首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Purpose: Intra-arterial digital subtraction angiography (DSA) has been considered the gold standard examination in the follow-up of patients treated with Guglielmi detachable coils (GDCs). However, DSA is an invasive and expensive investigation and results in exposure to ionising radiation to both patient and operator. The aim of this study was to compare MR angiography (MRA) with DSA with regard to patency of the occlusion of aneurysms following GDC treatment.Material and Methods: We performed 75 MRA and DSA examinations on 51 patients treated with GDCs. The examinations were performed 3-36 months after embolisation and the interval between MRA and DSA was less than 1 week. Hard copies of both studies were interpreted retrospectively and independently for residual flow within the aneurysm, residual aneurysmal neck, and parent and branch vessel flow.Results: Patency status of parent and branch vessel flow was correctly identified with MRA in all patients except 1. The sensitivity of MRA in revealing residual flow within the aneurysm was 97%. The specificity in ruling out residual flow within the aneurysm was 91%.Conclusion: MRA may replace DSA in the long-term follow-up of coiled cerebral aneurysms. The initial follow-up examination should, however, include both modalities.  相似文献   

2.
BACKGROUND AND PURPOSEOur purpose was to evaluate the ability of transcranial color-coded Doppler sonography (TCCD) to 1) identify Guglielmi detachable coils (GDCs) within intracranial aneurysms, 2) show endovascular aneurysmal occlusion and patency of parent and branch arteries, 3) determine the flow velocities within parent arteries and major branches before and after treatment, and 4) assess persistence of aneurysmal occlusion.METHODSThe sonographic appearance of GDCs was established experimentally by TCCD (2 to 2.5 MHz), which was then performed in 40 patients with 43 aneurysms occluded by GDCs. The patency of parent arteries and major branches was assessed qualitatively and compared with the immediate posttherapeutic angiographic appearance in every patient. Flow velocities were selectively measured and compared before and after treatment in 21 parent arteries and 24 major branches. Follow-up TCCD studies performed in 26 patients were compared with angiographic (16 cases) and MR angiographic (10 cases) findings for signs of recanalization of the treated aneurysms.RESULTSThe GDCs were identified experimentally and in the patients as hyperechoic structures of the size and shape, and in the location of, the treated aneurysm in 41 of 43 cases. TCCD in accordance with angiography showed a lack of flow in 42 aneurysms and the presence of flow signal in one large aneurysm. Patency of the parent artery was shown in 40 aneurysms and in all branches. Follow-up TCCD showed the coils unchanged in 23 of 26 cases. In three large aneurysms, TCCD indicated recanalization and reappearance of a flow signal separate from the parent artery.CONCLUSIONTCCD is a reliable, noninvasive means to assess parent artery and major branch patency and to reveal a lack of hemodynamic compromise in the vicinity of aneurysms after endovascular therapy. On follow-up examinations, TCCD was able to detect signs of aneurysmal recanalization.  相似文献   

3.
BACKGROUND AND PURPOSE: Intravascular treatment of intracranial aneurysms is a relatively new therapeutic technique and long-term controlled angiographic trials are needed to assess persistence of aneurysm occlusion. Our purpose was to evaluate the effectiveness of 3D time-of-flight (3D-TOF) MR angiography as a noninvasive screening tool in the follow-up of cerebral aneurysms treated with Guglielmi detachable coils (GDCs). METHODS: Forty-nine patients with 50 intracranial aneurysms previously treated with GDCs were studied with both DSA and 3D-TOF MR angiography. In 14 cases, a second follow-up examination was performed, for a total of 64 aneurysms evaluated. In 25 aneurysms, both pre- and postcontrast MR angiographic studies were obtained. RESULTS: In seven of 64 aneurysms, the MR angiographic studies were considered to be unreliable owing to the presence of artifacts that obscured part of the parent artery and did not allow an accurate evaluation of the aneurysm neck. These seven aneurysms, however, all were shown to be completely occluded at digital subtraction angiography (DSA). In the remaining 57 aneurysms, DSA revealed complete occlusion in 39 and the presence of residual patency in 18, whereas MR angiography showed complete occlusion in 38 and residual patency in 19. Enhanced MR angiography proved to be useful in evaluating residual patency in large and giant aneurysms and in better depicting the distal branch arteries. CONCLUSION: Although artifacts related to the presence of coils are evident on a considerable number of imaging studies, our findings indicate that MR angiography is useful in the evaluation of residual patency of cerebral aneurysms treated with GDCs and may eventually prove valuable in the follow-up of those cases in which a good initial correlation with DSA was demonstrated.  相似文献   

4.
BACKGROUND AND PURPOSE: Intra-arterial contrast angiographies are generally used to confirm treatment results of endovascular neurointerventions such as aneurysm obliteration. We compared MR angiography with digital subtraction angiography (DSA) as a follow-up technique for the detection of aneurysmal remnant cavities and arterial patency in patients treated for intracranial aneurysms with Guglielmi detachable coils (GDCs). METHODS: In 20 consecutive patients, follow-up MR angiography and routine intra-arterial cerebral angiography were performed on the same day 1 to 7 months (mean, 4.5 months) after embolization with GDCs. MR angiographic data were postprocessed for subvolume maximum intensity projections centered on the region of the treated aneurysm. Hard copies of both imaging studies were interpreted independently in a blinded fashion to record and compare remnant cavities, location of residual flow, and adjacent arterial narrowing, using DSA as the standard of reference. The interpreters also established an occlusion grade for the treated aneurysms as evidenced on DSA images and evaluated MR angiograms for artifactual effects. RESULTS: Overall sensitivity and positive predictive value of MR angiography in revealing aneurysmal remnant cavities were both 90%. Specificity in ruling out a remnant cavity with MR angiography was 91%. One remnant cavity was missed by MR angiography, and in five patients, false adjacent arterial encroachments were reported. CONCLUSION: MR angiography may be useful in the long-term follow-up of successfully treated small and medium-sized aneurysms after concurrent primary verification of their occlusion with DSA.  相似文献   

5.
PURPOSE: The purpose of our study was to prospectively evaluate 3D time-of-flight (TOF) MR angiography (MRA) in the follow-up of 27 intracranial aneurysms treated with Guglielmi detachable coils (GDCs). METHOD: From February 1997 to June 1998, 26 patients with 27 aneurysms were included in this prospective study. Aneurysms were located in the anterior circulation in 23 cases and in the posterior circulation in 4 cases. All patients underwent 3D TOF MRA and digital subtraction angiography (DSA) in the same week within 4 months after aneurysmal treatment with GDCs. No clinical events occurred during the follow-up. We analyzed residual flow within the coil mass and within the aneurysmal neck and the patency of the parent and adjacent arteries on MRA and DSA. MRA analysis was based upon MIPPED and source images. DSA was our gold standard. RESULTS: In all cases, the quality of MRA was good enough to be informative. In aneurysmal analysis, the sensitivity, specificity, positive predictive value, and negative predictive value of MRA were, respectively, 80, 100, 100, and 96% to diagnose residual flow within the coil mass (one false-negative case) and 83, 100, 100, and 95.5% to diagnose residual flow within the aneurysmal neck (one false-negative case). In arterial analysis, sensitivity and positive predictive value of MRA were 89 and 100% to diagnose patency of the parent artery (three false-negative cases) and 83 and 100% to diagnose patency of adjacent arteries (seven false-negative cases). CONCLUSION: In the follow-up of intracranial aneurysms treated with GDCs, 3D TOF MRA could be used as a screening test to select patients that should undergo DSA and thus could improve patient follow-up in terms of risk-benefit.  相似文献   

6.
BACKGROUND AND PURPOSE: The long-term outcome of patients treated with Guglielmi detachable coils (GDCs) remains unknown and is being evaluated. We sought to assess the feasibility and utility of contrast-enhanced MR angiography in the follow-up of anterior communicating artery (AcomA) aneurysms treated with GDCs. METHODS: In a prospective study, 20 consecutive patients with AcomA aneurysms underwent digital subtraction angiography (DSA), time-of-flight MR angiography (TOF-MRA), and contrast-enhanced MR angiography (MRA) 12 months after treatment with GDCs. The aneurysmal sac measured less than 10 mm in 19 patients and 12 mm in one patient. Two observers who did not analyze the DSA images independently reviewed the MRA images. Aneurysms were classified according to the presence of a residual neck (ie, complete occlusion, small residual neck, large residual neck, or not assessable). DSA was used as the standard of reference. RESULTS: Images from all examinations were assessable. Venous enhancement was observed in five cases at contrast-enhanced MRA; this did not affect image interpretation. Interobserver agreement was good. A comparison of the techniques showed good agreement in the detection of a residual neck. Two cases of a small residual neck were not detected at TOF-MRA, and one case of complete occlusion was misclassified as a small residual neck at contrast-enhanced MRA. CONCLUSION: Our findings showed that contrast-enhanced MRA is a valuable method for the follow-up of aneurysms in the AcomA after their treatment with GDCs. Further studies with multiple aneurysm locations and larger groups are required to determine the exact role of this technique.  相似文献   

7.
Boulin A  Pierot L 《Radiology》2001,219(1):108-113
PURPOSE: To compare three-dimensional (3D) time-of-flight magnetic resonance (MR) angiography with digital subtraction angiography (DSA) in the follow-up of intracranial aneurysms treated with selective endovascular placement of detachable coils. MATERIALS AND METHODS: Sixty-eight consecutive patients with intracranial aneurysms were included in the prospective study. The goal was to evaluate 3D time-of-flight MR angiography versus DSA for the detection of a residual aneurysm neck or residual flow inside the coil mesh. RESULTS: Eighty-one MR angiographic and 83 DSA examinations were performed; 15 patients were examined with both modalities twice. MR angiography was not possible in two patients. In another patient, the quality of MR angiography was not sufficient to assess the treated aneurysm. In 72 of the remaining 80 MR angiographic and DSA examinations, there was good correlation between the two modalities. In 54 cases, neither image type showed remnants or recurrence, but in 18, both showed residual aneurysm. In eight cases, the MR angiographic and DSA results differed. In one of these cases, MR angiography depicted residual aneurysm but DSA depicted an arterial loop. In seven cases, a small (<3-mm) remnant was not detected at MR angiography. CONCLUSION: Because very small aneurysm remnants or recurrences probably are not clinically important, MR angiography is an option for following up intracranial aneurysms treated with detachable coils and may partly replace DSA.  相似文献   

8.
BACKGROUND AND PURPOSE: For intracranial aneurysms treated with Guglielmi detachable coils, long-term follow-up is mandatory because coil compaction may occur and aneurysms may recur. The purpose of this study was to establish a noninvasive technique to visualize residual flow in coiled aneurysms. METHODS: We designed a 3D time-of-flight (3D-TOF) MR angiography (MRA) technique targeted to depict coiled aneurysms that employed a very short TE (1.54-1.60 ms) and a high spatial resolution (0.3 x 0.3 x 0.3 mm3 with zero-filling) to diminish spin dephasing. To diminish spin saturation, image volume was carefully positioned so that the neck of the targeted aneurysm was within 2 cm of the inflow portion along the stream of blood. Fifty-one MRA images of 39 coiled aneurysms in 39 patients were compared with digital subtraction angiography (DSA) images. DSA and MRA findings were interpolated retrospectively for parent and branch arteries' patency, as well as residual flow in aneurysms. In the latest 11 MR studies, a dark-blood 3D turbo spin-echo sequence was added to MRA to negate the effect high-signal-intensity thrombus. RESULTS: MRA visualized all parent and branch arteries with DSA confirmation. MRA visualized residual flow more frequently (38 studies) than did DSA (25 studies). Residual flow space visualized with MRA was always similar to or larger than that with DSA. The dark-blood sequence completely suppressed intraluminal high signal intensity on MRA images and confirmed that the high signal intensity was not due to thrombus. CONCLUSION: TOF MRA targeted to depict coiled intracranial aneurysms is noninvasive and superior to DSA in visualization of residual flow and, hence, useful for follow-up of coiled aneurysms.  相似文献   

9.
BACKGROUND AND PURPOSE: Previous studies have depicted arterial and aneurysmal anatomy with three-dimensional time-of-flight (3D-TOF) MR angiography before and after treatment with Guglielmi detachable coils (GDCs) and with CT angiography before and after treatment with stents and stent-grafts. We investigated the ability of time-resolved contrast-enhanced 3D MR angiography (3D MR digital subtraction angiography [DSA]) to accurately depict the anatomy of experimental lateral aneurysms before and after treatment with GDCs and a variety of stents or stent-grafts, and compared these findings with 3D-TOF MR angiography without and with contrast enhancement and CT angiography. METHODS: Two nitinol stents, two nitinol-polytetrafluoroethylene (PTFE) stent-grafts, and two stainless steel stents were deployed in three dogs with experimental carotid aneurysms. In a fourth animal, one of three aneurysms was completely occluded with GDCs. The other two aneurysms were loosely packed to ensure persistence of some residual aneurysmal lumen. Cut-film angiography, CT angiography, 3D-TOF MR angiography without and with contrast enhancement, and 3D MR DSA were performed in all dogs before and 3 weeks after treatment. RESULTS: 3D MR DSA was superior to conventional 3D-TOF MR angiography without and with contrast enhancement in accurately depicting experimental lateral aneurysms and superior to CT angiography in depicting aneurysms treated by GDCs. 3D MR DSA and CT angiography were comparable in depicting vessels treated with nitinol stents and stent-grafts, whereas CT angiography was superior for showing vessels treated by stainless steel stents. CONCLUSION: We recommend further development and clinical evaluation of 3D MR DSA for imaging cerebral aneurysms before and after treatment with GDCs. 3D MR DSA or CT angiography may be useful for evaluating vessels containing nitinol stents or nitinol-PTFE stent-grafts, whereas CT angiography should be used for follow-up of vessels treated by stainless steel stents.  相似文献   

10.
目的:评价磁共振血管成像(MRA)在随访43例病人的45个颅内动脉瘤GDC栓塞后的价值。材料和方法:以数字减影血管造影(DSA)作为诊断的金标准,回顾研究43例病人的45个颅内动脉瘤(前循环34个,后循环11个)MRA检查。所有的病人在GDC栓塞治疗后9个月之内的同一周行DSA和MRA检查,这期间不作处理。分析弹簧圈内残余血流、载瘤动脉和邻近动脉血流,MRA以最大强度投影(MIP)重建和源图像为基础。结果:所有病例中,MRA能提供良好的信息。对于动脉瘤的分析,MRA的敏感性、特征性、阳性预测价值、阴性预测价值,诊断弹簧圈内残余血流分别为87.5%、100%、100%、97%,诊断瘤颈的残余血流分别为90%、100%、100%、97%。对于动脉通畅性分析,MRA的敏感性和阴性预测价值,载瘤动脉分别是90.5%和100%,邻近动脉分别是85.7%和100%。结论:在随访GDC栓塞的动脉瘤中,MRA可以作为一个筛选手段,提高检查效率,减少病人的随访风险。  相似文献   

11.
BACKGROUND AND PURPOSE: Three-dimensional time-of-flight (TOF) MR angiography has been evaluated in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils (GDCs) with good results. Some of the studies used contrast material in addition to the 3D TOF MR technique and others did not. We assessed the usefulness of contrast material with 3D TOF MR angiography by comparing this sequence before and after contrast material injection. METHODS: Fifty-eight patients harboring a total of 71 cerebral aneurysms previously treated with GDCs were included in the prospective study. MR angiography (at 1.5 T) was performed with a 3D TOF sequence before and after injection of gadolinium-based contrast material. Features evaluated were presence and size of a neck remnant, parent and adjacent vessel patency, and venous overlap. Digital subtraction angiography was the standard of reference. RESULTS: Comparison of the techniques showed a good agreement in the detection of residual flow. Six cases of small residual neck were not detected with either the 3D TOF or the contrast-enhanced 3D TOF sequence. In one case of giant aneurysm, the extent of recanalization was more evident after contrast material administration. The use of contrast material did not help to show the parent and adjacent arteries. Venous overlap on contrast-enhanced 3D TOF angiograms did not affect image interpretation. CONCLUSION: In this series, the use of intravenous contrast material did not improve the ability of 3D TOF MR angiography to depict the presence of residual or recurrent aneurysms previously treated with endovascular coiling. In one giant aneurysm, use of intravenous contrast material did result in improved visualization of a residual aneurysm.  相似文献   

12.
BACKGROUND AND PURPOSE: 3D time-of-flight MR angiography (3D TOF MRA) may be used as noninvasive alternative to digital subtraction angiography (DSA) for the follow-up of patients with intracranial aneurysms treated with Guglielmi detachable coils (GDCs). We aimed to determine the influence of aneurysm size and location on diagnostic accuracy of 3D TOF MRA for follow-up of intracranial aneurysms treated with GDCs. MATERIALS AND METHODS: Two hundred and one 3D TOF MRAs in 127 consecutive patients with 136 aneurysms were compared with DSA as standard of reference. Sensitivity and specificity of 3D TOF MRA for detection of residual or reperfusion of the aneurysms was calculated with regard to aneurysm size and location. RESULTS: Overall sensitivity and specificity of MRA was 88.5% and 92.9%, respectively. Sensitivity was lower for aneurysms 相似文献   

13.
BACKGROUND AND PURPOSEComplete intracranial aneurysmal occlusion by endovascular techniques is required for successful treatment and is presumably influenced by several parameters. The purpose of this study was to investigate whether operator experience and angiographic characteristics of intracranial aneurysms correspond to the degree of endovascular occlusion in the period immediately after treatment with Guglielmi detachable coils (GDCs).METHODSPre- and posttreatment angiograms of 72 patients undergoing GDC treatment were reviewed retrospectively. The following angiographic characteristics of the aneurysms were evaluated: largest diameter of the sac, volume, neck size, shape, type, cerebrovascular site, surroundings, and likely direction of aneurysmal inflow as judged by a score developed by measuring aneurysm/parent artery angulation. The chronological sequence in which the aneurysms were treated was used as a measure of operator experience. A chi2-test was used to identify parameters that correlated with outcomes of total (100%) or partial (<100%) occlusion. A multivariate analysis was used to determine the factors most predictive of aneurysmal occlusion at therapy.RESULTSParameters that correlated with the unsatisfactory result of partial occlusion were large aneurysmal diameter, volume, and neck size, more direct inflow (ie, increasingly obtuse aneurysm/parent artery angulation), and early chronological presentation in the series. The three factors most predictive of partial occlusion were large aneurysmal diameter, more direct inflow, and early chronological order of treatment.CONCLUSIONSeveral morphologic features of aneurysms were identified to help predict the immediate outcome of occlusion with GDCs. This study underscores the existence of a steep learning curve associated with GDC use in treating aneurysms and the importance of operator experience in achieving optimal therapeutic results.  相似文献   

14.
BACKGROUND AND PURPOSE: This study was undertaken to assess the utility of contrast-enhanced MR angiography at 6 months after endovascular treatment of intracranial aneurysms with Guglielmi detachable coils. METHODS: Contrast-enhanced MR angiography was performed in 47 patients at 6 and 12 months after endovascular treatment of intracranial aneurysms (48 aneurysms). Digital subtraction angiography (DSA) was used as reference and was performed at 12 months after the treatment in all patients. MR angiographs were analyzed independently by two senior radiologists. DSA and MR angiography findings were assigned into one of three categories: complete obliteration, residual neck, or residual aneurysm. RESULTS: All examinations were assessable. Interobserver agreement was judged as very good for contrast-enhanced MR angiography (kappa=0.96), with one discrepancy between examiners. Comparison between MR angiography at 6 months and DSA at 12 months showed an excellent agreement between techniques (kappa=0.93). Two cases of complete occlusion at DSA were misclassified as a residual neck at 6-month MR angiography. All aneurysm recanalizations at DSA already were detected on MR angiography at 6 months. The size of aneurysm recanalization did not increase between both MR angiographs performed at 6 and 12 months. CONCLUSION: Contrast-enhanced MR angiography after selective embolization of intracranial aneurysm seems to predict properly early aneurysm recanalizations.  相似文献   

15.
PURPOSETo describe the characteristic CT, MR, and angiographic features of giant serpentine aneurysms and discuss their endovascular treatment.METHODSThirteen patients with giant serpentine aneurysms were studied at our institution in the last 3 years. They all underwent CT and MR studies as well as cerebral angiography. More recently, some of the patients were studied with MR angiography. Seven patients had endovascular occlusion of the giant serpentine aneurysms, 3 with N-butyl cyanoacrylate, 2 with Guglielmi detachable coils, and 2 with detachable balloons.RESULTSGiant serpentine aneurysms mimic cerebral neoplasms on CT and MR studies; they are often associated with mass effect and adjacent edema, and they enhance with contrast medium. The cerebral angiogram shows a residual irregular lumen of the partially clotted aneurysm, which continues into normal branches supplying the distal arterial territory. Six patients were treated successfully with an endovascular approach consisting of complete and permanent occlusion of the parent artery.CONCLUSIONGiant serpentine aneurysms from a subgroup of large intracranial aneurysms that have specific CT, MR, and angiographic features, which should be recognized before their treatment. The endovascular treatment of the aneurysm consists of permanent occlusion of the parent artery.  相似文献   

16.
The sensitivities and specificities of three-dimensional time-of-flight MR angiography (3D-TOF MRA) and 3D digital subtraction angiography (3D-DSA) were compared for evaluation of cerebral aneurysms after endosaccular packing with Guglielmi detachable coils (GDCs). Thirty-three patients with 33 aneurysms were included in this prospective study. 3D-TOF MRA and 3D-DSA were performed in the same week on all patients. Maximal intensity projection (MIP) and 3D reconstructed MRA images were compared with 3D-DSA images. The diameters of residual/recurrent aneurysms detected on 3D-DSA were calculated on a workstation. In 3 (9%) of 33 aneurysms, 3D-TOF MRA did not provide reliable information due to significant susceptibility artifacts on MRA. The sensitivity and specificity rates of MRA were 72.7 and 90.9%, respectively, for the diagnosis of residual/recurrent aneurysm. The diameters of residual/recurrent aneurysms that could not be detected by MRA were significantly smaller than those of detected aneurysms (mean 1.1 vs mean 2.3 mm). In one aneurysm of the anterior communicating artery (ACoA), the relationship between the residual aneurysm and the ACoA was more evident on MRA than DSA images. MRA can detect the recurrent/residual lumen of aneurysms treated with GDCs of up to at least 1.8 mm in diameter. 3D-TOF MRA is useful for follow-up of intracranial aneurysms treated with GDCs, and could partly replace DSA.  相似文献   

17.
BACKGROUND AND PURPOSE: The objective was to evaluate the results of high-resolution, fast-speed, section-interpolation MR angiography and digital subtraction angiography (DSA), thereby examining the potential use of a primary noninvasive screening test for intracranial aneurysms. METHODS: The images were obtained in 39 cerebral aneurysmal lesions from 30 patients with a time-of-flight MR angiographic technique using a 1.5-T superconducting MR system. The total image volume was divided into four slabs, with 48 partitions each. To save time, only 24 phase-encoded steps were measured and interpolated to 48. The parameters used included 30/6.4 (TR/TE), a flip angle of 25 degrees , a 160x512 matrix, a field of view of 150x200, 7 minutes 42 seconds of scan time, an effective thickness of 0.7 mm, and an entire thickness of 102.2 mm. Maximum intensity projection was used for the image analysis, and a multiplanar reconstruction technique was used for patients with intracranial aneurysms. RESULTS: Among 39 intracranial aneurysmal lesions in 30 patients, 21 were ruptured and 18 were unruptured. Twelve lesions were less than 2 mm in size, 12 were 3 to 5 mm, 12 were 6 to 9 mm, and three were larger than 10 mm. At initial examinations, 38 of 39 aneurysmal lesions were detected by both MR angiography and DSA, with 97% sensitivity. In confirming aneurysms in neck and parent vessels, multiplanar reconstruction was successful in detecting all 39 aneurysms, whereas MR angiography was successful in detecting 27 (69%) and DSA was successful in detecting 32 (82%) of the lesions. CONCLUSION: High-resolution MR angiography with a section-interpolation technique showed equal results to those of DSA for the detection of intracranial aneurysms and may be used as a primary noninvasive screening test. In the evaluation of aneurysms in neck and parent vessels, the concurrent use of MR angiography and multiplanar reconstruction was far superior to the use of either MR angiography or DSA alone.  相似文献   

18.
The purpose of this study was to assess the feasibility of high spatial resolution, selective arterial phase, 3D contrast-enhanced (CE) MR angiography with first pass bolus, software-trigger, elliptical centric view ordering in the detection of intracranial aneurysms. Our study included nine consecutive patients with ten intracranial aneurysms. 3D TOF MR angiography and 3D CE MR angiography were carried out with a 1.5-T MR scanner. 3D CE MR angiography was performed with an automated bolus detection algorithm and elliptical centric view order using ultrafast SPGR with a spatial resolution of 0.63×0.83×0.5 mm and imaging time of 55 s. Observers detected seven of ten aneurysms on 3D TOF MR angiograms and nine of ten aneurysms on 3D CE MR angiograms. 3D CE MR angiography clearly revealed an IC-PC aneurysm with a relatively smaller neck, a broad-based small aneurysm originating from tortuous and dilated MCA bifurcation, and a residual aneurysm and parent vessels adjacent to metallic aneurysmal clips, which had relatively low signal intensities on 3D TOF MR angiograms. 3D CE MR angiography was found to be a good and promising technique for detecting intracranial aneurysms with small necks and slow flow, vasculature with aneurysmal clips and tortuous vasculature with disturbed flow.  相似文献   

19.
We evaluated a time-of-flight three-dimensional MR angiographic sequence with an ultrashort echo time for its ability to characterize the perfusional state of cerebral aneurysms that had been treated with Guglielmi detachable coils and to depict adjacent cerebral arteries. The results were compared with findings at conventional MR angiography and digital subtraction angiography. Adjacent vessels were seen better in 36% of patients imaged with the new technique. Both MR angiographic methods detected residual cerebral aneurysmal perfusion with a tendency to overestimate the patent portion of the aneurysm.  相似文献   

20.
BACKGROUND AND PURPOSE: Digital subtraction angiography (DSA) is used to follow-up intracranial aneurysms treated with detachable coils to identify recurrence and determine need for additional treatment. However, DSA is invasive and involves a small risk of neurologic complications. We assessed the feasibility and usefulness of 3D time-of-flight (TOF) MR angiography (MRA) performed at 3T compared with DSA for the follow-up of coil-treated intracranial aneurysms. METHODS: In a prospective study, 20 consecutive patients with 21 intracranial aneurysms treated with coils underwent DSA and nonenhanced and enhanced multiple overlapping thin-slab acquisition 3D TOF MRA at 3T on the same day at a mean follow-up of 6 months (range, 4-14 months) after coil placement. MRA images were evaluated for presence of artifacts, presence and size of aneurysm remnants and recurrences, patency of parent and branch vessels, and added value of contrast material enhancement. MRA and DSA findings were compared. RESULTS: Interobserver agreement of MRA was good, as was agreement between MRA and DSA. All three recurrences that needed additional treatment were detected with MRA. Minor disagreement occurred in four cases: three coil-treated aneurysms were scored on MRA images as having a small remnant, whereas on DSA images these aneurysms were occluded; the other aneurysm was scored on MRA images as having a small remnant, whereas on DSA images this was a small recurrence. Use of contrast material had no additional value. Coil-related MR imaging artifacts were minimal and did not interfere with evaluation of the occlusion status of the aneurysm. CONCLUSION: High-spatial-resolution 3D TOF MRA at 3T is feasible and useful in the follow-up of patients with intracranial aneurysms treated with coil placement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号