首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 171 毫秒
1.
彩色多普勒超声引导斜角进针自动肾活检   总被引:1,自引:1,他引:0  
目的探讨彩色多普勒超声引导斜角进针自动穿刺枪在肾活检中的临床应用。方法对41例彩超引导下斜角进针巴德(BARD)穿刺枪肾活检和35例B超定位手动肾活检进行回顾性对比分析。结果DARD穿刺枪自动肾活检一次成功率97.56%,二次成功率100%,活检标本平均长度(13.1±3.51)mm,肾小球平均数目(15.5±6.5)个,肉眼血尿发生率为2.43%,肾包膜下血肿(≥2.0cm)为0,而B超定位手动法分别为85.71%,60%,(10.8±2.35)mm,(8.5±5.93)个,11.43%,2.86%,两组比较差异具有统计学意义。结论彩色多普勒超声引导活检枪法具有操作简便、成功率高、并发症少等优点,值得广泛推广。  相似文献   

2.
肾组织表皮生长因子含量改变在增生性肾炎中的意义   总被引:4,自引:0,他引:4  
目的 探讨表皮生长因子 (h EGF)在增生性肾小球肾炎 (PGN)发病中的作用 .方法 采用放射免疫分析法检测2 4例 PGN、12例非 PGN患者及 13例正常人血清、尿液和肾活检组织 h EGF含量 .结果  PGN组肾组织、尿 h EGF含量显著高于非 PGN组 (0 .6 3± 0 .18vs 0 .5 9± 0 .15 ,2 75± 5 1vs6 4± 19,P<0 .0 1)和正常对照组 (0 .6 3± 0 .18vs0 .5 4± 0 .14 ,2 75± 5 1vs5 4± 18,P<0 .0 1) ,PGN组血清 h EGF较非PGN和正常对照组均无显著差异 :肾组织 h EGF含量愈高 ,肾小球病理改变程度愈重 (r=0 .6 5 1,P<0 .0 1) ;尿 h EGF含量与肾组织 h EGF含量正相关 (r=0 .80 6 ,P<0 .0 0 1) .结论  h EGF可能与 PGN发病机制有关 ,尿 h EGF含量测定可反映肾组织局部 h EGF含量变化 .  相似文献   

3.
目的  1全面分析评价超声引导自动肾活检的临床意义。2客观评价自动肾活检成功率及其并发症。方法  1研究对象为北京医科大学第三临床医院 1991年 3月~ 1999年 1月 5 11例自动肾活检 (18G活检针 )的住院患者。1991年 1~ 3月 36例手动肾活检 (14G活检针 )住院患者。自动肾活检在超声引导下进行 ,而在手动活检中 ,超声主要用于肾脏的定位标记。2对自动和手动两种活检方法进行比较分析 ;并对自动肾活检的成功率及并发症进行单因素分析、分层分析及多因素非条件 L ogistic回归分析。结果  1自动活检组取材成功率 (91.0 0 % )显著高于手动活检组 (6 6 .6 7% ) (P<0 .0 1) ,而并发症的发生率明显少于手动组(P<0 .0 1)。 2取材长度和穿刺次数对自动肾活检的取材成功率未见有显著性影响 (P>0 .0 5 )。 3高血压 (舒张压≥ 95 mm Hg)、急性肾功不全、肾病综合征为影响并发症发生的独立因素。舒张压≥ 95 mm Hg、急性肾功不全的并发症发生率较高 ;肾病综合征的并发症发病率较低。急性肾功不全同时伴有高血压对并发症的发生似有相加作用。45 11例自动肾活检患者术后帮助临床进一步明确诊断 42 .0 4% ,修正诊断 7.2 7% ,改变治疗方案 10 .2 2 %。结论  1实时超声引导自动肾活检是一种安全可靠的方法。2在满足病  相似文献   

4.
移植肾穿刺活检在肾移植术后的临床应用   总被引:7,自引:0,他引:7  
目的 :探讨移植肾活检在肾移植术后的临床应用价值 .方法 :3 4 (男 2 8,女 6)例均为同种异体肾移植患者 ,平均年龄 3 4 6岁 (18~ 5 2岁 ) ,其中 2 0例术后尿素氮和肌酐正常 ,10例临床诊断为急性排斥反应 ,4例为肾功能延迟恢复 .分别在彩色B超 (2 6例 )和CT引导 (8例 )下行移植肾活检 .结果 :3 4例患者共行穿刺 3 7人次 .一次穿刺成功率为 :B超 89% ,CT 10 0 % .2例术后出现轻度肉眼血尿 ,余无其他并发症 .B超组 (n =2 9)与CT组 (n =8)比较 ,肾小球数 :(13 9± 3 2 )vs(11 1± 4 7) ;动脉数 :(2 6± 0 7)vs (2 1± 1 1) ;不合格标本 :3 (10 3 % )vs 0 ;穿刺时间 :(1.0± 0 5 )minvs(5 0± 1 0 )min(P <0 .0 1) .根据Banff97分类 :肾功正常组 (n =2 0 )中 18例为正常 ,2例为临界改变 .临床诊断为急性排斥反应 (n =10 ) ,急性排斥反应为 7例 ,其中IA2例 ,ⅡA 3例 ,ⅡB 1例 ,Ⅲ 1例 .2例为环孢素A中毒 ,1例为急性肾小管坏死 .肾功能延迟恢复组 (n =4 )中 2例为急性肾小管坏死 ,1例为环孢素A中毒 ,1例为急性肾小管坏死合并急性排斥反应 .临床诊断正确率为 73 5 % .结论 :移植肾穿刺活检能够及时准确地对肾移植术后肾功能异常者进行诊断和疗效判断 .CT介导移植肾活检的穿刺标本质量优于B超  相似文献   

5.
超声引导下自动肾活检应用体会   总被引:2,自引:1,他引:1  
自动活检枪 (简称 ABD)超声引导自动活检( USGAB)方法对取出的肾组织可进行光镜病理 ,免疫荧光及电镜检查。因此 ,它对肾实质性病变的诊断、临床分型、治疗及预后的判断有重要价值。我科自 1 998年开展此项工作 ,并对 72例慢性肾脏疾病人成功的开展了此项工作 ,现将体会报道如下。1 临床资料1 .1 一般资料 :1 998年 5月至 2 0 0 0年 6月 ,我们共对 72例肾脏疾病患者开展超声引导下自动肾活检术 ,均为我院肾内科住院病人 ,72例患者经临床和实验室检查均符合肾活检适应症而需要进行组织学诊断者。其中男 44例 ,女 2 8例 ;年龄 1 6~ 60…  相似文献   

6.
目的 :分析 18G ,16G和 14G穿刺针肾活检的安全性及其对明确肾脏病理诊断的意义。方法 :在实时超声显像的引导下应用自动活检枪对 10 0 6例患者行肾穿刺活检 ,并就穿刺所获取的肾小球数目、穿刺后的病理诊断和并发症的情况进行分析。结果 :14G和 16G穿刺针所获取的肾小球均高于 18G(P <0 .0 1) ;穿刺产生血尿和血肿等并发症比较 ,3组间差异无显著性 (P >0 .0 5 )。结论 :14G ,16G与 18G 3种直径的活检针对肾活检均安全 ,大直径穿刺针能获得更多的肾小球 ,更利于临床诊断。  相似文献   

7.
目的 :探讨超声引导自动活检甲状腺诊断甲状腺微小癌的临床意义。方法 :采用ATL30 0 0型彩色多普勒超声仪、美国产 BAND保险式自动活检枪、1 8G槽式组织切割针 ,对 2 5例甲状腺小结节患者进行超声引导下自动活检。结果 :取材成功率 1 0 0 %,活检病理诊断符合率为92 .8%,其中乳头状癌 9例 ,滤泡状癌 2例 ,未分化癌 1例 ,髓样癌 1例。结论 :超声引导自动活检甲状腺是诊断甲状腺微小癌的一种可靠方法 ,对甲状腺小结节性质的鉴别诊断有较大应用价值  相似文献   

8.
Li H  Zhang H  Wang HY 《中华医学杂志》2003,83(8):684-687
目的 探讨肾脏特异性表达新基因Collectrin在大鼠 5 / 6肾切除残余肾组织中的表达变化 ,为Collectrin基因功能研究提供线索。方法 建立慢性肾衰大鼠 5 / 6肾切除模型 ,分为对照组( 10只 )、手术组 ( 12只 )和依那普利治疗组 ( 12只 ) ,采用逆转录 PCR和Western蛋白印迹、免疫组织化学技术检测手术后 2、8和 16周大鼠肾组织Collectrin的表达变化。结果 在对照组中 ,随着大鼠周龄的增长大鼠CollectrinmRNA表达逐渐减少。 2 ,8,16周分别为 ,1 6 9± 0 0 9,1 38± 0 0 4,1 2 1± 0 0 9,(P <0 0 5 ) ;在术后 2 ,8,16周 ,手术组 ( 2 33± 0 0 7,1 85± 0 2 0 ,1 47± 0 17)Collectrin表达明显高于对照组 ( 1 6 9± 0 0 9,1 38± 0 0 4,1 2 1± 0 0 9,P <0 0 5 ) ;经依那普利治疗后 ,Collectrin表达明显减少 ;手术组Collectrin的表达在手术后 2周明显增加 ,随着慢性肾衰的进展Collectrin的表达逐渐减少。 2 ,8,16周分别为 2 33± 0 0 7,1 85± 0 2 0 ,1 47± 0 17(P <0 0 5 )。Collectrin蛋白的表达情况与CollectrinmRNA表达情况相一致。结论 Collectrin的表达随大鼠周龄的增长而减少 ;在 5 / 6肾切除残余肾组织中 ,Collectrin的表达与肾脏的增生、肥大的病生理变化相关。  相似文献   

9.
呼吸致肾解剖学改变对超声引导肾组织活检的影响   总被引:1,自引:0,他引:1  
目的 :研究呼吸致肾解剖学改变对超声引导肾组织活检的影响 ,旨在提高穿刺成功率 ,降低并发症。方法 :将 12 0例有肾穿刺适应证的患者随机分成 3组。A组 (法 ) 4 0例 ,根据深吸气后肾脏移动的个体差异来确定穿刺进针角度。B组 (法 ) 4 0例 ,超声定位于肾下极外侧斜角进针。C组 (法 ) 4 0例 ,超声定位于肾下极外侧与皮肤垂直进针。结果 :A B C 3种方法中A法穿刺成功率最高 (97 5 % ) ,每厘米肾组织中肾小球数最多 (16 2 4± 8 2 1) ,并发症最少 (7 5 % ) ,B法次之 ,C法最低 ,且A法与B法及C法相比均具有显著性差异。结论 :肾随呼吸移动有其普遍性 (上下位移 ) ,但存在着较大的个体差异 (内旋、外旋及向腹侧位移 ) ,根据肾移动的个体差异决定进针方向及角度 ,可防止空穿、误穿 ,明显提高穿刺成功率、降低并发症。  相似文献   

10.
目的:探讨超声引导下经皮肾组织活检术对弥漫性肾病的诊断价值。方法:对18例尿化验异常而超声图象无特异性改变患者行超声引导下肾组织活检。结果:所有患者均获得病理学诊断。结论:超声下肾自动活检是诊断弥漫性肾病的重要方法。  相似文献   

11.
BackgroundRenal biopsy has a definite role in the management of pediatric kidney diseases. Most centers have given up the earlier practice of performing blind biopsy using Tru-Cut needle and started doing real time ultrasound-guided renal biopsy with an automated spring-loaded gun, which has become standard of care in the last decade or so.MethodsWe performed a cross-sectional analysis of the pediatric biopsies conducted at our center over the years by both methods to evaluate whether ultrasound-guided renal biopsy with a disposable automated spring-loaded gun was superior to blind biopsy with a disposable needle of the same size in terms of reduction of complications and improving the yield. We also reviewed the indications and the histopathological diagnosis of pediatric renal biopsies at our center.ResultsA total of 45 native kidney biopsies were performed blind and 48 ultrasound-guided biopsies using the curvilinear probe (frequency 3-5 Hz) of GE Logiq P3 ultrasound machine with disposable spring-loaded automated guns. There was a significant increase in the yield of biopsy in terms of the number of glomeruli per pass. A significant increase in the mean number of glomeruli was noted when a biopsy was performed under ultrasound guidance (P < 0.0001). Gross hematuria was significantly reduced as compared to the earlier biopsies done blind i.e., without ultrasound (P ¼ 0.03). Nephrotic syndrome was the commonest indication for biopsy in our patients during both time periods studied. The most common histopathological diagnosis was MesPGN among the children who underwent kidney biopsy from 2005 to 2007, while Minimal Change Disease (MCD) and Focal Segmental Glomerulosclerosis (FSGS) were most frequently reported.ConclusionUltrasound guided kidney biopsies in pediatric age group have significant reduction in incidence of post gross hematuria and significant increase in the mean number of glomeruli per pass.  相似文献   

12.
目的探讨比较超声引导下经皮肾活检术与超声定位后经皮盲穿法肾活检术在临床应用中的优越性。方法将我院肾脏内科收治的100例肾脏病患者,在彩超引导下行肾活检术,分成A组;同期广元市医院收治的100例肾脏病患者,在彩超定位后使用"十"字盲穿法行肾活检术,分成B组。观察分析两组其成功率及并发症。结果 A组患者一针成功取材92例,二针成功取材96例,成功率分别为92%、96%;B组一针成功取材63例,二针成功取材82例,失败2例,成功率分别为63%、82%。A组并发症发生率6%;B组并发症发生率23%。结论用BARD MAGNUM自动穿刺枪经皮超声引导下行肾活检术相比超声定位后经皮盲穿法肾活检术并发症少,风险小,成功率高。  相似文献   

13.
目的:探讨超声引导微创经皮肾镜取石术与肾窦内肾盂切开取石术治疗肾结石疗效的对比及安全性。方法:选取76例有手术指征的肾结石患者,按照入院先后顺序及其患者对手术术式的选择意愿分为研究组及对照组,各38例,对照组采取肾窦内肾盂切开取石术治疗,研究组采取超声引导微创经皮肾镜取石术治疗,观察两组治疗疗效及安全性。结果:(1)两组患者术前Cr、βMG、eGFR、RBP比较差异无统计学意义(P>0.05),术后对照组分别为(102.38±18.34)μmol/L、(83.23±32.25)mL/min/1.73m2、(3.13±1.42)ng/L、(64.42±33.42)mg/L,研究组分别为(103.68±17.59)μmol/L、(84.17±30.65)mL/min/1.73m2、(3.15±1.38)ng/L、(62.82±32.15)mg/L,两组治疗前后组内比较差异无统计学意义(P>0.05),治疗后各指标在组间比较差异无统计学意义(P>0.05),结石清除率、残留率对照组分别为84.21%(32/38)、15.79%(6/38),研究组分别为89.47%(34/38)、10.53%(4/38),两组比较无显著性差异(P>0.05)。(2)不良反应及并发症:无1例发生损失周围脏器情况,对照组术后2例患者出血量达到400mL以上,给予输血治疗,7例患者发生术后高热(对照组5例,研究组2例),后证实存在感染,经过合理抗感染治疗后恢复正常。结论:超声引导微创经皮肾镜取石术治疗肾结石较肾窦内肾盂切开取石术创伤小、术后恢复快、结石清除率高,使用安全,并发症少。  相似文献   

14.
目的 探讨超声引导下经皮肾穿刺活检的成功率及并发症。方法 应用自动活装置 ,在普通超声探头的引导下对 2 0 3例肾脏疾病患者进行经皮肾穿刺活检。结果 成功率 97% ,肉眼血尿发生率 4.0 %。结论 此方法操作简便、成功率高且并发症少。  相似文献   

15.
目的评价经后腹腔镜联合经腰小切口及超声辅助下行中心型肾癌保留肾单位手术的临床疗效,总结手术经验。方法回顾性分析2010年8月至2012年3月12例经后腹腔镜联合经腰小切口及超声辅助下行保留肾单位手术治疗中心型肾癌患者的临床资料。男9例、女3例,平均年龄(56.2±2.8)岁;肿瘤平均直径(2.2±1.4)cm。术前均经超声、CT、MRI或CT动脉造影检查。患者全身麻醉后取健侧卧位,后腹腔镜常规方法游离出肾动脉、肾静脉及肾脏,切开腋后线与腋前线的两个Trocar之间的皮肤及肌肉,建立小切口,将超声探头从小切口置于肾表面,对肿瘤进行定位并标记手术切缘,放置冰屑于肾周,行肾动脉阻断或动、静脉阻断下保留肾单位手术。结果 12例手术均获成功,手术平均时间(124.5±5.8)min,术中平均热缺血时间(26.3±8.6)min,术中平均出血量(65.8±21.6)mL。切缘阴性率100%,平均手术切口(8.8±2.4)cm,术后平均住院时间(12.4±2.6)d;术后无并发症发生。随访平均(13.6±7.4)个月,未见肿瘤复发及转移。结论后腹腔镜联合经腰小切口及超声辅助下对中心型肾癌行保留肾单位手术具有创伤小、出血少、热缺血时间短、恢复快的优点,是一种安全、有效的治疗方法,具有良好的临床应用前景。  相似文献   

16.
Background Various rat kidney transplantation models have been introduced over the decades and the study on the models seems to lack novelty and necessity.However,vascular anastomosis,especially renal vein,is still very difficult for trainees.The aim of this study was to provide the modified renal venous anastomosis of rat kidney transplantation to substitute the currant method for trainees.Methods Male Wistar rats were used as donors and recipients,respectively.Left orthotopic transplantation was performed with a modified technique of renal vein anastomosis,combining the end-to-end sutures with epidural catheter.Meanwhile,the survival rate,warm ischemia time,renal venous anastomosis time,and complications were recorded to evaluate the merits of the modified technique compared with the current recommended technique of rat renal vein.Two trainees took part in the learning of the models in two methods for performing 30 operations,respectively.Results The difference in warm ischemia time (from (57.25±7.30) minutes in the first 10 operations to (30.05±1.85)minutes in the third 10 operations) and renal vein anastomosis time (from (32.80±3.80) minutes in the first 10 operations to (19.30±0.98) minutes in the third 10 operations) was significantly short (P<0.01) and the survival rate was statistically high (from (25±7)% in the first 10 operations to 70% in the third 10 operations) in equal number of operations (P<0.01) by comparing with the current recommended method ((47.60±7.19) minutes to (22.8±1.85) minutes,(22.40±3.10) minutes to (9.95±1.50) minutes,45%±7% to 80%±0,respectively).The intraoperative complications and postoperative complications of renal venous anastomosis were also significantly decreased (P<0.01).Conclusions The technique with epidural catheter can shorten the learning curve of the trainee learning rat kidney transplantation.It may replace the currently recommended technique of rat renal vein for trainees.  相似文献   

17.
王可  邹翰琴  叶江 《西部医学》2013,(11):1721-1722,1725
目的 探讨超声引导经皮肾脏穿刺组织活检的注意事项及对肾脏疾病的临床应用价值.方法 对320例肾脏疾病患者在超声引导经皮肾脏穿刺组织活检的成功率、不良反应及临床应用价值进行分析与评价.结果 320例肾脏活检取材670条,取材成功率99.0%,均能达到临床病理检查要求,在穿刺初期有4例出现血肿,穿刺后有16例肉眼血尿,总并发症发生率为6.3%,均无明显感染、大出血、肾周脏器损害等严重并发症发生.结论 超声引导经皮肾脏穿刺组织活检对了解肾脏疾病的病理类型,指导临床治疗及判断疾病预后有重要意义,超声引导是穿刺成功的关键.  相似文献   