首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
Backgroud and aimThe usual consumption of nuts reduces cardiovascular diseases (CVD) risk by improving serum lipids and oxidation status. Baru almonds (Dipteryxalata Vog.), a native species of Brazilian Savannah, have considerable contents of monounsaturated fatty acids (MUFA), dietary fiber, vitamin E and zinc, which could exert positive effects in serum lipids and markers of oxidation. However, there is no study about the effect of their consumption on human health. Thus, the aim of this study was to evaluate the effect of baru almonds supplementation on lipid profile and oxidation of mildly hypercholesterolemic subjects.Methods and ResultsA randomized, crossover, placebo controlled study was performed with 20 mildly hypercholesterolemic subjects (total cholesterol (TC) mean ±SEM = 5.8 ± 0.2 mmol/L). The assay had 2 periods of 6 weeks each and a 4-week washout period between the treatments. Subjects were randomly allocated in alternated periods receiving the following treatments per period: supplementation with 20 g/day of baru almonds or placebo (1 corn starch capsule/day). Compared to placebo, supplementation of baru almonds reduced TC (−8.1 ± 2.4%, P = 0.007), low-density lipoprotein cholesterol (LDL-c) (−9.4 ± 2.4%, P = 0.006) and non-high-density lipoprotein cholesterol (non-HDL-c) (−8.1 ± 3.0%, P = 0.013). There were no significant changes on the oxidation biomarkers evaluated.ConclusionDietary supplementation of mildly hypercholesterolemic subjects with baru almonds improved serum lipid parameters, so that this food might be included in diets for reducing the CVD risk.Clinical Trial registryBrazilian Registry of Clinical Trials (ReBEC) (website: http://www.ensaiosclinicos.gov.br). Register number: RBR-4zdy9p.  相似文献   

3.
4.
5.
6.
7.
8.
9.
10.
11.
IntroductionThe diversity, technical skills required, and risk inherent to advanced endoscopy techniques all contribute to complex training curricula and steep learning curves. Since trainees develop endoscopy skills at different rates, there has been a shift towards competency-based training and certification. Validated endoscopy performance measures for trainees are, therefore, necessary. The aim of this systematic review was to describe and critically assess the existing evidence regarding measures of performance for trainees in advanced endoscopy.MethodsA systematic review of the literature from January 1980 to January 2016 was carried out using the MEDLINE, EMBASE, CENTRAL, and ISI Web of knowledge databases. MeSH terms related to 'advanced endoscopy' and 'performance' were applied to a highly sensitive search strategy. The main outcomes were face, content, and construct validity, as well as reliability.ResultsThe literature search yielded 1,662 studies and 77 met the inclusion criteria after abstract and full-text review (endoscopic retrograde cholangiopancreatography (ERCP) = 23, endoscopic ultrasound (EUS) = 30, colonoscopic polypectomy (CP) = 11, balloon-assisted enteroscopy (BAE) = 7, luminal stenting = 3, radiofrequency ablation (RFA) = 2, and endoscopic muscosal resection (EMR) = 1). Good validity and reliability were found for measurement tools of overall performance in ERCP, EUS and CP, with applications for both patient-based and simulator training models. A number of specific technical skills were also shown to be valid measures of performance. These include: selective biliary cannulation, sphincterotomy, biliary stent placement, stone extraction and procedure time for ERCP; pancreatic solid mass T-staging, EUS-guided fine needle aspiration (EUS-FNA) procedure time, number of EUS-FNA passes and puncture precision for EUS; procedure time and en bloc resection rate for CP; retrograde fluoroscopy time for BAE; and mean number of endoscopy sessions required to achieve complete eradication of intestinal metaplasia (CIEM) for RFA. The evidence for EMR and luminal stenting is of insufficient quality to make recommendations.ConclusionsWe have identified multiple valid and readily available performance measures for advanced endoscopy trainees for ERCP, EUS, CP, BAE and RFA procedures. These tools should be considered in advanced endoscopy training programs wishing to move away from apprenticeship-based training and towards competency-based learning with the help of patient-based and simulator tools.  相似文献   

12.
13.
ObjectivesThis study investigated the feasibility of visual and quantitative assessment of coronary vessel wall contrast enhancement (CE) for detection of symptomatic atherosclerotic coronary artery disease (CAD) and subclinical coronary vasculitis in autoimmune inflammatory disease (systemic lupus erythematosus [SLE]), as well as the association with aortic stiffness, an established marker of risk.BackgroundCoronary CE by cardiac magnetic resonance (CMR) is a novel noninvasive approach to visualize gadolinium contrast uptake within the coronary artery vessel wall.MethodsA total of 75 subjects (CAD: n = 25; SLE: n = 27; control: n = 23) underwent CMR imaging using a 3-T clinical scanner. Coronary arteries were visualized by a T2-prepared steady state free precession technique. Coronary wall CE was visualized using inversion-recovery T1 weighted gradient echo sequence 40 min after administration of 0.2 mmol/kg gadobutrol. Proximal coronary segments were visually examined for distribution of CE and quantified for contrast-to-noise ratio (CNR) and total CE area.ResultsCoronary CE was prevalent in patients (93%, n = 42) with a diffuse pattern for SLE and a patchy/regional distribution in CAD patients. Compared with control subjects, CNR values and total CE area in patients with CAD and SLE were significantly higher (mean CNR: 3.9 ± 2.5 vs. 6.9 ± 2.5 vs. 6.8 ± 2.0, respectively; p < 0.001; total CE area: median 0.8 [interquartile range (IQR): 0.6 to 1.2] vs. 3.2 [IQR: 2.6 to 4.0] vs. 3.3 [IQR: 1.9 to 4.5], respectively; p < 0.001). Both measures were positively associated with aortic stiffness (CNR: r = 0.61, p < 0.01; total CE area: 0.36, p = 0.03), hypercholesterolemia (r = 0.68, p < 0.001; r = 0.61, p < 0.001) and hypertension (r = 0.40, p < 0.01; r = 0.32, p < 0.05).ConclusionsWe demonstrate that quantification of coronary CE by CNR and total CE area is feasible for detection of subclinical and clinical uptake of gadolinium within the coronary vessel wall. Coronary vessel wall CE may become an instrumental novel direct marker of vessel wall injury and remodeling in subpopulations at risk.  相似文献   

14.
15.
16.
17.
ObjectivesThis study sought to examine whether imaging of the atrioventricular (AV) membranous septum (MS) by computed tomography (CT) can be used to identify patient-specific anatomic risk of high-degree AV block and permanent pacemaker (PPM) implantation before transcatheter aortic valve implantation (TAVI) with self-expandable valves.BackgroundMS length represents an anatomic surrogate of the distance between the aortic annulus and the bundle of His and may therefore be inversely related to the risk of conduction system abnormalities after TAVI.MethodsSeventy-three consecutive patients with severe aortic stenosis underwent contrast-enhanced CT before TAVI. The aortic annulus, aortic valve, and AV junction were assessed, and MS length was measured in the coronal view.ResultsIn 13 patients (18%), high-degree AV block developed, and 21 patients (29%) received a PPM. Multivariable logistic regression analysis revealed MS length as the most powerful pre-procedural independent predictor of high-degree AV block (odds ratio [OR]: 1.35, 95% confidence interval [CI]: 1.1 to 1.7, p = 0.01) and PPM implantation (OR: 1.43, 95% CI: 1.1 to 1.8, p = 0.002). When taking into account pre- and post-procedural parameters, the difference between MS length and implantation depth emerged as the most powerful independent predictor of high-degree AV block (OR: 1.4, 95% CI: 1.2 to 1.7, p < 0.001), whereas the difference between MS length and implantation depth and calcification in the basal septum were the most powerful independent predictors of PPM implantation (OR: 1.39, 95% CI: 1.2 to 1.7, p < 0.001 and OR: 4.9, 95% CI: 1.2 to 20.5, p = 0.03; respectively).ConclusionsShort MS, insufficient difference between MS length and implantation depth, and the presence of calcification in the basal septum, factors that may all facilitate mechanical compression of the conduction tissue by the implanted valve, predict conduction abnormalities after TAVI with self-expandable valves. CT assessment of membranous septal anatomy provides unique pre-procedural information about the patient-specific propensity for the risk of AV block.  相似文献   

18.
《Artery Research》2014,8(3):88-97
BackgroundWe explored the relationship between QRS characteristics and myocardial phenotype by delayed-enhancement cardiac magnetic resonance (DE-CMR) in patients with coronary heart disease (CHD).Methods and resultsEighty five consecutive patients with CHD that were referred for DE-CMR evaluation constituted the study population. Of a total of 1445 left ventricular (LV) segments evaluated, 346 (23.9%) segments had fibrosis.Compared to patients without pathological Q waves, patients with pathological Q waves showed a higher number of segments with fibrosis (5.9 ± 3.1 vs. 2.7 ± 2.8, p < 0.001), and lower left ventricular ejection fraction (LVEF) (42.9 ± 13.6% vs. 51.8 ± 18.3, p = 0.01); whereas no significant differences were observed regarding LV size.When discriminated in according to the QRS duration tertiles, no significant differences were observed regarding the number of segments with fibrosis (p = 0.34), whereas the highest QRS tertile was related to the presence of a low LVEF (p = 0.005) and larger LV size (p = 0.01). QRS fragmentation (fQRS), defined as the presence of an R′ or notching in the nadir of the R wave or the S wave, or the presence of >1 R′ in 2 contiguous leads, was significantly related to LV size (LV end diastolic volume 153.6 ± 81.6 ml, vs. 111.5 ± 41.4 ml, p = 0.003), function (LVEF 43.2 ± 15.9% vs. 53.6 ± 16.3%, p = 0.005), and extent of fibrosis (5.1 ± 3.4 segments vs. 3.2 ± 3.1 segments, p = 0.01).ConclusionsIn the present study, fQRS was the only QRS-derived variable systematically and more closely related to LV size, LV systolic function, and to the presence and extent of fibrosis.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号