensus interpretations of the CT venography images disagreed for two cases (kappa statistic: 0.96).

Conclusion

It does not seem adequate to base the final long-term treatment of PE on only the resident''s reading, as false positives occurred in 13% of such cases. Timely interpretation of the CT pulmonary angiography and CT venography images should be performed by experienced radiologists for the patients with suspected PE.  相似文献   

12.
RATIONALE AND OBJECTIVES: Serial CT lung studies are difficult to compare due to misregistration between image sets. An optical flow method (OFM) was adapted for use on CT lung images to register images and visualize changes between studies. Three applications were investigated: lung nodule assessment; evaluation of pulmonary enhancement; and functional changes due to air trapping. MATERIALS AND METHODS: From an initial clinical study, a follow-up study was created by digitally manipulating the images to simulate patient positioning errors and nodule growth. Nodule growth was measured from the temporal subtraction of registered images. In application to the assessment of pulmonary enhancement, pre and postcontrast images from a patient with acute pulmonary embolism (PE) were registered. A map of the perfused blood volume was computed from the ratio of aligned lung volumes. Functional changes in the lung were demonstrated using images from a patient with air trapping. End-inspiratory and end-expiratory volumes were aligned and displacement fields estimated using the OFM. Principal strains were computed from the displacement fields. RESULTS: All image volumes were aligned with at least 0.95 correlation. OFM estimates of displacement showed excellent agreement with the prescribed displacements with 0.33 pixel RMS error. Nodule growth was evident in the presence of significant positioning errors. In the PE case, enhancement ratios indicated a hypoperfused area consistent with an occlusive hypodense filling defect. For the air trapping case, a strain map showed functional changes along the interface of the air trap. CONCLUSIONS: The OFM can facilitate the detection and quantification of changes between serial CT lung studies.  相似文献   

13.
CT colonography practice in the UK: a national survey   总被引:3,自引:0,他引:3  
AIM: To determine the provision of computed tomography (CT) colonography in UK radiology departments. MATERIALS AND METHODS: A questionnaire relating to the availability of CT colonography, barriers to implementation, clinical indications, technique, and practitioners was posted to clinical directors of UK radiology departments. RESULTS: One hundred and thirty-eight departments responded. Fifty (36%) offered CT colonography in day-to-day clinical practice. Of those that did not, 68 of 87 (64%) cited limited scanner capacity as the main barrier. Of the 50 departments offering a service, 39 (78%) offered CT after incomplete colonoscopy, 36 (72%), after failed barium enema, and 37 (74%) as an alternative to barium enema. Of those offering a service, the number of studies performed varied between one per month (38%) to more than one per day (8%). Total experience varied between 20 or fewer studies (28%) to more than 300 (12%). Full bowel preparation was common (92%), as was dual positioning (90%). Colonography was interpreted by radiologists with a subspecialty interest in gastrointestinal imaging in 64% of centres offering a service. CONCLUSION: CT colonography is widely available in the UK, with approximately one-third of responders offering a service. Experience and throughput varies considerably. Limited CT scanner capacity is the major barrier to further dissemination.  相似文献   

14.
ObjectiveThe aim of this study was to identify the morphological and functional characteristics of quadricuspid aortic valves (QAV) on cardiac computed tomography (CCT).ResultsAll of the patients had AR; 9 had pure AR, 1 had combined aortic stenosis and regurgitation, and 1 had combined subaortic stenosis and regurgitation. Two patients had a subaortic fibrotic membrane and 1 of them showed a subaortic stenosis. One QAV was misdiagnosed as tricuspid aortic valve on TTE. In accordance with the Hurwitz and Robert''s classification, consensus was reached on the QAV classification between the CCT and TTE findings in 7 of 10 patients. The patients were classified as type A (n = 1), type B (n = 3), type C (n = 1), type D (n = 4), and type F (n = 2) on CCT. A very high correlation existed between ROA by CCT and RF by CMR (r = 0.99) but a good correlation existed between ROA by CCT and regurgitant severity by TTE (r = 0.62).ConclusionCardiac computed tomography provides comprehensive anatomical and functional information about the QAV.  相似文献   

15.
RATIONALE AND OBJECTIVES: To establish the utility of multidetector computed tomography (CT) angiography using dual-head power injector in the diagnosis of aortic diseases. METHODS: In a prospective study, 151 patients with aortic diseases were examined by four-detector CT. Scanning was performed using bolus tracking technique. In all patients nonionic contrast was injected at the rate of 1.5 mL/sec. One hundred one patients were examined with dual-head power injector using 0.6 mL/kg contrast flushed by 30 mL of saline solution (group D). Fifty patients were examined with single-head power injector using 1.0 mL/kg contrast only (group S). We evaluated CT values at descending aorta, upper abdominal aorta, abdominal aortic bifurcation, and bilateral common femoral arteries. RESULTS: There were no statistically significant difference of CT values at descending aorta, upper abdominal aorta, abdominal aortic bifurcation, and right common femoral artery. At left common femoral artery, CT values in group D were higher than those in group S with statistically difference (P < .05). In group D, about 40% dose reduction was achieved without reducing image qualities. CONCLUSION: Multidetector CT angiography using dual-head power injector was valuable for the contrast dose reduction of aortic diseases.  相似文献   

16.
RATIONALE AND OBJECTIVES: The aim of this study is to compare the degree of stair-step artifact on coronal reformation computed tomographic (CT) pulmonary angiography images obtained using single-detector helical CT (SDCT), four-detector (4-MDCT), and eight-detector multidetector-row CT (8-MDCT) and compare the degree of motion artifact on the corresponding axial CT images. MATERIALS AND METHODS: Three groups of consecutive patients imaged by means of CT angiography for suspected pulmonary embolus were retrospectively identified by using CT records at our institution: (1) group A (n = 38), SDCT; (2) group B (n = 36), 4-MDCT; and (3) group C (n = 74), 8-MDCT. For each case, coronal multiplanar volume reformation maximal intensity projection images were created by using a standard technique. All images were reviewed in a randomized fashion by two thoracic radiologists who were blinded to the type of CT scanner. Stair-step artifact of pulmonary arteries on coronal reformation images was graded by consensus agreement using a four-point scale (0 = no artifact to 3 = severe artifact). Axial images were assessed for six parameters of motion artifact. The sum of these grades resulted in a total motion score, with a potential range of 0 (no motion) to 12 (severe motion). Statistical analysis was performed using the Mann-Whitney test. RESULTS: Stair-step artifacts were significantly higher for SDCT (mean, 2.9; median, 3) compared with 4-MDCT (mean, 2.2; median, 2; P < .0001) and 8-MDCT (mean, 1.5; median, 1; P < .0001). Total motion scores were significantly higher for SDCT (mean, 9.3) compared with 4-MDCT (mean, 8.4; P = .03) and 8-MDCT (mean, 6.8; P < .0001). CONCLUSION: Stair-step artifacts are significantly higher with SDCT compared with MDCT. For MDCT, eight-detector scanners produce images with significantly less artifact than four-detector scanners.  相似文献   

17.
RATIONALE AND OBJECTIVES: The aim of this study was to determine the accuracy and reproducibility of low-dose computed tomography (CT) and magnetic resonance (MR) for abdominal adipose tissue quantification on phantom and human studies. MATERIALS AND METHODS: An adiposity phantom (with known internal/external oil volumes) was scanned at three different tube voltages (140, 120, and 90 kVp) using a 16-detector row CT scanner and was imaged using a T1-weighted spin echo MR sequence. For human studies, whole-volume coverage of the abdomen was obtained using CT (at 140 and 90 kVp) and T1-weighted spin echo MR imaging from five obese male volunteers (mean age, 40.6 years; mean body mass index, 30.2). The volumes of total, visceral, and subcutaneous adipose tissues (TAT, VAT, and SAT, respectively) were calculated independently by two radiologists for each CT scan and MR imaging using a computer-aided semiautomatic program. RESULTS: The estimated radiation dose could be reduced by approximately 75% with a 90-kVp protocol as compared with the 140-kVp protocol. Phantom studies showed that there was no statistically significant difference between the four methods in estimating the percentage predicted of the true volumes (measurement errors <4% for all methods, P > .05). In human studies, we found no statistically significant difference between the three methods in TAT, VAT, and SAT volumes (P > .05). Inter- and intraobserver reproducibilities of the CT volume estimates using the 90-kVp protocol were better than those obtained from MR imaging (kappa > 0.9 versus 0.4-0.5; coefficient of variation < 1% versus 15-22%). CONCLUSION: Low-dose CT provides accurate and reproducible measurement of abdominal adipose tissue volumes with a relevant dose reduction.  相似文献   

18.
Sarcoidosis is a systemic disease of unknown cause, characterized by widespread non-caseating granulomas. There is a wide spectrum of radiologic manifestations in pulmonary sarcoidosis, providing challenges to radiologists. However, recognition of the key features of sarcoidosis with knowledge of its pathologic background can often allow for specific diagnosis. In this review, we describe the variety of high-resolution CT findings in pulmonary sarcoidosis along with its pathologic features as the basis for radiographic manifestations, and discuss the key features on high-resolution CT for the specific diagnosis of pulmonary sarcoidosis.  相似文献   

19.
PURPOSE: To assess the influence of different temporal sampling rates on the accuracy of the results from cerebral perfusion CTs in patients with an acute ischemic stroke. MATERIAL AND METHODS: Thirty consecutive patients with acute stroke symptoms received a dynamic perfusion CT (LightSpeed 16, GE). Forty millilitres of iomeprol (Imeron 400) were administered at an injection rate of 4 ml/s. After a scan delay of 7s, two adjacent 10mm slices at 80 kV and 190 mA were acquired in a cine mode technique with a cine duration of 49 s. Parametric maps for the blood flow (BF), blood volume (BV) and mean transit time (MTT) were calculated for temporal sampling intervals of 0.5, 1, 2, 3 and 4s using GE's Perfusion 3 software package. In addition to the quantitative ROI data analysis, a visual perfusion map analysis was performed. RESULTS: The perfusion analysis proved to be technically feasible with all patients. The calculated perfusion values revealed significant differences with regard to the BF, BV and MTT, depending on the employed temporal resolution. The perfusion contrast between ischemic lesions and healthy brain tissue decreased continuously at the lower temporal resolutions. The visual analysis revealed that ischemic lesions were best depicted with sampling intervals of 0.5 and 1s. CONCLUSION: We recommend a temporal scan resolution of two images per second for the best detection and depiction of ischemic areas.  相似文献   

20.
The purpose of this study was to analyze different patient positioning strategies for minimizing artifacts of the shoulder girdle in head and neck CT. Standardized CT examinations of three positioning groups were compared (P: patients pushed their shoulders downwards; D: similar optimization by a pulling device; N: no particular positioning optimization). Parameters analyzed were the length of the cervical spine not being superimposed by the shoulder girdle as well as noise in the supraclavicular space. In groups P and D, the portion of the cervical spine not superimposed was significantly larger than in group N (P: 10.4 cm; D: 10.6 cm; N: 8.5 cm). At the supraclavicular space, noise decreased significantly (P: 12.5 HU; D: 12.1 HU; N: 17.7 HU). No significant differences between the two position-optimized groups (P and D) were detected. Optimized shoulder positioning by the patient increases image quality in CT head and neck imaging. The use of a pulling device offers no additional advantages.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号