相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
马永娟  孟庆敏  王彬 《职业与健康》2010,26(16):1886-1887
目的了解佳木斯市透析用水、透析液的细菌污染状况。方法采集佳木斯市8家医院反渗水及透析液标本,对反渗水及透析液标本进行细菌培养和菌落计数,用鲎试剂定性检测内毒素。结果反渗水细菌培养有2家医院阳性,细菌总数均为300 CFU/ml,内毒素检测均〈2 EU/ml;A浓缩透析液内毒素均〈2 EU/ml;B浓缩透析液内毒素均〈2 EU/ml;透析器入口细菌培养3家阳性,内毒素检测有2家〉2 EU/ml。结论目前,佳木斯市部分血液净化中心仍存在反渗水及透析液的细菌污染,应定期检测反渗水、透析液的内毒素水平及进行细菌培养,定期消毒反渗水装置及透析液容器,对减少热源反应至关重要。  相似文献   

2.
目的了解重庆市医院透析室透析用水、透析液的内毒素及细菌污染情况。方法采集该市8家三级甲等医院透析用水及透析液标本,进行细菌培养和菌落计数;用ATi动态试管仪测定反渗水及透析液中内毒素含量。结果 8家医院透析用水细菌培养计数均≤200 CFU/mL,1家医院透析液细菌计数2 000 CFU/mL,培养出的细菌以革兰阴性菌为主;透析用水内毒素均2 EU/mL。结论目前重庆市大部分医院血液透析室的透析用水符合国家标准,但仍有部分医院透析液存在细菌污染。应定期检测透析用水、透析液中的内毒素和进行细菌培养,保障医疗安全。  相似文献   

3.
一次透析液和透析用水细菌污染的调查与分析   总被引:10,自引:2,他引:8  
目的了解血透室透析液和透析用水细菌含量超标的原因,找出污染的途径和环节. 方法按卫生部<医院感染管理规范>的要求检测细菌含量,并鉴定细菌种类. 结果透析用水(反渗水)平均细菌数为(97.79±11.64)CFU/ml,透析液平均细菌数为(312.33±8.26)CFU/ml,A液和B液平均细菌数为(0.82±2.32)CFU/ml和(207.11±5.56)CFU/ml,反渗水和B液细菌含量严重超标,且培养出革兰阴性杆菌. 结论血液透析液和透析用水细菌污染与浓缩B液配制过程污染和透析用水管道细菌污染及反渗透装置未及时更换有关.  相似文献   

4.
血液透析室透析液及透析用水的细菌学监测   总被引:7,自引:5,他引:7  
目的了解血液透析室透析液及透析用水细菌污染的原因及对策. 方法检测血液透析液及透析用水中细菌的含量及细菌种类. 结果透析器入口处透析液的平均菌落数为486 CFU/ml,透析器出口处透析液的平均菌落数为490 CFU/ml,反渗水的平均菌落数为103 CFU/ml,常见细菌为枯草杆菌、类白喉杆菌及某些革兰阴性杆菌. 结论透析液在配制的过程中,有多种环节可能造成污染,应加强透析液的监测工作,并建议修改透析液细菌监测的标准.  相似文献   

5.
目的 对血液透析用水、透析液开展质量监测.方法 按《中国药典》方法做微生物限度、细菌内毒素检查、化学污染物等检验.结果 微生物学检验结果符合国家食品药品监督管理局发布的医药行业标准YY0572-2005中规定的要求,但经贮水容器和输水管路出口的透析用水中,细菌内毒素由0.125 Eu/ml增加至0.25 Eu/ml,真菌数由10 CFU/200 ml增加至150CFU/200 ml,硝酸盐浓度增高约5倍.结论 透析用水、透析液应每日现制现用,注意消毒和冲洗各输液管路.  相似文献   

6.
滕朝宇 《医疗卫生装备》2010,31(10):136-137
目的:研究水处理系统中反渗膜及管路对透析用水质量的影响。方法:采用统一的透析调查表对2006年度长沙市20家透析单位进行调查。选择血液透析水处理系统易于取样又能代表水处理污染情况的4点(原水、反渗水1(配制B液取样点)、反渗水2(进入透析机前取样点)、透析器入口透析液取样点)采水样进行内毒素定性检测。结果:管路定期消毒时间的长短,水处理系统是否设计有储水罐,管路设计是否有死腔、死腔次环路、热消毒管道,以及反渗透膜的使用时间等,对透析用水及透析液的质量均有显著影响。结论:透析用水的卫生质量与水处理系统使用年限、是否及时更换和消毒、管路设计有无死腔与储水罐以及A、B液配制等有关;透析用水及透析液双级反渗优于单级反渗水处理系统。  相似文献   

7.
血液透析细菌感染预防与对策   总被引:2,自引:2,他引:0  
目的了解医院血液透析中心透析液、透析用水水质状况,分析细菌内毒素及菌落数超标的原因及相关性,实现规范化管理的同时督促持续质量改进。方法收集分析自2006年1月-2010年7月透析用水和透析液的监测数据,分别比较A、B两种方法,水处理管路更换前后监测结果,对透析用水、透析液现场采样并对照监测细菌菌落数及内毒素,为采取防治对策提供依据。结果使用不同的内毒素检测方法对透析液、透析用水内毒素检测合格率差异有统计学意义,A方法为69.23%,B方法为100.00%;对照透析液、透析用水细菌菌落数与内毒素含量,两者差异无统计学意义,细菌菌落数合格率为81.58%,内毒素合格率为90.79%。结论探索一种科学可行的内毒素含量检测方法;透析用水、透析液含菌量与内毒素含量不成正比;透析用水、透析液的水质状况与水处理系统管路长短、有无死腔、使用年限、有无生物膜形成,配制过程是否被污染有关,重在预防。  相似文献   

8.
目的分析配制透析液过程中的污染因素,寻找控制污染的有效方法。方法分两阶段即装透析液的容器消毒和不消毒,收集各采样点的水标本和透析液标本做细菌培养,根据结果分析污染原因。结果透析用水、透析器入口液细菌培养结果均达到相关标准,即透析用水菌落数≤200CFU/mL,透析液菌落数≤2 000CFU/mL。未消毒容器内透析B液细菌污染严重,分装前检出菌落数为(474.00±292.22)CFU/mL,分装后为(492.22±311.11)CFU/mL;消毒容器内透析B液细菌控制在理想范围,分装前为(9.38±6.19)CFU/mL,分装后为(5.04±4.38)CFU/mL;容器消毒与否,透析B液细菌检出数差异有显著性(P<0.01)。结论保证高质量的透析液,除了应加强水处理系统、送水管道、配液容器、透析机和血路管、透析器等各个环节的严格消毒外,还需严格监控自配透析液的过程。  相似文献   

9.
滕朝宇 《医疗装备》2010,23(5):30-31
本文对长沙市部分透析单位的透析用水及透析液质量的状况进行了调查,从内毒素、游离氯、硬度测试三方面检测、分析,提出改善透析用水的质量的办法,以及透析用水、透析液的卫生质量与水处理系统使用时间和反渗膜、活性炭、软水器及时更换、定期维护及管路消毒与更换,与管路设计有无死腔、有无储水罐等得关系。以进一步提高长沙市透析单位透析用水及透析液的质量。  相似文献   

10.
 目的 掌握某省医院血液透析中心的水处理系统管理和维护现状,分析反渗膜及管路消毒等相关因素与透析用水检出细菌菌落总数、内毒素水平的关系,识别风险因素并探讨改进措施。方法 采集18所医院血液透析中心反渗机组出水口和输水管路回水口透析用水,经薄膜过滤法富集,在20℃下TGEA培养168 h,进行细菌菌落计数,平行水样检测内毒素。同时设计问卷调查水处理系统管理和维护信息。结果 采样距反渗膜更换间隔时长与回水口菌落总数、回水口及出水口内毒素呈正相关。采样距上一次管路消毒间隔时间与回水口和出水口内毒素呈负相关,专业工程师配备与回水口菌落总数及出水口内毒素呈负相关,软管长度与回水口内毒素呈正相关。回归分析结果显示,投入使用时长、透析机台数、在透析患者数等因素也对透析用水微生物指标有影响。结论 反渗膜的维护更换、输水管路消毒、专业工程师配备、透析中心规模及管路长度均为透析用水微生物指标的主要影响因素。各医院的水处理系统管理和维护存在差异,应通过质量控制推进使其达到同质化。  相似文献   

11.
12.
Voluntary discontinuation of chronic dialysis treatment accounted for 8% of the mortality in a chronic dialysis population (n = 167) between 1979 and 1989. Mean age of these 13 patients was 54 years and the time on dialysis 105 months. All of them were mentally competent at the time the decision was made. Ten patients took the decision entirely on their own; only 5 of the patients were living at home with their partners. Severe somatic comorbidity was found in all 13 patients, but in 5 of them no acute event could be identified. In 3 patients psychiatric pathology was present; they were significantly younger and the duration of dialysis therapy was shorter than in the other 10 patients. The results of this investigation are compared with findings from the literature.  相似文献   

13.
14.
This article explores home dialysis provision among freestanding renal facilities by examining whether they provide continuous ambulatory peritoneal dialysis (CAPD), continuous cycling peritoneal dialysis (CCPD), and home hemodialysis. These modalities require fewer visits to a dialysis center, which may be beneficial for patients living long distances from facilities. A negative association was found between the number of facilities per square mile and the probability of provision of the home modalities. Secondly, facilities with a higher percent of black patients were less likely to provide the home modalities. Thirdly, facilities with larger numbers of patients were more likely to provide the home modalities.  相似文献   

15.
ISTVAN L  ZSAMBEKY P 《Orvosi hetilap》1956,97(19):507-513
  相似文献   

16.
刘加明 《现代预防医学》2012,39(14):3712-3713,3715
目的探讨维持性血液透析患者(MHD)C-反应蛋白(CRP)的变化与透析膜和透析方式的关系。方法回顾性分析某院自2007年1月~2010年10月收治的需进行MHD的患者34例,分别应用血仿膜与聚砜膜,HD与HDF两种不同的透析方式,比较CRP值的变化。同时选取健康人群30例为对照组。结果 MHD组患者CRP水平显著高于正常对照组(P﹤0.000)。血仿膜与聚砜膜对CRP水平无显著影响(P﹥0.05)。HD、PD治疗组的CRP均高于对照组,差异有统计学意义(P﹤0.05),HD组C反应蛋白高于PD组(P﹤0.05)。结论 MHD患者的CPR水平与采用不同的透析膜无光,但采用不同的透析方式可以改善MHD患者微炎症状态。  相似文献   

17.
新管理模式下腹膜透析病人的随访和生存情况分析   总被引:1,自引:0,他引:1  
目的 探讨腹膜透析病人门诊随访管理对生存的影响.方法回顾性分析比较腹膜透析中心144例随访达标的病人和209例随访未达标病人的生存状况以及对影响病人随访达标的因素进行分析.结果 随访末达标病人的死亡风险是随访达标病人的3.691倍(P<0.001).活动能力差的病人,没有医疗保障的病人,外地的病人随访情况较差.结论 加强腹膜透析的门诊管理,提高透析病人的随访率是改善腹膜透析病人生存的关键.  相似文献   

18.
19.
血液透析和腹膜透析的成本分析   总被引:9,自引:4,他引:5  
目的:比较血液透析和腹膜透析的成本构成,为制定、完善医保政策提供依据。方法:对上海市4家医院1999年度血液透析和腹膜透析的成本构成及利润情况进行分析。结果:血液透析均次成本中材料成本占35%-37%,设备成本占38%-44%,其获利的增幅受人(次)数和均次利润的共同影响。腹膜透析均次成本中材料成本超过97%,其获利仅与所服务的人(次)数有关。结论:两种透析方法存在着较大的利润差异,导致血液透析不适宜地扩张,抑制了腹膜透析技术的合理应用。  相似文献   

20.
Polner K 《Orvosi hetilap》2008,149(1):5-11
The author reviews briefly the history of peritoneal dialysis, and highlights the significance of the work of two Hungarian nephrologists, Stephen I. Vas and István Taraba . By now, peritoneal dialysis has been considered as equal renal replacement modality compared to haemodialysis. It is even more advantageous in the protection of the patients' residual renal function, morbidity-mortality indices, and quality of life peritoneal dialysis in the first two years. From economical point of view peritoneal dialysis is less expensive than hemodialysis, therefore in the future its greater role can be expected in the treatment of more and more renal patients. The recently achieved technical development, and also the more widespread use of the automated peritoneal dialysis machines contribute to quality improvement. The peritoneal dialysis therapy, by the patients' self-treatment, establishes a new kind of relationship between the patients and the medical personnel; there is a growing requirement for patient education, the patients' self-esteem and cooperation increase, which altogether provides better results in rehabilitation and higher quality of life. Our national peritoneal dialysis utilization falls behind the European achievements, but has been growing dynamically, and we can expect an increase of the number of renal patients on peritoneal dialysis.  相似文献   