首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.
目的 探讨病灶清除植骨保留髋臼假体的翻修术治疗全髋关节置换(total hip arthroplasty,THA)术后稳定固定的髋臼假体周围局灶性骨溶解的疗效.方法 2006年3月至2009年3月,THA术后髋臼假体稳定固定的假体周围局灶性骨溶解患者23例(23髋),男13例,女10例;年龄39~54岁,平均46.6岁.23例均为非骨水泥髋臼.初次THA至诊断髋臼假体周围骨溶解的时间为4.6~7.4年,平均5.5年.术前HarTis髋关节评分74分.手术经腹股沟入路,行髂骨内板开窗,清除髋臼骨溶解病灶、同种异体颗粒骨植骨;经后外侧人路更换聚乙烯内衬、股骨头假体,保留髋臼假体.翻修术后1、3、6、12个月及之后每年随访1次,以髋关节Harris评分评价临床疗效,摄X线片、CT扫描观察植骨区愈合、新发骨溶解病灶及假体移位情况.结果 16例获得随访,随访时间8~38个月,平均28个月.末次随访时Harris髋关节评分86~100分,平均93.8分.16例植骨区成骨均良好,12例植骨区完全被周围骨爬行替代,髋臼假体固定好,无髋臼假体松动及移位,无新发髋臼假体周围骨溶解,无异位骨化、脱位、深静脉血栓形成及感染等并发症.结论 清除病灶植骨、保留髋臼假体、更换聚乙烯内衬和股骨头假体的翻修术可有效减少聚乙烯磨损颗粒产生,避免骨溶解病灶进展导致的假体松动,近期随访结果良好.  相似文献   

2.
With an increase of revision total hip arthroplasty (THA), the choice of bearing surface becomes more important. Wear debris by conventional metal-on-polyethylene articulations may cause extensive osteolysis, especially in young patients. We analyzed the clinical and radiographic outcomes after revision THA using third-generation ceramic-on-ceramic bearing surfaces in 42 hips. The mean age of the patients was 48.8 years (32-59 years), and the mean duration of follow-up monitoring was 5.4 years (3.2-8.0 years). At final follow-up examination, the average Harris Hip Score was 91.3. Although minor complications were observed in 6 hips (14.3%), no hips required additional revision surgery. No hip showed radiolucent lines, acetabular cup migration, or osteolysis. Our data show that clinical and radiographic outcomes after revision THA using third-generation ceramic-on-ceramic bearing surfaces are favorable. Ceramic-on-ceramic bearing surfaces can be preferentially considered for revision THA, especially in young patients. Further studies with long-term follow-up data are warranted.  相似文献   

3.
《Injury》2021,52(6):1467-1472
IntroductionTotal hip arthroplasty (THA) after femoral neck fracture (FNF) is associated with an increased risk of dislocation. The goals of our study were (1) to determine dislocation and revision rates when dual-mobility cups (DMCs) are used in these patients, (2) to analyze clinical and radiographic outcomes, survivorship, complications and mortality rate, and (3) to compare results between cemented and cementless cups.Patients and methodsWe retrospectively reviewed patients with FNF treated using DMC-THA between 2011 and 2018. A minimum 2-year follow-up was required for clinical and radiographic assessment. The clinical outcome was assessed using the Harris Hip Score (HHS) and Merlé D´Aubigné-Postel score (MDP). Radiolucent lines, osteolysis and cup loosening were analyzed.ResultsWe included 105 patients (105 hips) with a mean age of 75.5 years. There were no dislocations. One patient (1.0%) underwent cup revision at 39 months for aseptic cup loosening. The mean HHS and MDP were 80.5 and 14.2 respectively at a mean follow-up of 4.1 years. A higher MDP was found in patients with cementless rather than cemented cups (15.0 vs. 13.1; p = 0.006). Four patients had radiolucent lines > 1 mm, around cemented cups. At 6.8 years, estimated cup survival was 98.2% for revision for aseptic loosening and 97.3% for revision for any reason. The mortality rates were 6.7% at 1 year and 23.8% at last follow-up.ConclusionOur findings suggest that using DMC in THA for FNF may prevent dislocation with a low revision rate. Cementless cups had a higher MDP than cemented cups.  相似文献   

4.
BACKGROUND: Removal of a well-fixed cementless acetabular component can result in increased operative time and postoperative morbidity. The objectives of this retrospective study were to determine whether retention of a well-fixed acetabular component at the time of isolated femoral revision was compatible with long-term socket survival. METHODS: The records of eighty-three consecutive patients (ninety hips) in whom a well-fixed cementless socket had been retained during revision of a femoral component were reviewed. The mean age of the patients was 48.7 years at the time of the primary arthroplasty and 54.1 years at the time of femoral revision. The radiographic analysis was based on anteroposterior radiographs and was performed by a single independent reviewer. The intraoperative criterion for stability of the socket was the absence of movement at the bone-implant interface during the application of direct pressure to the edges of the socket in four quadrants with use of a metallic pusher. RESULTS: At the time of the isolated femoral revision, no socket demonstrated a radiolucent line measuring >1 mm in any two zones and forty of the ninety hips had periacetabular osteolysis. The mean size of the osteolytic lesions was 5.71 cm(2) (range, 0.4 to 24.2 cm(2)), and twenty-eight of the forty hips underwent bone-grafting. The mean duration of follow-up was 9.7 years after the isolated femoral revision and 14.9 years after the primary arthroplasty. Five acetabular sockets were revised at a mean of 6.8 years after the femoral revision. Only one of these sockets had failed because of aseptic loosening. With revision of the acetabular component for any reason as the end point, the survival rate was 98.7% at five years and 93.5% at ten years after the femoral revision and 100% at ten years and 93.9% at fifteen years after the primary arthroplasty. No hip showed recurrence or expansion of periacetabular osteolysis. The prevalence of dislocation was 16% (fourteen of ninety). CONCLUSIONS: Revision of a stable, cementless acetabular component solely on the basis of its duration in vivo or the presence of periacetabular osteolysis does not appear to be warranted. Retention of the socket with grafting of larger periacetabular osteolytic lesions appears to be consistent with satisfactory socket longevity.  相似文献   

5.
 目的 探讨金属-高分子聚乙烯负重界面全髋关节置换(total hip arthroplasty, THA)术后髋周炎性假瘤的诊断及治疗。方法 2006 年3月至2011 年6 月, 初次金属-高分子聚乙烯负重界面非骨水泥固定THA 术后发生假体周围局灶性骨溶解, 经X 线片和(或)三维CT扫描、超声检查诊断为炎性假瘤7 例(7 髋)。男2 例, 女5 例;年龄32~65岁, 平均48.8 岁。假体稳定固定, 有聚乙烯不对称磨损及髋臼DeLee和Charnley II区局灶性骨溶解, 其中1 例同时有股骨Gruen II区局灶性骨溶解。行炎性假瘤包块切除、骨溶解病灶清除及同种异体颗粒骨植骨, 更换陶瓷-高交联聚乙烯负重界面治疗。结果 7例患者随访3~42 个月, 平均30 个月。无局部炎性假瘤复发、假体周围新发骨溶解及假体松动。4 例假体周围骨溶解区完全被骨组织替代, 2 例有较好的骨长入, 1 例骨长入不明显, 但假体稳定。末次随访时Harris髋关节评分86~100 分, 平均92.4 分。无假体周围感染、异位骨化、假体周围骨折等并发症, 无假体失败而需翻修者。结论 初次THA术后聚乙烯磨损可诱发骨盆内髋周炎性假瘤及假体周围局灶性骨溶解;在手术切除炎性假瘤、清除骨溶解病灶并植骨, 更换负重界面的情况下可保留稳定固定的假体。  相似文献   

6.
This study was designed to evaluate the midterm (> or = 5 years) clinical and radiographic outcomes of the cementless total hip arthroplasty in 64 Chinese patients (72 hips), which revealed that the mean Harris hip score increased from an average of 44.0 points before operation to 92.4 points at the last follow-up. Excellent results were achieved in 60 hips (83%). No loosening of the components was observed radiographically. No revision of the femoral components was required. Only one focal area of pelvic osteolysis in 1 hip (1%), which requires a revision, and some small focal areas of femoral osteolysis in 12 hips (17%) were observed. The mean linear wear rate was 0.125 mm/y. The survival rate of the acetabular and femoral components for radiographic loosening was 100% (95% confidence interval, 0.93-1.0) and for revision was 98.61% (95% confidence interval, 0.95-1.0). This study indicated that the cementless total hip arthroplasty in patients with osteonecrosis of the femoral head has a satisfactory midterm clinical and radiographic outcomes, but the long-term effect should be further studied.  相似文献   

7.
This study evaluated the 5- to 19-year clinical and radiographic results of cementless acetabular revision. Between 1986 and 1998, 130 hips (125 patients) underwent cementless acetabular revisions. Ten patients were lost to follow-up; 6 patients died. One hundred nine patients (114 hips) were reviewed at a mean follow-up of 8.8 years. The mean Harris hip score improved from 62.1 to 90.7 at final follow-up. Two hips underwent repeat revision. Twenty-two hips developed cavitary osteolysis. Kaplan-Meier survivorship at 121 months was 98.2% with repeat revision for any reason as the end point and 89.5% with repeat revision or radiographic loosening as the end point. Cementless acetabular revision provides favorable clinical and radiographic results, and the initial disease and age may adversely affect the outcomes.  相似文献   

8.
The results of revision of well-fixed Porous Coated Anatomic cementless acetabular components for polyethylene failure or periacetabular osteolysis in 18 hips (14 patients) are reported. Revisions were done with larger diameter cementless acetabular components replacing one-piece Porous Coated Anatomic devices for which no replacement liner was available. The objective was to determine the increase in size of the revision acetabular component and to assess clinical and radiographic outcomes. The Porous Coated Anatomic components were in place for an average of 7.8 years. At an average followup of 68 months, all revision components remain in place. Preoperatively, 12 hips in 10 patients had radiographic osteolysis, and 25 osteolytic lesions in 17 patients were grafted at revision. All grafted lesions showed partial or complete evidence of bone graft consolidation. The average revision component size increased 8.5 mm in diameter (range, 3-14 mm) compared with the primary component size. This corresponded to an average 6.5-mm increase in the acetabular cavitary diameter. When locking mechanism failure in a well-fixed cementless acetabular component prevents polyethylene liner replacement, acetabular component revision can provide good clinical and radiographic results with acceptable bone loss and improved access to osteolytic areas for debridement and grafting.  相似文献   

9.
BackgroundPatients undergoing primary total hip arthroplasty (THA) following pelvic radiation have historically had poor survivorship free of aseptic acetabular component loosening. However, several series have reported improved results with tantalum acetabular components. The purpose of this study is to assess implant survivorship, radiographic results, and clinical outcomes of contemporary, porous titanium acetabular components in the setting of prior pelvic radiation.MethodsWe retrospectively reviewed 33 patients (38 hips) with prior pelvic radiation between 2006 and 2016 who underwent primary THA. The mean overall pelvic radiation dose was 6300 cGy with a mean latency period to THA of 5 years. The most common acetabular component was Pinnacle (DePuy Synthes) in 76%. Eight-seven percent of cups were fixed with screws. The mean age at primary THA was 74 years, 76% were male, and the mean body mass index was 30 kg/m2. Mean follow-up was 5 years.ResultsThe 10-year survivorship free of revision for aseptic loosening, free of any revision, and free of any reoperation were 100%, 89%, and 89%, respectively, when accounting for death as a competing risk. There were 3 revisions; one each for taper corrosion, recurrent dislocation, and infection. Radiographically, all cups had evidence of osteointegration and none had radiographic evidence of loosening. The mean Harris Hip Score improved from 50 to 84 postoperatively (P < .0001).ConclusionContemporary porous titanium acetabular components with supplemental screws provided excellent implant fixation in patients with prior therapeutic pelvic radiation. At 10 years, 100% of these components were free of revision for aseptic loosening and 100% were radiographically well-fixed.Level of EvidenceLevel IV, Therapeutic.  相似文献   

10.
Despite improvements in the quality of alumina ceramics, osteolysis has been reported anecdotally after total hip arthroplasty (THA) with use of a contemporary alumina-on-alumina ceramic bearing. The purpose of this study was to evaluate the clinical and radiographic outcomes of THA using alumina-on-alumina ceramic bearing and to determine osteolysis using radiographs and computed tomographic (CT) scans in young patients. Consecutive primary cementless THA using alumina-on-alumina ceramic bearing were performed in 64 patients (93 hips) who were younger than 45 years of age with femoral-head osteonecrosis. There were 55 men (84 hips) and nine women (nine hips). Average age was 38.2 (range 24–45) years. Average follow-up was 11.1 (range 10–13) years. Preoperative Harris Hip Score was 52.9 (range 22–58) points, which improved to 96 (range 85−100) points at the final follow-up examination. Two of 93 hips (2%) had clicking or squeaking sound. No hip had revision or aseptic loosening. Radiographs and CT scans demonstrated that no acetabular or femoral osteolysis was detected in any hip at the latest follow-up. Contemporary cementless acetabular and femoral components with alumina-on-alumina ceramic bearing couples function well with no osteolysis at a ten year minimum and average of 11.1-year follow-up in this series of young patients with femoral-head osteonecrosis.  相似文献   

11.
BACKGROUND: Loosening of the acetabular component is the major long-term problem associated with total hip arthroplasty with cement. The purpose of the present study was to evaluate the minimum thirteen-year results associated with cementless acetabular components that had been inserted by a single surgeon and to compare them with the results associated with cemented acetabular components that had been inserted by the same surgeon. METHODS: One hundred and twenty consecutive, nonselected primary total hip replacements were performed in 108 patients with use of a Harris-Galante-I cementless acetabular component and a cemented femoral component with a 28-mm head. The patients were evaluated clinically with use of a standard terminology questionnaire, and they were evaluated radiographically for loosening, component migration, wear, and osteolysis. The rates of revision for aseptic loosening and radiographic evidence of loosening for this cohort were compared with the rates for four previously reviewed consecutive series of hips in which the acetabular component had been inserted with cement. All patients were managed by the same surgeon, were followed for thirteen to fifteen years, and were evaluated with use of the same two criteria (revision and loosening) as the end points for Kaplan-Meier analysis. RESULTS: Sixty-six patients (seventy-two hips) were living and forty-two patients (forty-eight hips) had died after thirteen to fifteen years of follow-up. No acetabular component had been revised because of aseptic loosening, and no acetabular component had migrated. With revision of the acetabular component for any reason as the end point, the survival rate was 81% +/- 8% at fifteen years. With revision of the acetabular component for clinical failure (osteolysis, wear, loosening, or dislocation) as the end point, the survival rate was 94% +/- 8% at fifteen years. Among the seventy hips with at least thirteen years of radiographic follow-up, five had pelvic osteolysis and three had had revision of a well-fixed acetabular component because of pelvic osteolysis secondary to polyethylene wear. The mean linear wear rate was 0.15 mm/yr (0.12 mm/yr when one outlier was excluded). CONCLUSIONS: In terms of fixation, Harris-Galante-I cementless acetabular components performed better than did cemented 22-mm-inner-diameter Charnley acetabular components as well as 28-mm-inner-diameter all-polyethylene and metal-backed acetabular components that had been inserted by the same surgeon. However, the rate of wear was greater in association with the Harris-Galante-I cementless components than it was in association with the Charnley cemented all-polyethylene components.  相似文献   

12.
《The Journal of arthroplasty》2023,38(7):1335-1341
BackgroundCementing a new liner into a secure, well-positioned metallic shell can be a less-invasive strategy in revision total hip arthroplasty (THA). This study aimed to report the mean 14-year outcomes of cementing highly cross-linked polyethylene (XLPE) liners into well-fixed acetabular shells in revision THAs.MethodsThis study reviewed a single-surgeon series of cementing XLPE liners into well-fixed acetabular components. Of the 52 hips (51 patients) evaluated, 48 hips (47 patients) that satisfied a minimum follow-up of 10 years were included. The Harris Hip score was used for clinical evaluation. Final hip radiographs were used to determine the extent of acetabular osteolysis and stability of the components. The mean age at index operation was 53 years (range, 32 to 72). The mean follow-up duration was 14 years (range, 10 to 18).ResultsThe mean Harris Hip score improved from 58 points (range, 23-81) preoperatively to 91 points (range, 45-100) at the final evaluation (P < .001). A total of 3 acetabular rerevisions were performed, all for aseptic loosening of the outer shell. One postoperative dislocation occurred, but it was successfully treated with a closed reduction. Final radiographs showed a significant reduction in acetabular osteolysis (P < .001). Implant survivorship free from any rerevision was 93.3% (95% confidence interval, 85.9-100%) at 14 years.ConclusionCementing an XLPE liner into a well-fixed acetabular shell in revision THA demonstrated excellent clinical and radiographic outcomes at a mean of 14 years postoperatively. This technique could be a safe and durable option in the absence of XLPE liners compatible with preimplanted shells.  相似文献   

13.
BACKGROUND: Constrained acetabular components have been used to treat hips with recurrent instability following total hip arthroplasty and hips that demonstrate instability during revision surgery. In such hips, when a secure cementless acetabular shell is present, the surgeon can cement a constrained liner into the existing shell. The purpose of this study was to evaluate the clinical and radiographic outcome of this technique with use of a tripolar constrained liner that was cemented into a well-fixed cementless acetabular shell. METHODS: Between 1988 and 2000, constrained liners were cemented into thirty-one well-fixed cementless acetabular shells at three centers. The average age of the patients at the time of the index surgery was 72.1 years, and the indications for the procedure were recurrent hip instability in sixteen hips and intraoperative instability in fifteen hips. The patients were evaluated with respect to the clinical outcome and radiographic evidence of shell loosening and osteolysis. RESULTS: At an average duration of follow-up of 3.9 years, twenty-nine liners (94%) were securely fixed in the cementless shells and two constrained liners had failed. One liner failed because it separated from the cement, and one failed because of fracture of the capturing mechanism. Both hips were successfully revised with another cemented tripolar constrained liner. No acetabular component demonstrated radiographic evidence of progressive loosening or osteolysis. CONCLUSIONS: A constrained tripolar liner cemented into a secure, well-positioned cementless acetabular shell provides stability and durability at short-term follow-up. Careful attention to the preparation of the liner, the sizing of the component, and the cementing technique are likely to reduce the failure of this construct, which can be used for difficult cases of total hip instability.  相似文献   

14.
The first 100 consecutive primary hip arthroplasties with the Arthopor 2 acetabular component (Joint Medical Products, Stamford, CT) with supplemental screw fixation performed by the senior author were prospectively studied. The mean patient age was 57 years. Seventy-seven cemented and 23 cementless stems were placed, with 32-mm femoral heads used in most of the patients. Eighty-six hips were reviewed at 7–8.8 years (mean, 7.8 years). The mean Harris hip score at final follow-up evaluation was 94 points. No cups have been revised, although 2 cups in patients with radiation osteonecrosis were loose radiographically. One patient underwent revision of a severely worn liner. Despite a relatively high mean linear wear rate of 0.27 mm/y (range, 0.13–0.57 mm/y), no radiographic evidence of pelvic osteolysis was seen. The Arthopor 2 cup performed well with respect to pelvic osteolysis, despite the presence of substantial polyethylene debris. The relatively high polyethylene wear rate is attributed in part to the younger patient population and the use of 32-mm femoral heads paired with thin polyethylene liners.  相似文献   

15.
We reviewed 24 hips that developed femoral osteolytic lesions following cementless total hip replacement with a Porous-Coated Anatomic prosthesis after a mean of 8 (6-10) years. 15 of the hips showed hardly any radiographic deterioration in the osteolysis. 2 became much worse with dramatic loss of bone stock. Both of these hips required revision of the acetabular component as well as bone grafting of the otherwise well-fixed femoral component. The remaining 7 hips showed mild-to-moder ate enlargement of the lesions. All 24 hips were asymptomatic.  相似文献   

16.
Seventy-two cementless total hip arthroplasties were performed by a single surgeon in 58 patients with the diagnosis of femoral head osteonecrosis. All patients were less than 50 years old (mean, 37 years). The mean follow-up was 84 months with a minimum of 48 months. Good-to-excellent results were maintained at final follow-up in 94% of the hips. Revision rate was 1.5% each for the cups and the stems. Mechanical failure rate was 7.6% for the cups, and 6% for the stems. If the results were analyzed excluding the data from the group of patients who received the Mittelmeier prostheses, the mechanical failure rates for the cups was 0% and for the stems was 4.2%. The probability of survival for the entire series using revision as the endpoint was 96.9% at 11 years. Survival probability decreased to 88.5% if radiographic failures were included. Excluding the Mittelmeier prostheses, survival probability was estimated to be 100% for the cups using both revision and radiographic failures as endpoints; for the stems, the survival probability was 98.0% using revision as the endpoint and 95.8% including radiographic failures. Femoral osteolysis was observed in 1.5% of the hips. No hip had acetabular osteolysis. No measurements of polyethylene wear were attempted in this study. These results appeared superior to total hip arthroplasties done with early cementing techniques in this population of young patients with femoral head osteonecrosis.  相似文献   

17.
We present a radiographic follow-up of an uncemented, nonmodular, pure titanium-backed acetabular component at 6 to 12 years postimplantation. Between 1990 and 1992, 130 primary total hip arthroplasties were carried out by 1 surgeon using this implant, in association with both cemented and uncemented femoral components. There were 19 deaths, 5 revisions, and 19 hips lost to follow-up, leaving 87 hips available for review at a mean of 9.6 years. Two revisions were for infection, whereas 3 well-fixed cups were changed at the time of revision of a loose femoral component to allow downsizing to a 28-mm head. No cup has been revised for aseptic loosening. There was no radiographic evidence of periacetabular osteolysis or loosening of any of the cups, even in a subgroup of 31 patients who were 60 years or younger at the time of implantation.  相似文献   

18.

Background

Second-generation, metal-on-metal total hip arthroplasty (MoM THA) using a 28-mm head has shown favorable results compared with large head MoM THA. The purpose of this study is to evaluate the long-term outcomes of cementless primary MoM THA with a 28-mm head and the incidence of osteolysis using computed tomography.

Methods

A total of 92 patients (53 men and 39 women) who underwent primary cementless MoM THA (114 hips) with a 28-mm head were enrolled in this study. Their mean age was 46.2 years at the time of surgery. The mean follow-up duration was 20 years. The Harris hip score, presence of thigh or groin pain, radiographic results, presence of peri-implant osteolysis, histologic analysis, and Kaplan-Meier survival curves were evaluated.

Results

The mean preoperative Harris hip score of 50.5 improved to 85.1 at the final follow-up. Eight patients (8 hips) experienced groin pain, but none had thigh pain. Twelve revisions (6.2%) were performed including 10 hips for aseptic loosening with osteolysis and 2 hips for periprosthetic fracture around the stem. At 23 years, 91% of patients were free from revision of the acetabular component due to aseptic loosening and 90.1% were free from revision of both femoral and acetabular components due to any reason. Osteolysis was identified around the cup in 12 cases (10.5%) and around the stem in 7 cases (6.1%).

Conclusion

MoM THA with a 28-mm head showed a relatively low rate of aseptic implant loosening at a mean follow-up of 20 years.  相似文献   

19.
This study was to determine the mid- to long-term survivorship of cementless metal-on-metal THA in 52 patients (74 hips) who underwent THA for osteonecrosis of the femoral head with a cementless THA. The mean follow-up was 10.2 years. The mean age at operation was 42.1 years (range, 25–62 years). The survivorship analysis with revision as the end point estimated a 96.6% chance of THA survival during 16.4 years. The average Harris hip score at last follow-up was 89.2 points (range, 74–100). Two patients (two hips) required revision surgery for extensive acetabular osteolysis at 9 years and acetabular liner dissociation at 2 years. The survival rates of cementless THA in these patients are encouraging. However, the possibility of metallic wear related complications are raising concern.  相似文献   

20.
人工全髋关节翻修术中骨缺损的处理   总被引:1,自引:0,他引:1  
目的研究全髋关节翻修术中骨缺损的处理方法。方法1990年12月至1999年6月对16例一期行金属-聚乙烯假体全髋关节置换术失败患者行全髋关节翻修术。处理髋臼骨缺损的方式包括:(1)髂骨填充骨缺损(3例),(2)骨水泥填充骨缺损(5例),(3)异体颗粒骨打压植骨结合金属网重建髋臼(8例),后两种方式均属骨水泥型。16例行全髋关节翻修术患者全部行髋臼翻修,其中10例同时行股骨柄翻修。所有患者均进行临床和影像学随访。结果所有患者均获得随访,随访时间4.1~7.7年,平均5.9年。Harris评分由全髋关节翻修术前的范围,62-75分,平均68分,升至术后的90—94分,平均91分。随访中均未出现假体旁透亮线、假臼杯水平或垂直移位和骨溶解等征象。共有4例出现并发症,包括异位骨化2例,脱位2例,无一例发生感染。结论有效修复髋臼骨缺损,进行髋部骨性结构的重建,是全髋关节翻修术成败的关键。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号