首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Objective:

Multiparametric MRI (mp-MRI) of the prostate is increasingly being used for local staging and detection of recurrence of prostate cancer (PCA). In patients with elevated prostate-specific antigen (PSA), mp-MRI could provide information on the position of the cancer, allowing adjustments to be made to the needle depth and direction before repeat transrectal ultrasound (TRUS)-guided biopsy to ensure accurate sampling of lesions. The purpose of the prospective study was to evaluate mp-MRI of the prostate in patients with PSA elevation before initial TRUS-guided biopsy.

Methods:

mp-MRI was performed in 94 patients using a 1.5-T scanner (MAGNETOM Aera®; Siemens Healthcare, Erlangen, Germany) and 16-channel phased-array body coil (Siemens Healthcare). T2 weighted images (T2WI), diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE) MRI and MR spectroscopy were obtained. TRUS-guided random biopsies and additional targeted biopsies of suspicious MRI areas were performed.

Results:

Additional targeted biopsies were obtained in 17 of 43 (40%) patients with PCA. 11 of 17 targeted biopsies contained PCA. 5 of 11 PCAs were diagnosed only by additional targeted biopsies. Sensitivity of mp-MRI in patients was 97.7% and specificity was 11.8%. mp-MRI was false negative in one patient. Sensitivity of mp-MRI in 207 lesions was 80.9% and specificity was 44.7%. In a logistic regression model, the apparent diffusion coefficient value was the only significant parameter to differentiate malignant and benign lesions.

Conclusion:

mp-MRI should be performed in patients with PSA elevation before initial TRUS-guided biopsy to allow additional targeted biopsies from suspicious areas of MRI. We recommend mp-MRI with T2WI, DWI, DCE MRI and MR spectroscopy. DWI as the most reliable technique should be used in every mp-MRI.

Advances in knowledge:

DWI is the most reliable technique in mp-MRI of the prostate.  相似文献   

2.
We assessed the accuracy of T2-weighted (T2w) and dynamic contrast-enhanced (DCE) 1.5-T magnetic resonance imaging (MRI) in localizing prostate cancer before transrectal ultrasound-guided repeat biopsy. Ninety-three patients with abnormal PSA level and negative prostate biopsy underwent T2w and DCE prostate MRI using pelvic coil before repeat biopsy. T2w and DCE images were interpreted using visual criteria only. MR results were correlated with repeat biopsy findings in ten prostate sectors. Repeat biopsy found prostate cancer in 23 patients (24.7%) and 44 sectors (6.6%). At per patient analysis, the sensitivity, specificity, positive and negative predictive values were 47.8%, 44.3%, 20.4% and 79.5% for T2w imaging and 82.6%, 20%, 24.4% and 93.3% for DCE imaging. When all suspicious areas (on T2w or DCE imaging) were taken into account, a sensitivity of 82.6% and a negative predictive value of 100% could be achieved. At per sector analysis, DCE imaging was significantly less specific (83.5% vs. 89.7%, p < 0.002) than T2w imaging; it was more sensitive (52.4% vs. 32.1%), but the difference was hardly significant (p = 0.09). T2w and DCE MRI using pelvic coil and visual diagnostic criteria can guide prostate repeat biopsy, with a good sensitivity and NPV.  相似文献   

3.
The purpose of this study was to examine the feasibility and safety of MR-guided biopsies with a transgluteal approach in patients with uncertain or suspicious prostate lesions. Twenty-five patients with uncertain or suspicious focal prostate lesions detected by high-field MR imaging of the prostate gland using endorectal coil imaging were biopsied with a transgluteal approach in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted FLASH sequences. The prostate gland was biopsied repeatedly with a coaxial technique through a 15-gauge pencil tip with a 16-gauge biopsy handy (median 3.8 samples per patient). Complications and biopsy findings were documented retrospectively. Using T1-weighted sequences biopsy procedures were performed successfully with MR guidance in all cases without any side effects or complications. The median intervention time was 11.3 min. Pathological findings revealed ten cases of hyperplasia or atrophy, three cases of prostatitis, ten cases of carcinoma and two cases of normal tissue. The clinical follow-up showed that in two patients prostate cancer was missed at MR-guided biopsy. Transgluteal MR-guided biopsy of the prostate gland is a safe and promising approach for histological clarification of uncertain or suspicious lesions.  相似文献   

4.

Objectives

To evaluate the Prostate Imaging Reporting and Data System (PI-RADS) proposed by the European Society of Urogenital Radiology (ESUR) for detection of prostate cancer (PCa) by multiparametric magnetic resonance imaging (mpMRI) in a consecutive cohort of patients with magnetic resonance/transrectal ultrasound (MR/TRUS) fusion-guided biopsy.

Methods

Suspicious lesions on mpMRI at 3.0 T were scored according to the PI-RADS system before MR/TRUS fusion-guided biopsy and correlated to histopathology results. Statistical correlation was obtained by a Mann–Whitney U test. Receiver operating characteristics (ROC) and optimal thresholds were calculated.

Results

In 64 patients, 128/445 positive biopsy cores were obtained out of 95 suspicious regions of interest (ROIs). PCa was present in 27/64 (42 %) of the patients. ROC results for the aggregated PI-RADS scores exhibited higher areas under the curve compared to those of the Likert score. Sensitivity/specificity for the following thresholds were calculated: 73 %/92 % and 85 %/67 % for PI-RADS scores of 9 and 10, respectively; 85 %/56 % and 60 %/97 % for Likert scores of 3 and 4, respectively.

Conclusions

The standardised ESUR PI-RADS system is beneficial to indicate the likelihood of PCa of suspicious lesions on mpMRI. It is also valuable to identify locations to be targeted with biopsy. The aggregated PI-RADS score achieved better results compared to the single five-point Likert score.

Key points

? The ESUR PI-RADS scoring system was evaluated using multiparametric 3.0-T MRI. ? To investigate suspicious findings, transperineal MR/TRUS fusion-guided biopsy was used. ? PI-RADS can guide biopsy locations and improve detection of clinically significant cancer. ? Biopsy procedures can be optimised, reducing unnecessary negative biopsies for patients. ? The PI-RADS scoring system may contribute to more effective prostate MRI.  相似文献   

5.
ObjectiveTo evaluate the impact of multiparametric magnetic resonance imaging (mpMRI) before confirmatory prostate biopsy in patients under active surveillance (AS).Materials and MethodsThis retrospective study included 170 patients with Gleason grade 6 prostate cancer initially enrolled in an AS program between 2011 and 2019. Prostate mpMRI was performed using a 1.5 tesla (T) magnetic resonance imaging system with a 16-channel phased-array body coil. The protocol included T1-weighted, T2-weighted, diffusion-weighted, and dynamic contrast-enhanced imaging sequences. Uroradiology reports generated by a specialist were based on prostate imaging-reporting and data system (PI-RADS) version 2. Univariate and multivariate analyses were performed based on regression models.ResultsThe reclassification rate at confirmatory biopsy was higher in patients with suspicious lesions on mpMRI (PI-RADS score ≥ 3) (n = 47) than in patients with non-suspicious mpMRIs (n = 61) and who did not undergo mpMRIs (n = 62) (66%, 26.2%, and 24.2%, respectively; p < 0.001). On multivariate analysis, presence of a suspicious mpMRI finding (PI-RADS score ≥ 3) was associated (adjusted odds ratio: 4.72) with the risk of reclassification at confirmatory biopsy after adjusting for the main variables (age, prostate-specific antigen density, number of positive cores, number of previous biopsies, and clinical stage). Presence of a suspicious mpMRI finding (adjusted hazard ratio: 2.62) was also associated with the risk of progression to active treatment during the follow-up.ConclusionInclusion of mpMRI before the confirmatory biopsy is useful to stratify the risk of reclassification during the biopsy as well as to evaluate the risk of progression to active treatment during follow-up.  相似文献   

6.

Purpose:

To prospectively evaluate multiparametric magnetic resonance imaging (MRI) for accurate localization of intraprostatic tumor nodules, with whole‐mount histopathology as the gold standard.

Materials and Methods:

Seventy‐five patients with biopsy‐proven, intermediate, and high‐risk prostate cancer underwent preoperative T2‐weighted (T2w), dynamic contrast‐enhanced (DCE) and diffusion‐weighted (DW) MRI at 1.5T. Localization of suspicious lesions was recorded for each of 24 standardized regions of interest on the different MR images and correlated with the pathologic findings. Generalized estimating equations (GEE) were used to estimate the sensitivity, specificity, accuracy, positive, and negative predictive value for every MRI modality, as well as to evaluate the influence of Gleason score and pT‐stage. Tumor volume measurements on histopathological specimens were correlated with those on the different MR modalities (Pearson correlation).

Results:

DW MRI had the highest sensitivity for tumor localization (31.1% vs. 27.4% vs. 44.5% for T2w, DCE, and DW MRI, respectively; P < 0.005), with more aggressive or more advanced tumors being more easily detected with this imaging modality. Significantly higher sensitivity values were obtained for the combination of T2w, DCE, and DW MRI (58.8%) as compared to each modality alone or any combination of two modalities (P < 0.0001). Tumor volume can most accurately be assessed by means of DW MRI (r = 0.75; P < 0.0001).

Conclusion:

Combining T2w, DCE, and DW imaging significantly improves prostate cancer localization. J. Magn. Reson. Imaging 2013;37:1392–1401. © 2012 Wiley Periodicals, Inc.  相似文献   

7.
OBJECTIVE: High soft-tissue contrast and multiplanar imaging capabilities of MRI may be advantageous in biopsy guidance compared to CT. We report our first results with MR-guided core biopsies using a closed 1.0 T MR imager. METHODS AND PATIENTS: In ten patients, seven liver lesions and one lesion each in the muscle of the back, the gluteal muscle and in the breast were biopsied under MR guidance using MR-compatible needles (Tru-Cut type, 18G and 14G). For control scans T1-weighted turbo-spin-echo (TSE), gradient-echo and T2-weighted TSE sequences were used. RESULTS: In all patients, the suspicious lesions and the biopsy needle were exactly delineated in MR control scans. In nine out of ten patients, the suspicious lesion was clarified histologically. Controls of needle position in a second plane were performed twice. Pushing the inner stylet alone resulted in a distortion of the needle in several cases in its flat area. The small diameter of the MR gantry was inconvenient for a few patients. One complication (intrahepatic bleeding) was observed, which healed up without consequences. CONCLUSION: Using a closed 1.0 T MR imager MR-guided core biopsies can be conducted efficiently. Core biopsies should be taken by pulling and pushing the outer cannula. Advantageous compared to CT are the multiplanar imaging capabilities, while the smaller gantry is disadvantageous.  相似文献   

8.
Transnasal and transsphenoidal MRI-guided biopsies of petroclival tumors   总被引:2,自引:0,他引:2  
Magnetic resonance imaging (MRI) allows excellent tissue characterization in the area of the petroclival region and can depict lesions not visualized with ultrasound or computed tomography (CT). The aim of this study was to demonstrate the clinical feasibility and utility of an interactive MR-guidance system to target and biopsy tumors in the petroclival region. MRI-guided biopsies of 10 patients with tumors in the clivus and petrous apex were performed in an open 0.5-T MR system. Lesions were targeted through a transsphenoidal or transnasal approach. Imaging during biopsies was achieved by a combination of standard and interactive mode. T1-weighted spin-echo, T2-weighted fast spin-echo (FSE), and three-dimensional T1-weighted gradient-echo (GRE) scans (standard mode) were selected to provide optimal tissue characterization for both the lesion and surrounding structures and varied according to the anatomic site. For interactive imaging, T1-weighted GRE and T2-weighted FSE sequences were used. We performed MRI-guided transsphenoidal biopsies in 10 patients who had lesions identified by CT (n = 5) and/or MRI (n = 10). The indications for biopsies were to differentiate between suspected malignant processes (n = 4 ) and benign processes (n = 6). Lesions adjacent to structures like the internal carotid artery were accurately targeted in particular. All biopsies were performed successfully and were the basis for selection of further treatment. No complications occurred during the procedures. An open MR system allows interactive control of biopsies in the area of the petroclival region, providing maximum patient safety and diagnostic accuracy not possible in other systems. The advantages of MRI tissue characterization are combined with an interactive, one-step method of localization and targeting, as well as tissue sampling. J. Magn. Reson. Imaging 2001;13:3-11.  相似文献   

9.

Objective

We assessed which information from a prostate biopsy had the strongest relationship with prostate cancer detection by 3T-MRI.

Materials and methods

Sixty-one consecutive patients with biopsy-proven prostate cancer who underwent 3T-MRI before biopsy were enrolled in this retrospective study. Two radiologists independently reviewed T2-weighted and diffusion-weighted images. When the cancer lesions were revealed by biopsy and MRI depicted them at corresponding sites, we classified these lesions as MRI-detectable cancer. If the cancer lesions were revealed by biopsy, but any cancers had not been detected, we classified these lesions as MRI-undetectable cancer. We compared the Gleason score (GS), cancer ratio (CaR) and cancer length (CaL) from core biopsies between the two groups.

The results

GS, CaR and CaL differed significantly between the MRI-detectable group (N = 70), and the MRI-undetectable group (N = 73). 3T-MRI could detect cancer cores with a sensitivity of 90.5 % in cores with CaR ≥ 60 %, and with a sensitivity of 81.8 % in those with CaL ≥ 5 mm. Receiver operating characteristic analysis showed that CaR (P = 0.006) and CaL (P = 0.010) significantly associated with the prostate cancer detection using MRI rather than GS.

Conclusion

CaR and CaL from the core biopsies showed a stronger relationship to detection of the prostate cancer on 3T-MRI than the GS did.
  相似文献   

10.
PurposeTo determine the diagnostic performance of texture analysis of prostate MRI for the diagnosis of prostate cancer among Prostate Imaging Reporting and Data System (PI-RADS) 3 lesions.Materials and MethodsForty-three patients with at least 1 PI-RADS 3 lesion on prostate MRI performed between June 2016 and January 2019 were retrospectively included. Reference standard was pathological analysis of radical prostatectomy specimens or MRI-targeted biopsies. Texture analysis extraction of target lesions was performed on axial T2-weighted images and apparent diffusion coefficient (ADC) maps using a radiomic software. Lesions were categorized as prostate cancer (Gleason score [GS] ≥ 6), and no prostate cancer. Statistical analysis was performed using the generalized linear model (GLM) regression and the discriminant analysis (DA). AUROC with 95% confidence intervals were calculated to assess the diagnostic performance of standalone features and predictive models for the diagnosis of prostate cancer (GS ≥ 6) and clinically-significant prostate cancer (GS ≥ 7).ResultsThe analysis of 46 PI-RADS 3 lesions (ie, 27 [58.7%] no prostate cancers; 19 [41.3%] prostate cancers) revealed 9 and 6 independent texture parameters significantly correlated with the final histopathological results on T2-weighted and ADC maps images, respectively. The resulting GLM and DA predictive models for the diagnosis of prostate cancer yielded an AUROC of 0.775 and 0.779 on T2-weighted images or 0.815 and 0.821 on ADC maps images. For the diagnosis of clinically-significant prostate cancer, the resulting GLM and DA predictive models for the diagnosis of prostate cancer yielded an AUROC of 0.769 and 0.817 on T2-weighted images or 0.749 and 0.744 on ADC maps images.ConclusionTexture analysis of PI-RADS 3 lesions on T2-weighted and ADC maps images helps identifying prostate cancer. The good diagnostic performance of the combination of multiple radiomic features for the diagnosis of prostate cancer may help predicting lesions where aggressive management may be warranted.  相似文献   

11.
In recent years magnetic resonance imaging (MRI) has been increasingly established in the diagnosis of prostate cancer in addition to transrectal ultrasonography (TRUS). The use of T2-weighted imaging allows an exact delineation of the zonal anatomy of the prostate and its surrounding structures. Other MR imaging tools, such as dynamic contrast-enhanced T1-weighted imaging or diffusion-weighted imaging allow an inference of the biochemical characteristics (multiparametric MRI). Prostate cancer, which could only be diagnosed using MR imaging or lesions suspected as being prostate cancer, which are localized in the anterior aspect of the prostate and were missed with repetitive TRUS biopsy, need to undergo MR guided biopsy. Recent studies have shown a good correlation between MR imaging and histopathology of specimens collected by MR-guided biopsy. Improved lesion targeting is therefore possible with MR-guided biopsy. So far data suggest that MR-guided biopsy of the prostate is a promising alternative diagnostic tool to TRUS-guided biopsy.  相似文献   

12.

Background

Rosai–Dorfman disease (RDD) in sellar/suprasellar region is a rare intracranial disorder. The diagnostic evaluation of this condition using magnetic resonance imaging (MRI) has seldom been described previously. The purpose of our study was to describe MRI characteristics of sellar/suprasellar region RDD.

Methods

Five patients with proved sellar/suprasellar region RDD from May 2005 to March 2010 were retrospectively reviewed. All the patients had undergone magnetic resonance scanning. The number, location, signal intensity (SI), and enhancement pattern of the lesions on MRI were retrospectively evaluated.

Results

Pathological diagnosis of RDD was achieved in all 5 cases including 4 by surgery and 1 by biopsy. The most common presenting symptoms were headache (n = 4) and blurred vision (n = 3). On MRI, isolated suprasellar lesion was found in 2 cases. Suprasellar lesion combined with intrasellar, dural, intra-axial and orbital lesions was found in 3 cases. All lesions showed homogeneous isointense SI on T1-weighted images and hypointense to isointense SI on T2-weighted images except one lesion in the midbrain with slight hyperintense SI on T2-weighted images. All lesions showed homogeneous enhancement.

Conclusion

Homogenously enhancing sellar/suprasellar masses of hypointense to isointense SI on T2-weighted images are suggestive of RDD, and central hypointensity on T2-weighted images may be a specific finding. Intra-axial and extra-axial involvements may coexist with sellar/suprasellar region RDD. Although radiological findings can provide some evidence for this rare entity, differential diagnosis is still needed.  相似文献   

13.
The purpose of this study was to evaluate the accuracy of prostate cancer localization with simple visual diagnostic criteria using dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). A total of 46 consecutive patients with biopsy-proven prostate cancer underwent prostate 1.5 T MRI with pelvic phased-array coils before prostatectomy. Besides the usual T2-weighted sequences, a 30-s DCE sequence was acquired three times after gadoterate injection. On DCE images, all early enhancing lesions of the peripheral zone were considered malignant. In the central gland, only early enhancing lesions appearing homogeneous or invading the peripheral zone were considered malignant. Three readers specified the presence of cancer in 20 prostate sectors and the location of distinct tumors. Results were compared with histology; p < 0.05 was considered significant. For localization of cancer in the sectors, DCE imaging had a significantly higher sensitivity [logistic regression, odds ratio (OR): 3.9, p < 0.0001] and a slightly but significantly lower specificity (OR: 0.57, p < 0.0001). Of the tumors >0.3 cc, 50–60% and 78–81% were correctly depicted with T2-weighted and DCE imaging, respectively. For both techniques, the depiction rate of tumors >0.3 cc was significantly influenced by the Gleason score (most Gleason ≤6 tumors were overlooked), but not by the tumor volume. Conclusion: DCE-MRI using pelvic phased-array coils and simple visual diagnostic criteria is more sensitive for tumor localization than T2-weighted imaging.  相似文献   

14.
ObjectiveTo retrospectively study the performance of CT-guided biopsy of target prostate lesions at a single institution.MethodsBetween May 2016 and February 2021, we retrospectively identified all men without rectal access who underwent transgluteal CT-guided biopsy of PIRADS 4 or 5 targets detected on multiparametric MRI (n = 9). Clinical, radiological, and pathological details were collected by review of the electronic medical record, and included age, pre-biopsy prostate specific antigen (PSA) value, prior biopsy history, biopsy targeting technique and procedural details, complications, and final histologic diagnosis. Two targeting techniques were used: Localizing with anatomic landmarks or localizing with contrast enhancement.ResultsMean patient age was 69 years (range, 49–74) and mean PSA was 14.6 ng/mL (range 7–23). Four lesions were targeted using anatomic landmarks and 5 were targeted using contrast enhancement. All biopsies were technically successful and all resulted as prostate cancer. Three biopsies showed Gleason 6 cancer and 6 biopsies showed clinically significant prostate cancers with Gleason 7 or above. There were no major complications. 7 patients went on to definitive treatment with surgery or radiation.ConclusionTransgluteal CT-guided biopsy of MRI detected prostate lesions diagnoses clinically significant prostate cancer without complication and therefore should be considered for patients without a rectum.  相似文献   

15.
The purpose of this study was to determine the value of magnetic resonance imaging (MRI) for characterization of indeterminate spleen lesions in primary computed tomography (CT) of patients with blunt abdominal trauma. Twenty-five consecutive patients (8 female, 17 male, mean age 51.6?±?22.4 years) with an indeterminate spleen lesion diagnosed at CT after blunt abdominal trauma underwent MRI with T2- and T1-weighted images pre- and post-contrast material administration. MRI studies were reviewed by two radiologists. Age, gender, injury mechanism, injury severity score (ISS), management of patients, time interval between CT and MRI, and length of hospital stay were included into the analysis. Patient history, clinical history, imaging, and 2-month clinical outcome including review of medical records and telephone interviews served as reference standard. From the 25 indeterminate spleen lesions in CT, 11 (44 %) were traumatic; nine (36 %) were non-traumatic (pseudocysts, n?=?5; hemangioma, n?=?4) and five proven to represent artifacts in CT. The ISS (P?P?=?0.03) were significantly higher in patients with spleen lesions as compared with those without. All other parameters were similar among groups (all, P?>?0.05). The MRI features ill-defined lesion borders, variable signal intensity on T1- and T2-weighted images depending on the age of the hematoma, focal contrast enhancement indicating traumatic pseudoaneurysm, perilesional contrast enhancement, and edema were most indicative for traumatic spleen lesions. As compared with CT (2/25), MRI (5/25) better depicted thin subcapsular hematomas as indicator of traumatic spleen injury. In conclusion, MRI shows value for characterizing indeterminate spleen lesions in primary CT after blunt abdominal trauma.  相似文献   

16.
The purpose of the study is to evaluate the ability of Gd-enhancement and fat-suppressed MR imaging operating at midfield strength to characterize incidentally discovered adrenal masses. Sixty patients with 72 adrenal masses incidentally discovered during US or CT exams were studied with a 0.51 MR unit following clinical and laboratory evaluation. After Gd-DTPA intravenous administration a modified three-point Dixon technique was performed in all patients. This technique provided three images sets: conventional T1-weighted SE images, fat-suppressed T1-weighted images and water-suppressed T1-weighted images. Diagnosis was established by means of surgery (11 lesions), fineneedle biopsy (21 lesions) and stability on ultrasonographic follow-up for at least 1 year (range, 12–87 months) from adrenal lesion discovery (40 masses). In most of adenomas (n = 55) an homogeneous enhancement was observed on postcontrast T1WI; however, 15 out of these lesions showed a small focal spot of high intensity in Gd-enhanced fat-suppressed images. On the contrary, malignant conditions (n = 6) and pheochromocytoma (n = 1), all had inhomogeneous signal intensities which were relatively higher after Gadolinium injection as compared with the liver. The fat suppression technique demonstrated areas of bright signal intensity related to high vascularity. The performance of three observers in order to differentiate malignant from benign conditions showed sensitivity, specificity, diagnostic accuracy, positive and negative predictive values of 100, 88.5, 90, 50 and 100% on the basis of gadolinium enhancement only, by utilizing the Dixon technique. In conclusion, although Gd-enhancement and fat-suppressed sequence helped correctly differentiate among the groups of incidentally discovered adrenal masses, the degree of overlap suggests that it is still difficult to characterize individual patients. However, the modified three-point Dixon technique after contrast material administration appears to be a further capability of midfield MRI in the characterization of adrenal tissue.  相似文献   

17.

Objective

To evaluate DW MR tumour volumetry and post-CRT ADC in rectal cancer as predicting factors of CR using high b values to eliminate perfusion effects.

Methods

One hundred rectal cancer patients who underwent 1.5-T rectal MR and DW imaging using three b factors (0, 150, and 1,000 s/mm2) were enrolled. The tumour volumes of T2-weighted MR and DW images and pre- and post-CRT ADC150–1000 were measured. The diagnostic accuracy of post-CRT ADC, T2-weighted MR, and DW tumour volumetry was compared using ROC analysis.

Results

DW MR tumour volumetry was superior to T2-weighted MR volumetry comparing the CR and non-CR groups (P?<?0.001). Post-CRT ADC showed a significant difference between the CR and non-CR groups (P?=?0.001). The accuracy of DW tumour volumetry (Az?=?0.910) was superior to that of T2-weighed MR tumour volumetry (Az?=?0.792) and post-CRT ADC (Az?=?0.705) in determining CR (P?=?0.015). Using a cutoff value for the tumour volume reduction rate of more than 86.8 % on DW MR images, the sensitivity and specificity for predicting CR were 91.4 % and 80 %, respectively.

Conclusion

DW MR tumour volumetry after CRT showed significant superiority in predicting CR compared with T2-weighted MR images and post-CRT ADC.

Key Points

? Diffusion-weighted MR (DWMR) imaging offers new information about rectal cancer. ? DWMR helps to predict complete remission after chemoradiotherapy in patients with advanced rectal cancer. ? DWMR provides more accurate diagnostic information than T2-weighted MRI. ? Apparent diffusion coefficients can predict CR, but they have certain clinical limitations.  相似文献   

18.
The aim of this study was to describe the MR appearance of multifocal nodular fatty infiltration of the liver (MNFIL) using T1-weighted in-phase (IP) and opposed-phase (OP) gradient-echo as well as T2-weighted turbo-spin-echo sequences with fat suppression (FSTSE) and without (HASTE). Magnetic resonance imaging examinations at 1.5 T using T1-weighted IP and OP-GRE with fast low angle shot (FLASH) technique, and T2-weighted FSTSE, T2-weighted HASTE of 137 patients undergoing evaluation for focal liver lesions were reviewed. Five patients were identified in whom CT indicated metastatic disease; however, no liver malignancy was finally proven. Diagnosis was confirmed by biopsy (n = 3), additional wedge resection (n = 1) or follow-up MRI 6–12 months later (n = 5). Regarding the identified five patients, the number of focal liver lesions was 2 (n = 2) and more than 20 (n = 3). The MR imaging characteristics were as follows: OP-image: markedly hypointense (n = 5); IP image: isointense (n = 2) or slightly hyperintense (n = 3); T2-weighted FSTSE-image: isointense (n = 5); T2-weighted HASTE image isointense (n = 1); slightly hyperintense (n = 4). On OP images all lesions were sharply demarcated and of almost spherical configuration (n = 5). Further evaluation by histology or follow-up MR imaging did not give evidence of malignancy in any case. Histology revealed fatty infiltration of the liver parenchyma in three patients. Magnetic resonance follow-up showed complete resolution in two patients and no change in three patients. Multifocal nodular fatty infiltration can simulate metastatic disease on both CT and MR imaging. The combination of in-phase (IP) and opposed-phase (OP) gradient-echo imaging can reliably differentiate MNFIL from metastatic disease. Received: 15 September 1999 Revised: 3 February 2000; Accepted: 7 February 2000  相似文献   

19.

PURPOSE

With the increased recognition of the capabilities of prostate multiparametric (mp) magnetic resonance imaging (MRI), attempts are being made to incorporate MRI into routine prostate biopsies. In this study, we aimed to analyze the diagnostic yield via cognitive fusion, transrectal ultrasound (TRUS)-guided, and in-bore MRI-guided biopsies in biopsy-naive patients with positive findings for prostate cancer screening.

METHODS

Charts of 140 patients, who underwent transrectal prostate biopsy after the adaptation of mp-MRI into our routine clinical practice, were reviewed retrospectively. Patients with previous negative biopsies (n=24) and digital rectal examination findings suspicious for ≥cT3 prostate cancer (n=16) were excluded. T2-weighted imaging, diffusion-weighted imaging, and dynamic contrast-enhanced imaging were included in mp-MRI. Cognitive fusion biopsies were performed after a review of mp-MRI data, whereas TRUS-guided biopsies were performed blinded to MRI information. In-bore biopsies were conducted by means of real-time targeting under MRI guidance.

RESULTS

Between January 2012 and February 2014, a total of 100 patients fulfilling the inclusion criteria underwent TRUS-guided (n=37), cognitive fusion (n=49), and in-bore (n=14) biopsies. Mean age, serum prostate specific antigen level, and prostate size did not differ significantly among the study groups. In TRUS-guided biopsy group, 51.3% were diagnosed with prostate cancer, while the same ratio was 55.1% and 71.4% in cognitive fusion and in-bore biopsy groups, respectively (P = 0.429). Clinically significant prostate cancer detection rate was 69.1%, 70.3%, and 90% in TRUS-guided, cognitive fusion, and in-bore biopsy groups, respectively (P = 0.31). According to histopathologic variables in the prostatectomy specimen, significant prostate cancer was detected in 85.7%, 93.3%, and 100% of patients in TRUS-guided, cognitive fusion, and in-bore biopsy groups, respectively.

CONCLUSION

In the first set of transrectal prostate biopsies, mp-MRI guidance did not increase the diagnostic yield significantly.Transrectal ultrasound-guided prostate biopsy (TRUS-guided) to diagnose prostate cancer is currently estimated to be performed in one million men annually in the USA (1). The original random systematic, six-core transrectal prostate biopsy, initially described by Stamey in 1989 (2), has incorporated more cores over time, with laterally directed 12–14 cores being an accepted practice standard. The major limitation of random systematic sampling is that; clinically insignificant cancers are often identified by chance and affect survival data due to lead and length time bias from overdetection and overtreatment of indolent disease (3). Unlike the diagnostic pathways for other organ cancers, which include direct visual or radiologic guidance, the prostate is being sampled by way of standardized, systematic but essentially random approaches.With the aid of multiparametric MRI of the prostate (mp-MRI), clinically relevant localized prostate cancer foci may be identified, selectively sampled, and treated (46). Hence attempts are being made to incorporate mp-MRI into routine prostate biopsies. Techniques of MRI-targeted biopsy include visual estimation TRUS-guided biopsy (cognitive fusion); software co-registered MRI-ultrasound TRUS-guided biopsy; and in-bore MRI-guided biopsy.MRI-guided prostate biopsies are particularly useful in the setting of ongoing clinical suspicion of prostate cancer despite previous negative biopsies. Among men with a previous negative biopsy, 72% to 87% of cancers detected by MRI-guidance are clinically significant (7). Likewise, mp-MRI findings can also be utilized to cognitively tailor the initial transrectal prostate biopsy protocol. Among men with no previous biopsy, MRI increases the frequency of significant cancer detection to 50% in low risk and 71% in high risk patients (7).In this study, we aimed to compare the diagnostic efficiency of cognitive fusion, TRUS-guided and in-bore biopsies, which were conducted as the initial sampling modality, in terms of detecting clinically significant prostate cancer.  相似文献   

20.
ObjectiveTo describe the multiparametric magnetic resonance imaging (MRI) appearance of prostate tuberculosis.ResultsThe histopathological results were obtained from biopsies in four men and from transurethral resection of the prostate in two men after the MRI examination. Nodular (33%, 2/6 patients) and diffuse lesions (67%, 4/6 patients) were seen on MRI. The nodular lesions were featured by extremely low signal intensity (similar to that of muscle) on T2-weighted imaging (T2WI). The T2WI signal intensity of the diffuse lesions was low but higher than that of muscle, which showed high signal intensity on diffusion weighted imaging and low signal intensity on an apparent diffusion coefficient map. MR spectroscopic imaging of this type showed a normal-like spectrum. Abscesses were found in one patient with the nodular type and in one with the diffuse type.ConclusionThe appearance of prostate tuberculosis on MRI can be separated into multiple nodular and diffuse types. Multiparametric MRI may offer useful information for diagnosing prostate tuberculosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号