 共查询到17条相似文献,搜索用时 250 毫秒
1.
齐燕  欧陕兴  钱民  彭光明  刘波  刘玉品   《放射学实践》2012,27(10):1095-1099
目的:探讨运用双源CT双能量技术行冠状动脉血管成像的图像质量和辐射剂量。方法:204例患者分为两组行双源CT冠状动脉血管造影检查,A组采用双能量扫描方案,B组采用传统单能量扫描方案,比较两组的图像质量及辐射剂量。结果:A、B两组冠状动脉图像质量评分分别为(4.70±0.72)分、(4.70±0.71)分,两组间差异无统计学意义(t=-1.000,P=0.318)。A、B两组图像左、右冠状动脉信噪比(SNR)分别为A组20.0±3.4和19.0±3.0、B组20.1±3.2和19.9±3.2,且两组间差异均无统计学意义(t=1.967,P=0.051;t=-0.233,P=0.816)。A、B两组的容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效辐射剂量(ED)分别为(48.27±8.70)mGy、(54.10±8.77)mGy;(565.63±115.48)mGy.cm、(702.75±144.04)mGy.cm;(9.62±1.96)mSv、(11.95±2.45)mSv,A组的CTDIvol、DLP及ED明显低于B组,差异均有统计学意义(t=-4.764,P=0.000;t=-7.501,P=0.000;t=-7.501,P=0.000)。结论:双能量心肌灌注成像技术在不降低图像质量的情况下,能够显著降低患者的有效辐射剂量,有很高的临床应用价值。  相似文献   

2.
目的 探讨低kVp扫描技术在小儿心脏大血管CTA检查中降低辐射剂量的价值.方法 选取小儿先天性心脏病CTA检查病例39例分为两组,A组24例,B组1 5例.A组使用常规kVp 120,B组使用低kVp 90.记录两组病例扫描时机器自动显示的扫描长度(L)、容积CT剂量指数(CTDIvol)及剂量长度乘积(DLP).测量并计算左心房中部水平胸主动脉信噪比(SNR)、对比噪声比(CNR)以客观评价图像质量;双盲法主观评价心脏大血管后重组图像对肺动脉六分支的显示情况并给予优、良、差分级.对L、CTDIvol、DLP、E值、SNR及CNR进行t检验,主观图像质量评价采用x2检验.结果 A组和B组L分别为(10.40±1.97)cm和(9.54±1.72)cm,两组比较无统计学差异(P=0.169).A组和B组的CTDIvol分别为(11.6±0)mGy和(5.0±0)mGy,DLP为(120.67±22.55)mGy·cm和(47.68±8.61)mGy·cm,两组比较均有统计学差异(P<o.0001),B组比A组分别降低56.9%、60.5%.A组和B组SNR分别为(41.86±12.05)和(42.11±7.83)(P=0.944),CNR分别为(33.15±10.82)和(33.75±6.76)(P=0.850),两组比较无统计学差异.A组和B组的图像质量主观评判诊断满意率均达1oo%,统计学比较无差异.结论 小儿心脏大血管CTA检查使用低kVp扫描技术可以较大幅度降低辐射剂量,且不影响图像质量,具有较大的临床应用价值.  相似文献   

3.
_目的:探讨自动管电流调节(CARE Dose 4D)联合智能最佳 kV(CARE kV)技术在眼眶 CT 检查中的临床应用价值。方法:将行眼眶 CT 检查的70例患者分为两组,A 组(35例)采用 CARE Dose 4D 扫描技术,B 组(35例)采用CARE kV 联合 CARE Dose 4D 扫描技术。比较 A、B 两组图像质量(平均 CT 值、噪声 SD、SNR、CNR、图像质量主观评分)、患者所接受的辐射剂量及病变检出率。结果:A、B 两组辐射剂量差异有统计学意义(P<0.05),B 组[(0.59±1.55)mSv]较 A 组[(0.71±1.84)mSv]ED 较少约15.9%。两组平均 CT 值、噪声 SD、SNR、CNR、图像质量评分及病变检出率差异均无统计学意义(P>0.05)。结论:联合 CARE kV 与 CARE Dose 4D 技术行眼眶 CT 扫描,在保证图像质量的同时,可有效降低辐射剂量。  相似文献   

4.
目的通过对选用前瞻性心电门控扫描技术与回顾性心电门控扫描技术所得到的图像质量和放射剂量的对照研究,探讨双源CT(DSCT)前瞻性心电门控低剂量技术应用于婴幼儿先天性心脏病成像的可行性。方法连续搜集90例临床拟行双源CT胸部大血管检查的婴幼儿患者。随机分为两组,A组(45例)选用前瞻性心电门控扫描模式扫描。B组(45例)采用回顾性心电门控扫描模式扫描。由2名高年资的诊断医师以双盲法分别对A、B组图像进行图像质量评价,两组间图像质量差异用两独立样本Wilcoxon秩和检验进行分析。两组图像图像噪声、辐射剂量参数CTDI、DLP和ED差异用两独立样本均数f检验进行比较。结果A、B两组图像质量差异无统计学意义(H=O.098,P〉0.05);A、13两组噪声值分别为(13.25±1.27)HU,(13.51±1.41)HU,两组间噪声值差异无统计学意义(t=0.925,P〉0.05);A、B两组CTDI、DLP、ED分别为(2.70±0.75)mGy、(29.55±10.17)mGy/cm、(0.41±0.14)mSv;(3.81±1.03)mGy、(51.57±14.81)mGy/cm、(O.72±0.20)mSv;A组CTDI、DLP、ED明显低于B组,2组差异有统计学意义(t=5.36,8.13,8.13,P=0.001)。结论双源CT婴幼儿先天性心脏病成像时使用前瞻性心电门控扫描可以有效地减少受检者接受的x射线剂量,同时可以保证图像质量。  相似文献   

5.
目的探讨双源CT低kV和CARE Dose 4D管电流调节技术对降低主动脉CT血管成像(CTA)的辐射剂量的价值及其对图像质量的影响。资料与方法对临床拟诊主动脉夹层的53例患者行双源CT主动脉成像检查。并按数字表法将患者随机分为3组:A组:17例。扫描管电压为120 kV;B组:18例。扫描管电压为120 kV和CARE Dose 4D技术;C组:18例。扫描管电压为100 kV和CARE Dose 4D技术;3组其他扫描参数和重组参数均相同。测量气管分叉层面和肝门层面主动脉的CT强化值及图像噪声(SD),并由两名有经验的医师对3组图像质量进行评价。比较A组和B组、B组和C组平均容积CT剂量指数(CTDIvol),剂量长度乘积(DLP),有效剂量(ED),SD,信噪比(SNR),对比噪声比(CNR)和扫描长度。结果 A、B、C 3组图像质量评分依次为2.94±0.24、2.89±0.32、2.94±0.23。A、B、C 3组CTDIvol分别为(7.2±1.8)mGy、(6.1±1.4)mGy、(3.7±1.0)mGy;ED分别为(6.0±0.4)mSv、(5.0±1.0)mSv、(3.2±0.9)mSv;S...  相似文献   

6.
目的 探讨两种不同扫描方案下泌尿系统正常人群64层螺旋CT尿路成像(MSCTU)的图像质量和辐射剂量.方法 回顾性分析40名行64层MSCTU且最终证实无泌尿系统疾患的正常人群影像资料,CT扫描包括四期图像(平扫期、皮质期、髓质期、5分钟延迟期),延迟扫描分2组(120 kV组和100 kV组),每组20名,均采用CARE Dose 4D技术,参照管电流175 mAs.将2组延迟期图像的辐射剂量[平均容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效剂量(ED)]和图像质量[信噪比(SNR)、对比噪声比(CNR)、5分法图像质量评分]进行对照分析.结果 120 kV组和100 kV组泌尿系统延迟期图像CTDIvol分别为(7.04±1.07) mGy和(4.60±0.66)mGy,DLP分别为(308.80±60.00) mGy·om和(201.80 ±34.86)mGy·cm,ED分别为(4.63 ±0.90)mSy和(3.03 ±0.52)mSv,两组比较,在100 kV组辐射剂量明显低于120 kV组,差异有显著统计学意义(P均=0.000),而图像质量SNR分别为(102.34 ±29.66)和(109.87±33.21),CNR分别为(94.51 ±28.42)和(103.33±32.91),平均图像质量评分分别为(3.93 ±0.73)和(3.90±0.58),两组图像质量比较差异无统计学意义(P均>0.05).结论 MSCTU延迟期采用100 kV结合CARE Dose 4D技术能在不影响图像质量的前提下明显减少辐射剂量.  相似文献   

7.
目的:评价低剂量联合三维自适应迭代剂量降低算法(3D AIDR)在肥胖患者640层容积CT 冠状动脉成像(CTCA)中的应用价值。方法60例疑似冠心病的肥胖患者(体重指数BMI≥30kg/m2)以数值表法随机分成A、B两组行前瞻性心电门控扫描。A组以120kV管电压扫描,原始数据行传统滤波反投影(FBP)算法重建图像;B组以100kV管电压扫描,原始数据分别以FBP算法(B1组)和3D AIDR算法(B2组)重建图像。分别比较A组和B组各亚组间主观图像质量评分及噪声(SD)、平均CT值(SI)、信噪比(SNR)、对比信噪比(CNR)和有效辐射剂量(ED)的差异。结果 A组和B组有效辐射剂量分别为(5.37±0.49)mSv、(2.18±0.84)mSv ,平均减少了59%。A、B1、B2组三组质量平均得分分别为(2.22±0.97)和(1.41±1.09)、(2.28±0.98)。B组各亚组间的图像质量得分有统计学差异(t =-12.113,P <0.05),A与B2组的图像质量得分无统计学差异( t =0.963,P >0.05)。A组、B1组、B2组SI分别为(439.5±68.2) HU、(523.2±85.2)HU、(505.1±48.4)HU ;SD分别为32.1±6.8、64.8±6.9、38.6±7.4;SNR分别为12.6±5.7、8.3±3.2、13.8±5.1;CNR分别为11.2±3.4、7.5±6.9、11.6±2.8。B组各亚组间SD、SNR、CNR比较差异有统计学意义( t =2.378、0.812、1.461,P <0.05),B2组与 A 组SI和SD差异有统计学意义( t =-2.829、-0.241,P <0.05);SNR、CNR差异无统计学意义( t =1.128、0.672,P >0.05)。结论3D AIDR重建算法在同剂量情况下明显改善图像质量,联合低管电压扫描可获得满足诊断需求的冠状动脉图像质量,且辐射剂量大幅度降低。  相似文献   

8.
目的 探讨CT低剂量联合迭代算法在输尿管结石诊断中的应用价值.方法 90例输尿管结石患者在首次检查均应用常规剂量扫描(120 kV,400 mAs),采用滤波反投影算法(FBP)薄层重组,保守治疗后结石未排出.复查CT应用低剂量扫描随机分为3组(A组:120 kV,200 mAs;B组:120 kV,150 mAs;C组:120 kV,100 mAs)后分别行6级迭代算法薄层重组.由2名放射医师采用双盲法读片并对图像质量做主观评分,记录CT容积剂量指数(CTDIvol)、剂量长度乘积(DLP),计算辐射有效剂量(ED);测量图像的客观噪声值,计算信噪比,测量结石CT值及最大长径,记录结石检出数.结果 常规组:CTDIvol(23.51±0.79) mGy,DLP(1166.38±52.78)mGy·cm,ED(17.50±0.79)mSv;A组:CTDIvol(11.78±0.38) mGy,DLP(584.68±25.47) mGy· cm,ED(8.77±0.38) mSv;B组:CTDIvol(8.34±0.13)mGy,DLP(462.87±24.76) mGy· em,ED(6.94±0.37)mSv;C组:CTDIvol(5.47±0.21) mGy,DLP(268.20±19.03)mGy·cm,ED(4.02±0.29) mSv;各组低剂量迭代算法重组的iDose l ~6图像结石检出数、结石CT值及大小与常规剂量比较差异无统计学意义(P>0.05);A组低剂量迭代算法重组的iDose4图像噪声(SD)、信噪比(SNR)及iDose 4—6图像质量主观评分与常规剂量比较差异无统计学意义(P>0.05);B组低剂量迭代算法重建的iDose6图像噪声、信噪比及图像质量主观评分与常规剂量比较差异无统计学意义(P>0.05);C组低剂量迭代算法重建的iDose l~6各组图像噪声、信噪比及图像质量主观评分与常规剂量比较差异有统计学意义(P<0.05).结论 CT低剂量扫描联合迭代算法诊断输尿管结石是可行的,可以在不影响图像质量的前提下明显减低辐射剂量.管电压120 kV情况下,在iDose6水平管电流150mAs为最低临界扫描参数.  相似文献   

9.
目的:对三种不同管电压条件下的 Flash模式小儿肺C T图像质量进行评价,探讨低电压扫描的可行性。方法前瞻性分析93例患儿胸部双源CT Flash模式检查资料,按照不同管电压随机分为三组(组1:80kV ,34例;组2:100kV ,29例;组3:120kV ,30例)。两位放射科医师独立对图像质量采用4分制评分;记录每组有效 mAs、CTDlvol和DLP ,测量图像密度及噪声,计算信噪比(SNR)、有效辐射剂量(ED)。结果①三组图像质量得分〔(3.12±0.640)、(3.69±0.471)、(3.80±0.407)〕及S N R〔(4.25±0.945)、(5.46±1.790)、(5.88±1.665)〕在组1、2和组1、3间均有统计学差异( P <0.05),组2、3间无统计学差异( P >0.05);②三组间的CTDlvol〔(1.05±0.056) mGy、(2.14±0.306) mGy、(2.63±0.697)mGy〕及ED〔(0.69±0.086) mSv、(1.36±0.250)mSv、(1.84±0.808)mSv〕均具有统计学差异( P<0.05)。结论100kV下CT Flash模式较80kV和120kV具有综合优势,在降低辐射剂量的同时能够保证高图像质量,对小儿肺部检查,尤其是小气道、肺间质等细微结构的观察具有显著临床意义。  相似文献   

10.
目的探讨双源CT前瞻性心电门控大螺距扫描模式下70kV管电压结合迭代算法在CCTA检查中降低辐射剂量及对比剂用量的可行性,并探讨图像最佳迭代重建等级。方法收集本院90例行CCTA检查的患者,体质量指数(BMI)≤25kg/m~2,分为2组,每组45例。A组扫描方案:前瞻性心电门控大螺距螺旋扫描模式,固定管电压70kV,自动管电流调制,参考管电流500mAs;对比剂注射流率及容量分别为4.0ml/s、0.8ml/kg;B组扫描方案:自适应前瞻性心电门控触发序列,自动管电压及管电流调制,参考管电压120kV,参考管电流320mAs,对比剂注射流率及容量分别为5.0ml/s、1.0ml/kg。A组图像采用FBP及SAFIRE1~5等级重建,B组采用SAFIRE3级重建。比较A组各迭代等级及FBP重建间的图像质量,得出最佳迭代等级图像后与B组图像比较图像质量、图像噪声、SNR、CNR及辐射剂量等;并比较两组患者的一般资料。结果 A组SAFIRE 3图像质量评分最高;两组患者一般资料、图像噪声、图像质量评分无统计学差异(P0.05)。部分节段血管SNR、CNR具有统计学差异,但A组高于B组。A组CTDIvol(0.70±0.12)mGy、DLP(12.56±2.37)mGy·cm、ED(0.18±0.33)mSv均明显低于B组CTDIvol(12.24±6.82)mGy、DLP(158.80±81.57)mGy·cm、ED(2.22±1.14)mSv。结论对于BMI≤25kg/m~2的患者,双源CT大螺距扫描模式下70kV管电压结合迭代算法CCTA检查,能够在得到满足临床诊断要求的图像质量的同时,明显降低有效辐射剂量(ED0.3mSv)及对比剂用量。  相似文献   

11.
目的 探讨在超重患者双源CT冠状动脉成像中低管电压技术的应用价值,评价其图像质量和辐射剂量.方法 将66例接受双源CT冠状动脉检查,体质量<85 kg、且体质量指数(BMI)为25.0~30.0 ks/m2的患者完全随机化分为A、B 2组.A组30例,管电压为120 kVp;B组36例,管电压为100 kVp.所有患者均采用回顾性心电门控螺旋扫描和四维智能在线剂量调控(CARE Dose 4D)技术,严格控制扫描范围.对2组的扫描数据分别进行多种图像后处理,由影像科副主任医师和副主任技师各1名采用双盲法评估图像质量.测量并计算信噪比(SNR)、对比信噪比(CNR).记录CT容积剂量指数(CTDIvol)和剂量长度乘积(DLP),计算有效辐射剂量(ED).应用两独立样本t检验比较2组患者图像ROI的CT值、噪声、SNR、CNR、辐射剂量及对比剂用量、图像质量评分等.应用X2检验比较两组患者冠状动脉图像质量分级显示段数.应用Kappa检验判断2名评价者评分的一致性.以P<0.05为差异有统计学意义.结果 图像ROI内CT值、噪声(以标准差SD计算)、SNR测量值:A组右冠状动脉(RCA)起始部分别为(429.3±77.4)HU,24.0±8.2、21.8±9.9,左冠状动脉主干(LMA)起始部分别为(436.7±79.0)HU、19.4±7.3、22.3±9.8;B组RCA分别为(503.5±95.4)HU、34.0±12.6、21.0±10.7,LMA分别为(491.7±96.2)HU、33.4±15.5、20.6±11.4;CNR测量值:A组为24.4±10.3,B组为21.9±8.2.2组患者冠状动脉血管腔内强化平均CT值、噪声比较,B组大于A组,差异有统汁学意义(P值均<0.05);2组间SNR、CNR筹异无统计学意义(P值均>0.05);2组CTDIvol比较,A组为(42.2±13.8)mGy,B组为(20.2±6.5)mGy,差异有统计学意义(P<0.05);A组ED为(9.5±3.6)roSy,B组为(4.8±1.7)mSv,差异有统汁学意义(P<0.05);A组图像质量评分为(4.5±1.0)分,B组为(4.7±0.5)分,筹异无统计学意义(P>0.05);A绀评价383段冠状动脉,图像优良者377段(98.4%)B组评价490段冠状动脉,图像优良者483段(98.6%).结论 对于BMI在25.0~30.0 kg/m2的患者,使用100 kVp管电压配合CARE Dose 4D技术进行双源CT冠状动脉检查,可以获得较好的图像质量,并且可以显著降低辐射剂量.
Abstract:
Objective To investigate the image quality and the radiation dose of dual-source computed tomography coronary angiography by using low kilovohage combination with low tube current in overweight patients.Methods Sixty-six patients with body mass inde,(BMI)25.(0-30.0 kg/m2 and a body weight<85 kg were randomized two groups(group A and group B).Thirty patients in group A were examined with 120 kVp,and 36 patients in group B with 100 kVp.ECG-pulsing and care dose 4D for radiation dose reduction were used in all patients.All images were transferred to Siemens workstation for post processing and analysis.Two observers blimted to clinical data independently assessed the image quality of each coronary segment by using a 5-point scoring scale(5:excellent,1:no diagnostic).and measured the different image parameters including image noise,signal-to-noise ratio(SNR)and contrast-to-noise ratio (CNR).The effective dose(ED)was calculated by using CT dose volume index(CTDIvol)and the doselength product (DLP). The mean intraluminal attenuation, image noise, SNR, CNR, radiation dose,volume of contrast medium, and mean image quality scores were compared between the two groups with t test. The grading quantity of coronary artery segment was compared with Chi-square test. The interobserver agreement was determined by Kappa statistics. Results The mean intraluminal attenuation, image noise,SNR in group A were (429. 3±77.4 ) HU, 24.0±8.2, 21.8±9. 9 in right coronary artery ( RCA), and (436. 7±79. 0) HU, 19.4±7.3, 22. 3±9. 8 in left main coronary artery (LMA ), and that in group B were (503.5±95.4) HU, 34.0±12.6, 21.0±10.7 in RCA, and (491.7±96.2) HU, 33.4±15.5,20.6±11.4 in LMA. The CNR were 24.4±10.3 in group A and 21.9±8.2 in group B. The mean intraluminal attenuation and image noise were significantly higher for group B compared with group A ( P <0. 05 ). There were no difference in SNR and CNR between the two groups ( P > 0. 05 ). Estimated ED in group B was significantly lower than that in group A [CTDIvol = (42. 2±13. 8) mGy, ED = (9. 5±3.6)mSv in group A vs. CTDIvol = ( 20. 2±6.5 ) mGy, ED = (4. 8±1.7 ) mSv in group B ; each P < 0. 05 ].Mean image quality scores were not significantly different between two groups ( 4. 5±1.0 in group A vs.4. 7±0. 5 in group B, P > 0. 05 ). A total of 383 coronary artery segments were evaluated in group A and 490 segments in group B. The difference of grading quantity of coronary artery segment was no statistical significant between two groups. Conclusions 100 kVp combination with ECC-pulsing and CARE Dose 4D of dual-source CTCA was valuable for patients with BMI ranging from 25 to 30 kg/m2 which have a better image quality and low radiatiun dose.  相似文献   

12.
目的 探讨64层CT低剂量扫描在胸主动脉CT血管造影(CTA)成像中的临床应用研究。方法 应用64层CT对100例胸厚为22~23cm疑似胸主动脉疾病的患者分成5组进行胸主动脉CTA扫描,扫描范围为250~300mm,扫描条件为机器默认的120kV、350mAs,然后固定120kV,用300mAs、250mAs、200mAs及150mAs对其它四组患者进行扫描,记录不同mAs的CTDIvol及DLP,并转换为有效剂量ED。2位影像学家对上述图像进行SNR、CNR及主观评价。结果 将120kV、350mAs及300mAs、250mAs、200mAs及150mAs扫描产生的图像传至机器工作站进行SNR及CNR计算,其值分别为:4.81、4.02、2.59、1.73、1.57和3.81、3.27、1.86、0.92、0.94。2位影像学家对120kV下350~150mAs主观评价分值分别为:4.61±0.72,4.48±0.30,4.52±0.28,4.28±0.36,3.65±0.38;其CTDIvol、DLP分别为:10.08mGy、8.73mGy、7.14mGy、5.68mGy、4.21mGy和352.8mGy、309.32mGy、255.46mGy、203.8mGy、171.08mGy,将DLP转换为ED为5.29mSv、4.64mSv、3.83mSv、3.06mSv、2.57mSv。对上述数据进行单因素方差分析,200mAs和350mAs、300mAs、250mAs产生的影像质量没有明显差异,但200mAs的CTDIvol、DLP及ED较350mAs分别低43.7%、42.2%及43.7%。结论 胸厚为22~23cm的患者进行胸主动脉CTA扫描推荐mAs为200mAs。对于体型较小(肌肉较少)或有肺气肿等疾病可以选用150mAs及以下条件进行扫描。  相似文献   

13.
目的:探讨多层螺旋 CT 低剂量扫描技术在甲状腺增强扫描中的临床应用价值。方法80例患者随机分为4组(每组各20例),4组分别为:A 组,120 kV、180 mA;B 组,120 kV、100 mA;C 组,100 kV、180 mA;D 组,100 kV、100 mA。主观评价图像质量并评分,统计甲状腺 CT 值、图像背景噪声(N)、图像信噪比(SNR)、CT 剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效辐射剂量(ED)并进行对比分析。结果4组图像主观评分为3.90±0.31、3.75±0.44、3.70±0.47、3.60±0.60,SNR 为26.34±3.13、25.08±1.87、25.86±2.38、24.87±2.20,四者无统计学差异(P >0.05);甲状腺 CT 值为(168.55±13.39)HU、(170.70±11.34)HU、(185.20±22.35)HU、(190.55±21.38)HU,N 为(6.48±0.84)HU、(6.83±0.45)HU、(7.19±0.86)HU、(7.66±1.01)HU, CTDIvol 为(10.95±0.00)mGy、(6.08±0.00)mGy、(6.59±0.00)mGy、(3.66±0.00)mGy,DLP 为(145.67±8.79)mGy·cm、(84.58±4.94)mGy·cm、(89.86±3.26)mGy·cm、(50.20±1.89)mGy·cm,ED 为(0.73±0.04)mSv、(0.42±0.03)mSv、(0.45±0.03)mSv、(0.25±0.01)mSv,四者有统计学差异(P <0.05)。结论多层螺旋 CT 低剂量扫描技术既能保证图像质量又能有效降低甲状腺增强 CT 检查的辐射剂量。  相似文献   

14.
螺旋CT颈椎低剂量扫描及重建的临床价值评价   总被引:1,自引:0,他引:1  
目的:探讨螺旋CT颈椎低剂量扫描及重建的临床价值及其可行性。方法:将需行颈椎椎体扫描的患者30例,随机分为常规剂量组和低剂量组,其中常规剂量组(CDG)10例,低剂量组(LDG)20例;并选择同期行椎间盘扫描患者20例作为对照组(CG),记录辐射剂量、有效剂量,原始图像及重建图像均传输至PACS系统,由2位经验丰富的放射科医师对图像质量进行评分;测量椎体周围肌肉及背景(空气)的CT值。采用F检验进行统计分析。结果:LDG的容积CT剂量指数(CTDIv-ol)为6.5 mGy,剂量长度积(DLP)为(98.21±2.47)mGycm,有效剂量(ED)为(0.53±0.01)mSv;CDG的CTDIvol为19.1 mGy,DLP为(287.84±27.94)mGycm,ED为(0.53±0.01)mSv;CG的CTDIvol为26.5 mGy,DLP为106.0 mGycm,ED为0.57 mSv。统计分析发现,CDG与LDG、CDG与CG的DLP差异有统计学意义(P=0.000);LDG与CG的DLP差异无统计学意义(P=0.326)。CDG与LDG、CDG与CG的ED差异有统计学意义(P=0.000);LDG与CG的ED差异无统计学意义(P=0.326)。椎体扫描低剂量组的辐射剂量少于常规剂量组。LDG原始图像得分为(4.48±0.24)分;CDG的原始图像得分为(4.60±0.23)分;CG图像得分为(4.51±0.19)分。组间比较椎间盘的图像评分差异无统计学意义(P0.05),LDG的图像得分均高于4分。LDG的肌肉组织及背景(空气)CT值的标准差(SD肌肉=6.1;SD背景=20.5)均大于CG(SD肌肉=3.2;SD背景=13.9)和CDG(SD肌肉=5.8;SD背景=2.3)。结论:采用螺旋CT行颈椎椎体扫描并重建具有可行性。优化参数可以明显减少辐射剂量。与单纯椎间盘扫描相比,该检查方法并没有增加患者的辐射剂量,而提供的信息却大大增加,因此更具有临床价值。  相似文献   

15.
目的 比较第一代与Flash双源CT不同扫描方式在肺动脉成像时剂量与图像质量.方法 收集120例临床疑诊为PE患者,按扫描方式随机分为4组:A组行第一代双源CT双能量扫描(80/140kV),B组行flash双源CT双能量扫描(80/sn140kV),C组行flash双源CT双能量扫描(100/sn140kV),D组行flash双源CT双能量扫描(140/80kV).比较4组间的CT容积剂量指数(CT dose volume index,CTDIvol)、剂量长度乘积(dose length product,DLP)、背景噪声和肺动脉信噪比.结果 各组间患者一般情况没有明显统计学差异.B组的CTDIvol,DLP值明显低于A、C两组,图像质量明显好于D组.结论 flash双源CT(80/sn140kV)在获得满意的图像质量的同时可以减低辐射剂量.  相似文献   

16.
多层螺旋CT膝关节低剂量扫描对影像质量的影响   总被引:1,自引:0,他引:1  
目的:探讨多层螺旋CT低剂量膝关节扫描的可行性及其对图像质量的影响。方法:收集2009年5月~10月,100例行膝关节CT扫描者根据扫描的管电压高低分为2组(其他扫描条件不变),每组50例,A组110kV和B组80kV(管电压选择110kV和80kV是依据分别观察10例在此条件下扫描的患者图像,应用80kV而不影响诊断)。测量膝关节髌骨上缘水平后方肌肉软组织固定ROI的CT值,以CT值的标准差(SD)作为图像噪声。通过CT机自动得到平均容积CT剂量指数(CTDIvol),再计算出剂量长度乘积(DLP)。获得的图像通过双盲法进行质量评分,对两组CTDIvol值、DLP值、图像噪声、及图像质量评分均值用t检验进行比较。结果:A组和B组的CTDIvol值分别为(5.29±0.23)和(2.08±0.15)mGy,DLP值分别为(61.26±11.64)和(24.21±4.64)mGy.cm,B组较A组下降约(60.68)%,两者之间差异均有统计学意义(t值分别为(82.4)和(20.91),P0.01,B组噪声均值略高于A组(分别为12.22±2.97和16.55±2.96),t=-7.299,P=0.000,但两组图像质量平均评分分别为(4.86±0.40)分和(4.82±0.44)分,差异无统计学意义(t=0.475,P0.05)。结论:16层螺旋CT应用低kV设置(80kV)扫描膝关节可大幅度降低辐射剂量且所得图像质量不影响诊断。  相似文献   

17.
目的 探讨中低心率对双源CT低管电压冠状动脉成像的图像质量及辐射剂量的影响.方法 对85例体质量指数(BMI)为17.51~30.00 kg/m2、心率在91次/min(bpm)以下的可疑冠心病患者进行双源CT低管电压(100 kVp)回顾性心电门控冠状动脉成像增强扫描,检查前不使用β受体阻滞剂控制心率.按患者扫描时的心率进行分组,≤59 bpm为A组(27例),60~69 bpm为B组(29例),≥70 bpm为C组(29例).评价各组的最佳重建时相图像,记录各组的增强扫描序列的螺距、CT容积剂量指数(CTDvol)、剂量长度乘积(DLP)及有效剂量(ED)值.应用单因素方差分析比较3组患者的扫描螺距、图像质量评分和辐射剂量值等.分析心率对冠状动脉成像图像质量及辐射剂量的影响.结果 A、B、C组螺距分别为0.241±0.025、0.286±0.034、0.335±0.036;3组图像质量评分分别为(4.78±0.26)、(4.66±0.56)、(4.70±0.46)分;CTDIvol值分别为(18.06±5.16)、(19.62±7.15)和(17.50±7.13)mGy,ED值分别为(4.23±1.16)、(4.59±1.75)、(4.12±1.39)mSv.3组的螺距差异有统计学意义(F=60.00,P=0.00);3组间的图像质量评分差异无统计学意义(F=0.53,P=0.59);3组间CTDIvol差异无统计学意义(F=0.83,P=0.44),ED差异也无统计学意义(F=0.86,P=0.43).结论 中低心率对双源CT低管电压冠状动脉成像的图像质量影响很小,在自动心电门控剂量窗时,对辐射剂量的影响也很小.
Abstract:
Objective To evaluate the imaging quality and radiation doses of dual-source computed tomography (DSCT) coronary angiography at a low tube voltage in patients with medium and low heart rate.Methods Eighty-five patients[heart rate (HR) < 91 beats per minute (bpm); body mass index (BMI) 17. 51-30. 00 kg/m2]suspected of coronary artery disease received retrospectively ECG-gating coronary angiography with dual-source CT scanner (Somatom Definition, Siemens) at a tube voltage of 100 kVp. For all patients, no beta-blocker was used before CT scan. According to the HR, the patients were divided into three groups: Group A, HR ≤ 59 bpm, n = 27; Group B, HR 60-69 bpm, n = 29; Group C,HR ≥70 bpm, n = 29. All images were transferred to a workstation for postprocessing. The best R-R interval reconstruction images of all groups were evaluated. The value of pitch, CT volume dosage index (CTDIvol), dose length product (DLP)and effective dose (ED)were recorded. The pitch, the score of imaging quality of coronary artery segments and the radiation dose were compared with one-way ANOVA. The influence of HR on image quality and radiation doses of coronary artery was analyzed. Results The value of pitch in Group A, Group B and Group C was 0. 241 ± 0. 025, 0. 286 ± 0. 034 and 0. 335 ± 0. 036,respectively. The mean score of imaging quality of coronary artery segments in Group A, Group B and Group C was 4. 78 ± 0. 26, 4. 66 ± 0. 56 and 4. 70 ± 0. 46, respectively. The value of CTDIvol in Group A,Group B and Group C was (18.06 ±5. 16), (19. 62 ±7. 15) and (17. 50 ±7. 13) mGy, respectively. The value of ED in group A, Group B and Group C was (4.23 ± 1.76), (4.59 ± 1.75) and (4.12 ±1.39) mSv, respectively. There was statistical difference in value of pitch among the three groups (F =60. 00, P= 0. 00). There were no statistical difference in score of imaging quality, CTDIvol and value of ED among the three groups (F = 0. 53, P = 0. 59; F = 0. 83, P = 0. 44 ; F = 0. 86, P = 0. 43). Conclusion Medium and low HR have little influences on image quality of dual-source CT coronary angiography at a low tube voltage. When the auto ECG-gating is selected, there is little influence on radiation dosage as well.  相似文献   