首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The purpose of the present report was to determine the frequency of a congenitally bicuspid aortic valve in patients ≥80 years of age old with aortic stenosis (AS) severe enough to warrant aortic valve replacement. Transcatheter aortic valve implantation (TAVI) has traditionally been reserved for patients ≥80 years of age with severe AS involving a 3-cuspid aortic valve. Traditionally, AS involving a 2-cuspid aortic valve has been a contraindication to TAVI. We examined operatively excised stenotic aortic valves in 364 patients aged ≥80 years to determine the frequency of an underlying congenitally bicuspid aortic valve. Of the 347 octogenarians and 17 nonagenarians, 78 (22%) and 3 (18%) had stenotic congenitally bicuspid aortic valves, respectively. In conclusion, because the results of TAVI are less favorable in patients with stenotic congenitally bicuspid valves than in patients with stenotic tricuspid aortic valves, proper identification of the underlying aortic valve structure is important when considering TAVI as a therapeutic procedure for AS in older patients.  相似文献   

2.
We sought to measure the accuracy of 2-dimensional transthoracic echocardiography in determining aortic valve structure in patients with aortic stenosis (AS) undergoing aortic valve replacement (AVR). Few studies have compared aortic valve structure determined by echocardiogram to that determined by examination of the operatively excised stenotic aortic valve. Two-dimensional echocardiograms were reviewed and interpreted by an expert echocardiographer in blinded fashion in 100 patients >50 years of age (mean 70) who had undergone AVR for isolated AS ± aortic regurgitation and the aortic valve structure (unicuspid, bicuspid, tricuspid) was compared to that from examination of the operatively excised stenotic valve. After excluding 14 cases in which echocardiograms were uninterpretable because of heavy calcium and/or poor image quality, congenitally malformed valves were present in 44 patients (51%) and tricuspid valves in 42 of the 86 patients (49%). Ten of the 14 patients (71%) with uninterpretable echocardiograms had congenitally malformed valves. Valve structure by echocardiogram was concordant with morphologic interpretation in 57 of 86 patients (66% accuracy, kappa = 0.33). Accuracy trended toward improvement as degree of AS decreased. In patients with valve areas similar to those enrolled in the recent transcatheter aortic valve implantation trial (PARTNER; 0.7 ± 0.2 cm(2)), aortic valve structure was accurately determined by echocardiography in 21 of 35 patients (60%). In conclusion, aortic valve structure was interpretable by transthoracic echocardiogram in 86 of 100 patients and accurate in 57 of these 86 patients (66%).  相似文献   

3.
Although bicuspid aortic valve occurs in an estimated 1% of adults and mitral valve prolapse in an estimated 5% of adults, occurrence of the 2 in the same patient is infrequent. During examination of operatively excised aortic and mitral valves because of dysfunction (stenosis and/or regurgitation), we encountered 16 patients who had congenitally bicuspid aortic valves associated with various types of dysfunctioning mitral valves. Eleven of the 16 patients had aortic stenosis (AS): 5 of them also had mitral stenosis, of rheumatic origin in 4 and secondary to mitral annular calcium in 1; the other 6 with aortic stenosis had pure mitral regurgitation (MR) secondary to mitral valve prolapse in 3, to ischemia in 2, and to unclear origin in 1. Of the 5 patients with pure aortic regurgitation, each also had pure mitral regurgitation: in 1 secondary to mitral valve prolapse and in 4 secondary to infective endocarditis. In conclusion, various types of mitral dysfunction severe enough to warrant mitral valve replacement occur in patients with bicuspid aortic valves. A proper search for mitral valve dysfunction in patients with bicuspid aortic valves appears warranted.  相似文献   

4.
Reports differ regarding the effect of concomitant coronary artery bypass grafting (CABG) in patients who undergo aortic valve replacement (AVR) for aortic stenosis (AS), and no reports have described the effect of aortic valve structure in patients who undergo AVR for AS. A total of 871 patients aged 24 to 94 years (mean 70) whose AVR for AS was their first cardiac operation, with or without first concomitant CABG, were included. Patients who underwent mitral valve procedures were excluded. In comparison with the 443 patients (51%) who did not undergo CABG, the 428 (49%) who underwent concomitant CABG were significantly older, were more often male, had lower transvalvular peak systolic pressure gradients and larger valve areas, had lower frequencies of congenitally malformed aortic valves, had lighter valves by weight, had higher frequencies of systemic hypertension, and had longer stays in the hospital after AVR. Early and late (to 10 years) mortality were similar by propensity-adjusted analysis in patients who did and did not undergo concomitant CABG. Congenitally unicuspid or bicuspid valves occurred in approximately 90% of those aged 21 to 50, in nearly 70% in those aged 51 to 70 years, and in just over 30% in those aged 71 to 95 years. Unadjusted and adjusted survival was significantly higher in patients with unicuspid or bicuspid valves compared to those with tricuspid valves. In conclusion, although concomitant CABG had no effect on the adjusted probability of survival, the type of aortic valve (unicuspid or bicuspid vs tricuspid) significantly affected the unadjusted and adjusted probability of survival.  相似文献   

5.
The frequency of congenitally bicuspid aortic valves in patients having cardiac transplantation (CT) is unknown. We reviewed 243 explanted hearts in patients having CT at Baylor University Medical Center, Dallas from June 1997 through November 2011 to determine the frequency of a bicuspid aortic valve in this population. Of the 243 explanted hearts, 7 (2.9%) were found to have a congenitally bicuspid aortic valve: 3 had severe aortic valve stenosis and before CT had had the aortic valve replaced; the other 4 had normally functioning bicuspid valves and underwent CT for cardiomyopathy (ischemic in 1, idiopathic in 2, and hypertrophic in 1). Review of previously published reports of CT and aortic valve disease disclosed that 4 patients had had aortic valve replacement (AVR) from 2 to 8 years before CT, 3 had AVR or aortic valve repair of the donor heart at the time of CT, and 4 had AVR or transcatheter aortic valve implantation from 1 to 14 years after CT. Some of these aortic valve replacements, before, at the time of, or after CT were in patients with congenitally bicuspid aortic valves. In conclusion, congenitally bicuspid aortic valves were found in 7 of 243 explanted hearts in patients having CT at a single medical center in a 14-year period: 4 had functioned normally and 3 were severely stenotic. Previous reports of patients having AVR or repair before, during, and after CT were reviewed.  相似文献   

6.
The purpose of this study was to determine the effect of simultaneous coronary artery bypass grafting (CABG) and the influence of valve structure on both early and late survival in quadragenarians having aortic valve replacement (AVR) for aortic stenosis (AS) (with or without aortic regurgitation). We analyzed survival and valve structure in 48 adults (12 women), aged 40 to 49 years, having AVR for AS from 1993 through 2005 at Baylor University Medical Center, including 7 (15%) with and 41 (85%) without simultaneous CABG. Of the 48 quadragenarians, none died within 60 days of operation. Assessment of the relation between long-term survival and gender, aortic valve structure, preoperative severity of the AS, and concomitant CABG was not possible due to the low mortality. Four patients (9%) died >60 days after AVR: at 1.8, 6.3, 7.1, and 9.9 years, respectively. The aortic valve was congenitally unicuspid in 15 patients (31%), congenitally bicuspid in 32 (67%), and 3-cuspid in 1 (2%). In conclusion, of the 48 quadragenarians having AVR for AS, 47 (98%) had a congenitally malformed aortic valve, 60-day mortality was zero, and late mortality was low (8%).  相似文献   

7.
The purpose of this study was to determine the effect of simultaneous coronary artery bypass grafting (CABG) and the influence of valve structure on both early and late survival in septuagenarians having aortic valve replacement (AVR) for aortic stenosis (AS) (with or without aortic regurgitation). We analyzed valve structure in 424 septuagenarians having AVR for AS from 1993 through 2005 at Baylor University Medical Center, including 254 (60%) with and 170 (40%) without simultaneous CABG. Of the 424 patients, 8 (2%) had a congenitally unicuspid aortic valve, 179 (42%), a congenitally bicuspid aortic valve, 235 (55%), a 3-cuspid valve, and in 2 patients (1%) the valve structure was indeterminate. Survival data were available in 418 of the 424 patients: 23 (5.5%) died within 30 days of AVR and 9 other patients from 31 to 60 days after AVR (7.7% 60-day mortality). Sixty-day mortality was not affected by congenital valve abnormality (unicuspid/bicuspid 8.5% vs tricuspid 7.0%). In contrast, late survival (up to 13-year follow-up) was affected by valve structure: it was longer in the unicuspid/bicuspid valve structure group than in the tricuspid valve structure (hazard ratio 0.54, 95% confidence intervals 0.36 to 0.81). The hazard ratio was estimated after adjusting for concomitant CABG. In conclusion, aortic valve structure affected late, but not early survival in septuagenarians undergoing AVR for AS.  相似文献   

8.
The purpose of this study was to determine the effect of simultaneous coronary artery bypass grafting (CABG) and the influence of valve structure on both early and late survival in quinquagenarians having aortic valve replacement (AVR) for aortic stenosis (AS) (with or without aortic regurgitation). We analyzed survival and valve structure in 120 quinquagenarians having AVR for AS from 1993 through 2005 at Baylor University Medical Center, including 44 (37%) with and 76 (63%) without simultaneous CABG. Of the 120 patients, 2 (2%) died within 30 days of operation and none from 31 to 60 days postoperatively. Fifteen other patients (13%) died from >60 days to up to 13 years postoperatively. The unadjusted survival analysis showed that late survival was significantly better in the unicuspid/bicuspid valve structure group than in the tricuspid valve structure group (log-rank test p = 0.001), but that it was not affected by gender (male vs female), preoperative severity of the AS (transvalvular peak pressure gradient >50 vs < or =50 mm Hg), or by performance of CABG. The aortic valve was congenitally unicuspid in 18 patients (15%), congenitally bicuspid in 84 (70%), and 3-cuspid in 18 (15%). In conclusion, aortic valve structure affected the unadjusted late survival in quinquagenarians undergoing AVR for AS, but concomitant CABG, gender, and transvalvular peak systolic gradient had no effect.  相似文献   

9.
The purpose of this study was to determine the effect of simultaneous coronary artery bypass grafting (CABG) and the influence of valve structure on both early and late survival in sexagenarians having aortic valve replacement (AVR) for aortic stenosis (AS) (with or without aortic regurgitation). We analyzed survival and valve structure in 289 sexagenarians having AVR for AS from 1993 through 2005 at Baylor University Medical Center, including 147 (51%) with and 142 (49%) without simultaneous CABG. Of the 282 patients with information available, 13 (4.6%) died within 30 days of operation and 1 additional patient, from 31 to 60 days after operation (5.0% 60-day mortality). Sixty-day mortality was similar (6% and 4%) in the groups with and without simultaneous CABG. A total of 66 patients (23%) died from >60 days up to 13 years postoperatively. The unadjusted survival analysis showed that late survival was not affected by gender (male versus female), aortic valve structure (unicuspid, bicuspid, and quadricuspid versus tricuspid) or preoperative severity of the AS (transvalvular peak pressure gradient >50 mm Hg versus < or =50 mm Hg), or by performance of CABG. The aortic valve was congenitally unicuspid in 10 patients (3%), congenitally bicuspid in 170 (59%), 3-cuspid in 107 (37%), congenitally quadricuspid in 1 patient, and the valve structure was indeterminate in 1 patient. In conclusion, gender, valve structure, preoperative severity of the AS, or performance of simultaneous CABG did not effect unadjusted survival in sexagenarians undergoing AVR for AS.  相似文献   

10.
OBJECTIVES: The purpose of this study was to correlate the weights of operatively excised stenotic aortic valves to preoperative transvalvular peak systolic gradients and to calculated aortic valve areas. BACKGROUND: No previous publication has correlated the weights of stenotic aortic valves to the transvalvular gradients or to the calculated aortic valve areas. METHODS: We weighed operatively excised stenotic aortic valves in 324 adults who had undergone preoperative left-sided cardiac catheterization. RESULTS: As the weights of the operatively excised stenotic aortic valves increased (from <1 g to >6 g), the average transvalvular peak systolic pressure gradients progressively increased. For any valve weight, in general, the women had higher average transvalvular gradients (p 相似文献   

11.
We weighed each cusp separately in 200 operatively excised stenotic congenitally bicuspid aortic valves. It was found in 152 patients (76%) that the cusps differed (by > 0.2 g) in weight and in 48 patients (24%) that the cusps were of similar (a < or = 0.2 g difference) weights. In 161 of the 200 patients (80%), raphes were present in 1 cusp; the raphe and nonraphe cusps differed in weight in 120 patients (74%), with the raphe cusps being larger in 89 patients (74%), and were of similar weights in 41 patients (26%). Of the 39 patients with raphes in neither cusp, 32 cusps (82%) differed in weight and 7 (18%) were of similar weights. The weight of each cusp differed more as the total valve weights increased.  相似文献   

12.
OBJECTIVE--To investigate the morphology of congenitally bicuspid aortic valves causing pure valve regurgitation. DESIGN--A case series collected over five years. SETTING--An academic hospital. PATIENTS AND METHODS--One hundred and forty eight excised congenitally bicuspid aortic valves. The morphological findings were correlated with sex, age, clinical history, and data on haemodynamic function before operation. Pure valve regurgitation was defined as grade 3-4/4 with a gradient less than 30 mm Hg. Aortic root dilatation was evaluated angiographically or echocardiographically or both. RESULTS--Three types were recognised: valves that were purely bicuspid (23%), bicuspid valves with a raphe (34%), and valves with an additional indentation of the free edge of the conjoined cusp (43%). In 14 cases pure valve regurgitation was present. Dilatation of the aortic root was present in 47 cases. The relative risk for regurgitation when the aortic root was dilated (compared with no dilatation) was 3.99. The relative risk for valve regurgitation when there was indentation of the conjoined cusp (compared with no indentation) was 4.95. The mean age at operation in patients with pure regurgitation was 56 years, which is significantly younger (p = 0.0008) than that of patients with a congenitally bicuspid valve with combined valve stenosis and regurgitation (64.7 years). CONCLUSIONS--Congenitally bicuspid aortic valves with a central indentation of the free edge of the conjoined cusp seem particularly likely to develop pure aortic valve regurgitation.  相似文献   

13.
OBJECTIVE--To investigate the morphology of congenitally bicuspid aortic valves causing pure valve regurgitation. DESIGN--A case series collected over five years. SETTING--An academic hospital. PATIENTS AND METHODS--One hundred and forty eight excised congenitally bicuspid aortic valves. The morphological findings were correlated with sex, age, clinical history, and data on haemodynamic function before operation. Pure valve regurgitation was defined as grade 3-4/4 with a gradient less than 30 mm Hg. Aortic root dilatation was evaluated angiographically or echocardiographically or both. RESULTS--Three types were recognised: valves that were purely bicuspid (23%), bicuspid valves with a raphe (34%), and valves with an additional indentation of the free edge of the conjoined cusp (43%). In 14 cases pure valve regurgitation was present. Dilatation of the aortic root was present in 47 cases. The relative risk for regurgitation when the aortic root was dilated (compared with no dilatation) was 3.99. The relative risk for valve regurgitation when there was indentation of the conjoined cusp (compared with no indentation) was 4.95. The mean age at operation in patients with pure regurgitation was 56 years, which is significantly younger (p = 0.0008) than that of patients with a congenitally bicuspid valve with combined valve stenosis and regurgitation (64.7 years). CONCLUSIONS--Congenitally bicuspid aortic valves with a central indentation of the free edge of the conjoined cusp seem particularly likely to develop pure aortic valve regurgitation.  相似文献   

14.
Preliminary findings from clinical trials of percutaneous balloon aortic valvuloplasty and intraoperative debridement of calcific deposits in patients with aortic stenosis have suggested that calcified, congenitally bicuspid aortic valves may be less amenable to these techniques than are calcified tricuspid aortic valves. Accordingly, we evaluated the histoarchitecture of calcific deposits in 30 operatively excised aortic valves. Light microscopic sections taken through the calcified aortic valve leaflets disclosed two principal types of histoarchitecture. In 11 aortic valves nodular calcific deposits were superimposed on an underlying fibrotic aortic valve leaflet (type A); in 17 valves calcific deposits were diffusely distributed throughout the body (spongiosa) of the aortic valve leaflets (type B). Two aortic valves could not be classified histologically. These histologic subtypes were not randomly distributed with regard to gross valvular morphology. All 14 bicuspid valves (100%) were type B; in contrast, 11 (69%) of 16 tricuspid aortic valves were type A, and only 3 (19%) of 16 tricuspid valves were type B (p less than 0.01). Both valves with nonclassifiable histologic features were tricuspid on the basis of gross examination. Thus, the histoarchitectural distribution of calcific deposits is different for bicuspid than for tricuspid stenotic aortic valves. The more diffuse distribution of calcium throughout the body of calcified bicuspid aortic valve leaflets may render these valves less amenable to operative and percutaneous valvuloplasty than are calcified tricuspid aortic valve leaflets on which calcific deposits are typically superimposed in nodular form.  相似文献   

15.
The purpose of this study was to determine the effect of simultaneous coronary artery bypass grafting (CABG) and valve structure on both early and late survival in octogenarians having aortic valve replacement (AVR) for aortic stenosis (AS) (with or without aortic regurgitation). Although a number of reports are available in octogenarians having AVR for AS, none have described aortic valve structure. Most have limited numbers of patients and few have described late results. We analyzed survival and valve structure in 196 octogenarians having AVR for AS from 1993 to 2005 at Baylor University Medical Center, including 118 (60%) with and 78 (40%) without simultaneous CABG. Sixty-day mortality, which was identical to 30-day mortality, was similar (10% and 11%) in the groups with and without simultaneous CABG. Unadjusted analysis of late survival (up to 13 year follow-up) was not affected by gender (male vs female), aortic valve structure (bicuspid vs tricuspid) or preoperative severity of the AS (transvalvular peak pressure gradient > 50 vs < or =50 mm Hg), or by performance of CABG. Of the 196 patients, 54 (28%) had a congenitally bicuspid aortic valve, and 142 (72%) had a tricuspid aortic valve. In conclusion, gender, valve structure, preoperative severity of the AS, or performance of simultaneous CABG did not effect survival in octogenarians having AVR for AS.  相似文献   

16.
Rare or unusual causes of chronic, isolated, pure aortic regurgitation   总被引:2,自引:0,他引:2  
Six patients undergoing aortic valve replacement had rare or unusual causes of isolated, pure aortic regurgitation. Two patients had congenitally bicuspid aortic valves with a false commissure (raphe) displaced to the aortic wall ("tethered bicuspid aortic valve"), two had floppy aortic valves, one had a congenital quadricuspid valve, and one had radiation-induced valve damage.  相似文献   

17.
Aortic valve disease is an increasingly common medical problem in the 20th century; however, its pathogenesis is poorly understood. The present paper reviews 247 cases of aortic valves surgically excised over a one-year period, with special attention to the morphological and histological changes observed in surgically excised aortic valves, and to how those changes relate to the mechanisms of valve failure. Patient age ranged from 17 to 86 years, with a mean of 64.1 +/-13.4 years, and there were 156 men (63.2%) and 91 women (36.8%). A total of 172 valves (69.6%) were tricuspid and 75 valves (30.4%) were congenitally abnormal, of which 67 valves (27.1%) were congenitally bicuspid, six valves (2.4%) were congenitally unicommissural and one valve (0.4%) was quadricuspid; the status of one valve could not be determined. Almost 70% of patients had features of aortic stenosis. Calcification was seen in the large majority of cases, with almost 70% of the valves showing either grade 3 or grade 4 calcification. Ulceration of calcific nodules was present in 42.0% of cases and in the majority of the valves with grade 4 calcification. A total of 15% of the valves showed evidence of postinflammatory changes consistent with rheumatic disease. Neovascularization was present in two-thirds of all valves, while one-half showed inflammatory cell infiltrates. Inflammatory cells were composed mainly of lymphocytes and macrophages, and were located primarily near areas of neovascularization. There was no significant difference in the pathological findings between men and women.  相似文献   

18.
This study was designed to evaluate weights of operatively-excised stenotic aortic valves and to compare them with age, sex, body mass index, and presence or absence of concomitant coronary artery bypass grafting. Weights of operatively-excised stenotic aortic valves have not been previously reported. We weighed operatively-excised stenotic valves in 499 patients (aged 19 to 91 years, mean 70), none of whom had mitral valve replacement. The 499 aortic valves ranged in weight from 0.45 to 11.30 g (mean 2.67). The mean weights of the unicuspid and bicuspid valves were heavier than those of the tricuspid valves (4.36 vs 3.34 vs 2.04 g, p <0.05). Mean valve weights were greater in the 304 men than in the 195 women (3.19 vs 1.87 g, p <0.001), in the younger patients than in the older patients (3.13 g in patients 30 kg/m(2) (2.62 vs 2.76 vs 2.57 g). Weights of operatively-excised stenotic aortic valves provide objective evidence of valvular stenosis.  相似文献   

19.
OBJECTIVE: To determine the relative importance of the different causes of isolated aortic valve stenosis in a surgical series, and to relate these to patient characteristics including the rate of insertion of bypass grafts for coronary artery disease. DESIGN: Survey of the clinical and pathological data on patients undergoing aortic valve replacement for isolated stenosis. SETTING: Tertiary care cardiothoracic surgical unit. PATIENTS AND METHODS: 465 adult patients undergoing aortic valve replacement representing a consecutive series in one surgical unit. Retrospective review of patients records and classification of cause of aortic stenosis based on pathological examination of excised valve cusps. RESULTS: 63.7% patients had calcific bicuspid valves, 26.9% tricuspid calcific valves, and 5.4% rheumatic, 2.6% mixed pathology and 1.5% unicommissural valves. The ratio of males to females for bicuspid valves was 1.85:1 and for tricuspid calcific valves 0.76:1. The mean age of patients with bicuspid valves was 64.9 years compared with 73.4 years for those with tricuspid valves. Some 22.3% of patients with bicuspid valves and 44.8% of those with tricuspid valves had sufficient coronary artery disease to necessitate insertion of coronary bypass grafts. The differential rate of insertion of coronary bypass grafts was independent of age. CONCLUSIONS: Bicuspid calcified aortic valves are the predominant cause of isolated aortic valve stenosis followed by tricuspid calcified aortic valves. The sex and age distribution of bicuspid and tricuspid calcific aortic valve stenosis is different. The higher rate of insertion of vascular grafts in tricuspid calcific aortic valves may indicate that risk factors for atherosclerosis enhance cusp calcification in these patients.  相似文献   

20.
OBJECTIVES: This study was designed to study the behavior of a stent deployed inside human stenotic aortic valves. BACKGROUND: Endovascular valved stent (VS) implantation is a promising new therapy for patients with severe calcific aortic stenosis (AS). The precise characteristics of stent deployment in humans have been poorly studied so far. METHODS: Thirty-five patients with severe AS were included in the study. Sixteen patients (46%) had bicuspid aortic valves. A self-expandable stent specifically designed for VS implantation was deployed intraoperatively inside the aortic valve before surgical aortic valve replacement. RESULTS: In tricuspid aortic valves, the shape of stent deployment was circular, triangular, or elliptic in 68%, 21%, or 11%, respectively. Noncircular stent deployment was frequent in bicuspid aortic valves (the elliptic deployment being the rule [79%]), and stent underdeployment was constant. The incidence of gaps between the stent external surface and the aortic valve did not differ between tricuspid and bicuspid valves (58% vs. 43%; p = 0.49). Sharp calcific excrescences protruding inside the stent lumen were present in 3 cases (9%). Ex vivo study of a homemade VS confirmed that the regularity of the coaptation line of the leaflets was critically dependent on the presence or the absence of stent misdeployment. CONCLUSIONS: Stent misdeployment was constant in bicuspid valves and occurred in one-third of cases of tricuspid valves. Premature failure of implanted VS (secondary to valve distortion or traumatic injury to the leaflets by calcific excrescences) might be an important concern in the future.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号