首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A newly marketed rapid agglutination kit for the identification of Staphylococcus aureus, Slidex Staph Plus (bioMérieux), was compared to Staphaurex Plus (Murex Diagnostics) and Pastorex Staph-Plus (Sanofi Diagnostics Pasteur). The study took place in three clinical microbiology laboratories in three different European countries. A total of 892 staphylococcal isolates, including 278 methicillin-sensitive S. aureus (MSSA) isolates, 171 methicillin-resistant S. aureus (MRSA) isolates, and 443 coagulase-negative staphylococcal isolates, were analyzed. The sensitivities (MSSA/MRSA) and specificities, respectively, were 98. 2% (98.9%/97.1%) and 98.9% for Slidex Staph Plus, 98.2% (98.2%/98. 2%) and 96.2% for Staphaurex Plus, and 98.7% (98.6%/98.8%) and 95.7% for Pastorex Staph Plus. The specificity of the Slidex Staph Plus kit was statistically significantly higher than the specificities of Staphaurex Plus and Pastorex Staph-Plus. The Slidex Staph Plus is a very reliable test for the identification of S. aureus.  相似文献   

2.
Six commercial agglutination tests designed for the identification of Staphylococcus aureus were compared by using a strain collection which included 512 staphylococci representing 33 species (318 isolates of Staphylococcus aureus [including 144 oxacillin resistant], 46 S. epidermidis isolates, 15 S. haemolyticus isolates, 12 S. saprophyticus isolates, 29 S. schleiferi isolates, 30 S. lugdunensis isolates, and 62 other coagulase-negative staphylococci). This group also included a proportion of strains with unusual phenotypes (e.g., 19 coagulase-negative S. aureus isolates, 26 clumping factor-negative S. aureus isolates, and 4 S. aureus isolates each with a double deficiency). The overall sensitivity for identification of typical and atypical S. aureus was high with the Staphaurex Plus test (Murex Biotech) (99.7%), the Pastorex Staph Plus test (Sanofi Diagnostics Pasteur) (99.7%), and the Slidex Staph Plus test (bioMérieux) (100%). The overall rate of specificity was affected by the unusual inclusion in this study of a high proportion of non-S. aureus species, such as S. lugdunensis and S. schleiferi, which express a clumping factor and therefore produce a positive result with the agglutination tests.  相似文献   

3.
The performance of a second-generation rapid agglutination kit, Slidex Staph Plus (SSP; bioMérieux), was compared to those of the Slidex Staph (SS; bioMérieux), Staphaurex (SRX; Murex Diagnostics), and BBL Staphyloslide (BBL; Becton Dickinson) kits by using 508 clinical isolates composed of 150 methicillin-sensitive Staphylococcus aureus (MSSA) organisms, 154 methicillin-resistant S. aureus (MRSA) organisms, and 204 non-S. aureus Staphylococcus spp. Of the 508 isolates tested, 75% were fresh clinical isolates, with the remainder taken from five different freezer collections. All four agglutination tests had comparable sensitivities for MSSA and MRSA. However, the SS kit was significantly less specific (93.1%) than the three other tests (P > 0.05, McNemar test). These results demonstrate that the new rapid latex agglutination kit, SSP, was more specific for the identification of S. aureus than the previous version and performed comparably to the SRX and BBL kits.  相似文献   

4.
Various commercially produced agglutination kits are widely used for the identification of Staphylococcus aureus. These kits detect the presence of protein A and/or clumping factor on S. aureus. The literature has shown that methicillin-resistant S. aureus (MRSA) isolates which are deficient in both clumping factor and protein A may be misidentified. Two products, Slidex and Staphaurex Plus, utilize specific anti-S. aureus antibodies, potentially giving them greater sensitivity compared to products without these antibodies. We report a prospective study designed to compare the performance characteristics of Fastaph, Slidex, Staphaurex, Staphaurex Plus, Staphyloslide, and the tube coagulase test for the identification of staphylococcal isolates. All discrepant isolates were tested with the Gen-Probe AccuProbe S. aureus test and were identified to the species level with conventional reference biochemicals. A total of 1,193 isolates were tested, including 33 MRSA and 423 methicillin-sensitive S. aureus isolates. The sensitivities and specificities of the tests, respectively, were as follows: Fastaph, 99.1 and 98.9%; Slidex, 99.6 and 96.4%; Staphaurex, 98.9 and 99.9%; Staphaurex Plus, 99.6 and 93.9%; Staphyloslide, 99.1 and 98.9%; and tube coagulase, 99.3 and 100%. Sensitivity was excellent for all of the products tested. The specificities of Fastaph, Staphaurex, and Staphyloslide were excellent, while Staphaurex Plus and Slidex demonstrated less optimal results.  相似文献   

5.
Four commercially available slide agglutination systems for identifying Staphylococcus aureus were compared with the conventional slide (clumping factor) and tube coagulase tests. The systems evaluated included Bacto Staph Latex (Difco Laboratories, Detroit, Mich.), Staphyloslide (BBL Microbiology Systems, Cockeysville, Md.), Mini ID Accu-Staph (Carr-Scarborough Microbiologicals, Inc., Decatur, Ga.), and Staphaurex (Wellcome Diagnostics, Research Triangle Park, N.C.). A total of 338 clinical isolates, including methicillin-resistant S. aureus (n = 149), methicillin-susceptible S. aureus (n = 78), methicillin-resistant, coagulase-negative staphylococci (n = 45), and methicillin-susceptible, coagulase-negative staphylococci (n = 66), were tested by each method. The slide test for clumping factor, the 4-h tube coagulase test, Bacto Staph Latex, Staphyloslide, Mini ID Accu-Staph, and Staphaurex detected 212 (93.4%), 218 (96%), 223 (98.2%), 223 (98.2%), 221 (97.4%), and 224 (98.7%) of the S. aureus (44% methicillin-resistant) isolates, respectively. There were no false-positive results with any of the methods when the 111 strains of coagulase-negative staphylococci were tested. The results of this evaluation suggest that the four slide identification methods tested can provide rapid and accurate identification of methicillin-resistant S. aureus strains.  相似文献   

6.
 In this study, we evaluated a fourth-generation agglutination assay (Staph Plus; DiaMondiaL[DML]) for the rapid identification of Staphylococcus aureus. First, comparison with three third-generation assays (Slidex Staph Plus, bioMérieux; Staphaurex Plus, Murex Diagnostics; Pastorex Staph-Plus, Sanofi Diagnostics Pasteur) was performed on a predefined strain collection: 265 coagulase-negative staphylococci (CNS), 266 methicillin-resistant S. aureus (MRSA) and 262 methicillin-susceptible S. aureus (MSSA) strains (“strain study”). Second, patient material-derived strains (883 CNS, 847 MSSA and 135 MRSA) were tested concurrently with both the DML and Slidex assays (“daily practice study”). In the strain study, the overall sensitivity and specificity of the DML, Slidex, Staphaurex and Pastorex assays were 99.2% and 100%, 98.1% and 100%, 95.2% and 100%, and 98.2% and 98.8%, respectively. Using the respective tests, the result was indeterminate in 0.0%, 0.6%, 0.4% and 1.5% of the strains. Overall, the sensitivity of the DML and Slidex assays were comparable in both sub-studies. However, in MRSA strains, the sensitivity of the DML assay was significantly lower than the Slidex assay. The specificity of the Slidex assay was significantly higher than the DML assay. However, the percentage of indeterminate results was much higher for the Slidex than the DML assay. In conclusion, the presumptive identification of S. aureus by the DML assay proved to be equal to third-generation latex agglutination assays.  相似文献   

7.
Active surveillance for methicillin-resistant Staphylococcus aureus (MRSA) is among the strategies recommended by the Society for Healthcare Epidemiology of America for control of nosocomial MRSA infections. Infection control and laboratory personnel desire rapid, sensitive, and inexpensive methods to enhance surveillance activities. A multicenter study was performed to evaluate a new selective and differential chromogenic medium, BBL CHROMagar MRSA (C-MRSA) medium (BD Diagnostics, Sparks, MD), which enables recovery and concomitant identification of MRSA strains directly from nasal swab specimens taken from the anterior nares. Specimens were inoculated to C-MRSA and Trypticase soy agar with 5% sheep blood agar (TSA II, BD Diagnostics). Mauve colonies on C-MRSA at 24 h and 48 h and suspicious colonies on TSA II were confirmed as Staphylococcus aureus by Gram stain morphology and a coagulase test. In addition, the results of C-MRSA were compared to results of susceptibility testing (five different methods) of S. aureus strains isolated on TSA II. A total of 2,015 specimens were inoculated to C-MRSA and TSA II. Three hundred fifty-four S. aureus isolates were recovered; 208 (59%) were oxacillin (methicillin) susceptible and 146 (41%) were oxacillin resistant (MRSA). On C-MRSA, 139/146 or 95.2% of MRSA isolates were recovered, whereas recovery on TSA II was 86.9% (127/146) (P = 0.0027). The overall specificity of C-MRSA was 99.7%. When C-MRSA was compared to each susceptibility testing method, the sensitivity and specificity, respectively, were as follows: oxacillin MIC by broth microdilution, 94.4% and 96.7%; oxacillin screen agar, 94.3% and 96.7%; PBP2' latex agglutination, 93.7% and 98.5%; cefoxitin disk diffusion, 95.0% and 98.1%; and mecA PCR, 95.1% and 98.1%. In this study, C-MRSA was superior to TSA II for recovery of MRSA from surveillance specimens obtained from the anterior nares and was comparable to conventional, rapid, and molecular susceptibility methods for the identification of MRSA isolates.  相似文献   

8.
AIMS: To evaluate the BBL Crystal MRSA ID System for detection of oxacillin resistance in Staphylococcus aureus. METHODS: 52 methicillin resistant S aureus (MRSA) from five different countries and 85 methicillin susceptible S aureus (MSSA) were included. The species was confirmed by tube coagulation and detection of the clumping factor using the Staphaurex Plus. Clonal non-identity of the MRSA isolates was shown by pulsed field gel electrophoresis. MIC values (oxacillin) were determined using the Etest. Polymerase chain reaction was carried out to detect the mecA gene. The BBL Crystal MRSA ID System was carried out according to the manufacturer's instructions. RESULTS: The BBL Crystal MRSA ID System showed fluorescence in 45 of 52 MRSA (sensitivity 86.5%; negative predicitive value 92.2%), and the specificity was 97.6% (positive predicitive value 95.7%). Two of seven MRSA that failed to show fluorescence had MIC values (oxacillin) of 4 mg/litre. CONCLUSIONS: The BBL Crystal MRSA ID System is a valuable test for detecting oxacillin resistance in S aureus. Its major advantage is the short time (4-5 hours) required to perform the test when organisms are grown on tryptic soy agar or sheep blood agar. Difficulties may arise in borderline resistant isolates.  相似文献   

9.
Commercial latex agglutination tests (LATs) for the simultaneous detection of clumping factor and protein A are gaining increased acceptance as a means of identifying Staphylococcus aureus. We evaluated two LATs (Accu-Staph; Carr-Scarborough, Decatur, Ga.; Staphaurex; Wellcome, Dartford, England) with particular emphasis on their ability to correctly identify oxacillin-resistant S. aureus. We tested 59 oxacillin-resistant S. aureus, 136 oxacillin-susceptible S. aureus, and 92 coagulase-negative staphylococcal strains with the two LATs and with thermonuclease, slide clumping factor, tube coagulase, and protein A hemagglutination tests. Clumping factor and protein A were present in 96.9 and 82.1% of our S. aureus strains, respectively. Accu-Staph correctly identified 92.8% and Staphaurex correctly identified 91.3% of S. aureus strains. No significant difference in LAT positivity rates, presence of clumping factor, or presence of protein A was found between oxacillin-resistant and -susceptible S. aureus. Overall, there were 31 false-negative LATs for 20 S. aureus strains, 14 with Accu-Staph and 17 with Staphaurex. Ninety-five percent of these strains possessed either clumping factor or protein A or both when these factors were determined independently. There were five false-positive LATs for four strains of coagulase-negative staphylococci (three Staphylococcus epidermidis and one Staphylococcus warneri), four with Accu-Staph and one with Staphaurex. Clumping factor was present in one S. warneri strain. Thus, the specificities of Accu-Staph, Staphaurex, and the clumping factor test were 95.6, 98.9, and 98.9%, respectively. Our results indicated that LATs identify oxacillin-resistant and -susceptible S. aureus equally well; however, they offer no greater sensitivity or specificity than the clumping factor test for identification of S. aureus.  相似文献   

10.
The rapid detection of Staphylococcus aureus bacteremia and a swift determination of methicillin susceptibility has serious clinical implications affecting patient mortality. This study evaluated the StaphSR assay (BD GeneOhm, San Diego, CA), a real-time PCR assay, for the identification and differentiation of methicillin-susceptible S. aureus (MSSA) and methicillin-resistant S. aureus (MRSA) from 300 positive blood cultures. The BD GeneOhm StaphSR assay was performed and interpreted according to the manufacturer's recommendations. Positive blood cultures (containing predominantly gram-positive cocci in clusters) were subcultured on 5% sheep blood agar plates. After 18 to 24 h of incubation, isolates morphologically consistent with S. aureus were presumptively identified by latex agglutination (Staphaurex Plus; Remel, Lenexa, KS). Susceptibility testing was initially performed with the Phoenix automated microbiology system (BD Diagnostics, Sparks, MD). Additional susceptibility testing of samples with discrepant results was done using BBL oxacillin screen agar (BD Diagnostics, Sparks, MD), oxacillin and cefoxitin Etests (AB Biodisk, Solna, Sweden) on Mueller-Hinton agar, an immunoassay for penicillin binding protein 2' (Denka Seiken Co., Tokyo, Japan), and mecA PCR. The sensitivity, specificity, and positive and negative predictive values of the BD GeneOhm StaphSR assay for MSSA detection were 98.9, 96.7, 93.6, and 99.5%, respectively. For the detection of MRSA, the BD GeneOhm StaphSR assay was 100% sensitive and 98.4% specific; positive and negative predictive values for MRSA detection were 92.6 and 100%, respectively. Inhibition was seen with only one sample, and the issue was resolved upon retesting. The BD GeneOhm StaphSR assay appears to be a valuable diagnostic tool for quickly differentiating bacteremia caused by MSSA and MRSA from that caused by other gram-positive cocci.  相似文献   

11.
The speciation of methicillin-resistant Staphylococcus aureus (MRSA) poses a significant diagnostic problem when rapid identification methods such as slide agglutination tests, are used, because of the high proportion of false-negative reactions. 150 perfectly identified MRSA strains were tested on 5 commonly used agglutination reagents ("Bacto staph latex test", "Monostaph", "Pastorex staph", "Staphaurex", and "Staphyslide test") in comparison with a new micromethod ("RAPIDEC staph") which detects a type of staphylocoagulase within 2 hours by a fluorescence test. The "RAPIDEC staph" reagent enabled identification of all the MRSA while the agglutination tests gave poorer results: "Monostaph" correctly identified 64.6% of strains, "Staphyslide", 59.3%, "Bacto staph latex test", 44.6%, "Pastorex staph", 38.6% and "Staphaurex", 28.6%. These results show that agglutination slide tests are not reliable enough for the identification of MRSA which are more and more encountered in hospital wards. The authors recommend not to use slide agglutination methods. They suggest the tube test for coagulase which is the reference technique, although it is time-consuming and not well standardized. The results of this evaluation encourage the use of the "RAPIDEC staph" reagent since it is an easy-to-use, reliable technique for the rapid identification of Staphylococcus aureus.  相似文献   

12.
Five groups of strains of Staphylococcus aureus (54 in total) were tested by slide and tube coagulase methods with rabbit and human plasma, and the results were compared with a latex test for both clumping factor and Protein A (Staphaurex, Wellcome Foundation). The five groups comprised: epidemic methicillin resistant S aureus (group 1); other methicillin resistant S aureus (group 2); other resistant S aureus (group 3); other S aureus (group 4); and a group of reference strains, not all true S aureus (group 5). Groups 1, 3, and 4 gave consistently strong positive results with the tube test and the latex test and less strong positive results with the slide test. Group 2 strains sometimes gave weak or negative results in slide and latex tests, but tube tests with both types of plasma were strongly positive. Only within group 5 strains were negative results in the tube test found. Group 1 strains showed no diminution in expression of free coagulase or of clumping factor. The latex test was more sensitive than the slide test but less sensitive than the tube test. Doubtful or negative slide test or latex test results, particularly with strains resistant to methicillin, should be checked by a tube coagulase test.  相似文献   

13.
To improve efficiency in detecting nasal methicillin-resistant Staphylococcus aureus (MRSA), we evaluated a multiplex PCR using pre-enrichment of the specimen in selective broths, and compared it with detection performed by routine tests in hospital laboratories. Nasal swab specimens from 311 patients were inoculated onto mannitol-salt agar (MSA) at the hospital laboratories and in two Mueller-Hinton broths with 7% NaCl containing oxacillin at concentrations of 2 and 4 micro g/ml. Isolates on MSA were identified as MRSA by classical laboratory tests (coagulase and oxacillin disk diffusion tests). Oxacillin broth cultures were subcultured on blood agar and MRSA isolates were identified by coagulase and susceptibility tests, including agar dilution and the oxacillin-screening method (gold standard method). Simultaneously, multiplex-PCR was performed from the selective broths to detect S. aureus species-specific and mecA gene segments (OxMPCR method). Thirty-two S. aureus isolates were recovered: 29 (90.6%) were MRSA strains and 3 (9.4%) were oxacillin-susceptible isolates. Twenty-eight (96.5%) MRSA isolates were detected by OxMPCR, while 17 (58.6%) were identified by routine tests (P=0.002). This new method for detection of MRSA nasal carriers showed higher sensitivity and led to faster reporting--i.e., within 24 h--of results.  相似文献   

14.
The probe-based Velogene Rapid MRSA Identification Assay (ID Biomedical Corp., Vancouver, British Columbia, Canada) and the latex agglutination MRSA-Screen (Denka Seiken Co., Tokyo, Japan) were evaluated for their ability to identify methicillin-resistant Staphylococcus aureus (MRSA) and to distinguish strains of MRSA from borderline oxacillin-resistant S. aureus (BORSA; mecA-negative, oxacillin MICs of 2 to 8 microgram/ml). The Velogene is a 90-min assay using a chimeric probe to detect the mecA gene. MRSA-Screen is a 15-min latex agglutination test with penicillin-binding protein 2a antibody-sensitized latex particles. We compared these assays with the BBL Crystal MRSA ID System (Becton Dickinson, Cockeysville, Md.) and with PCR for mecA gene detection. A total of 397 clinical isolates of S. aureus were tested, consisting of 164 methicillin-susceptible strains, 197 MRSA strains, and 37 BORSA strains. All assays performed well for the identification of MRSA with sensitivities and specificities for Velogene, MRSA-Screen, and BBL Crystal MRSA ID of 98.5 and 100%, 98.5 and 100%, and 98.5 and 98%, respectively. Three MRSA strains were not correctly identified by each of the Velogene and MRSA-Screen assays, but repeat testing with a larger inoculum resolved the discrepancies. The BBL Crystal MRSA ID test misclassified four BORSA strains as MRSA. Both the Velogene and the MRSA-Screen assays are easy to perform, can accurately differentiate BORSA isolates from MRSA isolates, and provide a rapid alternative for the detection of methicillin resistance in S. aureus in clinical laboratories, especially when mecA PCR gene detection is unavailable.  相似文献   

15.
The MRSA screen test (Denka Seiken Co., Ltd.), a commercially available, rapid (20-min) slide latex agglutination test for the determination of methicillin resistance by detection of PBP 2a in Staphylococcus aureus, was compared with the oxacillin agar screen test and PCR detection of the mecA gene. A total of 563 S. aureus isolates were tested. Two hundred ninety-six of the isolates were methicillin-susceptible isolates from cultures of blood from consecutive patients. Also, 267 methicillin-resistant isolates that comprised 248 different phage types were tested. Methicillin resistance was defined as the presence of the mecA gene. Of the 267 mecA gene-positive isolates, 263 were positive by the MRSA screen test (sensitivity, 98.5%), and all the mecA-gene negative strains were negative by the MRSA screen test (specificity, 100%). The oxacillin agar screen test detected methicillin resistance in 250 of the mecA gene-positive isolates (sensitivity, 93.6%). The sensitivity of the MRSA screen test was statistically significantly higher than the sensitivity of the oxacillin agar screen test (P < 0. 05). The MRSA screen test is a highly sensitive and specific test for the detection of methicillin resistance. Also, it offers results within half an hour and is easy to perform, which makes this test a valuable tool in the ongoing battle against methicillin-resistant S. aureus.  相似文献   

16.
Multiplex polymerase chain reaction (PCR) strategy is described for rapid identification of clinically relevant methicillin resistant Staphylococcus aureus (MRSA) that targets mecA and coagulase genes. In this study, 150 staphylococcal clinical isolates were used that included 40 isolates of MRSA, 55 isolates of methicillin susceptible S. aureus (MSSA), 44 isolates of methicillin susceptible coagulase negative Staphylococcus spp. (MS-CoNS) and 11 isolates of methicillin resistant coagulase negative Staphylococcus spp. (MR-CoNS). Out of 55 S. aureus strains, three strains demonstrated mecA gene, which appeared to be oxacillin sensitive by disc diffusion. When (MS-CoNS) were evaluated, 10 isolates classified as oxacillin sensitive phenotypically, yielded positive results in PCR method. The results for mecA detection by PCR were more consistent with disk susceptibility tests in case of MRSA (100%) and MSSA (95%) isolates. In contrast to above results with MRSA and MSSA, mecA detection by PCR in MS-CoNS showed less correlation with disk susceptibility tests (77%). The results for coag detection by PCR were consistent with phenotypic tests in all isolates.  相似文献   

17.
The identification of Staphylococcus aureus directly from blood cultures is clinically relevant, but it requires a test that is both rapid and reliable. Previously, biochemical, immunological, tube coagulase, and thermostable-endonuclease methods have shown variable sensitivity and specificity. Testing directly from blood culture broth has not been described for the latex kit Staphaurex Plus (Murex Diagnostics Ltd.), and the modified conventional tests have not been used with the newer, continuously monitored blood culture systems. In addition, the commercial RAPIDEC staph kit (bioMerieux Vitek, Inc.) has been used to detect S. aureus directly from the Vital blood culture system (bioMerieux, Marcy l’Etoile, France), but its performance has not been evaluated with other continuously monitored systems. A total of 201 clinical blood cultures (BACTEC 9240 culture system; Johnston Laboratories, Inc.) in which a Gram stain showed gram-positive cocci resembling staphylococci were evaluated prospectively. The Staphaurex Plus kit, the tube coagulase test, the thermostable-endonuclease test, and the RAPIDEC staph kit were compared. The sensitivities were 23, 92, 85, and 98% and the specificities were 99, 100, 93, and 100%, respectively. The RAPIDEC staph kit was the most reliable test, with a diagnostic accuracy comparable to that of the best published results for any of the rapid tests. However, it was the most expensive of the tests and relatively labor-intensive. The tube coagulase test was also sensitive, the simplest to perform, and inexpensive.  相似文献   

18.
Twenty-three nasal swab samples that tested positive for methicillin-resistant Staphylococcus aureus (MRSA) on initial testing by the BD GeneOhm MRSA assay (BD-MRSA PCR; BD GeneOhm, San Diego, CA) were culture positive only for methicillin-susceptible S. aureus (MSSA) from an enrichment broth. The 23 recovered isolates were confirmed as MSSA by a variety of phenotypic methods, including the BD Phoenix automated microbiology system (BD Diagnostics, Sparks, MD), oxacillin screening agar (BD Diagnostics), BBL CHROMagar MRSA (BD Diagnostics), and a PBP2' assay (Denka Seiken Co., Tokyo, Japan); susceptibilities were determined by using Mueller-Hinton agar with oxacillin. All were positive by nuc PCR, specific for S. aureus, but negative for mecA with one exception. Isolates were characterized by using multiplex PCR methodology to determine structural types and variants (SCCmec typing); additional PCRs were performed for the detection of the ccr and mec complexes, the junkyard regions as well as the Panton-Valentine leukocidin. Pulsed-field gel electrophoresis was used to determine clonality. One phenotypic MSSA isolate contained an intact SCCmec. Twelve MSSA isolates tested positive for MRSA by the BD-MRSA PCR because of amplification of the mec priming site flanking the SCC insertion point, although these isolates lacked mecA. The 10 remaining isolates were not MRSA and tested as MSSA by phenotypic and genotypic assays. In our patient population, diagnostic and surveillance testing and subsequent infection control practices may be impacted by the frequency of these excision events when using the BD-MRSA PCR for MRSA detection.  相似文献   

19.

Background

Staphylococcus aureus is often responsible for fatal infections and recent upsurge of resistant strains has resulted in therapeutic failure. The identification of this microorganism is a major challenge to medical microbiologists in developing countries.

Methods

One hundred and eighty five isolates which had been previously isolated from the nares of 185 healthy college students'' volunteers in Amassoma, Bayelsa State, South Nigeria were identified by MALDI TOF mass spectrometry, and PCR amplification of the spa gene. The identified isolates were compared with presumptive identities obtained by growth on MSA, tube coagulation and slide agglutination tests. Antimicrobial susceptibility testing of S. aureus isolates was performed by Kirby Bauer technique while MRSA was screened for by growth on chromlDTM MRSA plate and confirmed by PCR-amplification of mecA/mecC genes.

Results

From the 185 staphylococci that grew with yellow colonies on MSA, 24 were positive in the slide coagulase test, while 17 were positive in the tube coagulase test; MALDI TOF mass spectrometry and PCR amplification of the spa gene showed excellent concordance with the tube test, as all tube coagulase-positive strains were identified as S. aureus, while tube coagulase-test negative isolates in all cases were designated as other staphylococcal species by MALDI-TOF mass spectrometry and were spa PCR test negative. All S. aureus isolates were susceptible to clindamycin, vancomycin, fusidic acid, rifampicin and linezolid, while observed resistance to penicillin and trimethoprim were high. Only one MRSA strain was detected

Conclusion

The study confirms that the tube coagulase test is an accurate diagnostic method for identification of S. aureus, while growths on MSA and slide agglutination tests are inaccurate. We found a low prevalence of MRSA and a high rate of trimethroprim-resistance in the studied population.  相似文献   

20.
Staphylococcus aureus isolates were screened for reduced susceptibility to glycopeptides with an initial glycopeptide agar screening test, followed by confirmation of the strains thus identified by two Etest strip techniques and population analysis. This procedure detected 48 methicillin-resistant S. aureus (MRSA) isolates with reduced susceptibility to glycopeptides from 24 patients among 883 MRSA isolates tested. The dissemination of a single clone was confirmed by pulsed-field gel electrophoresis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号