首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Background: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to determine the local anesthetic-sparing efficacy of epidural epinephrine by its effect on the MLAC of bupivacaine.

Methods: In this double-blind, randomized, prospective study, 70 parturients who were at 7 cm or less cervical dilation and who requested epidural analgesia were allocated to one of two groups. After lumbar epidural catheter placement, 20 ml bupivacaine (n = 35) or bupivacaine with epinephrine 1:300,000 (n = 35) was administered. The concentration of bupivacaine was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores, with 10 mm or less within 30 min defined as effective.

Results: The MLAC of bupivacaine alone was 0.091% wt/vol (95% confidence interval, 0.081-0.102). The addition of epinephrine 1:300,000 (66.7 [mu]g) resulted in a significant reduction (P < 0.01) in the MLAC of bupivacaine to 0.065% wt/vol (95% confidence interval, 0.047-0.083). The lowest maternal blood pressure was significantly lower in the bupivacaine-epinephrine group (P = 0.03). There were statistically significant reductions in fetal heart rate (P = 0.011) in the bupivacaine-epinephrine group that were not clinically significant.  相似文献   


2.
分娩第一产程时布比卡因硬膜外镇痛最低有效浓度的研究   总被引:6,自引:0,他引:6  
目的:探讨并比较硬膜外布比卡因分娩镇痛在第一产程不同阶段的最低局麻药镇痛浓度(MLAC)。方法:随机将60例产妇分为A(潜伏期)、B(活跃期)组,首例均用0.1%布比卡因15ml,其后根据前一例产妇对高或低浓度布比卡因药液的反应,依次变动局麻药的浓度,VAS≤10mm为有效。结果:A组MLAC为0.05%,B组MLAC为0.142%;B组MLAC显著高于A组(P〈0.0001)。结论:第一产程硬膜外布比卡因镇痛的有效浓度为0.05%~0.142%,随产程进展而增高。  相似文献   

3.
Background: Doses for intrathecal opioid-local anesthetic mixtures have been arbitrarily chosen. The aim of this study was to compare the analgesic efficacies of intrathecal ropivacaine, levobupivacaine, and bupivacaine for labor analgesia and to determine the analgesic potency ratios for these three drugs. For this purpose, the authors used the up-down sequential allocation model, which estimates the minimum local analgesic dose for intrathecal local anesthetic.

Methods: Ninety-seven nulliparous term parturients in spontaneous labor, requesting combined spinal-epidural analgesia, were randomly allocated to one of three groups to receive 0.25% spinal ropivacaine, levobupivacaine, or bupivacaine. The initial dose of the local anesthetic drug was chosen to be 2.5 mg, and the testing interval was set at 0.25 mg. The subsequent doses were determined by the response of the previous parturient. Efficacy was accepted if the visual analog pain score decreased to 10 mm or less on a 100-mm scale within 30 min. The minimum local analgesic dose was calculated using the method of Dixon and Massey.

Results: The intrathecal minimum local analgesic dose was 3.64 mg (95% confidence interval, 3.33-3.96 mg) for ropivacaine, 2.94 (2.73-3.16) mg for levobupivacaine, and 2.37 (2.17-2.58) mg for bupivacaine. The relative analgesic potency ratios were 0.65 (0.56-0.76) for ropivacaine:bupivacaine, 0.80 (0.70-0.92) for ropivacaine:levobupivacaine, and 0.81 (0.69-0.94) for levobupivacaine:bupivacaine. There were significant trends (P <= 0.021) for greater motor block with bupivacaine and levobupivacaine.  相似文献   


4.
Background: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration (EC50) in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to determine the relative local anesthetic sparing efficacies of intravenous and epidural fentanyl by comparison of their effects on the MLAC of bupivacaine.

Methods: In this double-blind, randomized, prospective study, 84 parturients at <= 7-cm cervical dilation who requested epidural analgesia were allocated to one of two groups. After lumbar epidural catheter placement, 20 ml bupivacaine (n = 44) or bupivacaine with 3 [mu]g/ml (60 [mu]g) fentanyl (n = 40) was administered. The plain bupivacaine group then received 60 [mu]g intravenous fentanyl. The bupivacaine-fentanyl group received intravenous saline. The concentration of bupivacaine was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores, with <= 10 mm within 30 min defined as effective.

Results: The MLAC of bupivacaine-intravenous fentanyl was 0.064% wt/vol (95% confidence interval, 0.049-0.080), and the MLAC of bupivacaine-epidural fentanyl was 0.034% wt/vol (95% confidence interval, 0.017-0.050). Epidural fentanyl significantly increased the analgesic potency of bupivacaine by a factor of 1.88 (95% confidence interval, 1.09-3.67) compared with intravenous fentanyl. The epidural fentanyl group demonstrated significantly higher dermatomal spread (P = 0.0064) and increased pruritus (P = 0.01).  相似文献   


5.
Background: This study intends to evaluate the benefits of the administration of intermittent bolus doses of ropivacaine (0.125%) compared with bupivacaine (0.125%) after addition of sufentanil for analgesia during labor.

Methods: One hundred thirty American Society of Anesthesiologists physical status 1 or 2 parturients were studied. The 90 initial patients were assigned randomly to receive 10 ml bupivacaine, 0.125%, plus 7.5 [micro sign]g sufentanil (initial bupivacaine 0.125% group) or ropivacaine, 0.125%, plus 7.5 [micro sign]g sufentanil (ropivacaine 0.125% group). Forty additional patients were recruited and received 0.125% bupivacaine plus 7.5 [micro sign]g sufentanil (additional bupivacaine 0.125% group) or 0.100% bupivacaine plus 7.5 [micro sign]g sufentanil (additional bupivacaine 0.100% group). The duration of analgesia, visual analogue scores for pain, motor blockade (using a six-point modified Bromage scale), patient satisfaction scores, nausea, pruritus, heart rate, and blood pressure were recorded.

Results: Bupivacaine 0.125% and ropivacaine 0.125% coadministered with sufentanil provided rapid and complete analgesia. Onset of analgesia occurred after +/- 15 min and lasted +/- 90 min. After the third epidural injection, patients in the ropivacaine group experienced significantly less severe motor blockade than patients in the initial bupivacaine 0.125% group. At this point, 93% of the patients in the ropivacaine group were free from motor impairment versus 66% in the bupivacaine group (P < 0.05). Comparable levels of motor blockade were obtained in both additional groups. Patients' evaluation of their analgesia was worst in the bupivacaine 0.100% group.  相似文献   


6.
Background: The aim of this prospective, double-blind, sequential allocation study was to compare the effects of spontaneous and prostaglandin-induced labor on the minimum analgesic dose of epidural sufentanil in the first stage of labor.

Methods: Seventy healthy, nulliparous women, at more than 37 weeks' gestation with cervical dilatation from 2 to 4 cm, requesting epidural pain relief in labor were enrolled. The subjects were assigned to two different groups according to whether labor was spontaneous or induced with dinoprostone 0.5 mg. Parturients received 10 ml of the study solution through a lumbar epidural catheter. The initial dose was sufentanil 25 [mu]g, and subsequent doses were determined by the response of the previous patient in the same group using up-down sequential allocation. The analgesic effectiveness was assessed using 100-mm visual analog pain scores. The up-down sequences were analyzed using the method of independent paired reversals and probit regression.

Results: The minimum analgesic dose of sufentanil in spontaneous labor was 22.2 [mu]g (95% CI: 19.6, 22.8) and 27.3 [mu]g (95% CI: 23.8, 30.9) in induced labor. The minimum analgesic dose of sufentanil in induced labor was significantly greater (P = 0.0014) than that in spontaneous labor (95% CI difference: 2.9, 9.3) by a factor of 1.3 (95% CI: 1.1, 1.5).  相似文献   


7.
Objectives: To determine the Minimum local analgesic concentration (MLAC) of epidural lidocaine for herpetic neuralgia. Methods: Thirty-one cases of thoracic herpetic neuralgia patients received thoracic epidural catheterization under the guidance of the digital subtraction angiography (DSA), securing the end of catheter to the side gap of lesions of the central segmentation of epidural affected by herpes zoster. An injection of iohexol mixed with lidocaine under the guidance of DSA to make sure that drug solution covered all injured nerve roots. The first patient was administered 0.37% lidocaine weight by volume; subsequent patients received a concentration determined by the response of the previous patient to a higher or lower concentration according to up and down sequential allocation in 0.02% increments. Efficacy was assessed using a visual analogue pain scale(VAS), and accepted if this was ≤10 mm on a 100 mm scale within 30 minutes. The median effective concentration (EC50) was estimated with probit regression analysis. Results: A total of 30 patients were successfully completed, except one patient withdraw from the trial due to vascular puncture. The EC50 of epidural lidocaine for herpetic neuralgia was 0.1 99% (95%CI 0.1 68% -0.216%). Conclusions: The MLAC of epidural lidocaine for herpetic neuralgia was 0.199% (95% CI 0.168%-0.216%).  相似文献   

8.
Background: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to assess the relative analgesic potencies of epidural bupivacaine and ropivacaine by determining their respective minimum local analgesic concentrations.

Methods: Seventy-three parturients at Results: The minimum local analgesic concentration of ropivacaine was 0.111% wt/vol (95% confidence interval, 0.100-0.122), and the minimum local analgesic concentration of bupivacaine was 0.067% wt/vol (95% confidence interval, 0.052-0.082). Ropivacaine was significantly less potent than bupivacaine, with a potency ratio of 0.6 (95% confidence interval, 0.49-0.74). No difference in motor effects was observed.  相似文献   


9.
Background: Regional analgesia for labor often is initiated with an intrathecal injection of a local anesthetic and opioid. The purpose of this prospective, randomized, blinded study was to determine the optimal dose of intrathecal sufentanil when combined with 2.5 mg bupivacaine for labor analgesia.

Methods: One hundred seventy parous parturients with cervical dilation between 3-5 cm were randomized to receive intrathecal 0 (control), 2.5, 5.0, 7.5, or 10.0 [mu]g sufentanil combined with 2.5 mg bupivacaine, followed by a lidocaine epidural test dose, for initiation of analgesia (34 patients in each group). Visual analog scores and the presence of nausea, vomiting, and pruritus were determined every 15 min until the patient requested additional analgesia. Fetal heart rate tracings were compared between groups.

Results: Groups were similar for age, height, weight, oxytocin dose, duration of labor, and baseline visual analog scores. Duration of action was significantly shorter for control patients (39 +/- 25 min [mean +/- SD]) compared with those administered sufentanil, all doses (93 +/- 32, 93 +/- 47, 94 +/- 33, 97 +/- 39 min), but was not different among groups administered 2.5, 5.0, 7.5, or 10.0 [mu]g sufentanil. More patients who received 10 [mu]g sufentanil reported nausea and vomiting than did control patients. The severity of pruritus increased with administration of 7.5 and 10.0 [mu]g sufentanil. There was no difference in fetal heart rate changes among groups.  相似文献   


10.
11.
Background: Combining bupivacaine with fentanyl for intrathecal analgesia in labor is well recognized, but dosages commonly used are arbitrarily chosen and may be excessive. This study aimed to determine the median effective dose (ED50) of intrathecal bupivacaine, defined as the minimum local analgesic dose (MLAD), and then use this to assess the effect of different doses of fentanyl.

Methods: In this double-blind, randomized, prospective study, 124 parturients receiving combined spinal epidural analgesia at 2-6-cm cervical dilatation were allocated to one of four groups to receive bupivacaine alone or with 5, 15, or 25 [mu]g fentanyl, using the technique of up-down sequential allocation. Analgesic effectiveness was assessed using 100-mm visual analog pain scores, with less than or equal to 10 mm within 15 min defined as effective. MLAD was calculated using the formula of Dixon and Massey. Pruritus and duration of spinal analgesia were also recorded.

Results: Minimum local analgesic dose of intrathecal bupivacaine was 1.99 mg (95% confidence interval, 1.71, 2.27). There were similar significant reductions in MLAD (P < 0.001) for all bupivacaine-fentanyl groups compared with bupivacaine control. There was a dose-dependent increase in both pruritus and duration of spinal analgesia with increasing fentanyl (P < 0.0001).  相似文献   


12.
Background: The intrathecal combination of sufentanil and bupivacaine provides rapid, effective analgesia for labor with a limited duration. Many anesthesiologists have concerns that the use of intrathecal local anesthetics precludes maternal ambulation. This prospective, randomized, double-blind study was designed to determine whether the addition of epinephrine to the combination of sufentanil and bupivacaine would prolong intrathecal analgesia for labor. Patients' ability to ambulate was also assessed.

Methods: Thirty-nine patients received either an intrathecal control dose of 10 micro gram sufentanil plus 2.5 mg bupivacaine plus 0.2 ml normal saline (control group); or 10 micro gram sufentanil plus 2.5 mg bupivacaine plus 0.2 ml (0.2 mg) of epinephrine (EPI group).

Results: Seven patients (3 control, 4 EPI) delivered vaginally and two (1 control, 1 EPI) required cesarean delivery before requesting epidural analgesia. The duration (mean +/- SD) of intrathecal labor analgesia was prolonged significantly by the addition of epinephrine: control (n = 15): 145 +/- 23 min; EPI (n = 15): 188 +/- 25 min (P <0.0001). Maternal ambulation was demonstrated in 100% (19 of 19) of the control group and in 80% (16 of 20) of the EPI group (P = NS).  相似文献   


13.
Background: This study was designed to determine and compare the minimum local analgesic concentrations of levobupivacaine and ropivacaine when used in epidural obstetric analgesia.

Methods: In a double-blind study, healthy women requiring epidural analgesia for labor pain were randomized to receive either ropivacaine or levobupivacaine. Drugs were administered as a 20-ml epidural bolus. The concentration of each started at 0.11% and increased or decreased at intervals of 0.01%, depending on the response of the previous patient, using the technique of up-down sequential allocation. Minimum local analgesic concentrations were calculated using the formula of Dixon and Massey. Efficacy was assessed using visual analog pain scores and motor and sensory block assessments, and safety was assessed by recording maternal and fetal/neonate vital signs and adverse events.

Results: Forty-seven patients received levobupivacaine, and 47 received ropivacaine. Minimum local analgesic concentrations for levobupivacaine (0.077%; 95% CI, 0.058-0.096%) were lower than those for ropivacaine (0.092%; 95% CI, 0.082-0.102%). The 0.015% difference was not statistically significant. There was no notable difference between treatment groups in the proportion of patients reporting drug-related adverse events.  相似文献   


14.
目的:探讨硬膜外泵注芬太尼与布比卡因用于分娩镇痛的有效性及安全药物剂量。方法:以0.15%布比卡因为对照,比较0.0005%至0.0012%范围内四种不同浓度芬太尼与之混合硬膜外泵注的分娩镇痛效果。结果:选用0.0008%与0.001%两种浓度芬太尼与0.15%布比卡因混合泵注时,镇痛作用起效快,镇痛时间明显延长,而且不增加副作用。结论:硬膜外连续泵注芬太尼与布比卡因用于分娩镇痛能明显改善镇痛效果,芬太尼使用浓度以限制在0.0008%至0.001%为宜。  相似文献   

15.
Background: Regional analgesia techniques for labor that permit ambulation are popular among parturients. This study evaluated the influence of bupivacaine bolus concentration and a 3-ml 1.5% lidocaine-epinephrine test dose, on analgesic effectiveness and the ability to walk after block placement.

Methods: Using a randomized double-blind study design, epidural analgesia was initiated in 60 parturients undergoing labor as follows: Group TD/B.0625 received a 3-ml lidocaine-epinephrine test dose + 12 ml bupivacaine, 0.0625%; group TD/B.125 received a 3-ml test dose + 12 ml bupivacaine, 0.125%; group B.0625 received 15 ml bupivacaine, 0.0625% (no test dose); and group B.125 received 15 ml bupivacaine, 0.125% (no test dose). Initial boluses in all groups contained 10 [mu]g sufentanil. Bupivacaine, 0.0625%, with 0.33 [mu]g/ml sufentanil was infused throughout labor at 13.5-15 ml/h. Analgesia balance, proprioception, motor block, and patient ability to stand and walk were evaluated at various intervals.

Results: A bolus of 0.125% bupivacaine containing sufentanil, without a previous test dose, proved to be optimal with respect to analgesia and early ambulation. When a test dose was given before bupivacaine, 0.125%, fewer women walked within 1 h of block placement. Bupivacaine, 0.0625%, with sufentanil, with or without a test dose, provided inadequate analgesia, necessitating additional bupivacaine, which impaired the ability to walk. A high percentage of women in all groups (73-93%) walked at some stage during labor.  相似文献   


16.
Background: The minimum local analgesic concentration has been defined as the median effective local analgesic concentration (EC50) in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to assess the relative analgesic potencies of epidural levobupivacaine and ropivacaine by determination of their respective minimum local analgesic concentrations.

Methods: Parturients at 7 cm of cervical dilation or less who requested epidural analgesia were allocated to one of two groups in this double-blind, randomized, prospective study. After lumbar epidural catheter placement, 20 ml of the test solution was given: levobupivacaine (n = 35) or ropivacaine (n = 35). The concentration of local anesthetic was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scale scores, with 10 mm or less within 30 min defined as effective. An effective result directed a 0.01% wt/vol decrement for the next patient. An ineffective result directed a 0.01% wt/vol increment.

Results: Of 105 women enrolled, 35 were excluded, leaving 70 for analysis. The minimum local analgesic concentration of levobupivacaine was 0.087% wt/vol (95% CI, 0.081-0.094%), and the minimum local analgesic concentration of ropivacaine was 0.089% wt/vol (95% CI, 0.075-0.103%). Levobupivacaine and ropivacaine were of similar potency with a ropivacaine:levobupivacaine potency ratio of 0.98 (95% CI, 0.80-1.20). No difference in motor effects was observed.  相似文献   


17.
18.
Background: This study evaluated the efficacy of an epidural single dose of neostigmine combined with sufentanil to provide selective and balanced analgesia at the beginning of labor.

Methods: After informed consent, 125 healthy parturients were randomly allocated to receive, after a test dose, a single injection of either epidural sufentanil 20 [mu]g (minimal analgesic dose) or 10 [mu]g or a combination of sufentanil 10 [mu]g with neostigmine 250, 500, or 750 [mu]g in a total volume of 12 ml. Pain scores were recorded at regular intervals to determine onset and duration of analgesia. Maternal and fetal vital parameters as well as side effects were closely monitored.

Results: Parturients did not differ concerning demographic data. Epidural neostigmine 500 [mu]g with sufentanil 10 [mu]g produced effective analgesia (visual analog scale <30 mm within 10 min in 72% parturients and within 15 min in 85% parturients; average duration of 119 min, confidence interval 96-142 min) that was as effective as epidural sufentanil 20 [mu]g. Epidural combination with neostigmine 250 [mu]g was ineffective, whereas 750 [mu]g did not produce higher effect than 500 [mu]g. No motor block was recorded. Maternal and fetal vital parameters remained stable during labor.  相似文献   


19.
Bupivacaine Augments Intrathecal Fentanyl for Labor Analgesia   总被引:1,自引:0,他引:1  
Background: Intrathecal fentanyl has been shown to be an effective analgesic for labor; this study investigated the analgesic effect of low-dose bupivacaine added to intrathecal fentanyl for labor analgesia.

Methods: Ninety parturients in active labor who requested regional analgesia were randomized to receive an intrathecal injection of either fentanyl, 25 [micro sign]g; bupivacaine, 1.25 mg, with fentanyl, 25 [micro sign]g; or bupivacaine, 2.5 mg, with fentanyl, 25 [micro sign]g, as part of a combined spinal-epidural technique. Visual analog pain scores were recorded before and at intervals after injection until the patient requested further analgesia. Maternal blood pressure and fetal heart rate were recorded before and at intervals after injection. Lower-extremity muscle strength was tested before and 30 min after injection; anesthetic level to cold sensation and the presence and severity of pruritus were recorded.

Results: Duration of analgesia was longer in the group receiving bupivacaine, 2.5 mg, and fentanyl, 25 [micro sign]g, than the group receiving plain fentanyl (108 vs. 92 min; P < 0.05). Onset of analgesia was faster in both groups receiving bupivacaine compared with plain fentanyl (P < 0.05). No differences in muscle strength after injection were found in any group, although anesthetic levels to cold were documented in all patients in the bupivacaine groups, and 21 of 30 in the plain fentanyl group. Baseline fetal heart rates did not change after injection in any group, and maternal blood pressure was unchanged.  相似文献   


20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号