Objective

To compare the diagnostic performance of light emitting diode (LED) backlight monitors and cold cathode fluorescent lamp (CCFL) monitors for the interpretation of digital chest radiographs.

Materials and Methods

We selected 130 chest radiographs from health screening patients. The soft copy image data were randomly sorted and displayed on a 3.5 M LED (2560 × 1440 pixels) monitor and a 3 M CCFL (2048 × 1536 pixels) monitor. Eight radiologists rated their confidence in detecting nodules and abnormal interstitial lung markings (ILD). Low dose chest CT images were used as a reference standard. The performance of the monitor systems was assessed by analyzing 2080 observations and comparing them by multi-reader, multi-case receiver operating characteristic analysis. The observers reported visual fatigue and a sense of heat. Radiant heat and brightness of the monitors were measured.

Results

Measured brightness was 291 cd/m2 for the LED and 354 cd/m2 for the CCFL monitor. Area under curves for nodule detection were 0.721 ± 0.072 and 0.764 ± 0.098 for LED and CCFL (p = 0.173), whereas those for ILD were 0.871 ± 0.073 and 0.844 ± 0.068 (p = 0.145), respectively. There were no significant differences in interpretation time (p = 0.446) or fatigue score (p = 0.102) between the two monitors. Sense of heat was lower for the LED monitor (p = 0.024). The temperature elevation was 6.7℃ for LED and 12.4℃ for the CCFL monitor.

Conclusion

Although the LED monitor had lower maximum brightness compared with the CCFL monitor, soft copy reading of the digital chest radiographs on LED and CCFL showed no difference in terms of diagnostic performance. In addition, LED emitted less heat.  相似文献   

2.

Objective

To investigate the correlation between radiologic vascular dilatation and serum nitrite concentration and eNOS expression in the endothelial cell and pneumocyte in a rabbit model of hepatopulmonary syndrome induced by common bile duct ligation (CBDL).

Materials and Methods

Thin-section CT scans of the lung and pulmonary angiography were obtained 3 weeks after CBDL (n=6), or a sham operation (n=4), and intrapulmonary vasodilatation was assessed. The diameter and tortuosity of peripheral vessels in the right lower lobe by thin-section CT and angiography at the same level of the right lower lobe in all subjects were correlated to serum nitrite concentration and eNOS (endothelial nitric oxide synthase) expression as determined by immunostaining.

Results

The diameters of pulmonary vessels on thin-section CT were well correlated with nitrite concentrations in serum (r = 0.92, p < 0.001). Dilated pulmonary vessels were significantly correlated with an increased eNOS expression (r = 0.94, p < 0.0001), and the severity of pulmonary vessel tortuosity was found to be well correlated with serum nitrite concentration (r = 0.90, p < 0.001).

Conclusion

The peripheral pulmonary vasculature in hepatopulmonary syndrome induced by CBLD was dilated on thin-section CT and on angiographs. Our findings suggest that peripheral pulmonary vascular dilatations are correlated with serum nitrite concentrations and pulmonary eNOS expression.  相似文献   

3.

Objective

To assess the feasibility and safety of CT-guided percutaneous transthoracic radiofrequency ablation (RFA) with saline infusion of pulmonary tissue in rabbits.

Materials and Methods

Twenty-eight New Zealand White rabbits were divided into two groups: an RFA group (n=10) and a saline-enhanced RFA (SRFA) group (n=18). In the RFA group, percutaneous RFA of the lung was performed under CT guidance and using a 17-gauge internally cooled electrode. In the SRFA group, 1.5 ml of 0.9% saline was infused slowly through a 21-gauge, polyteflon-coated Chiba needle prior to and during RFA. Lesion size and the healing process were studied in rabbits sacrificed at times from the day following treatment to three weeks after, and any complications were noted.

Results

In the SRFA group, the mean diameter (12.5 ± 1.6 mm) of acute RF lesions was greater than that of RFA lesions (8.5 ± 1.4 mm) (p < .05). The complications arising in 12 cases were pneumothorax (n=8), thermal injury to the chest wall (n=2), hemothorax (n=1), and lung abscess (n=1). Although procedure-related complications tended to occur more frequently in the SRFA group (55.6%) than in the RFA group (20%), the difference was not statistically significant (p = .11).

Conclusion

Saline-enhanced RFA of pulmonary tissue in rabbits produces more extensive coagulation necrosis than conventional RFA procedures, without adding substantial risk of serious complications.  相似文献   

4.

Objective

To evaluate the effect of computer-aided detection (CAD) system on observer performance in the detection of malignant lung nodules on chest radiograph.

Materials and Methods

Two hundred chest radiographs (100 normal and 100 abnormal with malignant solitary lung nodules) were evaluated. With CT and histological confirmation serving as a reference, the mean nodule size was 15.4 mm (range, 7-20 mm). Five chest radiologists and five radiology residents independently interpreted both the original radiographs and CAD output images using the sequential testing method. The performances of the observers for the detection of malignant nodules with and without CAD were compared using the jackknife free-response receiver operating characteristic analysis.

Results

Fifty-nine nodules were detected by the CAD system with a false positive rate of 1.9 nodules per case. The detection of malignant lung nodules significantly increased from 0.90 to 0.92 for a group of observers, excluding one first-year resident (p = 0.04). When lowering the confidence score was not allowed, the average figure of merit also increased from 0.90 to 0.91 (p = 0.04) for all observers after a CAD review. On average, the sensitivities with and without CAD were 87% and 84%, respectively; the false positive rates per case with and without CAD were 0.19 and 0.17, respectively. The number of additional malignancies detected following true positive CAD marks ranged from zero to seven for the various observers.

Conclusion

The CAD system may help improve observer performance in detecting malignant lung nodules on chest radiographs and contribute to a decrease in missed lung cancer.  相似文献   

5.

Objective

We wanted to determine the clinical feasibility of using non-breath-hold real-time MR-echo imaging for the evaluation of mediastinal and chest wall tumor invasion.

Materials and Methods

MR-echo imaging was prospectively applied to 45 structures in 22 patients who had non-small cell lung cancer when the tumor invasion was indeterminate on CT. The static MR imaging alone, and the static MR imaging combined with MR-echo examinations were analyzed. The surgical and pathological findings were compared with using the Wilcoxon-signed rank test and McNemar''s test.

Results

The accuracy, sensitivity and specificity of the combined MR-echo examination and static MR imaging for determining the presence of invasion were 84%, 83% and 85%, respectively, for the first reading session and they were 87%, 83% and 87%, respectively, for the second reading session (there was substantial interobserver agreement, k = 0.74). For the static MR imaging alone, these values were 62%, 83% and 59%, respectively, for the first reader and they were 69%, 67% and 74%, respectively, for the second reader (there was moderate interobserver agreement, k = 0.49). The diagnostic confidence for tumor invasion was also higher for the combined MR-echo examination and static MR imaging than that for the static MR imaging alone (p < 0.05).

Conclusion

The combined reading of a non-breath-hold real-time MR-echo examination and static MR imaging provides higher specificity and diagnostic confidence than those for the static MR imaging reading alone to determine the presence of mediastinal or chest wall tumor invasion when this was indeterminate on CT scanning.  相似文献   

6.

Objective

We observed patients in whom the fluid collection in the right lateral portion of the superior aortic recess on computed tomography (CT) scans mimicked a right anterior mediastinal mass on chest PA radiographs. The purpose of this study was to assess chest PA and CT features of these patients.

Materials and Methods

All chest PA radiographs and CT scans in 9 patients were reviewed by two radiologists on a consensus basis; for the presence of pleural effusion, pulmonary edema and heart size on chest PA radiographs. For the portion of the fluid collection in the superior aortic recess (SAR), a connection between the right lateral portion of the SAR (rSAR) and posterior portion of the SAR (pSAR) on CT scans, and the distance between the right lateral margin of the rSAR and the right lateral margin of the superior vena cava.

Results

Fluid collection in the rSAR on CT scans caused a right anterior mediastinal mass or a bulging contour on chest PA radiographs in all women patients. All patients showed cardiomegaly, five patients had pleural effusion, and two patients had mild pulmonary edema. Further, eight patients showed a connection between the rSAR and the pSAR.

Conclusion

The characteristic features of these patients are the right anterior mediastinal mass-like opacity due to fluid collection in the rSAR, are bulging contour with a smooth margin and cardiomegaly regardless of pulmonary edema on the chest PA radiographs, and fluid connection between the rSAR and the pSAR on CT scans.  相似文献   

7.

Objective

The purpose of this study was to review the clinical and radiographic features of solitary and COD-associated SBCs.

Methods

Archived imaging reports from the Special Procedures Clinic in Oral and Maxillofacial Radiology at the Faculty of Dentistry at the University of Toronto between 1 January 1989 and 31 December 2009 revealed 23 COD-associated SBCs and 68 solitary SBCs.

Results

Almost all solitary and COD-associated SBCs were found in the mandible. Furthermore, 87.0% of COD-associated SBCs were found in females in their fifth decade of life (P < 0.001) while solitary SBCs were found in equal numbers in both sexes in their second decade of life (P < 0.005). COD-associated SBCs were also more likely to cause thinning of the endosteal cortex, bone expansion and scalloping of the superior border between teeth (all P < 0.001) than solitary SBCs that are classically described as having these characteristics. Finally, COD-associated SBC demonstrated a loss of lamina dura more often (P < 0.05) than solitary SBCs.

Conclusions

Knowledge of the sporadic association between COD and SBC and their potential radiographic appearances should prevent inappropriate treatment and management of these patients.  相似文献   

8.

Objective

The aim of this study was to use fractal dimension (FD) analysis on multidetector CT (MDCT) images for quantifying the morphological changes of the pulmonary artery tree in patients with pulmonary hypertension (PH).

Materials and Methods

Fourteen patients with PH and 17 patients without PH as controls were studied. All of the patients underwent contrast-enhanced helical CT and transthoracic echocardiography. The pulmonary artery trees were generated using post-processing software, and the FD and projected image area of the pulmonary artery trees were determined with ImageJ software in a personal computer. The FD, the projected image area and the pulmonary artery pressure (PAP) were statistically evaluated in the two groups.

Results

The FD, the projected image area and the PAP of the patients with PH were higher than those values of the patients without PH (p < 0.05, t-test). There was a high correlation of FD with the PAP (r = 0.82, p < 0.05, partial correlation analysis). There was a moderate correlation of FD with the projected image area (r = 0.49, p < 0.05, partial correlation analysis). There was a correlation of the PAP with the projected image area (r = 0.65, p < 0.05, Pearson correlation analysis).

Conclusion

The FD of the pulmonary arteries in the PH patients was significantly higher than that of the controls. There is a high correlation of FD with the PAP.  相似文献   

9.

Objective

To compare the clinical utility of the different imaging techniques used for the evaluation of tracheobronchial diseases.

Materials and Methods

Forty-one patients with tracheobronchial diseases [tuberculosis (n = 18), bronchogenic carcinoma (n = 10), congenital abnormality (n = 3), post-operative stenosis (n = 2), and others (n = 8)] underwent chest radiography and spiral CT. Two sets of scan data were obtained: one from routine thick-section axial images and the other from thin-section axial images. Multiplanar reconstruction (MPR) and shaded surface display (SSD) images were obtained from thin-section data. Applying a 5-point scale, two observers compared chest radiography, routine CT, thin-section spiral CT, MPR and SSD imaging with regard to the detection, localization, extent, and characterization of a lesion, information on its relationship with adjacent structures, and overall information.

Results

SSD images were the most informative with regard to the detection (3.95±0.31), localization (3.95±0.22) and extent of a lesion (3.85±0.42), and overall information (3.83±0.44), while thin-section spiral CT scans provided most information regarding its relationship with adjacent structures (3.56±0.50) and characterization of the lesion (3.51±0.61).

Conclusion

SSD images and thin-section spiral CT scans can provide valuable information for the evaluation of tracheobronchial disease.  相似文献   

10.

Objective

To investigate radiation doses in pediatric chest radiography in a national survey and to analyze the factors that affect radiation doses.

Materials and Methods

The study was based on the results of 149 chest radiography machines in 135 hospitals nationwide. For each machine, a chest radiograph was obtained by using a phantom representing a 5-year-old child (ATOM® dosimetry phantom, model 705-D, CIRS, Norfolk, VA, USA) with each hospital''s own protocol. Five glass dosimeters (M-GD352M, Asahi Techno Glass Corporation, Shizuoka, Japan) were horizontally installed at the center of the phantom to measure the dose. Other factors including machine''s radiography system, presence of dedicated pediatric radiography machine, presence of an attending pediatric radiologist, and the use of automatic exposure control (AEC) were also evaluated.

Results

The average protocol for pediatric chest radiography examination in Korea was 94.9 peak kilovoltage and 4.30 milliampere second. The mean entrance surface dose (ESD) during a single examination was 140.4 microgray (µGy). The third quartile, median, minimum and maximum value of ESD were 160.8 µGy, 93.4 µGy, 18.8 µGy, and 2334.6 µGy, respectively. There was no significant dose difference between digital and non-digital radiography systems. The use of AEC significantly reduced radiation doses of pediatric chest radiographs (p < 0.001).

Conclusion

Our nationwide survey shows that the third quartile, median, and mean ESD for pediatric chest radiograph is 160.8 µGy, 93.4 µGy, and 140.4 µGy, respectively. No significant dose difference is noticed between digital and non-digital radiography systems, and the use of AEC helps significantly reduce radiation doses.  相似文献   

11.

Objective

To determine the usefulness of a computer-aided diagnosis (CAD) system for the automated detection of lung nodules at low-dose CT.

Materials and Methods

A CAD system developed for detecting lung nodules was used to process the data provided by 50 consecutive low-dose CT scans. The results of an initial report, a second look review by two chest radiologists, and those obtained by the CAD system were compared, and by reviewing all of these, a gold standard was established.

Results

By applying the gold standard, a total of 52 nodules were identified (26 with a diameter ≤ 5 mm; 26 with a diameter > 5 mm). Compared to an initial report, four additional nodules were detected by the CAD system. Three of these, identified only at CAD, formed part of the data used to derive the gold standard. For the detection of nodules > 5 mm in diameter, sensitivity was 77% for the initial report, 88% for the second look review, and 65% for the CAD system. There were 8.0±5.2 false-positive CAD results per CT study.

Conclusion

These preliminary results indicate that a CAD system may improve the detection of pulmonary nodules at low-dose CT.  相似文献   

12.

Objective

To analyze the plain chest radiographic and CT findings of superficial endobronchial lung cancer and to correlate these with the findings of histopathology.

Materials and Methods

This study involved 19 consecutive patients with pathologically proven lung cancer confined to the bronchial wall. Chest radiographs and CT scans were reviewed for the presence of parenchymal abnormalities, endobronchial nodules, bronchial obstruction, and bronchial wall thickening and stenosis. The CT and histopathologic findings were compared.

Results

Sixteen of the 19 patients had abnormal chest radiographic findings, while in 15 (79%), CT revealed bronchial abnormalities: an endobronchial nodule in seven, bronchial obstruction in five, and bronchial wall thickening and stenosis in three. Histopathologically, the lesions appeared as endobronchial nodules in 11 patients, irregular thickening of the bronchial wall in six, elevated mucosa in one, and carcinoma in situ in one.

Conclusion

CT helps detect superficial endobronchial lung cancer in 79% of these patients, though there is some disagreement between the CT findings and the pathologic pattern of bronchial lesions. Although nonspecific, findings of bronchial obstruction or bronchial wall thickening and stenosis should not be overlooked, and if clinically necessary, bronchoscopy should be performed.  相似文献   

13.

Objective

This study was designed to describe the radiological findings of extensively drug-resistant (XDR) pulmonary tuberculosis (TB) and to compare the observed findings with findings of drug-sensitive (DS) and non-XDR multidrug-resistant (MDR) TB in non-AIDS patients.

Materials and Methods

From September 1994 to December 2007, 53 MDR TB patients (M:F = 32:21; mean age, 38 years) and 15 XDR TB non-AIDS patients (M:F = 8:7; mean age, 36 years) were enrolled in the study. All of the MDR TB patients had received no treatment or less than one month of anti-TB treatment. In addition, all XDR TB patients received either no anti-TB treatment or only first-line anti-TB drugs. In addition, 141 consecutive DS TB patients (M:F = 79:62; mean age, 51 years) were also enrolled in the study for comparison. Chest radiograph, CT and demographic findings were reviewed and were compared among the three patient groups.

Results

For patients with XDR TB, the most frequent radiographic abnormalities were nodules (15 of 15 patients, 100%), reticulo-nodular densities (11 of 15, 73%), consolidation (9 of 15, 60%) and cavities (7 of 15, 47%) that were located mainly in the upper and middle lung zones. As seen on radiographs, significant differences were found for the frequency of nodules and ground-glass opacity lesions (all p < 0.001) (more frequent in DS TB patients than in MDR and XDR TB patients). For the use of CT, significant differences (more frequent in MDR and XDR TB patients) were found for the frequency of multiple cavities, nodules and bronchial dilatation (p = 0.001 or p < 0.001). Patients with MDR TB and XDR TB were younger as compared to patients with DS TB (p < 0.001). Imaging findings were not different between patients with MDR TB and XDR TB.

Conclusion

By observation of multiple cavities, nodules and bronchial dilatation as depicted on CT in young patients with acid-fast bacilli (AFB) positive sputum, the presence of MDR TB or XDR TB rather than DS TB can be suggested. There is no significant difference in imaging findings between patients with XDR TB and MDR TB.  相似文献   

14.

Objectives

The purpose of this study was to determine the accuracy and effectiveness of digital panoramic radiographs for pre-operative assessment of dental implants.

Methods

We selected 86 patients (221 implants) and calculated the length of the planned implant based on the distance between a selection of critical anatomical structures and the alveolar crest using the scaling tools provided in the digital panoramic system. We analysed the magnification rate and the difference between the actual inserted implant length and planned implant length according to the location of the implant placement and the clarity of anatomical structures seen in the panoramic radiographs.

Results

There was no significant difference between the planned implant length and actual inserted implant length (P > 0.05). The magnification rate of the width and length of the inserted implants, seen in the digital panoramic radiographs, was 127.28 ± 13.47% and 128.22 ± 4.17%, respectively. The magnification rate of the implant width was largest in the mandibular anterior part and there was a significant difference in the magnification rate of the length of implants between the maxilla and the mandible (P < 0.05). When the clarity of anatomical structures seen in the panoramic radiographs is low, the magnification rate of the width of the inserted implants is significantly higher (P < 0.05), but there is no significant difference between the planned implant length and actual inserted implant length according to the clarity of anatomical structures (P < 0.05).

Conclusions

Digital panoramic radiography can be considered a simple, readily available and considerably accurate pre-operative assessment tool in the vertical dimension for dental implant therapy.  相似文献   

15.

Background

Fatigue and impaired performance in athletes is well recognised and has been loosely linked to “overtraining”. Reduced concentration of IgA in the saliva and increased shedding of Epstein Barr virus (EBV) have been associated with intense training in elite athletes.

Objective

To determine whether athletes presenting with fatigue and impaired performance had an immune defect relevant to defective containment of EBV infection, and whether a probiotic preparation (Lactobacillus acidophilus) shown to enhance mucosal immunity in animal models could reverse any detected abnormality.

Results

The fatigued athletes had clinical characteristics consistent with re‐activation of EBV infection and significantly (p  =  0.02) less secretion of interferon (IFN) γ from blood CD4 positive T cells. After one month of daily capsules containing 2 × 1010 colony forming units of L acidophilus, secretion of IFNγ from T cells had increased significantly (p  =  0.01) to levels found in healthy control athletes. A significant (p  =  0.03) increase in salivary IFNγ concentrations in healthy control athletes after the one month course of L acidophilus demonstrated in man the capacity for this probiotic to enhance the mucosal IFNγ concentration.

Conclusion

This is the first evidence of a T cell defect in fatigued athletes, and of its reversal following probiotic therapy.  相似文献   

16.

Objectives

To assess the accuracy of radiographic measurements of infrabony defects and to compare the accuracy with and without individual digital adjustment of brightness and contrast.

Methods

In 41 periodontitis patients (19 females, 22 males; age range 23–73 years), 50 radiographs of 50 infrabony defects were obtained. All radiographs were digitized. Using a personal computer program, the linear distances between cemento-enamel junction (CEJ) and alveolar crest (AC) and between CEJ and bony defect (BD), and the depth of the infrabony defect (INFRA), were measured twice, according to the individual judgement of the radiographic examiner: (1) without digital adjustment (W) and (2) after use of contrast and brightness adjustment (A). Intrasurgical bone measurements served as the gold standard. The accuracy of measurements with or without digital adjustment was compared.

Results

Radiographic measurements underestimated the gold standard for CEJ-BD (W: 1.1 mm ± 1.8 mm, P < 0.001; A: 1.0 mm ± 1.9 mm, P = 0.001). Both CEJ-AC (W: 0.2 mm ± 2.5 mm; A: 0.5 mm ± 2.6 mm) and INFRA (W: −0.4 mm ± 2.4 mm; A: −0.6 mm ± 2.5 mm) measurements came close to the gold standard. Statistically significant differences between W and A regarding accuracy were not observed.

Conclusions

The measurement tool used in this study provided high-accuracy measurements of periodontal bone loss in INFRA. Individual brightness and contrast adjustment failed to improve accuracy.  相似文献   

17.

Objective

To determine whether the introducer curving technique is useful in decreasing the degree of tilting of transfemoral Tulip filters.

Materials and Methods

The study sample group consisted of 108 patients with deep vein thrombosis who were enrolled and planned to undergo thrombolysis, and who accepted transfemoral Tulip filter insertion procedure. The patients were randomly divided into Group C and Group T. The introducer curving technique was Adopted in Group T. The post-implantation filter tilting angle (ACF) was measured in an anteroposterior projection. The retrieval hook adhering to the vascular wall was measured via tangential cavogram during retrieval.

Results

The overall average ACF was 5.8 ± 4.14 degrees. In Group C, the average ACF was 7.1 ± 4.52 degrees. In Group T, the average ACF was 4.4 ± 3.20 degrees. The groups displayed a statistically significant difference (t = 3.573, p = 0.001) in ACF. Additionally, the difference of ACF between the left and right approaches turned out to be statistically significant (7.1 ± 4.59 vs. 5.1 ± 3.82, t = 2.301, p = 0.023). The proportion of severe tilt (ACF ≥ 10°) in Group T was significantly lower than that in Group C (9.3% vs. 24.1%, χ2 = 4.267, p = 0.039). Between the groups, the difference in the rate of the retrieval hook adhering to the vascular wall was also statistically significant (2.9% vs. 24.2%, χ2 = 5.030, p = 0.025).

Conclusion

The introducer curving technique appears to minimize the incidence and extent of transfemoral Tulip filter tilting.  相似文献   

18.

Objective

We wanted to describe the findings of simple pulmonary eosinophilia with using 18 fluorodeoxyglucose (FDG) positron emission tomography (PET).

Materials and Methods

We analysed the findings of 14 patients who underwent thoracic computed tomography (CT) and PET, and then they were subsequently proven to have simple pulmonary eosinophilia. PET studies were performed in four patients with malignancy to evaluate for cancer metastasis, and PET scans were also done in 10 healthy subjects who underwent volunteer cancer screening. The PET scans were evaluated by using the maximum standardized uptake values (SUVs). The subjects'' CT findings also were reviewed and correlated with the PET findings.

Results

A total of 42 nodules were detected on the CT scans. There were single nodules in three patients and multiple nodules in 11 patients (mean number of nodules: 3, range: 1-10, mean diameter: 9.5 mm ± 4.7). Twelve of 42 (28.6%) nodules showed FDG uptake and their mean maximum SUV was 2.5 ± 1.6 (range: 0.6-5.3). Five of six solid nodules showed FDG uptake (2.2 ± 1.1, range: 0.9-3.6), six of 11 semisolid nodules showed FDG uptake (3.1 ± 1.8, range: 0.6-5.3) and one of 25 pure ground-glass opacity nodule showed a maximum SUV of 0.8. The maximum SUVs of seven nodules in five patients were greater than 2.5. The maximum SUVs were significantly different according to the nodule types (p < 0.001).

Conclusion

Simple pulmonary eosinophilia commonly causes an increase in FDG uptake. Therefore, correlation of the PET findings with the CT findings or the peripheral eosinophil counts can help physicians arrive at the correct diagnosis of simple pulmonary eosinophilia.  相似文献   

19.

Objective

To describe the radiologic findings of migrating lobar atelectasis of the right lung.

Materials and Methods

Chest radiographs (n = 6) and CT scans (n = 5) of six patients with migrating lobar atelectasis of the right lung were analyzed retrospectively. The underlying diseases associated with lobar atelectasis were bronchogenic carcinoma (n = 4), bronchial tuberculosis (n = 1), and tracheobronchial amyloidosis (n = 1).

Results

Atelectasis involved the right upper lobe (RUL) (n = 3) and both the RUL and right middle lobe (RML) (n = 3). On supine anteroposterior radiographs (n = 5) and on an erect posteroanterior radiograph (n = 1), the atelectatic lobe(s) occupied the right upper lung zone, with a wedge shape abutting onto the right mediastinal border. On erect posteroanterior radiographs (n = 6), the heavy atelectatic lobe(s) migrated downward, forming a peri- or infrahilar area of increased opacity and obscuring the right cardiac margin. Erect lateral radiographs (n = 4) showed inferior shift of the anterosuperiorly located atelectatic lobe(s) to the anteroinferior portion of the hemithorax.

Conclusion

Atelectatic lobe(s) can move within the hemithorax according to changes in a patient''s position. This process involves the RUL or both the RUL and RML.  相似文献   

20.

Objective

To evaluate the postoperative laryngeal CT findings of neoarytenoid soft tissue at an arytenoidectomy site during a supracricoid partial laryngectomy, and to compare its thickness to the mucosa over the spared arytenoid cartilage.

Materials and Methods

Thirty-one patients underwent a supracricoid partial laryngectomy with (n = 14) or without (n = 17) an arytenoidectomy. A postoperative laryngeal CT examination was performed to statistically compare the thickness of the neoarytenoid soft tissue to the mucosa over the spared arytenoids.

Results

The neoarytenoid soft tissue revealed an eccentric prominence in all 14 arytenoidectomy sites. Further, the neoarytenoid soft tissue was consistently thicker than the mucosa over spared arytenoids cartilage (p < 0.01), however did not exceed 11 mm.

Conclusion

The eccentric prominence of neoarytenoid soft tissue at the arytenoidectomy site during a supracricoid partial laryngectomy should be identified and distinguished from a recurrent mass when compared to spared arytenoid cartilage on a postoperative laryngeal CT.  相似文献   