首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到3条相似文献,搜索用时 0 毫秒
1.
A method using a molecularly imprinted polymer (MIP) as the selective sorbent for solid-phase extraction (SPE) has been developed. Its application to the assay of hairy nicotine level among smokers and non-smokers with high-performance liquid chromatography (HPLC) and evaluation of exposures to the environmental tobacco smoke (ETS) were validated. The MIP was synthesized using nicotine as the template molecule and methacrylic acid (MAA) as the functional monomer. This MIP-SPE method provided inherent selectivity and a sensitive response to nicotine with a detection limit of 0.2 ng/ml hair at a signal-to-noise ratio of 3:1 and the limit of quantification was 0.5 ng/ml. The linearity was assessed in the range of 0.5-80 ng/ml hair, with a coefficient (r(2)) greater than 0.987. The amounts of nicotine determined in smokers and non-smokers hair were in the range of 5.1-69.5 ng/mg hair and 0.50-9.3 ng/mg hair, respectively. The reported measures of ETS exposure were significantly associated with hairy nicotine levels. This assay of nicotine in hair using MISPE provided a very selective and reliable method for the evaluation of the exposure to tobacco smoke.  相似文献   

2.
A pressurized capillary electrochromatography (pCEC) with monolithic column has been developed for the rapid separation and determination of five structurally related anthraquinones in Rhubarb. The possibility of rapid separation resulted from the unique pore structure with high permeability and favorable mass transfer characteristics of the monolithic stationary phase. The effect factors such as organic modifier, acidity and concentration of running buffer, separation voltage were investigated to acquire the optimum condition. In the 220 nm wavelengths, the five anthraquinones could be baseline-separated rapidly within 5 min with the separation voltage of -20 kV in 10 mmol/L phosphate buffer (pH 6.2) containing 65% acetonitrile. The calibration graphs of rhein, aloe-emodin, emodin chrysophanol and physcion were linear by plotting the peak area against the analytes concentration over the range of 0.2-65, 0.1-30, 0.1-55, 0.5-30 and 0.5-55 microg/mL, respectively. The detection limits of five anthraquinones were ranged from 0.06 to 0.2 microg/mL and the recoveries of Rhubarb samples were about 81.3-86.4% (R.S.D.< or = 5.2%). This proposed method was successfully applied to determination of the five analytes in Rhubarb with satisfactory results.  相似文献   

3.
The state-of-the-art in CEC enantiomer separations with monolithic capillary columns is comprehensively reviewed. The various types of monolithic columns comprising in situ organic polymer monoliths, molecularly imprinted polymer (MIP) monoliths, silica monoliths and monoliths made from particles are discussed with a focus on materials’ synthesis, chemistry and properties as well as column aspects. Monolithic MIP-type porous layer open-tubular (PLOT) columns are treated herein as well. From this survey of the literature, the authors come to the conclusion that monolithic silica capillaries appear to become the preferred column type for CEC enantiomer separations of low-molecular drugs and other chiral pharmaceuticals or chemicals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号