首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
The objective of this study was to demonstrate the appearance of ampullary carcinoma using current MR techniques, including fat suppression, gadolinium enhancement, and MR cholangiography. Nine patients with ampullary carcinoma were examined by MRI at 1.5 T. MR examinations included T1-weighted spoiled gradient echo, T1-weighted fat-suppressed, and immediate postgadolinium spoiled gradient echo images for all patients and MR cholangiography for three patients. The imaging features of ampullary carcinomas, including tumor size and morphology, signal intensity, and enhancement characteristics, were determined. Ampullary carcinomas shown on MR images ranged in size from 1.5 to 5.5 cm. Tumors were low in signal intensity on precontrast T1-weighted spoiled gradient echo and T1-weighted fat-suppressed images relative to normal pancreatic tissue and enhanced less than normal pancreas on immediate postgadolinium spoiled gradient echo images. Tumor conspicuity was greatest on immediate postgadolinium spoiled gradient echo images. MR cholangiography demonstrated high grade obstruction of the common bile duct and mild dilatation of the pancreatic duct at the level of the ampulla with abrupt termination of the ducts in two untreated patients and moderate dilatation of the common bile duct in one patient who had a biliary stent. Ampullary carcinomas can be demonstrated on MR images as small masses arising at the ampulla. Tumors are well defined on immediate postgadolinium spoiled gradient echo images.  相似文献   

2.
The aim of this study was to describe the magnetic resonance (MR) appearances of diseases of the stomach using combined T1-weighted spoiled gradient-echo, T2-weighted single-shot echo train spin-echo and gadolinium-enhanced spoiled gradient-echo sequences. All patients with gastric diseases who underwent combined T2-weighted single-shot echo train spin-echo and gadolinium-enhanced conventional and fat-suppressed spoiled gradient-echo imaging between October 1, 1996 and March 1, 1999, and who had histological or other imaging proof of disease, were included in this study. This patient population was comprised of 40 patients with subsequently proven gastric abnormalities, including malignant tumors (25) or benign disease (15). The MRI sequences included T1-weighted, T2-weighted, and early and late gadolinium-enhanced spoiled gradient-echo (SGE) images. Evaluation was made of the following parameters: a) the ability to detect the disease process on MRI, by comparing the original prospective MR reports with the records of the pathology department; b) the MR appearance of a variety of gastric diseases; and c) the sequences that most clearly demonstrated abnormalities by retrospective review of the MR studies. MR images demonstrated 22 of 25 malignant tumors. Evaluation of the extent of the tumor was correctly shown in 22 of 25 tumors. Small-volume tumor (one patient with gastric adenocarcinoma, and one patient with lymphoma) and coexistent infiltrative adenocarcinoma and gastritis (one patient) rendered demonstration of tumor poor on MR images in three patients. Tumors were mildly hypointense on T1-weighted images and mildly hyperintense on T2-weighted images. Tumors enhanced in a heterogeneous fashion compared with background stomach wall, but they ranged from hypointense to hyperintense on early and late post-gadolinium SGE images. Regarding benign diseases, the changes of gastritis were evident in three of four cases. Gastritis appeared as increased mucosal enhancement that ranged from moderate to intense on early and late post-gadolinium SGE images. Imaging findings of the various entities are described in greater detail in the text. MR findings in a variety of neoplastic and non-neoplastic diseases of the stomach are described. Neoplastic diseases were consistently observed in most cases; however, small tumors and tumors coexistent with inflammatory changes were poorly evaluated. The changes of gastritis were demonstrated as increased enhancement of the gastric wall. J. Magn. Reson. Imaging 10:950-960, 1999.  相似文献   

3.
This study demonstrates the appearance of large bowel diseases on magnetic resonance (MR) images using breath-hold T2-weighted half-Fourier acquisition snapshot turbo spin-echo (HASTE), breath-hold T1-weighted spoiled gradient-echo (SGE), and breath-hold gadolinium-enhanced T1-weighted SGE with and without fat-suppression sequences. The study represents a collective experience using a generalized combined abdominal-pelvic imaging protocol. Of 29 patients, 27 had surgical, endoscopic, microbiological, and/or histopathological correlation, and 2 had a diagnosis based on characteristic imaging findings. Fifteen patients had neoplastic disease including colon adenocarcinoma (n = 11), rectosigmoid carcinoid (n = 1), familial adenomatous polyposis (n = 2), and cecal lipoma (n = 1). Fourteen patients had non-neoplastic disease including diverticulosis (n = 6), ischemic colitis (n = 2), pseudomembranous colitis (n = 2), acute appendicitis with periappendiceal abscess (n = 2), Mycobacterium avium intracellulare (MAI) colitis (n = 1), and Crohn's proctocolitis (n = 1). In all 15 patients with neoplastic diseases, MR imaging depicted the primary lesions and demonstrated local extent. Mass lesions were best shown on T2-weighted HASTE and gadolinium-enhanced fat-suppressed SGE images. Of 14 patients with non-neoplastic diseases, inflammatory changes were best shown on gadolinium-enhanced fat-suppressed T1-weighted SGE images in all cases. MR imaging with fast scanning breath-hold techniques and intravenous gadolinium enhancement provided good depiction and characterization of large bowel diseases.  相似文献   

4.
This study describes the MR appearances of malignant hypervascular liver lesions pre- and post-hepatic-arterial chemoembolization, with correlation to serial imaging and clinical responses. Eight patients with malignant hypervascular liver lesions underwent pretreatment and posttreatment MR examination on a 1.5-T MR imager. MR sequences included T1-weighted spoiled gradient echo (SGE), T2-weighted fat-suppressed spin echo or turbo spin echo, and dynamic gadolinium-enhanced SGE images. All patients underwent pretreatment, initial posttreatment, and subsequent posttreatment MR studies. The histology of primary tumors included various types of hepatocellular carcinoma (HCC) (four patients: fibrolamellar HCC [one patient], HCC [two patients], mixed HCC/cholangiocarcinoma [one patient]) and liver metastases (four patients: untyped islet cell tumor [two patients], gastrinoma [one patient], carcinoid [one patient]). Response to chemoembolization was determined by three assessments: MR response, serial imaging response, and clinical response. The appearance of MR response to chemoembolization was determined based on the correlation with clinical and serial imaging response. The MR response of lesions that showed good clinical response included: increase in signal intensity on T1-weighted images (three patients), decrease in signal intensity on T2-weighted images (three patients), and negligible or minimal enhancement on immediate postgadolinium images (four patients) after chemoembolization. The most marked change in lesion appearance was observed in lesions < 1 cm, which had intense homogeneous enhancement on pretreatment MR studies and negligible enhancement on initial posttreatment MR examinations. MR response of lesions that showed moderate clinical response demonstrated a variety of lesion appearances from substantial change to minimal change. MR response of lesions that showed poor clinical response demonstrated no change in lesion appearances compared with the pretreatment MR study. Our results demonstrated change in appearance of liver lesions between pre- and post-hepatic-arterial chemoembolization MR studies. MR response correlated with response determined by serial imaging studies and clinical findings.  相似文献   

5.
Our purpose was to identify the histologic types of malignant liver lesions with high signal intensity (SI) on T1-weighted images and to describe the MR imaging features. Thirteen patients with malignant liver lesions high in SI on T1-weighted images were studied with a 1.5-T MR imager using pre- and serial postcontrast spoiled gradient-echo (SGE) sequences (all patients), T2-weighted fat-suppressed spin-echo sequences (all patients), precontrast T1-weighted fat-suppressed spin-echo sequences (five studies in five patients), and precontrast out-of-phase SGE sequences (seven studies in six patients). Images were reviewed retrospectively to determine number of lesions; lesion size; SI of lesions on T1-weighted, T2-weighted, and fat-attenuated T1-weighted images; distribution of high SI in lesions on T1-weighted images; and tumor enhancement pattern. Seven patients had multiple tumors high in SI on T1-weighted images and six patients had solitary tumors. Seventy-two lesions were less than 1.5 cm in diameter and 35 lesions were more than 1.5 cm in diameter. Nine patients had solid malignant lesions and four patients had cystic malignant lesions. All tumors more than 1.5 cm in diameter were heterogeneously high in SI on T1-weighted images, and all tumors less than 1.5 cm were completely homogeneous or homogeneous with a small central hypointense focus. All tumors were more conspicuous on T1-weighted fat-attenuated images, both on excitation spoiled fat-suppressed spin-echo or on out-of-phase SGE images with the exception of one fat-containing hepatocellular carcinoma (HCC). In one patient with melanoma metastases and one patient with multiple myeloma nodules, appreciably more lesions were detected on out-of-phase SGE images. Causes of hyperintensity were considered to be either fat, melanin, central hemorrhage, or high protein content, all of which may be seen in a variety of tumors. Fat-attenuation techniques are helpful in the detection of these lesions.  相似文献   

6.
The purpose of the study was to define the magnetic resonance (MR) imaging appearance of adrenocortical carcinoma (ACC) with current MR techniques. Eight patients with ACC underwent high-field-strength MR imaging with the following sequences: axial T1-weighted gradient echo, fat-suppressed T1-weighted spin echo, fat-suppressed T2-weighted spin echo, and gadolinium-enhanced T1-weighted gradient echo and fat-suppressed T1-weighted spin echo. Postcontrast images were also acquired in the sagittal (six patients) and coronal (three patients) planes. Out-of-phase gradient-echo images were obtained in two patients. Lesion morphology, signal intensity features, and presence of metastatic disease were retrospectively evaluated. MR imaging features of ACC included internal hemorrhage (seven of eight patients), central necrosis (seven of eight), and peripheral enhancing nodules (seven of eight). Out-of-phase images in two of two patients demonstrated signal loss compared with in-phase images, which may be a common feature of these tumors. Liver metastases were present in four patients. Consistent MR features of ACC are Identified.  相似文献   

7.
The purpose of this study was to evaluate the spectrum of appearances of gastrointestinal carcinoid tumors at magnetic resonance imaging (MRI) and to elucidate patterns of appearances of carcinoid liver metastases on precontrast and postgadolinium images. The MR examinations of 29 patients (11 men, 18 women; age range, 33-87 years) with histologically confirmed gastrointestinal carcinoid tumors, representing our complete 9.5 years of experience with this entity, were retrospectively reviewed. Twelve patients had MR examinations prior to resection or biopsy of the primary tumor (preoperative group); 17 patients were imaged postsurgically (postoperative group). All MR studies were performed at 1.5 T and comprised T1-weighted spoiled gradient echo (SGE), T2-weighted fat-suppressed turbo spin echo, HASTE, and serial postgadolinium T1-weighted SGE sequences without and with fat suppression. Morphology, signal intensity, and contrast enhancement of primary tumors and of metastases to the mesentery, peritoneum, and liver were evaluated. Primary tumors were visualized in 8 of 12 patients and best demonstrated on postgadolinium T1-weighted fat-suppressed images. The appearance of primary tumors was a nodular mass originating from the bowel wall (4 of 12 patients) or regional uniform bowel wall thickening (4 of 12 patients) with moderate intense enhancement on postgadolinium images. In 4 of 12 patients the primary tumor was prospectively not seen. Mesenteric metastases, seen in eight patients, presented as nodular masses and were associated with mesenteric stranding in seven patients. A total of 156 liver metastases were evaluated in 16 patients. On precontrast T1- and T2-weighted images, 117 metastases (75%) were hypointense and hyperintense, respectively. A total of 146 metastases (94%) were hypervascular, showing moderate intense enhancement during the hepatic arterial phase, and 9 metastases (6%) were hypovascular. Twenty-three metastases (15%) were visible only on immediate postgadolinium images. MRI is able to demonstrate findings in carcinoid tumors, including the primary tumor, mesenteric metastases, and liver metastases. Liver metastases are commonly hypervascular and may be demonstrable only on immediate postgadolinium images.  相似文献   

8.
This study describes the occurrence of hemorrhage in renal cancer in patients with chronic renal insufficiency as shown on MR images. Thirteen consecutive patients with chronic renal insufficiency who had his tologically proven renal cancer and underwent MRI at 1.5 T were entered in the study. MR examinations included spoiled gradient echo (SGE) and T1-weighted fat-suppressed imaging pre- and postgadolinium administration. All renal cancers were well shown on MR images and were most clearly depicted on postgadolinium T1-weighted fat-suppressed images. Tumors in 12 of 13 patients had regions of high signal intensity on precontrast T1-weighted images. Histology demonstrated intratumoral hemorrhage in all 12 of these patients. Four hemorrhagic tumors were largely cystic on imaging studies. One of these cancers altered in appearance from largely cystic with extensive hemorrhage to largely solid with substantial enhancement after a 2.5-year interval. Renal cancers demonstrated minimal enhancement (11 patients) on early postgadolinium images and were minimally enhanced on delayed images in 10 of 13 tumors. Two renal cancers demonstrated intense enhancement. Renal cancers are well shown on MR images in patients with chronic renal insufficiency. Because of the common occurrence of hemorrhage into renal cancers in patients with renal insufficiency, caution should be exercised when evaluating hemorrhagic cystic lesions in these patients.  相似文献   

9.
The authors reviewed their 21/2-year experience with a magnetic resonance (MR) imaging protocol for a 1.5-T MR imager that included T2-weighted fat-suppressed spin-echo, T1-weighted breath-hold gradient-echo, and serial dynamic gadolinium-enhanced T1-weighted gradient-echo imaging to identify histologic types of malignant liver lesions more apparent on T1- than on T2-weighted images. MR images of 212 consecutive patients with malignant liver lesions were reviewed. T2-weighted, T1-weighted, and dynamic contrast-enhanced T1-weighted images were examined separately in a blinded fashion. Seven patients demonstrated liver lesions (lymphoma [two patients] and carcinoid, hepatocellular carcinoma, colon adenocarcinoma, transitional cell carcinoma, and melanoma [one patient each]) on T1-weighted images that were inconspicuous on T2-weighted images. In all cases, the lesions were most conspicuous on T1-weighted images obtained immediately after administration of contrast agent. Histologic confirmation was present for all seven patients. The consistent feature among these lesions was that they were hypovascular, due either to a fibrous stroma or to dense monoclonal cellularity. These results suggest that in some patients with hypovascular primary neoplasms, the lesions may be identified only on T1-weighted images, and that immediate postcontrast T1-weighted images are of particular value in demonstrating lesions.  相似文献   

10.
Levine D  Trop I  Mehta TS  Barnes PD 《Radiology》2002,222(3):652-660
PURPOSE: To compare T2-weighted breath-hold single-shot fast spin-echo (SE) and gadolinium-enhanced spoiled gradient-echo (GRE) MR imaging with contrast material administered orally and rectally for evaluating patients with Crohn disease. MATERIALS AND METHODS: Twenty-eight patients with Crohn disease received 2% barium sulfate and water enema. The abdomen and pelvis were imaged with transverse and coronal single-shot fast SE and gadolinium-enhanced spoiled GRE MR imaging. Two radiologists reviewed the two types of images for bowel disease. The extent, severity, and conspicuity of the disease were determined. Proof of bowel disease at MR imaging was compared with that at endoscopy, barium study, and surgery. Statistical analysis was performed with the McNemar test. RESULTS: Twenty-five of 28 patients had proven abnormal bowel segments. The per-patient sensitivity of gadolinium-enhanced spoiled GRE MR imaging for the two radiologists was 100% and 96% versus 60% and 60% (P <.05) with single-shot fast SE MR imaging. Gadolinium-enhanced spoiled GRE MR images depicted more segments (54 and 52 of 61 segments; sensitivity, 89% and 85%, respectively) of the diseased bowel than did single-shot fast SE MR images (31 and 32 of 61 segments; sensitivity, 51% and 52%, respectively; P <.001). Severity of Crohn disease was correctly depicted at gadolinium-enhanced spoiled GRE imaging in 93% of patients versus in 43% of patients at single-shot fast SE imaging. CONCLUSION: In patients with Crohn disease, gadolinium-enhanced fat-suppressed spoiled GRE MR imaging better depicted the extent and severity of intestinal disease compared with single-shot fast SE imaging.  相似文献   

11.
We describe the magnetic resonance (MR) findings in patients with gastrointestinal polyposis syndromes using breath-hold T1-weighted sequences, both standard and with fat suppression, prior to and following gadolinium administration, and breathing-independent single-shot half-Fourier RARE T2-weighted sequences. Six patients with gastrointestinal polyposis syndromes underwent MR examination to investigate for the presence of metastatic disease. The appearances of the gastrointestinal polyps on noncontrast T1-weighted spoiled gradient-echo (SGE), T2-weighted (half-Fourier RARE) images, and early and late gadolinium-enhanced SGE images were determined. Other gastrointestinal findings and extragastrointestinal disease were also evaluated. Patients with the following gastrointestinal polyposis syndromes were included: familial polyposis (n = 3), Peutz-Jeghers syndrome (n = 1), Gardner's syndrome (n = 1), and neurofibromatosis (n = 1). Polypoid lesions in all patients exhibited signal intensity comparable to bowel on noncontrast images and enhanced similar to bowel on early and late gadolinium-enhanced images. Polyps larger than 2 cm, observed in one patient with familial polyposis and the patient with Gardner's disease, showed mild heterogeneity on late gadolinium-enhanced fat-suppressed images. Multiple colonic polyps ranging from 5 mm to 3 cm in diameter were observed in patients with familial adenomatous polyposis. A solitary 1.5 cm polyp associated with entero-enteric intussusception was observed in the patient with Peutz-Jeghers syndrome. Gastric polyps ranging from 5 mm to 6 cm were observed in the stomach of the patient with Gardner's syndrome. Duodenal and jejunal neurofibromas ranging from 1 to 2 cm in diameter were present in the patient with neurofibromatosis. Extra gastrointestinal findings included an adrenal adenoma (1 patient), a pheochromocytoma (1 patient), and liver metastases (2 patients). Gastrointestinal polyps in patients with polyposis syndromes may be visualized on MR images employing breath-hold T1-weighted and breathing-independent snapshot T2-weighted techniques. Appreciation of polyp enhancement on post-gadolinium images is an important finding, which should help distinguish polyps from bowel contents.  相似文献   

12.
The potential of new high-field-strength magnetic resonance (MR) imaging sequences to evaluate bowel disease was investigated and compared with computed tomographic (CT) studies. Thirty-two patients were studied, 14 with known or suspected gastrointestinal tumors and 18 with known or suspected bowel inflammatory conditions. T1-weighted fat-suppressed spin-echo and breath-hold FLASH (fast low-angle shot) images were obtained before and after intravenous injection of 0.1 mmol/kg gadopentetate dimeglumine. Pathologic confirmation was obtained by biopsy (n = 18), surgical excision (n = 8), or endoscopy (n = 6). CT and MR images were analyzed separately in a prospective fashion and reviewed by consensus. Information from CT and MR images was comparable in cases of confirmed bowel neoplasia. CT scans had better spatial resolution, while fat-suppressed gadolinium-enhanced MR images had better contrast resolution. In the 18 cases of bowel inflammation, CT scans showed concentric wall thickening in 16, while MR images showed concentric wall thickening in 14 and increased contrast enhancement in 17. Contrast enhancement was better appreciated on fat-suppressed images than on FLASH images. The results suggest that MR imaging may play a role in the evaluation of bowel disease.  相似文献   

13.
The purpose of this study is to compare the usefulness of conventional MR imaging and gadopentetate dimeglumine enhanced fat-suppressed MR imaging for the depiction and staging of rectal carcinoma. Thirty-two patients were prospectively evaluated by MR imaging using a 1.5-T unit. Based on the results of a barium study and/or digital examination, a balloon catheter was inserted to the level of the lesion before examination. Both conventional T1- and T2-weighted images and gadopentetate dimeglumine enhanced fat-suppressed T1-weighted images were obtained for all patients. The kappa statistics were performed for the evaluation of interobserver agreement and the McNemar test was performed for the analysis of staging accuracy. When only T1- and T2-weighted images were used, 5 of 32 tumors were not detected and the extent of 18 of 32 tumors were unclear. However, when gadopentetate dimeglumine enhanced fat-suppressed imaging was added, 24 of 32 tumors were well defined and only one tumor was not detected. In determining the depth of invasion, the staging accuracy was 72% for conventional imaging and 68% for all images combined. There was no significant difference between with gadopentetate dimeglumine fat-suppressed imaging and conventional imaging (P > .05). Use of gadopentetate dimeglumine (fat-suppressed imaging) resulted in overestimation of muscular invasion, peri-rectal fat invasion, and adjacent organ invasion in 12 patients, whereas nine patients were overestimated without the use of gadopentetate dimeglumine. In the detection of metastatic lymph nodes, gadopentetate dimeglumine enhanced fat-suppressed imaging also was not useful. Tumor detection was excellent using gadopentetate dimeglumine enhanced fat-suppressed images. However, the accuracy of staging was not improved by obtaining such images.  相似文献   

14.
PURPOSE: To assess the value of functional magnetic resonance (MR) imaging in the evaluation of early tumor response after transarterial chemoembolization (TACE) for metastatic leiomyosarcoma and compare tumor response using functional MR imaging versus traditional imaging response assessment, which is based on tumor size. MATERIALS AND METHODS: We evaluated 31 lesions in 10 patients with liver metastases from leiomyosarcoma using MR imaging studies before and after TACE. Diffusion and contrast-enhanced MR imaging was performed on a 1.5-T unit. Imaging protocol consisted of T2-weighted fast spin-echo images, breath-hold diffusion-weighted echo-planar images, and breath-hold unenhanced and contrast-enhanced T1-weighted 3-dimensional fat-suppressed spoiled gradient-echo images in the arterial phase (20 seconds) and portal venous phase (60 seconds). Parameters evaluated included change in tumor size, enhancement, and apparent diffusion coefficient (ADC) values. Median survival was also calculated for the entire cohort. RESULTS: The 31 lesions evaluated had a mean size of 4.8 cm before treatment. Tumor size decreased only by 2% immediately after treatment. Decrease of tumor enhancement after treatment was significant (P < 0.0001) in the arterial phase (69%) as well as in the portal venous phase (64%). After TACE, mean tumor ADC increased by 20% (P = 0.0015), whereas mean nontreated liver, spleen, and muscle ADC values did not change significantly (P = 0.44, P = 0.287, and P = 0.098, respectively). Patient survival from time of first TACE was 21 months for the entire cohort. CONCLUSION: In patients with leiomyosarcoma and liver metastases who were treated with TACE, significant early changes in the treated lesions occurred on functional MR imaging. These include decrease in tumor enhancement and increase in tumor ADC value, suggesting increasing tumor necrosis and cell death. Changes in tumor size were small and inadequate to assess treatment response, suggesting limitation of the current response criteria in the early assessment of tumor response.  相似文献   

15.
PURPOSE: To evaluate peripancreatic signal changes on fat-suppressed T1-weighted spoiled gradient echo images associated with acute pancreatitis and investigate potential utility in regards to relationship to clinical outcome. MATERIALS AND METHODS: The abdominal MR images in 31 patients with acute pancreatitis were reviewed, and evaluated for the presence of elevated signal intensity within the peripancreatic fat on fat-suppressed T1-weighted spoiled gradient echo images; the degree of signal changes was graded as mild, moderate, or severe. RESULTS: Ten of 31 patients demonstrated abnormal high signal intensity in the peripancreatic fat on fat-suppressed T1-weighted images. The degree of signal change was mild in three patients, moderate in one, and severe in six patients. All six patients with severe elevated peripancreatic soft tissue signal died within seven to 68 days (mean, 47 days) of their admission. All 21 patients without elevated peripancreatic fat signal survived without any complications. The correlation between the presence and severity of elevated peripancreatic MR signal and patient outcome was significant (P < 0.05). CONCLUSION: Elevated peripancreatic signal on fat-suppressed T1-weighted images is associated progressively with poor outcome in patients with acute pancreatitis, and may represent a simplified method for prognostic cross-sectional imaging.  相似文献   

16.
OBJECTIVE: The purpose of this study was to determine the accuracy of a multiphasic gadolinium-enhanced three-dimensional (3D) fast spoiled gradient-recalled echo sequence alone in the detection and characterization of focal liver lesions compared with a comprehensive liver evaluation using multiphasic gadolinium-enhanced 3D fast spoiled gradient-recalled echo, T1-weighted, and fat-suppressed fast spin-echo T2-weighted sequences. MATERIALS AND METHODS:A retrospective review of abdominal MR imaging examinations in 61 patients was performed. All MR examinations included unenhanced spin-echo T1-weighted, unenhanced fat-suppressed fast spin-echo T2-weighted, and multiphasic gadolinium-enhanced 3D fast spoiled gradient-recalled echo sequences obtained during successive breath-holds. The liver was evaluated for focal lesions first with the 3D spoiled gradient-recalled echo sequences and then, during a separate sitting, with the T1- and T2-weighted sequences. The usefulness of each sequence in the detection and characterization of lesions was recorded. The gold standard for lesion detection and characterization was all three imaging sequences reviewed together. RESULTS:A total of 114 focal liver lesions were identified, 54 of which were simple cysts. The 3D spoiled gradient-recalled echo sequence alone detected 92 (81%) of the 114 lesions, and the T1- and T2-weighted sequences detected 95 (83%) of the 114 lesions. Of the 60 lesions that were not simple cysts, the 3D spoiled gradient-recalled echo sequence alone detected 58 (97%), and T1- and T2-weighted sequences detected 51 (85%). In 24% of the patients with lesions, the T1- and T2-weighted sequences were found to be helpful for the characterization of lesions. CONCLUSION:A multiphasic contrast-enhanced 3D fast spoiled gradient-recalled echo sequence alone detects most of the clinically relevant focal liver lesions. Additional liver examination using both unenhanced T1- and T2-weighted sequences is helpful for lesion characterization but increases the detection rate only minimally.  相似文献   

17.
Nonenhanced and gadolinium-enhanced fat-suppressed spin-echo and breath-hold fast low-angle shot (FLASH) magnetic resonance (MR) imaging techniques were compared with iodine contrast material-enhanced computed tomography (CT) for the detection and characterization of renal masses. MR studies included T1-weighted fat-suppressed spin-echo (T1FS) and FLASH images followed by rapid injection of gadopentetate dimeglumine and a repeated FLASH image obtained at 1 second, a T1FS image at 30 seconds, and a FLASH image at 10 minutes. Of 38 patients, 17 had renal cysts, 18 had solid tumors, two had cortical scarring, and one had a hypertrophied column of Bertin. With contrast-enhanced T1FS, contrast-enhanced FLASH, and CT images, 114, 110, and 109 lesions, respectively, were detected. With MR imaging and CT, cysts smaller than 5 mm in diameter and solid tumors as small as 1 cm in diameter were detected. With combined contrast-enhanced FLASH and T1FS images, 112 lesions were correctly characterized as cystic or solid; with nonenhanced T1FS images, 110; with nonenhanced FLASH images, 107; and with nonenhanced CT, 103.  相似文献   

18.
The purpose of this paper was to evaluate the use of dynamic gadopentetate dimeglumine-enhanced, breath-hold spoiled gradient-recalled (SPGR) MR imaging with cardiac compensation (CMON) compared to spin-echo MR imaging in patients with thoracic malignancy. We retrospectively reviewed MR images from 29 patients with thoracic tumors. MR imaging included axial electrocardiogram (ECG)-gated T1-weighted, fast spin echo (FSE) T2-weighted, and contrast-enhanced breath-hold fast multiplanar SPGR imaging with CMON, which selects the phase-encoding gradient based on the phase within the cardiac cycle. Images were reviewed for lung masses, mediastinal or hilar tumor, disease of the pleura, chest wall, and bones, and vascular compression or occlusion. Contrast-enhanced fast multiplanar SPGR imaging with CMON produces images of the chest that are free of respiratory artifact and have diminished vascular pulsation artifact. ECG-gated T1-weighted images were preferred for depicting mediastinal and hilar tumor. The gadopentetate dimeglumine-enhanced fast multiplanar SPGR images were useful for depicting chest wall tumor, vascular compression or thrombosis, osseous metastases, and in distinguishing a central tumor mass from peripheral lung consolidation. Pleural tumor was depicted best on the FSE T2-weighted images and the contrast-enhanced SPGR images. As an adjunct to spin echo T1-weighted and T2-weighted imaging, contrast-enhanced fast multiplanar SPGR imaging with CMON is useful in the evaluation of thoracic malignancy.  相似文献   

19.
PURPOSE: To determine the sensitivity and specificity of magnetic resonance (MR) imaging for depicting pancreatic small, functional islet cell tumors and the minimum number of sequences for expedient diagnosis. MATERIALS AND METHODS: Twenty-eight patients clinically suspected to have functional islet cell tumors underwent T1- and T2-weighted spin-echo (SE) MR imaging with and without fat suppression, T2-weighted fast SE imaging, and spoiled gradient-echo (GRE) imaging before and after injection of gadopentetate dimeglumine. Sensitivity, specificity, and the best and minimum number of sequences for definitive diagnosis were determined. RESULTS: MR images depicted proved islet cell tumors in 17 of 20 patients (sensitivity, 85%). Images were true-negative in eight patients with negative follow-up examination results for more than 1 year. Specificity was 100%; positive predictive value, 100%; and negative predictive value, 73%. Among 20 patients with tumor, T1-weighted SE images with fat suppression and nonenhanced spoiled GRE images each showed lesions in 15 (75%); T2-weighted conventional SE with fat suppression, in 13 (65%); gadolinium-enhanced spoiled GRE, in 12 (60%); and T2-weighted fast SE, in seven of 10 patients (70%). CONCLUSION: MR imaging accurately depicts small islet cell tumors. T2-weighted fast SE and spoiled GRE sequences usually suffice. Gadolinium-enhanced sequences are needed only if MR imaging results are equivocal or negative.  相似文献   

20.
PURPOSE: To describe the magnetic resonance imaging spectrum of appearances of liver metastases from pancreatic ductal adenocarcinoma. MATERIALS AND METHODS: We retrospectively evaluated the MRI exams performed between July 1996 and August 2001 in all patients who had liver metastases from pancreatic adenocarcinoma and histopathologic diagnosis from either the primary pancreatic tumor, liver metastases, or both. Sixteen patients were included in the study. All MR studies were performed at 1.5 T with a standard protocol including T1- and T2-weighted images and serial post-gadolinium spoiled gradient echo (SGE) images. Location, size, number, signal characteristics on T1- and T2-weighted images, and pattern of enhancement on serial gadolinium-enhanced SGE images were assessed. RESULTS: The diameter of metastases ranged from a few millimetres to 4 cm, and 12 patients (75%) had only lesions of 1.5 cm or less. Capsular-based liver metastases were found in 13 patients (81%) and three patients had only capsular-based lesions with a diameter under 1.5 cm. Hypervascular lesions were found in six patients (38%) and hypovascular lesions in 10 patients (62%). Perilesional enhancement was present in 10 patients (62%), with six patients (38%) having ring perilesional enhancement and eight patients (50%) having wedge-shaped perilesional enhancement. CONCLUSION: On MR imaging, hepatic metastases from pancreatic adenocarcinoma show a range of enhancement patterns. Hypervascular metastases are not rare. Capsular based distribution, small diameter, and perilesional enhancement are common features. This retrospective study describes the MR imaging spectrum of appearances of liver metastases from pancreatic adenocarcinoma in patients with histopathologic confirmation of the diagnosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号