首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
目的 探讨Sysmex XT-1800i血细胞分析仪对形态异常细胞提示功能的可信度.方法 对Sysmex XT-1800i提示异常的163份标本进行显微镜复检并对比分析.结果 Sysmex XT-1800i提示异常的163份标本经镜检有异常形态细胞者仅占42.8%.结论 血细胞分析仪不能完全代替显微镜手工分类,当仪器提示有异常形态细胞时必须作显微镜复检,以防止误诊、漏诊病例的发生.  相似文献   

2.
目的评估Sysmex XT1800i全自动血液分析仪对异常血细胞报警的可信度。方法选择Sysmex XT1800i异常血细胞报警的标本296例,无异常报警的标本180例,进行手工推片瑞氏染色镜检,观察血涂片红细胞、白细胞和血小板形态,与Sysmex XT1800i异常报警进行比较。结果 Sysmex XT1800i对异常血细胞报警灵敏度100.0%,特异性58.4%,阳性预测值56.7%,阴性预测值100.0%,对血小板的聚集和异型淋巴细胞警告功能较差。结论 Sysmex XT1800i全自动血液分析仪能够有效地筛选出真正异常的标本,同时应结合仪器性能制定复检规则,使工作人员更有效对真阳性标本进行复检。  相似文献   

3.
目的 探讨Sysmex XT-2000i血细胞分析仪计数白细胞报警(WBC IP MESSAGE)的准确性.方法使用Sysmex XT-2000i血细胞分析仪随机检测945例非血液科患者的外周血标本,同时做血涂片显微镜检查,包括分类计数白细胞并观察其细胞形态,按照涂片复检阳性判断标准判定后,与提示IP警示的145例标本...  相似文献   

4.
XE-2100血细胞分析仪异常细胞报警信息的可信性分析   总被引:1,自引:0,他引:1  
目的 探讨Sysmex XE-2100血细胞分析仪在白细胞分类时对异常细胞报警信息的可信性。方法通过对200例XE-2100血细胞分析仪报警有原始细胞(Blasts)、未成熟粒细胞(Imm Gran)、异形淋巴细胞(Atypical Ly)、有核红细胞(NRBC)的全血标本作手工血涂片,经瑞特-姬姆萨染色后用显微镜目测法分类(金标准)比较。以无异常报警的200例标本为对照组。分析仪器对异常细胞报警的可信性。结果 仪器Blasts、Imm Gran、Atypical Ly和NRBC报警的阳性预测值分别为70.3%、63.7%、62.0%和60.0%。结论 XE-2100血细胞分析仪对异常细胞的检出性能较高,检测结果有异常细胞报警的标本均应该进行手工涂片染色、显微镜复检。  相似文献   

5.
目的 以人工显微镜白细胞分类法为参考方法,评价Coulter LH 750血液分析仪;Sysmex XS800i;Sysmex XT2000全自动血细胞分析仪检测健康体检者白细胞分类结果的准确性。方法 用人工显微镜和3种类型的血细胞分析仪分别对50例健康体检者血液标本进行白细胞分类,比较这3种仪器与人工镜检对白细胞分类结果的相关性。结果 此3种类型血细胞分析仪与人工显微镜分类所得中性粒细胞、淋巴细胞及嗜酸细胞的分类结果进行相关分析,相关性较好(r>0.91);而单核细胞及嗜碱细胞的分类结果进行相关分析,相关性相对较差(r<0.68);而参照Rumke表所得3种仪器与人工显微镜分类结果的符合率均大于或等于90%。结论 这3种类型的全自动血细胞分析仪白细胞分类的结果与人工镜检法的结果具有良好的可比性。  相似文献   

6.
目的制定适合本实验室的Sysmex XT-1800i全自动血液分析仪(简称XT-1800i分析仪)复检规则。方法采用XT-1800i分析仪检测1 841份标本的同时制备血涂片标本,手工分类白细胞并观察红细胞、白细胞及血小板形态。按照初步复检规则和涂片镜检标准进行评估,结合实际情况修正初步复检规则后制定适合本实验室的XT-1800i分析仪复检规则。结果以初步复检规则和涂片镜检标准进行评估,真阳性率为28.9%、假阳性率为11.9%、真阴性率为57.1%、假阴性率为2.0%、涂片复检率为40.9%。为将涂片复检率降至30%以下,修正初步复检规则,形成XT-1800i分析仪复检规则,并结合涂片镜检标准重新进行评估,真阳性率为14.8%、假阳性率为9.4%、真阴性率为72.6%、假阴性率为3.2%、涂片复检率为24.2%。验证实验表明有病理意义的白血病细胞无漏检。结论通过制定适合本实验室的XT-1800i分析仪复检规则,提高了工作效率,保证了检验结果的质量,可有效避免漏检病理标本及发出错误报告。  相似文献   

7.
目的对Sysmex XE-2100血细胞分析仪检测儿童末梢血异常细胞报警提示功能进行评价。方法采用Sysmex XE-2100血细胞分析仪对804例儿童末梢血标本进行检测,同时进行血涂片检查血细胞形态,通过统计比较,评价该血细胞分析仪异常细胞报警提示功能的可靠性能。结果 Sysmex XE-2100血细胞分析仪对儿童末梢血异常细胞报警提示功能的灵敏度为100%,特异性为69.80%,阳性预测值为54.10%,阴性预测值为100%,仪器检出准确度为77.74%,假阳性率为45.90%。结论 Sysmex XE-2100血细胞分析仪检测儿童末梢血异常细胞报警提示系统的功能良好,灵敏度高,可降低涂片复检次数,提高临床工作效率和检验质量,但同时也存在较高的假阳性率,需进一步对其进行血涂片镜检加以确认。  相似文献   

8.
XS-800i血细胞分析仪异常报警在儿科血液分析中的评价   总被引:2,自引:2,他引:0  
目的评价XS-800i在儿科血液分析中白细胞分类异常报警的价值。方法采用显微镜人工分类与仪器分类对比。结果XS-800i五分类血细胞分析仪白细胞分类异常报警的敏感度为96.0%,特异性为68.5%,阳性预测值为83.3%,左移83.3%,原始细胞77.8%,异型淋巴细胞74.9%,有核红细胞73.9%,异淋69.2%。结论各实验室应根据显微镜人工分类与仪器分类对比结果制定出各自的复检标准,提高白细胞分类结果的准确性。  相似文献   

9.
目的 探讨当血细胞分析仪检测时,出现异常结果,需要做显微镜复查的必要性以及在何种情况下进行显微镜复查,以保证检验工作的质量和效率.方法 回顾性分析解放军第313医院采用XT1800i型全自动血细胞分析仪检测的8 043份标本,对其中存在异常结果信息的标本进行手工推片、染色、显微镜复查血片进行综合分析.结果 XT1800i型全自动血细胞分析仪检测敏感度为100.0%,特异度为68.9%,阳性预测值89.4%,阴性预测值100.0%,准确度74.8%.显微镜检测随报警信息的不同,阳性率有不同程度的增高.结论 XT1800i型全自动血细胞分析仪参数多、灵敏度高,是一种大批量全血标本血细胞进行快速而有效的筛查的血液分析仪,对于有异常的标本仪器能够给出比较准确的分析结果.  相似文献   

10.
目的探讨全自动五分类Sysmex XE2100血液分析仪应用于门诊患者的筛查效果。方法对1 000例门诊患者的血液标本同时用Sysmex XE2100血液分析仪分析及显微镜复检,评价其报警系统的性能,并对出现解释性(IP)信息的标本进行分析,同时调查患者就诊科室的分布情况。结果 1 000例门诊患者血标本出现IP信息的比例为12.0%,白细胞分类报警系统的特异性为98.9%,灵敏度为100.0%,阳性预测值85.5%,阴性预测值100.0%,总有效率99.0%。红细胞假阳性率9.0%,以红细胞碎片及缺铁性贫血多见,血小板假阳性率16.0%,以聚集多见。出现IP信息的标本主要来源于急诊科、妇产科、呼吸科、体检中心、儿科。结论五分类血液分析仪在门诊进行血常规分析,覆盖面广,可以起到很好的筛检作用,可提高工作质量和效率。  相似文献   

11.
野战运输对红细胞保存的影响   总被引:3,自引:0,他引:3  
为了研究野战运输条件对几种血液成份的影响,为战时伤病员救治的血液保障提供依据,将红细胞悬液、少白细胞的红细胞悬液和洗涤红细胞经过模拟野战公路(三级公路)运输(震荡)4小时,然后在4℃条件下继续保存15天;取震荡前、后及保存15天的3个时间点的血样,分别进行上清游离血红蛋白、血常规和血生化分析。结果表明:红细胞悬液和少白细胞的红细胞悬液组游离血红蛋白、乳酸脱氢酶和钾离子浓度在震荡前、后及保存15天后的改变没有明显差异,而洗涤红细胞在震荡后上述三项指标显著增加,继续保存15天后,进一步增高。3个组中其它一些血液学指标没有明显的改变。结论:野战运输条件下(三级公路),采取合理的保温和减震措施后,运输4小时内红细胞悬液和少白细胞的红细胞悬液仍然可以继续保存15天并应用于临床,而洗涤红细胞则不能。  相似文献   

12.

Objective

The goal of this study was to estimate the cost of production of 1 unit of blood from a National Health Service perspective in Greece.

Methods

In agreement with guidelines, the cost of blood production in this study accounted only for the resources expended for collection, processing, laboratory testing, and storage. Hence, the costs associated with donor recruitment, pretransfusion preparation, transfusion administration, follow-up management of adverse events, and other long-term relevant costs were not taken into consideration. The indirect cost of blood donations for donors (productivity loss) was also considered. A questionnaire was used to collect data regarding personnel time, annual blood quantities collected, percentage of wastage, utilization of consumables, institutional overhead, information technology expenditure, medical equipment utilized, nuclear acid tests, and other factors. Data gathered by 53 hospitals across the country were assessed. A model was constructed with economic data collected by the National School of Public Health and the Ministry of Health. All data refer to the year 2013.

Results

The weighted mean direct cost of producing 1 unit of blood was estimated at €131.49 (SD, €22.12; minimum/maximum, €94.96–€239.20). The mean total indirect cost was estimated at €34 per unit of blood. The cost distribution was positively skewed (skewness, 1.642 [0.327]). The major cost component was the cost of personnel, accounting for 32.5% of total costs, and the average of blood unit wastage was estimated at 4.90%. There were no differences between the cost of producing 1 unit of blood in Athens compared with the rest of the country (Mann-Whitney test, P = 0.341).

Conclusions

This study suggests that the cost of producing 1 unit of blood is not insignificant. These figures need to be complemented with those concerning the cost of transfusion to have a complete picture of producing and using 1 unit of blood locally.  相似文献   

13.
探讨受血为婴幼儿或老弱患在采取血样困难时取少量抗凝血做交叉配血试验的可行性。应用ABO同型血做交叉配血试验76次;将ABO异型血分为A和B,A和O,A和AB,B和O,B和AB,O和AB6组,每组配血3次,共配血18次。ABO同型配血,结果检出1例不完全抗体,76次配血,没有发生输血反应;ABO异型配血,出现凝集现象。结果提示,取患少量抗凝血做交叉配血是可行的。  相似文献   

14.
目的 探讨防止血液流变标本凝血的最佳方法.方法 将577例体检者分为两组,常规组分次将标本摇匀;推动组使血液流变标本在操作台面上滚动,一次完成防凝血操作.比较两种方法进行防凝血操作护士手臂感觉评分、静脉血标本采集时间、血液标本凝血率.结果 推动方法手臂感觉评分、采血时间、凝血率均低于常规方法,差异具有统计学意义(P<0...  相似文献   

15.
目的探讨民航飞行员人群中高尿酸发病率及其与血脂、血糖和血压之间的相互关系及其临床意义。方法收集2009年12月至2010年12月1 100名民航飞行员的体检资料,用统计学方法分析其高血尿酸患病率特点及其与及其与血脂、血糖和血压之间的相互关系。结果在各年龄组中,高尿酸血症的分布呈现先高后低的规律,其峰值出现在36~40岁组占39.05%,且高尿酸组的高血脂患病率为37.12%、高血糖患病率为25.00%及高血压患病率为29.92%,均明显高于正常血尿酸组的13.24%、15.01%、16.08%,差异有统计学意义(P<0.01)。结论民航飞行员年龄在36~40岁时,其血尿酸的水平最高,且高血尿酸与高血脂、高血糖及高血压呈正相关。应该注意防护。  相似文献   

16.
目的比较白血病患者化疗后骨髓抑制期末梢血与静脉血中白细胞(WBC)、血红蛋白(HB)、血小板(PLT)检测结果有无差别。方法采集2012年4月2013年4月我院血液科层流病房96名化疗后骨髓抑制期患者的末梢血和静脉血,用XT-2000i全血细胞分析仪测定白细胞(WBC)、血红蛋白(HB)、血小板(PLT),统计分析两种检测手段的差异。结果末梢血的白细胞(WBC)检测结果为:1.106±0.684×10^9/L,静脉血检测结果为:0.918±0.780×10^9/L,末梢血白细胞检测值高于静脉血结果,两者具有统计学意义(P〈0.05);末梢血中血红蛋白(HB)、血小板(PLT)检测结果分别为:69.875±15.437g/L,70.646±20.737×10^9/L,静脉血检测结果分别为:70.177±15.225g/L,70.583±20.625×10^9/L,两组血标本检测结果差异无统计学意义(P〉0.05)。结论为准确的判断白血病患者化疗后骨髓抑制的程度,血常规检测应以静脉血为佳,而不能采用末梢血检测以代替。  相似文献   

17.
桑奕雯 《国际检验医学杂志》2014,(21):2934-2936,2938
目的探讨血象检查在白血病诊断中的参考价值。方法选取1979~2013年间常见白血病1 480例,参照2008年世界卫生组织(WHO)形态学标准对其进行重新阅片诊断,随机双盲法比较各常见白血病检出情况及其血常规主要参数特征。另选取同时进行血涂片与骨髓涂片检查的急性白血病136例,采用双盲法比较血涂片与骨髓涂片中白血病细胞数,研究血涂片形态学特征。随机选取血涂片与骨髓涂片白血病细胞数均超过20%的59例急性白血病,采用双盲法进行单一的血涂片或骨髓涂片镜检,比较两者诊断符合率。结果不伴成熟型急性髓细胞白血病(AML)、伴成熟型AML、急性单核细胞白血病与慢性淋巴细胞白血病(CLL)的白细胞计数(WBC)以(>10~50)×109/L为主,急性早幼粒细胞白血病(APL)与急性红白血病(AEL)的WBC以小于或等于4×109/L为主,慢性粒细胞白血病(CGL)的WBC以大于100×109/L为主。镜检发现几乎所有患者外周血涂片中白血病细胞形态较骨髓涂片中成熟,当血涂片与骨髓涂片白血病细胞数均超过20%时,单一血涂片与单一骨髓涂片镜检诊断急性白血病的符合率差异无统计学意义(P>0.05)。结论血常规主要参数对白血病的诊断具有较好提示作用,当血涂片中白血病细胞数较高时,单一血涂片检查对常见白血病诊断亦具有较高符合率。  相似文献   

18.
目的评价Sysmex XE-2100血细胞分析仪计数外周血有核红细胞(NRBC)的性能。方法选择门诊与住院患者乙二胺四乙酸二钾抗凝血标本,采用Sysmex XE-2100血细胞分析仪与手工显微镜方法计数NRBC,并对结果进行比较。结果血细胞分析仪与手工显微镜方法之间相关性良好,相关系数为0.938 4;58份标本仪器法NRBC在0.00%~0.99%标本中14份(24.1%)手工法NRBC结果为0.00%。24份仪器法NRBC结果为0.00%的标本中22份(91.2%)手工法小于或等于1.00%;仪器法重复性明显好于手工法,NRBC平均CV为8.0%。结论 Sysmex XE-2100血细胞分析仪与手工显微镜法之间相关性较好;仪器法重复性明显好于手工法;尽管出现少量仪器法与镜检法不一致结果,但均伴有其他白细胞和(或)血小板异常报警提示,也进行了显微镜复核。  相似文献   

19.
目的 分析重庆市血液中心血液采供情况,为保障临床合理用血提供可靠的科学依据.方法 对重庆市血液中心2010~2015年献血人数、献血量、献血人群年龄分布、固定献血者献血比例及临床用血情况进行统计分析.结果 除单采血小板献血人数和献血量有所增长外,献血量、献血人次分别由2010年的202 002 U、114 388人次下降到2015年的178 997 U、104 844人次.临床用血受采集量下降的影响也呈逐年下滑的趋势.35岁以下献血者占70.0%以上,固定献血者占30.7%.结论 从2011年开始采供血量逐年下降,主要是因为献血人数及献血量逐年降低,2015年有反弹趋势;35岁以下的年轻人是无偿献血的主要人群,固定献血者比例偏低.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏