1.

Purpose

The objective of this study was to determine the value of high-field magnetic resonance imaging and to clarify the characteristics of each image among three-dimensional gradient echo (3D-GRE), two-dimensional spin echo (2D-SE) and inversion recovery (2D-IR) sequences used as contrast-enhanced T1-weighted images for stereotactic irradiation treatment planning of sellar lesions.

Materials and methods

Pulse sequences of 2D-SE and 3D-spoiled gradient recalled acquisition in the steady state (3D-SPGR) using GRE at 1.5 T and 2D-IR and 3D-fast SPGR (3D-FSPGR) at 3 T after injection of contrast material were acquired for 14 small pituitary tumors. As quantitative methods, signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were evaluated using a region-of-interest analysis.

Results

There was no significant difference in SNR between 1.5-T SPGR and 3-T FSPGR, while 3-T IR was superior to 1.5-T SE. The 2D-SE and -IR provided significantly better CNR than 3D-GRE between tumor and normal structures.

Conclusions

Three Tesla was found to be superior to 1.5 T in distinguishing tumors from the normal sellar structure. Optimal dose planning will utilize each advantage of imaging; 3D-GRE allows high-resolution acquisition and 2D-SE and -IR can offer better tissue contrast.  相似文献   

2.
We evaluated the newly developed whole-brain, isotropic, 3-dimensional turbo spin-echo imaging with variable flip angle echo train (SPACE) for contrast-enhanced T(1)-weighted imaging in detecting brain metastases at 3 tesla (T). Twenty-two patients with suspected brain metastases underwent postcontrast study with SPACE, magnetization-prepared rapid gradient-echo (MP-RAGE), and 2-dimensional T(1)-weighted spin echo (2D-SE) imaging at 3T. We quantitatively compared SPACE, MP-RAGE, and 2D-SE images by using signal-to-noise ratios (SNRs) for gray matter (GM) and white matter (WM) and contrast-to-noise ratios (CNRs) for GM-to-WM, lesion-to-GM, and lesion-to-WM. Two blinded radiologists evaluated the detection of brain metastases by segment-by-segment analysis and continuously-distributed test. The CNR between GM and WM was significantly higher on MP-RAGE images than on SPACE images (P<0.01). The CNRs for lesion-to-GM and lesion-to-WM were significantly higher on SPACE images than on MP-RAGE images (P<0.01). There was no significant difference in each sequence in detection of brain metastases by segment-by-segment analysis and the continuously-distributed test. However, in some cases, the lesions were easier to detect in SPACE images than in other sequences, and also the vascular signals, which sometimes mimic lesions in MP-RAGE and 2D-SE images, were suppressed in SPACE images. In detection of brain metastases at 3T magnetic resonance (MR) imaging, SPACE imaging may provide an effective, alternative approach to MP-RAGE imaging for 3D T(1)-weighted imaging.  相似文献   

3.
Objective. The objective of this study was to determine the value of MRI in the detection of degenerative bone marrow abnormalities in an animal osteoarthritis model. Design. In 10 dogs with experimentally induced unilateral osteoarthritis of the knee, MRI was performed using two-dimensional spin-echo (2D-SE) and three-dimensional gradient-echo (3D-GE) imaging. Contrast enhanced T1-weighted 2D-SE sequences were also obtained after injection of gadolinium-DTPA. The results were compared with the gross and histopathologic findings and with radiography. Results. Histopathologic specimens revealed 21 osteosclerotic lesions and 5 intraosseous cysts. On 2D-SE images, 24 of 26 lesions were detected, while 21 of 26 lesions were identified on 2D-GE sequences. Radiography, including conventional tomography, demonstrated 9 of 26 lesions. Regardless of the sequence weighting, all osteosclerotic lesions appeared hypointense on MRI. Signal loss in bone sclerosis resulted primarily from the reduction of intact fat marrow, the increased bone density being of secondary importance. Quantitative signal analysis allowed approximate estimation of the grade of sclerosis. On postcontrast images, sclerotic bone remained hypointense, although significant but non-specific enhancement relative to the normal fat marrow was observed. The extent of contrast enhancement did not correlate with the grade of osteosclerosis. All five cysts were readily diagnosed by MRI. Cysts displayed either central or marginal contrast enhancement within their cavities. Conclusions. MRI provides a sensitive method for the diagnosis of osteoarthritic bone abnormalities, allowing their differentiation from most non-degenerative subarticular lesions.  相似文献   

4.
Sun J  Zhang S  Jiang D  Zhang D  Xu X 《Clinical imaging》2008,32(2):103-108
PURPOSE: Although fluid-attenuated inversion-recovery (FLAIR) magnetic resonance imaging (MRI) is widely applied to diagnose central nervous system diseases, its role in diagnosis of intraspinal tumors is unclear. In this study, we evaluated the potential clinical application of a turbo FLAIR sequence for imaging of intraspinal tumors. MATERIALS AND METHODS: Forty-eight consecutive patients with intraspinal tumors underwent MRI with turbo FLAIR and turbo spinal echo (TSE) sequences. Turbo FLAIR images were then qualitatively and quantitatively compared with T2-weighted TSE images. RESULTS: Turbo FLAIR images were evaluated as superior to T2-weighted TSE images for image artifact, extradural tumor conspicuity, and intradural extramedullary tumor conspicuity and detection. Intramedullary tumor conspicuity with turbo FLAIR was less than T2-weighted TSE. Similar capabilities in detection of extradural and intramedullary tumors were found between turbo FLAIR and T2-weighted TSE. Turbo FLAIR and T2-weighted TSE displayed similar normal spinal cord signal-noise ratio (SNR) and tumor-to-cerebrospinal fluid (CSF) contrast-to-noise ratio (CNR). In addition, turbo FLAIR yielded significantly higher tumor-to-CSF contrast than T2-weighted TSE. However, tumor SNR, tumor-to-normal spinal cord contrast and CNR with turbo FLAIR images were lower than those with T2-weighted TSE images. CONCLUSION: This study demonstrated (a) a superiority of turbo FLAIR to T2-weighted TSE in displaying and detecting intradural extramedullary tumors, (b) a superiority of turbo FLAIR to T2-weighted TSE in demonstrating extradural tumors, and (c) less usefulness in displaying intramedullary tumors with turbo FLAIR than with T2-weighted TSE.  相似文献   

5.
The purpose of this study was to evaluate a three-dimensional (3D) constructive interference in steady state (CISS) sequence in the assessment of syringomyelia. Eleven patients with syringomyelia were prospectively studied with magnetic resonance imaging. All patients underwent sagittal imaging with T1- and T2-weighted spin-echo (SE), and 3D-CISS sequences. The SE and 3D-CISS images, as well as multiplanar reconstruction (MPR) images of the 3D-CISS sequence, were analyzed with regard to image quality, degree of artifacts, visualization of the extent and internal structure of the syringomyelia, and contrast-to-noise ratio (CNR) of the fluid within the syringomyelia. Contrast between the spinal cord and cerebrospinal fluid (CSF), as well as delineation was significantly poorer for the T1-weighted SE sequence than for the 3D-CISS sequence (P < 0.01), while there was no significant difference between the T2-weighted SE sequence and the 3D-CISS sequence. Artifacts induced by CSF flow were significantly more for the T2-weighted SE sequence than for the 3D-CISS sequence (P < 0.01). Although the extent of syringomyelia was delineated equally among the three sequences in 9 of 11 patients, it was better for the 3D-CISS sequence than for the SE sequences in the remaining two. Septation and communication between the cavities were best detected by the 3D-CISS MPR images. The CNR of the 3D-CISS sequence was significantly higher than that of the SE sequence (P < 0.01). The 3D-CISS sequence demonstrates the extent and internal structures of syringomyelia better than conventional SE sequences and should be added to SE sequences in the evaluation of syringomyelia.  相似文献   

6.
Diagnostic accuracy of contrast-enhanced CT, unenhanced MR imaging, and MR images enhanced with superparamagnetic iron oxide was evaluated in 10 patients with histologically proved hepatic metastases. First, diagnostic performance of the imaging technique with respect to the ability of radiologists to recognize the presence or absence of a metastasis was measured by using receiver-operating-characteristic (ROC) analysis of single images. Second, the total number of lesions (N = 108) detected by "complete" CT and MR examinations was counted. Finally, lesion-liver contrast-to-noise ratios (CNR) were measured in all MR sequences. The area under the ROC curve was .67 +/- .03 for contrast-enhanced CT, .81 +/- .07 for the unenhanced SE 260/14 sequence, and .92 +/- .01 for the iron oxide-enhanced SE 1500/40 sequence. The enhanced SE 1500/40 sequence yielded significantly (p less than .005) greater accuracy than did contrast-enhanced CT. The same sequence detected significantly (p less than .05) more lesions than all other imaging techniques (19% more than the best unenhanced MR sequence and 36% more than contrast-enhanced CT). The enhanced SE 1500/40 sequence also yielded the highest CNR value (19.5 +/- 10.2) of all MR sequences. These results indicate that iron oxide-enhanced MR imaging is a superior imaging technique for the detection of hepatic lesions.  相似文献   

7.
目的 评价化学位移成像和反转恢复快速自旋回波对肝脏病变的检出能力。材料与方法 45例肝脏病变患者在进行常规SE T1WI和半傅立叶采集单次激发快速自旋回波(half-fFourier acquistition single-shot turbo spin-echo,HASTE)T2WI的同时,加用化学位移成像T1WI和反转恢复HASTE(IR-HASTE)T2WI。比较图像的信噪比(SNR)、肝脾对比噪声比(L-S CNR)、病灶对比噪声比(CNR)及病灶检出率。结果 化学位移成像T1WI的SNR、L-S CNR及SE T1WI均无显著性差异(P>0.05),但却能检出SET1WI无法显示的局灶性脂肪浸润和脂肪肝。IR-HASTE的SNR与HASTE相近(P>0.05),前者的L-S CNR及实性病灶的CNR均显著高于后者(P<0.05),特别是对较小的实质性病灶。结论 化学位移成像T1WI能提高肝脂肪成分的检出率,IR-HASTE的SNR与HASTE相近(P>0.05),前者的L-S CNR及实性病灶的CNR均显著高于后者(P<0.05),特别是对较小的实质性病灶。结论 化学位移成像T1WI能提高肝脂肪成分的检出率,IR-HASTE能提高肝实性病变的检出率,两种成像方法可作为常规肝脏检查方法的有力补充。  相似文献   

8.
PURPOSE: To compare breath-hold fast-recovery fast spin echo (FR-FSE) and non-breath-hold fast spin echo (FSE) T2-weighted sequences for hepatic lesion conspicuity and image quality at MR imaging. MATERIALS AND METHODS: Fifty-nine patients with known or suspected liver lesions underwent hepatic MR imaging by using a breath-hold FR-FSE T2-weighted sequence with and without fat suppression and a non-breath-hold FSE T2-weighted sequence with and without fat suppression. Quantitative analysis was made with measurements of the signal intensity of the liver, spleen, background noise, and up to three liver lesions, as well as calculations of the liver signal-to-noise ratio (SNR) and the liver-to-lesion contrast-to-noise ratio (CNR) for each sequence. Qualitative analysis was made for image quality and the number of lesions identified. Statistical analysis was performed by using a single-tailed paired Student's t test with a 95% confidence interval. RESULTS: SNR and CNR were significantly higher (P<.05) for FSE with fat suppression than for FR-FSE with fat suppression. No statistically significant difference was seen in terms of SNR and CNR between non-fat-suppressed FSE and FR-FSE sequences. Lesion conspicuity, liver edge sharpness, and clarity of vessels were superior and ghosting was less with the FR-FSE sequences compared with the FSE sequences. CONCLUSION: Breath-hold FR-FSE technique is a reasonable alternative in T2-weighted imaging of the liver.  相似文献   

9.
目的 探讨3D超短回波时间(UTE)舣回波脉冲序列成像的相关成像参数及后处理技术对图像质量的影响.方法 对主要含短T2成分的人于燥股骨标本及一组健康志愿者的胫骨、膝关节、踝部肌腱行MR 3D UTE舣回波脉冲序列成像.通过计算、比较图像的信噪比(SNR)或对比噪声比(CNR)及对图像伪影的分析,探讨系统内部不同轨道延迟时间(-6、-3、-2、-1、0、1、2、3 s)、不同反转角(4°、8°、12°、16°、20°、24°)、不同TE1(0.08、0.16、0.24、0.35 ms)及不同后处理技术(超短回波减影差异图、容积超短回波减影差异图)对图像质量的影响.结果 骨皮质、骨膜、半月板、肌腱、韧带等在UTE图像上表现为高信号.所设的不同轨道延迟时间中,获得最佳SNR的轨道延迟时阳间为2 s.活体人UTE成像的最佳反转角为8°~12°.不同TE1时间的图像质量不同,TE1为0.08 ms时,图像的CNR最佳.随TE1时阳延长,图像伪影逐渐增多.将原始双回波图经多平面重组后再相减(容积超短回波减影差异图),图像SNR明显增加.结论 短T2成分在3D UTE双回波脉冲序列成像上表现为高信号.通过改变反转角和将2次回波图像经MPR后再相减可增加图像SNR.缩短TE1时间可增加图像质量.
Abstract:
Objective To investigate the effect of imaging parameters and postprocessing methods on the quality of MR imaging of short T2 components with 3D ultrashort TE (UTE) double echo pulse sequence. Methods 3D UTE double echo pulse sequence was performed on dry human femoral specimen and the tibial diaphyses, knee joints, and tendons of ankles of a group of healthy volunteers. To investigate the effect of different trajectory delays of the imaging system(-6, -3, -2, - 1,0, 1,2, 3 s), different flip angles(4°, 8°, 12°, 16°, 20°, 24°), different TEs (0. 08, 0. 16, 0. 24, 0. 35 ms)and different postprocessing methods(difference imaging of subtracted volume and non-volume UTE)on the 3D UTE MR imaging quality, the SNR and CNR were calculated and compared, and the artifacts of the images were analysed. Results The cortical bone, periosteum, tendon and meniscus showed high signal intensity on the images of UTE pulse sequence. The best SNR was acquired with 2 s trajectory delay. The best flip angle was 8° to 12° for the human UTE imaging in vivo. The highest CNR was obtained from the TE of 0. 08 ms. The longer the TE was, the more artifacts appeared. The SNR of difference imagewas improved when image subtraction was performed afer multiplanar reconstruction (MPR) of the primary double echo images.Conclusions The short T2 components show high signal intensity on the MRI of 3D UTE double echo pulse sequence. The imaging quality can be improved by shortening TE, using appropriate flip angle and performing subtraction for difference image after MPR of the primary double echo images.  相似文献   

10.
As inversion-recovery (IR) technique improves T1 contrast at high field strength, signal enhancement by T1-shortening contrast media may be affected. To clarify the different enhancement properties at 3.0 T, the authors compared T1-weighted sequences. Twelve contrast-enhancing lesions were investigated by spin-echo (SE), inversion recovery fast spin-echo (IR-FSE), two-dimensional gradient-echo (2D GE), and magnetization-prepared three-dimensional gradient-echo (3D GE) sequences and evaluated by comparing signal-intensity enhancements within the lesions. In addition, signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were measured. On average, signal enhancement of the lesions amounted to 60% for SE, 57% for IR-FSE, 32% for 2D GE, and 35% for 3D GE images. CNR of gray matter versus white matter was significantly higher for IR SE and GE imaging than for genuine SE and 2D GE acquisitions (Wilcoxon test), while 2D GE imaging alone had an excellent SNR. As IR-FSE images provide an excellent CNR for gray and white matter in the brain and contrast enhancement performs almost similarly well compared with SE imaging, this technique appears to be well suited for T1-weighted neuroimaging without and with contrast enhancement at 3.0 T. However, the inherent blurring of the IR-FSE can lead to poor performance for very small lesions.  相似文献   

11.
PURPOSE: To evaluate and compare the diagnostic accuracy of appropriate magnetic resonance (MR) sequences in the detection of cartilage lesions at 1.5T and 3.0T. MATERIAL AND METHODS: Twelve chondral defects of varying depths, widths, and locations were created in the retropatellar hyaline cartilage in six sheep cadaver limbs. Axial images employing three fat-suppressed imaging sequences--(1) a T2-weighted fast spin-echo (FSE) sequence, (2) a two-dimensional (2D) and (3) three-dimensional (3D) gradient-echo (GE) sequence at 1.5T and 3.0T using an extremity quadrature coil--were evaluated by three experienced radiologists. Statistical analysis of the results consisted of receiver operating characteristics (ROC) and significant testing using the bivariate chi-square test. In addition, signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were evaluated with significance testing using the Wilcoxon test. RESULTS: The 3D GE sequence compared favorably with other sequences at 3.0T and 1.5T (Az=0.88 at 3.0T and Az=0.85 at 1.5T) missing only one small grade 2 lesion. 2D GE imaging was inferior to 3D imaging at both field strengths (P<0.05) in general. However, compared to 1.5T, lesion detectability was improved at the higher magnetic field of 3.0T (Az=0.81 and 0.73 at 3.0T and 1.5T, respectively). FSE images showed significantly inferior sensitivity and less anatomical detail compared to the GE sequences at both field strengths (Az=0.64 and 0.72 at 3.0T and 1.5T, respectively; P<0.05). However, compared to 1.5T, lesion detectability SNR and CNR values were superior in all sequences tested at 3.0T. CONCLUSION: MRI at 3.0T improves SNR and CNR significantly in the most common sequences for cartilage MRI, resulting in an improvement in chondral lesion detection. GE imaging therefore allows resolution to be increased in an acceptable time manner for patient comfort, and the 3D GE fat-suppressed sequence at 3.0T appears to be best suited for cartilage imaging in a clinical setting.  相似文献   

12.
The purpose of this study was to compare 3T and 7T signal-to-noise and contrast-to noise ratios of clinical sequences for imaging of the ankles with optimized sequences and dedicated coils. Ten healthy volunteers were examined consecutively on both systems with three clinical sequences: (1) 3D gradient-echo, T(1)-weighted; (2) 2D fast spin-echo, PD-weighted; and (3) 2D spin-echo, T(1)-weighted. SNR was calculated for six regions: cartilage; bone; muscle; synovial fluid; Achilles tendon; and Kager's fat-pad. CNR was obtained for cartilage/bone, cartilage/fluid, cartilage/muscle, and muscle/fat-pad, and compared by a one-way ANOVA test for repeated measures. Mean SNR significantly increased at 7T compared to 3T for 3D GRE, and 2D TSE was 60.9% and 86.7%, respectively. In contrast, an average SNR decrease of almost 25% was observed in the 2D SE sequence. A CNR increase was observed in 2D TSE images, and in most 3D GRE images. There was a substantial benefit from ultra high-field MR imaging of ankles with routine clinical sequences at 7T compared to 3T. Higher SNR and CNR at ultra-high field MR scanners may be useful in clinical practice for ankle imaging. However, carefully optimized protocols and dedicated extremity coils are necessary to obtain optimal results.  相似文献   

13.
PURPOSE: To evaluate the efficacy of ferucarbotran in T2-weighted (T2W) fast spin-echo (FSE) and T2*W gradient-echo (GRE) sequences for characterizing focal liver lesions. MATERIALS AND METHODS: In 68 patients, 46 malignant and 22 benign focal liver lesions were evaluated. Precontrast (NCE) T2W FSE images and contrast-enhanced (CE) T2W FSE and T2*W GRE images were obtained on a 1.5T MR system. Based on signal intensity (SI) measurements in focal lesions and liver parenchyma, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for all sequences. The percentage of SI loss (PSIL) in focal lesions after contrast agent (CA) application was calculated for the T2W FSE sequence. Qualitative analyses were performed to assess image quality and lesion conspicuity obtained with the CE-T2W FSE and CE-T2*W GRE sequences. RESULTS: The mean PSIL was higher in solid benign lesions than in malignant lesions (39.6% vs. 3.2%, P<0.05). With a threshold PSIL of 25%, the sensitivity and specificity for characterizing malignant lesions were 97.8% and 92.9%, respectively. The mean CNR of the malignant lesions was higher in the CE-T2*W sequence than in the CE- and NCE-T2W FSE sequences (29.9 vs. 22.7 (P<0.01) vs. 12.8 (P<0.01)). CE-T2*W images showed a superior image quality and lesion conspicuity (P<0.05) compared to the CE-T2W FSE sequence. CONCLUSION: The PSIL can be an accurate tool for characterizing benign and malignant lesions. The addition of a CE-T2*W GRE sequence is helpful for the detection and characterization of malignant lesions.  相似文献   

14.
增强后液体衰减反转恢复序列MRI在颅内肿瘤诊断中的应用   总被引:5,自引:0,他引:5  
目的 评价增强后液体衰减反转恢复序列(FLAIR)在颅内肿瘤诊断中的应用价值。方法 104例颅内肿瘤,经手术、病理证实共有病灶124个。分别行增强前、后T1WI和FLAIR扫描。由2名有经验的放射科医生对所有病例进行评价。评价内容包括:增强例数、增强病灶个数及强化病灶部位;对比度及增强率;病变大小和范围。结果行统计学分析。结果 104例中,增强后FLAIR(CEFLAIR)成像、增强SE T1WI(CET1WI)均显示98例有强化。CEFLAIR成像检出了117个强化灶,CE T1W1检出了120个。4个病灶仅在CEFLAIR显示而CET1WI未显示。另有7个病灶仅在CET1WI显示而CEFLAIR未显示。两者之信噪比(SNR)差异无统计学意义(t=1.10,P=0.270),脑灰白质对比度(GMC)、对比噪声比(CNR)及强化率(CER)差异均有统计学意义(t值分别为2.46、7.10、9.67,P值分别为0.015、0.000、0.000)。在显示病灶大小上,CEFLAIR成像明显大于CET1WI(t=4.13,P=0.000),在病灶范围上,有62例CEFLAIR成像较CET1WI大。CEFLAIR成像对位于脑沟、凸面、侧脑室旁及侧脑室内病灶的检出优于CET1WI,而对大脑半球及第四脑室内的病灶的显示不如CET1WI。结论 CEFLAIR成像与CET1WI比较,强化病灶数,两者无明显差别,强化程度CET1WI明显高于CEFLAIR成像,但两者对不同部位病灶的显示有明显差异,CEFLAIR成像显示病灶大小和范围明显大于CET1WI。两种序列相互补充,建议将CEFLAIR成像序列列为增强后常规序列。  相似文献   

15.
目的评价质子加权预饱和脂肪抑制序列(PDW PFS)对肛瘘显示的准确性及图像质量的清晰性,探讨PDW PFS在肛瘘中的应用价值。资料与方法 20例经手术证实的肛瘘患者术前进行MRI检查,序列包括T1WI、T2W频谱选择性衰减反转恢复序列(SPAIR)和PDW PFS。MRI检查前均向患者肛管直肠内置入肛肠水囊以撑开肛管和直肠。获得图像后,观察患者的瘘管、内口和肛周脓肿,评估和比较MRI各序列显示的瘘管、内口、脓腔,并对PDW PFS和T2W SPAIR序列瘘管的信号强度(SI)、信噪比(SNR)及瘘管与周围肌肉的对比噪声比(CNR)进行测量及比较。结果 PDW PFS序列显示瘘管(100%)、内口(95.7%)、肛周脓肿(100%)的准确率较T1WI及T2WSPAIR序列为高。Kruskal Wallis检验显示上述各序列对瘘管(χ2=6.95,P<0.05)及内口(χ2=31.53,P<0.05)的显示具有显著统计学差异,PDW PFS序列显示瘘管及内口最多。PDW PFS序列SI、SNR值和CNR值均显著高于T2W SPAIR序列(P<0.05)。结论 PDW PFS成像技术具有较高的图像SNR和CNR,更易认识辨别瘘管和内口,可以作为一种新的无创性磁共振成像技术应用于肛瘘成像。  相似文献   

16.
Objective. To identify an optimal pulse sequence for in vitro imaging of hyaline cartilage at 0.5 T. Materials and methods. Twelve holes of varying diameter and depth were drilled in cartilage of two pig knees. These were submerged in saline and scanned with a 0.5-T MR system. Sixteen T1-weighted gradient echo (GE), two T2-weighted GE, and 16 fast spin echo sequences were used, by varying repetition time (TR), echo time (TE), flip angle (FA), echo train length, profile order, and by use of fat saturation. Contrast-to-noise ratios (CNR) of cartilage versus saline solution and cartilage versus subchondral bone were measured. Cartilaginous lesions were evaluated separately by three independent observers. Interobserver variability and correlation between the quantitative and qualitative analyses were calculated. Results. The mean CNRs of two specimens of cartilage versus saline solution ranged from 6.3 (±2.1) to 27.7 (±2.5), and those of cartilage versus subchondral bone from 0.3 (±0.2) to 22.5 (±1.4). The highest CNR was obtained with a T1-weighted spoiled 3D-GE technique (TR 65 ms, TE 11.5 ms, FA 45°). The number of lesions observed per sequence varied from 35 to 69. Observer agreement was fair to good. The T1-weighted spoiled GE sequences with a TR of 65 ms, TE of 11.5 ms and FA of 30° and 45° were significantly superior to the other 34 sequences in the qualitative analysis. Conclusion. T1-weighted spoiled 3D-GE sequences with a TR of 65 ms, a TE of 11.5 ms, and a FA of 30–45° were found to be optimal for in vitro imaging of cartilage at 0.5 T.  相似文献   

17.
PURPOSE: To compare signal-to-noise ratio (SNR), contrast-to-noise (CNR) ratio, and diagnostic accuracy of a newly developed saturation recovery (SR)-TrueFISP-two-dimensional (2D) sequence with an SR-TurboFLASH-2D sequence. MATERIALS AND METHODS: In seven healthy subjects and nine patients with coronary artery disease (CAD), contrast-enhanced perfusion imaging (with Gd-DTPA) was performed with SR-TrueFISP and SR-TurboFLASH sequences. Hypoperfused areas were assessed qualitatively (scale = 0-4). Furthermore, SNR and CNR were calculated and semiquantitative perfusion parameters were determined from signal intensity (SI) time curves. Standard of reference for patient studies was single-photon emission computer tomography (SPECT) and angiography. RESULTS: The perception of perfusion deficits was superior in TrueFISP images (2.6 +/- 1.0) than in TurboFLASH (1.4 +/- 0.6) (P < 0.001). Phantom measurements yielded increased SNR (143 +/- 34%) and CNR (158 +/- 64%) values for TrueFISP. In patient/volunteer studies SNR was 61% to 100% higher and signal enhancement was 110% to 115% higher with TrueFISP than with TurboFLASH. Qualitative and semiquantitative assessment of perfusion defects yielded higher sensitivities for detection of perfusion defects with TrueFISP (68% to 78%) than with TurboFLASH (44% to 59%). CONCLUSION: SR-TrueFISP-2D perfusion imaging provides superior SNR and CNR than TurboFLASH imaging. Moreover, the dynamic range of SIs was found to be higher with TrueFISP, resulting in an increased sensitivity for detection of perfusion defects.  相似文献   

18.
目的;比较八次激发SE-EPI与呼吸门控FSE及SSFSE T2WI在肝脏的应用。方法:对14例志愿者及21例肝病患者行上腹部呼吸门控FSE及SSFSE和屏气八次激发SE-EPI扫描。所有T2WI序列均运用脂肪抑制技术。定量分析肝脏、病灶的信噪比及肝脏-病灶的对比噪声比,评价各序列的图像质量及伪影。结果:八次激发SE-EPI与SSFSE及FSE在肝脏及病灶信噪比,肝脏-病灶对比度噪声比和图像质量方面无明显差异(P>0.05)。其磁敏感伪影较FSE及SSFSE重(P<0.01),SE-EPI化学位移伪影与SSFSE及FSE相比无明显差别(P>0.05)。SE-EPI及FSE运动伪影明显比SSFSE重(P<0.01),但SE-EPI运动伪影与FSE相比无明显差别(P>0.05)。SE-EPI与FSE及SSFSE的图像质量无明显差别(P>0.05)。结论:八次激发SE-EPI能够在较短时间里提供较高质量的上腹部T2WI。被检查者在扫描时可自由平静呼吸或屏气,可作为肝脏T2WI的补充序列。  相似文献   

19.
MR imaging of primary epidermoid tumors   总被引:2,自引:0,他引:2  
The magnetic resonance (MR) imaging characteristics of five primary intradural epidermoid tumors are described. At 0.35 T, the most consistent finding on spin echo imaging was a tumor signal intensity that differed from brain and CSF. On T1-weighted images [repetition time (TR) 0.5 s, echo time (TE) 30-40 ms] all tumors exhibited a signal intensity intermediate between brain and CSF. On moderately T2-weighted images (TR 2.0 ms, TE 60-80 ms) the tumor signal intensity was greater than brain and CSF in all cases. The tumor signal consistency was mixed in four of five lesions and homogeneous in one. The tumor margins were well defined in all cases; in three cases the tumor margins were irregular, in one case smooth, and in the last case, one margin was irregular and the remaining margins were smooth. These findings are contrasted with the MR appearance of arachnoid cysts. Using identical imaging factors, four arachnoid cysts were studied and exhibited a homogeneous signal intensity that was identical to CSF on all pulse sequences; their margins were smooth and well defined in each case. These MR findings contribute to the characterization of extraaxial lesions.  相似文献   

20.

Purpose

To propose a new black‐blood (BB) pulse sequence that provides BB cine cardiac images with high blood‐myocardium contrast. The proposed technique is based on the conventional steady‐state free precession (SSFP) sequence.

Materials and Methods

Numerical simulations of the Bloch equation were conducted to compare the resulting signal‐to‐noise ratio (SNR) to that of conventional BB imaging, including the effects of changing the imaging flip angle and heart rates. Simulation results were verified using a gel phantom experiment and five normal volunteers were scanned using the proposed technique.

Results

The new sequence showed higher SNR and contrast‐to‐noise ratio (CNR) (≈100%) compared to the conventional BB imaging. Also, the borders of the left ventricle (LV) and right ventricle (RV) appear more distinguishable than the conventional SSFP. We were also able to cover about 80% of the cardiac cycle with short breath‐hold time (≈10 cardiac cycles) and with reasonable SNR and CNR.

Conclusion

Based on an SSFP conventional sequence, the new sequence provides BB cines that cover most of the cardiac cycle and with higher SNR and CNR than the conventional BB sequences. J. Magn. Reson. Imaging 2009;30:94–103. © 2009 Wiley‐Liss, Inc.  相似文献   