首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cementing with a gun and proximal pressurisation. Clinical outcome was assessed using the Harris Hip score. Radiological analysis was performed on calibrated plain radiographs taken in two planes. Complete radiological data on 110 patients (120 hips) and clinical follow-up on all the surviving 111 patients (122 hips) was available. The fate of all the hips was known. At final follow-up, the mean Harris Hip score was 86 (47 to 100), and 87 of 116 patients (75%) had good or excellent scores. Survival with revision of the stem for aseptic loosening as the endpoint was 100%; and survival with revision of the stem for any reason was 95.9% (95% confidence interval 87.8 to 96.8) at ten years. All the stems subsided vertically at the stem-cement interface in a predictable pattern, at an overall mean rate of 0.18 mm per year (0.02 to 2.16), but with a mean rate of 0.80 mm (0.02 to 2.5) during the first year. The mean total subsidence was 1.95 mm (0.21 to 24). Only three stems loosened at the cement-bone interface. There was excellent preservation of proximal femoral bone stock. There was a high incidence of Brooker III and IV heterotopic ossification affecting 25 patients (22%). The collarless polished tapered stem has an excellent clinical and radiological outcome at a minimum of ten years' follow-up. The pattern and magnitude of subsidence of the stem within the cement mantle occurred in a predictable pattern, consistent with the design philosophy.  相似文献   

2.
目的 探讨应用锥形沟槽设计的股骨组配柄假体行全髋关节股骨侧假体翻修术的中期疗效.方法 2000年5月至2005年8月采用锥形沟槽式股骨组配柄假体行全髋关节翻修术19例,男6例,女13例;年龄47~86岁,平均67岁.单髋17例,双髋2例.术前诊断均为股骨柄和臼杯假体无菌性松动合并股骨侧骨缺损,按Paprosky标准诊断为Ⅱ型缺损4髋,Ⅲa型缺损14髋,Ⅲb型缺损3髋.股骨侧翻修均采用锥形沟槽式股骨组配柄假体(Lima-Lto,意大利),髋臼侧均采用SPH臼杯假体(LimaLto,意大利)行生物学固定.关节头臼界面采用陶瓷-陶瓷组合17髋,金属-聚乙烯组合4髋.结果 全部病例随访5~10年,平均7年.Harris髋关节评分由术前平均(46.2±15.2)分改善至翻修术后半年平均(90.3±5.3)分,末次随访平均(92.2±3.5)分.X线片显示翻修柄获广泛骨长入骨性固定者20髋(95%,20/21),纤维性稳定者1髋(5%,1/21).假体下沉0~10 mm,平均2.4 mm.随访期间无一例因假体松动或其他原因需行再次翻修.结论 采用锥形沟槽式股骨组配柄假体行伴有PaproskyⅡ型、Ⅲa和Ⅲb型骨缺损的股骨侧假体翻修术,可获得理想的初始稳定和永久生物学固定,中期随访疗效满意.
Abstract:
Objective To evaluate the midterm results of the revision total hip replacement with a fluted and tapered modular stem. Methods Nineteen patients (21 hips) underwent revision total hip arthroplasty from May 2000 to August 2005 were reviewed. There were 13 females and 6 males, with an average age of 67 years. Pre-revision diagnosis included aseptic loosening of the cups and stems associated with femoral defects (Paprosky classification) type Ⅱ 4 hips (19%), type Ⅲa 14 hips (67%), and type Ⅲb 3 hips (14%). The adopted acetabular component was SPH (Lima-Lto, Italy), and femoral component was a fluted and tapered modular stem (Lima-Lto, Italy). Clinical and radiographic evaluations were performed postoperatively. Results The mean follow-up was 7 years (range, 5-10). The Harris hip score improved from 46.2±15.2 preoperatively to 90.3±5.3 postoperatively, and maintain 92.2±3.5 at the latest follow-up. The X-ray films showed bone ingrowths fixation in 20 hips (95%) and fibrous stable fixation in 1 hip (5%). The average stem subsidence was 2.4 mm (range, 0-10 mm). There were no re-revisions of the femoral stem for any reason. Conclusion The midterm results of revision total hip replacement with a fluted and tapered modular stem in Paprosky type Ⅱ, Ⅲ a, Ⅲ b femoral defect associated aseptic loosening of the femoral stem was encouraging.  相似文献   

3.
We have reviewed 70 Harris-Galante uncemented acetabular components implanted as hybrid hip replacements with cemented stems between 1991 and 1995 in 53 patients whose mean age was 40 years (19 to 49). The mean follow-up was for 13.6 years (12 to 16) with no loss to follow-up. We assessed the patients both clinically and radiologically. The mean Oxford hip score was 20 (12 to 46) and the mean Harris hip score 81 (37 to 100) at the final review. Radiologically, 27 hips (39%) had femoral osteolysis, 13 (19%) acetabular osteolysis, and 31 (44%) radiolucent lines around the acetabular component. Kaplan-Meier survival curves were constructed for the outcomes of revision of the acetabular component, revision of the component and polyethylene liner, and impending revision for progressive osteolysis. The cumulative survival for revision of the acetabular component was 94% (95% confidence interval 88.4 to 99.7), for the component and liner 84% (95% confidence interval 74.5 to 93.5) and for impending revision 55.3% (95% confidence interval 40.6 to 70) at 16 years. Uncemented acetabular components with polyethylene liners undergo silent lysis and merit regular long-term radiological review.  相似文献   

4.
BACKGROUND: We report the results of cementless total hip arthroplasty with a tapered, rectangular titanium stem that was introduced in 1979 and continues to be used today with only minor changes. The aim of the design is to achieve primary stability to resist rotational and axial forces through precision rasping and press-fit implantation of a tapered, rectangular femoral component. METHODS: Between October 1986 and November 1987, 208 total hip arthroplasties with insertion of a tapered, rectangular titanium stem and a threaded cup without cement were performed in 200 consecutive patients (average age, sixty-one years; range, twenty-two to eighty-four years). RESULTS: At the time of the latest follow-up, fifty-one patients (fifty-two hips) had died and sixteen patients had been lost to follow-up, leaving 133 patients. Twelve hips had been revised, two in patients who subsequently died, leaving 123 living patients without revision. The median follow-up time was 120.7 months. Five cups needed revision surgery because of aseptic loosening; two, because of massive polyethylene wear; one, because of posttraumatic migration; and one, because of breakage. Three femoral stems were revised: one because of malpositioning (the reoperation was done five days after implantation); one, because of infection; and the third, after multiple failed acetabular revisions. The mean Harris hip score for the patients who did not have revision was 85.4 points (range, 46 to 100 points) at the time of the latest follow-up. Four patients (3%) complained of thigh pain that was not associated with another disorder. According to the criteria of Engh et al., all femoral implants were graded as stable bone-ingrown. The probability of survival of both the femoral and the acetabular component at ten years, with any revision as the end point, was 0.92 (95% confidence interval, 0.88 to 0.97). The probability of survival of the cup was 0.93 (95% confidence interval, 0.89 to 0.97), and that of the stem was 0.99 (95% confidence interval, 0.97 to 1.00). CONCLUSIONS: The results of arthroplasty with a tapered, rectangular titanium stem combined with a conical threaded cup inserted without cement were excellent at a minimum of ten years. Our data suggest that femoral stem fixation continues to be secure, while the threaded cup is prone to aseptic loosening.  相似文献   

5.
Revision after failed femoral components may be technically demanding due to loss of peri-prosthetic bone. This retrospective study evaluated the long-term results of femoral revision using the cementless Wagner Self-Locking stem. Between 1992 and 1998, 68 consecutive hips in 66 patients underwent femoral revision using this implant. A total of 25 patients died from unrelated causes without further revision; the remaining 41 hips in 41 patients (12 men and 29 women) with a mean age of 61 years (29 to 80) were reviewed at a mean follow-up of 13.9 years (10.4 to 15.8). A transfemoral approach was used in 32 hips. A total of five stems required further revision because of infection in two, progressive subsidence in two and recurrent dislocation in one. Four hips had dislocated and eight stems had subsided ≥?10?mm. The mean Harris hip score improved from 33 points pre-operatively to 75 points at final follow-up (p < 0.001). In all, 33 stems (91.7%) showed radiological signs of stable bone fixation. The cumulative survival rates at 15.8 years with femoral revision for any reason and for stem failure as the endpoints were 92.0% (95% confidence interval (CI) 86.0% to 98.4%) and 96.6% (95% CI 92.2% to 100%), respectively. The survivorship with revision and ≥ 10 mm migration of the stem as the endpoint was 83.6% (95% CI 76.6% to 91.4%). This study shows quite good survival and moderate clinical outcome when using a monoblock tapered titanium stem for supporting the regeneration of bone in complex revision hip surgery.  相似文献   

6.
We carried out a clinical and radiological review of 103 cementless primary hip arthroplasties with a tapered rectangular grit-blasted titanium press-fit femoral component and a threaded conical titanium acetabular component at a mean follow-up of 14.4 years (10.2 to 17.1). The mean Harris hip score at the last follow-up was 89.2 (32 to 100). No early loosening and no fracture of the implant were found. One patient needed revision surgery because of a late deep infection. In 11 hips (10.7%), the reason for revision was progressive wear of the polyethylene liner. Exchange of the acetabular component because of aseptic loosening without detectable liner wear was carried out in three hips (2.9%). After 15 years the survivorship with aseptic loosening as the definition for failure was 95.6% for the acetabular component and 100% for the femoral component.  相似文献   

7.
The aim of this study was to assess the clinical and radiological outcome of the cementless-system (CLS) femoral component designed by Spotorno with a taper design. Ninety-four patients (107 hips) were operated on from January 1987 to December 1988. The female/male ratio was 2/1, the mean age was 51 years (range 20–77 years). Clinical follow-up was obtained in 89 hips (83%). Five patients (7 hips, 6.5%) could not be traced. Nine patients (11 hips, 10%) had died before the minimum time of follow-up required for this study (10 years). All these hips still had their stem in place at the time of the last intermediate inquiry. The mean follow-up was 10.3 ± 0.3 years. No stem required revision. According to the Harris score, 84% of hips were rated good or excellent, 14% fair, and 2% poor. The average Harris hip score was 88 at the time of the last follow-up. Fifteen patients (17%) reported occasional thigh pain. All patients reported complete relief of pain within the first 6 months after the operation. Radiologically, 95% of stems showed stable fixation by bony ingrowth, 5% by fibrous ingrowth. Seven (9%) uncemented acetabular components showed progressive migration. Three of those cups had been replaced in the meantime. Fifty-one (65%) of the CLS stems induced either no change in femoral bone density or only patchy loss of bone density localized to zone 1 or 7 according to Gruen, while 27 (35%) of the hips showed some reduction of bone density in the proximal diaphysis of the femur (zone 2 or 6). Severe progressive osteolysis of the femoral cortex underneath the lesser trochanter was found in 4 hips (5%) with coexistent loosening of the cup. In all of these hips, the Mecron cup had been used. At a mean follow-up of 10 years, the results of the CLS femoral component are comparable with those of modern techniques of cementing in primary total hip arthroplasty and with the long-term outcomes of other uncemented stems with tapered design. The long-term fixation of the cup remains an unsolved problem. Received: 14 August 1999  相似文献   

8.
Ten-year survival of the MS-30 matt-surfaced cemented stem   总被引:1,自引:0,他引:1  
The Morscher-Spotorno (MS-30) femoral stem is a stainless-steel, straight, three-dimensionally tapered, collarless implant for cemented fixation in total hip replacement.We report the results at ten years of a consecutive series of 124 total hip replacements in 121 patients with the matt-surfaced MS-30 stem and an alumina ceramic head of 28-mm diameter. All the stems were fixed with Palacos bone cement with gentamicin using a modern cementing technique. They were combined with an uncemented, press-fit cup. The mean period of observation was 10.2 years (8.3 to 12.1) and no patient was lost to follow-up. Twenty-seven patients (22%) died with the implant in situ. Nine could only be interviewed by telephone. We included 85 patients with 88 hips in the clinical and radiological follow-up examinations.None of the stems or cups had been revised. The Harris hip score was excellent or good in 97% (85 hips) and moderate in 3% (three hips). Radiologically, six hips (6.8%) had osteolysis adjacent to the stem, mostly in Gruen zone 7. Twenty (22.7%) showed one or more radiolucent lines. Twenty-two stems (25%) had subsided by 2 mm to 5 mm. In these cases two showed osteolysis (9.1%) with subsidence and four without (6.1%). Radiolucent lines were seen in seven with migration (31.8%) and in 13 without (19.7%). No infections and no acetabular osteolysis were observed.The clinical results were excellent with survivorship after ten years of 100% and only a slightly statistically non-significant higher rate of osteolysis and radiolucency in cases of subsidence.  相似文献   

9.
AIM: To present the 18 year survival and the clinical and radiological outcomes of the Müller straight stem, cemented, total hip arthroplasty (THA).METHODS: Between 1989 and 2007, 176 primary total hip arthroplasties in 164 consecutive patients were performed in our institution by the senior author. All patients received a Müller cemented straight stem and a cemented polyethylene liner. The mean age of the patients was 62 years (45-78). The diagnosis was primary osteoarthritis in 151 hips, dysplasia of the hip in 12 and subcapital fracture of the femur in 13. Following discharge, serial follow-up consisted of clinical evaluation based on the Harris Hip Score and radiological assessment. The survival of the prosthesis using revision for any reason as an end-point was calculated by Kaplan-Meier analysis.RESULTS: Twenty-four (15%) patients died during the follow-up study, 6 (4%) patients were lost, while the remaining 134 patients (141 hips) were followed-up for a mean of 10 years (3-18 years). HSS score at the latest follow-up revealed that 84 hips (59.5%) had excellent results, 30 (22.2%) good, 11 (7.8%) fair and 9 (6.3%) poor. There were 3 acetabular revisions due to aseptic loosening. Six (4.2%) stems were diagnosed as having radiographic definitive loosening; however, only 1 was revised. 30% of the surviving stems showed no radiological changes of radiolucency, while 70% showed some changes. Survival of the prosthesis for any reason was 96% at 10 years and 81% at 18 years.CONCLUSION: The 18 year survival of the Müller straight stem, cemented THA is comparable to those of other successful cemented systems.  相似文献   

10.
BACKGROUND: There have been few reports on the mid- and long-term follow-up results of the proximally HA-coated femoral stem. We evaluated this type of stem prospectively, with 6-12 years of follow-up. METHODS: The survival rate, Harris hip score and radiographic features of 106 hips in 100 consecutive patients were evaluated. The mean age at operation was 51 years (SD 8.2). RESULTS: The mean Harris hip score at the time of the latest follow-up was 95 points. Spot welds occurred in 95% of the patients and were first observed at a mean follow-up of 1.4 years in one or more of the Gruen regions, corresponding to the coated part of the femoral stem. A higher grade of stress shielding correlated with a less favorable Harris hip score and pain subscore. According to the criteria of Engh, all stems were graded as stable and durable bone-ingrown. No femoral component was revised. INTERPRETATION: At an average follow-up of 8 years, this proximally HA-coated femoral component showed favorable clinical and radiological outcome and excellent survivorship.  相似文献   

11.
We previously evaluated ninety-eight consecutive patients (148 hips) at mean of 9.3 years after total hip arthroplasty; the mean age at the time of the index surgical procedure was 47.3 years. Fifty patients (100 hips) had simultaneous bilateral arthroplasty with a cemented stem in one hip and a cementless stem in the contralateral hip. Forty-eight patients (forty-eight hips) had unilateral hip arthroplasty with a cementless stem. All patients had a cementless acetabular component. In our first report, we found no difference in clinical results, as measured with the Harris hip score and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), between the cementless and cemented stems. One hip (2%) in the hybrid group (a cementless cup and a cemented stem) had revision because of infection and two hips (2%) in the fully cementless group had revision of the femoral component because of a periprosthetic fracture. Between the time of follow-up in that study (at a mean of 9.3 years) and the time of follow-up in the present study (at a mean of 17.3 years), twenty-two revisions of acetabular components were performed, with eight in the hybrid group and fourteen in the fully cementless group. There was no difference in clinical results, as measured with the Harris hip score and the WOMAC, between the hybrid and fully cementless groups. At the time of the present review, forty (83%) of forty-eight acetabular components in the hybrid group and eighty (85%) of ninety-four acetabular components in the fully cementless group were intact. Most of the femoral components (98%) in both groups were intact. Wear and periacetabular osteolysis were the causes of failure in the hips requiring revision.  相似文献   

12.
BACKGROUND: Acetabular bone deficiency can present a challenge during total hip arthroplasty, especially in young patients. The purpose of the present study was to evaluate the long-term clinical and radiographic outcomes of primary and revision acetabular reconstruction with use of an impaction bone-grafting technique and a cemented polyethylene cup in young patients who had preexisting acetabular bone deficiency. METHODS: Forty-two consecutive acetabular reconstructions were performed in thirty-seven patients who were younger than fifty years old (average, 37.2 years old). The impaction bone-grafting technique was used for twenty-three primary and nineteen revision acetabular reconstructions. Twenty-eight patients (thirty-one hips) were available for review after a minimum duration of follow-up of fifteen years. Clinical and radiographic results were assessed, and survivorship analysis was performed with the Kaplan-Meier method. RESULTS: Eight hips were revised at a mean of twelve years (range, three to twenty-one years) after a primary reconstruction (four hips) or revision reconstruction (four hips). The revision was performed because of aseptic loosening of the acetabular component in four hips and because of culture-proven septic loosening in two. Two additional cups (both in hips that had had a revision reconstruction) were revised, during revision of the femoral stem, because of wear (one hip) or because of persistent intraoperative instability (one hip). Twenty-eight hips (in twenty-five patients) had retention of the acetabular component for a minimum of fifteen years. The mean Harris hip score for that group was 89 points. Twenty-six of these twenty-eight hips had no or slight pain. Kaplan-Meier analysis revealed a twenty-year survival rate of 80% (95% confidence interval, 67% to 94%) with acetabular revision for any reason as the end point and of 91% (95% confidence interval, 80% to 100%) with acetabular revision because of aseptic loosening as the end point. CONCLUSIONS: Acetabular reconstruction with use of impaction bone-grafting and a cemented polyethylene cup is a reliable and durable technique that is associated with good long-term results in young patients with acetabular bone-stock defects.  相似文献   

13.
14.
We performed 114 consecutive primary total hip arthroplasties with a cementless expansion acetabular component in 101 patients for advanced osteonecrosis of the femoral head. The mean age of the patients at surgery was 51 years (36 to 62) and the mean length of follow-up was 110 months (84 to 129). The mean pre-operative Harris hip score of 47 points improved to 93 points at final follow-up. The polyethylene liner was exchanged in two hips during this period and one broken acetabular component was revised. The mean linear wear rate of polyethylene was 0.07 mm/year and peri-acetabular osteolysis was seen in two hips (1.9%). Kaplan-Meier analysis indicated that the survival of the acetabular component without revision was 97.8% (95% confidence interval 0.956 to 1.000) at ten years. Our study has shown that the results of THA with a cementless expansion acetabular component and an alumina-polyethylene bearing surface are good.  相似文献   

15.
We followed 48 consecutive patients (50 hips) with osteoarthritis who received a primary total hip replacement using a tapered stem with hydroxylapatite coating (Cerafit Multicone H-A.C.) and a press-fit cup. Mean follow-up was 3 years, mean patient age was 54.7 years, and mean preoperative Harris hip score was 57. Quantitative evaluation of periprosthetic bone remodelling was assessed 1 year after the index operation using computed tomography (CT). Clinical and radiological follow-up was obtained in all hips. The mean Harris hip score at follow-up was 96. Forty-nine hips were clinically rated good or excellent. No thigh pain was reported. Radiographs showed stable fixation by bone ingrowth in all hips. Fifteen hips were eligible for CT. Three years after operation, mean decrease of overall bone mineral density (BMD) was 14.2% and mean decrease of cortical BMD 15.5% in the metaphyseal portion. In the diaphyseal portion, mean decrease of overall BMD was 10.0% and mean decrease of cortical BMD 7.7%. Minimal changes were observed at the level of the tip of the stem. Clinical and radiological outcome using a tapered femoral stem with hydroxylapatite coating compares favourably with other reports. Osteodensitometry shows limited proximal femoral bone resorption.  相似文献   

16.
The uncemented Bi-Contact total hip arthroplasty   总被引:1,自引:0,他引:1  
We reviewed a consecutive series of 153 uncemented Bi-Contact (Aesculap, Tuttlingen, Germany) total hip arthroplasties (THAs) in 138 patients who had been followed for at least 5 years (mean, 6.8 years; range, 5-9 years). The Bi-Contact uncemented THA consists of a straight femoral stem made of titanium alloy. The proximal portion of the stem is titanium plasma-sprayed. The cup is press-fit with or without hydroxyapatite coating with a facility for anchoring screws with a snap-fit polyethylene liner. The mean age of the patients was 70.8 years (range, 41-94 years). The mean preoperative Harris hip score of 41 (range, 20-80) improved postoperatively to a mean of 92 (range, 56-96). Three acetabular cups were revised for aseptic loosening, and 1 cup was revised for recurrent dislocation. To date, none of the stems have been revised for aseptic loosening. Radiographic evaluation of the remaining 149 hips revealed that the acetabular cup was stable in 146 hips and possibly unstable in the remaining 3 cases with nonprogressive osteolysis behind the cup. None of the stems showed any evidence of instability. Using the recommendation of revision as the endpoint, the cumulative survival for the prosthesis was 97.3% at a mean follow-up of 6.8 years (95% confidence interval, 95.9-99.4), with stem survival of 100%. In the medium-term, these results are comparable to cemented primary THA and justify the continued use of this prosthesis.  相似文献   

17.
BACKGROUND: Recent studies have suggested that cemented femoral components with a polished surface may provide superior long-term fixation when compared with femoral components with a roughened surface. The purpose of this study was to evaluate the results of total hip arthroplasty with a cemented femoral component with a polished surface finish and compare them with the results of total hip arthroplasty performed with a similar design of cemented femoral component with a rougher surface finish. METHODS: We retrospectively reviewed a consecutive group of 132 patients (149 hips) in whom primary total hip arthroplasty had been performed by one surgeon using a cemented collared femoral component with a polished (0.1-microm Ra) surface finish and a cementless acetabular component. Ninety-eight patients (115 hips) were followed for a minimum of ten years. We compared the survivorship of this prosthesis with that of a femoral component of similar design but with rougher surfaces (matte or grit-blasted). RESULTS: No polished stems were revised because of aseptic loosening or demonstrated radiographic evidence of loosening; however, eight hips (5.4%) with a polished stem demonstrated osteolysis distal to the greater or lesser tro-chanter. In contrast, six stems (2.0%) with a matte surface finish of 0.8-microm Ra were revised because of aseptic loosening, and an additional five stems were seen to be loose radiographically. Eleven stems (9.2%) with a grit-blasted surface finish of 2.1-microm Ra were revised because of aseptic loosening, and an additional four stems were seen to be loose radiographically. The difference in the prevalence of revision due to aseptic loosening between the group with the 0.1-microm Ra surface and the group with the 2.1-microm Ra surface was significant (p = 0.001), as was the difference between the prevalence of revision due to aseptic loosening between the group with the 0.8-microm Ra surface and the group with the 2.1-microm Ra surface (p = 0.001). No cups were revised because of aseptic loosening, and one hip had radiographic signs of acetabular loosening. CONCLUSIONS: This study demonstrated excellent durability of a prosthesis consisting of a cemented, collared, polished femoral component and a cementless acetabular component. While no hips were revised because of aseptic loosening, distal femoral osteolysis was observed in eight hips (5.4%), a higher prevalence than has been reported by others after similar durations of follow-up of tapered, collarless, polished femoral components.  相似文献   

18.
BACKGROUND: Revision of a total hip arthroplasty in a patient who has had congenital hip dysplasia or dislocation is often more difficult than a standard revision operation. The purpose of this study was to assess the efficacy and complications of use of a cementless hemispherical acetabular component for revision of an acetabular component of a failed total hip replacement in patients whose initial problem was arthritis secondary to congenital dislocation or dysplasia. The mean duration of follow-up was approximately eight years. METHODS: We reviewed a consecutive series of sixty-one hips in fifty-three patients who underwent a cementless acetabular revision with use of a hemispherical acetabular component, with or without concurrent femoral revision. Data were collected prospectively. The mean age of the patients at the time of the index operation was fifty-six years. A mean of 1.9 ipsilateral hip operations had been performed previously. Thirty-nine hips (64 percent) had a so-called high hip center prior to the index revision. With one exception, the uncemented acetabular component was fixed with screws. Fifty-one acetabular components were placed with so-called line-to-line fit, and ten were oversized by one to three millimeters. In thirty-eight hips, the femoral component was revised as well. Twenty-nine femora were reconstructed with use of a cemented device, and nine were revised with an uncemented patch-porous-coated femoral stem (a stem on which the porous coating appears in patches). RESULTS: Four patients (five hips) died prior to the five-year minimum follow-up interval. With the exception of one hip treated with resection arthroplasty because of deep infection, none of the hips in these deceased patients had been revised or had a loose component. One living patient (one hip) had a resection arthroplasty, and one additional patient (two hips) had both stable acetabular components rerevised at the time of femoral rerevision at another institution because of loosening and osteolysis. One patient refused to return for follow-up, but the components had not been revised. The remaining fifty-two hips in forty-six patients were followed for a mean of 8.6 years (range, 5.0 to 12.7 years). The mean Harris hip score was 80 points (range, 56 to 100 points) at the time of the latest follow-up. No acetabular component had been revised, although two had migrated. No other acetabular component was loose according to our radiographic criteria. Thus, the mechanical failure rate on the acetabular side was 3 percent (two of sixty-one) for the entire series and 4 percent (two of fifty-two) for the patients who had been followed for a mean of 8.6 years. On the femoral side, the mechanical failure rate was 3 percent (one of twenty-nine) for the cemented stems and six of nine for the uncemented patch-porous-coated stems. CONCLUSIONS: Of the approaches used in this difficult series of patients requiring revision, the hybrid arthroplasty (a cementless acetabular component and a cemented femoral component) yielded overall good results after an intermediate duration of follow-up.  相似文献   

19.

Background

The risk of revision following primary total hip arthroplasty (THA) is increased in young patients who undergo THA for pathologies other than primary osteoarthritis. We report the results of primary THA performed with cemented polished stems in patients aged 40 years and younger for pathologies other than primary osteoarthritis.

Methods

We investigated 52 patients (65 hips) who underwent primary THA for secondary osteoarthritis with a cemented tapered polished stem between 1990 and 2007. Clinical and radiographic outcomes, available in 46 patients (57 hips), included the Harris Hip Scores, Societe Internationale de Chirurgie Orthopedique et de Traumatologie activity, patient satisfaction, stem survival and reoperations, and assessment of prosthesis-cement-bone radiolucencies, osteolysis, and femoral bone deficiencies.

Results

Median patient age was 34 years (16-40) and follow-up was 14 years (mean 13, range 5-22). Stem survival to the endpoint revision for loosening was 100% and to the endpoint revision for any reason, excluding infection was 88% (95% confidence interval 78-98) at 16 years. No stem was revised for aseptic loosening. Nine stems were revised for other reasons. Radiographically, one stem was definitely loose at 16 years. The median patient Harris pain score improved from marked pain to no pain at latest follow-up. Patient activity level improved, albeit minimally, for 8 years after surgery. At latest follow-up, 98% of the patients remained satisfied with their surgery.

Conclusion

Primary THA with a cemented polished stem shows excellent results in young patients with pathology other than primary osteoarthritis. In addition, the stem design facilitates cement within cement exchange and therefore preservation of proximal femoral bone stock at revision surgery.  相似文献   

20.
During the period 1979 through 1986, 69 acetabular reconstructions in 63 patients were performed with the use of autologous morcellized bone-grafts because of acetabular bone stock loss. Nine cases (10 hips) were lost to follow-up. Eleven patients (12 hips) died <10 years after surgery; none had a revision. The results for the remaining 43 patients (47 hips) were reviewed at an average interval of 12.3 years (range, 10-17 years). No preoperative Harris hip score was available. The average Harris hip score at follow-up was 88 (range, 60-100). Radiographically, all grafts united. One hip developed a deep infection. Three other hips (6%) were revised because of aseptic loosening of the acetabular component. An additional 3 acetabular components were considered radiographic failures. Excluding the infected case, the overall survival rate of these acetabular reconstructions with a revision as endpoint was 94% at an average follow-up of 12.3 years. Reconstruction of acetabular bone stock loss with autologous morcellized bone-grafts is an attractive technique with a good potential for long-term success.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号