首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
9-[(3-[18F]Fluoro-1-hydroxy-2-propoxy)methyl]guanine ([18F]FHPG, 2) has been synthesized by nucleophilic substitution of N(2)-(p-anisyldiphenylmethyl)-9-[[1-(p-anisyldiphenylmethoxy)-3-toluenesulfonyloxy-2-propoxy]methyl]guanine (1) with potassium [18F]fluoride/Kryptofix 2.2.2 followed by deprotection with 1 N HCl and purification with different methods in variable yields. When both the nucleophilic substitution and deprotection were carried out at 90 degrees C and the product was purified by HPLC (method A), the yield of compound 2 was 5-10% and the synthesis time was 90 min from EOB. However, if both the nucleophilic substitution and deprotection were carried out at 120 degrees C and the product was purified by HPLC, the yield of compound 2 decreased to 2%. When compound 2 was synthesized at 90 degrees C and purified by Silica Sep-Pak (method B), the yield increased to 10-15% and the synthesis time was 60 min from EOB. Similarly, 9-(4-[18F]fluoro-3-hydroxymethylbutyl)guanine ([18F]FHBG, 4) was synthesized with method A and method B in 9% and 10-15% yield, respectively, in a synthesis time of 90 and 60 min, respectively, from EOB. Compound 2 was relatively unstable in acidic medium at 120 degrees C while compound 4 was stable under the same condition. Both compound 2 and compound 4 had low lipid/water partition coefficient (0.126 +/- 0.022, n=5 and 0.165 +/- 0.023, n=5, respectively). Although it contains non-radioactive ganciclovir ( approximately 5-30 microg) as a chemical by-product, compound 2 synthesized by method B has a similar uptake in 9L glioma cells as that synthesized by method A, and is a potential tracer for imaging herpes simplex virus thymidine kinase gene expression in tumors using PET. Similarly, compound 4 synthesized by method B contains approximately 10-25 microg of penciclovir as a chemical by-product. Thus, the simplified one pot synthesis (method B) is a useful method for synthesizing both compound 2 and compound 4 in good yield for routine clinical use, and the method is readily amenable for automation.  相似文献   

2.
The aim of this study was to develop an automated synthesis of 9-(4-[(18)F]-fluoro-3-hydroxymethylbutyl)guanine ([(18)F]FHBG) and 9-[(3-[(18)F]fluoro-1-hydroxy-2-propoxy)methyl]guanine ([(18)F]FHPG) using a Scanditronix Anatech RB III robotic system. [(18)F]HF was produced via (18)O(p, n)(18)F using a Scanditronix MC17F cyclotron. On average, a typical run produced [(18)F]FHBG and [(18)F]FHPG with an uncorrected radiochemical yield of 19% and 16%, respectively, at end of synthesis (EOS) from irradiation of 95% enriched [(18)O]water. The total synthesis time was 80 min. The retention time of [(18)F]FHBG and [(18)F]FHPG (the radio-peak) was 3.9 and 4.0 min, respectively, which was consistent with the [(19)F]FHBG and [(19)F]FHPG ultraviolet peak. The radiochemical purity was greater than 97%. A robotic, automated method for [(18)F]FHBG and [(18)F]FHPG radiosynthesis is therefore feasible. The radiation burden for the operator can be reduced as much as possible. Sufficient radioactivities of [(18)F]FHBG and [(18)F]FHPG could be obtained for non-invasive monitoring the expression of transfected gene in vivo with positron emission tomography (PET).  相似文献   

3.
We have developed synthesis methods for 9-(4-[18F]fluoro-3-hydroxymethylbutyl)guanine ([18F]FHBG) using two commercial automatic chemistry modules, Tracerlab MX and Explora RN, and compared radiochemical yields. Synthesis conditions and sequence programs were modified for two modules because both these modules have different mechanical structures, including heater type, vacuum system, reactor, and tubing size. Synthesis using the Tracerlab MX module showed a 21.0±3.8% yield of radiochemical, which was 98±0.9% pure; the total preparation time was 63.0±5.0 min including an HPLC purification step. In contrast, synthesis using the Explora RN module showed a 32.0±1.2% yield of radiochemical, which was 99.0±0.6% pure; the total preparation time was 38±2 min, using different HPLC purification conditions and without the HPLC solvent evaporation step.  相似文献   

4.
INTRODUCTION: 2-Amino-6-[(18)F]fluoro-9-(4-hydroxy-3-hydroxy-methylbutyl) purine (6-[(18)F]FPCV) was prepared via a one-step nucleophilic substitution and evaluated as a novel probe for imaging the expression of herpes simplex virus type 1 thymidine kinase (HSV1-tk) reporter gene. METHODS: Log P of 6-[(18)F]FPCV was calculated in octanol/phosphate-buffered saline (PBS). Stability studies were performed in PBS and bovine serum albumin (BSA). Cell uptake was performed at various time points in wild-type cells and transduced cells. For in vivo studies, tumors were grown in nude mice by inoculation with C6 cells, wild type and tk positive. The radiotracer was intravenously injected to animals, and micro-PET imaging was performed. Biodistribution of 6-[(18)F]FPCV was performed on another group of animals at different time points. RESULTS: Log P of 6-[(18)F]FPCV was -0.517. 6-[(18)F]FPCV was fairly stable in PBS and BSA at 6 h. The tracer uptake in C6-tk cells was 5.5-18.8 times higher than that in wild-type cells. The plasma half-life of 6-[(18)F]FPCV was as follows: alpha t(1/2)=1.2 min and beta t(1/2)=73.7 min. The average ratio of tumor uptake between the transduced tumor and the wild-type tumor was 1.69 at 15 min. CONCLUSION: Biological evaluation showed that 6-[(18)F]FPCV is a potential probe for imaging HSV1-tk gene expression. However, its in vivo defluorination may limit its application in PET imaging of gene expression.  相似文献   

5.
6.
Preparation of 9-[(3-18F-fluoro-1-hydroxy-2-propoxy)methyl]-guanine ([18F]-FHPG) for clinical use, and its evaluation as a positron emission tomography (PET) imaging agent for gene incorporation and expression in tumors are reported. In vitro studies in human colon cancer cells, HT-29, transduced with the retroviral vector G1Tk1SvNa and nontransduced (wild type) showed 4, 8, 12, and 15 times higher uptake of the probe in 1, 3, 5, and 7 h, respectively, in transduced cells compared with the controls. In vivo studies in tumor-bearing nude mice demonstrated that the tumor uptake of the radiotracer is three and six-fold higher in 2 and 5 h, respectively, in transduced cells compared with the control cells. These results suggest that [18F]-FHPG is a potential in vivo PET imaging agent for monitoring gene incorporation and expression in gene therapy of cancer.  相似文献   

7.
Both ABT-594 ((R)-2-chloro-5-(2-azetidinylmethoxy)pyridine) and A-85380 (3-[2(S)-2-azetidinylmethoxy]pyridine), novel nicotinic agonists that possess potent non-opioid analgesic properties, have high affinity for neuronal nicotinic acetylcholine receptors (nAChR) but do not elicit the pronounced toxicity of epibatidine. 6-[(18)F]Fluoro-3-(2(S)-azetidinylmethoxy)pyridine (6-[(18)F]fluoro-A-85380), a F-18 labeled analogue of these two compounds, is therefore a promising radioligand for positron emission tomography (PET) studies in humans. The use of trimethylammonium as a leaving group in nucleophilic aromatic substitution reactions has proven to be a versatile and efficient strategy, and offers several advantages over other leaving groups. Here, we report the synthetic strategy for the preparation of a precursor, as a trimethylammonium iodide salt, and its use in the radiosynthesis to 6-[(18)F]fluoro-A-85380. Preliminary compartative PET studies of 6-[(18)F]fluoro-A-85380 and 2-[(18)F]fluoro-A-85380 were carried out in baboon to examine their suitability as tracers for studying nAChR system.  相似文献   

8.
PurposeThe purpose of this prospective study was to clarify the value of FLT PET and FET PET for the noninvasive grading and prognosis of newly diagnosed gliomas.Materials and methodsTwenty patients with newly diagnosed gliomas were investigated with FLT and FET PET before surgery. FLT and FET uptakes were assessed by the maximum standardized uptake (SUVmax) of tumor, and the ratio to uptake in the normal brain parenchyma (TNR). All tumors were graded by WHO system.ResultsFLT PET detected all 17 high-grade gliomas (HGG) and did not detect all 3 low-grade gliomas (LGG). FET PET detected all 20 HGG and LGG regardless of grading. The average FLT SUVmax in HGG and LGG was 1.51 ± 0.72 and 0.30 ± 0.07, and the average FLT TNR in HGG and LGG was 5.52 ± 3.09 and 1.12 ± 0.14, respectively. The differences of FLT SUVmax and TNR between HGG and LGG were statistically significant (p = 0.0069, p = 0.0070). The average FET SUVmax in HGG and LGG was 2.68 ± 0.86 and 1.36 ± 0.15, and the average FET TNR in HGG and LGG was 2.31 ± 0.73 and 1.27 ± 0.12, respectively. The differences of FET SUVmax and TNR between HGG and LGG were statistically significant (p = 0.0129, p = 0.0095).ConclusionsFET PET has higher sensitivity in detection of gliomas rather than FLT PET, but it seems that FLT PET is better than FET PET for noninvasive grading and predicting prognosis of newly diagnosed gliomas, considering high contrast of FLT and overlap of FET uptakes between HGG and LGG.  相似文献   

9.
INTRODUCTION: Sigma-1 receptors are expressed throughout the mammalian central nervous system (CNS) and are implicated in several psychiatric disorders, including schizophrenia and depression. We have recently evaluated the high-affinity (K(D)=0.5+/-0.2 nM, log P=2.9) sigma-1 receptor radiotracer [(18)F]1-(3-fluoropropyl)-4-(4-cyanophenoxymethyl)piperidine, [(18)F]FPS, in humans. In contrast to appropriate kinetics exhibited in baboon brain, in the human CNS, [(18)F]FPS does not reach pseudoequilibrium by 4 h, supporting the development of a lower-affinity tracer [Waterhouse RN, Nobler MS, Chang RC, Zhou Y, Morales O, Kuwabara H, et al. First evaluation of the sigma-1 receptor radioligand [(18)F]1-3-fluoropropyl-4-((4-cyanophenoxy)-methyl)piperidine ([(18)F]FPS) in healthy humans. Neuroreceptor Mapping 2004, July 15-18th, Vancouver, BC Canada 2004]. We describe herein the in vivo evaluation in rats of [(18)F]1-(2-fluoroethyl)-4-[(4-cyanophenoxy)methyl]piperidine ([(18)F]SFE) (K(D)=5 nM, log P=2.4), a structurally similar, lower-affinity sigma-1 receptor radioligand. METHODS: [(18)F]SFE was synthesized (n=4) as previously described in good yield (54+/-6% EOB), high specific activity (2.1+/-0.6 Ci/micromol EOS) and radiochemical purity (98+/-1%) and evaluated in awake adult male rats. RESULTS: Similar to [(18)F]FPS, regional brain radioactivity concentrations [percentage of injected dose per gram of tissue (%ID/g), 15 min] for [(18)F]SFE were highest in occipital cortex (1.86+/-0.06 %ID/g) and frontal cortex (1.76+/-0.38 %ID/g), and lowest in the hippocampus (1.01+/-0.02%ID/g). Unlike [(18)F]FPS, [(18)F]SFE cleared from the brain with approximately 40% reduction in peak activity over a 90-min period. Metabolite analysis (1 h) revealed that [(18)F]SFE was largely intact in the brain. Blocking studies showed a large degree (>80%) of saturable binding for [(18)F]SFE in discrete brain regions. CONCLUSIONS: We conclude that [(18)F]SFE exhibits excellent characteristics in vivo and may provide a superior PET radiotracer for human studies due to its faster CNS clearance compared to [(18)F]FPS.  相似文献   

10.
16 alpha-[(18)F]fluoro-17beta-estradiol ([(18)F]FES) is a radiotracer for imaging estrogen receptors by positron emission tomography. We developed a clinically applicable automatic preparation system for [(18)F]FES by modifying a cassette-type [(18)F]fluorodeoxyglucose synthesizer. Two milligrams of 3-O-methoxymethyl-16,17-O-sulfuryl-16-epiestriol in acetonitrile was heated at 105 degrees C for 10 min with dried [(18)F]fluoride. The resultant solution was evaporated and hydrolyzed with 0.2 N HCl in 90% acetonitrile/water at 95 degrees C for 10 min under pressurized condition. The neutralization was carried out with 2.8% NaHCO(3), and then the high-performance liquid chromatography (HPLC) purification was performed. The desired radioactive fraction was collected and the solvent was replaced by 10 ml of saline, and then passed through a 0.22-microm filter into a pyrogen-free vial as the final product. The HPLC purification data demonstrated that [(18)F]FES was synthesized with a yield of 76.4+/-1.9% (n=5). The yield as the final product for clinical use was 42.4+/-3.2% (n=5, decay corrected). The total preparation time was 88.2+/-6.4 min, including the HPLC purification and the solvent replacement process. The radiochemical purity of the final product was >99%, and the specific activity was more than 111 GBq/micromol. The final product was stable for more than 6 h in saline containing sodium ascorbate. This new preparation system enables us to produce [(18)F]FES safe for clinical use with high and reproducible yield.  相似文献   

11.
INTRODUCTION: [(18)F]-Labeled analogues of thymidine have demonstrated efficacy for PET imaging of cellular proliferation. We have synthesized two [(18)F]-labeled N(3)-substituted thymidine analogues, N(3)-[(18)F]fluoroethyl thymidine (N(3)-[(18)F]-FET) and N(3)-[(18)F]fluoropropyl thymidine (N(3)-[(18)F]-FPrT), and performed preliminary PET imaging studies in tumor-bearing mice. METHODS: Thymidine was converted to its 3',5'-O-bis-tetrahydropyranyl ether, which was then converted to the N(3)-ethyl and propyl-substituted mesylate precursors. Reactions of these mesylate precursors with n-Bu(4)N[(18)F] or K[(18)F]/kryptofix followed by acid hydrolysis and HPLC purification yielded N(3)-[(18)F]-FET and N(3)-[(18)F]-FPrT, respectively. Subcutaneous (sc) xenografts of H441 human non-small cell lung cancer were established in two groups of mice (each n=6). Micro-PET images of the tumor-bearing animals were acquired after intravenous injection of N(3)-[(18)F]-FET or N(3)-[(18)F]-FPrT (3700 KBq/animal). RESULTS: The radiochemical yields were 2-12% (d.c.) for N(3)-[(18)F]-FET and 30-38% (d.c.) for N(3)-[(18)F]-FPrT. Radiochemical purity was >99% and calculated specific activity was >74 GBq/mumol at the end of synthesis. The accumulation of N(3)-[(18)F]-FET and N(3)-[(18)F]-FPrT in the tumor tissue at 2 h postinjection was 1.81+/-0.78 and 2.95+/-1.14 percent injected dose per gram (%ID/g), respectively; tumor/muscle ratios were 5.57+/-0.82 and 7.69+/-2.18, respectively; the unidirectional influx rates (K(i)) were 0.013 and 0.018 ml/g per minute, respectively. CONCLUSION: Two novel [(18)F]- N(3)-substituted thymidine analogues have been synthesized in good yields, high purity and high specific activity. Preliminary in vivo studies demonstrated the efficacy of these [(18)F]- N(3)-substituted thymidine analogues for PET imaging of tumors.  相似文献   

12.
The liver is an important site of fat oxidation. Abnormalities of hepatic mitochondrial fatty acid oxidation (HMFAO) are associated with obesity, type II diabetes, alcoholic hepatitis, and nonalcoholic steatohepatitis. Noninvasive assessment of HMFAO by PET has been impeded by the lack of a specific radiotracer. METHODS: No-carrier-added 15-[18F]fluoro-3-oxa-pentadecanoate (FOP) was synthesized and evaluated in living rats and isolated rat livers. RESULTS: FOP showed high uptake and slow clearance of radioactivity from livers in living rats. Inhibition of HMFAO by pretreatment of fasting rats with the carnitine palmitoyltransferase-I (CPT-I) inhibitor reduced the liver-to-blood ratio by 64%. In isolated rat livers, perfused in normoxic (95% O2) and hypoxic (15% O2) conditions with glucose (5 mmol/L) and palmitate (0.15 mmol/L), the externally measured kinetics of FOP showed reversible binding in tissue. The kinetics were adequately fit by a catenary 2-compartment model for estimation of tracer distribution volumes (DVs). The DVs of both compartments were found to correlate with fractional palmitate oxidation rate (FPOR) in experiments in normoxic and hypoxic conditions. The correlation was particularly strong for the slower second compartment (DV2 [mL/g dry weight] = 34.1 FPOR [mL/min/g dry weight] - 0.7, r = 0.89). Relatively small levels of diffusible metabolites of FOP were formed in vivo and in isolated rat liver. CONCLUSION: The selective uptake of FOP by liver and the high sensitivity of hepatic FOP DV to changes of HMFAO with CPT-I inhibition and hypoxia suggests potential usefulness for the 3-oxa fatty acid analog in assessments of hepatic mitochondrial oxidation of exogenous fatty acids with PET. These data emphasize that further studies are required to clarify the intracellular disposition of FOP in the liver and test its validity as a tracer of HMFAO over a broad range of conditions.  相似文献   

13.
In this study, we prepared 2-(2,6-dioxopiperidin-3-yl)-4-[(18)F]fluoroisoindole-1,3-dione (4-[(18)F]fluorothalidomide; [(18)F]1) for the in vivo studies of angiogenesis. Radiochemical synthesis of [(18)F]1 was carried out by labeling 4-trimethylammoniumthalidomide trifluoromethanesulfonate with nBu(4)N[(18)F]F in dimethyl sulfoxide (DMSO), followed by reverse-phase HPLC purification. Decay-corrected radiochemical yield of [(18)F]1 was 50-60%, with an effective specific activity of 42-120 GBq/micromol (end of synthesis). Incubation of the radioligand with human umbilical vein endothelial cells (HUVEC-C; American Type Culture Collection) showed a time-dependent increase in the uptake of the radioligand, and the uptake was inhibited by 8-11% in the presence of 10 microM thalidomide, indicating nonspecific binding of the radioligand. Positron emission tomography (PET) images of mice implanted with tumors in their right flanks revealed a marked accumulation of radioactivity in the livers, kidneys and bladders of the mice, and brain uptake appeared at approximately 40 min after injection. However, no radioactivity uptake was detected in the implanted tumor. Thin-layer chromatography (TLC), HPLC and LC-MS analyses of mouse liver microsomal metabolites of [(18)F]1 and 1 with or without nicotinamide adenine dinucleotide phosphate (NADPH) clearly revealed that the radioligand did not go through metabolic activation but underwent nonenzymatic hydrolysis at physiological pH. Therefore, these results would appear to indicate that [(18)F]1 may not be suitable for the in vivo studies of angiogenesis at least in mice, although it was reported that thalidomide and/or its hydrolysis products may be responsible for its activity in humans.  相似文献   

14.
A fluorinated analog of proline amino acid, cis-4-[(18)F]fluoro-L-proline (FP), was tested for potential use in PET for detection and evaluation of pulmonary response to respirable crystalline silica. The purpose of the study was to determine whether PET imaging with FP is sensitive for detection of pulmonary fibrosis. METHODS: Experimental silicosis was produced in rabbits by airway instillation of 300 mg respirable silica in 0.9% sterile saline; control rabbits received only saline. After 1, 2, 4, or 5 mo, animals were injected with 37 MBq (1 mCi) FP, and imaged in sets of 2 to 3 in a PET scanner using a dynamic scanning protocol over a 3-h period. Each imaging set contained at least 1 control rabbit. FP uptake in each lung was scored from 0 to 5 (PET score) by consensus of 3 readers blinded to animals' exposure status. Animals were humanely killed 2 d after the last imaging, and tissue sections from each lung lobe were graded from 0 to 5 by histopathology examination (histopathology score) for severity and distribution of fibrosis. RESULTS: Silicotic animals had significantly higher (P < 0.05) PET scores at each time point than did control animals. Repeated-measures ANOVA showed significant differences in PET scores between silicotic and control animals for the total lung field, but there were no statistically significant time trends for either group. Presence of fibrosis (i.e., histopathology score > 1) showed a significant association with elevated PET score (i.e., PET score > 1) using Fisher's exact test (P < 0.05). PET scores also showed excellent predictive ability, as all animals (18/18) with fibrosis also had elevated PET scores, and 95% (18/19) of animals with PET scores > 1 showed evidence of fibrosis. Localization of activity to specific lung areas was less exact, perhaps due in part to the small animal size for the resolution of the clinical PET imager used. PET scores were elevated (>1) for 67% (10/15) of silicotic right lungs and 75% (12/16) of silicotic left lungs; fibrosis scores > 1 were measured in 91% (10/11) of right lungs with PET scores > 1, and in 92% (12/13) of such left lungs. CONCLUSION: The FP tracer provided sensitive and specific identification of silicotic animals in early stages of the disease. This suggests that FP PET imaging has the potential sensitivity to detect active fibrosis in silicosis and other lung diseases. Additional studies are needed to determine the specificity of the FP tracer for fibrosis versus inflammatory processes.  相似文献   

15.
A reliable radiosynthesis of 3'-deoxy-3'-[(18)F]fluorothymidine ([(18)F]FLT) has been developed based on [(18)10 mCi (370 MBq) of radiochemically pure [(18)1 Ci/micromol (37 GBq/micromol) at EOS within 100 min and in 13% radiochemical yield (end of bombardment (EOB); 7% end of synthesis (EOS)). [(18)F]FLT has been designed as a new positron emission tomography imaging agent for visualizing cellular proliferation in vivo based on the metabolism of thymidine.  相似文献   

16.
We synthesized [(18)F]FCWAY, an analog of [carbonyl-(11)C]WAY-100635 ?[(11)C]N-(2-(1-(4-(2-methoxyphenyl)-piperazinyl)ethyl))-N-(2-(pyridi nyl))cyclohexanecarboxamide?, by replacing the cyclohexanecarbonyl group acid with a trans-4-fluorocyclohexanecarbonyl group (FC). Control and preblocking studies were performed in anesthetized monkeys. Plasma radioactive metabolite analysis showed the presence of [(18)F]FC and [(18)F]fluoride. Tissue time-radioactivity curves were corrected for metabolite contamination based on separate positron-emission tomography studies of these two labeled metabolites. Analysis using a two-tissue compartment model gave distribution volume (V) estimates (mL/mL) ranging from 33 in frontal cortex to 4 in cerebellum. Preblocking data showed uniform V of 2-3 mL/mL. These studies demonstrate that [(18)F]FCWAY has very similar kinetic characteristics to [(11)C]WAY-100635.  相似文献   

17.
A series of biodistribution studies were conducted with the radiotracer, [(18)F]N-(4'-fluorobenzyl)-4-(3-bromophenyl)acetamide, [(18)F]1 in nude mice bearing tumor xenografts of the mouse mammary adenocarcinoma, line 66. This radiotracer has a high affinity for both sigma(1) and sigma(2) receptors. In vivo studies were also conducted in order to assess the effect of blocking sigma(1) receptors on tumor uptake and the tumor:background ratio of this radiotracer. The results of these studies revealed that blocking the sigma(1) receptor so that only the sigma(2) receptors are labeled in vivo, results in a higher tumor:background ratio with only a small reduction in the tumor uptake of the radiotracer relative to the no-carrier-added (i.e., nonselective) conditions. Comparative in vivo studies were also conducted with the anatomic and metabolic imaging agent, [(18)F]FDG, and a radiolabeled DNA precursor, [(125)I]IUdR. Both of these radiolabeled compounds represent classes of agents that have been proposed for imaging the proliferative status of solid tumors. The results of these studies indicated that a sigma(2)-selective imaging agent may be, 1) a better anatomic imaging agent for breast cancer than [(18)F]FDG, and 2) a better functional imaging agent than the radiolabeled DNA precursors, [(123/124)I]IUdR and [(11)C]thymidine, for measuring the proliferative status of breast tumors with PET and SPECT. However, additional studies will be needed to compare sigma(2)-selective imaging agents with [(18)F]FLT in order to determine which is the more appropriate imaging agent for measuring the proliferative status of breast tumors with PET.  相似文献   

18.
An electrochemical method with the ability to conduct 18F-fluorination of aromatic molecules through direct nucleophilic fluorination of cationic intermediates is presented in this paper. The reaction was performed on a remote-controlled automatic platform. Nucleophilic electrochemical fluorination of tert-butyloxycarbonyl (Boc) protected catechol, an intermediate model molecule for the positron emission tomography (PET) probe (3,4-dihydroxy-6-[18F]fluoro-l-phenylalanine), was performed. Fluorination was achieved under potentiostatic anodic oxidation in acetonitrile containing Et3N·3HF and other supporting electrolytes. Radiofluorination efficiency was influenced by a number of variables, including the concentration of the precursor, concentration of Et3N·3HF, type of supporting electrolyte, temperature and time, as well as applied potentials. Radio-fluorination efficiency of 10.4±0.6% (n=4) and specific activity of up to 43 GBq/mmol was obtained after 1 h electrolysis of 0.1 M of 4-tert-butyl-diboc-catechol in the acetonitrile solution of Et3N·3HF (0.033 M) and NBu4PF6 (0.05 M). Density functional theory (DFT) was employed to explain the tert-butyl functional group facilitation of electrochemical oxidation and subsequent fluorination.  相似文献   

19.
We synthesized a novel (18)F-labeled dopamine D(4) receptor antagonist (Ki=4.3 nM), 3-(4-[(18)F]fluorobenzyl)-8-methoxy-1,2,3,4-tetrahydrochromeno[3,4-c]pyridin-5-one ([(18)F]FMTP), which has exhibited high affinity and selectivity. Radiosyntheses were accomplished by the reaction of fluorine-18-labeled intermediate with 8-methoxy-1,2,3,4-tetrahydrochromeno[3,4-c]pyridin-5-one (1) followed by HPLC purification. The overall radiochemical yield of the radiosynthesis was 19.5% (decay corrected), the specific radioactivity was about 110 GBq/micromol and the radiochemical purity was greater than 99%, the time of synthesis and purification was approximately 110 min. Tissue distribution studies of the [(18)F]FMTP in rats showed that the radioactivity in the brain was concentrated in frontal cortex and medulla, the region that has a high density of D(4) receptors. Pre-treatment with nonradioactive FMTP (1.0mg/kg) produced a significant reduction of radioactivity in all the regions. About 40% of total radioactivity in plasma and 100% in rat brain extract represented unchanged radioligand at 60 min after injection as determined by HPLC. These results indicate that [(18)F]FMTP have some specific binding to the D(4) receptor.  相似文献   

20.
Recent reports have indicated the value of [(18)F]FDG PET and (201)Tl SPECT in diagnosing lung cancer. In this study, we compared the diagnostic value of FDG PET and (201)Tl SPECT in the evaluation of pulmonary nodules. METHODS: Sixty-three patients with 66 pulmonary nodules suspected to be lung cancer on the basis of chest CT were examined by FDG PET and (201)Tl SPECT (early and delayed scans) within a week of each study. For semiquantitative analysis, the standardized uptake value (SUV) or the tumor-to-nontumor activity ratio (T/N) (or both) was calculated. All of these lesions were completely removed thoracoscopically or by thoracotomy and were examined histologically. RESULTS: Fifty-four nodules were histologically confirmed to be malignant tumors, and 12 were benign. Both techniques delineated focal lesions with an increase in tracer accumulation in 41 of 54 lung cancers. (201)Tl SPECT on early or delayed scans (or both) identified 4 additional lung cancers that FDG PET images did not reveal: 3 bronchioloalveolar carcinomas and a well-differentiated adenocarcinoma. FDG PET identified 3 additional lung cancers that (201)Tl SPECT images did not reveal; 2 of these lung cancers were <2 cm in diameter. The mean FDG SUV and T/N of bronchioloalveolar carcinomas (2.06 +/- 0.76 and 3.49 +/- 1.03, respectively) were significantly lower than those of poorly differentiated adenocarcinomas (5.55 +/- 2.01 [P = 0.026] and 8.23 +/- 2.16 [P = 0.01], respectively). However, no significant difference was found in (201)Tl T/N on early and delayed scans between bronchioloalveolar carcinomas (1.64 +/- 0.29 and 1.87 +/- 0.42, respectively) and poorly differentiated adenocarcinomas (1.58 +/- 0.32 and 2.76 +/- 1.36, respectively). Of the 12 benign nodules, FDG PET and (201)Tl SPECT showed false-positive results for the same 7 benign nodules (58.3%) (4 granulomas, 1 sarcoidosis, 1 inflammatory pseudotumor, and 1 aspergilloma). Negative FDG PET findings and positive (201)Tl SPECT findings were obtained only for bronchioloalveolar carcinomas or a well-differentiated adenocarcinoma but not for other histologic types of lung cancers or benign pulmonary nodules. CONCLUSION: No significant difference was found between FDG PET and (201)Tl SPECT in specificity for the differentiation of malignant and benign pulmonary nodules. The degree of differentiation of lung adenocarcinoma correlated with FDG uptake but not with (201)Tl uptake. Bronchioloalveolar carcinoma (a well-differentiated, slow-growing tumor) findings typically were positive with (201)Tl but were negative with FDG. The combination of FDG PET and (201)Tl SPECT may provide additional information regarding the tissue characterization of pulmonary nodules.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号