首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
We assessed the diagnostic performance of magnetic resonance (MR) arthrography in the diagnosis of articular-sided partial-thickness and full-thickness rotator cuff tears in a large symptomatic population. MR arthrograms obtained in 275 patients including a study group of 139 patients with rotator cuff tears proved by arthroscopy and a control group of 136 patients with arthroscopically intact rotator cuff tendons were reviewed in random order. MR imaging was performed on a 1.0 T system (Magnetom Expert, Siemens). MR arthrograms were analyzed by two radiologists in consensus for articular-sided partial-thickness and full-thickness tears of the supraspinatus, infraspinatus, and subscapularis tendons. At arthroscopy, 197 rotator cuff tears were diagnosed, including 105 partial-thickness (93 supraspinatus, nine infraspinatus, three subscapularis) and 92 full-thickness (43 supraspinatus, 20 infraspinatus, 29 subscapularis) tendon tears. For full-thickness tears, sensitivity, specificity, and accuracy were 96%, 99%, and 98%, respectively, and for partial tears 80%, 97%, and 95%, respectively. False negative and positive assessments in the diagnosis of articular-sided partial-thickness tears were predominantly [78% (35/45)] observed with small articular-sided (Ellman grade1) tendon tears. MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears and is accurate in the diagnosis of articular-sided partial-thickness tears. Limitations in the diagnosis of partial-thickness tears are mainly restricted to small articular-sided tears (Ellman grade 1) due to difficulties in differentiation between fiber tearing, tendinitis, synovitic changes, and superficial fraying at tendon margins.  相似文献   

2.
Purpose: To compare the diagnostic performance of multidetector computed tomographic (CT) arthrography and 1.5-T magnetic resonance (MR) arthrography in the evaluation of rotator cuff lesions, with arthroscopic correlation. Materials and Methods: This study was approved by the institutional ethical committee, and informed consent was obtained from all patients. CT and MR arthrographic images prospectively obtained in 56 consecutive patients, following the same arthrographic procedure, were independently evaluated by two radiologists. Arthroscopy, performed within 1 month of the imaging, was used as the reference standard. Sensitivity and specificity of CT and MR arthrography were compared by using the McNemar test. Interobserver and intertechnique agreement for detecting rotator cuff lesions were measured and compared with κ and Z statistics. The Bland-Altman method was used to determine interobserver and intertechnique agreement for measuring tendon tears. For grading fatty infiltration of rotator cuff muscles, κ and Z statistics were used. Results: There was no statistically significant difference in sensitivity and specificity between CT arthrography and MR arthrography in depiction of rotator cuff lesions. The respective sensitivity and specificity of CT arthrography were 92% and 93%-97% for the supraspinatus, 100% and 77%-79% for the infraspinatus, 75%-88% and 85%-90% for the subscapularis, and 55%-65% and 100% for the biceps tendon. The respective sensitivity and specificity of MR arthrography were 96% and 83%-93% for the supraspinatus, 88%-100% and 81%-83% for the infraspinatus, 75%-88% and 90%-100% for the subscapularis, and 65%-85% and 100% for the biceps tendon. Interobserver agreement was substantial to almost perfect (κ = 0.744-0.964 for CT arthrography; κ = 0.641-0.893 for MR arthrography), and intertechnique agreement was almost perfect (κ > 0.819). CT and MR arthrography both yielded moderate interobserver and intertechnique agreement for measuring rotator cuff tears and grading muscle fatty infiltration. Conclusion: Data suggest that CT and MR arthrography have similar diagnostic performance for the evaluation of rotator cuff tendon tears. ? RSNA, 2012.  相似文献   

3.
This article reviews the examination technique of shoulder ultrasound, normal and abnormal ultrasound findings in acute (posttraumatic) and chronic (degenerative) lesions. Moreover, it reviews the effectiveness of ultrasound in relation to magnetic resonance (MR) imaging. Most authors report that full-thickness tears of the supraspinatus can reliably be diagnosed by ultrasound. However, the simple diagnosis of a full-thickness rotator cuff tear is no longer sufficient for surgical management. The precise localization and size of rotator cuff tears as well as the extent of muscle degeneration is important for surgical planning. For this aspect and for partial-thickness tears of the supraspinatus, for subscapularis lesions as well as for lesions of the long biceps tendons there is no consensus regarding the diagnostic value of ultrasound. To the present, ultrasound (contrary to MR imaging) has failed to demonstrate that it consistently influences the clinician's degree of confidence in the clinical diagnosis or the treatment plan. Therefore, some orthopedic surgeons prefer MR imaging to ultrasound in the evaluation of rotator cuff tears and other abnormalities of the glenohumeral joint. Moreover, MR imaging, especially when combined with arthrography, represents a one-step investigation, which not only allows for assessment of rotator cuff lesion but also of lesions of the labrum (Bankart lesions, SLAP lesions), the joint capsule and the biceps tendon. It also demonstrates muscle atrophy, which represents an important predictor of surgical outcome in rotator cuff repair.  相似文献   

4.
The purpose of this study was to describe MR findings in full-thickness tears of the rotator cuff. Of 102 shoulders examined by MR imaging, 31 were found to have a full-thickness tendon tear at arthroscopy/bursoscopy (five shoulders) or open surgery (26 shoulders). All shoulders were imaged in oblique coronal and axial planes. MR images of the 102 shoulders were evaluated for (1) the presence of fluid in the subacromial and subdeltoid bursae; (2) abnormal signal of the supraspinatus, subscapularis, infraspinatus, and teres minor tendons; (3) interruption of tendon continuity and thinning of the tendon; and (4) proximal retraction of the junction of the muscle and tendon. The presence or absence of each finding was determined by consensus of two radiologists, who interpreted the images without knowledge of the surgical findings. Results in those 31 shoulders with proved full-thickness tears were: fluid in the subacromial bursae (29 shoulders), interruption of tendinous continuity (22 shoulders), focally increased signal of the tendon equivalent to that of water (27 shoulders), and musculotendinous retraction (24 shoulders). The finding of subacromial fluid was a sensitive indicator (93%) of a full-thickness tear, and interruption of tendinous continuity was a specific finding (96%) in diagnosing a full-thickness tear. Our experience shows interruption of tendon continuity is the most specific MR finding of full-thickness rotator cuff tears, while subacromial fluid is the most common finding.  相似文献   

5.
PURPOSE: The purpose of this work was to describe the MR appearance of tears of the subscapularis tendon and compare the usefulness of different imaging planes as well as note the association of subscapularis tears with other rotator cuff tears and biceps tendon dislocations. METHOD: MR studies at 1.5 T over an 8 year interval were retrospectively assessed for the presence of a rotator cuff tear and/or tear of the subscapularis tendon. Images that showed a subscapularis tear were reviewed for the presence of a visible tear separately on the axial, coronal, and sagittal images. The MR studies were also evaluated for associated tears of the supraspinatus, infraspinatus, and teres minor muscles as well as biceps tendon dislocation and the "naked humerus sign" on coronal images. Last, clinical records and surgical reports were reviewed. RESULTS: Forty-five (2%) of 2,167 rotator cuff tears involved the subscapularis; 27% were partial and 73% were complete tears. Tears were best seen in the sagittal oblique plane. Almost all subscapularis tears were an extension of typical rotator cuff tears: supraspinatus in 35 patients (79%), extending into infraspinatus tears in 25 (56%) and into teres minor tears in 2 patients (4%). Bicipital dislocations were seen in 22 patients (49%), and three complete tears of the biceps (7%) were noted as well. The naked humerus sign was demonstrated in 31 patients (69%). Surgical reports that confirmed the MR findings were available for 15 patients. CONCLUSION: About 2% of rotator cuff tears involve the subscapularis tendon. Most subscapularis tears are extensions of supraspinatus tears and frequently involve the biceps tendon.  相似文献   

6.

Objective

The objective of the study was to compare the diagnostic reliability of 3D US with MR arthrography in diagnosing supraspinatus tendon tears, with arthroscopic findings used as the standard.

Materials and methods

In a prospective study 50 patients who later underwent arthroscopic surgery of the rotator cuff were examined pre-operatively by 3D US with MR arthrography. The presence or absence of a full- or partial-thickness supraspinatus tendon tear and the tear size as demonstrated by each imaging and arthroscopy was recorded. The tear size was divided into three grades: small (<1 cm), medium (1-3 cm), and large (>3 cm).

Results

The arthroscopic diagnosis was a full-thickness tear in 40 patients, partial-thickness tears in 5, and intact supraspinatus tendon in 5. 3D US correctly diagnosed 35 out of 40 full-thickness tears and MR arthrography 39 out of 40 full-thickness tears. Regarding partial-thickness tears, 3D US underestimated 2 cases as no tear and overestimated 1 case as a full-thickness tear. MR arthrography underestimated 1 case as a partial-thickness tear and overestimated 2 cases as full-thickness and partial-thickness tears respectively. 3D US and MR arthrography yield a sensitivity for full-thickness tears of 87.5% and 97.5% with specificity of 90.0% and 90.0%. Based on the grading system, 3D US measurements correctly predicted the tear size of 23 (65.7%) of the 35 full-thickness tears and MR arthrography 30 (75.0%) of the 39 full-thickness tears.

Conclusion

Three-dimensional ultrasound seems to be a promising imaging modality comparable to MR arthrography for the assessment of the supraspinatus tendon tears.  相似文献   

7.
OBJECTIVE: We sought to compare the diagnostic accuracy of conventional MRI versus MR arthrography of the shoulder in the assessment of high-performance athletes (professional baseball players) and to compare our findings in these patients with the conventional MRI and MR arthrographic findings in an age-matched control group of nonprofessional athletes. MATERIALS AND METHODS: Conventional MRI and MR arthrographic examinations of the shoulder in 20 consecutive professional baseball players with shoulder pain were reviewed retrospectively by two musculoskeletal radiologists in consensus. These interpretations were compared with retrospective consensus interpretations of conventional MRI and MR arthrographic examinations of the shoulder obtained in a control group of 50 consecutive nonprofessional athletes with shoulder pain. MR images were assessed for full- or partial-thickness supraspinatus tendon tears, superior labral anteroposterior (SLAP) tears, and anterior or posterior labral tears. RESULTS: In the 20 consecutive professional athlete patients, two full-thickness and six partial-thickness undersurface supraspinatus tendon tears were seen on MR arthrography but not seen on conventional MRI as well as six SLAP tears, two anterior labral tears, and one posterior labral tear. Three patients had both SLAP tears and full- or partial-thickness supraspinatus tendon tears. Of 14 patients with findings on MR arthrography that were not seen on MRI, 11 had arthroscopic correlation. In all 11, arthroscopic findings confirmed findings on MR arthrography. In the group of 50 nonprofessional athlete patients, five had additional findings on MR arthrography not seen on conventional MRI: two anterior labral tears, two partial-thickness supraspinatus tendon tears, and two SLAP tears. One patient had both a partial-thickness supraspinatus tendon tear and a SLAP tear seen on MR arthrography. The five patients with additional findings on MR arthrography had arthroscopy. In all five, arthroscopic findings confirmed the findings on MR arthrography. CONCLUSION: MR arthrography is considerably more sensitive for detection of partial-thickness supraspinatus tears and labral tears than conventional MRI. MR arthrography showed injuries in addition to those seen on conventional MRI in 14 of 20 patients in the high-performance athlete group. These results suggest high-performance athletes may be a subgroup of patients for whom MR arthrography yields considerably more diagnostic information than conventional MRI.  相似文献   

8.
Pathology of the rotator cuff is the cause of most common problems at the shoulder joint. Acute injuries are not as frequent as chronic cuff disease, but often they aggravate inflammatory or degenerative tendon alterations, even if they are of minor severity. Traumatic rotator cuff tears predominantly affect the supraspinatus tendon or the rotator interval. The subscapularis tendon is involved in anterior dislocations of the glenohumeral joint or in direct trauma. Plain film radiography still remains the base of all further imaging studies. If only full-thickness tears must be ruled out, double-contrast arthrography and ultrasound are acceptable imaging modalities. However, the former has a drawback in being invasive and does not detect partial tears at the bursal site of the cuff or rotator cuff tendinopathy, whereas the latter heavily depends on the experience of the radiologist and is restricted to the rotator cuff. Nowadays the most comprehensive imaging method is magnetic resonance (MR) imaging. MR imaging enables the detection or exclusion of complete rotator cuff tears with a reasonable accuracy and is also suitable to diagnose further pathologies of the shoulder joint. MR arthrography is valuable in the detection of subtle anatomic details and further improves the differentiation of rotator cuff diseases. Although in comparison MR imaging is still the most expensive imaging method, its high negative predictive value for the diagnosis of complete rotator cuff tears and its reliability evaluating different shoulder joint pathologies make it the preferred imaging modality.  相似文献   

9.
The rotator cuff is loaded under static as well as dynamic conditions. Whilst the static properties of the rotator cuff muscle-tendon junctions have been reported, the dynamic mechanical behaviour has not. This study reports the dynamic mechanical properties with varying abduction angles in a human cadaver rotator cuff. No significant effect was found with varying the angle of testing or in the presence of a tear in the tendon. The supraspinatus was found to be the stiffest of the rotator cuff tendons followed by the subscapularis and infraspinatus.  相似文献   

10.
Jung JY  Jee WH  Park MY  Lee SY  Kim YS 《Skeletal radiology》2012,41(11):1401-1410

Objective

To assess the diagnostic performance of shoulder MR arthrography with 3D isotropic fat-suppressed (FS) turbo spin-echo sequence (TSE-SPACE) for supraspinatus tendon tears in comparison with 2D conventional sequences at 3.0?T.

Materials and methods

The study was HIPAA-compliant and approved by the institutional review board with a waiver of informed consent. Eighty-seven arthroscopically confirmed patients who underwent 3.0?T shoulder MR arthrography with 2D sequences and 3D TSE-SPACE were included in a consecutive fashion from March 2009 to February 2010. Two reviewers independently analyzed 2D sequences and 3D TSE-SPACE. Sensitivity, specificity, accuracy, and interobserver agreement (κ) were compared between 2D sequences and 3D TSE-SPACE for full-thickness and partial-thickness supraspinatus tendon tears together and for partial-thickness supraspinatus tendon tears alone.

Results

There were 33 full-thickness tears and 28 partial-thickness tears of supraspinatus tendons. For full-thickness and partial-thickness supraspinatus tendon tears together, the mean sensitivity, specificity, and accuracy of both readers were 96, 92, and 94% on 2D sequences and 91, 84, and 89% on 3D TSE-SPACE. For partial-thickness supraspinatus tendon tears alone, the mean sensitivity, specificity, and accuracy were 95, 92, and 94% on 2D sequences and 84, 85, and 84% on 3D TSE-SPACE. There was no statistical difference between 2D sequences and 3D TSE-SPACE. Interobserver agreements were almost perfect on 2D conventional sequences and substantial on 3D TSE-SPACE.

Conclusion

Compared with 2D conventional sequences, MR arthrography using 3D TSE-SPACE was comparable for diagnosing supraspinatus tendon tears despite limitations in detecting small partial-thickness tears and in discriminating between full-thickness and deep partial-thickness tears.  相似文献   

11.
S A Mirowitz 《Radiology》1991,180(3):735-740
The signal intensity and morphologic characteristics of the rotator cuff and surrounding structures at magnetic resonance (MR) imaging were investigated with five pulse sequences in 15 asymptomatic subjects. In all subjects, a focal region of relative increased signal intensity corresponding to the critical zone was observed in the supraspinatus tendon just proximal to its insertion. Soft-tissue signal intensity (isointense with muscle) was also located between the supraspinatus tendon and underlying joint capsule, interposed between the conjoined leaves of the supraspinatus and infraspinatus tendons, and superolateral to the conjoined cuff tendon, near its insertion. These regions were most conspicuous and most clearly defined with fat-suppression imaging. Small amounts of fluid were observed within the joint space and its recesses, the bicipital tendon sheath, and the subacromial-subdeltoid bursa. These and other MR imaging findings of this study previously have been regarded as indicative of rotator cuff abnormalities. These results will help refine the criteria for diagnosis of rotator cuff disorders with MR imaging.  相似文献   

12.
肩关节损伤的MR影像诊断   总被引:1,自引:0,他引:1  
目的 探讨常规MRI和MR间接关节造影对肩关节损伤的诊断价值.方法 回顾分析经关节镜证实的90例肩关节损伤患者肩关节常规MRI和MR问接关节造影表现,其中肩袖病变组57例、盂肱关节不稳组33例.对常规MRI和MR间接关节造影诊断结果进行Fisher确切概率法比较.结果 (1)肩袖病变组中MR间接关节造影37例,显示部分撕裂10例,1例漏诊;显示完全撕裂17例,2例误诊,7例肩袖无撕裂.MR间接关节造影显示部分撕裂的敏感度、特异度、准确度分别为90.9%(10/11)、92.3%(24/26)、91.9%(34/37);显示完全撕裂的敏感度、特异度、准确度分别为89.5%(17/19)、94.4%(17/18)、91.9%(34/37).MR间接关节造影诊断肩袖部分及完全撕裂的敏感度及准确度均高于常规MRI(P<0.05).(2)盂肱关节不稳组中,盂唇损伤26例,Hill-sachs病变27例、反Hill-sachs病变2例、骨陛Bankart损伤7例、关节囊损伤18例.间接关节造影20例,显示盂唇损伤14例,1例漏诊,5例正常.MR间接关节造影显示盂唇损伤的敏感度、特异度、准确度分别为93.3%(14/15)、100.0%(5/5)、95.0%(19/20).前者诊断盂唇损伤的敏感度及准确度明显高于常规MRI(P<0.05).结论 MR检查特别是MR间接关节造影能够准确显示肩关节常见病变及相关组织的病理发展过程,为临床诊断及治疗提供影像学依据.  相似文献   

13.
PURPOSE: To evaluate the effect of MR arthrography of the shoulder on diagnostic thinking and therapeutic decisions by orthopedic shoulder surgeons. MATERIAL AND METHODS: Orthopedic surgeons completed a questionnaire before and after MR arthrography for 73 consecutive patients. The main indications were suspected rotator cuff abnormalities. The clinical diagnosis, the degree of confidence in this diagnosis, and the therapeutic decision were noted before and after MR imaging. Surgical reports were available for 34 patients. RESULTS: Thirty-four percent of the pre-MR imaging diagnoses were withdrawn after MR imaging, and new diagnoses were made after MR imaging in 13% of the cases. Confidence in the diagnosis increased significantly after MR imaging for supraspinatus and infraspinatus lesions (p<0.05). Changes of therapeutic decision after MR imaging were noted in 36 of the 73 patients (49%). In 23 patients, more invasive therapeutic procedures were initiated after MR imaging, and a more conservative treatment was implemented for 13 patients. Agreement of MR diagnoses with surgery was 94% for supraspinatus tears, 87% for infraspinatus tears, 77% for subscapularis tears, and 81% for biceps tendon lesions. Agreement of clinical diagnoses with surgery was 56%, 83%, 50%, and 64%, respectively. CONCLUSION: MR arthrography of the shoulder has a major effect on diagnostic thinking and therapeutic decisions by orthopedic shoulder surgeons.  相似文献   

14.
PURPOSE: To prospectively evaluate rotator cuff contact with the glenoid in healthy volunteers placed in the unloaded and loaded abduction and external rotation (ABER) positions in an open magnetic resonance (MR) imager. MATERIALS AND METHODS: The study was institutional review board approved and HIPAA compliant, and informed consent was received. Eight male volunteers with no history of shoulder pain or pathology were imaged in a 0.5-T open MR imager. Volunteers were imaged in an unloaded ABER position with the arm at 90 degrees abduction and in a loaded ABER position, with a 1-kg load that produced an average external rotation of 111 degrees+/-6 (standard deviation). Two radiologists graded rotator cuff contact on a three-point scale. Three-dimensional anatomic models generated from the MR images were used to measure distances. Minimum distances were computed between the tendon insertion sites and the glenoid, acromion, and coracoid for the loaded ABER position. Minimum distances were compared by using a paired Student t test. RESULTS: In the unloaded ABER position, contact was seen between the infraspinatus and supraspinatus tendons and the glenoid in all eight volunteers. In the loaded ABER position, contact was also observed between the infraspinatus and supraspinatus and the posterior and posterosuperior glenoid, respectively. Deformation of the infraspinatus on the glenoid was seen in four volunteers, whereas supraspinatus deformation was only seen in one volunteer. The minimum distance between the supraspinatus insertion and acromion in the loaded ABER position decreased significantly (P<.01). Supraspinatus tendon to glenoid and infraspinatus tendon to glenoid minimum distances also decreased significantly (P<.01). CONCLUSION: The unloaded and loaded ABER positions resulted in contact of the supraspinatus and infraspinatus with the glenoid in all volunteers. Distances between the rotator cuff insertion sites and the glenoid decreased in the loaded ABER position.  相似文献   

15.
BACKGROUND: Restoring the anatomical footprint may improve the healing and mechanical strength of repaired tendons. A double row of suture anchors increases the tendon-bone contact area, reconstituting a more anatomical configuration of the rotator cuff footprint. HYPOTHESIS: There is no difference in clinical and imaging outcome between single-row and double-row suture anchor technique repairs of rotator cuff tears. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: The authors recruited 60 patients. In 30 patients, rotator cuff repair was performed with a single-row suture anchor technique (group 1). In the other 30 patients, rotator cuff repair was performed with a double-row suture anchor technique (group 2). RESULTS: Eight patients (4 in the single-row anchor repair group and 4 in the double-row anchor repair group) did not return at the final follow-up. At the 2-year follow-up, no statistically significant differences were seen with respect to the University of California, Los Angeles score and range of motion values. At 2-year follow-up, postoperative magnetic resonance arthrography in group 1 showed intact tendons in 14 patients, partial-thickness defects in 10 patients, and full-thickness defects in 2 patients. In group 2, magnetic resonance arthrography showed an intact rotator cuff in 18 patients, partial-thickness defects in 7 patients, and full-thickness defects in 1 patient. CONCLUSION: Single- and double-row techniques provide comparable clinical outcome at 2 years. A double-row technique produces a mechanically superior construct compared with the single-row method in restoring the anatomical footprint of the rotator cuff, but these mechanical advantages do not translate into superior clinical performance.  相似文献   

16.
OBJECTIVE: This study assessed the utility of MRI in patients with new or persistent pain after surgery with bioabsorbable rotator cuff anchors. SUBJECTS AND METHODS. Three musculoskeletal radiologists prospectively reviewed MRIs of 30 patients with pain after rotator cuff repair with fixation by rotator cuff anchors. Each radiologist described the location of the rotator cuff anchors and whether the supraspinatus tendon was intact or not. MRI findings were correlated with second-look arthroscopy. Consensus MRI interpretations by the three radiologists were obtained retrospectively. RESULTS: Of the 30 patients, nine had dislodgement of the rotator cuff anchors from the humeral head along with a full-thickness supraspinatus tendon retear. The dislodged rotator cuff anchor position could be determined on coronal and sagittal MRIs, providing the orthopedic surgeon a preoperative map for tendon reattachment and retrieval of the dislodged rotator cuff anchor. Four patients had loose rotator cuff anchors but intact supraspinatus tendons. Three patients had supraspinatus tendon retears, but the rotator cuff anchors were intact. In all 16 patients, arthroscopic findings confirmed MRI findings. Fourteen patients had intact rotator cuff anchors and intact supraspinatus tendons on MRI. Of these 14 patients, five had second-look arthroscopy confirming MRI findings. CONCLUSION: MRI is useful in the assessment of patients with persistent or new-onset pain after supraspinatus tendon repair with rotator cuff anchors. MRI provides a presurgical map for second-look arthroscopy to assess retear of the supraspinatus tendon and also aids in retrieval of dislodged rotator cuff anchors.  相似文献   

17.
The purpose was to assess the diagnostic performance of MR arthrography to diagnose calcific tendinitis of the shoulder and to assess the reasons for diagnostic errors. Standard MR arthrograms of 22 patients with calcific tendinitis and 61 controls were retrospectively analyzed by two independent and blinded radiologists. All cases were consecutively collected from a database. Conventional radiographs were available in all cases serving as gold standard. The supraspinatus was involved in 16, the infraspinatus in four and the subscapularis in two patients. All diagnostic errors were analyzed by two additional readers. Reader 1 correctly detected 12 of the 22 shoulders with and 42 of the 61 shoulders without calcific tendinitis (sensitivity 0.55, specificity 0.66). The corresponding values for reader 2 were 13 of 22 and 40 of 61 cases (sensitivity 0.59, specificity 0.69). Inter-rater agreement (kappa-value) was 0.42. Small size of the calcific deposits and isointensity compared to the surrounding tissue were the most important reasons for false negative results. Normal hypointense areas within the supraspinatus tendon substance and attachment were the main reason for false positive results. In conclusion, MR arthrography is insufficient in the diagnosis of calcific tendinitis. Normal hypointense parts of the rotator cuff may mimic calcific deposits and calcifications may not be detected when they are isointense compared to the rotator cuff. Therefore, MR imaging should not be interpreted without corresponding radiographs.  相似文献   

18.
OBJECTIVE: Conventional radiography, arthrography, CT arthrography, and MR arthrography--including use of the abduction and external rotation position--were compared, with arthroscopic correlation, to determine the spectrum of abnormalities encountered and the relative benefits of each imaging method in the evaluation of shoulder lesions occurring in 17 throwing athletes. SUBJECTS AND METHODS: Each of 36 athletes with shoulder pain aggravated by abduction and external rotation was examined in a single visit during which conventional radiography, arthrography, CT arthrography, and MR arthrography were performed. In 17 of these athletes, imaging findings were compared with those at arthroscopy. All images were independently evaluated by two groups of musculoskeletal radiologists. RESULTS: Structures found to be affected were, in decreasing order of frequency, the following: the posterosuperior labrum, supraspinatus tendon, infraspinatus tendon, humeral head, glenoid cavity and rim, acromioclavicular joint, anteroinferior capsulolabral complex, biceps tendon, and subscapularis tendon. MR arthrography without and with abduction and external rotation yielded the highest sensitivity and specificity for all lesions with the exceptions of bone sclerosis and enthesophytes (which were best seen with CT arthrography). MR arthrography with abduction and external rotation was most accurate for diagnosis of rotator cuff and anteroinferior capsulolabral complex tears. CONCLUSION: On the basis of these preliminary results, we believe that MR arthrography with abduction and external rotation should be part of the imaging evaluation of shoulder pain in throwing athletes, owing to the high sensitivity of this imaging technique.  相似文献   

19.
Purpose To compare indirect magnetic resonance (MR) arthrography findings in patients with rotator cuff tears with and without symptoms. Materials and Methods Indirect MR arthrography results of 15 asymptomatic and 23 symptomatic rotator cuff tears were retrospectively reviewed, comparing the type and size of tears and amount of subacrominal-subdeltoid bursal fluid. Results There were 14 partial-thickness tears and one full-thickness tear in the asymptomatic group, with 4 small and 11 medium tears. In the symptomatic group, there were 16 partial-thickness and 7 full-thickness tears, with 14 small, 5medium, and 4 large tears. In the asymptomatic group, the amount of subacrominal-subdeltoid bursal fluid was grade 0, 6 patients; grade 1, 6 patients; grade 2, 2 patients; and grade 3, 1 patient. In the symptomatic group, the amount of subacrominal-subdeltoid bursal fluid was grade 0, 4 patients; grade 1, 3 patients; grade 2, 8 patients; and grade 3, 8 patients. We found no statistically significant difference between symptomatic and asymptomatic tears in the kind and size of tears, and in the amount of subacrominal-subdeltoid bursal fluid. Conclusion We found no difference in the MR findings between symptomatic and asymptomatic rotator cuff tears.  相似文献   

20.

Purpose

The role of apoptosis in the progression of rotator cuff tendinopathy remains poorly understood. In particular, the extent of apoptosis in the partially torn supraspinatus tendon has not been well examined.

Methods

Biopsies were obtained from nine partially torn supraspinatus tendons, from the matched intact subscapularis tendons, and from 10 reference subscapularis tendons. Immunohistochemistry was used to assess the density of apoptotic cells (activated caspase-3; Asp175), proliferation (Ki67), and p53 (M7001), a key protein involved in regulating cell death. The Bonar scale was used to evaluate tendon degeneration.

Results

The density of apoptotic tendon cells and the density of cells expressing p53 were significantly increased in both the partially torn supraspinatus tendons and in the matched subscapularis tendons, compared with uninjured reference tendons. The Bonar score revealed significant tendon degeneration in the partially torn supraspinatus tendons compared with both matched and reference subscapularis tendons. Tendon cell proliferation was significantly increased in the partially torn supraspinatus tendons compared with reference subscapularis tendons.

Conclusions

Partial-thickness tears of the supraspinatus tendon demonstrated an increased density of apoptotic, p53+ tendon cells. The fact that apoptosis was accompanied by increased tendon cell proliferation suggests that apoptosis may be related to an ongoing injury-repair process. Increased tenocyte apoptosis may be a relatively early feature in rotator cuff tendinopathy and could represent a possible target for therapeutic intervention.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号