首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Transient-evoked otoacoustic emissions (TEOAEs) were recorded from more than 30000 newborns over a six year period. Analysis was performed on all the TEOAEs that passed the bedside universal hearing screen (n=60431), in order to characterize the normal properties of neonatal TEOAEs and to study ear and sex effects. Short recording times (median=33 s) were observed in combination with high entire TEOAE level (median=18.8 dB SPL for an 81.8 dB SPL peak stimulus), and high reproducibility (median=86%). Signal-to-noise ratio (S/N) of the TEOAE was highly frequency-dependent, being poorer at low frequencies. Prolonged averaging increased median reproducibility to 97%, but the minor S/N-improvement at low frequencies did not justify the longer test time. Highly significant mean lateral asymmetries (right >left) and sex differences (female >male) existed in entire TEOAE level, S/N TEOAE, and in half-octave frequency bands (700–4000 Hz). Mean lateral and sex entire TEOAE level differences were 1.1 dB and 1.3 dB, respectively. Stimulus levels were not affected by ear or sex. Hence, physiological differences at the level of organ of Corti were demonstrated in newborns.  相似文献   

2.
OBJECTIVE: Early diagnosis and rehabilitation of congenital hearing loss are mandatory in order to achieve a satisfactory linguistic and cognitive development. A universal hearing screening in order to identify congenital hearing losses before 3 months of age is required. METHODS: TEOAEs are an easy to perform, short lasting, not invasive and low-cost test with a high sensitivity. 320 at term new-borns (640 ears) without any risk factor for hearing loss underwent TEOAEs. The new-borns were screened 3 days after birth. Those who failed the first test were retested when possible before the discharge from the hospital. ABR was performed 3 months later in cases who failed TEOAE. RESULTS: The median TEOAE sampling time was 98 s, the median test duration was 14 min. The mean stimulus amplitude was 80 dB peSPL in the left ear and 81 dB peSPL in the right ear, noise levels within the external meatus during sampling were 44 dB SPL on the right ear and 43 dB SPL on the left one, noise contained within the response (A-B difference) was 8.65 dB SPL in the left ear and 8.74 dB SPL in the right ear, mean TEOAEs amplitudes were 21.49 dB SPL and 21.78 dB SPL in the right and left ear respectively, the mean lower and upper limit of the spectrum being 678 and 5720 Hz. According to these criteria 494/640 ears (77.2%) passed the test at the first recording, while TEOAEs resulted to be absent in 146/640 ears (22.8%). A retest was performed successfully before the discharge from the Hospital in 30/640 ears (4.7%). An ABR recording within the third month of life was scheduled as out-patient in the 58 new-borns (116 ears, 18.2%) who failed the test. 18 of them (36 ears, 5.6%) did not complete the program, 19 new-borns (38 ears, 11.8%) showed a normal ABR, while two new-borns (four ears, 0.6%) failed ABR after 3 months. A second ABR performed after 6 months was normal. CONCLUSIONS: TEOAEs recording seems at now the test of choice for a universal hearing screening. However, a greater standardization of criteria both in performing the test and in evaluating the results is needed.  相似文献   

3.
新生儿与成人瞬态诱发耳声发射差异的频谱特性分析   总被引:1,自引:0,他引:1  
目的 比较新生儿与成人瞬态诱发耳声发射(TEOAE)的差异,并分析其频谱特性.方法 以短声刺激分别对120名通过听力筛查的新生儿(男58,女62)和32名平均纯音听阈(听力级)在20 dB以内的成年人(男15,女17)行TEOAE检测,对于测试结果 行频谱分析和半倍频程分析.结果 ①新生儿组TEOAE总强度(声压级,下同)为(15.18±4.39)dB,高于成人组的(9.51±4.12)dB,差异具有统计学意义(t=9.303,P<0.05).②新生儿的频带重复率、频带重复率非0比例、频带信噪比检出率及频带信噪比在第1频带(0.8 kHz)最低,在3.2 kHz最大;而成人在第5频带(4.0 kHz)处最低,在1.5 kHz最大.③新生儿与成人最大频带信噪比强度差为7.09 dB,二者出现的频率位置相差约1.7 kHz.④半倍频程分析显示新生儿TEOAE最大能量为(10.50±5.09)dB,在2828 Hz处,而成人为(2.84±5.33)dB,在1414 Hz处;二者最大反应在强度上相差7.66 dB,出现的频率位置相差1414 Hz.⑤成人1.5 kHz区的TEOAE信号最强,之后其信噪比随频带增高而降低,而新生儿信噪比却呈现随频带增高而增强的特征;从第1频带到第5频带,新生儿与成人TEOAE强度的差值随频带增高也逐渐增大.结论 成人TEOAE总强度低于新生儿.新生儿频带信噪比及半倍频程能量反应峰的分布频率及反应强度均高于成人.  相似文献   

4.
目的分析自发性耳声发射(spontaneous otoacoustic emission,SOAE)与瞬态诱发性耳声发射(transient evoked otoacoustic emission,TEOAE)之间的相关性。方法新生儿112例(224耳),其中女59例,男53例,出生后2~4天内行SOAE及TEOAE检测。结果每耳SOAE信号峰数量与其TEOAE强度相关(r=0.43,P〈0.001)。每耳最大SOAE波幅与其TEOAE强度相关(r=0.49,P〈0.001)。不同耳依据其SOAE信号峰数量将其分为4组:I组无SOAE信号峰;II组为单SOAE信号峰;III组为2~3个SOAE信号峰;IV组为3个以上信号峰。I组TEOAE强度为(10.96±3.77)dBSPL,II组(12.87±3.27)dBSPL,III组(15.61±3.23)dBSPL,IV组(17.100±4.51)dBSPL,各组间的TEOAE强度差异均具有统计学意义。II组SOAE最大强度(-13.54±9.21)dBSPL,III组(-4.56±7.22)dBSPL,IV组(1.00±7.35)dBSPL,各组间最大SOAE波幅差异具有统计学意义。结论SOAE信号峰数量、最大SOAE波幅与TEOAE强度之间存在正相关关系,SOAE信号峰越多,最大SOAE波幅也越强,同时TEOAE强度也越强。  相似文献   

5.
The presentation of contralateral noise during the recording of transient evoked otoacoustic emissions (TEOAEs) reduces the amplitude of the TEOAE in normally-hearing adults. This is known as TEOAE suppression. The present study investigated TEOAE suppression in 18 adults with learning disabilities (LDs) compared to 18 adults without LDs. TEOAEs were elicited by 60 dB p.e. SPL clicks and were suppressed by the presentation of 60 dB SPL contralateral broadband noise. Suppression was measured as a change in the overall TEOAE response amplitude, and also analysed in 2-ms epochs representing different TEOAE frequency-response bands. A significant interaction was evident between group type and ear tested. Participants in the control group had right ear dominance for the suppression effect, whereas the left ear was found to be dominant for the LD group. These findings suggest a mechanism of the medial olivary cochlear bundle and efferent auditory pathway that differs in those with LD compared to those with typical learning abilities.  相似文献   

6.
The presentation of contralateral noise during the recording of transient evoked otoacoustic emissions (TEOAEs) reduces the amplitude of the TEOAE in normally-hearing adults. This is known as TEOAE suppression. The present study investigated TEOAE suppression in 18 adults with learning disabilities (LDs) compared to 18 adults without LDs. TEOAEs were elicited by 60 dB p.e. SPL clicks and were suppressed by the presentation of 60 dB SPL contralateral broadband noise. Suppression was measured as a change in the overall TEOAE response amplitude, and also analysed in 2-ms epochs representing different TEOAE frequency-response bands. A significant interaction was evident between group type and ear tested. Participants in the control group had right ear dominance for the suppression effect, whereas the left ear was found to be dominant for the LD group. These findings suggest a mechanism of the medial olivary cochlear bundle and efferent auditory pathway that differs in those with LD compared to those with typical learning abilities.  相似文献   

7.
背景噪声对新生儿瞬态诱发耳声发射的影响   总被引:2,自引:0,他引:2  
目的 分析背景噪声对新生儿瞬态诱发耳声发射(TEOAE)的影响.方法 对122例通过听力筛查的新生儿(244耳,女62例,男60例)分别以短声刺激行TEOAE检测,用quick TEOAE模式,叠加次数大于100次.并以背景噪声分组,比较安静组与噪声组之间TEOAE差异.结果 ①新生儿TEOAE的背景噪声为(33.94...  相似文献   

8.
Distortion Product Otoacoustic Emissions (DPOAE) can be used as an alternative to Transient Evoked Otoacoustic Emissions (TEOAE). This study aims to establish normal values for DPOAE in healthy newborns. DPOAE were determined with the Madsen Celesta 503 at 0.5, 1, 2, 4 and 8 kHz with an unequal stimulus level of the primaries (L1 = 65 dB SPL, L2 = 50 dB SPL). DPOAE were present in 92.4% of the ears of the 185 babies tested at 4 days after birth. The 5% quantile and the median of the DPOAE of the right and left ears were calculated for the five frequencies tested. At 4 kHz there was a significant sex effect (mean amplitude of DPOAE was higher in female than in male babies) and at 2 kHz a significant interaction effect was found between sex and side. The calculated reference limits are open to comparison with data obtained using other commercial equipment.  相似文献   

9.
Non-linear transient-evoked otoacoustic emissions (TEOAEs) at 74 dB pSPL, distortion-product otoacoustic emissions (DPOAEs) at 65/45 dB SPL and pure-tone audiometry were used to detect noise-induced, inner ear changes in a longitudinal study. Repeated-measures ANOVAs were made on the Noise (n=69) and Quiet (n=42) groups. The Noise group's hearing thresholds increased by 1.2 dB and DPOAE amplitude decreased by ?0.9 dB. For both groups, TEOAE amplitude decreased by approximately ?0.6 dB. Eight of 12 ears with permanent threshold shift (PTS) and 10 of 13 ears with temporary threshold shift (TTS) showed TEOAE decrements or low baseline TEOAE amplitudes. Fewer TTS and PTS ears also showed DPOAE decrements, and there was never a DPOAE decrement without a corresponding TEOAE decrement or low TEOAE baseline. Some TTS ears showed permanent emission decrements. Although otoacoustic emissions show promise in detecting noise-induced inner ear changes, it is premature to use them in hearing conservation programs.  相似文献   

10.
The influence of general anesthesia (GA) on transiently evoked otoacoustic emissions (TEOAEs) was studied in 19 normally hearing women undergoing surgery. Emissions were measured on the day before the operation, after premedication but before the beginning of the operation, and during and after the operation. There were no significant differences in TEOAE amplitude or in reproducibility between results obtained the day before the operation and after premedication. Ten patients received nitrous oxide (N2O) during GA (N2O group), and 9 patients did not (non-N2O group). The amplitude of TEOAEs was reduced during GA in 9 of 10 patients in the N2O group and in 7 of 9 patients in the non-N2O group. However, the average decrease of amplitude after the first 10 minutes was greater in the N2O group (4 +/- 3.4 dB) than in the non-N2O group (0.18 +/- 1.4 dB). The corresponding mean reproducibility of the response decreased in 9 of 10 patients of the N2O group (29% +/- 24%) and was nearly unchanged in the non-N2O group (2.3% +/- 7.2%). The time course of the amplitude reduction was similar in both groups. The smallest amplitudes were reached on an average by 19.3 +/- 11.4 minutes in the N2O group and by 17 +/- 13.6 minutes in the non-N2O group. Preoperative and postoperative TEOAEs were comparable in level and reproducibility. Differential frequency effects imply a middle ear effect for the greater reduction of TEOAE amplitudes in the N2O group due to gas diffusion into the middle ear.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

11.
OBJECTIVES: The objective of this study was to determine whether transient-evoked otoacoustic emissions (TEOAEs) measured in a group of normal-hearing professional singers, who were frequently exposed to high-level sound during rehearsals and performances, differed from those measured in age- and gender-matched normal-hearing non-singers, who were at minimal risk of hearing loss resulting from excessive sound exposure or other risk factors. DESIGN: Twenty-three normal-hearing singers (NH-Ss), 23 normal-hearing controls (NH-Cs), and 9 hearing-impaired singers (HI-Ss) were included. Pure-tone audiometry confirmed normal-hearing thresholds (>or=15 dB HL) at 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, and 8.0 kHz in NH-Ss and NH-Cs, and confirmed mild, high frequency, sensorineural hearing loss in HI-Ss (HI-Ss were included only to estimate sensitivity and specificity values for preliminary pass or fail criteria that could be used to help identify NH-Ss at risk for music-induced hearing loss). TEOAEs were measured twice in all ears. TEOAE signal to noise ratio (S/N) and reproducibility were examined for the whole wave response, and for frequency bands centered at 1.0, 1.4, 2.0, 2.8, and 4.0 kHz. RESULTS: Moderate to high correlations were found between test and retest TEOAE responses for the three groups. However, absolute test-retest differences revealed standard deviations that were two to three times larger than those reported previously, with the majority of the variability occurring for the 1.0 kHz band. As such, only the best TEOAE response (B-TEOAE) from the two measurements in each ear was used in further analyses, with data from the 1.0 kHz band excluded. With one exception, within-group comparisons of B-TEOAE S/N and reproducibility across ears and gender revealed no statistically significant differences for either NH-Ss or NH-Cs. The only significant within-group difference was between left and right ears of NH-C females for S/Ns measured in the 2.0 kHz band, where median responses from right ears were found to be higher than left ears. Across-group comparisons of B-TEOAEs revealed lower median S/N and reproducibility values for NH-Ss compared with NH-Cs for the whole wave response and 1.4 kHz band. For the 2.0 kHz band, reproducibility was similar for the normal-hearing groups but median S/N was found to be lower for NH-Ss. No significant differences in S/N or reproducibility were found between normal-hearing groups for the 2.8 and 4.0 kHz bands. Using data from NH-Cs and HI-Ss to establish sensitivity and specificity values for various TEOAE pass or fail criteria, six preliminary criteria were identified as having sensitivity and specificity values >or=90%. When these criteria were applied to NH-Ss, the number of NH-S ears passing ranged from 57% to 76%, depending on the criteria used to judge the NH-S ears, which translates into 24% to 43% of ears failing. CONCLUSIONS: Although TEOAE responses were measurable in all singers with normal audiometric thresholds, responses were less robust than those of NH-Cs. The findings suggest that subtle cochlear dysfunction can be detected with TEOAE measurement in a subset of normal-hearing professional singers. Although preliminary, the study findings highlight the importance of pass or fail criterion choice on the number of ears that will be identified as "at risk" for music-induced hearing loss.  相似文献   

12.
The aim of this study is to investigate the middle ear dynamic characteristics and their influence on TEOAEs in patients with middle ear disorders. The middle ear dynamic characteristics and TEOAE findings were investigated in 89 patients with middle ear disorders using the sweep frequency impedance (SFI) meter and the ILO88 system, respectively. These patients were divided into six subcategories: tympanic membrane aberrations, otitis media with effusion, chronic otitis media, tympanic membrane perforation, otosclerosis, and ossicular chain dislocation. Details of the TEOAE frequency characteristics were compared with the individual's middle ear dynamic characteristics. TEOAE status as a function of hearing threshold and middle ear dynamic characteristics was also examined. The results showed that the middle ear dynamic characteristics in patients with middle ear disorders correlated with the TEOAE frequency characteristics and amplitudes. The hearing level and middle ear mobility were the controlling factors affecting TEOAE status. Using both non-linear and linear stimulus modes, larger TEOAE responses were obtained when the hearing level was better than 20 dB HL, and there was moderately good middle ear mobility. Moreover, TEOAEs were absent using the non-linear mode when the hearing level was worse than 30 dB HL, whereas with the linear mode. TEOAEs were recordable even with hearing losses of up to 40 dB HL in patients with middle ear disorders. A higher incidence of recordable TEOAEs was found in the subgroups with tympanic membrane abnormalities and secretory otitis media when compared with the other subgroups. No TEOAEs were recordable in patients with chronic otitis media.  相似文献   

13.
Non-linear transient-evoked otoacoustic emissions (TEOAEs) at 74dB pSPL, distortion-product otoacoustic emissions (DPOAEs) at 65/45dB SPL and pure-tone audiometry were used to detect noise-induced, inner car changes in a longitudinal study. Repeated-measures ANOVAs were made on the Noise (n=69) and Quiet (n=42) groups. The Noise group's hearing thresholds increased by 1.2 dB and DPOAE amplitude decreased by -0.9 dB. For both groups, TEOAE amplitude decreased by approximately -0.6 dB. Eight of 12 ears with permanent threshold shift (PTS) and 10 of 13 ears with temporary threshold shift (TTS) showed TEOAE decrements or low baseline TEOAE amplitudes. Fewer TTS and PTS ears also showed DPOAE decrements, and there was never a DPOAE decrement without a corresponding TEOAE decrement or low TEOAE baseline. Some TTS ears showed permanent emission decrements. Although otoacoustic emissions show promise in detecting noise-induced inner ear changes, it is premature to use them in hearing conservation programs.  相似文献   

14.
The ear vulnerability of a group of combat soldiers was tested. The study initially included 84 soldiers and lasted two years. The soldiers were exposed to the noise of small-arms fire. Measurements included transient-evoked otoacoustic emissions (TEOAE) and pure-tone audiometry. Measurements, initially performed prior to the soldiers' basic training, were repeated several times during the study. In general, TEOAE levels (Em) decreased over time. About 57% of the ears developed a slight hearing loss (SHL) after two years of noise exposure. We define SHL as a threshold shift of 10 dB or greater, in at least at one of the audiometric frequencies 1000, 2000, 3000, 4000, or 6000 Hz. About 63% of the tested ears that had medium TEOAE level (1 or =8 dB SPL), less than 30% developed SHL. We suggest a prediction for ear vulnerability on the basis of Em prior to noise exposure.  相似文献   

15.
Our objectives were 1) to determine whether transiently evoked otoacoustic emissions (TEOAEs) are affected by the status of the tympanic membrane (TM) and middle ear (ME) as determined by clinical examinations and tympanograms; 2) to determine the efficacy of TEOAEs in detecting hearing loss; and 3) to determine the relative effects of the ME status and hearing loss on TEOAEs. In a prospective observational study in a tertiary care children's hospital, 89 patients (169 ears; 9 ears eliminated from analyses) were examined by 2 attending pediatric otolaryngologists for otologic conditions and underwent audiologic evaluations including TEOAEs from August 1994 through May 1995. The main outcome measures were presence or absence of TEOAE whole reproducibility (WR) and reproducibility (R) at 2 kHz. Statistical analyses showed that of the 8 ME and TM conditions evaluated (normal, TM perforation, pressure equalization [PE] tube, TM retraction, tympanosclerosis, TM atrophy, ME effusion, surgery other than PE tube insertion), only the presence of ME effusion and normal examination findings had a significant effect on the results of WR and R at 2 kHz. Of the 6 different types of tympanograms evaluated (A, B, C, AD, As, B with large volume), type A, B, and C tympanograms had a significant effect on WR and types A and B had a significant effect on R at 2 kHz. Hearing losses > or = 25 dB hearing level (HL) at any of the 5 frequencies (0.25, 0.5, 1, 2, and 4 kHz) were well predicted by the absence of WR and R at 2 kHz. When clinical examination and impedance data were evaluated simultaneously with hearing status, hearing status had a greater effect on WR and R at 2 kHz. We conclude that type B and C tympanograms and the presence of ME effusion (which reflect abnormal ME status) have an adverse effect on TEOAEs. However, the presence of hearing loss is the most significant predictor of TEOAE results. The TEOAE WR and R at 2 kHz are effective in identifying patients with normal hearing and with hearing losses > or = 25 dB HL.  相似文献   

16.
Great potential has recently been demonstrated for the application of transient evoked otoacoustic emissions (TEOAEs) in screening the hearing of school-aged children. The present study aimed to describe the range of TEOAE values obtained from a large cohort of 6-year-old children in school settings. Results indicated significant sex and ear asymmetry effects on signal-to-noise ratio, response, whole wave reproducibility, band reproducibility and noise levels. A prior history of ear infections was also shown to influence response level, whole wave reproducibility and band reproducibility. The sex, ear and history specific normative data tables derived may contribute to future improvements in the accuracy of hearing screening for 6-year-old school children.  相似文献   

17.
This study was designed to investigate the effect of various durations of noise exposure in animals on physiological responses from the cochlea which are also used clinically in humans: auditory brainstem response (ABR), transient evoked otoacoustic emissions (TEOAEs) and distortion product otoacoustic emissions (DPOAEs). Rats were exposed to 113 dB SPL broad-band noise (12 h on/12 h off) for durations of 3, 6, 9, 12, 15 and 21 days, and tested 24 h after cessation of the noise and again after a period of 6 weeks. ABR threshold to click stimuli and to a 2-kHz tone burst (TB), TEOAE energy content and DPOAE amplitude in the exposed rats were compared to those in a group of control rats not exposed to noise. ABR thresholds (click and TB) were significantly elevated in all exposure duration groups compared to control rats. DPOAE amplitudes and TEOAE energy content were significantly reduced. The mean ABR thresholds following 21 days exposure were significantly greater (click = 100 dB pe SPL; TB = 115 dB pe SPL) than those following 3 days exposure (click = 86 dB pe SPL; TB = 91 dB pe SPL). Linear regression analysis between recorded responses and duration of noise exposure (days) showed a significant increase in ABR thresholds of approximately 0.8-- 1.4 dB/day. TEOAE and DPOAE responses showed no such dependence on noise duration and were already maximally reduced after only 3 days of exposure. This can be explained by the possibility that short noise exposures may cause damage to the early, more active stages of cochlear transduction (as shown by TEOAEs and DPOAEs). As the noise exposure continues, further damage may be induced at additional, later stages of the cochlear transduction cascade (as shown by ABR). Thus, ABR seems more sensitive to noise duration than OAE measures.  相似文献   

18.
A non-linear technique is predominantly used for the recording of transiently-evoked otoacoustic emissions (TEOAEs). The aim of this study was to compare linear and non-linear TEOAE recordings. TEOAEs were recorded in 22 normal hearing subjects to clicks from 90 to 30 dB SPL in 10 dB steps with the ILO88 system using both linear and non-linear recording techniques. The non-linear recording technique reduces stimulus artifacts for early latencies, but total elimination could not be proved. Both artifact reduction and significant differences between the two kinds of TEOAE recordings were reduced for longer latencies and lower stimulus intensities. For longer latencies (>10 ms) there was no significant difference between "linear" and "non-linear" TEOAEs. A higher signal-to-noise ratio was found for "linear" TEOAEs, resulting in better identification and a higher test-retest correlation. The linear recording technique, which includes new methods of artifact cancellation in comparison to the mainly utilized non-linear recording technique, should be used especially in hearing screening.  相似文献   

19.
The ototoxic effects of cisplatin in a Sprague–Dawley rat model were evaluated by recordings of auditory brainstem responses (ABR) and transiently evoked otoacoustic emissions (TEOAEs). The ABR responses were evoked from alternating clicks and 8, 10, 12, 16, 20 and 30 kHz tone pips in a range from 40 to 100 dB SPL range. The TEOAEs were recorded with a non-linear protocol, and were evoked by a 63.5 dB SPL click stimulus. Twenty five male Sprague–Dawley rats were used in the study, 20 animals were treated with cisplatin (16 mg/kg, body weight) and five animals served as controls. The data showed that 72 h after the cisplatin administration, the TEOAE and ABR variables were significantly altered. The relationship between the ABR and TEOAE variables was shown to be non-linear. The most significant relationships were observed between the TEOAE correlation and the ABR threshold values at 10, 12, and 16 kHz.  相似文献   

20.
Researchers have recently reported the effects of age, sex, ear asymmetry, and subject's activity status on transient evoked otoacoustic emissions (TEOAEs). The present study aimed to expand upon such reports by describing the characteristics of TEOAE spectra obtained from a cohort of 607 two-month-old infants in community child health clinics. Results indicated significant sex, ear and activity state effects on the signal:noise ratio, response, whole wave and band reproducibility values. These findings suggest the need for TEOAE normative data to be expressed as a function of sex, ear, and activity state of infants. These characteristics of TEOAE spectra may shape future investigations into appropriate pass fail criteria for two-month-old infants.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏