首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Stress-gated technetium-99m (Tc-99 m) sestamibi single-photon emission computed tomography (SPECT) is used to risk stratify patients after acute myocardial infarction (AMI). In clinical practice, results of this test are used primarily to identify patients with myocardial ischemia for intervention. The value of this test to risk stratify patients with AMI not at high ischemic risk has not been addressed. More than 1-year follow-up was undertaken in 124 patients who underwent predischarge gated Tc-99m sestamibi SPECT studies and who did not undergo subsequent revascularization. Clinical variables and test-derived variables were evaluated to predict cardiac death, recurrent AMI, and hospitalization for unstable angina, congestive heart failure, or coronary revascularization. Independent predictors by multivariate analysis for cardiac death or recurrent AMI were a history of prior AMI (relative risk [RR] = 5.32, confidence interval [CI] 2.17 to 12.96), a low exercise capacity (RR = 6.84, CI 1.99 to 23.48), and left ventricular (LV) ejection fraction (EF) <40% (RR = 2.63, CI 1.04 to 6.38). The incidence of cardiac death or recurrent AMI was 29.8% in patients with a low exercise capacity versus 4.5% in those with good exercise capacity, and 38.1% in patients with LVEF <40% versus 9.4% in those with LVEF >40%. Independent predictors of cardiac death, AMI, or hospitalization for unstable angina, congestive heart failure, or revascularization were a history of prior AMI (RR = 2.24, CI 1.11 to 4.50) and LVEF <40% (RR = 3.13, CI 1.64 to 5.95). Among patients followed after AMI without revascularization Tc-99m sestamibi SPECT can identify a high-risk subset. The strongest independent predictors are poor exercise capacity and LVEF < 40%.  相似文献   

2.
Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi   总被引:7,自引:0,他引:7  
Most reports to date using single photon emission computed tomography (SPECT) with technetium-99m (Tc-99m) sestamibi have used acquisition parameters that were optimized for thallium-201. To fully utilize the superior imaging characteristics of Tc-99m sestamibi, there is a need to optimize the technical aspects of SPECT imaging for this agent. Performance can be enhanced through the careful selection of optimal radiopharmaceutical doses, imaging sequences, acquisition parameters, reconstruction filters, perfusion quantification methods and multidimensional methods for visualizing perfusion distribution. The current report describes theoretical considerations, phantom studies and preliminary patient results that have led to optimized protocols, developed at Emory University and Cedars-Sinai Medical Center, for same-day rest-stress studies, given existing instrumentation and recommended dose limits. The optimizations were designed to fit a low-dose-high-dose rest-stress same-day imaging protocol. A principal change in the acquisition parameters compared with previous Tc-99m sestamibi protocols is the use of a high-resolution collimator. The approach is being developed in both prone and supine positions. A new method for extracting a 3-dimensional myocardial count distribution has been developed that uses spherical coordinates to sample the apical region and cylindrical coordinates to sample the rest of the myocardium. New methods for visualizing the myocardial distribution in multiple dimensions are also described, with improved 2-dimensional, as well as 3- and 4-dimensional (3 dimensions plus time) displays. In the improved 2-dimensional display, distance-weighted and volume-weighted polar maps are used that appear to significantly improve the representation of defect location and defect extent, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
B P Mandalapu  M Amato  H G Stratmann 《Chest》1999,115(6):1684-1694
Like 201Tl imaging, technetium Tc 99m sestamibi (MIBI) myocardial imaging can be used with exercise and pharmacologic testing to assess the presence of coronary artery disease. An increasing body of literature indicates that MIBI can also be used to assess risk of future cardiac events such as myocardial infarction or death. This article summarizes the current status of MIBI imaging for evaluating prognosis in patients with known or suspected coronary artery disease.  相似文献   

4.
5.
Real-time myocardial contrast echocardiography (MCE) has the potential to evaluate myocardial perfusion and wall motion (WM) simultaneously. The purposes of this study were to correlate the diagnostic value of MCE with radionuclide single-photon emission computed tomography (SPECT), and to assess the sensitivity and specificity of real-time MCE in detecting coronary artery disease (CAD). Seventy patients with clinically suspected CAD underwent MCE and SPECT at baseline and after dipyridamole infusion. Segmental perfusion with MCE using low mechanical index after 0.3–0.4-ml bolus injections of perfluorocarbon exposed sonicated dextrose albumin solution was performed. All patients had a dual-isotope (rest thallium-201, stress sestamibi) study performed both at baseline and after dipyridamole infusion, and 40 patients had subsequent quantitative coronary angiography. Abnormalities were noted in 27 patients (38.6%) by MCE, in 29 patients (41.4%) by WM analysis, and in 30 patients (42.9%) by SPECT imaging. When MCE and WM analysis were combined, the agreement with SPECT imaging improved from 75.7% (Kappa = 0.50) to 82.0% (Kappa = 0.62). In 40 patients (120 territories) who underwent coronary angiography, good perfusion concordance was achieved for the left anterior descending and left circumflex arteries, and was fair for the right coronary arteries. Compared with quantitative angiography, there was no difference in sensitivity, specificity, and accuracy in detecting significant CAD among the three modalities. The combination of MCE and WM had a better sensitivity (84%), specificity (93.3%), and accuracy (87.5%) than the MCE and WM analysis alone. However, the difference did not reach statistical significance. Real-time MCE has a good agreement with SPECT imaging for detecting CAD. The combination of MCE and WM appears to have higher sensitivity, specificity, and accuracy in detecting CAD than either technique alone.  相似文献   

6.
The authors compared retrospectively the diagnostic accuracy of three protocols--201Tl stress-redistribution, 2-day 99mTc-tetrofosmin and the dual-isotope protocol (rest 201Tl/stress99m Tc-tetrofosmin)--for the detection of ischaemic heart disease (IHD) in a total of 115 patients without previous myocardial infarction (IM). 201Tl protocol (group A) was used to examine 43 patients, incl. 15 women, mean age 51 years (38-69 years). The 2-day 99m Tc-tetrofosmin protocol was used to examine 39 patients incl. 12 women, mean age 49 years (30-71 years). The dual-isotope protocol was used in 33 patients, incl. 8 women, mean age 52 years (31-69 years). In all patients coronarography was performed, stenosis of the artery >50% was considered significant for IHD. The sensitivity of the dual-isotope protocol was 95% and 96% resp. and 92% in the 2-day tetrofosmin and 201Tl protocol, (p>0.05). The specificity of the dual-isotope protocol was 82% and 89% resp. and 88% in the 201Tl and 2-day tetrofosmin protocol, (p >0.05). The diagnostic accuracy was 91% in the dualisotope and 201Tl protocol and 92% in the 2-day protocol (p>0.05). No significant difference was revealed in the sensitivity, specificity and diagnostic accuracy for the detection of IHD between different protocols in patients without previous IM.  相似文献   

7.
Technetium-99m (Tc-99m) sestamibi imaging at rest has been used to detect and localize myocardial infarction. The largest study to date is a cooperative study of 146 patients in 17 institutions. There were 24 normal subjects and 122 patients with documented myocardial infarction based on clinical, enzymatic or electrocardiographic criteria. The presence of segmental myocardial perfusion defects was compared to the presence of a Q wave on the electrocardiogram or wall motion abnormality on gated blood pool scans, performed within 48 hours of the Tc-99m sestamibi study. Of the 122 infarct patients, 118 (97%) showed perfusion abnormalities by Tc-99m sestamibi imaging. A perfusion defect was found in 110 (99%) of 111 patients with a Q wave and a wall motion abnormality, 113 (99%) of 114 patients with a wall motion abnormality and 113 (98%) of 115 patients with a Q wave. Of the 24 normal subjects, 22 (92%) had normal Tc-99m sestamibi images. In 75% of 1,986 segments, both a Tc-99m sestamibi defect and a regional wall motion abnormality on gated blood scans were present. In 11% of segments, wall motion was normal but Tc-99m sestamibi imaging was abnormal; in 14% of segments, wall motion was abnormal and Tc-99m sestamibi images were normal. In the 24 control subjects, 99% of the segments were normal. Thirty-eight patients had coronary angiography. A close relation existed between the coronary anatomy and myocardial Tc-99m sestamibi uptake. All 9 territories supplied by an occluded vessel and poor collaterals had grade 0 uptake (scale 0 to 2: 0 = markedly reduced; 2 = normal).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
OBJECTIVES. The purpose of the present study was to compare single-photon emission computed tomographic (SPECT) myocardial images of technetium-99m (Tc-99m) sestamibi and thallium-201 (Tl-201) isotopes in the same dog undergoing partial coronary occlusion during pharmacologic vasodilation. BACKGROUND. To date, no controlled study has been reported comparing SPECT Tc-99m sestamibi with SPECT Tl-201 imaging during stress with anatomic and physiologic standards. METHODS. Mongrel dogs were anesthetized with chloralose and instrumented to record left anterior descending coronary blood flow and aortic pressure. Partial coronary occlusion with a hydraulic cuff reduced coronary vascular conductance, which is equal to the coronary blood flow normalized to aortic pressure during peak vasodilation with intravenous adenosine. Each dog received 5 mCi of Tl-201, then 30 mCi of Tc-99m sestamibi during partial coronary occlusion at peak vasodilation. Tomographic myocardial imaging was performed in a 180 degrees anterior arc scan for 33.5 min, first with Tl-201, and later, without moving the dog, for 33.5 min with Tc-99m sestamibi. Postmortem staining defined the region underperfused because of its dependence on the artery that was partially occluded. RESULTS. In seven dogs with moderate reduction in coronary blood flow, coronary vascular conductance decreased with partial coronary occlusion (47 +/- 12%) during Tl-201 imaging and (47 +/- 8%, p = NS) during Tc-99m sestamibi imaging. The underperfused region was 23.9 +/- 6.4% of total left ventricular mass. Counts in the defects were 39% higher (0.86 +/- 0.08 of normal counts) for Tc-99m sestamibi than for Tl-201 (0.64 +/- 0.09 of normal counts, p < 0.001), and the defect on SPECT Tc-99m sestamibi images occupied only a fraction (0.37 +/- 0.30) of the area of the defect on the Tl-201 images of the same dog. Bull's-eye displays constructed from the pathologic slices showed that the Tl-201 defect size was closer to the underperfused region of the left ventricular mass determined pathologically than was the Tc-99m sestamibi defect size. In four additional dogs a severe, near total coronary occlusion was created during Tl-201 and Tc-99m sestamibi administration. In these dogs, similar defect contrast (0.55 +/- 0.12 vs. 0.62 +/- 0.09, p = NS) and areas (0.18 +/- 0.07 vs. 0.18 +/- 0.11, p = NS) were observed with Tl-201 and Tc-99m sestamibi, respectively. CONCLUSIONS. Tomographic myocardial imaging with Tc-99m sestamibi during moderately severe partial coronary occlusion underestimated the area of the defect relative to Tl-201 or to the pathologic reference standard in dogs. Defect contrast was sharper with tomographic myocardial Tl-201 than with tomographic myocardial Tc-99m sestamibi during moderately severe partial coronary occlusion.  相似文献   

9.
Objectives. This study compares technetium-99m sestamibi (sestamibi) electrocardiographic (ECG) gated single-photon emission computed tomography (gated SPECT) and echocardiography for the evaluation of myocardial function and assesses the feasibility of single-injection, single-acquisition stress perfusion/rest function technetium-99m sestamibi-gated SPECT as an alternative to conventional stress/rest imaging for assessment of myocardial perfusion and viability.Background. Simultaneous assessment of stress perfusion and rest function is possible with gated SPECT acquisition of stress-injected technetium-99m sestamibi.Methods. Rest thallium-201 SPECT followed by stress sestamibigated SPECT (acquired 0.5 to 1 h after sestamibi injection) was performed in 58 patients. Echocardiography was performed immediately after or before gated SPECT in 43 of the patients. All studies were analyzed by semiquantitative visual scoring. Sestamibi-gated SPECT studies were read for stress perfusion and rest wall motion and thickening. Reversibility on sestamibi-gated SPECT was defined as the presence of a definite stress defect with normal or mildly impaired wall motion or thickening on gated SPECT.Results. There was high segmental score agreement between gated SPECT and echocardiography for wall motion (91%, kappa = 0.68, p < 0.001) and thickening (90%, kappa = 0.62, p < 0.001). Correlation for global wall motion (r = 0.9S, p < 0.001) and thickening (r = 0.96, p < 0.001) scores between the two modalities was excellent. In 32 patients without previous myocardial infarction, there was excellent agreement for reversibility between stress sestamibi-gated SPECT and rest thallium-201/stress sestamibi (98%, kappa = 0.93, p < 0.01). However, in 26 patients with previous infarction, discordance between the two approaches was frequent, with 26% (20 of 78) of nonreversible defects by stress sestamibi-gated SPECT being reversible by rest thallium-201/stress sestamibi and 21% (23 of 112) of reversible defects by stress sestamibi-gated SPECT being nonreversible by rest thallium-201/stress sestamibi.Conclusions. Gated SPECT of stress-injected sestamibi correlates well with echocardiographic assessment of regional function and thus adds information to perfusion SPECT. In patients without previous myocardial infarction, a single-injection stress perfusion/rest function approach using sestamibi-gated SPECT can substitute for conventional stress/rest myocardial perfusion imaging, adding a rest perfusion study only if there are nonreversible defects or consideration of attenuation artifacts. In patients with previous myocardial infarction, the gated SPECT approach does not replace the need for a rest perfusion study.  相似文献   

10.
OBJECTIVE—To compare the relative accuracy of dobutamine stress echocardiography (DSE) and quantitative technetium-99m sestamibi single photon emission computed tomography (mibi SPECT) for detecting infarct related artery stenosis and multivessel disease early after acute myocardial infarction.
DESIGN—Prospective study.
SETTING—University hospital.
METHODS—75 patients underwent simultaneous DSE and mibi SPECT at (mean (SD)) 5 (2) days after a first acute myocardial infarct. Quantitative coronary angiography was performed in all patients after imaging studies.
RESULTS—Significant stenosis (> 50%) of the infarct related artery was detected in 69 patients. Residual ischaemia was identified by DSE in 55 patients and by quantitative mibi SPECT in 49. The sensitivity of DSE and mibi SPECT for detecting significant infarct related artery stenosis was 78% and 70%, respectively, with a specificity of 83% for both tests. The combination of DSE and mibi SPECT did not change the specificity (83%) but increased the sensitivity to 94%. Mibi SPECT was more sensitive than DSE for detecting mild stenosis (73% v 9%; p = 0.008). The sensitivity of DSE for detecting moderate or severe stenosis was greater than mibi SPECT (97% v 74%; p = 0.007). Wall motion abnormalities with DSE and transient perfusion defects with mibi SPECT outside the infarction zone were sensitive (80% v 67%; NS) and highly specific (95% v 93%; NS) for multivessel disease.
CONCLUSIONS—DSE and mibi SPECT have equivalent accuracy for detecting residual infarct related artery stenosis of  50% and multivessel disease early after acute myocardial infarction. DSE is more predictive of moderate or severe infarct related artery stenosis. Combined imaging only improves the detection of mild stenosis.


Keywords: myocardial infarction; dobutamine echocardiography; single photon emission computed tomography; SPECT; myocardial ischaemia  相似文献   

11.
OBJECTIVES: The purpose of this study was to test the ability of reinjection thallium-201 and rest technetium-99m sestamibi ECG (electrocardiographic)-gated SPECT (i.e., reinjection-g-SPECT [single-photon emission computed tomography] and MIBI-g-SPECT) to determine regional and global functional parameters. BACKGROUND: The ECG-gated perfusion SPECT was reported to provide accurate left ventricular ejection fraction (LVEF) using an automated algorithm. We hypothesized that other various functional data may be obtained using reinjection-g-SPECT and MIBI-g-SPECT. METHODS: Reinjection-g-SPECT, MIBI-g-SPECT, and three-dimensional magnetic resonance imaging (3DMRI) were conducted in 20 patients with coronary artery disease. Regional wall motion (RWM) and wall thickening (RWT) were analyzed using semiquantitative visual scoring by each g-SPECT and 3DMRI. The left ventricular end-systolic and end-diastolic volumes (EDV, ESV) and LVEF estimated by reinjection- and MIBI-g-SPECT were compared with the results of 3DMRI. RESULTS: A high degree of agreement in RWM and RWT assessment was observed between each g-SPECT and 3DMRI (kappa >.70, p < .001). The LVEF values by reinjection- and MIBI-g-SPECT correlated and agreed well with those by 3DMRI (reinjection: r = .92, SEE = 5.9%, SD of differences = 5.7%; sestamibi: r = .94, SEE = 4.4%, SD of differences = 5.1%). The same also pertained to EDV (reinjection: r = .85, SEE = 18.7 ml, SD of differences = 18.4 ml; sestamibi: r = .92, SEE = 13.1 ml, SD of differences = 13.0 ml) and ESV (reinjection: r = .94, SEE = 10.3 ml, SD of differences = 10.3 ml; sestamibi: r = .97, SEE = 6.7 ml [p < .05 vs. reinjection by F test], SD of differences = 6.6 ml [p < .05 vs. reinjection by F test]). CONCLUSIONS: Reinjection- and MIBI-g-SPECT provide clinically satisfactory various functional data. These functional data in combination with the perfusion information will improve diagnostic and prognostic accuracy without an increase in cost or the radiation dose to the patients.  相似文献   

12.
The ability of technetium (Tc)-99m sestamibi myocardial perfusion imaging at rest to evaluate myocardial infarction and first-pass ejection fraction was studied in a trial involving 18 institutions. Protocol I compared regional perfusion with occurrence of infarction by Q wave or by gated blood pool scan wall motion abnormality in 146 patients. Protocol II assessed first-pass right and left ventricular ejection fraction in 85 patients. In protocol I, Tc-99m sestamibi images were abnormal in 104 of 111 patients (94%) with both a Q wave and a gated scan wall motion abnormality and was normal in 23 of 25 patients (92%) in whom both were normal. Therefore, concordance existed in 105 (94%) patients. Of 115 patients with a Q wave, 107 (93%) had an abnormal Tc-99m sestamibi study. Of 115 patients with a gated scan wall motion abnormality, 108 (94%) had an abnormal Tc-99m sestamibi study. Tc-99m sestamibi imaging showed corresponding perfusion abnormalities in 81% of 69 anterior Q-wave infarcts, 73% of 55 inferior Q-wave infarcts and 88% of 8 posterior infarcts. Specificity in normal regions on electrocardiography and wall motion was 91, 100 and 100%, respectively, for anterior, inferior and posterior regions, respectively, between wall motion and perfusion. Of 17 myocardial segments per patient, there was concordance in 74% of patients. First pass Tc-99m sestamibi imaging of ejection fraction agreed well with conventional first-pass imaging for the right and left ventricle. It is concluded that Tc-99m sestamibi myocardial imaging at rest reliably diagnoses and localizes infarction and assesses ejection fraction by first-pass imaging.  相似文献   

13.
Thallium-201 myocardial imaging is of value in the early detection and evaluation of patients with suspected acute infarction. The extent of a thallium defect in an initial myocardial image may have important prognostic value. Tomographic imaging techniques hold promise for increased diagnostic sensitivity and more accurate quantitation of both infarcted and residual viable myocardium. Thallium imaging may have a special value in characterizing patients with cardiogenic shock and in detecting patients at risk for subsequent infarction or death or both, before hospital discharge.

Approximately 95 percent of patients with transmural or nontransmural myocardial infarction can be detected with technetium-99m pyrophos-phate myocardial imaging if the imaging is performed 24 to 72 hours after the onset of symptoms. Pyrophosphate imaging has been useful in localizing the site and determining the extent of acute myocardial infarction. The “doughnut” pattern is associated with a relatively large incidence of subsequent congestive heart failure and death. However, the clinical utility of this information is limited because it is usually not available when it is most needed, on admission to the coronary care unit. Pyrophosphate imaging may have an important role in the evaluation of patients during the early follow-up period after hospital discharge from an episode of acute infarction. The finding of a persistently positive pyrophosphate image suggests a poor prognosis and is associated with a relatively large incidence of subsequent myocardial infarction and death.  相似文献   


14.
15.
The incremental prognostic value of combined regional wall motion and perfusion over perfusion alone by gated single-photon emission computed tomographic myocardial perfusion scintigraphy has not been evaluated. Of the 402 consecutive patients who underwent stress single-photon emission computed tomographic myocardial perfusion scintigraphy for suspected myocardial ischemia, we identified 333 patients (217 men, mean age 63 +/- 10 years; exercise in 249 and dipyridamole adminstered to 84). Visual scoring of perfusion images and regional wall motion used 20 segments and a scale of 0 to 4. Resting and poststress left ventricular ejection fraction was automatically generated. On follow-up (median 13 months), 30 hard cardiac events (17 cardiac deaths, 13 nonfatal acute myocardial infarctions) and 66 total cardiac events (including hard events, 26 with unstable angina, and 10 who underwent late revascularization) occurred. After adjustment for prescan information, the best independent predictors of hard events were summed stress score for wall motion (Wald's chi-square 8.3, p <0.004) and several vascular territories with ischemia by perfusion/function (Wald's chi-square 6.2, p <0.01). The strongest predictors of all cardiac events were the number of ischemias (Wald's chi-square 32.1, p <0.0001) and the number of ischemic vascular territories by perfusion (Wald's chi-square 13.1, p <0.0001). Addition of function data to the combined model of perfusion data yielded an incremental value of 26% for predicting hard events but not for all events. In conclusion, the assessment of combined perfusion/function provides incremental prognostic information for further hard events with perfusion data alone; perfusion data best predict all cardiac events.  相似文献   

16.
Objectives. We prospectively compared myocardial uptake of thallium-201 (201Tl) at rest with rest technetium-99m (99mTc) sestamibi uptake in the same patients, using quantitative single-photon emission computed tomography (SPECT).

Background. Because of only slightly delayed redistribution, 99mTc-sestamibi uptake at rest may be less than 201Tl uptake, thereby underestimating the extent of viability.

Methods. Twenty patients (2.25 stenoses per patient) with a mean left ventricular ejection fraction of 33 ± 2% underwent early and 3-h delayed rest 201Tl SPECT, rest 99mTc-sestamibi SPECT and two-dimensional echocardiography.

Results. The 280 scan segments were classified as either a normal, mild reduction in viability, defined as delayed 201Tl uptake ≤75% and ≥5%, or a severe reduction in viability, defined as delayed 201Tl uptake <50%. Mild and severe defects were further classified as fixed or having rest 201Tl redistribution. Comparisons by patients were made using repeated measures analysis of variance and Dunnett's multiple comparisons test to compare 99mTc-sestamibi with initial rest 201Tl and delayed 201Tl uptake. Twenty patients had at least one mild fixed defect (95 total segments). The average percent uptake in these defects for initial 201Tl, delayed 201Tl and 99mTc-sestamibi was 62.5 ± 2.7%, 63.1 ± 7.1% and 67.3 ± 9.7%, respectively (p = NS). Twelve patients (27 segments) had mild redistribution defects on serial rest 201Tl imaging. The average percent uptake was 61.6 ± 5.2% for initial 201Tl, 67.0 ± 9.1% for delayed 201Tl and 67.7 ± 12.4% for 99mTc-sestamibi defects. Technetium-99m sestamibi uptake was not significantly different than that for delayed 201Tl but was significantly greater than initial 201Tl uptake. Seventeen patients (52 segments) had severe fixed 201Tl defects. The average percent uptake was 38.9 ± 7.3% for initial 201Tl, 38.3 ± 12.2% for delayed 201Tl and 42.7 ± 14.2% for 99mTc-sestamibi defects in these patients (p = NS). Ten patients (19 segments) had severe redistribution defects on rest 201Tl imaging. The average percent uptake was 37.0 ± 8.5% for initial 201Tl, 42.9 ± 8.6% for delayed 201Tl and 44.5 ± 11.3% for 99mTc-sestamibi defects. As was seen for mild 201Tl redistribution defects, 99mTc-sestamibi uptake was significantly higher than initial 201Tl uptake, but not significantly different than delayed 201Tl uptake in these severe defects.

Conclusions. Technetium-99m sestamibi uptake after injection at rest is comparable to 201Tl uptake after injection at rest in patients with severe coronary artery disease and left ventricular dysfunction, suggesting comparable worth for viability assessment.  相似文献   


17.
In order to compare the ability of dobutamine stress echocardiography (DSE) and exercise Thallium-201 SPECT to detect myocardial ischemia in patients with myocardial infarction (Ml) treated with thrombolysis, 43 prospectively selected patients with Ml treated with thrombolysis underwent within 1 month from Ml DSE, stress-redistribution-reinjection Thallium-201 SPECT and coronary angiography. The echocardiographic and scintigraphic images were analyzed for the presence of myocardial ischemia using a 11-segment left ventricular model. DSE and exercise Thallium-201 SPECT detected myocardial ischemia in the infarct zone in 72 and 72 (31/43) of patients and ischemia at a distance in 12 (5/43) and 19 (8/43) of patients with a concordance of 67 and 88 , respectively. A significant agreement between DSE and exercise Thallium SPECT was found in the evaluation of the extent of both myocardial necrosis and stress-induced myocardial ischemia. DSE and exercise Thallium SPECT showed similar sensitivity (79 vs 76), specificity (60 vs 60) and accuracy (77 vs 74) for detection of a critical stenosis of the infarct-related artery; there was also no significant difference between the tests in sensitivity, specificity and accuracy for detection of the multivessel disease.In conclusion, initially after thrombolyzed MI, DSE and exercise Thallium-201 SPECT detect myocardial ischemia in the infarct zone in a high proportion of patients and show a similar accuracy for the diagnosis of a critical stenosis of the infarct-related coronary artery and of the multivessel disease.  相似文献   

18.
The purpose of this study was to examine the rest thallium-201 perfusion pattern during angina-free periods in 40 patients with rest angina pectoris secondary to coronary artery disease (greater than or equal to 70% diameter narrowing). Seventeen patients had previous Q wave myocardial infarction. The perfusion defects were considered fixed or reversible, depending on the absence or presence of redistribution in the 4-hour delayed images. There were 40 perfusion defects (26 fixed and 14 reversible) in 27 patients whereas 13 patients had normal scans. Reversible perfusion defects were present in 10 patients (25%). Of the 26 fixed perfusion defects, 17 did not have corresponding Q waves. Occluded vessels (63%) had more perfusion defects than vessels with subtotal occlusion (30%) (p less than 0.01). The perfusion defect size was larger in patients with lower ejection fraction than in patients with higher ejection fraction. We conclude: (1) perfusion defects are common in patients with rest angina and are reversible in 25% of patients indicating reduced regional coronary blood flow; (2) the degree of stenosis affects the presence of perfusion defect; (3) fixed defects may be present without corresponding Q waves; and (4) global left ventricular function is related to the size of perfusion defects.  相似文献   

19.
BACKGROUND: The purpose of this study was to compare stress supine single photon emission computed tomography (SPECT) imaging with attenuation correction (AC) via computed tomography-based attenuation maps with stress prone SPECT imaging with regard to the rate of equivocal interpretation of rest/stress myocardial perfusion imaging. METHODS AND RESULTS: Interpretations for 324 consecutive patients referred for rest/stress myocardial perfusion imaging were performed by use of the following sets of poststress SPECT images: supine with no AC (NC), supine NC/AC, supine NC/prone, and all images. The number of equivocal studies decreased with additional imaging: supine NC, 40%; supine NC/prone, 18%; supine NC/AC, 11%; and all images, 8%. The supine NC/AC sets of images reduced the number of defects to a greater extent than the supine NC/prone images for all patients (P = .01), men (P = .002), and women (P = .425). For the inferior (but not the anterior) wall, the percent decrease in defects with supine NC/AC images was lower as compared with supine NC/prone images. CONCLUSION: Interpretation with all images resulted in the fewest equivocal studies. The supine NC/AC images reduced the number of equivocal studies to a greater extent than the supine NC/prone images. AC and prone imaging were more helpful in men than women and were more helpful to resolve inferior than anterior wall defects. Adding prone imaging to supine imaging without and with AC does not significantly alter the number of equivocal interpretations.  相似文献   

20.
Left ventricular (LV) and right ventricular (RV) involvement in sarcoidosis must be firmly confirmed to determine patients' prognosis. We examined whether myocardial perfusion images using technetium-99m single photon emission computed tomography (SPECT) have a diagnostic benefit in the evaluation of biventricular involvement. Sixteen patients with sarcoidosis, aged 21-78 (54 +/- 12) years old, 5 males and 11 females, complicated with cardiac disease (cardiac sarcoidosis, n = 6) including tachyarrhythmias of ventricular origin (n = 5), atrioventricular block (n = 4), and congestive heart failure (NYHA > or = II, n = 1), were enrolled in this study. Myocardial SPECT using technetium-99m sestamibi or tetrofosmin was performed and semiquantitatively scored for comparison with 25 control subjects. Perfusion abnormalities were more frequently recognized in sarcoidosis (LV 5/16, 31% and RV 14/16, 88% vs. LV 0/25, 0% and RV 8/25, 32% in controls). LV involvement had a close correlation with atrioventricular block and with congestive heart failure, and multiple sites of RV involvement correlated with ventricular tachyarrhythmia of RV origin. Total number of defect segments were highest in cardiac sarcoidosis (18/30, 60% vs. 19/60, 32% in noncardiac sarcoidosis, and 11/150, 7% in controls, p = 0.0001), and semiquantitatively evaluated total LV and RV scores (ranging from 0 to 18) were higher than those of controls (15.1 +/- 1.8 vs. 11.4 +/- 3.0 in noncardiac sarcoidosis, and 9.0 +/- 5.0 in cardiac sarcoidosis) and exhibited a significant positive linear correlation with the RV ejection fraction (y = 19.8 + 1.83x, r = 0.786, p = 0.001). Biventricular SPECT using technetium-99m is clinically useful for the noninvasive evaluation of both ventricular involvements in sarcoidosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号