首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Stress T1-201 myocardial scintigraphy was carried out in 16 patients with X-syndrome. 11 patients with ischaemic heart disease (IHD) with single vessel disease served as controls. With bicycle exercise test all 16 pts with X-syndrome had various types of myocardial perfusion abnormalities. These perfusion defects were situated in the vascular beds of different coronary arteries. Myocardial perfusion defects in patients with X-syndrome were similar to those in patients with moderate, but haemodynamically significant, single vessel disease. At the same time, these perfusion defects were significantly less pronounced than those in patients with subtotal occlusion of one coronary artery. Thus, patients with X-syndrome not only have clinical features of IHD (anginal attacks), but have marked stress-induced myocardial perfusion defects.  相似文献   

3.
BACKGROUND: Nonuniform attenuation artifacts may reduce the diagnostic accuracy of cardiac single photon emission computed tomography (SPECT) studies. Compensation strategies using an attenuation map (eg, from x-ray tomography) have been reported to improve accuracy. Because the computed tomography (CT) and SPECT images are obtained sequentially, misregistration of the emission and transmission scans can occur. Our objective was to qualitatively assess these misregistration errors. METHODS AND RESULTS: This study included 60 patients who consecutively underwent CT attenuation-corrected myocardial perfusion studies acquired on a SPECT/CT system equipped with a nondiagnostic CT scanner. The cardiac SPECT/CT and fused images were reviewed and qualitatively assessed for misregistration of the heart between the CT and emission image data sets. The degree of misregistration was qualitatively rated on a 5-point scale. Misregistration was judged to be none in 4 of 55 patients, minimal in 9, mild in 19, moderate in 21, and severe in 2 patients. Five studies could not be assessed because of severe artifacts on CT. CONCLUSIONS: Forty-two percent of the CT attenuation-corrected myocardial perfusion studies had moderate to severe cardiac misregistration qualitatively. Our data suggest that careful review of attenuation correction maps and registration is needed to avoid reconstruction artifacts due to misregistration.  相似文献   

4.
BACKGROUND: We determined the prognostic value of myocardial perfusion imaging (MPI) in patients with atypical clinical presentations and unexpected elevation of cardiac troponin I (cTnI) levels. METHODS AND RESULTS: In 156 consecutive patients with atypical presentations for acute coronary syndromes (ACS) and elevated cTnI levels undergoing MPI within 30 days, rates of all-cause mortality (100% follow-up; median follow-up, 611 days) and 6-month cardiac death and nonfatal myocardial infarction (96% follow-up; median follow-up, 167 days) were determined. The mean age of the patients was 68 +/- 14 years. The majority of the study cohort (96%) was at low to intermediate clinical risk for ACS (Thrombolysis in Myocardial Infarction score for unstable angina/non-ST-segment elevation myocardial infarction <5). The overall event rate was high, with 45 deaths (28.8%). There were 13 cardiac deaths/nonfatal myocardial infarctions in 6 months (8.3%). A normal MPI result was associated with a high event-free survival rate, whereas an abnormal MPI result was associated with a 3-fold and 7-fold higher risk of all-cause mortality and 6-month cardiac events, respectively. An abnormal MPI result was an independent predictor of all-cause death. CONCLUSIONS: In patients with cTnI elevation and a low to intermediate risk for ACS, a normal MPI result portends a good prognosis. Patients with abnormal MPI results have a higher 6-month cardiac event rate and a worse survival rate.  相似文献   

5.
6.
7.
BACKGROUND: Ventricular remodeling is predictive of congestive heart failure (CHF). We aimed to automatically quantify a new myocardial shape variable on gated myocardial perfusion single photon emission computed tomography (SPECT) (MPS) and to evaluate the association of this new SPECT parameter with the risk of hospitalization for CHF. METHODS AND RESULTS: A computer algorithm was used to measure the 3-dimensional (3D) left ventricular (LV) shape index (LVSI), derived as the ratio of maximum 3D short- and long-axis LV dimensions, for end systole and end diastole. LVSI normal limits were obtained from stress technetium 99m sestamibi MPS images of 186 patients (60% of whom were men) (control subjects) with a low likelihood of CAD (< 5%). These limits were tested in a consecutive series of 93 inpatients (85% of whom were men) having MPS less than 1 week after hospitalization, of whom 25 were hospitalized for CHF exacerbation. Variables associated with CHF hospitalization were tested by receiver operating characteristic curve and multivariate logistic regression analyses. LVSI repeatability was assessed in 52 patients with ischemic cardiomyopathy who had sequential stress MPS within 60 days after the initial MPS without clinical events in the interval between MPS studies. Control subjects had lower end-systolic and end-diastolic LVSIs compared with patients with CHF and those without CHF (P < .001). Receiver operating characteristic curve areas for the prediction of hospitalization as a result of CHF were similar for LV ejection fraction and end-systolic LVSI. End-systolic and end-diastolic LVSIs were independent predictors of CHF hospitalization by multivariate analysis; however, end-systolic LVSI had the greatest added value among all tested variables. Repeatability was excellent for both end-systolic LVSI (R2 = 0.85, P < .0001) and end-diastolic LVSI (R2 = 0.82, P < .001). CONCLUSION: LVSI is a promising new 3D variable derived automatically from gated MPS providing highly repeatable ventricular shape assessment. Preliminary findings suggest that LVSI might have clinical implications in patients with CHF.  相似文献   

8.
9.
10.
11.
12.
BACKGROUND: The purpose of this study was to investigate cardiac events in patients with transient left ventricle (LV) dilation on stress myocardial perfusion single-photon emission computed tomography images (MPI). METHODS AND RESULTS: Consecutive patients (n=53, 31 males, mean age 71 years) with transient LV dilation on thallium-201 stress MPI (treadmill: 21, pharmacologic: 32) were followed for 17 months. Follow-up time was censored at the occurrence of cardiac death, congestive heart failure, acute coronary syndrome, or revascularization. Images were scored and then the summed stress score (SSS), summed rest score, and summed difference score were calculated. Cardiac death occurred in 3 patients, hospitalization occurred in 8 patients, and revascularization occurred in 20 patients. The combined cardiac event rate was 59% (76% for exercise stress vs 47% for pharmacologic stress, p=0.034). Cox regression analysis demonstrated that a combination of higher SSS and slow washout rate was the best predictor of cardiac events (hazard ratio =3.3, p=0.029). CONCLUSIONS: A high cardiac event rate is associated with transient LV dilation on thallium-201 stress MPI. The event rate is particularly high for exercise stress MPI. Furthermore, a combination of the SSS and thallium-201 slow washout is the best predictor of cardiac events in patients with transient LV dilation.  相似文献   

13.
14.
15.
Dobutamine stress myocardial perfusion imaging   总被引:7,自引:0,他引:7  
In patients with limited exercise capacity and (relative) contraindications to direct vasodilators such as dipyridamole or adenosine, dobutamine stress nuclear myocardial perfusion imaging (DSMPI) represents an alternative, exercise-independent stress modality for the detection of coronary artery disease (CAD). Nondiagnostic test results (absence of reversible perfusion defects with submaximal stress) do occur in approximately 10% of patients. Serious side effects during DSMPI are rare, with no death, myocardial infarction or ventricular fibrillation reported in three DSMPI safety reports for a total of 2,574 patients. On the basis of a total number of 1,014 patients reported in 20 studies, the sensitivity, specificity and accuracy of the test for the detection of CAD were 88%, 74% and 84%, respectively. Mean sensitivities for one-, two- and three-vessel disease were 84%, 95% and 100%, respectively. The sensitivity for detection of left circumflex CAD (50%) was lower, compared with that for left anterior descending CAD (68%) and right CAD (88%). The sensitivity of predicting multivessel disease by multiregion perfusion abnormalities varied widely, from 44% to 89%, although specificity was excellent in all studies (89% to 94%). In direct diagnostic comparisons, DSMPI was more sensitive, but less specific, than dobutamine stress echocardiography and comparable with direct vasodilator myocardial perfusion imaging. In the largest prognostic study, patients with a normal DSMPI study had an annual hard event rate less than 1%. An ischemic scan pattern provided independent prognostic value, with a direct relationship between the extent and severity of the perfusion defects and prognosis. In conclusion, DSMPI seems a safe and useful nonexercise-dependent stress modality to detect CAD and assess prognosis.  相似文献   

16.
17.
H A Ziessman  J W Keyes  L M Fox  C E Green  S M Fox 《Chest》1989,96(5):1031-1035
Stress 201Tl myocardial perfusion studies are useful in differentiating viable, reversibly ischemic from infarcted myocardium. A perfusion defect that shows redistribution 2 to 4 h after 201Tl injection is diagnostic of ischemia, while a fixed defect suggests infarction. However, occasional patients with a fixed defect at 4 h have redistribution at 24 h. This study evaluates the frequency and significance of this delayed redistribution with SPECT 201Tl. Patients with either no or incomplete redistribution at 4 h had repeat imaging 18 to 48 h later. Delayed redistribution was seen in 8/26 (31 percent). Four had incomplete and four had no redistribution at 4 h. Delayed redistribution with SPECT 201Tl is more common than generally appreciated, and we recommend delayed images in patients with fixed perfusion defects or incomplete redistribution at 4-h imaging, particularly in patients with previous infarctions for whom a revascularization procedure is being considered.  相似文献   

18.
19.
Sixty-five patients were studied with stress electrocardiography and thallium-201 relative myocardial perfusion scintigraphy. Results were correlated with selective coronary angiography. Scintigraphy was more sensitive (85 versus 67 percent), more specific (89 versus 63 percent) and significantly more accurate (87 versus 65 percent) than stress electrocardiography for the diagnosis of significant coronary arterial lesions in patients with isoelectric S-T segments at rest. Stress scintigraphy helped clarify the equivocal stress test due to left bundle branch block, left ventricular hypertrophy, drugs, hyperventilation and other conditions and was more accurate than the stress electrocardiogram (89 versus 53 percent) even in the presence of a depressed S-T segment at rest. Thallium-201 scintigraphy is a safe and simple noninvasive method for identifying abnormal myocardial perfusion, stress-induced ischemia and, indirectly, significant coronary arterial lesions.  相似文献   

20.
目的 比较负荷与静息门控核素心肌灌注SPECT显像(G-MPS)相位分析技术(SyncTool)所测定的左心室不同步参数之间是否存在差异.方法 回顾性入选行负荷/静息G-MPS的正常对照组患者60例、心肌缺血组患者40例和心功能不全组患者40例,各有一半接受运动或腺苷负荷G-MPS.应用SyncTool对负荷/静息G-MPS短轴图像进行相位分析,计算出左室不同步参数相位标准差(PSD)和相位直方图带宽(PHB).结果 各组患者运动负荷与静息G-MPS的左心室不同步参数(PSD、PHB)均无明显差异(P>0.05),腺苷负荷与静息G-MPS的上述参数也均无明显差异(P>0.05).将心功能不全组分为缺血性心肌病与扩张型心肌病两个亚组,各亚组负荷与静息G-MPS的左心室不同步参数(PSD、PHB)均无明显差异(P>0.05).结论 负荷试验(运动或腺苷)后1小时采集的99Tcm-sestamibi G-MPS所获得的PSD和PHB与静息G-MPS所获得的上述参数无显著差异,常规负荷G-MPS可以用于左心室同步性分析.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号