Jeong Min Lee Joon Koo Han Se Hyung Kim Kyu Li Sohn Kyoung Ho Lee Su Kyung Ah Byung Ihn Choi 《Korean journal of radiology》2003,4(3):163-169
Objective
To compare the in-vitro efficiency of a hypertonic saline (HS)-enhanced bipolar radiofrequency (RF) system with monopolar RF applications by assessing the temperature profile and dimensions of RF-created coagulation necrosis in bovine liver.Materials and Methods
A total of 27 ablations were performed in explanted bovine livers. After placement of two 16-gauge open-perfused electrodes at an interelectrode distance of 3 cm, 5% HS was instilled into tissue at a rate of 1 mL/min through the electrode. Seventeen thermal ablation zones were created in the monopolar mode (groups A, B), and ten more were created using the two open-perfused electrodes in the bipolar mode (group C). RF was applied to each electrode for 5 mins (for a total of 10 mins, group A) or 10 mins (for a total of 20 mins, group B) at 50W in the sequential monopolar mode, or to both electrodes for 10 min in the bipolar mode (group C). During RF instillation, we measured tissue temperature at the midpoint between the two electrodes. The dimensions of the thermal ablation zones and changes in impedance and wattage during RFA were compared between the groups.Results
With open-perfusion electrodes, the mean accumulated energy output value was lower in the bipolar mode (group C: 26675 ± 3047 Watt·s) than in the monopolar mode (group A: 28778 ± 1300 Watt·s) but the difference was not statistically significant (p > 0.05). In the bipolar mode, there were impedance rises of more than 700 Ω during RF energy application, but in the monopolar modes, impedance did not changed markedly. In the bipolar mode, however, the temperature at the mid-point between the two probes was higher (85℃) than in the monopolar modes (65℃, 80℃ for group A, B, respectively) (p < 0.05). In addition, in HS-enhanced bipolar RFA (group C), the shortest diameter at the midpoint between the two electrodes was greater than in either of the monopolar modes: 5.4 ± 5.6 mm (group A); 28.8 ± 8.2 mm (group B); 31.2 ± 7.6 mm (group C) (p < 0.05)Conclusion
Using an open perfusion system, HS-enhanced bipolar RFA more efficiently created larger areas of thermal ablation and higher tissue temperatures than monopolar RFA. 相似文献2.
Jeong Min Lee Young Kon Kim Sang Won Kim Joon Koo Han Se Hyung Kim Byung Ihn Choi 《Korean journal of radiology》2004,5(1):31-38
Objective
We wanted to determine whether combined radiofrequency ablation (RFA) and acetic acid-hypertonic saline solution (AHS) instillation can increase the extent of thermally mediated coagulation in in vivo rabbit liver tissue. We also wished to determine the optimal concentration of the solution in order to maximize its effect on extent of the RFA-induced coagulation.Materials and Methods
Forty thermal ablation zones were produced in 40 rabbits by using a 17-gauge internally cooled electrode with a 1-cm active tip under ultrasound guidance. The rabbits were assigned to one of four groups: group A: RFA alone (n=10); group B: RFA with 50% AHS instillation (n=10); group C: RFA with 25% AHS instillation (n=10); group D: RFA with 15% AHS instillation (n=10). A range of acetic acid concentrations diluted in 36% NaCl to a total volume of 1 mL were instilled into the liver before RFA. The RF energy (30 W) was applied for three minutes. After RFA, in each group, the maximum diameters of the thermal ablation zones in the gross specimens were compared. Technical success and the complications that arose were evaluated by CT and on the basis of autopsy findings.Results
All procedures are technically successful. There were six procedure-related complications (6/40; 15%): two localized perihepatic hematomas and four chemical peritonitis. The incidence of chemical peritonitis was highest for group B with the 50% AHS solution instillation (30%). With instillation of 15% AHS solution, a marked decrease of tissue impedance (24.5 ± 15.6 Ω) and an increase of current (250 mA) occurred as compared to RFA alone. With instillation of the solutions before RFA (group B, C and D), this produced a greater mean diameter of coagulation necrosis than the diameters for rabbits not instilled with the solution (group A) (p < 0.05). However, there was no significant difference between group B, C, and D.Conclusion
Combined AHS instillation and RFA can increase the dimension of coagulation necrosis in the liver with a single application. A low concentration of AHS (15%) showed similar effects in increasing the extent of RF-induced coagulation, but there were less side effects as compared to the high concentration of AHS. 相似文献3.
Jeong Min Lee Joon Koo Han Se Hyung Kim Jae Young Lee Dae Jin Kim Min Woo Lee Gyung goo Cho Chang Jin Han Byung Ihn Choi 《Korean journal of radiology》2004,5(2):121-127
Objective
To determine whether saline-enhanced dual probe bipolar radiofrequency ablation (RFA) using perfused-cooled electrodes shows better in-vitro efficiency than monopolar or single probe bipolar RFA in creating larger coagulation necrosis.Materials and Methods
RF was applied to excised bovine livers in both bipolar and monopolar modes using a 200W generator (CC-3; Radionics) and the perfused-cooled electrodes for 10 mins. After placing single or double perfused-cooled electrodes in the explanted liver, 30 ablation zones were created at three different regimens: group A; saline-enhanced monopolar RFA, group B; saline-enhanced single probe bipolar RFA, and group C; saline-enhanced dual probe bipolar RFA. During RFA, we measured the tissue temperature at 15mm from the electrode. The dimensions of the ablation zones and changes in the impedance currents and liver temperature during RFA were then compared between the groups.Results
The mean current values were higher for monopolar mode (group A) than for the bipolar modes (groups B and C): 1550±25 mA in group A, 764±189 mA in group B and 819±98 mA in group C (p < 0.05). The volume of RF-induced coagulation necrosis was greater in group C than in the other groups: 27.6±2.9 cm3 in group A, 23.7±3.8 cm3 in group B, and 34.2±5.1 cm3 in group C (p < 0.05). However, there was no significant difference between the short-axis diameter of the coagulation necrosis in the three groups: 3.1±0.8 cm, 2.9±1.2 cm and 4.0±1.3 cm in groups A, B and C, respectively (p > 0.05). The temperature at 15 mm from the electrode was higher in group C than in the other groups: 70±18℃ in group A, 59±23℃ in group B and 96±16℃ in group C (p < 0.05).Conclusion
Saline-enhanced bipolar RFA using dual perfused-cooled electrodes increases the dimension of the ablation zone more efficiently than monopolar RFA or single probe bipolar RFA. 相似文献4.
Jeong Min Lee Joon Koo Han Se Hyung Kim Jae Young Lee Kyung Sook Shin Chang Jin Han Min Woo Lee Jun Il Choi Byung Ihn Choi 《Korean journal of radiology》2004,5(4):250-257
Objective
To determine the optimized protocol for wet monopolar radiofrequency ablation (RFA) using a perfused-cooled electrode to induce coagulation necrosis in the ex vivo bovine liver.Materials and Methods
Radiofrequency was applied to excised bovine livers in a monopolar mode using a 200W generator with an internally cooled electrode (groups A and B) or a perfused-cooled electrode (groups C, D, E, and F) at maximum power (150-200 W) for 10 minutes. A total of 60 ablation zones were created with six different regimens: group A - dry RFA using intra-electrode cooling; group B - dry RFA using intra-electrode cooling and a pulsing algorithm; group C - wet RFA using only interstitial hypertonic saline (HS) infusion; group D - wet RFA using interstitial HS infusion and a pulsing algorithm; group E - wet RFA using interstitial HS infusion and intra-electrode cooling; and group F - wet RFA using interstitial HS infusion, intra-electrode cooling and a pulsing algorithm. In groups C, D, E, and F, RFA was performed with the infusion of 6% HS through the perfused cooled electrode at a rate of 2 mL/minute. During RFA, we measured the tissue temperature at a distance of 15 mm from the electrode. The dimensions of the ablation zones and the changes in impedance, currents, and liver temperature during RFA were compared between these six groups.Results
During RFA, the mean tissue impedances in groups A (243 ± 88 Ω) and C (252.5 ± 108 Ω) were significantly higher than those in groups B (85 ± 18.7 Ω), D (108.2 ± 85 Ω), E (70.0 ± 16.3 Ω), and F (66.5 ± 7 Ω) (p < 0.05). The mean currents in groups E and F were significantly higher than those in groups B and D, which were significantly higher than those in groups A and C (p < 0.05): 520 ± 425 mA in group A, 1163 ± 34 mA in group B, 652.5 ± 418 mA in group C, 842.5 ± 773 mA in group D, 1665 ± 295 mA in group E, and 1830 ± 109 mA in group F. The mean volumes of the ablation regions in groups E and F were significantly larger than those in the other groups (p < 0.05): 17.7 ± 5.6 cm3 in group A, 34.5 ± 3.0 cm3 in group B, 20.2 ± 15.6 cm3 in group C, 36.1 ± 19.5 cm3 in group D, 68.1 ± 12.4 cm3 in group E, and 79.5 ± 31 cm3 in group F. The final tissue temperatures at a distance of 15 mm from the electrode were higher in groups E and F than those in groups A, C, and D (p < 0.05): 50 ± 7.5℃ in group A, 66 ± 13.6℃ in group B, 60 ± 13.4℃ in group C, 61 ±12.7℃ in group D, 78 ± 14.2℃ in group E, and 79 ± 12.0℃ in group F.Conclusion
Wet monopolar RFA, using intra-electrode cooling and interstitial saline infusion, showed better performance in creating a large ablation zone than either dry RFA or wet RFA without intra-electrode cooling. 相似文献5.
Jeong Min Lee Sang Won Kim Chun Ai Li Ji Hyun Youk Young Kon Kim Zhewu Jin Myoung Ja Chung Mi Suk Lee 《Korean journal of radiology》2002,3(4):245-253
Objective
To assess the feasibility and safety of CT-guided percutaneous transthoracic radiofrequency ablation (RFA) with saline infusion of pulmonary tissue in rabbits.Materials and Methods
Twenty-eight New Zealand White rabbits were divided into two groups: an RFA group (n=10) and a saline-enhanced RFA (SRFA) group (n=18). In the RFA group, percutaneous RFA of the lung was performed under CT guidance and using a 17-gauge internally cooled electrode. In the SRFA group, 1.5 ml of 0.9% saline was infused slowly through a 21-gauge, polyteflon-coated Chiba needle prior to and during RFA. Lesion size and the healing process were studied in rabbits sacrificed at times from the day following treatment to three weeks after, and any complications were noted.Results
In the SRFA group, the mean diameter (12.5 ± 1.6 mm) of acute RF lesions was greater than that of RFA lesions (8.5 ± 1.4 mm) (p < .05). The complications arising in 12 cases were pneumothorax (n=8), thermal injury to the chest wall (n=2), hemothorax (n=1), and lung abscess (n=1). Although procedure-related complications tended to occur more frequently in the SRFA group (55.6%) than in the RFA group (20%), the difference was not statistically significant (p = .11).Conclusion
Saline-enhanced RFA of pulmonary tissue in rabbits produces more extensive coagulation necrosis than conventional RFA procedures, without adding substantial risk of serious complications. 相似文献6.
Jeong Hee Yoon Jeong Min Lee Eui Jin Hwang In Pyung Hwang Jeehyun Baek Joon Koo Han Byung Ihn Choi 《Korean journal of radiology》2014,15(2):235-244
Objective
To determine the in vivo efficiency of monopolar radiofrequency ablation (RFA) using a dual-switching (DS) system and a separable clustered (SC) electrode to create coagulation in swine liver.Materials and Methods
Thirty-three ablation zones were created in nine pigs using a DS system and an SC electrode in the switching monopolar mode. The pigs were divided into two groups for two experiments: 1) preliminary experiments (n = 3) to identify the optimal inter-electrode distances (IEDs) for dual-switching monopolar (DSM)-RFA, and 2) main experiments (n = 6) to compare the in vivo efficiency of DSM-RFA with that of a single-switching monopolar (SSM)-RFA. RF energy was alternatively applied to one of the three electrodes (SSM-RFA) or concurrently applied to a pair of electrodes (DSM-RFA) for 12 minutes in in vivo porcine livers. The delivered RFA energy and the shapes and dimensions of the coagulation areas were compared between the two groups.Results
No pig died during RFA. The ideal IEDs for creating round or oval coagulation area using the DSM-RFA were 2.0 and 2.5 cm. DSM-RFA allowed more efficient RF energy delivery than SSM-RFA at the given time (23.0 ± 4.0 kcal vs. 16.92 ± 2.0 kcal, respectively; p = 0.0005). DSM-RFA created a significantly larger coagulation volume than SSM-RFA (40.4 ± 16.4 cm3 vs. 20.8 ± 10.7 cm3; p < 0.001). Both groups showed similar circularity of the ablation zones (p = 0.29).Conclusion
Dual-switching monopolar-radiofrequency ablation using an SC electrode is feasible and can create larger ablation zones than SSM-RFA as it allows more RF energy delivery at a given time. 相似文献7.
Eun Sun Lee Jeong Min Lee Kyung Won Kim In Joon Lee Joon Koo Han Byung Ihn Choi 《Korean journal of radiology》2013,14(2):194-201
Objective
To determine in vivo efficacy of radiofrequency ablation (RFA) in porcine liver by using 15-gauge Octopus® (15-G Octopus®) electrodes to create a large coagulation.Materials and Methods
A total of 18 coagulations were created by using a 180-W generator and 15-G Octopus® electrodes during laparotomy, performed in 14 pigs. Coagulation necrosis was created in the pig livers by the use of one of three RFA protocols: 1) group A, monopolar RFA using a 15-G Octopus® electrode with a 5-mm inter-electrode distance (n = 4); 2) group B, monopolar RFA using a 15-G Octopus® electrode with a 10-mm inter-electrode distance (n = 6); and 3) group C, switching monopolar RFA using two 15-G Octopus® electrodes (n = 8). The energy efficiency, shape, maximum and minimum diameters (Dmx and Dmi), and the volume of the coagulation volume were measured in each group. The Summary statistics were obtained and Mann-Whitney test was were performed.Results
The mean ablated volume of each group was 49.23 cm3 in A, 64.11 cm3 in B, and 72.35 cm3 in C. The mean Dmx and Dmi values were 5.68 cm and 4.58 cm in A and 5.97 cm and 4.97 cm in B, respectively. In group C, the mean diameters of Dmx and Dmi were 6.80 cm and 5.11 cm, respectively. The mean ratios of Dmi/Dmx were 1.25, 1.20, and 1.35 in groups A, B, and C, respectively. There was one animal death during the RFA procedure, the cause of which could not be subsequently determined. However, there were no other significant, procedure-related complications during the seven-hour-delayed CT scans.Conclusion
RFA procedures using 15-G Octopus® electrodes are useful and safe for creating a large ablation in a single electrode model as well as in the multiple electrodes model. 相似文献8.
Objective
To determine whether the introducer curving technique is useful in decreasing the degree of tilting of transfemoral Tulip filters.Materials and Methods
The study sample group consisted of 108 patients with deep vein thrombosis who were enrolled and planned to undergo thrombolysis, and who accepted transfemoral Tulip filter insertion procedure. The patients were randomly divided into Group C and Group T. The introducer curving technique was Adopted in Group T. The post-implantation filter tilting angle (ACF) was measured in an anteroposterior projection. The retrieval hook adhering to the vascular wall was measured via tangential cavogram during retrieval.Results
The overall average ACF was 5.8 ± 4.14 degrees. In Group C, the average ACF was 7.1 ± 4.52 degrees. In Group T, the average ACF was 4.4 ± 3.20 degrees. The groups displayed a statistically significant difference (t = 3.573, p = 0.001) in ACF. Additionally, the difference of ACF between the left and right approaches turned out to be statistically significant (7.1 ± 4.59 vs. 5.1 ± 3.82, t = 2.301, p = 0.023). The proportion of severe tilt (ACF ≥ 10°) in Group T was significantly lower than that in Group C (9.3% vs. 24.1%, χ2 = 4.267, p = 0.039). Between the groups, the difference in the rate of the retrieval hook adhering to the vascular wall was also statistically significant (2.9% vs. 24.2%, χ2 = 5.030, p = 0.025).Conclusion
The introducer curving technique appears to minimize the incidence and extent of transfemoral Tulip filter tilting. 相似文献9.
Nitta-Seko A Nitta N Sonoda A Otani H Tsuchiya K Ohta S Takahashi M Murata K 《The British journal of radiology》2011,84(998):179-183
Objective
Using a liver tumour model we investigated whether thalidomide enhances the anti-tumour effect of transcatheter arterial embolisation (TAE).Method
First, the viability of VX2 tumour cells co-cultured with thalidomide in a 21% and 1% O2 atmosphere was assessed by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay. Second, we randomly assigned 20 rabbits bearing VX2 liver tumours to 4 groups: Group 1 (thalidomide plus TAE), Group 2 (TAE only), Group 3 (thalidomide only) and Group 4 (control). Thalidomide was orally administered for 5 days. The anti-tumour effects were assessed by the tumour proliferation rate using MRI and by immunohistochemical analysis of the area of intratumoural vessels. Analysis of variance and Tukey''s honestly significant difference test were used for statistical analysis.Results
The viability of cells grown under hypoxic and normal conditions was not significantly different, nor was there a difference among the four groups. The tumour size increased by 55.9±29.3% in Group 1, 250.6±73.3% in Group 2, 355.2±51.7% in Group 3 and 424.7±110.7% in Group 4; the difference between Group 1 and the other three groups was significant. The area of intratumour vessels in specimens was 0.22±0.28% in Group 1, 0.42±0.29% in Group 2, 1.44±1.00% in Group 3 and 6.00±2.17% in Group 4; the difference between Group 1 and the other groups was statistically significant, as was the difference between Groups 3 and 4.Conclusion
Thalidomide used in combination with TAE enhanced anti-tumour effects in rabbits bearing VX2 liver tumours. 相似文献10.
Objective
To investigate the value of spectral CT imaging in the diagnosis and classification of liver cirrhosis during the arterial phase (AP) and portal venous phase (PVP).Materials and Methods
Thirty-eight patients with liver cirrhosis (Child-Pugh class A/B/C: n = 10/14/14), and 43 patients with healthy livers, participated in this study. The researchers used abdominal spectral CT imaging during AP and PVP. Iodine concentration, derived from the iodine-based material-decomposition image and the iodine concentration ratio (ICratio) between AP and PVP, were obtained. Statistical analyses {two-sample t test, One-factor analysis of variance, and area under the receiver operating characteristic curve (A [z])} were performed.Results
The mean normalized iodine concentration (NIC) (0.5 ± 0.12) during PVP in the control group was significantly higher than that in the study group (0.4 ± 0.10 on average, 0.4 ± 0.08 for Class A, 0.4 ± 0.15 for Class B, and 0.4 ± 0.06 for Class C) (All p < 0.05). Within the cirrhotic liver group, the mean NIC for Class C during the AP (0.1 ± 0.05) was significantly higher than NICs for Classes A (0.1 ± 0.06) and B (0.1 ± 0.03) (Both p < 0.05). The ICratio in the study group (0.4 ± 0.15), especially for Class C (0.5 ± 0.14), was higher than that in the control group (0.3 ± 0.15) (p < 0.05).The combination of NIC and ICratio showed high sensitivity and specificity for differentiating healthy liver from cirrhotic liver, especially in Class C cirrhotic liver.Conclusion
Spectral CT Provides a quantitative method with which to analyze the cirrhotic liver, and shows the potential value in the classification of liver cirrhosis. 相似文献11.
Kai Sun Rui-Juan Han Li-Jun Ma Li-Jun Wang Li-Gang Li Jiu-Hong Chen 《Korean journal of radiology》2012,13(6):684-693
Objective
To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode.Materials and Methods
Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 ± 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed.Results
There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 ± 0.306 [group A] vs. 1.084 ± 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 ± 0.16 mSv in group A and 7.1 ± 1.05 mSv in group B (p = 0.001).Conclusion
In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure. 相似文献12.
Jeong Min Lee Joon Koo Han Se Hyung Kim Kyung Sook Shin Jae Young Lee Hee Sun Park Hurn Hur Byung Ihn Choi 《Korean journal of radiology》2004,5(4):258-265
Objective
We wished to compare the in-vitro efficiency of wet radiofrequency (RF) ablation with the efficiency of dry RF ablation and RF ablation with preinjection of NaCl solutions using excised bovine liver.Materials and Methods
Radiofrequency was applied to excised bovine livers in a monopolar mode for 10 minutes using a 200 W generator and a perfused-cooled electrode with or without injection or slow infusion of NaCl solutions. After placing the perfused-cooled electrode in the explanted liver, 50 ablation zones were created with five different regimens: group A; standard dry RF ablation, group B; RF ablation with 11 mL of 5% NaCl solution preinjection, group C; RF ablation with infusion of 11 mL of 5% NaCl solution at a rate of 1 mL/min, group D; RFA with 6 mL of 36% NaCl solution preinjection, group E; RF ablation with infusion of 6 mL of 36% NaCl solution at a rate of 0.5 mL/min. In groups C and E, infusion of the NaCl solutions was started 1 min before RF ablation and then maintained during RF ablation (wet RF ablation). During RF ablation, we measured the tissue temperature at 15 mm from the electrode. The dimensions of the ablation zones and changes in impedance, current and liver temperature during RF ablation were then compared between the groups.Results
With injection or infusion of NaCl solutions, the mean initial tissue impedance prior to RF ablation was significantly less in groups B, C, D, and E (43-75 Ω) than for group A (80 Ω) (p < 0.05). During RF ablation, the tissue impedance was well controlled in groups C and E, but it was often rapidly increased to more than 200 Ω in groups A and B. In group D, the impedance was well controlled in six of ten trials but it was increased in four trials (40%) 7 min after starting RF ablation. As consequences, the mean current was higher for groups C, D, and E than for the other groups: 401 ± 145 mA in group A, 287 ± 32 mA in group B, 1907 ± 96 mA in group C, 1649 ± 514 mA in group D, and 1968 ± 108 mA in group E (p < 0.05). In addition, the volumes of RF-induced coagulation necrosis were greater in groups C and E than in group D, which was greater than in groups A and B than in group E (p < 0.05); 14.3 ± 3.0 cm3 in group A; 12.4 ± 3.8 cm3 in group B; 80.9 ± 9.9 cm3 in group C; 45.3 ± 11.3 cm3 in group D and 81.6 ± 8.6 cm3 in group E. The tissue temperature measured at 15 mm from the electrode was higher in groups C, D and E than other groups (p < 0.05): 53 ± 12℃ in group A, 42 ± 2℃ in group B, 93 ± 8℃ in group C; 79 ± 12℃ in group D and 83 ± 8℃ in group E.Conclusion
Wet RF ablation with 5% or 36% NaCl solutions shows better efficiency in creating a large ablation zone than does dry RF ablation or RF ablation with preinjection of NaCl solutions. 相似文献13.
Nak Jong Seong Chang Jin Yoon Sung-Gwon Kang Jin Wook Chung Hyo-Cheol Kim Jae Hyung Park 《Korean journal of radiology》2012,13(2):195-201
Objective
Arsenic trioxide (As2O3) can be used as a possible pharmaceutical alternative that augments radiofrequency (RF) ablation by reducing tumor blood flow. The aim of this study was to assess the effect of intraarterial and intravenous administration of As2O3 on RF-induced ablation in an experimentally induced liver tumor.Materials and Methods
VX2 carcinoma was grown in the livers of 30 rabbits. As2O3 (1 mg/kg) was administered through the hepatic artery (n = 10, group A) or ear vein (n = 10, group B), 30 minutes before RF ablation (125 mA ± 35; 90 ± 5℃). As a control group, 10 rabbits were treated with RF ablation alone (group C). RF was intentionally applied to the peripheral margin of the tumor so that ablation can cover the tumor and adjacent hepatic parenchyma. Ablation areas of the tumor and adjacent parenchymal changes among three groups were compared by the Kruskal-Wallis and Mann-Whitney U test.Results
The overall ablation areas were 156 ± 28.9 mm2 (group A), 119 ± 31.7 (group B), and 92 ± 17.4 (group C, p < 0.04). The ablation area of the tumor was significantly larger in group A (73 ± 19.7 mm2) than both group B (50 ± 19.4, p = 0.02) and group C (28 ± 2.2, p < 0.01). The ratios of the tumoral ablation area to the overall ablation area were larger in group A (47 ± 10.5%) than that of the other groups (42 ± 7.3% in group B and 32 ± 5.6% in group C) (p < 0.03).Conclusion
Radiofrequency-induced ablation area can be increased with intraarterial or intravenous administration of As2O3. The intraarterial administration of As2O3 seems to be helpful for the selective ablation of the tumor. 相似文献14.
Objective
To retrospectively compare the imaging characteristics of retropharyngeal density and associated findings for Kawasaki disease with those for non-Kawasaki disease, and identify the distinguishing features which aid the CT diagnosis of Kawasaki disease with retropharyngeal low density.Materials and Methods
Among the enhanced neck CT performed in children less than 8-years old with clinical presentation of fever and cervical lymphadenopathy over a 6-year period, only cases with retropharyngeal low density (RLD) were included in this study. The 56 cases of RLD were divided into two groups; group A included cases diagnosed as Kawasaki disease (n = 34) and group B included cases diagnosed as non-Kawasaki disease (n = 22). We evaluated the CT features including the thickness of RLD and its extent into the deep neck spaces, as well as soft tissue change in the adjacent structure. We also scored the extent of RLD into the deep neck spaces and the soft tissue changes in the adjacent structure.Results
The thickness of RLD was greater in group A than in group B (group A, 6.0 ± 2.1; group B, 4.6 ± 1.5, p = 0.01). The score of the RLD extent into the deep neck spaces was significantly greater in group A than in group B (group A, 2.3 ± 1.3; group B, 0.8 ± 1.0, p < 0.01). Also, the score of the adjacent soft tissue changes was greater in group A than in group B (group A, 2.0 ± 1.1; group B, 1.0 ± 1.0, p < 0.01).Conclusion
If children present with fever and cervical lymphadenopathy that display retropharyngeal low density with extension into more deep neck spaces as well as changes in more adjacent soft tissue, the possibility of Kawasaki disease should be considered. 相似文献15.
Objectives
To assess the accuracy of radiographic measurements of infrabony defects and to compare the accuracy with and without individual digital adjustment of brightness and contrast.Methods
In 41 periodontitis patients (19 females, 22 males; age range 23–73 years), 50 radiographs of 50 infrabony defects were obtained. All radiographs were digitized. Using a personal computer program, the linear distances between cemento-enamel junction (CEJ) and alveolar crest (AC) and between CEJ and bony defect (BD), and the depth of the infrabony defect (INFRA), were measured twice, according to the individual judgement of the radiographic examiner: (1) without digital adjustment (W) and (2) after use of contrast and brightness adjustment (A). Intrasurgical bone measurements served as the gold standard. The accuracy of measurements with or without digital adjustment was compared.Results
Radiographic measurements underestimated the gold standard for CEJ-BD (W: 1.1 mm ± 1.8 mm, P < 0.001; A: 1.0 mm ± 1.9 mm, P = 0.001). Both CEJ-AC (W: 0.2 mm ± 2.5 mm; A: 0.5 mm ± 2.6 mm) and INFRA (W: −0.4 mm ± 2.4 mm; A: −0.6 mm ± 2.5 mm) measurements came close to the gold standard. Statistically significant differences between W and A regarding accuracy were not observed.Conclusions
The measurement tool used in this study provided high-accuracy measurements of periodontal bone loss in INFRA. Individual brightness and contrast adjustment failed to improve accuracy. 相似文献16.
Tae Jin Yun Hak Jong Lee Seung Hyup Kim Sang Eun Lee Seok-Soo Byun Sung Kyu Hong Jeong Yeon Cho Chang Kyu Seong 《Korean journal of radiology》2007,8(3):231-235
Objective
We wanted to assess the relationship between pain and the prostate volume during transrectal ultrasound (TRUS) guided biopsy.Materials and Methods
Between July and September 2006, 71 patients scheduled for TRUS biopsy of the prostate were considered for inclusion to this study. These patients underwent periprostatic neurovascular bundle block with lidocaine prior to biopsy. Pain was assessed using a Visual Analogue Scale (VAS) during periprostatic neurovascular bundle block (VAS 1), during biopsy (VAS 2), and 20 minutes after biopsy (VAS 3). The mean pain scores were analyzed in the large prostate group (prostate volume > 40 cc) and the small prostate group (prostate volume ≤ 40 cc). P values < 0.05 were considered significant.Results
The mean prostate volume was 42.2 cc (standard deviation: 8.6). The mean pain scores of VAS 1, 2 and 3 were 4.70 ± 1.61, 3.15 ± 2.44 and 1.05 ± 1.51, respectively. In the large prostate group, the mean pains scores of VAS 1, 2 and 3 were 4.75 ± 1.76, 3.51 ± 2.76 and 1.29 ± 1.70, respectively, whereas in the small prostate group, the means pain scores were 4.66 ± 1.46, 2.77 ± 2.0, and 0.80 ± 1.26, respectively. Although there were no statistical differences of VAS 1, the larger prostate group revealed higher pain scores of VAS 2 and 3 compared with the small prostate group (p < 0.05).Conclusion
Patients with larger prostate volumes tend to feel more pain during and after TRUS guided prostate biopsy. Our findings suggest that additional analgesic strategies may be necessary when the patients with larger prostate undergo TRUS guided prostate biopsy. 相似文献17.
Jung Lee Jeong Min Lee Jung-Hwan Yoon Jae Young Lee Se Hyung Kim Jeong Eun Lee Joon Koo Han Byung Ihn Choi 《Korean journal of radiology》2012,13(1):34-43
Objective
To prospectively evaluate the safety and short-term therapeutic efficacy of switching monopolar radiofrequency ablation (RFA) with multiple electrodes to treat medium-sized (3.1-5.0 cm), hepatocellular carcinomas (HCC).Materials and Methods
In this prospective study, 30 patients with single medium-sized HCCs (mean, 3.5 cm; range, 3.1-4.4 cm) were enrolled. The patients were treated under ultrasonographic guidance by percutaneous switching monopolar RFA with a multichannel RF generator and two or three internally cooled electrodes. Contrast-enhanced CT scans were obtained immediately after RFA, and the diameters and volume of the ablation zones were then measured. Follow-up CT scans were performed at the first month after ablation and every three months thereafter. Technical effectiveness, local progression and remote recurrence of HCCs were determined.Results
There were no major immediate or periprocedural complications. However, there was one bile duct stricture during the follow-up period. Technical effectiveness was achieved in 29 of 30 patients (97%). The total ablation time of the procedures was 25.4 ± 8.9 minutes. The mean ablation volume was 73.8 ± 56.4 cm3 and the minimum diameter was 4.1 ± 7.3 cm. During the follow-up period (mean, 12.5 months), local tumor progression occurred in three of 29 patients (10%) with technical effectiveness, while new HCCs were detected in six of 29 patients (21%).Conclusion
Switching monopolar RFA with multiple electrodes in order to achieve a sufficient ablation volume is safe and efficient. This method also showed relatively successful therapeutic effectiveness on short-term follow up for the treatment of medium-sized HCCs. 相似文献18.
Joo Yeon Cheung Yookyung Kim Sung Shine Shim Soo Mee Lim 《Korean journal of radiology》2011,12(1):89-96
Objective
The aim of this study was to evaluate the usefulness of combined fluoroscopy- and CT-guided transthoracic needle biopsy (FC-TNB) using a cone beam CT system in comparison to fluoroscopy-guided TNB (F-TNB).Materials and Methods
We retrospectively evaluated 74 FC-TNB cases (group A) and 97 F-TNB cases (group B) to compare their respective diagnostic accuracies according to the size and depth of the lesion, as well as complications, procedure time, and radiation dose.Results
The sensitivity for malignancy and diagnostic accuracy for small (< 30 mm in size) and deep (≥ 50 mm in depth) lesions were higher in group A (91% and 94%, 92% and 94%) than in group B (73% and 81%, 84% and 88%), however not statistically significant (p > 0.05). Concerning lesions ≥ 30 mm in size and < 50 mm in depth, both groups displayed similar results (group A, 91% and 92%, 80% and 87%; group B, 90% and 92%, 86% and 90%). Pneumothorax occurred 26% of the time in group A and 14% for group B. The mean procedure time and patient skin dose were significantly higher in group A (13.6 ± 4.0 minutes, 157.1 ± 76.5 mGy) than in group B (9.0 ± 3.5 minutes, 21.9 ± 15.2 mGy) (p < 0.05).Conclusion
Combined fluoroscopy- and CT-guided TNB allows the biopsy of small (< 30 mm) and deep lesions (≥ 50 mm) with high diagnostic accuracy and short procedure times, whereas F-TNB is still a useful method for large and superficial lesions with a low radiation dose. 相似文献19.
Oral magnesium therapy, exercise heart rate, exercise tolerance, and myocardial function in coronary artery disease patients
下载免费PDF全文
![点击此处可从《British journal of sports medicine》网站下载免费的PDF全文](/ch/ext_images/free.gif)
Pokan R Hofmann P von Duvillard SP Smekal G Wonisch M Lettner K Schmid P Shechter M Silver B Bachl N 《British journal of sports medicine》2006,40(9):773-778
Background
Previous studies have demonstrated that in patients with coronary artery disease (CAD) upward deflection of the heart rate (HR) performance curve can be observed and that this upward deflection and the degree of the deflection are correlated with a diminished stress dependent left ventricular function. Magnesium supplementation improves endothelial function, exercise tolerance, and exercise induced chest pain in patients with CAD.Purpose
We studied the effects of oral magnesium therapy on exercise dependent HR as related to exercise tolerance and resting myocardial function in patients with CAD.Methods
In a double blind controlled trial, 53 male patients with stable CAD were randomised to either oral magnesium 15 mmol twice daily (n = 28, age 61±9 years, height 171±7 cm, body weight 79±10 kg, previous myocardial infarction, n = 7) or placebo (n = 25, age 58±10 years, height 172±6 cm, body weight 79±10 kg, previous myocardial infarction, n = 6) for 6 months. Maximal oxygen uptake (VO2max), the degree and direction of the deflection of the HR performance curve described as factor k<0 (upward deflection), and the left ventricular ejection fraction (LVEF) were the outcomes measured.Results
Magnesium therapy for 6 months significantly increased intracellular magnesium levels (32.7±2.5 v 35.6±2.1 mEq/l, p<0.001) compared to placebo (33.1±3.1.9 v 33.8±2.0 mEq/l, NS), VO2max (28.3±6.2 v 30.6±7.1 ml/kg/min, p<0.001; 29.3±5.4 v 29.6±5.2 ml/kg/min, NS), factor k (−0.298±0.242 v −0.208±0.260, p<0.05; −0.269±0.336 v −0.272±0.335, NS), and LVEF (58±11 v 67±10%, p<0.001; 55±11 v 54±12%, NS).Conclusion
The present study supports the intake of oral magnesium and its favourable effects on exercise tolerance and left ventricular function during rest and exercise in stable CAD patients. 相似文献20.