首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.

Background  

Patients with THA requiring cup revision for acetabular osteolysis may have a stable stem component without loosening. However, it is unclear whether isolated cup revision halts femoral osteolysis progression.  相似文献   

2.
3.
Little has been published on the outcomes of polyethylene liner exchanges for wear or osteolysis. We assessed 24 patients from our clinic who had an isolated polyethylene liner exchange for wear or osteolysis with retention of the acetabular shell and femoral stem. At a mean 56-month follow-up time, 6 hips (25%) had dislocated. Of these, 2 underwent repeat surgery for recurrent dislocation; 1 had 3 dislocations; 1 had 2 dislocations; and 2 had single dislocations. Seventeen of the remaining patients answered our questionnaire: 13 recovered faster from the polyethylene liner exchange than from the primary arthroplasty; 4 believed that their hips were not as stable, 4 believed the hip did not function as well; and 1 underwent revision for cup loosening. We conclude that polyethylene liner exchanges, with or without femoral head exchange for wear or osteolysis, are associated with a high risk of dislocation and possible decrease in function.  相似文献   

4.

Purpose  

The treatment strategy for pelvic osteolysis with a well-fixed acetabular component after total hip arthroplasty (THA) involves replacing the acetabular cup liner and femoral head, débriding osteolytic lesions, and grafting.  相似文献   

5.
6.
We evaluated the clinical and radiographic results of 67 (64 patients) cementless Duraloc-300 cups for young active patients after a mean follow-up period of 6.2 years. The preoperative mean Harris hip score improved from 46.24 to 96.5 points at 5 years. The survivorship of the cup, using radiographically confirmed aseptic loosening as the end point, was 100% at 5 years. The mean rate of liner wear was 0.125 mm/y (00-0.39 mm/y). Acetabular osteolysis was found in 14% (9 hips) of the 67 hips, and the osteolysis is related to polyethylene wear (P = .0024) and sex (P = .001). Although there was no aseptic loosening of the components, there was a high rate of liner wear of the polyethylene liner and acetabular osteolysis.  相似文献   

7.

Background

Acetabular osteolysis is a major complication of total hip arthroplasty. It is caused in part by wear debris. It has been suggested that this debris can migrate through screw holes in the acetabular component. Solid-backed components have been used to prevent this migration and reduce osteolysis. Newer materials, however, have reduced wear debris. This study aimed to evaluate whether using solid-backed instead of cluster-hole components actually reduces osteolysis. This could open up the possibility of screws being used for greater stability where required.

Methods

This prospective trial randomized 100 patients undergoing cementless total hip arthroplasty to receive either cluster-hole or solid-backed acetabular components. A cementless cup and highly cross-linked polyethylene was used in all patients. Computed tomography, performed at 5 and 10 years after surgery, was assessed by a blinded radiologist for the presence of osteolysis.

Results

Of the 100 patients, 14 required screws for stability, and so were moved into a third “screw” group for per-protocol analysis. At 10 years after surgery, osteolytic lesions were discovered in 18.2% of patients. There was no difference in incidence or volume of osteolysis between patients with cluster-hole acetabular components and those with solid-backed components.

Conclusion

This study reveals a low number of patients with osteolytic lesions 10 years after total hip arthroplasty performed with a modern cup design and highly cross-linked polyethylene liner. There was no clear benefit to using solid-backed acetabular components. Cluster-hole components, however, offer the option of screw augmentation when required.  相似文献   

8.
文立成  李军  马忠泰 《中华外科杂志》2009,47(24):1888-1891
目的 对H/G非骨水泥人工全髋关节置换术后聚乙烯内杯的磨损及髋臼周围骨溶解的情况进行总结.方法 我院1991至1995年共进行58例(65髋)H/G非骨水泥人工全髋关节置换,其中35例(40髋)获得10年以上随访.对这35例(40髋)患者获得随访的病例,采用计算机数字化方法测量髋臼聚乙烯内杯的二维线性磨损.结果 35例40髋均有不同程度的磨损,磨损范围2~8 mm,平均磨损为(0.32±0.31)mm/年.10髋聚乙烯磨损超过6 mm,髋臼假体周围的骨溶解严重,并伴有金属假体的移位,其中5髋聚乙烯内杯完伞磨透,金属股骨头与金属髋臼相接触;5髋聚乙烯内杯磨损严重伴明显骨溶解,内杯松动.2髋聚乙烯内杯脱位.共实施翻修手术12例,包括更换聚乙烯内杯和金属股骨头2例、金属闩杯翻修2例、全髋翻修8例.28髋在髋臼侧发现骨溶解,其中14髋股骨侧亦有骨溶解发生.结论 本组病例所观测到的H/G髋臼聚乙烯内杯的磨损程度超过文献所报道,而且由于磨损产生的大量磨屑,导致假体周围出现明显骨溶解,直接影响到假体的稳定.关节置换术后应定期随访,避免出现严重骨溶解后增加翻修手术的困难.  相似文献   

9.

Purpose

The purpose of this study was to report results at a minimum of 10 years for hydroxyapatite (HA) coating on the titanium arc-sprayed cementless total hip arthroplasty (THA) and to evaluate the impact of cross-linked polyethylene (XLPE) on implant longevity.

Methods

A total of 131 consecutive primary THAs in 123 patients using an AMS acetabular cup and a PerFix HA stem were retrospectively reviewed. Conventional PE was used for 62 hips (CPE group) and cross-linked PE for 69 hips (XLPE group), with mean follow-up periods of 13 and 11.5 years, respectively. These patients were reviewed using the Japanese Orthopaedic Association (JOA) Hip Score and evaluated in terms of PE wear, osteolysis, and implant survival.

Results

The JOA score improved from 42.6 to 83.9 points at the final follow-up. The mean wear rate of 0.12 mm/year in the CPE group was significantly greater than that of XLPE at 0.007 mm/year. In the CPE group, ten (16.1 %) and two (3.2 %) hips, respectively, underwent PE exchange due to severe wear and acetabular revision due to loosening associated with osteolysis. Three patients had revision in the XLPE group: one cup for aseptic loosening, one PE for recurrent dislocation, and one stem for neck fracture. No evident osteolysis was seen in the XLPE group. Kaplan–Meier survivorship with any revision as the end point shows that the 12-year survival rate was 97.7 % for cups, 93.8 % for PE liners, and 99.2 % for stems. Multivariate analysis revealed that the use of XLPE significantly reduced the risk of revision, with the odds ratio (OR) of 4.3.

Conclusions

AMS and PerFix HA components in this series show excellent implant fixation; however, high rates of PE wear and subsequent osteolysis were limiting factors in long-term success. Low wear rates with XLPE suggest improved implant longevity.  相似文献   

10.
Press-fit acetabular cups without screw holes can limit migration of particulate wear debris and reduce risk of acetabular osteolysis and device loosening. The Tri-Spike cup (Biomet, Inc, Warsaw, Ind) includes a titanium alloy plasma spray porous surface and does not require screw fixation. We retrospectively examined the incidence of cup loosening and acetabular osteolysis after implantation of 45 cups (44 patients) with mean follow-up of 7.3 years (range, 4-9 years). Only one patient (one cup) had evidence of less than 1 mm of retroacetabular radiolucency at 3 years (nonprogressive), which was found to remain firmly fixed during revision of the aseptically loosened femoral component. No cups were removed or revised at latest follow-up. Projected Kaplan-Meier survivorship at 9 years was 100% for cup loosening/revision and 97.8% for radiolucency.  相似文献   

11.
The survival of acetabular components depends on several factors: wear, osteolysis and septic or aseptic loosening. Osteolysis seems to be the main cause for concern in cementless arthroplasties. Acetabular osteolysis results from particle debris and segmental unloading of acetabular bone by rigid sockets. We investigated a cementless elastic monoblock socket with regard to acetabular osteolysis and aseptic loosening in a cohort of young patients. We evaluated 158 hip arthroplasties with a minimum follow-up of ten years (ten to 18) and a mean age of 42 years (18–50). The overall revision rate at 14 years was 80% with a 98% survival rate for aseptic loosening. The mean polyethylene wear rate was 0.11 mm/year. Progressive acetabular osteolysis was seen in 3% of patients evaluated. In conclusion, we found low pelvic osteolysis rates, acceptable overall wear rates, satisfactory overall survival and excellent survival rates for aseptic loosening of a cementless elastic monoblock socket in patients younger than 50 years. Ongoing tribology developments and knowledge about acetabular bone adaptations behind acetabular implants will further lower wear and osteolysis rates and optimise survival rates of cementless sockets.  相似文献   

12.

Background

Polyethylene acetabular components are common in hip arthroplasty. Highly cross-linked polyethylene (HXLPE) has lower wear than ultra-high molecular weight polyethylene (UHMWPE). Evidence suggests that wear particles induce inflammation causing periprosthetic osteolysis contributing to implant loosening with wear rates of 0.05 mm/y were considered safe. We aimed to compare incidence and volume of periacetabular osteolysis between HXLPE and UHMWPE using computed tomography.

Methods

Initially, 54 hips in 53 patients were randomized to HXLPE or UHMWPE acetabular liner. At 10 years, 39 hips in 38 patients remained for the radiostereometric analysis' demonstrating significantly lower wear in the HXLPE group. At 12 years, 14 hips in 13 patients were lost to follow-up leaving 25 hips for computed tomography assessment. Images were reconstructed to detect osteolysis and where identified, areas were segmented and volumized.

Results

Osteolysis was observed in 8 patients, 7 from the UHMWPE group and only 1 from the HXLPE group (Fisher exact, P = .042). There was no correlation between the amount of polyethylene wear and osteolysis volume; however, the radiostereometric analysis-measured wear rate in patients with osteolysis from both groups was significantly higher than overall average wear rate.

Conclusion

This data demonstrates lower incidence of periacetabular osteolysis in the HXLPE group of a small cohort. Although numbers are too low to estimate causation, in the context of lower wear in the HXLPE group, this finding supports the hypothesis that HXLPE may not elevate osteolysis risk, and hence does not suggest that HXLPE wear particles are more biologically active than those generated by earlier generations of polyethylene.  相似文献   

13.
《The Journal of arthroplasty》2021,36(11):3697-3702
BackgroundHistorically, aseptic loosening and osteolysis were responsible for most of the revisions among young and more active patients. Ceramic-on-ceramic bearings reduced wear but presented mechanical issues such ceramic fracture or liner chipping during insertion. To prevent this from happening a titanium-encased alumina liner was developed. The aim of this study is to address long-term results of this specific ceramic design.MethodsAll patients received an uncemented acetabular component with ceramic-on-ceramic bearing (94 hips in 77 patients). Patients were prospectively followed over 15 years. Clinical evaluation included the Harris Hip Score and Visual Analog Scale pain scale. Radiographic analysis included integration, osteolysis, and ceramic-related mechanical issues, such as malseating of the insert.ResultsThe studied acetabular design survivorship was 98.9% at a mean follow-up of 17.2 years. One arthroplasty was revised secondary to infection but no cup had loosened or migrated during the study. Only 1 cup showed complete radiolucent lines. There was no fracture of any ceramic component in the study group. Malseating was present in 12 acetabular components (12.8%). No osteolysis was observed with over 15 years of follow-up.ConclusionIn conclusion, this acetabular component demonstrates a favorable clinical and radiological outcome with over 15 years of follow-up. Osteolysis was not observed and incomplete seating of the titanium-sleeved ceramic liner did not lead to mechanical problems.  相似文献   

14.

Background  

First-generation modular titanium fiber-metal-coated acetabular components had high rates of wear, pelvic osteolysis, and liner dissociation. Second-generation components were designed to reduce the incidence of these problems but it is unclear whether the changes achieved these goals.  相似文献   

15.
16.

Purpose

Whilst excellent long-term results with contemporary uncemented stems have been reported for total hip arthroplasty in young patients, the survival rates for the whole reconstruction are often compromised by high failure rates on the acetabular site due to peri-acetabular osteolysis and accelerated wear.

Methods

In patients 60 years old or younger, we retrospectively reviewed the results at a minimum of ten years of 89 consecutive uncemented total hip replacements in 88 patients using the press-fit Fitmore acetabular component in combination with the CLS Spotorno stem and a 28-mm Metasul metal-on-metal articulation or a 28-mm alumina ceramic on conventional polyethylene bearing. The mean age at the time of surgery was 49 years (range, 25–60). The mean clinical and radiological follow-up was 12 years (range, 10–15).

Results

Six patients (six hips) died and two patients (two hips) were lost to follow-up. Five hips were revised: one for deep infection, one for peri-prosthetic femoral fracture, and one for aseptic stem loosening. In two hips an isolated revision of the acetabular liner was performed (one for recurrent dislocation and one for unexplained pain). No revision was performed for accelerated wear, osteolysis or aseptic loosening of the acetabular shell. We could not detect peri-acetabular osteolysis visible on plain radiographs in those hips evaluated radiographically. The Kaplan-Meier survival with revision for any reason as the endpoint was 94% (95% confidence interval, 86–97) at 12 years.

Conclusions

The survival rates and the radiological outcomes with this implant combination in this young and active patient group are encouraging when compared to the results reported for other uncemented cups in this age group.  相似文献   

17.

Introduction

A flattened cup was designed to create a more physiological load transfer to the pelvic bone compared to hemispherical cups, and to allow more bone contact compared to low-profile’ spherical cups. To investigate these theoretical advantages and the potential influence of the quality of the acetabular bone, a clinical study was performed in patients with osteoarthritis (OA) and inflammatory arthritis (IA). The aims of the study were (1) to evaluate the fixation of the cup, postoperatively and later when osseous integration should have taken place, (2) to assess perioperative complications such as acetabular fractures and (3) to monitor the polar gap, a potential risk factor for osteolysis.

Patients and methods

A prospective study was performed on all consecutive OA and IA patients with an indication for primary total hip arthroplasty (THA). Three hundred and nine OA patients (340 hips) and 65 IA patients (76 hips) were included. The acetabular component was the flattened press-fit EPF-PLUS® cup, the femoral component the tapered cementless Zweymueller SL-PLUS® stem. All revisions and complications were recorded. Clinical and radiographical evaluation was performed on regular basis during 6–10 years.

Results

The incidence of early loosening of the cup was 0 out of 340 in the OA group and 1 out of 76 in the IA group. The incidence of acetabular fractures was 7 out of 340 in the OA group and 3 out of 76 in the IA group. Failure rate for the acetabular component due to aseptic loosening or osteolysis after 6–10 years was 0% in the OA group and 4.8% in the IA group. In all cases available for follow-up the polar gap had disappeared and full osseous integration had taken place in both the groups.

Interpretation

This study shows that the flattened press-fit acetabular component creates adequate initial mechanical stability to allow osseous integration and that the cup can be safely used in both OA and IA patients. However, after 6–10 years, in the IA group failure of the cup due to aseptic loosening occurred once and failure due to osteolysis occurred three times, while these type of failures did not occur in the OA group.  相似文献   

18.

Background and purpose

Uncemented acetabular components in primary total hip arthroplasty (THA) are commonly used today, but few studies have evaluated their survival into the second decade in young and active patients. We report on a minimum 10-year follow-up of an uncemented press-fit acetabular component that is still in clinical use.

Methods

We examined the clinical and radiographic results of our first 121 consecutive cementless THAs using a cementless, grit-blasted, non-porous, titanium alloy press-fit cup (Allofit; Zimmer Inc., Warsaw, IN) without additional screw fixation in 116 patients. Mean age at surgery was 51 (21–60) years. Mean time of follow-up evaluation was 11 (10–12) years.

Results

At final follow-up, 8 patients had died (8 hips), and 1 patient (1 hip) was lost to follow-up. 3 hips in 3 patients had undergone acetabular revision, 2 for deep infection and 1 for aseptic acetabular loosening. There were no impending revisions at the most recent follow-up. We did not detect periacetabular osteolysis or loosening on plain radiographs in those hips that were evaluated radiographically (n = 90; 83% of the hips available at a minimum of 10 years). Kaplan-Meier survival analysis using revision of the acetabular component for any reason (including isolated inlay revisions) as endpoint estimated the 11-year survival rate at 98% (95% CI: 92–99).

Interpretation

Uncemented acetabular fixation using the Allofit press-fit cup without additional screws was excellent into early in the second decade in this young and active patient cohort. The rate of complications related to the liner and to osteolysis was low.Uncemented acetabular components are widely used all over the world. A variety of these components have been associated with excellent short- to medium-term clinical and radiographic outcomes (Hallan et al. 2010, Howard et al. 2011). During the second decade of use, a number of cementless cup designs have shown durable fixation, but problems related to wear and osteolysis often compromise the results, and the surgeon can face serious problems in revision surgery because of extensive bone loss. This is a particular problem with young and active patients (Kim et al. 2012). Currently, there are few reports on the survival of contemporary uncemented cups that are still in clinical use in young patient cohorts with a minimum of 10 years of follow-up (Akbar et al. 2009, Kim et al. 2012), despite being used frequently in this group of patients.We evaluated the ten- or more-year results of an independent series of the non-porous, uncemented, press-fit Allofit cup in young patients (≤ 60 years old) implanted without any additional fixation (screws) and compared the results with those reported in the literature.  相似文献   

19.

Introduction

Many kind of hydroxyapatite-coated cups were used, with favorable results in short term studies; it was supposed that its use could improve osteointegration of the cup, enhancing thus stability and survivorship. The purpose of this study is to analyze the long term behavior of the hemispheric HA coated, Dual Radius Osteonics cup and to discuss the way of failure through the exam of the revised components and of both periacetabular and osteolysis tissue.

Materials and Methods

Between 1994 and 1997, at the Department of Orthopedic Sciences of the Insubria University, using the posterolateral approach, were implanted 276 Dual Radius Osteonics® in 256 patients, with mean age of 63 years.

Results

At a mean follow-up of 10 years (range 8–12 years), 183 cups in 165 patients, were available for clinical and radiographical evaluation. 22 Cups among the 183 were revised (11%). The cause of revision was aseptic loosening in 17 cases, septic loosening in one case, periprosthetic fracture in another case, osteolysis and polyethylene wear in two cases and, finally, recurrent dislocations in the last one. In the remaining patients, mean HHS increased from a preoperative value of 50,15 to a postoperative value of 92,69. The mean polyethylene wear was 1,25 mm (min. 0,08, max. 3,9 mm), with a mean annual wear of 0,17 mm. The mean acetabular migration on the two axis was 1,6 mm and 1,8 mm. Peri-acetabular osteolysis were recorded in 89% of the implants (163 cases). The cumulative survivorship (revision as endpoint) at the time was 88,9%.

Conclusion

Our study confirms the bad behavior of this type of cup probably related to the design, to the method of HA fixation. The observations carried out on the revised cup confirm these hypotheses but did not clarify if the third body wear could be a further problem. Another interesting aspect is the high incidence of osteolysis, which are often asymptomatic becoming a problem for the surgeon as the patient refuses the possibility of a revision.  相似文献   

20.

Background  

Liner exchange and bone grafting are commonly performed for wear and osteolysis around well-fixed modular acetabular components that otherwise would require structural allografting and revision THA. However, liner exchange in the face of substantial lysis around TKA has been performed rarely with reports of failure rates of up to 25% at 3 year followup.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号