首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 234 毫秒
1.
目的:比较自动验光仪、角膜曲率计及角膜地形图测量角膜曲率的效果。方法选取大港油田总医院123例(123眼)白内障患者,分别用三种仪器测量角膜曲率,记录3次平均角膜曲率。结果角膜地形图自动验光仪测量角膜曲率K 1平均值为(42.75±1.45)D,K 2平均值为(43.65±1.44)D;自动验光仪测量角膜曲率K 1平均值为(42.95±1.14)D,K 2平均值为(43.55±1.04)D;角膜曲率计测量角膜曲率K 1平均值为(43.05±2.27)D,K 2平均值为(43.85±1.94)D。经单因素方差分析,组间差异无统计学意义(F=3.01,2.96,P〈0.05)。结论三种方法测量角膜曲率差异无统计学意义。对于翼状胬肉,大散光或者角膜屈光手术后的角膜曲率测量,推荐使用角膜地形图。  相似文献   

2.
①目的 测量中老年白内障病人的角膜厚度、前房深度、晶体厚度及角膜曲率 ,为角膜屈光手术提供确切的解剖基础。②方法 采用进口A型超声、角膜测厚及角膜曲率仪对中老年白内障病人 10 99只眼的角膜厚度、前房深度、晶体厚度及角膜曲率进行检测并统计分析。③结果 角膜中央厚度为 (5 0 5 .0 0± 4 2 .38) μm ,下方为(6 4 8.4 3± 76 .80 ) μm ,鼻侧为 (6 2 7.4 4± 99.0 5 ) μm。前房中央深度为 (2 .913± 0 .4 6 5 )mm。晶体厚度为 (4 .5 5 2±0 .90 1)mm。角膜曲率 :水平径线 (HK) (94 4 .0 93± 1.74 7)D ,垂直径线 (VK) (4 4 .134± 1.6 13)D。角膜中央厚度男女之间有差别 (t=2 .793,P <0 .0 1)。前房深度与角膜中央厚度呈正相关 (r =0 .138,P <0 .0 5 ) ,与晶体厚度呈负相关 (r =- 0 .2 90 ,P <0 .0 0 1) ,角膜曲率HK与VK呈正相关关系 (r =0 .6 85 ,P <0 .0 0 1)。④结论 该测量可为眼前节疾病的诊断及角膜屈光、青光眼、白内障等手术提供解剖参考。  相似文献   

3.
目的 :通过测量近视眼的角膜屈光力、眼轴和角膜中央厚度 ,分析角膜屈光力、眼轴和角膜中央厚度与近视程度的关系。方法 :在进行PRK治疗的患者中 ,根据屈光度将 2 78例 (538只眼 )患者分成低、中、高和超高度四组 ,应用角膜地形图仪测定角膜屈光力 ,A型超声波测定眼轴及角膜中央厚度 ,数据用Exce 197软件计算处理。结果 :垂直径角膜屈光力 (4 4 0 1± 1 54D)明显大于水平径角膜屈光力 (4 3 10± 1 4 0D) ,P <0 .0 1。 (角膜总屈光力与屈光度的大小无关 ) ;角膜中央厚度与屈光度的大小无关 ,各屈光度组间差异无显著性。眼轴随屈光度的增大而延长 ,差异非常显著。结论 :在近视眼中 ,眼轴起着决定性的作用 ,度数越高 ,眼轴越长 ,而角膜屈光力不起作用或作用甚微。角膜中央厚度与近视程度无关。  相似文献   

4.
目的;探讨角膜曲率计,角膜地形图仪对白内障患者术前角膜曲率检测的对比分析。方法:选取该院白内障术前患者58例(102眼)分别使用角膜曲率计及角膜地形图仪测量角膜中央曲率的最大值、最小值及散光轴位。结果:两种检测仪所测得的角膜曲率的最大值、最小值、散光度数、平均膜曲率值及散光轴位均无显著性差异(P>0.05)。结论:角膜曲率计与角膜地形图仪对白内障术前中央角膜曲率测量具有相似的临床价值。  相似文献   

5.
角膜缘干细胞分布变化对角膜曲率的影响   总被引:1,自引:1,他引:0  
目的 研究上下方角膜缘上皮非对称性损害对角膜曲率的影响。方法 将兔的 11 1点方位的角膜缘上皮保留 ,其他方位角膜缘在外围保留 0 2mm宽的上皮带 ,其余上皮全部刮除 ,造成角膜上下方干细胞储备的差异。采取角膜地形图测量、组织学等方法观察角膜形态变化。结果 角膜中央区出现锥形凸起 ,锥形凸起处屈光值 (5 7 2 5± 2 73屈光度 )比术前角膜对应点屈光值 (5 2 2 3± 1.91屈光度 )明显增大 ,差异有显著意义 (P <0 0 1) ,组织学观察角膜锥形凸起处有代偿性增生的上皮细胞团。结论 角膜中央代偿性上皮增生可以显著地改变角膜曲率 ,角膜缘干细胞的分布异常是造成角膜中央上皮代偿性增生的原因之一。  相似文献   

6.
目的比较LASIK手术前后ORBSCAN-Ⅱ角膜地形图仪与超声波角膜测厚仪所测角膜厚度的差异,为再手术提供依据。方法对21例(41只眼)接受再次LASIK手术者,用ORBSCAN-Ⅱ角膜地形图仪和A超分别测量受术前后的角膜中央厚度,测定手术前后角膜曲率,比较分析结果。结果术前超声波测得角膜厚度为(544.33±29.68)μm,ORB-SCAN-Ⅱ测量角膜厚度为(548.58±30.89)μm,两者之间无显著性差异(P>0.05)。术后超声波测得角膜厚度为(544.33±29.68)μm,ORBSCAN-Ⅱ测量角膜厚度为(548.58±30.89)μm,A超测量结果为两者之间差异显著(P<0.05)。结论手术前ORBSCAN-Ⅱ角膜地形图仪与超声波角膜测厚度仪对角膜中央厚度的测量有较高的一致性,但术后,角膜表面的球面及曲率改变后二者所测值有差异。  相似文献   

7.
目的:探讨翼状胬肉切除术与角膜屈光变化的关系。方法:对4 3例翼状胬肉患者,术前术后经常规视力、角膜曲率及电脑验光检查,并且测量胬肉侵入角膜缘的长度,比较手术前后屈光度的改变。结果:4 6眼角膜曲率检查平均散光,术前为4 .87±2 .81D ,术后一周及一个月分别为3.19±2 .2 3D及2 .74±2 .0 1D ,术后较术前散光减少,差异具有显著性意义(一周时t=2 .5 83,P <0 .0 5 ;一个月时t=3.4 6 ,P <0 .0 1)。胬肉所致角膜散光以顺规性远视散光为主,散光度数与胬肉侵入角膜长度呈正相关。结论:翼状胬肉可引起角膜散光,手术切除可减少散光,提高视力。  相似文献   

8.
为对比周边加深与不加深的放射状角膜切开术 (radialkeratotomy ,RA)矫正近视的效果 ,对 2组 2 9例 39眼进行回顾分析。结果显示 ,术后 2年同一深度组等效球镜下降 ( 4 .7± 0 .7)D ,角膜屈光力下降 ( 4 .5± 0 .8)D ;周边加深组等效球镜下降 ( 5 .0± 1 .2 )D ,角膜屈光力下降 ( 4 .4± 1 .3)D。 2组病人等效球镜及角膜屈光力下降平均值无明显差异 (P >0 .0 5 )。提示 :角膜周边加深与不加深RK的术后效果无明显差异。  相似文献   

9.
目的: 选取偏高角膜曲率及正常角膜曲率伴近视眼进行临床对比分析.方法: 选取偏高角膜曲率伴近视眼男15例27眼,女14例26眼,正常角膜曲率伴近视男与女各15例30眼(采用计算机辅助角膜地形图测量偏高角膜曲率为46.02~47.82 D,正常角膜曲率为41.35~45.61 D,且角膜地形图均未提示有圆锥角膜的近视眼),对两组资料的屈光度及角膜地形图、角膜厚度、角膜散光、眼压进行统计学处理.结果: 偏高角膜曲率与正常角膜曲率伴近视眼的角膜厚度、眼压统计学上有显著差异,两组最大子午线屈光力(Simk1)、与其呈垂直子午线屈光力(Simk2)及最小子午线屈光力(Mink)有显著性差异,但两组屈光度、角膜散光(△k)、角膜表面规则性指数(SRI)及角膜表面非对称性指数(SAI)在统计学上无显著性差异.结论: 偏高角膜曲率伴近视眼的角膜厚度及眼压值均低于正常角膜曲率伴近视眼.  相似文献   

10.
角膜曲率对准分子激光屈光性角膜切削术手术效果的影响   总被引:1,自引:0,他引:1  
梁琼  曾怡谋  罗雄伟  黄玲 《河北医学》2001,7(6):497-499
目的 :探讨角膜曲率对角膜屈光手术效果的影响及近视患者角膜曲率的部分规律。方法 :检查所有手术眼术前角膜曲率 ,按角膜曲率的高低分为 10组 ,分析对比每一组的人数、手术效果 ;对比分析所有术眼术前两眼曲率差值。结果 :①发现近视眼角膜角膜曲率的分布曲线。②各个组别的近视眼手术后达到或超过术前最佳矫正视力的百分比近似。③双眼的角膜曲率的差值最小为 0D ,最大为 0 .75D ,平均为 0 .2 6± 0 .2 2D。结论 :①角膜曲率的高低对准分子激光屈光性角膜切削术的疗效没有影响。②近视眼的角膜曲率分布有一定的规律。③双眼角膜曲率差值小。  相似文献   

11.
Background  Corneal curvatures measured by conventional instruments after refractive surgeries were greater than the real values. This study on the instruments and methods for measuring corneal curvature was carried out with the aim of determining an accurate, simple and effective method to evaluate corneal refractive power after radial keratotomy (RK).
Methods  A retrospective study was carried out on 52 eyes of 42 patients with a history of RK. The postoperative measurements after RK were performed with a manual keratometer (Rodenstock, Munchen-Hamburg, Germany), a corneal topographer (Tomey TMS-1) and an automated IOLMaster keratometer (Carl Zeiss GmbH, USA). The results obtained from analyzing clinical histories (clinical history method, CHM) were compared to the postoperative measurements with a two-way analysis of variance. Adjusted keratometry was used to correct the corneal central refractive power (K) values of the three keratometers. The CHM results were also compared to the corrected K values obtained with the three keratometers using the same statistical method.
Results  The smallest mean value was found for the CHM ((36.61±2.23) diopters). The K values obtained with the CHM were very different from the results obtained with the three different instruments. The corrected K values obtained with the IOLMaster were the closest to the K values from the CHM.
Conclusions  It was shown that K values from measurements with the three instruments were higher. When the power of the intraocular lens of the patients after RK was calculated, the errors of the K values measured with the instruments should be taken into consideration.
  相似文献   

12.
目的 对比IOLMaster 700、OPD-ScanⅢ与MODi 2角膜地形图仪3种仪器在测量白内障患者水平角膜直径(white to white,WTW)、平坦轴角膜曲率(keratometry of flataxial,Kf)和陡峭轴角膜曲率(keratometry of steepaxial,Ks)的差异性和一...  相似文献   

13.
目的〓〖HTK〗了解青少年近视患者角膜高阶像差的分布规律,探讨近视程度对角膜高阶像差的影响。〖HTW〗方法〓〖HTK〗应用Ray Tracing原理设计的iTrace视功能分析仪检测104例104只青少年近视眼,等效球镜为[(-3.98±2.50)D]的角膜像差。在6mm瞳孔直径下测量3~6阶Zernike系数,计算各阶均方根(RMS)值、3~6阶总RMS值、球差(Z04,Z06)及彗差(Z-13,Z13,Z-15,Z15)RMS值,并分别与屈光度进行相关分析。〖HTW〗结果〓〖HTK〗受试者球镜平均为(-3.72±2.36)D,柱镜平均为(-0.77±0.62)D,角膜总高阶像差(3~6阶)的RMS值平均为(0.413±0.134)μm,3阶至6阶的各项Zernike系数大致呈递减趋势(4阶球差Z04除外),所有角膜的Z04(4阶球差)值均为正值,平均(0.272±0.086)μm。近视屈光度大小与角膜总高阶像差、各阶像差的RMS值无相关性,但水平彗差(Z13)与等效球镜呈负相关(P<0.01)。彗差作为主导像差的频率在高度近视组略增加,而球差是角膜像差中最主要的像差(约占80%),且不随屈光度的变化而变化。〖HTW〗结论〓〖HTK〗在青少年近视中,角膜高阶像差的个体差异较大,仅个别Zernike系数与近视程度有相关性,球差是角膜像差中最主要的像差。  相似文献   

14.
目的:通过对比光学相干生物测量仪(IOL Master)与A超联合角膜地形图测量人工晶体度数的精确性,探讨两种测量方法在临床应用中的差异。方法选取2010年3月至2011年9月中南大学湘雅医院眼科行白内障超声乳化吸取联合人工晶体(IOL)植入术的白内障患者60例(84眼),其中年龄相关性白内障42例(57眼),并发性白内障18例(27眼),分为IOL Master组和A超联合角膜地形图测量组。术前IOL Master组使用IOL Master测量眼轴长度和角膜曲率,采用Haigis、SRK/T等公式计算IOL度数,同时使用A超联合角膜地形图测量眼轴长度和角膜曲率,采用SRK/Ⅱ公式计算IOL度数;术前A超联合角膜地形图测量组使用A超联合角膜地形图测量眼轴长度和角膜曲率,采用SRK/Ⅱ公式计算IOL度数。术后3个月复查两组患者的屈光状态,计算绝对屈光误差(MAE),并对以上结果进行统计学分析。结果⑴IOL Master组,术前IOL Master和A超测得的眼轴长度比较差异无统计学意义( P >0.05),但是在眼轴长度>26 mm患者中,两种检查方法检测眼轴长度[(28.53±0.57)mm vs (29.42±0.64)mm]比较差异有统计学意义( P <0.05);IOL Master和角膜地形图测得的角膜曲率[(42.12±0.31)D vs (43.09±0.27)D]比较差异有统计学意义( P <0.01);IOL Master和A超联合角膜地形图测量计算的IOL度数平均值[(17.06±0.48)D vs (16.37±0.56)D]比较差异有统计学意义( P <0.05)。⑵术后3个月IOL Master组和A超联合角膜地形图测量组的MAE[(0.07±1.05)D vs (0.16±0.81)D]比较差异有统计学意义( P <0.05)。结论在正常眼轴白内障患者,IOL Master与A超联合角膜地形图对于眼轴测量及IOL度数测算具有高度一致性,但在高度近视白内障患者,IOL Master对于眼轴测量及IOL度数测算精确性更高。  相似文献   

15.
目的检测中国歼击机飞行员视觉及相关角膜参数,并与低度近视眼行准分子激光角膜屈光手术后的数据进行对比分析,评估准分子激光角膜屈光手术在我空军应用的前景。方法选取进行准分子激光原位角膜磨镶术(LASIK)或角膜表面切削手术(PRK)的低度近视眼,分别观察裸眼视力、屈光状态、Astramax角膜地形图获得的波阵面像差,即总高/低阶像差、垂直彗差、水平彗差和球差,以及角膜前表面Q值、角膜曲率等角膜参数,与歼击机飞行员正视眼数据进行对比分析。结果PRK和LASIK治疗≤-3.00D轻度近视眼,术后裸眼视力达到飞行员的标准;屈光状态,即球镜度数、柱镜度数、等效球镜三组差异无统计学意义;手术组角膜的Q值没有改变;中央角膜曲率显著下降;术后总高/低阶像差和球差与飞行员组差异有统计学意义。LASIK术后球差的增加显著高于PRK。结论 低度近视眼行PRK或LASIK术后裸眼视力、屈光状态、角膜的Q值可以达到飞行员的标准。但总高阶像差、彗差和球差的增加可能严重影响视觉质量,LASIK较PRK对球差的影响更大。在选拔飞行员时,对做过角膜屈光手术的患者应该慎重。同时在屈光手术中如何减少和避免波阵面像差的改变,如何通过手术保持和提高视觉质量也是我们今后的课题。  相似文献   

16.
目的探讨招飞体检中角膜地形图的应用。方法对招飞体检中发现的低角膜曲率23例46眼进行Astramax角膜地形图检查,分析角膜地形图获得的角膜形态及测量参数,包括中央角膜曲率、Q值(瞳孔中心4.5mm直径范围)、高阶像差数据等。结果确诊5例10眼进行过准分子激光角膜屈光手术,4例8眼可疑接受过角膜塑形术治疗。结论在招飞体检中角膜地形图检查是筛查异常角膜的有效方法之一。  相似文献   

17.
唐卓 《右江医学》2005,33(2):112-113
目的 探讨准分子激光角膜原位磨镶术(LASIK)对角膜内皮的影响。方法 将行LASIK术患者60例116眼,分为A组38例73眼(未配戴角膜接触镜组),B组22例43眼(戴角膜接触镜组)。两组激光切削深15~150μm,平均激光切削深度 86.23±22.31μm, 术前及术后3个月进行角膜内皮显微镜检查,观察角膜内皮细胞密度、形态。分析切削深度与角膜内皮密度的相关性。结果 ①A组术前角膜内皮密度与术后3个月角膜内皮密度无显著性差异(t=0.329,P>0.05)。②B组术后 3个月平均角膜内皮密度明显高于术前,有显著性差异(t=3.859,P<0.01)。术后角膜内皮形态无明显改变。③A组角膜切削深度与角膜内皮细胞密度无显著相关性(r=0.0321,P>0.05)。结论 LASIK术后早期不引起中央部角膜内皮细胞密度和形态改变。  相似文献   

18.
巩膜环扎外加压术对角膜前表面屈光性状的影响   总被引:2,自引:0,他引:2  
目的探讨巩膜环扎外加压术后角膜前表面屈光性状改变的规律.方法采用前瞻性自身对照研究,对30例(30眼)因孔源性视网膜脱离接受巩膜环扎外加压术的患者在术前l d、术后1周、1个月和3个月,分别用OrbscanⅡ角膜地形图仪检测术眼的角膜前表面屈光度、散光度、散光轴向和不规则散光度,并分析不同手术因素对角膜前表面屈光性状的影响.结果巩膜环扎外加压术引起角膜前表面周边部术后1周屈光度显著减小(P<0.01);中央部散光度显著增加;散光轴向向加压块中点轴向偏移,术后1周中央部与术前比较差异具有显著性(P<0.05);不规则散光度变化差异无显著性.手术中环扎带的长度和加压块的宽度与各屈光参数的变化有显著相关性.结论巩膜环扎外加压术后的角膜前表面屈光改变以短期为主.医生在手术操作中应尽量减小对角膜形状的改变,以保证术后的视觉恢复.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏