首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.

Study Design

Prospective cohort.

Introduction

Clinical studies that evaluate the correlation between associated lesions of the triangular fibrocartilage complex (TFCC) and outcome of distal radial fractures expressed with the patient-rated disability are missing.

Purpose of the Study

To evaluate the outcomes of distal radius fractures associated with or without an injury of the TFCC.

Methods

Patients undergoing operative treatment for distal radial fracture were prospectively enrolled (n = 70). The TFCC was examined by wrist arthroscopy, and injuries were classified according to Palmer. Comparative analyses were performed on data from 45 patients with TFCC injury (the injured group) and 25 patients with an intact TFCC (the intact group). The outcome measures included The Patient-Rated Wrist Evaluation (PRWE) and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaires, 3 and 12 months after injury.

Results

The TFCC was injured in 45 patients (64%). In patients with an intact TFCC, the mean total PRWE score was 27 (at 3 months) and 16 (at 12 months), whereas in patients with TFCC injury, it was 40 (at 3 months) and 24 (at 12 months). Mean DASH scores were 26 and 13 for the intact group and 39 and 27 for the injured group at 3 and 12 months, respectively. PRWE and DASH results showed significant difference at 3 and 12 months when compared using the Mann-Whitney test.

Conclusions

Disability outcomes were worse in patients with distal radial fracture where TFCC was injured. TFCC injuries are an important cofactor affecting the outcome of distal radial fractures.  相似文献   

2.
BackgroundTriangular fibrocartilage complex (TFCC) injury is common in distal radius fractures. The purpose of this study was to compare the conservative and surgical treatments of TFCC injury of the wrist associated with distal radius fractures.MethodsA retrospective study was conducted on 39 patients who received treatment for TFCC injury with distal radius fractures. All patients were treated using a volar locking plate for distal radius fractures. Twenty-six patients who received conservative treatment for TFCC through long arm splinting were classified into group 1, and 13 patients who received surgical treatment for TFCC were classified into group 2. The splint was maintained for 6 weeks in both groups. For clinical evaluation, the range of motion (ROM) of the wrist joint, patient-rated wrist evaluation (PRWE) score, Disabilities of the Arm, Shoulder and Hand (DASH) score, and grip strength were measured. Distal radioulnar joint (DRUJ) stability was evaluated through a stress load test and graded between grade 0 and 3 intraoperatively after fixation and at the final follow-up.ResultsIn group 1, the average DASH score was 11.1 ± 4.4, the average PRWE score was 10.2 ± 4.6, the grip strength was 89.4% relative to the unaffected side, the average ROM of the wrist joint was 65° ± 7.0° for extension, 51.5° ± 8.1° for flexion, 86° ± 5.1° for supination, and 85° ± 5.2° for pronation, and DRUJ stability at the final follow-up was grade 0 in 58.62%, grade 1 in 31.03%, grade 2 in 10.34%, and grade 3 in 0%. In group 2, the average DASH score was 13 ± 5.0, the average PRWE score was 12.4 ± 3.7, the grip strength was 87.3% relative to the unaffected side, and the average ROM of the wrist joint was 60° ± 9.8° for extension, 53.1° ± 7.0° for flexion, 85° ± 5.3° for supination, and 86.8° ± 4.5° for pronation. At the final follow-up, DRUJ stability was grade 0 in 66.67%, grade 1 in 25%, grade 2 in 8.3%, and grade 3 in 0%. The 2 groups showed no statistically significant differences in DASH score, PREW score, grip strength, ROM, and final follow-up DRUJ stability.ConclusionsThere were no statistically significant differences in the clinical outcomes between the surgical and conservative treatment groups. Therefore, when normal radiological indices are achieved after treatment of distal radius fractures, DRUJ stability can be obtained by conservative treatment.  相似文献   

3.
Background and purpose Promising results have been reported after volar locked plating of unstable dorsally displaced distal radius fractures. We investigated whether volar locked plating results in better patient-perceived, objective functional and radiographic outcomes compared to the less invasive external fixation.

Patients and methods 63 patients under 70 years of age, with an unstable extra-articular or non-comminuted intra-articular dorsally displaced distal radius fracture, were randomized to volar locked plating (n = 33) or bridging external fixation. Patient-perceived outcome was assessed with the Disability of the Arm, Shoulder, and Hand (DASH) questionnaire and the Patient-Rated Wrist Evaluation (PRWE) questionnaire.

Results At 3 and 6 months, the volar plate group had better DASH and PRWE scores but at 12 months the scores were similar. Objective function, measured as grip strength and range of movement, was superior in the volar plate group but the differences diminished and were small at 12 months. Axial length and volar tilt were retained slightly better in the volar plate group.

Interpretation Volar plate fixation is more advantageous than external fixation, in the early rehabilitation period.  相似文献   

4.
《Injury》2017,48(3):731-737
IntroductionMalunion occurs in approximately 23% of non-operatively treated and 11% of operatively treated distal radius fractures. The decision whether to correct a malunion is primarily based on functional impairment and wrist pain. The purpose of this study was to assess the long-term functional outcomes of corrective osteotomies for symptomatic malunited distal radius fractures.MethodsAll consecutive corrective osteotomies of the distal radius performed in one centre between January 2009 and January 2016 were included. The primary outcome was the functional outcome assessed with the Disability of the Arm, Shoulder and Hand (DASH) and the Patient-Rated Wrist Evaluation (PRWE) score. Secondary outcomes were range of motion, grip strength, pain as indicated on the Visual Analogue Scale (VAS) before and after corrective osteotomy, radiological parameters, time to union and complications. Additionally, we aimed to determine if there were any difference in graft versus no graft usage.ResultsA total of 48 patients were included. The median age was 54.5 years (IQR 39–66) and 71% was female. The median time to follow-up was 27 months. The median DASH and PRWE score were respectively 10.0 (IQR 5.8–23.3) and 18.5. (6.5–37.0). Except for pronation and supination, range of motion and grip strength of the injured wrist were significantly less compared to the uninjured side. Palmar and dorsal flexion and radial and ulnar deviation of the injured wrist were significantly less compared with the uninjured side. VAS pain scores decreased significantly from 6.5 preoperative to 1.0 postoperative. The median time to union was 23 weeks (IQR 12–29.5). Eighteen patients (38%) had a complication for which additional treatment was required. Except for a significant difference in radial inclination and length after the corrective osteotomy in favour of graft usage, there were no significant differences between graft an no graft usage.ConclusionsCorrective osteotomy is an effective method of treating symptomatic distal radius malunions with good long-term functional results, measured with the DASH and PRWE score, and improvement in radiographic parameters and pain scores. Additionally, no differences in functional outcomes were found between graft and no graft usage.  相似文献   

5.
《Arthroscopy》2003,19(5):511-516
Purpose: This study reviews the results of acute repair of peripheral ulnar-sided triangular fibrocartilage complex (TFCC) detachment associated with intra-articular distal radius fractures. Type of Study: Two-year follow-up of patients who had undergone acute TFCC repair. Methods: Fifty-six patients underwent arthroscopically assisted treatment of intra-articular distal radius fractures using external fixation and adjunctive percutaneous pinning between 1994 and 1998. Thirteen patients with an acute, complete tear of the ulnar attachment of the TFCC were treated using arthroscopic repair of the TFCC in addition to stabilization of the radius fracture. All patients were evaluated at a mean of 24 months (range, 17 to 35 months) with a physical examination, wrist radiographs, and a Disability of Arm, Shoulder, and Hand (DASH) module outcome assessment questionnaire. Results: Average wrist flexion, extension, pronation, and supination were 67.3, 61.8, 79.1, and 86.8, respectively. The average grip strength was 78% of the uninjured side. The results of the Gartland and Werley grading system were good to excellent in 12 patients and fair in 1 patient. The DASH outcome scores revealed a mean functional score of 13 and a mean athletic score of 12. None of the patients reported ulnar-sided pain at follow-up. Conclusions: Arthroscopically assisted TFCC repair in conjunction with distal radius fixation resulted in a high degree of patient satisfaction and good to excellent clinical outcomes.Arthroscopy: The Journal of Arthroscopic and Related Surgery, Vol 19, No 5 (May-June), 2003: pp 511–516  相似文献   

6.
PURPOSE: The purpose of this study was to determine if malalignment after extra-articular distal radius fractures influenced patient-reported pain and disability at 1 year and to investigate how this relationship changes with age. METHODS: Two hundred sixteen subjects with extra-articular distal radius fractures were followed. The influence of specific radiographic parameters and the overall "acceptability" of alignment on Patient-Rated Wrist Evaluation (PRWE) and Disabilities of Arm, Shoulder and Hand (DASH) scores were assessed. The relative risk (RR) of a poor outcome in the presence of malalignment of the distal radius at various ages was calculated; the RR was then used to calculate a number needed to harm. RESULTS: Malalignment of the distal radius was associated with higher reports of pain and disability in patients <65 years of age. In patients aged > or =65 years, no isolated radiography parameter was found to affect PRWE or DASH scores significanly; however, there was an increased risk of a poor outcome in fractures with malalignment when compared with fractures with acceptable alignment in all age groups. The RR of a poor outcome with malalignment showed a decreasing trend with increasing age, with a significant reduction after 65 years. In patients > or =65 years of age, 8 malaligned fractures would require correction to prevent 1 poor outcome (based on DASH, or 9 based on PRWE); in younger patients, only 2 malaligned fractures would need correction to avoid 1 poor outcome (based on DASH, or 3 based on PRWE). CONCLUSIONS: Patients > or =65 years of age showed no statistically significant relationship between malalignment of the distal radius and PRWE or DASH scores when the radiography parameters were examined in isolation and when clustered together. The relative risk data demonstrates, however, that patients at all ages have a higher risk of a poor outcome with malalignment of the distal radius when compared with those with acceptable alignment. Therefore, we conclude that the relationship between outcome and alignment of the radius should not be considered as an all-or-none phenomenon but rather considered as a decreasing gradient of risk, with the most significant change seen after patients reach 65 years of age.  相似文献   

7.
《Injury》2016,47(2):372-376
The optimal management of distal radius fractures remains controversial. The aim of this study was to compare the radiographic and functional outcomes of 318 patients who underwent k-wire fixation or volar plating for fractures of the distal radius. Patients were aged between 20 and 65 years and followed for a mean of 32 months. The mean values for volar tilt, radial inclination, radial length and ulnar variance were all significantly better in the volar plate group. Malunion occurred in 13.2% of patients undergoing k-wiring and 4% of patients treated with a volar plate (p < 0.007). Higher values for radial inclination, radial length and volar tilt correlated with better functional outcome as measured by disabilities of the arm shoulder and hand (DASH) and patient rated wrist evaluation (PRWE) scores. Lower values for ulnar variance correlated with better functional outcome. Although volar plate treatment resulted in a superior radiological outcome, there was no evidence that this translated into a superior functional outcome (DASH 13.12 vs. 11.25, p = 0.28) (PRWE 17.56 vs. 16.31, p = 0.69). The k-wiring procedure remains a suitable inexpensive option for simple fractures. Volar plating should be reserved for complex fractures that cannot be reduced by closed means.  相似文献   

8.
Study designClinical measurements. Longitudinal.PurposeTo translate and cross-culturally adapt the original patient-rated wrist evaluation (PRWE) into a Korean version (K-PRWE), and to measure the reliability, validity, and responsiveness of the K-PRWE for the evaluation of distal radius fractures (DRFs).MethodsK-PRWE was developed by forward and backward translations of the PRWE and resolution of cultural discrepancies. Sixty-three DRF patients that underwent open reduction and volar plate fixation completed the K-PRWE at 3 months and 6 months postoperatively. Grip strength, wrist range of motion, VAS for wrist pain and the Korean version of DASH were performed at 3 months postoperatively. Reliability was measured by determining test-retest reliability (intraclass correlation coefficient) and internal consistency (Cronbach's alpha coefficient). Criterion and construct validity testing was performed using Spearman's correlation test. Responsiveness was evaluated using effect size (ES) and standardized response mean (SRM).ResultsCronbach's alpha coefficient and the intraclass correlation coefficient of the K-PRWE were 0.94 and 0.96, respectively, which indicated that the internal consistency of the questionnaire items was sound and reliable. The correlation coefficient between K-PRWE and K-DASH scores was 0.74 and between K-PRWE and VAS scores was 0.69. Responsiveness was good with an ES of 0.84 and an SRM of 0.89.ConclusionsThe Korean version of the PRWE was found to be reliable, valid, and responsive to evaluate the pain and disability associated with distal radius fractures.  相似文献   

9.
An increase of distal radius fractures was seen in 2009 when an extended cold spell allowed natural ice skating in Amsterdam. This resulted in overload of our Emergency Departments and operating rooms. This study reports patient and fracture characteristics of these injuries. We also determined potential skating-related risk factors. All patients who sustained a distal radius fracture during natural ice skating between January 3 and January 12, 2009 were included. Patient and fracture characteristics, treatment, validated outcome (Quick DASH) at 3 months after injury were determined. Natural ice skating accounted for a 5.5-fold increase of distal radius fractures (92 fractures) compared to a similar time period without natural ice skating in 2008. Fracture types were AO-type A, n = 50, type B, n = 11 and type C, n = 31. Twenty-eight patients were casted without reduction. Fifty-four patients underwent at least one reduction before casting. The non-operative group consisted of 67 patients (68 fractures, male/female 18/49) with an average age of 55.5 years. Twenty-three patients (24 fractures) underwent internal fixation. Quick DASH for the whole group was a mean of 23.1 points (range 0–95). The mean Quick DASH for the non-operatively treated group was 19.9 points (range 0–95), for the operatively treated group 31.7 points (range 2–65). Distal radius fractures increased 5.5-fold during a period with natural ice skating. Women aged 50 and over were predominantly affected. Most fractures were extra-articular, and the vast majority was treated non-operatively. Utilization of wrist-protecting devices should be considered during future natural ice periods.  相似文献   

10.
《Journal of hand therapy》2020,33(3):314-319
Study DesignA prospective cohort single-center study.IntroductionSelf-efficacy (SE) refers to beliefs in ones capabilities to organize and execute the courses of action required to produce given goals. High SE is an important factor for recovery from injury/illness; people who believe in their capability will more likely reach a good outcome.Purpose of the StudyThe aim of this study was to examine if SE has an effect to physical functioning, pain and patient-rated wrist function three months postoperatively in patients undergoing plating due to a distal radius fracture.MethodsSixty-seven patients undergoing plating for a distal radius fracture rated SE at the first appointment with the physiotherapist. At the three-month follow-up, the following assessments were administered: Patient-Rated Wrist Evaluation (PRWE), pain-scores, hand grip strength, and range of motion.ResultsThe group with a high SE showed significantly better range of motion for flexion (P = .046) and supination (P = .045), hand grip strength (P = .001) and PRWE scores (P = .04). The NRS pain during activity was lower, although not significantly lower (P = .09). Using Spearman's rank correlation coefficient, there was a moderate correlation between SE and pain during activity, wrist flexion, and PRWE score.DiscussionSE corresponds to wrist function after combined plating of distal radius fractures.ConclusionMeasurement of SE could possibly be useful to identify patients in special need of support during the postoperative rehabilitation.  相似文献   

11.
Distal radius fractures are common injuries; however, identifying which factors are responsible for predicting outcomes remains an area of controversy. The purpose of this study was to define factors predictive of patient-reported pain and disability at 1 year in a prospective cohort of extra-articular distal radius fractures (n = 222). Data were collected at the initial visit and after 3, 6, and 12 months. The primary outcome was the 1-year patient-rated wrist evaluation (PRWE) score. The effect of baseline patient and injury characteristics on the 1-year PRWE score was assessed. Univariate and forward stepwise regression analyses both agreed that the most influential predictor of pain and disability at 1 year was injury compensation. The 1-year PRWE score was significantly higher for subjects involved with third-party claims (35.48) compared to those that were not involved in any claims (14.97), p = 0.006. The regression model found that three baseline factors – injury compensation, education, and other medical comorbidities – explained 16.4% of the variance in PRWE scores at 1 year. No injury characteristic, including the degree of initial fracture displacement, was found to significantly influence the 1-year PRWE score. This study has shown that baseline patient and injury characteristics play a small role in predicting 1-year patient-reported pain and disability in extra-articular distal radius fractures. Conceptual factors outside of this biomedical model should be investigated.  相似文献   

12.
Background

To evaluate the functional and radiographic outcomes, as well as the treatment costs, of closed displaced intra-articular distal radius fractures treated with either open reduction internal fixation (ORIF) with volar locking plates or nonoperative treatment with plaster cast immobilisation.

Materials and methods

A total of 60 patients (32 receiving ORIF, 28 receiving nonoperative treatment) with closed intra-articular distal radius fractures were included. The mean age was 52.1 and 57.4, respectively. Functional and radiographic assessments were carried out at 12 months post-injury. Patients’ treatment costs, median salaries and lengths of medical leave were obtained.

Results

DASH and MAYO wrist score in the ORIF group did not differ significantly from those in the nonoperative group. Apart from superior ulnar deviation in the ORIF group (p = 0.0096), differences in the range of motion of the injured wrists were not significant. Similarly, there were no significant differences in grip strength and visual analog scale for pain. Volar tilt (p = 0.0399), radial height (p = 0.0087), radial inclination (p = 0.0051) and articular step-off (p = 0.0002) were all significantly superior in the ORIF group. There was a 37-fold difference in mean treatment costs between ORIF (SGD 7951.23) and nonoperative treatment (SGD 230.52).

Conclusion

Our study shows no difference in overall functional outcomes at 12 months for closed displaced intra-articular distal radius fractures treated with either ORIF with volar locking plates or plaster cast immobilisation, and this is independent of radiographic outcome. A longer follow-up, nevertheless, is needed to determine whether the development of post-traumatic arthritis will have an effect on function. The vast difference in treatment costs should be taken into consideration when deciding on the treatment option.

Level of evidence

Level 3.

  相似文献   

13.
Purpose: Comminuted intraarticular distal radial fractures are difficult to treat conservatively and require operative treatment. This study compared the functional outcomes between variable angle volar plating and external fixator with K-wire augmentation in open reduction and internal fixation. Methods: A total of 62 adult patients with comminuted intraarticular distal radius fracture were randomized into 2 groups: volar plate group and external fixator group. These patients aged between 18 and 60 years had unilateral fractures, and agreed to be included in the study. Patients with a history of fracture, bilateral fracture, associated other injuries, delayed injury for more than 2 weeks, open fracture, pre-existing arthrosis or disability, psychiatric illness and pathological fracture were excluded. Patients were followed up at 6 weeks, 3 months, 6 months and 1 year. The assessment of pain, functional activity, range of motion and grip strength was done at each stage of follow-up. The pain and functional activities were assessed by patient rated wrist evaluation (PRWE) score and disabilities of the arm, shoulder and hand (DASH) score. Results: Patients in volar plate group had superior PRWE score and DASH score at each stage of followup. At 1 year follow-up, the mean PRWE score were 7.48 for volar plate group and 7.35 for external fixator group; while the mean DASH score was 4.65 for volar plate group and 5.61 for external fixator group. They had better flexion and extension range of movement. They also had better pronation and supination range of motion at initial follow-up, however the difference get attenuated by 1 year. Volar plate group had significantly better grip strength than external fixator group. Complication rates were higher in external fixation group. Conclusion: Fixation with variable angle volar plate results in early wrist mobilization, better range of movement, less pain and disability and early return of function.  相似文献   

14.
《Acta orthopaedica》2013,84(3):360-364
Background and purpose Mechanisms of injury to ulnar-sided ligaments (stabilizing the distal radioulnar joint and the ulna to the carpus) associated with dorsally displaced distal radius fractures are poorly described. We investigated the injury patterns in a human cadaver fracture model.

Methods Fresh frozen human cadaver arms were used. A dorsal open-wedge osteotomy was performed in the distal radius. In 8 specimens, pressure was applied to the palm with the wrist in dorsiflexion and ulnar-sided stabilizing structures subsequently severed. Dorsal angulation was measured on digitized radiographs. In 8 other specimens, the triangular fibrocartilage complex (TFCC) was forced into rupture by axially loading the forearm with the wrist in dorsiflexion. The ulnar side was dissected and injuries were recorded.

Results Intact ulnar soft tissues limited the dorsal angulation of the distal radius fragment to a median of 32o (16–34). A combination of bending and shearing of the distal radius fragment was needed to create TFCC injuries. Both palmar and dorsal injuries were observed simultaneously in 6 of 8 specimens.

Interpretation A TFCC injury can be expected when dorsal angulation of a distal radius fracture exceeds 32o. The extensor carpi ulnaris subsheath may be a functionally integral part of the TFCC. Both dorsal and palmar structures can tear simultaneously. These findings may have implications for reconstruction of ulnar sided soft tissue injuries.  相似文献   

15.
PURPOSE: The purpose of this study was to compare the outcomes of 2 treatments for unstable distal radius fractures: open reduction internal fixation (ORIF) through a volar approach with a fixed-angle implant and a standard external fixation (EF) method. METHODS: This study included patients with comminuted unstable intra-articular and extra-articular distal radius fractures treated by a single surgeon. Data were gathered retrospectively on 11 patients treated with EF who had been followed up for an average of 47 months (range, 12-84 mo). Prospective data were gathered on 21 patients who were treated with ORIF through a volar approach with a fixed-angle implant. Follow-up evaluation for this group averaged 17 months (range, 12-24 mo). The 2 groups were compared for range of motion (ROM), strength, and functional outcome as measured by the Patient Rated Wrist Evaluation (PRWE) and the Disability of the Arm, Shoulder, and Hand Questionnaire (DASH). Fracture reduction was evaluated from radiographs taken at the last follow-up visit and compared between groups. RESULTS: The mean passive wrist ROM at the final follow-up evaluation in EF patients was 59 degrees extension and 57 degrees flexion, compared with 63 degrees extension and 64 degrees flexion in patients treated with ORIF. Passive pronation/supination arc of motion was similar for the 2 groups, as were the DASH and PRWE scores. Grip strength as a percentage of the opposite wrist was significantly greater in the external fixation group, a possible consequence of longer follow-up evaluation. Final radiographic measurements for the EF group averaged 5 degrees volar tilt and 25 degrees radial inclination, with 2.2-mm ulnar-positive variance. The ORIF with volar plating group averaged 10 degrees volar tilt and 22 degrees radial inclination, with .5-mm ulnar-negative variance. Radial length and volar tilt were significantly greater for the ORIF group. The average final intra-articular step-off was significantly different, with 1.4-mm step-off in the EF group and .4 mm in the ORIF group. CONCLUSIONS: The use of ORIF with a volar fixed-angle implant resulted in stable fixation of the distal articular fragments, allowing early postsurgical wrist motion. The PRWE and DASH scores for the groups were equivalent, whereas intra-articular step-off, volar tilt, and radial length were better in the ORIF group. There were few complications, implant removal was not necessary, and early postsurgical wrist ROM was initiated without loss of reduction.  相似文献   

16.
Objective:Metaphyseal-diaphyseal fractures of the distal radius are a major treatment dilemma and orthopaedic surgeons have to pay due consideration to restoration of anatomy of distal radius together with rotation of the radial shaft and maintenance of radial bow and interosseous space.We performed this study to evaluate the clinic-radiological outcome of metaphyseal-diaphyseal fractures of the distal radius treated with long volar locking plates.Methods:This prospective study involved 27 patients (22 males and 5 females) with metaphyseal-diaphyseal fracture of the distal radius.Their mean age was (30.12±11.48) years (range 19-52 years) and the follow-up was 26.8 months (range 22-34 months).All patients underwent open reduction and internal fixation with a long volar locking plate.According to AO/OTA classification,there were 7 type A3,13 type C2 and 7 type C3 fractures.Subjective assessment was done based on the disabilities of the arm,shoulder and hand (DASH) questionnaire.Functional evaluation was done by measuring grip strength and range of motion around the wrist and the radiological determinants included radial angle,radial length,volar angle and ulnar variance.The final assessment was done according to Gartland and Werley scoring system.Results:Postoperative radiological parameters were well maintained throughout the trial,and there was significant improvement in the functional parameters from 6 weeks to final follow-up.The average DASH scores improved from 37.5 at 6 weeks to 4.2 at final follow-up.Final assessment using Gartland and Werley scoring system revealed 66.67%(n=l8) excellent and 33.33% (n=9) good results.There was one case of superficial infection which responded to antibiotics and another carpel tunnel syndrome which was managed conservatively.Conclusion:Volar locking plate fixation for metaphyseal-diaphyseal fractures of distal radius is associated with excellent to good functional outcome,early rehabilitation and minimal complications.  相似文献   

17.
《Journal of hand therapy》2014,27(3):177-184
Study designProspective cohort.IntroductionEffects of patient-centered care on distal radius fracture recovery lacks evidence.Purpose of the studyTo understand from the perspective of a patient with a distal radius fracture: if the Patient Perception of Patient-Centeredness Questionnaire (PPPC) subscales apply to distal radius fracture populations; the strongest and weakest areas of patient-centered care; changes in patient perceptions of patient-centeredness during recovery; and, correlations between aspects of patient-centered care and patient reported pain and disability.MethodsPatients with distal radius fractures (n = 129; mean age = 54.03, SD = 14.63) completed the Patient Rated Wrist Evaluation (PRWE) and PPPC, at baseline (less than 10 days post-fracture) and at three months post-injury. Outcome measure responses were factor analyzed and tested for correlations.ResultsFactors identified were titled Clinician-Patient Dialogue, representing communication components of patient-centered care, and Clinician-Patient Alliance, representing partnership components of patient-centered care. Small significant correlations (r = 0.22) between PRWE and PPPC responses were observed with Clinician-Patient Alliance more correlated at baseline and Clinician-Patient Dialogue at follow-up.DiscussionImportant aspects of the patient-clinician dynamic were identified.ConclusionsCommunication between clinician and patient was perceived most favorably at baseline; and partnership improved by three months.Level of evidence1b.  相似文献   

18.
《Injury》2022,53(10):3344-3351
IntroductionDistal radius fractures are the most frequent upper limb injuries encountered by orthopedic surgeons. Surgical treatment of distal radius fractures is preserved for unstable and displaced fractures. A randomized controlled trial was conducted to compare the radiological and functional outcomes of bridge plating (BP) to external fixation (EF) in comminuted intra-articular distal radius fractures.MethodsSixty patients with distal radius fractures were eligible for treatment by means of ligamentotaxis using either a dorsal bridge plate (30 patients) or an external fixator (30 patients) with or without supplementary Kirschner wires (K-wires). Radiological evaluation was done using the radial inclination angle, radial length, and the volar tilt. Clinical evaluation was performed using ranges of wrist motion, grip strength, Visual Analogue Scale (VAS), and a validated Arabic version of the Disability of the Arm, Shoulder, and Hand (DASH) questionnaireResultsPatients were followed up for 12 months. No significant difference was found in terms of radiographic parameters or ranges of wrist motion. At 3-months follow-up, bridge plating group had stronger grip strength, lower Disability of the Arm, Shoulder, and Hand scores, and lower Visual Analogue Scale. However, both groups had similar functional outcomes at last follow-up. External fixation group had a higher rate of postoperative complications.ConclusionIn comparison to external fixation, bridge plating may provide earlier functional recovery with lower complication rates. However, no functional or radiological superiority were demonstrated at 12-months follow-up.  相似文献   

19.

Background and purpose

Mechanisms of injury to ulnar-sided ligaments (stabilizing the distal radioulnar joint and the ulna to the carpus) associated with dorsally displaced distal radius fractures are poorly described. We investigated the injury patterns in a human cadaver fracture model.

Methods

Fresh frozen human cadaver arms were used. A dorsal open-wedge osteotomy was performed in the distal radius. In 8 specimens, pressure was applied to the palm with the wrist in dorsiflexion and ulnar-sided stabilizing structures subsequently severed. Dorsal angulation was measured on digitized radiographs. In 8 other specimens, the triangular fibrocartilage complex (TFCC) was forced into rupture by axially loading the forearm with the wrist in dorsiflexion. The ulnar side was dissected and injuries were recorded.

Results

Intact ulnar soft tissues limited the dorsal angulation of the distal radius fragment to a median of 32o (16–34). A combination of bending and shearing of the distal radius fragment was needed to create TFCC injuries. Both palmar and dorsal injuries were observed simultaneously in 6 of 8 specimens.

Interpretation

A TFCC injury can be expected when dorsal angulation of a distal radius fracture exceeds 32o. The extensor carpi ulnaris subsheath may be a functionally integral part of the TFCC. Both dorsal and palmar structures can tear simultaneously. These findings may have implications for reconstruction of ulnar sided soft tissue injuries.A complex of ligaments on the ulnar side of the wrist supports the stability of the ulnocarpal and the distal radioulnar (DRU) joints. Included in this are the extensor carpi ulnaris (ECU) subsheath and the triangular fibrocartilage complex (TFCC), which is further subdivided into the radioulnar ligaments (RULs), the ulnotriquetral ligament (UT), and the ulnolunate (UL) ligament (Garcia-Elias 1998, Berger 2001). Injuries to the TFCC are common in dorsally angulated fractures of the distal radius fracture (Colle''s fracture) and may adversely affect functional outcome (Lindau et al. 2000). The pathomechanics of these injuries are poorly studied, however.During wrist arthroscopy, we have observed two lesions that are often present when treating TFCC lesions associated with distal radius fractures: (1) a separation of the floor of the ECU tendon sheath from the TFCC, and (2) an injury to the foveal insertion of the TFCC into the ulna. It seems probable that there must be a limit to how much the distal radius fragment can be displaced without rupture of the TFCC or fracture of the ulna.We investigated the characteristics of a TFCC injury in a cadaveric fracture model of dorsally displaced fractures. We hypothesized that (1) a TFCC lesion can be expected at a certain degree of displacement and that (2) a rupture of the foveal insertion would begin in the palmar capsule and progress dorsally, due to the dorsal displacement of the distal radius fragment.  相似文献   

20.
BACKGROUND: Surgical treatment of unstable distal radius fractures does not always yield a satisfactory outcome. The several surgical strategies available have problems associated with them. This study was undertaken to determine if volar locking plate fixation could be useful for treating unstable distal radius fractures. METHODS: This retrospective follow-up study assessed 24 fractures in 24 patients with unstable distal radius fractures surgically treated with one of three volar locking plate systems. According to the AO classification system, 7 patients had type A3 fractures, 5 patients had type C2 fractures, and the remaining 12 patients had type C3 fractures. Radiographic measurements included volar tilt, radial inclination, and ulnar variance. Clinical outcomes were evaluated by active range of motion of the wrist and forearm, grip strength, Saito's wrist score, and the Japanese Society for Surgery of the Hand version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (JSSH version of the DASH). RESULTS: At the time of final follow-up (5 months minimum) the mean volar tilt was 8.1 degrees , radial inclination was 20 degrees, and ulnar variance was 0.4 mm. Mean wrist extension measured 61 degrees, wrist flexion 55 degrees, radial deviation 23 degrees, ulnar deviation 35 degrees, pronation 87 degrees, and supination 87 degrees. Grip strength recovered to a mean of 84% of the grip strength in the contralateral limb for patients who had injured their dominant hand and to a mean of 73% for patients who had injured their nondominant hand. Saito's wrist score calculations revealed 20 excellent and 4 good results. The mean DASH disability/symptom score was 9.9 points, and the mean DASH work module score was 8.2 points. CONCLUSIONS: The present study demonstrated that unstable distal radius fractures could be successfully treated with volar locking plate systems.  相似文献   