OBJECTIVE: The purpose of this study was to compare conventional sonography, real-time spatial compound sonography, tissue harmonic sonography, and tissue harmonic sonography merged with compound sonography for overall image quality, lesion conspicuity, and elimination of artifacts. SUBJECTS AND METHODS. In this study, 150 lesions in 122 randomly selected patients with various abdominal and pelvic lesions were evaluated. For each lesion, sonograms were obtained with four techniques: conventional sonography, real-time spatial compound sonography, tissue harmonic sonography, and tissue harmonic compound sonography. All images were reviewed and graded independently by two observers for overall image quality, lesion conspicuity, and elimination of artifacts. RESULTS: Statistical analysis showed that for overall image quality, lesion conspicuity, and elimination of artifacts, tissue harmonic compound sonography was significantly superior to all of the other techniques; real-time spatial compound sonography was better than tissue harmonic sonography; and conventional sonography was the least valuable of all (p < 0.001). When data were analyzed separately according to lesion types, tissue harmonic compound sonography was significantly superior for revealing stone diseases, liver cysts, gallbladder polyps, and uterine myomas. For the remainder of lesion groups, spatial compounding was superior to tissue harmonic sonography for all aspects of evaluation, and conventional sonography was the least valuable (p < 0.05). CONCLUSION: In abdominal and pelvic scanning, tissue harmonic compound sonography provides the best overall image quality, best lesion conspicuity, and least artifacts of all the evaluated imaging modes. Spatial compound sonography is better than tissue harmonic sonography for the evaluation of lesions in general, despite some differences among lesion groups.  相似文献   

2.
OBJECTIVE: We compared phase-inversion tissue harmonic imaging with fundamental B-mode sonography in the evaluation of focal lesions of the kidney. SUBJECTS AND METHODS: For our prospective study, 114 patients underwent sonography of the kidneys in both modes, fundamental B-mode sonography and phase-inversion tissue harmonic imaging, in a randomly chosen scanning order. Imaging parameters were standardized. Sonographic diagnoses were made under real-time conditions by the examining radiologist. All sonographic diagnoses were compared with a diagnostic reference modality: contrast-enhanced CT, contrast-enhanced MR imaging, or histopathology. Three radiologists different from the examiners evaluated overall image quality, lesion conspicuity, and fluid-solid differentiation for both modalities using hard-copy images. RESULTS: In 70 patients, fundamental B-mode sonography as the first technique depicted 73 of 111 lesions 10 mm or larger and enabled 71 lesions to be correctly characterized (sensitivity, 65.8%; accuracy, 64.0%). As the first mode, phase-inversion tissue harmonic imaging depicted 57 of 65 focal lesions and enabled 54 lesions to be accurately classified in 44 patients (sensitivity, 87.7%; accuracy, 83.1%). The differences in sensitivity and accuracy were statistically significant (95% confidence interval). For overall image quality, lesion conspicuity, and fluid-solid differentiation phase-inversion harmonic imaging was superior to fundamental B-mode sonography (p < 0.0001). CONCLUSION: Phase-inversion tissue harmonic imaging is superior to fundamental B-mode sonography in the sonography of focal kidney lesions because phase-inversion tissue harmonic imaging has better overall image quality, lesion conspicuity, and fluid-solid differentiation. In six cases, phase-inversion tissue harmonic imaging added crucial diagnostic information that changed patient management.  相似文献   

3.
This study aimed to compare conventional sonography, tissue harmonic imaging (THI), spatial compound sonography (SONOCT), and SONOCT+THI for overall image quality, lesion conspicuity, and elimination of artifacts of hepatic lesions. Forty-five patients were randomly selected, and 51 different hepatic lesions were scanned using each of the four techniques. The combined images of SONOCT+THI exhibited the best image quality for solid and cystic lesions, while conventional images were the worst for most hepatic lesions (P<.001). SONOCT was the best for fatty liver.  相似文献   

4.
OBJECTIVE: Spatial compound sonography is a method that obtains sonographic information from several different angles of insonation and combines them to produce a single image. By reducing speckle and improving definition of tissue planes, this method can potentially improve image quality in musculoskeletal sonography. The purpose of our study was to compare real-time spatial compound sonography with conventional high-resolution musculoskeletal sonography. MATERIALS AND METHODS: Thirty-four patients underwent sonography of the musculoskeletal system for a variety of indications. All patients were evaluated using conventional high-resolution sonography and real-time spatial compound sonography performed with a 12-5-MHz multifrequency linear array transducer. Conventional images and compound images depicting the same musculoskeletal structure were obtained in pairs. A total of 118 images (59 image pairs) were randomly assorted and reviewed on a computer monitor by three experienced sonologists working independently. The reviewers were unaware of the type of images they were evaluating. Image quality was rated using a 5-point scale. The image parameters evaluated were definition of tissue planes, speckle, other noise, and image detail. RESULTS: Analysis of variance revealed that real-time spatial compound sonography significantly improved definition of soft-tissue planes, reduced speckle and other noise, and improved image detail when compared with conventional high-resolution sonography (p < 0.0001 for all evaluated parameters). CONCLUSION: Real-time spatial compound sonography significantly improved sonographic image quality in the musculoskeletal system when compared with conventional high-resolution sonography. Because musculoskeletal sonography is highly dependent on image quality and tissue-plane definition, spatial compound sonography represents an important development.  相似文献   

5.
Tissue harmonic imaging in the evaluation of acute pancreatitis   总被引:2,自引:0,他引:2  
To evaluate the role of tissue harmonic imaging (THI) in acute pancreatitis, and to compare its findings with conventional grey-scale sonography and contrast-enhanced computed tomography (CECT) scan, we evaluated 25 patients diagnosed with acute pancreatitis on clinical examination and laboratory findings. Conventional grey-scale ultrasound followed by tissue harmonic sonography was done on the same machine followed by a CECT within 12 h of the ultrasound examination. The present study showed that sonograms obtained with THI were of much better quality than those obtained conventionally, especially for the pancreatic tail. The benefits of harmonic imaging were more apparent in obese patients and in others whose body habitus was unfavourable for sonography. In the assessment of pancreatic image quality, grey-scale imaging had an accuracy of 60, 80 and 28% in relation to the head, body and tail, respectively. In comparison, THI had a far higher accuracy of 80, 92 and 60% in relation to the head, body and tail, respectively, with the superiority being most obvious in the pancreatic tail region. There were no cases in which tissue harmonic sonography provided less information than conventional sonography. However, CECT scan remained the best modality in all patients for the evaluation of acute pancreatitis. It showed superior demonstration of all the morphological changes, ranging from minimal pancreatic oedema to extensive fluid collections, necrosis and the haemorrhage that developed in fulminant severe pancreatitis. Our experience thus suggests that THI cannot replace CT scan as the gold standard in the assessment of acute pancreatitis, as it is poor in evaluating the pancreatic tail, cannot clearly distinguish phlegmon from necrosis, and is inferior to CT in the assessment of the complications of acute pancreatitis.  相似文献   

6.
Dynamic sonography of hepatic tumors   总被引:15,自引:0,他引:15  
OBJECTIVE: Our objectives were to propose and evaluate a dynamic sonography protocol for the characterization of hepatic tumors. SUBJECTS AND METHODS: The subjects were 107 patients with focal liver lesions that initially had been found on conventional sonograms. The final diagnoses for the lesions were hepatocellular carcinoma in 60 patients, cholangiocellular carcinoma in six, metastatic carcinoma in 24, hemangioma in 10, and focal fat-spared region in seven. The pulse inversion harmonic imaging mode and a galactose-based contrast agent (Levovist) were used. Dynamic sonography was designed to obtain vascular-phase (composed of the arterial phase and the portal phase) images of the focal lesion and liver-parenchymal-phase images of the whole liver in a series obtained after a bolus injection of the contrast agent. RESULTS: If the whole-tumor or mosaic enhancement patterns (arterial phase) and/or the reticular enhancement (parenchymal phase) are regarded as positive findings for hepatocellular carcinoma, the sensitivity, specificity, and positive predictive value of dynamic sonography in our study were 92%, 96%, and 96%, respectively. If a ring enhancement (arterial to portal phase) or a clear defect (parenchymal phase) or both are regarded as positive findings for cholangiocellular carcinoma or metastasis, the sensitivity, specificity, and positive predictive value were 90%, 95%, and 88%, respectively. If puddle enhancement (portal phase) is regarded as a positive finding for hemangioma, the figures for sensitivity, specificity, and positive predictive value were 60%, 100%, and 100%, respectively. Also, the tumors that showed no focal sign in the liver parenchymal phase were all benign lesions, such as hemangiomas or focal fat-spared regions. CONCLUSION: Dynamic sonography in a protocol combining pulse inversion harmonic imaging and an IV bolus injection of the contrast agent proved to be an effective tool in characterizing liver tumors.  相似文献   

7.
OBJECTIVE: The newly developed contrast-enhanced harmonic gray-scale sonography technique enables us to improve the real-time detectability of viable tumor tissue in hepatocellular carcinoma lesions. We evaluated the usefulness of real-time percutaneous ablation therapy under guidance with this method for patients with hepatocellular carcinoma that is not depicted on conventional sonography. SUBJECTS AND METHODS: We examined 30 patients with 56 hepatocellular carcinomas using real-time contrast-enhanced harmonic gray-scale sonography after injection of a galactose-palmitic acid contrast agent and compared the results with the findings of contrast-enhanced helical CT. We performed percutaneous ablation therapy guided by this modality for treatment of viable hepatocellular carcinoma lesions that could not be detected using conventional sonography. RESULTS: High detection rates of viable hepatocellular carcinoma lesions were obtained using real-time contrast-enhanced harmonic gray-scale sonography (52/56 lesions, 93%); these rates were comparable to those of helical CT (54/56 lesions, 96%). Nine (90%) of the 10 lesions that were not detected on conventional sonography but were depicted on real-time contrast-enhanced harmonic gray-scale sonography (incomplete local treatment, n = 4; small new lesion, n = 6) were successfully treated with percutaneous ablation therapy guided by this method. CONCLUSION: Real-time contrast-enhanced harmonic gray-scale sonography improved the sensitivity for the detection of viable hepatocellular carcinoma lesions. Percutaneous ablation therapy guided by this modality may be useful in patients with hypervascular hepatocellular carcinoma lesions that cannot be detected using conventional sonography.  相似文献   

8.
PURPOSE: The aim of this study was to compare real time compound sonography with conventional sonography in the evaluation of rotator cuff tears. MATERIALS AND METHODS: A prospective study was performed on 50 supraspinatus tendons in 101 patients treated by surgical acromioplasty. The surgeon described 33 (66%) full-thickness tears and 17 (34%) partial-thickness tears. All tendons were examined by conventional sonography and real time compound sonography on the day before surgery. The techniques were compared by evaluating the images for freedom from artefacts, contrast resolution and overall image definition. RESULTS: Real time compound sonography proved to be superior to conventional sonography as regards freedom from artefacts in 50 cases out of 50 (100%). It was superior to conventional sonography in evaluating the image contrast resolution in 45 cases out of 50 (90%), and superior to conventional sonography in overall image definition in 45 out of 50 cases (90%). CONCLUSIONS: Real-time compound sonography reduces the intrinsic artefacts of conventional sonography and allows better overall image definition. In particular, the digital technique allowed us to study the rotator cuff with better contrast resolution and sharper and more detailed images than did conventional sonography.  相似文献   

9.
Kim SH  Lee JM  Kim KG  Kim JH  Han JK  Lee JY  Choi BI 《European radiology》2006,16(11):2444-2453
Image qualities of fundamental, tissue-harmonic, fundamental compound, and tissue-harmonic compound sonography for evaluating focal hepatic lesions were compared. Two radiologists, blinded to the type of techniques and to the final diagnosis, independently evaluated 384 images of 96 hepatic lesions: hemangiomas (n=35), hepatic cystic lesions (n=28), cirrhosis-related nodules (n=22), focal nodular hyperplasia (n=1), and metastases (n=10). All images were graded in terms of lesion conspicuity, margin sharpness, and overall image quality using a 4- or 5-point scale. In the cases of cystic lesions, posterior acoustic enhancement and internal artifacts were also analyzed. A Friedman test was used for multiple statistical comparisons of the four techniques for all parameters. Compound imaging was significantly superior to fundamental imaging regarding lesion conspicuity, margin sharpness, and overall quality (P<0.05). For posterior enhancement and internal artifacts within the cyst, harmonic ultrasonography (US) was significantly better than fundamental US (P<0.05). For evaluating focal hepatic lesions on US, compound imaging provided better lesion conspicuity, better margin sharpness, and better overall image quality than fundamental imaging did. Tissue harmonic imaging also provided better posterior enhancement and fewer internal artifacts of the cyst than fundamental imaging.  相似文献   

10.
OBJECTIVE: Harmonic imaging using phase or pulse inversion technology is a new sonographic diagnostic modality that has the potential to produce images of a higher quality than can be obtained with the conventional method. The aim of this study was to compare both types of harmonic modalities--tissue and contrast harmonic imaging--with the fundamental imaging mode in contrast-enhanced B-mode sonographic diagnosis of vesicoureteral reflux. SUBJECTS AND METHODS: Fifty-four children presenting for diagnostic examination of vesicoureteral reflux underwent standard sonography of the urinary tract in the fundamental mode, followed by intravesical administration of a galactose-based contrast medium containing microbubbles. The contrast-enhanced sonography was conducted by scanning the bladder and each kidney in transverse and longitudinal planes, from ventral and dorsal views, consecutively in B-mode using fundamental, contrast harmonic, and tissue harmonic imaging modalities. Soft-touch buttons on the console screen were used to alternate between the three imaging options, so that switching from one modality to the other could be done almost instantaneously. For comparison, in each patient, we selected one set of contrast-enhanced images of the bladder and two sets, one ventral and one dorsal, of the kidney. In a series, the images were compared and ranked from 1 to 3, with 1 being the best, with regard to sonomorphology (demarcation of the retrovesical space and renal pelvis as the potential sites to look for vesicoureteral reflux) and reflux detection and conspicuity, if present. RESULTS: In all, 248 sets of images were available for comparison. The delineation of both the retrovesical space and the renal pelvis was found to be best with tissue harmonic imaging in 84% and 96% of the image sets, respectively (p < 0.01). Forty-one sets of images were compared from 27 kidney-ureter image units of 22 children (41%) with reflux. The refluxing microbubbles were much more conspicuous in the harmonic imaging mode (tissue harmonic, 100%; contrast harmonic, 93%) than in the fundamental mode (p < 0.01). In eight kidney-ureter units, the reflux was detected only by using the harmonic imaging modalities. CONCLUSION: Visualization of the urinary tract and detection of ultrasound contrast media is significantly improved by the use of the harmonic imaging modalities. When both fundamental and harmonic imaging options are available, we recommend harmonic imaging for contrast-enhanced sonographic diagnosis of vesicoureteral reflux.  相似文献   

11.
The purpose of this preference study is to determine if tissue harmonic imaging (THI) is preferred over conventional sonography for imaging breast masses. A prospective evaluation of 73 identical image pairs (one obtained with conventional sonography, one with THI sonography) was performed, examining 25 cysts, 36 solid masses, and 12 indeterminate lesions. Each image was evaluated for lesion contrast, margins, and overall image quality using a graduated score. Statistical analysis was performed using a modified t test. For cystic and solid lesions, THI was preferred for lesion conspicuity, margin, and overall quality (P<.001). For indeterminate lesions, THI was significantly preferred for lesion conspicuity and overall quality (P<.05), but the preference for margins was not significant. Overall, THI of breast lesions was significantly preferred for lesion contrast and margin evaluation compared to conventional sonography. This modality deserves further evaluation and may improve detection and evaluation of breast lesions.  相似文献   

12.
OBJECTIVE: Our purpose was to compare tissue harmonic imaging with conventional sonography of the biliary tract. SUBJECTS AND METHODS: Eighty patients with suspect biliary disease had conventional sonography and tissue harmonic imaging with an ATL 3000 or 5000 scanner in a 6-month interval. Final diagnoses included malignant biliary obstruction (n = 30), choledocholithiasis (n = 16), sclerosing cholangitis (n = 4), normal or nonobstructed ducts (n = 16), and miscellaneous conditions (n = 14). Similar images were taken with each technique in terms of projection, field of view, focal zone selection, and evidence of disease. Two separate observers blinded to patient data and technique reviewed and graded images individually for the appearance of the lumen of the bile ducts, the length of the visible duct, the appearance of the duct wall, the presence of any intraluminal masses, and the appearance of associated acoustic shadows. Images were graded from zero to 3, with 3 being the best. RESULTS: The median of the 546 tissue harmonic images was one grade higher than the median for the corresponding conventional images (p < 0.0001). Improvements with tissue harmonic imaging included better sharpness of the duct walls (p < 0.01), a clearer lumen (p < 0.0001), identification of a longer length of the common bile duct (p < 0.0001), and improved detection of intraluminal masses (p < 0.006). Acoustic shadows were better defined and blacker with tissue harmonic imaging (p < 0.007). CONCLUSION: Improvement in contrast and reduction of side lobe artifacts with tissue harmonic imaging enhance visualization of the biliary ducts. Tissue harmonic imaging is now our routine technique for bile duct examination.  相似文献   

13.
14.
OBJECTIVE: The purpose of this study was to compare the efficacy of contrast-enhanced pulse inversion harmonic imaging with contrast-enhanced power Doppler sonography and helical CT to determine incomplete local treatment after radiofrequency ablation in patients with hepatocellular carcinoma. MATERIALS AND METHODS: Thirty-five consecutive patients (24 men and 11 women; mean age, 64 years) with 43 hepatocellular carcinomas (3.6 +/- 1.1 cm) were treated using internally cooled radiofrequency ablation therapy. Therapeutic response was evaluated at 4 months with dual-phase contrast-enhanced helical CT, conventional power Doppler Sonography, and pulse inversion harmonic imaging using a sonographic contrast agent (SH-508). CT and sonographic studies were reviewed separately in random order by four radiologists at different consensus conferences. Sensitivity and specificity of the sonographic methods were determined using CT as a gold standard and results were compared using the McNemar test. RESULTS: CT examinations identified residual tumor in 12 lesions (27.9%). Although conventional contrast-enhanced power Doppler sonography identified residual viable tumor foci in four incompletely treated lesions (9.3%), contrast-enhanced pulse inversion harmonic imaging identified residual tumoral enhancement in 10 lesions (23.3%). Thus, the sensitivity of pulse inversion harmonic imaging (83.3%) was significantly greater (p < 0.05) for detecting residual nonablated tumor compared with conventional contrast-enhanced power Doppler sonography. CONCLUSION: Our study suggests that contrast-enhanced pulse inversion harmonic imaging may enable the detection of residual nonablated tumor in more cases than contrast-enhanced power Doppler sonography and may ultimately prove to be a useful adjunct for percutaneous ablation therapies. Nevertheless, contrast-enhanced axial imaging (CT or MR imaging) is currently the most sensitive test for managing thermal ablation for patients with hepatocellular carcinoma.  相似文献   

15.
The value of transvaginal sonography in detecting gynecologic disease currently is being defined. To evaluate transvaginal depiction of the endometrium, transvaginal sonograms were compared with conventional transabdominal scans in 29 patients whose sonograms revealed endometrial abnormalities. The two techniques were compared for image quality and ability to provide unique diagnostic information. Sonographic findings included fluid collections (16), thickened and/or echogenic endometria (10), endometrial irregularities (two), and echogenic foci (two). Clinical diagnoses included early intrauterine pregnancies (five), pseudogestational sacs of ectopic pregnancy (one), intrauterine contraceptive devices (two), endometrial carcinoma (one), and intrauterine synechiae with amenorrhea (Asherman syndrome) (two). In most cases (77%), diagnostic information was obtainable by either transabdominal or transvaginal sonograms, although in 23% transvaginal scanning provided unique diagnostic information not available with the transabdominal technique. In no case did transabdominal sonography contribute diagnostic information not provided transvaginally. The quality of the transvaginal image was judged to be better than that of the transabdominal image in 63% of cases; image quality was the same in 33% of cases and worse in 3% of cases. The results show that transvaginal sonography is often superior to transabdominal scanning in the evaluation of endometrial abnormalities. Transvaginal sonography may be the preferred technique in these cases.  相似文献   

16.
Wöhrle NK  Hellerhoff K  Reiser MF  Clevert DA 《Der Radiologe》2010,50(11):964, 966-964, 972
Recently, the diagnosis of breast diseases by ultrasound has changed radically. It is no longer a complementary modality to mammography but a separate method to investigate breast disease. Innovative high-resolution ultrasound allows more specific diagnosis of breast tumors. Tissue-harmonic imaging not only uses the transmitted, fundamental frequency to obtain an image but also the harmonic frequency. The harmonic signal is processed by the ultrasound system with the result of better delineation of tissue structures and spatial compounding assembles an image from multiple images taken from different angles of echo waves. The effect is the reduction of artifacts with optimized contrast. Finally the advanced speckle reduction technique is used to smooth and homogenize the image. Additionally continuous advancement of new high-resolution linear transducers is responsible for the essential improvement of image quality. In conclusion, it is recommended to integrate all of the described modalities in order to obtain diagnostically conclusive image quality. This article demonstrates the new techniques and applications exemplified using images.  相似文献   

17.
In a retrospective study, we compared transvaginal sonograms with transabdominal sonograms in 67 women referred for evaluation of palpable pelvic masses. The diagnoses included ovarian cyst (27), endometrioma (12), complex cyst (four), dermoid (three), infection (three), ovarian malignancy (two), and uterine fibroid (three). The final diagnosis was made surgically in 41 patients (61%) and by a combination of sonographic and clinical correlation in the remaining patients. More information about the internal architecture or anatomy of the mass was provided by the transvaginal images than by the transabdominal scans in 51 (76%) of the patients. Transabdominal sonography did not provide more diagnostic information in any of the patients examined. Transvaginal sonography was helpful in obese patients, in those with a large amount of bowel gas, and in those unable to achieve adequate bladder filling. Six simple cysts and four complex pelvic masses were identified solely on transvaginal sonograms. The results suggest that transvaginal sonography has considerable advantages over conventional transabdominal sonography in the evaluation of pelvic masses in women.  相似文献   

18.
OBJECTIVE: We evaluated the utility of phase inversion tissue harmonic sonographic imaging in a variety of clinical applications. SUBJECTS AND METHODS: Two hundred randomly selected patients were scanned with both fundamental and tissue harmonic methods on a sonography system. The following transducers were used: 2.5 MHz, 20 mm phased array; 3 MHz, 40 mm curved array; 6.5 MHz, 13 mm curved array transvaginal; and 7.5 MHz, 40 mm linear. Operators evaluated visualization of normal and pathologic tissues by tissue harmonic versus fundamental imaging using scores ranging from 1 for much worse visualization to 5 for much better visualization. They also assessed the overall utility of tissue harmonic imaging in the diagnosis of the patient's condition. The studies were saved on magnetooptical disc and were independently reviewed by one of the authors. RESULTS: Tissue harmonic imaging was helpful for all types of examination. Tissue harmonic imaging improved visualization of normal tissue in 49% of the cases and pathologic tissue in 73% of the cases. Tissue harmonic imaging was found to be diagnostically helpful in 43% of the cases and essential to the diagnosis in 6% of the cases. CONCLUSION: Tissue harmonic imaging significantly improves visualization of both normal and pathologic tissues and its selective use has major diagnostic utility in a wide variety of clinical applications.  相似文献   

19.
OBJECTIVE: The aim of this study was to compare the sensitivity of pulse inversion harmonic digital sonography, unenhanced transabdominal sonography, and ferumoxides-enhanced MR imaging in the depiction of liver metastases. In addition, pulse inversion harmonic digital sonography was performed at different scanning times after Levovist injection to define the best phase for depiction. SUBJECTS AND METHODS: Twenty-six consecutive patients with findings of extrahepatic primary malignancies and liver metastases suspected on transabdominal sonography were examined with both pulse inversion harmonic imaging and ferumoxides-enhanced MR imaging within a 7-day period. Pulse inversion harmonic imaging was performed before and at 20, 100, and 180 sec after a bolus injection of Levovist. MR imaging was performed before and after ferumoxides administration, using breath-hold gradient-recalled echo T1-weighted and turbo spin-echo short tau inversion recovery T2-weighted sequences. Two radiologists independently evaluated image quality, and the number, location, and diameter of lesions scanned using both techniques. Intraoperative sonography or at least 8-month follow-up confirmed the lesions depicted. Analyses included Wilcoxon's signed rank test and Interclass correlation test. RESULTS: Levovist-enhanced pulse inversion harmonic imaging revealed 104 metastases on the first scan after contrast injection, 126 on the second scan, and 118 on the third, compared with 66 on the unenhanced scan. Pulse inversion harmonic digital sonography depicted 90% of lesions shown on ferumoxides-enhanced MR imaging (140 metastases) (p = 0.001). CONCLUSION: Levovist-enhanced pulse inversion harmonic digital sonography is a sensitive technique for depiction of liver metastases. Pulse inversion harmonic digital sonography may have a potential role in imaging patients with possible metastatic involvement of the liver. Further studies are needed to define its place in the workup of these patients. At present, ferumoxides-enhanced MR imaging, being more sensitive, must be performed in all patients in whom pulse inversion harmonic digital sonography is not conclusive or when after pulse inversion harmonic digital sonography, patients remain eligible for surgery.  相似文献   

20.
The sonographic findings in 200 patients who underwent concurrent transabdominal and transvaginal pelvic ultrasound were reviewed. The sonographic techniques were compared for image quality, completeness of anatomic detail depicted, and unique diagnostic information. Transvaginal image quality was better in 79%-87% of scans; transabdominal image quality was better in 3%-5% of scans; images of both techniques were equally good in 10%-18% of scans. The techniques provided equivalent diagnostic information in 60%-84% of cases. Transvaginal sonography was particularly helpful when exclusion of ectopic pregnancy was the clinical concern. Individual organs and fine structures were better seen transvaginally, but the regional survey offered by the transabdominal full-bladder approach remains necessary to provide anatomic orientation, particularly when the patient has not been studied previously.  相似文献   