首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
目的探讨新型单椎单侧椎弓根导向模板辅助下颈椎椎弓根个体化置钉的准确性。方法对需要行颈椎后路椎弓根内固定治疗的22例下颈椎患者术前行CT扫描,根据CT扫描资料,利用逆向工程原理及快速成型技术,采用Mimics 16.0和Imageware 12.0软件,制作颈椎三维模型,并设计出个体化的新型单椎单侧椎弓根导向模板,辅助颈椎椎弓根置钉。术后复查颈椎CT评价椎弓根螺钉的位置,按照Lee et al的评定方法将螺钉在椎弓根内的位置分为4级:0级,螺钉完全位于椎弓根内;1级,穿破椎弓根的部分螺钉直径的25%;2级,螺钉直径的25%~50%穿破椎弓根;3级,穿破椎弓根的部分螺钉直径的50%。0级和1级认为置钉满意,2级和3级认为螺钉误置。结果 22例均获得随访,时间6~36个月。22例患者共置入椎弓根螺钉113枚,改为侧块螺钉固定3枚。术后复查CT提示椎弓根螺钉位置107枚为0级,4枚为1级,2枚为2级。仅2例发生误置,置钉准确率达98.2%。其中1级和2级共6枚椎弓根螺钉均穿破椎弓根外侧壁,无椎弓根内侧壁及上、下壁穿破情况。对螺钉穿破外侧壁的患者行椎动脉MRA检查,未见椎动脉损伤。患者均未出现螺钉误置导致的脊髓、神经损伤并发症。结论新型单椎单侧椎弓根导向模板辅助下颈椎椎弓根个体化置钉准确性高,相关并发症少,为下颈椎椎弓根的置入提供了一种新的方法。  相似文献   

2.
目的探讨微创经皮椎弓根螺钉内固定置钉的准确性及安全性。方法分析微创经皮椎弓根螺钉内固定治疗64例胸腰椎骨折患者的临床及影像学资料,评价椎弓根螺钉的位置。按照Lee等的评价方法将螺钉位置分为4级,0级:螺钉完全在椎弓根内;1级:穿破椎弓根部分小于螺钉直径的25%;2级:穿破椎弓根部分达到螺钉直径的25%~50%;3级:穿破椎弓根部分大于螺钉直径的50%。0级和1级认为置钉满意,2级和3级认为螺钉误置,观察血管神经损伤等并发症情况。结果 64例患者共置入椎弓根螺钉256枚,术后复查CT显示椎弓根螺钉位置0级223枚,椎弓根螺钉位置1级25枚,椎弓根螺钉位置2级7枚,椎弓根螺钉位置3级1枚。椎弓根螺钉的误置率为3.1%。其中误置的8枚椎弓根螺钉中5枚穿破椎弓根内侧壁,3枚穿破外侧壁,无椎弓根上、下壁穿破情况。有1例患者术后出现下肢根性疼痛症状,予对症治疗后症状消失,无血管损伤等并发症发生。结论微创经皮椎弓根螺钉内固定治疗腰椎骨折患者置钉准确性高,相关并发症少,在胸腰椎骨折治疗中值得广泛应用。  相似文献   

3.
下颈椎椎板和侧块作为椎弓根置钉角度参考标志的可靠性   总被引:1,自引:0,他引:1  
【摘要】 目的:探讨下颈椎椎板和侧块作为椎弓根置钉角度参考标志的可靠性。方法:完整成人颈椎骨性标本10具,男、女各5具,模拟施行下颈椎椎弓根置钉手术;术前对C3~C7进行螺旋CT扫描多平面重建,确定椎弓根进钉轴,并以椎板和侧块作为椎弓根内倾角和上倾角的参考标志,测量椎弓根进钉轴与同侧椎板的夹角(PL角)及与侧块后表面的夹角(PLM角),术中以相同参考标志和置钉角度置入椎弓根螺钉。术后复查CT并评估椎弓根螺钉置钉的准确率:0级,螺钉完全位于椎弓根内;1级,穿破椎弓根的部分<螺钉直径的25%;2级,螺钉直径的25%~50%穿破椎弓根;3级,螺钉直径>50%穿破椎弓根;2级和3级螺钉为误置。对颈椎标本各节段椎弓根螺钉位置的分级与椎弓根的宽度与高度进行相关性分析。2011年10月~2012年12月,用同样方法对6例患者进行下颈椎椎弓根螺钉置钉手术,评估置钉准确率和并发症情况。结果:10具颈椎标本的下颈椎椎弓根的PL角,C3、C4>C5、C6>C7;PLM角,C3、C4相似文献   

4.
【摘要】 目的:探讨改良3D打印导板辅助颈椎椎弓根螺钉置钉的准确性。方法:回顾性分析2016年1月~2023年1月在我院行颈椎后路椎弓根螺钉内固定手术的60例患者的临床资料,其中男30例,女30例,年龄58.7±13.8岁(17~84岁);根据颈椎后路手术是否使用导板辅助置钉分为导板组及徒手置钉组。导板组(30例)采用改良3D打印导板辅助颈椎椎弓根置钉,徒手置钉组(30例)采用角度尺辅助颈椎弓根置钉,两组患者年龄、性别、术前诊断无统计学差异(P>0.05)。所有患者术后1周行颈椎CT扫描,按照Kaneyama标准判断椎弓根置钉准确性:0级,螺钉完全处于椎弓根中,没有穿破骨皮质;1级,螺钉穿破皮质<螺钉直径的50%;2级,螺钉穿破皮质≥螺钉直径的50%但没完全穿出;3级,完全穿出骨皮质。记录椎弓根置钉准确率(0级+1级螺钉占比)及因螺钉误置导致的血管神经损伤、切口感染、脑脊液漏、螺钉松动断裂等并发症。结果:导板组共置入椎弓根螺钉152枚,其中0级74枚,1级68枚,2级10枚,3级0枚,置钉准确率93.4%;徒手置钉组共置入椎弓根螺钉136枚,其中0级53枚,1级61枚,2级18枚,3级4枚,置钉准确率83.8%,导板组置钉准确率高于徒手置钉组(P<0.05)。所有患者均未出现因椎弓根螺钉误置导致的血管神经损伤、切口感染及脑脊液漏等相关并发症。所有患者随访5~29个月(14.2±7.7个月),无内固定松动、断裂等并发症。结论:改良3D打印导板辅助颈椎椎弓根置钉可提高置钉精准度。  相似文献   

5.
目的 :通过3D打印技术及骨科数字化技术制作下颈椎前路椎弓根螺钉置钉导航模板,观察模板辅助下置钉的准确性。方法:选取正常成人颈椎湿性标本10具(男、女各5具),将椎前软组织剔除,采用64排薄层CT扫描后获取其DICOM格式数据,导入Mimics软件后三维建模并为颈前路椎弓根螺钉选取理想钉道,设计建立螺钉导航模板后导出其STL数据,通过3D打印机快速打印成型。在导航导板引导下进行下颈椎前路椎弓根螺钉置钉,通过X线及CT评价螺钉的准确性。结果:10具尸体分别于C3~T1每节段置入2枚螺钉,共计120枚,根据螺钉的位置将其分为4级:0级,螺钉完全在椎弓根内,共115枚;1级,螺钉穿破椎弓根皮质,穿出部分小于螺钉直径的25%,1枚;2级,螺钉穿破椎弓根皮质,穿出部分为螺钉直径的25%~50%,3枚;3级,螺钉穿出椎弓根部分大于螺钉直径的50%,1枚。5枚穿破椎弓根皮质者2枚穿破椎弓根内侧皮质,3枚穿破外侧皮质,总体准确性为95.8%。结论:在湿性尸体颈椎标本上应用3D打印及骨科数字化技术制作的导航模板辅助行下颈椎前路椎弓根螺钉置钉的准确性高,为临床应用提供了依据。  相似文献   

6.
目的 :比较O型臂3D导航下C1、C2椎弓根螺钉置钉与徒手置钉精确性的差异,探讨O型臂导航在上颈椎椎弓根螺钉置钉中的应用价值。方法:纳入我院C1、C2椎弓根螺钉内固定患者62例,分为导航置钉组(A组)与徒手置钉组(B组)。A组:2014年1月~2015年3月,O型臂导航下行C1、C2后路椎弓根螺钉内固定术22例,男15例,女7例,年龄17~58岁(40.8±12.7岁);B组:2005年3月~2013年12月经徒手置入C1及C2椎弓根螺钉患者40例,男26例,女14例,年龄12~70岁(42.0±15.6岁)。所有患者术后均行颈椎CT平扫,按照Neo等的方法,根据椎弓根螺钉穿破椎弓根皮质的程度将置钉精确性分为四级(0级,螺钉完全处于椎弓根中,没有穿破骨皮质;1级,螺钉穿破皮质2mm,或小于螺钉直径的50%;2级,螺钉穿破皮质≥2mm且﹤4mm,或大于螺钉直径的50%但没完全穿出;3级,完全穿出皮质,螺钉处于椎管或椎动脉孔内),分别评估两组的置钉精确性并比较两组间的差异。结果:A组共置入C1、C2椎弓根螺钉67枚(C1 28枚,C2 39枚),其中0级60枚(89.6%),1级7枚(10.4%),无2级或3级不良置钉;B组共置入C1、C2椎弓根螺钉134枚(C1 64枚,C2 70枚),其中0级116枚(86.6%),1级13枚(9.7%),2级4枚(3.0%),3级1枚(0.7%)。两组间置钉精确性分级(P=0.49)及0级置钉率(P=0.55)均无统计学差异;A组未发现不良置钉,B组不良置钉发生率为3.7%,但组间无统计学差异(P=0.17)。两组均无置钉相关的血管、神经并发症发生。结论:术中O型臂导航与徒手置钉在上颈椎椎弓根螺钉置钉精确性上并无统计学差异,虽然导航能提供清晰的术中3D图像,但该技术未能完全避免置钉时螺钉轻度穿破骨皮质的发生,仍需提高术者与导航系统间的交互作用,完善操作技术,进一步提高置钉精确性。  相似文献   

7.
个体化导航模板在胸椎椎弓根螺钉置入中的初步临床应用   总被引:1,自引:0,他引:1  
目的:通过临床应用评价个体化导航模板辅助胸椎椎弓根螺钉置入的准确性和安全性。方法:2008年7月~2009年9月,对11例需要行胸椎椎弓根螺钉置入手术的患者(青少年特发性脊柱侧凸7例,先天性脊柱侧凸2例,胸椎结核后凸畸形1例,多发性胸椎骨折1例)术前根据CT三维重建图像利用计算机辅助设计及快速成型技术设计制作46个胸椎个体化导航模板,术中应用个体化导航模板辅助在T2~T12置入椎弓根螺钉92枚,术后CT扫描评价螺钉位置,记录有无与螺钉置入相关的并发症。结果:通过个体化导航模板辅助置入的92枚胸椎椎弓根螺钉中,83枚完全在椎弓根内,9枚穿破椎弓根壁(其中椎弓根内侧壁穿破2枚、椎弓根外侧壁穿破7枚),其中5枚螺钉因椎弓根宽度小于4mm(3.0~3.8mm)而采用椎弓根旁固定方法(椎弓根螺钉轻度穿破椎弓根外侧壁经胸肋关节内侧进入椎体),椎弓根壁非故意穿破率为4.3%,置钉准确率为95.7%,所有穿破椎弓根壁的螺钉的穿出距离均小于2mm,螺钉位置可接受率为100%。无与螺钉置入有关的神经、血管、内脏损伤等并发症的发生。结论:个体化导航模板辅助胸椎椎弓根螺钉置入的置钉准确率高,安全、可行。  相似文献   

8.
[目的]探讨钉道设计在颈椎椎弓根固定中的应用.[方法]2006~2009年16例患者在本院接受下颈椎椎弓根螺钉内固定术,术前采用颈椎螺旋CT三维重建,测量该组患者颈椎椎弓根的长度、宽度、高度、向内侧倾斜、向头侧倾斜、向尾侧倾斜角度的数据,以此为指导行术中置入椎弓根螺钉.术后半月内采用与术前程序一致的螺旋CT三维重建及钉道扫描,观察椎弓根螺钉与椎弓根各壁的关系.[结果]颈椎弓根变异较大.本组共置钉66枚,57枚螺钉完全位于椎弓根内,9枚螺钉穿破椎弓根外侧皮质壁,其中5枚穿破距离为1 mm,4枚螺钉穿破距离为2~3 mm,无椎动脉和脊髓损伤发生,置钉准确率为93%.[结论]钉道设计对术中个体化置入颈椎弓根螺钉有重要意义.  相似文献   

9.
胸腰椎椎弓根螺钉误置的原因分析及对策   总被引:7,自引:1,他引:6  
目的 探讨胸腰椎椎弓根螺钉误置的原因及对策。方法 1996-2002年对293例脊柱疾病患者施行椎弓根螺钉内固定术发生的螺钉误置情况进行回顾性总结,分析。结果 293例共置入椎弓根螺钉1256枚,螺钉植入节段错误7例,占2.38%;上胸椎(T2-7)置钉113枚,有11枚螺钉穿破椎弓根皮质,占9.74%;下胸椎(T8-12)置钉261枚,有9枚螺钉穿破椎弓根皮质,占3.45%;腰骶椎置钉882枚,有16枚穿破椎弓根皮质,占1.81%,共计36枚螺钉,占2.87%;螺钉角异常65枚,占5.81%。结论 椎弓根螺钉误置与操作技术,解剖学变异及脊柱病损因素密切相关;良好的手术技巧,术前影像资料的认真观测及术中必要的影像监控是准确置钉的关键。  相似文献   

10.
[目的]通过尸体标本实验的方法探讨个体化导航模板辅助胸椎椎弓根螺钉置入的准确性及可行性.[方法]对6具胸椎尸体标本进行CT扫描,根据CT扫描资料,利用逆向工程原理及快速成型技术设计制造出个体化导航模板,利用个体化导航模板在尸体标本上辅助置入胸椎椎弓根螺钉,所有螺钉的置入由同一位具有腰椎椎弓根螺钉置钉经验但无胸椎椎弓根螺钉置钉经验的骨科医师进行操作,随后采用大体解剖的方法肉眼观察置钉的准确性;并根据螺钉是否穿破椎弓根、穿出距离及穿破方向进行分级.[结果]共设计制作了72个个体化导航模板辅助置入胸椎椎弓根螺钉144枚,132枚(91.7%)螺钉完全在椎弓根内;12(8.3%)枚螺钉穿破椎弓根,其中2枚螺钉穿破椎弓根内侧壁(穿破距离分别为0.6、0.8 mm),10枚螺钉穿破椎弓根外侧壁(9枚螺钉穿出距离<2 mm,1枚螺钉穿出距离为2.5 mm);没有椎弓根上方、下方及椎体前方穿破的螺钉.所有穿破椎弓根壁的螺钉均在安全可接受的范围内.[结论]快速成型个体化导航模板辅助胸椎椎弓根螺钉置入准确率高,对术者无特别的经验要求,手术操作简单、安全,可避免术中放射性损伤,为胸椎椎弓根螺钉的置入提供了一种新的可行方法,尤其适用于初学者.  相似文献   

11.
Background : We investigated the vasopressor hormone response following mesenteric traction (MT) with hypotension due to prostacyclin (PGI2) release in patients undergoing abdominal surgery with a combined general and epidural anesthesia. Methods : In a prospective, randomized, placebo-controlled study we administered 400 mg ibuprofen (i.v.) in 42 patients scheduled for abdominal surgery. General anesthesia was combined with epidural anesthesia (T4-L1). Before as well as 5, 15, 30, 45, and 90 min after MT we recorded plasma osmolality, hemodynamics and measured 6-keto-PGFlα (stabile metabolite of PGI2), TXB2 (stabile metabolite of thromboxane A2) active renin, and arginine vasopressin (AVP) plasma concentrations by radioimmunoassay. Catecholamine levels were assessed by high-pressure liquid chromatography (HPLC) with electrochemical detection. Results : Following MT, arterial hypotension occurred along with a substantial PGI2 release. This was completely abolished by ibuprofen administration. Although plasma levels of 6-keto-PGF (1133 (708) vs. 60 (3) ng/L, median (median absolute deviation), P=0.0001, placebo vs. ibuprofen) remained significantly elevated, blood pressure was restored within 30 min after MT in the placebo group. At the same point in time plasma concentrations of TXB2 (164 (87) vs. 58 (1) ng/L, P=0.0001), epinephrine (46 (33) vs. 14 (6) ng/L, P=0.001), AVP (41 ± (18) vs. 12 (7) ng/L, P=0.0004), and active renin (27 (12) vs. 12 (4) ng/L, P = 0.001) were significantly higher in placebo-treated patients. Conclusion : Under combined general and epidural anesthesia arterial hypotension following MT due to endogenous PGI2 release is associated with enhanced release of AVP, active renin, epinephrine and thromboxane A2, presumably contributing to hemodynamic stability within 30 min after MT.  相似文献   

12.
Don Dame 《Artificial organs》1996,20(5):613-617
Abstract: Virtually all blood pumps contain some kind of rubbing, sliding, closely moving machinery surfaces that are exposed to the blood being pumped. These valves, internal bearings, magnetic bearing position sensors, and shaft seals cause most of the problems with blood pumps. The original teaspoon pump design prevented the rubbing, sliding machinery surfaces from contacting the blood. However, the hydraulic efficiency was low because the blood was able to "slip around" the rotating impeller so that the blood itself never rotated fast enough to develop adequate pressure. An improved teaspoon blood pump has been designed and tested and has shown acceptable hydraulic performance and low hemolysis potential. The new pump uses a nonrotating "swinging" hose as the pump impeller. The fluid enters the pump through the center of the swinging hose; therefore, there can be no fluid slip between the revolving blood and the revolving impeller. The new pump uses an impeller that is comparable to a flexible garden hose. If the free end of the hose were swung around in a circle like half of a jump rope, the fluid inside the hose would rotate and develop pressure even though the hose impeller itself did not "rotate"; therefore, no rotating shaft seal or internal bearings are required.  相似文献   

13.
Abstract: A variety of protein-bound or hydrophobic substances, accumulating as a result of pathologic conditions such as exogenous or endogenous intoxications, are removed poorly by conventional detoxification methods because of low accessibility (hemodialysis), insufficient adsorption capabilities (hemosorption), low efficiency (peritoneal dialysis), or economic limitations (high-volume plasmapheresis). Combining advantages of existing methods with microspheric technology, a module-based system was designed. Major operating parameters of the latter can be modified to allow for adjustment to individual clinical situations. An extracorporeal blood circuit including a plasmafilter is combined with a secondary high-velocity plasma circuit driven by a centrifugal pump. Different microspheric adsorbers can be combined in one circuit or applied in sequence. Thus, a prolonged treatment can be tailored using specially designed selective adsorber materials. Comparing this system with existing methods (high-flux hemodialysis, molecular adsorbent recycling system), results from our in vitro studies and animal experiments demonstrate the superior efficiency of substance removal.  相似文献   

14.
Background : Our objective was to determine whether administration of propranolol or verapamil modifies the hemodynamic adaptation to continuous positive-pressure ventilation (CPPV), in particular the regional distribution of cardiac output (CO).
Methods : General hemodynamics and regional blood flows assessed by microsphere technique (15 (μm) were recorded in 16 anesthetized pigs during spontaneous breathing (SB) and CPPV with 8 cm H2O end-expiratory pressure (CPPV8) before and after intravenous administration of propranolol (0.3 mg · kg−1 followed by 0.15 mg · kg−1 · h−1, n=8) or verapamil (0.1 mg · kg−1 followed by 0.3 mg · kg−1 · h−1, n=8).
Results : CPPV8 depressed CO by 25% without shifts in its relative distribution with the exception of a noteworthy increase in adrenal perfusion. Propranolol increased arterial blood pressure, and due to a fall in heart rate, CO dropped by 25%. The kidneys and, to a lesser extent, the splanchic region and central nervous system received increased fractions of the remaining CO at the expense of skeletal muscle flow. Similar patterns were seen during SB and CPPV8 such that the combination of propranolol and CPPV8 depressed CO by 50%. The circulatory effects of verapamil were less evident but myocardial perfusion tended to increase.
Conclusions : The combination of propranolol or verapamil with CPPV does not result in any specific hemodynamic interaction in anesthetized pigs, except that the combined effect of propranolol and CPPV may severely reduce CO.  相似文献   

15.
Background: Obesity is increasing globallly, including in the formerly "Eastern Bloc" countries. Methods: A survey was made of obesity and bariatric surgery. Results: In the 8 East and Central European countries studied, with total population 300 million, roughly 43% of the population was overweight (BMI 25-30), 23% obese (BMI > 30), with about 15 million people morbidly obese (BMI > 40). From 0-10 morbidly obese individuals/100,000/year undergo bariatric surgery. Conclusion: Most countries were found to provide inadequate treatment for obesity.The majority of the morbidly obese are not treated effectively. However, health-care awareness of obesity and bariatric surgeons are slowly increasing.  相似文献   

16.
Background : Inhibitory effects of volatile anaesthetics on platelet aggregation have been demonstrated in several studies. However, the influence of volatile anaesthetics on intracoronary platelet adhesion has not been elucidated so far.
Methods : Isolated hearts of guinea pigs were perfused with buffer in the absence or presence of volatile anaesthetics (0.5 and 1 MAC) at constant coronary flow rates of 5 ml/min for 25 min, then 1 ml/min for 30 min and again 5 ml/min for 10 min. Before, during and after low-flow perfusion, a bolus of human platelets was applied into the coronary system. To simulate thrombogenic conditions, 0.3 U/ml human thrombin was infused during low-flow perfusion and reperfusion. The number of platelets sequestered to the endothelium was calculated from the difference between coronary in- and output of platelets. The myocardial production of lactate and consumption of pyruvate and coronary perfusion pressure were also determined.
Results : At a flow rate of 5 ml/min only about 3% of the applied platelets did not emerge from the coronary system, in any group. In contrast, 13.1±1.2% (mean±SEM) of infused platelets became adherent in low-flow perfusion in the control group without anaesthetic. The adherence was reduced with each 1 MAC isoflurane (to 6.2±1.2%), sevoflurane (to 4.4±0.9%) or halothane (to 3.2±1.5%) (each P <0.05 vs. control). Volatile anaesthetic, 0.5 MAC, did not inhibit platelet adhesion to a statistically significant extent in any case. Perfusion pressure and metabolic parameters were not statistically different between the control and the hearts exposed to anaesthetics.
Conclusion : Volatile anaesthetics in a concentration of 1 MAC can reduce the adhesion of platelets in the coronary system under reduced flow conditions. This action does not arise from vasodilation or inhibition of ischaemic stress.  相似文献   

17.
Background: It has been shown that the depressive effects of both propofol and midazolam on consciousness are synergistic with opioids, but the nature of their interactions on other physiological systems, e. g. respiration, has not been fully investigated. The present study examined the effect of propofol and midazolam alone and in combination with fentanyl on phrenic nerve activity (PNA) and whether such interactions are additive or synergistic. Methods: PNA was recorded in 27 anaesthetised and artificially ventilated rabbits. In three groups, propofol, fentanyl and midazolam were administered intravenously in incremental doses to construct dose-response curves for the depressant effects of each one on PNA. In another two groups, the effect of pretreatment with either fentanyl 1 μg · kg?1 i. v. or midazolam 0.05 mg · kg?1 i. v. on the effects of propofol and fentanyl respectively on PNA were studied. Results: Propofol and fentanyl caused a dose-dependent depression of PNA with complete abolition at the highest total doses of 16 mg · kg?1 i. v. and 32 μg · kg?1 i. v., respectively. In contrast, midazolam in incremental doses to a total of 0.8 mg · kg?1 reduced mean PNA by 63%, but approximately 12% of PNA remained at a total dose as high as 6.4 mg · kg?1. The mean ED50s, calculated from dose-response curves, were 5.4 mg · kg?1, 3.9 μg · kg?1 and 0.4 mg · kg?1 for propofol, fentanyl and midazolam, respectively. Initial doses of either fentanyl 1 μg · kg?1 i. v. or midazolam 0.05 mg · kg?1 i. v. acted synergistically with subsequent doses of either propofol or fentanyl to abolish PNA at total doses of 8 mg · kg?1 and 8 μg · kg?1, respectively. Conclusion: Fentanyl has a synergistic interaction with both propofol and midazolam on PNA and hence potentially on respiration.  相似文献   

18.
Background: Catecholaminergic support is often used to improve haemodynamics in patients undergoing major abdominal surgery. Dopexamine is a synthetic vasoactive catecholamine with beneficial microcirculatory properties. Methods: The influence of perioperative administration of dopexamine on cardiorespiratory data and important regulators of macro- and microcirculation were studied in 30 patients undergoing Whipple pancreaticduodenectomy. The patients received randomized and blinded either 2 μg · kg?1 · min?1 of dopexamine (n=15) or placebo (n=15, control group). The infusion was started after induction of anaesthesia and continued until the morning of the first postoperative day. Endothelin-1 (ET-1), vasopressin, atrial natriuretic peptide (ANP), and catecholamine plasma levels were measured from arterial blood samples. Measurements were carried out after induction of anaesthesia, 2 h after onset of surgery, at the end of surgery, 2 h after surgery, and on the morning of the first postoperative day. Results: Cardiac index (CI) increased significantly in the dopexamine group (from 2.61±0.41 to 4.57±0.78 1 · min?1 · m?2) and remained elevated until the morning of the first postoperative day. Oxygen delivery index (DO2I) and oxygen consumption index (VO2I) were also significantly increased in the dopexamine group (DO2I: from 416±91 to 717±110 ml/m2 · m2; VO2I: from 98±25 to 157±22 ml/m2 · m2), being significantly higher than in the control group. pHi remained stable only in the dopexamine patients, indicating adequate splanchnic perfusion. Vasopressive regulators of circulation increased significantly only in the untreated control patients (vasopressin: from 4.37±1.1 to 35.9±12.1 pg/ml; ET-1: from 2.88±0.91 to 6.91±1.20 pg/ml). Conclusion: Patients undergoing major abdominal surgery may profit from prophylactic perioperative administration of dopexamine hydrochloride in the form of improved haemodynamics and oxygenation as well as beneficial influence on important regulators of organ blood flow.  相似文献   

19.
Background: Halothane inhibits in vitro and in vivo activity of cytochrome P-450 (CYP) 2E1. There are several fluorinated volatile anaesthetics besides halothane, and most of them are defluorinated by CYP2E1. It is unclear whether other fluorinated anaesthetics inhibit the in vivo activity of CYP2E1.
Methods: We compared the inhibitory effects of therapeutic concentrations of four inhalational anaesthetics, halothane, enflurane, isoflurane, and sevoflurane, on chlorzoxazone metabolism in rabbits receiving artificial ventilation.
Results: All four inhalational anaesthetics decreased arterial blood pressure and increased plasma chlorzoxazone concentration. However, no significant differences in the plasma chlorzoxazone concentration were found between the four anaesthetics. The estimated chlorzoxazone clearance increased after beginning inhalation with all four agents, but no significant difference in clearance was noted between agents.
Conclusions: At therapeutic concentrations, the in vivo inhibitory effect on chlorzoxazone metabolism was similar for all four inhalational anaesthetics examined, even though their chemical characteristics and extent of hepatic metabolism differ considerably.  相似文献   

20.
A concept of balanced analgesia using nonsteroidal anti-inflammatory drugs (NSAIDs), paracetamol (acetaminophen), opioids, and corticosteroids can also be used in patients with pre-existing illnesses. NSAIDs are the most effective treatment for acute pain of moderate intensity in children; however, these drugs should be avoided in patients at increased risk for serious side effects, e.g. patients with renal impairment, bleeding tendency, or extreme prematurity. NSAIDs can be given with minimal risks to the younger child with mild to moderate asthma, and, in these patients, the use of steroids can be encouraged; in addition to their antiemetic and analgesic action, a beneficial effect on asthma symptoms can be expected. In the non-intubated child with cerebral trauma, exaggerated sedation caused by opioids and increased bleeding tendency caused by NSAIDs must be avoided. In neonates and small infants, the oral administration of sucrose or glucose is helpful to minimize pain reaction during short uncomfortable interventions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号