首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.

Objective

The success of removable partial dentures (RPDs) is partly dependent on patients’ acceptance and compliance in using them. The purpose of this study was to describe the usage of removable partial dentures (RPDs) by patients 1 year after insertion and to evaluate the factors that influence their denture usage.

Methods

Forty-seven patients who received 75 new RPDs at the undergraduate clinic of College of Dentistry, King Saud University, were contacted by telephone 1 year later for an interview. The questions covered denture usage, patient’s satisfaction and reasons for non-use.

Results

Results showed that 36% of patients discarded or occasionally used their RPDs. There was no significant association between denture usage and RPD experience, location or Kennedy classification. A significantly more RPD rejection was found when it was opposed by natural teeth or complete denture. The most quoted reason for RPD rejection was pain and discomfort.

Conclusion

Despite the short follow-up period, RPDs were poorly accepted by patients treated by undergraduate students.  相似文献   

2.

Objective

The purpose of this study was to determine whether there is a correlation between the clinical quality of conventional complete dentures and patient quality of life.

Materials and methods

This study included a random sample of 32 completely edentulous patients (15 males and 17 females) who were treated with conventional complete dentures. Using a validated questionnaire, three investigators evaluated the dentures independently on the basis of seven clinical parameters: esthetics (lip support and lower lip line), retention and stability of the maxillary and the mandibular dentures, and occlusion. Patients completed the validated Oral Health Impact Profile-20 (OHIP-20) questionnaire. Correlations were determined by using the point-biserial correlation coefficient.

Results

Clinicians rated the overall clinical quality of the dentures satisfactory in 80.3% of patients. The mean (±standard deviation) total OHIP-20 score was 56.3 ± 15.9 out of a possible 120 maximum. A statistically significant negative correlation was found between the stability of the maxillary and mandibular dentures and the total OHIP-20 score (p = 0.009 and 0.0023, respectively). A negative correlation between the total OHIP-20 score and the retention of the mandibular denture approached significance (p = 0.092). Esthetics, retention of the maxillary denture, and occlusion were not correlated with patient quality of life (p > 0.169).

Conclusion

Stability of the maxillary and mandibular dentures is the denture quality parameter that can most significantly affect patient quality of life.  相似文献   

3.

PURPOSE

The midline fracture of maxillary complete dentures is a frequently encountered complication. The purpose of this study was to assess the effect of frenulum height on midline strains of maxillary complete dentures.

MATERIALS AND METHODS

A removable maxillary complete denture was fabricated and duplicated seven times. Four different labial frenulum heights were tested for stresses occurring on the palatal cameo surface. The strains were measured with strain gauges placed on 5 different locations and the stresses were calculated. To mimic occlusal forces bilaterally 100 N of load was applied from the premolar and molar region.

RESULTS

A statistically significant association between the height of the labial frenulum and the calculated stresses and strains was shown (P<.05) predominantly on the midline and especially on the incisive papilla. The results showed that stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum.

CONCLUSION

Within the limitations of this in vitro study, it can be concluded that the stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. Surgical or mechanical precautions should be taken to prevent short-term failure of maxillary complete dentures due to stress concentration and low cycle fatigue tendency at the labial frenulum region.  相似文献   

4.

Objective

Effective cleaning of dentures is important for the maintenance of good oral hygiene for denture stomatitis patients. The in vivo efficacy of three different brands of alkaline peroxide tablets (Polident, Efferdent, and Fittydent) and two mouthwashes (CloSYS II and Corsodyl) to eliminate Candida albicans on dentures was evaluated in this in vivo study.

Material and methods

Ninety denture wearers with clinical evidence of denture stomatitis were randomly divided into 5 test groups and 1 control group. Each group was further divided into three subgroups in which the dentures were subjected to 15-, 30-, and 60-min disinfection procedures. The dentures of each test group were treated with one of the cleaners, while those of the control group were treated with distilled water. Swab samples from the palatal surfaces (2 cm x 2 cm template delimited area) of the upper dentures were obtained before and after 15, 30, and 60 min periods of cleaner use and examined mycologically.

Results

The reduction in the number of colony-forming units (CFU) of C. albicans before, and after 15, 30, and 60 min of use of CloSYS II and Corsodyl was significantly greater than that of the control group (p<0.05). Moreover, there was no statistically significant difference (p>0.05) among Polident, Efferdent and the control group in any of the treatment periods. Dentures treated with Fittydent appeared to have a significantly greater reduction in the number of Candida spp. only after 60 min of treatment.

Conclusions

The results of this study showed that the use of mouthwashes significantly reduced the number of microorganisms on dentures.  相似文献   

5.

Objective

The aim of this study was to evaluate the effect of repeated microwave disinfections on the dimensional stability of acrylic dentures.

Materials and Methods

Three groups of dentures made of a heat polymerized acrylic resin were tested. I: dentures kept in water (control group). II: dentures microwaved daily while being immersed into water (wet disinfection). III: dentures microwaved daily without being immersed into water (dry disinfection).
Measurements were taken across three reference points, on two occasions: after curing and immersion in water for 24 hours, and one week later.
Data obtained were analyzed using one-way analysis of variance (ANOVA) and Scheffe’s multiple range test.

Results

The results showed that the microwave disinfection provokes dimensional changes of the same pattern (shrinkage). The dentures which underwent wet disinfection exhibited the greatest shrinkage (p<0.05).

Conclusions

Disinfection using microwave energy may cause dimensional changes (shrinkage) of complete dentures.
The microwave “dry disinfection” method can be safely applied in everyday practice since the dimensional changes which occurred seem to be of no clinical significance.Key words: Complete Dentures, Acrylic Resins, Disinfection, Microwaves, Dimensional Measurement Accuracy  相似文献   

6.

Statement of Problem:

The occurrence porosity in polymethyl methacrylate, the most commonly used denture base material is a problem. The occurrence of oral candidiasis and other infections has also been reported in denture users.

Purpose:

The aim of this study was to evaluate the effect of addition of an antimicrobial agent, silver zeolite on the porosity of denture base resin, which will be an effective tool in the prevention of oral candidiasis among denture wearers. This study also aims to analyze the effect of polymerization technique on porosity in zeolite incorporated dentures to develop a denture base resin which will be easy to process with optimal mechanical and antimicrobial properties.

Materials and Methods:

Eighty rectangular resin specimens (65 mm × 40 mm × 5 mm) were divided into one control group (A) and three experimental groups (B – Microwave cured denture base resin specimens, C – Conventionally cured denture base resin incorporated with antibacterial zeolites, D – Microwave cured denture base resin incorporated with antibacterial zeolites) porosity was calculated by measurement of the specimen volume before and after its immersion in water. Data were analyzed using one-way analysis of variance.

Results:

The mean values of the percent mean porosity were: A = 0.9555%, B = 0.9590%, C = 0.9630%, D = 0.9695%. No significant differences were found in mean porosity among the groups evaluated.

Conclusion:

Within the limitations of this study, it could be concluded that the addition of zeolites did not result in significant porosity and that the use of microwave processing is a viable option for denture processing.Key Words: Microwave, polymethyl methacrylate, zeolites  相似文献   

7.

Objective:

The purpose of this in vitro study was to evaluate the internal adaptation of Class V composite restorations to the cavity walls using three different techniques of polymerization.

Methods:

Standard cavities were prepared on the buccal and lingual surfaces of 24 extracted human third molars with margins located above and below the cementoenamel junction. Restorations were placed in one increment using two restorative systems: 3M Filtek A110/ Single Bond (M) and 3M Filtek Z250/ Single Bond (H) in the same tooth, randomly in the buccal and lingual surfaces. Resin composites were polymerized using three techniques: Group 1 – Conventional (60 s - 600 mW/cm2); Group 2 – Soft-start (20 s – 200 mW/cm2, 40 s - 600 mW/cm2); Group 3 – Pulse Activation (3 s - 200 mW/cm2, 3-min hiatus, 57 s - 600 mW/cm2). Buccolingual sections were polished, impressions taken and replicated. Specimens were assessed under scanning electron microscopy up to X1000 magnification. Scores were given for presence or absence of gaps (0 – no gap; 1 – gap in one wall; 2 – gap in two walls; 3 – gap in three walls).

Results:

The mean scores of the groups were (±SD) were: G1M–3.0 (± 0.0); G2M–2.43 (± 0.8); G3M– 1.71 (± 0.9); G1H– 2.14 (± 1.2); G2H- 2.00 (± 0.8); G3H- 1.67 (± 1.1). Data were analyzed using Kruskal-Wallis and Dunnet’s tests. No statistically significant difference (p>0.05) was found among groups. Gaps were observed in all groups.

Conclusions:

The photocuring technique and the type of resin composite had no influence on the internal adaptation of the material to the cavity walls. A positive effect was observed when the slow polymerization techniques were used.  相似文献   

8.

Purpose:

In the authors’ experience, the color of silicone elastomer following polymerization in molds made of gypsum products is slightly different from the color that was matched in the presence of the patient, before the silicone is packed. It is hypothesized that the investing materials and separating media have an effect on the color during the polymerization process of the silicone.

Materials and Methods:

This study compares and evaluates the change in color of silicone elastomer packed in three commonly used investing materials - Dental stone (white color), dental stone (green color), and die stone (orange color); coated with three different separating media – Alginate-based medium, soap solution and a resin-based die hardening material. Pigmented silicone samples of dimensions 1.5 cm × 2 cm × 0.5 cm were made from the elastomer in the above-mentioned mold materials using combinations of the mentioned separating media. These served as test group samples. Control group samples were made by packing a mix of the same pigmented elastomer in stainless steel molds. The L*, a*, b* values of the test and control group samples were determined using a spectrophotometer. The change in color (Delta E) was calculated between the control and test groups.

Results:

The mean L, a, b values for the control group were, 31.8, 26.2, and 36.3, respectively. Average values of change in color (Delta E) for samples packed utilizing alginate-based medium, die hardener, and soap solution, respectively in white dental stone (2.70, 2.74, and 2.88), green dental stone (2.19, 2.23, 2.42), and orange die stone (3.19, 2.72, 2.80) were tabulated.

Conclusion:

Among the investing materials studied, die stone showed the most color change (3.19), which was statistically significant. Among the separating media, die hardener showed the least color change (2.23). The best combination of an investing material and separating media as per this investigation is a dental stone (green) and alginate-based separating medium.  相似文献   

9.

PURPOSE

The purpose of this clinical study was to evaluate the frequency and type of prosthetic complications in relation to type and properties of removable dentures and to investigate the influence of these complications and several data about the existing dentures on patient satisfaction.

MATERIALS AND METHODS

Ninety nine patients (44 males and 55 females) wearing removable dentures have been included in the study. The complications of the patients were recorded; patient satisfaction was determined with a Visual Analog Scale (VAS) and the relationship of complications and patient satisfaction with several data about the dentures such as denture age, type of denture, centric relation and vertical dimension was investigated. Kruskal Wallis, Mann Whitney U and Chi square tests were used for statistical analyses. The results were evaluated statistically at a significance level of P<.05.

RESULTS

Need for addition of artificial teeth for dentures with correct centric relations was found to be significantly lower than dentures with wrong centric relations (P<.01). Loss of retention, ulcerations and high vertical dimension affected the VAS chewing ability scores negatively and ulcerations affected the VAS phonation scores negatively (P<.05).

CONCLUSION

Considering the results of this study, it can be concluded that loss of retention, ulcerations and high vertical dimension caused patient dissatisfaction. Additionally, dentures with wrong centric relations caused need for addition of artificial teeth.  相似文献   

10.

Objective:

The purpose of this study was to compare the fracture resistance of implant-supported all-ceramic fixed partial dentures, which have three different pontic designs.

Material and Methods:

Two implants were placed in a metal model simulating mandibular left second premolar and mandibular left second molar. Thirty standardized 3-unit all-ceramic fixed partial dentures with biconvex, convex or concave pontic designs were fabricated using IPS e.max system (n=10). Afterwards, specimens were centrally loaded on the pontics until failure with a universal testing machine. Results were analyzed by Kruskal-Wallis and Mann-Whitney U tests at 5% significance level.

Results:

The fracture resistance values of all-ceramic fixed partial dentures designed with biconvex, convex or concave pontics were 349.71, 438.20 and 300.78 N, respectively. There were no statistically significant differences between the fracture resistances of the groups (p>0.05), except for convex and concave groups (p<0.05 and p=0.009, respectively).

Conclusions:

Convex design showed the best mechanical properties as demonstrated by the high values of fracture resistance.  相似文献   

11.

PURPOSE

Study was conducted to determine and assess the effect of different type of denture adhesives on the incisal bite force of complete denture wearers until the dislodgement of upper denture, using pressure transducer.

MATERIALS AND METHODS

30 patients out of 100 were included in the study. Based on the Kapur''s method of scoring denture retention and stability, these patients were divided into 3 groups- Group A - Clinically good dentures; Group B - Clinically fair dentures; and Group C - Clinically poor dentures. A custom made occlusal force meter was constructed based on the load cell type of pressure transducers. Different adhesives (powder, paste and adhesive strips) were used in the study. Complete denture wearers were asked to bite on the load cell and the readings of incisal bite force were recorded. The readings of incisal bite force were subjected to statistical analysis using Repeated measures ANOVA followed by post-hoc bonferroni test.

RESULTS

The result suggests that denture adhesives improved the incisal bite force of complete denture wearers significantly The incisal bite force (in kg) in Group A without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 2.48 (± 0.16), 3.43 (± 0.11), 6.01 (± 0.11), 3.22 (± 0.09) respectively. The incisal bite force (in kg) in Group B without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 1.87 (± 0.18), 3.35 (± 0.14), 5.34 (± 0.18), 3.21 (± 0.12) respectively. The incisal bite force (in kg) in Group C without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 1.00 (± 0.17), 3.07 (± 0.14), 4.37 (± 0.26), 2.99 (± 0.14) respectively.

CONCLUSION

Within the limitations of the study, it was concluded that the use of denture adhesive was found to be significantly effective in improving the incisal bite force of complete dentures until the dislodgement of upper denture. Fittydent paste adhesive was found to be more effective than the powder and strips adhesives. The improvement in incisal bite force was found to be higher in Group C in comparison to that of Group A and Group B.  相似文献   

12.

PURPOSE

The aim of this study was to measure the changes on the marginal and internal adaptation of zirconia based anterior fixed partial dentures after the porcelain firing process.

MATERIALS AND METHODS

A total of 34 anterior fixed partial dentures using LAVA CAD/CAM system (3M ESPE, Germany) were applied. Two silicone replicas were obtained: one is obtained before porcelain firing process (initial) and the other is obtained after porcelain firing process (final), followed by the examination under a binocular stereomicroscope. Kruskal Wallis and Wilcoxon Signed Ranks tests were used for the statistical analysis (P<.05).

RESULTS

No statistically significant difference was found between initial and final marginal gap values (P>.05). At the internal gap measurements, final marginal area values (59.54 µm) were significantly lower than the initial marginal area values (68.68 µm)(P<.05). The highest and the lowest internal gap values were observed at the incisal/occlusal area and at the marginal area, respectively. In addition, lower internal gap values were obtained for canines than for central incisors, lateral incisors and premolars at the incisal area (P<.05).

CONCLUSION

The firing cycles did not affect the marginal gap of Lava CAD/CAM system, but it is controversial for the internal gap.  相似文献   

13.

Objective:

The aim of this study was to correlate the presence of Enterobacteriaceae, Pseudomonadaceae, Moraxellaceae and Xanthomonadaceae on the posterior dorsum of the human tongue with the presence of tongue coating, gender, age, smoking habit and denture use.

Material and Methods:

Bacteria were isolated from the posterior tongue dorsum of 100 individuals in MacConkey agar medium and were identified by the API 20E system (Biolab-Mérieux).

Results:

43% of the individuals, presented the target microorganisms on the tongue dorsum, with greater prevalence among individuals between 40 and 50 years of age (p = 0.001) and non-smokers (p=0.0485).

Conclusions:

A higher prevalence of Enterobacteriaceae and Pseudomonadaceae was observed on the tongue dorsum of the individuals evaluated. There was no correlation between these species and the presence and thickness of tongue coating, gender and presence of dentures.  相似文献   

14.

Objectives:

This study evaluated by three-dimensional finite element analysis the tensions generated by different disocclusion patterns (canine guide and bilateral balanced occlusion) in an implant-supported mandibular complete denture.

Material and Methods:

A three-dimensional model of implant-supported mandibular complete denture was fabricated according to the Brånemark protocol. A 5-element 3.75 x 13-mm screw-shape dental implant system was modeled for this study. The implants were located in the intermental foramen region with 3-mm-high prosthetic components joined by a nickel-chromium framework with 12-mm bilateral cantilever covered by acrylic resin and 12 acrylic denture teeth. SolidWorks® software was used before and after processing the simulations. The mechanical properties of the components were inserted in the model and a 15 N load was established in fixed points, in each one of the simulations. Data were collected in the entire nickel-chromium framework. The results were displayed three-dimensionally as color graphic scales.

Results:

The canine guide generated greater tensions in the region of the first implant, while the bilateral balanced occlusion generated great tensions in the entire metallic framework. The maximum tension found in the simulation of the bilateral balanced occlusion was 3.22 fold higher than the one found in the simulation of the disocclusion in canine guide.

Conclusion:

The pattern of disocclusion in canine guide is the ideal for implant-supported mandibular complete denture.  相似文献   

15.

Background

Fractures of acrylic resin dentures are a common occurrence in clinical dentistry. The denture may be fractured accidentally when dropped or while in service in the mouth due to flexural fatigue.

Objectives

The aim of this study was to compare the elastic modulus and the flexural strength between two heat-cured acrylic resins used in denture bases: a high-impact resin (Lucitone 199) and a traditional resin (Rodex).

Materials and methods

Rectangular strips of Lucitone 199 and Rodex (10 samples each) were fabricated and stored in artificial saliva at 37 °C for 2 weeks. The specimens were subjected to a three-point flexural test. The data were statistically analysed with Student’s t-test (p ⩽ .05).

Results

The high-impact acrylic resin had a lower elastic modulus (p = .000) and higher flexural strength (p = .001) compared to the traditional acrylic resin.

Conclusion

Within the limitations of this study, it can be concluded that the high-impact acrylic resin is a suitable denture base material for patients with clinical fracture of the acrylic denture.  相似文献   

16.

Background:

The issue of biomaterial-derived ionic release in various sites of the human body has attracted the interest of many investigators because of the possibility that debris or degradation products elicit a foreign body reaction or have a role in the induction of pathological processes.

Purpose:

The purpose was to evaluate the saliva of denture wearers after insertion of the prosthesis for leaching of metals from metallic denture.

Materials and Methods:

Total 20 subjects of age group of 40–60 years including both males (10) and females (10) were selected for the study. Total subjects were divided into 2 groups each containing 10 subjects, Group I (control group): Subjects having dentition intact up to second molar and free of any dental restoration; Group II (study group): Partially edentulous subjects rehabilitated with cast-metal removable partial denture. Saliva samples were taken at three stages that is, 1 h, 24 h and 72 h after the denture insertion from subjects of study group as well as from the control group. Atomic absorption spectroscopy (AAS) was used to estimate the concentration of elemental ions. Obtained data''s were analyzed using SPSS (Statistical Package for Social Sciences) version 15.0 statistical analysis software. The values were represented in a number (%) and mean ± standard deviation.

Results:

At 1 h, 24 h and 72 h after the denture insertion in study group, chromium (Cr) had statistically significant higher mean concentration as compared to manganese (Mn) (P < 0.001). Cr had maximum concentration (0.1479 + 0.0052) immediately after denture insertion while maximum concentration of Mn (0.1479 + 0.0052) was found 24 h after denture insertion.

Conclusion:

Metal-based dentures show maximum leaching immediately after wearing of the prosthesis which decreased significantly over the period of 3 days. Cr and Mn were the metal ions mainly found in saliva of cast partial denture wearer. No concentration of cobalt, molybdenum (Mo) and iron (Fe) was found in saliva of metal base denture wearer. There was a significant change in concentration of elutes in saliva in first 72 h/3 days making time an effective variable was observed.Key Words: Dental casting alloys, leaching, saliva  相似文献   

17.

Objective

Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins.

Material and Methods

Sixty disc-shaped specimens (40 mm x 3 mm) were fabricated from two different brands (Artiplus and Trilux) of denture tooth acrylic resin. The specimens from each brand (n=30) were randomly divided into 6 groups (n=5) and immersed in the following solutions: distilled water (control group) and 5 disinfecting solutions (1% sodium hypochlorite, 2% sodium hypochlorite, 5.25% sodium hypochlorite, 2% glutaraldehyde, and 4% chlorhexidine gluconate). Tooth color measurements were made by spectrophotometry. Before disinfection, the initial color of each tooth was recorded. Further color measurements were determined after subjecting the specimens to 7, 21, 30, 45, 60, and 90 immersion cycles in each tested solution. Color differences (ΔE*) were determined using the CIE L*a*b* color system. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) followed by Tukey tests. The significance level was set at 5%.

Results

There were statistically significant differences in ΔE* among the 5 disinfectants and water during the 90 cycles of immersion for both denture tooth acrylic resins. Distilled water promoted the greatest color change in both denture tooth acrylic resins, nevertheless none of tested disinfectants promoted ΔE* values higher than 1.0 on these acrylic materials during the 90 cycles of disinfection.

Conclusions

Repeated immersion cycles in disinfecting solutions alter ∆E* values, however these values do not compromise the color of the tested denture tooth acrylic resins because they are imperceptible to the human eye.  相似文献   

18.

Objective:

To evaluate the shaping ability of Reciproc and Twisted-File Adaptive systems in rapid prototyping replicas.

Material and Methods:

Two mandibular molars showing S-shaped and 62-degree curvatures in the mesial root were scanned by using a microcomputed tomography (μCT) system. The data were exported in the stereolitograhic format and 20 samples of each molar were printed at 16 µm resolution. The mesial canals of 10 replicas of each specimen were prepared with each system. Transportation was measured by overlapping radiographs taken before and after preparation and resin thickness after instrumentation was measured by μCT.

Results:

Both systems maintained the original shape of the apical third in both anatomies (P>0.05). Overall, considering the resin thickness in the 62-degree replicas, no statistical difference was found between the systems (P>0.05). In the S-shaped curvature replica, Reciproc significantly decreased the thickness of the resin walls in comparison with TF Adaptive.

Conclusions:

The evaluated systems were able to maintain the original shape at the apical third of severely curved mesial canals of molar replicas.  相似文献   

19.

Objective of work

Oral health–related quality of life (OHRQoL) as a multidimensional concept is affected by many factors. Therefore, the aim of this study was to determine which demographic and subjective factors are significantly affecting the OHRQoL among the elderly people wearing complete removable dental prostheses (CRDP).

Materials and Methods

This questionnaire-based study included 301 participants, residents of elderly care homes (in Zagreb and Slavonski Brod, Croatia) wearing maxillary and/or mandibular CRDP. The questionnaire used in this study consisted of two sections; the first section included questions giving general information and in the second section the Croatian version of Oral Health Impact Profile (OHIP)-49 questionnaire with 49 items representing seven OHIP domains was used.

Results

Participants were aged between 60–99 years, with average age of 74 ± 12.1 years. OHIP summary score was 26.5. The highest average OHIP mean values in the domain of functional limitation amounted to 6.7, physical pain 5.1, and physical disability 5.9. The participants’ age, education, profession, residence place size, type of CRDP, and the time of denture wearing period all statistically significantly affected OHRQoL (p < 0.05).

Conclusions

General and sociodemographic factors had a significant influence on the participant’s subjective perception of oral health and OHRQoL. Younger participants, participants from rural places, those with lower levels of education, and shorter period of denture wearing demonstrated a higher impact on OHRQoL.Key words: elderly, dental prosthesis, oral health, quality of life  相似文献   

20.

PURPOSE

The purpose of this study was to compare the coronal bone level and patient satisfaction in 1-implant and 2-implant assisted mandibular overdentures.

MATERIALS AND METHODS

Twenty patients who had maladaptive mandibular dentures were treated in this study. Patients were randomly divided into two groups. The first group received 1 implant (Simple line II, Implantium, South Korea) in their mandibular midline and the second group received 2 implants in their B and D regions (according to Misch''s category). If the primary stability of each implant was at least 60 ISQ, ball attachment was placed and denture relined with soft liner. After 6 weeks, retentive cap incorporated with hard acrylic resin. In the 6 and 12 months recalls, periapical digital radiograph were made and visual analogue scale questionnaires were used to record patient satisfaction. The Friedman test was done for comparing the presurgical and postsurgical parameters in each group and the U-Mann Whitney test (P<.05) was done for comparison of post-treatment results between the two groups.

RESULTS

All implants achieved sufficient primary stability to be immediately loaded. Patient satisfaction was high, and there were no significant differences between two groups (P>.05). In addition, mean marginal bone loss was 0.6 ± 0.67 mm in the first group and 0.6 ± 0.51 mm in the second group, after 12 month. Mean marginal bone loss showed no significant differences between two groups.

CONCLUSION

This preliminary one-year result indicated that mandibular overdentures anchored to a single implant can be a safe and cost-effective method as a starting step for implant-overdenture treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号