首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BACKGROUND: We report a multiinstitutional study on intermediate-term outcome of intravascular stenting for treatment of coarctation of the aorta using integrated arch imaging (IAI) techniques. METHODS AND RESULTS: Medical records of 578 patients from 17 institutions were reviewed. A total of 588 procedures were performed between May 1989 and Aug 2005. About 27% (160/588) procedures were followed up by further IAI of their aorta (MRI/CT/repeat cardiac catheterization) after initial stent procedures. Abnormal imaging studies included: the presence of dissection or aneurysm formation, stent fracture, or the presence of reobstruction within the stent (instent restenosis or significant intimal build-up within the stent). Forty-one abnormal imaging studies were reported in the intermediate follow-up at median 12 months (0.5-92 months). Smaller postintervention of the aorta (CoA) diameter and an increased persistent systolic pressure gradient were associated with encountering abnormal follow-up imaging studies. Aortic wall abnormalities included dissections (n = 5) and aneurysm (n = 13). The risk of encountering aortic wall abnormalities increased with larger percent increase in CoA diameter poststent implant, increasing balloon/coarc ratio, and performing prestent angioplasty. Stent restenosis was observed in 5/6 parts encountering stent fracture and neointimal buildup (n = 16). Small CoA diameter poststent implant and increased poststent residual pressure gradient increased the likelihood of encountering instent restenosis at intermediate follow-up. CONCLUSIONS: Abnormalities were observed at intermediate follow-up following IS placement for treatment of native and recurrent coarctation of the aorta. Not exceeding a balloon:coarctation ratio of 3.5 and avoidance of prestent angioplasty decreased the likelihood of encountering an abnormal follow-up imaging study in patients undergoing intravascular stent placement for the treatment of coarctation of the aorta. We recommend IAI for all patients undergoing IS placement for treatment of CoA.  相似文献   

2.
Although balloon-expandable stent implantation for native aortic coarctation is a preferred method in the adolescent age group, there are insufficient data about indications for and the efficacy of the procedure in a younger age group. The aim of this study was to compare and evaluate the data of young pediatric and adolescent patients who underwent balloon-expandable stent implantation because of native aortic coarctation. The retrospective analysis included the demographic characteristics and data related to the procedure and follow-up of patients who underwent stent implantation for native aortic coarctation between August 2010 and November 2017. Patients with re-coarctation were excluded from the study. The patients were separated into 2 groups as the adolescent group (Group I: 10–18 years) and the pediatric group (Group II: ≤ 9.9 years). Group-I comprised of 18 patients and Group-II, 32 patients. Covered stent was implanted to 32 (73%) patients and uncovered stent to 12 (27%) patients. The procedural success rate was 100%. Following stent implantation, peak systolic gradient decreased significantly in both groups (P < .0001) (Group-I: from 35.9 ± 16.6 mm Hg–2.2 ± 3.4 mm Hg, Group II: from 34 ± 13.3 mm Hg–3 ± 4.09 mm Hg). Complications developed in 3 patients, and all in Group I. Femoral hematoma developed in 1 patient, balloon rupture occurred during the procedure in 1 patient, and there was temporary loss of pulse in 1 patient. All the complications were treated successfully. All the patients were taking anti-hypertensive drugs before intervention and during the mean 23-month follow-up period (range, 2–84 months), hypertension recovered in 35 (80%) patients and drugs were terminated. Stent implantation for aortic coarctation in the pediatric age group may provide pleasing results, reducing the coarctation gradient, providing effective dilatation in the lesion area and eliminating hypertension.  相似文献   

3.
A 19-year-old girl with coarctation of the aorta and patent ductus arteriosus underwent simultaneous treatment of native coarctation and closure of ductus arteriosus using a covered Cheatham-Platinum stent. This technique may be used as an alternative to other forms of interventional therapy or surgery for this combination of lesions in adolescents and adults.  相似文献   

4.
AIMS: Since the late 1980s, endovascular stents have been used in the treatment of several vascular lesions. In the last decades, stent implantation has been proposed as a reliable option for the treatment of coarctation of the aorta. In this setting, it seems to have some advantages, rendering it superior to angioplasty alone. METHODS AND RESULTS: Between December 1997 and December 2004, 71 consecutive patients (44 males and 27 females) underwent cardiac catheterization for native or recurrent coarctation of the aorta. Seventy-four stents were implanted. All discharged patients were enrolled in a follow-up programme. Every patient underwent clinical evaluation, echo-colour Doppler studies, and exercise ECG at 1 and 6 months after the stent implantation. Peak systolic gradient dropped from 39.3 +/- 15.3 to 3.6 +/- 5.5 mmHg (P = 0.0041). The diameter of the coarcted segment increased from 8.3 +/- 2.9 to 16.4 +/- 3.8 mm (P = 0.037). In our series, one death occurred in a 22-year-old girl with a recurrent coarctation of the aorta, just after stent implantation. The rate of minor complications was <2%. Re-dilatation of a previously implanted stent was performed in three patients. CONCLUSION: In our experience (the largest reported to the best of our knowledge), stenting of a coarctation/re-coarctation of the aorta represents a safe alternative treatment without a significant mid-long-term complication.  相似文献   

5.
We report the immediate results and the short-term follow-up in a group of selected patients with coarctation of the aorta who underwent endovascular stent implantation. Balloon-expandable stents were implanted in 6 patients (mean age 19.8 ± 5.1 years) with coarctation of the aorta (4 recurrent and 2 native) who underwent a total of 7 procedures (6 implantation and 1 further expansion). The systolic peak pressure gradient was decreased from 36.7 ± 16.9 to 13.3 ± 23.2 mm Hg (P < 0.005). There was a 66% increase in the mean coarctation diameter from 9.3 ± 1.7 to 15.6 ± 3.1 mm (P = 0.001) with the ratio of the coarctation to descending aorta diameter, measured at the level of the diaphragm, increasing from 0.49 ± 0.1 to 0.81 ± 0.2 (P < 0.005). The dilatation was successful in expanding the stent to an acceptable diameter in 5 of 6 patients. One patient underwent successful further expansion of a stent implanted 22 months previously. There were no immediate complications during balloon expansion and stent implantation. One patient suffered a femoral arterial bleed requiring surgical repair. There was one unrelated death. All patients were hypertensive (systolic blood pressure >140 mm Hg) prior to stent implantation. At mean follow-up of 8 months, 3 patients are normotensive. There was no recurrence of coarctation, aortic dissection, or aneurysm formation in the patients in whom stent implantation was successful. These findings indicate that balloon-expandable stent implantation for coarctation of the aorta in selected patients is a safe and effective alternative approach for relieving the obstruction with a low complication rate and no recoarctation at short-term follow-up. © 1996 Wiley-Liss, Inc.  相似文献   

6.
7.
Background: To evaluate the mid and long‐term prognosis after stenting of native or recurrent CoA, we studied the cardiovascular parameters in the follow‐up period up to 13 years. Methods and results: Between 1993 and 2006, 68 patients underwent stent implantation for aortic coarctation (average age 25.5 years, range 5.7–65 years, average weight 65.5 kg, range 32–122 kg). Forty‐six (68%) patients were aged >17 years. Stenting was performed for native coarctation in 41 and for recurrent coarctation in 27 patients, in 23 (34%) patients with a covered stent. Redilation was carried out in 26 (38%) patients. The invasive systolic gradient decreased from mean (±SD) 25 (±15) mm Hg to 5 (±5) mm Hg (P < 0.0005). The descending aorta pressure increased from 80 (±15) mm Hg to 101 (±18) mm Hg. The systolic right arm blood pressure decreased from a mean of 153 (±24) mm Hg to 129 (±18) mm Hg (P < 0.0005). Complications like small dissections were rare. Follow‐up (6 days to 13 years, mean 41 months) was available in 66 patients, in 23 after reintervention at a mean of 71 months, range of 8 months to 10.3 years. Fifty‐one percent remained clinically hypertensive. Conclusions: Stenting of aortic coarctation gives good medium‐term results. Frequent reintervention relate to deliberately under‐dilating stents during the initial procedure. The reintervention rate has reduced since the introduction of covered stents. © 2011 Wiley‐Liss, Inc.  相似文献   

8.
We report a case of an infant with an extensive hemangioma encompassing the thoracic aorta, associated with complex coarctation. Surgical approach was abandoned for fear of bleeding. The complexity of the coarctation made it unsuitable for balloon dilation. We implanted a stent with significant angiographic improvement and resolution of systemic hypertension.  相似文献   

9.
BACKGROUND: Little is known regarding the long-term follow-up results of balloon angioplasty (BA) for patients with native aortic coarctation (AC) on left ventricular hypertrophy (LVH) regression. OBJECTIVES: The purpose of this study was to define the long-term effect of BA of AC on LVH in adolescent and adult patients. METHODS: Follow-up data of 53 patients (36 male) mean age 24 +/- 9 years undergoing BA for discrete AC at median interval of 11.8 years (range 4-18 years) including cardiac catheterization, magnetic resonance imaging, and Echocardiography form the basis of this study. Patients were divided into two groups at 1 year after BA based on absence (group A) or presence (group B) of persistent hypertension and need for medication. RESULTS: Forty-nine patients had baseline LVH, BA produced an immediate reduction in peak AC gradient from 66 +/- 23 mm Hg (95% confidence interval [CI]: 59.5-72.7) to 10.8 +/- 7 mm Hg (95% CI: 8.8-12.5) (P < 0.0001). Follow-up catheterization 12 months later revealed a residual gradient of 6.2 +/- 6 mm Hg (95% CI: 4.4-7.9) (P < 0.001). The blood pressure had normalized without medication in 38 of the 49 patients (165 +/- 17 to 115 +/- 10 mm Hg). Left ventricular mass index (LVMI) decreased significantly (>20% decrease LVMI from baseline) in 48 patients (98%) at median interval 1.4 years (range 0.5-3 years) post BA, group A (38 patients) LVMI decreased from 132 +/- 30.7 g/m(2) (95% CI: 122-141.9) to 86 +/- 19.9 g/m(2) (95% CI: 79.5-92.5) (P < 0.0001). Similarly, in 10 patients (group B) the LVMI decreased from 157 +/- 38.7 g/m(2) (95% CI: 127-185) to 102 +/- 29 g/m(2) (95% CI: 105-151) (P < 0.0001) at follow-up. Mild (<20% decrease in LVMI) regressions were noted in one patient from group B. There was no progression to LVH in the four patients who had normal baseline LVMI. CONCLUSION: (1) Long-term results of BA for discrete AC are excellent and should be considered as first option for treatment of this disease; (2) Regression of LVH (> or =20% reduction in LVMI) occurred in 98% of patients after BA.  相似文献   

10.
We, herein, report the first use of a Magmaris® magnesium‐based vascular scaffold for native aortic coarctation in a 1,980 g infant with multiple malformations. Due to the low body weight, complex illness, and clinical instability, it was decided to delay surgical correction. After insufficient results had been obtained by balloon angioplasty, Magmaris® implantation was chosen to bridge the patient to surgery by stabilizing left ventricular function and to allow for sufficient growth. Due to significant early stent restenosis and complete loss of radial force, the patient required balloon reangioplasty only 21 days after Magmaris® implantation and early surgical correction. In addition, high systemic sirolimus levels were detected 48 hr after the intervention (5 ng/mL). Although the bioresorbable scaffold was successfully used as a short‐term bridge‐to‐surgery in our case, due to significant early stent failure (loss of radial force), this approach does not seem promising for long‐term bridging of infants with aortic coarctation. In addition, the consequences of sirolimus‐induced systemic immunosuppression may further limit the applicability of Magmaris® scaffolds in infants with congenital heart disease.  相似文献   

11.
This case demonstrates a novel use of stent implantation for relief of coarctation of the aorta caused by protrusion of a Rashkind patent ductus arteriosus umbrella. Follow-up 3 years after stent implantation shows complete relief of obstruction.  相似文献   

12.
Data regarding stent implantation for stenotic aortoarteriopathy (SAA) are incomplete. We report on nine patients with this rare syndrome who underwent arterial stent implantation. Indications, results, and complications for patients with SAA were reviewed. Nine patients underwent 11 procedures. Twenty-two stents were implanted in the aorta or brachiocephalic vessels. Five patients had diffuse stenoses, three patients had middle aortic syndrome, and one patient had thoracic and abdominal coarctation. Associated diagnoses included Williams syndrome (2), neurofibromatosis (2), Takayasu's (1), and congenital rubella (1). Median gradient was 60 mm Hg (20-140 mm Hg). Poststent gradient was 15 mm Hg (0-60 mm Hg; P < 0.001). Additional stents were implanted in two patients and five underwent stent redilation. Two patients (22%) were found to have aneurysm formation. Stent implantation effectively provides gradient relief in SAA. Gradient reduction persists or is amenable to redilation. Importantly, however, uncomplicated stent implantation does not preclude aneurysm formation and may be more common than in traditional patient groups.  相似文献   

13.
We report on a 13-year-old girl with coarctation of the aorta and patent ductus arteriosus who underwent successful simultaneous stent implantation for the coarctation and catheter closure of the ductus using an Amplatzer duct occluder. Cathet. Cardiovasc. Intervent. 47:36–38, 1999. © 1999 Wiley-Liss, Inc.  相似文献   

14.
An 11-year-old male with a severe abdominal aortic coarctation, presumably secondary to aortitis, underwent successful percutaneous balloon dilation that resulted in near-complete relief of the obstruction. Intravascular ultrasound imaging showed a major endovascular tear immediately following dilation and satisfactorily excluded significant branch (superior mesenteric) artery compromise. Arterial remodelling was demonstrated with persistence of the gradient relief over a 12-month follow-up period. © 1996 Wiley-Liss, Inc.  相似文献   

15.
BACKGROUND: Little is known regarding the long-term follow-up results of balloon angioplasty (BA) for patients with aortic coarctation (AC) on systemic hypertension. HYPOTHESIS: To define the long-term effect of BA of AC on systemic hypertension in adolescent and adult patients. METHODS: Follow-up data of 53 patients (36 male), mean age 24 +/- 9 years, undergoing BA for discrete AC at median interval of 11.8 years (range, 4-18 years), including cardiac catheterization, magnetic resonance imaging (MRI), and echocardiography. Patients were divided into two groups at 1 year after BA on the basis of absence (group A: 40 patients) or presence (group B: 11 patients) of persistent hypertension and need for medication. RESULTS: Fifty-one patients had baseline hypertension, BA produced an immediate reduction in peak AC gradient from 66 +/- 23 mmHg to 10.8 +/- 7 mmHg (p < 0.0001). The immediate systolic blood pressure (SBP) decreased from 165 +/- 17 mmHg (95% CI: 159 to 171) to 125 +/- 10 mmHg (95% CI: 122 to 131) (p < 0.001) in 40 patients (group A) and from 184 +/- 19 mmHg (95% CI: 169 to 198) to 142 +/- 22 mmHg (95% CI: 124 to 156) (p<0.001) in 11 patients (group B). At 1-year follow-up, SBP decreased further to 115 +/- 10 in group A (95% CI 111-119) and 134 +/- 19 in group B (95% CI 122-142) (p<0.001). The blood pressure had normalized without medication in group A (165 +/- 17 to 115 +/- 10 mmHg). CONCLUSION: Long-term results of BA for discrete AC are excellent and should be considered as the first option for treatment of this disease. No paradoxical hypertension occurred post angioplasty, and normalization of blood pressure without medication occurred in 78% of the patients after BA.  相似文献   

16.
BACKGROUND: The impact of vascular remodeling pattern on intimal hyperplasia (IH) after coronary stenting is unknown. HYPOTHESIS: The preintervention remodeling pattern of the lesion might be associated with IH after the coronary stenting procedure. METHODS: Serial (pre-, post-stent implantation, and follow-up) intravascular ultrasound (IVUS) images were obtained in 58 patients with single-stent implantation (GFX stents in 41 and NIR in 17). The matching IVUS image slices at the preintervention lesion site were selected for serial comparisons. The remodeling index (RI) was defined as lesion/proximal reference external elastic membrane cross-sectional area (CSA) at preintervention lesion site. Adequate remodeling was defined as a RI > 0.95 and inadequate remodeling as a RI < or = 0.95. Vessel stretching, percent vessel stretching, and percent IH CSA, as well as pre- and postintervention IVUS variables were evaluated according to the remodeling pattern. RESULTS: The percent IH CSA was 31% in adequate remodeling (n = 29, mean RI = 1.05) and 41% in inadequate remodeling (n = 29, mean RI = 0.88) (p = 0.049). Percent vessel stretching was 15% in adequate remodeling and 22% in inadequate remodeling (p = 0.007). The RI inversely correlated with percent vessel stretching (r = -0.435, p = 0.001). CONCLUSIONS: Compared with preintervention adequate remodeling, inadequate remodeling was associated with increased percent IH CSA, which might be related with more vessel stretching.  相似文献   

17.
A female infant developed severe aortic coarctation 42 days after a Norwood operation. Balloon dilatation was ineffective due to rapid recoil of the narrowing, but stent implantation completely abolished coarctation. Although the patient died because of low systemic output with high pulmonary flow 62 days after stent implantation, an autopsy showed that the implanted stent was widely patent without any restenosis. Transcatheter stent implantation should be considered for coarctation in selected situations even in early infancy.  相似文献   

18.
During a thirteen years period 29 patients 80 years of age and older, underwent surgical procedure for abdominal aortic aneurysm. There were 9 elective aortic reconstructions and 20 ruptured abdominal aortic aneurysms (AAA) repairs. Perioperative mortality after elective AAA resection was 33% vs 50% after ruptured AAA (a postoperative period of 30 days was considered). Comparison of survival following aortic reconstruction in 14 patients with survival of general population matched for age, sex and race, is not significant.  相似文献   

19.
A 5‐day‐old neonate presented in shock, with signs and symptoms of severe coarctation of the aorta. He was diagnosed with a patent aortic arch, and a completely thrombosed abdominal aorta. The authors report the successful transcatheter removal of the entire thrombus using the AngioJet® Thrombectomy system. This represents the first published use of the AngioJet® catheter in the aorta of a pediatric patient. © 2012 Wiley Periodicals, Inc.  相似文献   

20.
We report the case of a 23-year-old man with coarctation of the aorta whose baroreceptor sensitivity was extremely reduced. Antihypertensive therapy was effectively performed after coarctectomy. Only one month after coarctectomy, baroreflex sensitivity had recovered. The present case is believed to be the first in which reduced baroreceptor sensitivity in coarctation of the aorta was reversible in the early phase after coarctectomy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏