1.
Background: Contrast-enhanced magnetic resonance angiography (CE-MRA) is less prone to flow-related signal intensity loss than three-dimensional time-of-flight (3D TOF) MRA and may therefore be more sensitive for detection of residual patency in platinum coil-treated intracranial aneurysms.

Purpose: To compare MRA and CE-MRA in the follow-up of intracranial aneurysms treated with platinum coils.

Material and Methods: CE-MRA and 3D TOF MRA (pre- and postcontrast injection) of the intracranial vasculature was performed at 1.5T in 38 patients (47 aneurysms) referred for DSA in the follow-up of coiled intracranial aneurysms.

Results: DSA showed aneurysm patency in 22/47 investigations. Patent aneurysm components were observed with CE-MRA in 18/22 cases, and with 3D TOF MRA in 21/22 cases. There was no significant difference in patent aneurysm component size between CE-MRA and 3D TOF MRA. In addition, CE-MRA showed six, 3D TOF MRA before contrast injection showed seven, and 3D TOF MRA after contrast injection showed eight cases with patent aneurysm components not observed on DSA.

Conclusion: 3D TOF MRA was highly sensitive for detection of patent aneurysm components, and at least as sensitive as CE-MRA. Residual aneurysm patency seems to be better visualized with MRA than with DSA in some cases.  相似文献   

2.
The diagnostic gain associated with image subtractions was assessed regarding contrast-enhanced 3D magnetic resonance angiography (MRA) image sets of the pelvic and lower extremity arteries. The MRA strategy combined a dedicated vascular coil with a single injection, two-station protocol. Voxel-by-voxel signal intensity subtraction was performed on MRA image sets obtained before and during dynamic infusion of a para-magnetic contrast agent. Non-subtracted and subtracted MRA image sets were assessed for the presence of occlusive (four grades) disease, using DSA as the standard of reference. In addition, SNR and CNR were recorded for each vascular segment on both the non-subtracted and subtracted images. While CNR values of subtracted images exceeded those of non-subtracted images (P < 0.05), there was no difference in diagnostic performance. For the detection of hemodynamically significant disease, non-subtracted and subtracted MRA provided overall sensitivity and specificity of 90.2%/90.3% and 95.1%/95.6%, respectively. Concordance between non-subtracted and subtracted MRA was excellent (Kappa = 0.86).  相似文献   

3.
Purpose: To compare three methods for standardizing volume rendering technique (VRT) protocols by studying aortic diameter measurements in magnetic resonance angiography (MRA) datasets.

Material and Methods: Datasets from 20 patients previously examined with gadolinium-enhanced MRA and with digital subtraction angiography (DSA) for abdominal aortic aneurysm were retrospectively evaluated by three independent readers. The MRA datasets were viewed using VRT with three different standardized transfer functions: the percentile method (Pc-VRT), the maximum-likelihood method (ML-VRT), and the partial range histogram method (PRH-VRT). The aortic diameters obtained with these three methods were compared with freely chosen VRT parameters (F-VRT) and with maximum intensity projection (MIP) concerning inter-reader variability and agreement with the reference method DSA.

Results: F-VRT parameters and PRH-VRT gave significantly higher diameter values than DSA, whereas Pc-VRT gave significantly lower values than DSA. The highest interobserver variability was found for F-VRT parameters and MIP, and the lowest for Pc-VRT and PRH-VRT. All standardized VRT methods were significantly superior to both MIP and F-VRT in this respect. The agreement with DSA was best for PRH-VRT, which was the only method with a mean error below 1 mm and which also had the narrowest limits of agreement (95% of cases between 2.1 mm below and 3.1 mm above DSA).

Conclusion: All the standardized VRT methods compare favorably with MIP and VRT with freely selected parameters as regards interobserver variability. The partial range histogram method, although systematically overestimating vessel diameters, gives results closest to those of DSA.  相似文献   

4.
Background: Retrobulbar hemodynamic alterations can occur during hemodialysis sessions, and patients with chronic renal failure may experience visual problems.

Purpose: To evaluate the effect of single-session hemodialysis on retrobulbar vessel hemodynamics by color Doppler ultrasonography.

Material and Methods: Thirty-five patients were included in the study. Retrobulbar blood flows were examined before and after dialysis sessions. Doppler spectral patterns of retrobulbar blood flow were evaluated. The t test for paired samples and the Wilcoxon matched-pairs signed-rank test were used for comparing the flow values before and after dialysis.

Results: Systolic and diastolic blood flow velocities of the ophthalmic artery, central retinal artery, central retinal vein, nasal posterior ciliary artery, and temporal posterior ciliary artery were found to be decreased bilaterally after hemodialysis sessions. No significant change was observed in resistivity index values after hemodialysis sessions.

Conclusion: Our findings reveal that retrobulbar circulation was disturbed after a single hemodialysis session.  相似文献   

5.
Background: The characterization of brain arteriovenous malformation (AVM) angioarchitecture remains rewarding in planning and predicting therapy. The increased signal-to-noise ratio at higher field strength has been found advantageous in vascular brain pathologies.

Purpose: To evaluate whether 3.0T time-of-flight (TOF) magnetic resonance angiography (MRA) is superior to 1.5T TOF-MRA for the characterization of cerebral AVMs.

Material and Methods: Fifteen patients with AVM underwent TOF-MRA at 3.0T and 1.5T and catheter angiography (DSA), which was used as the gold standard. Blinded readers scored image quality on a four-point scale, nidus size, and number of feeding arteries and draining veins.

Results: Image quality of TOF-MRA at 3.0T was superior to 1.5T but still inferior to DSA. Evaluation of nidus size was equally good at 3.0T and 1.5T for all AVMs. In small AVMs, however, there was a tendency of size overestimation at 3.0T. MRA at 3.0T had increased detection rates for feeding arteries (+21%) and superficial (+13%) and deep draining veins (+33%) over 1.5T MRA.

Conclusion: 3.0T TOF-MRA offers superior characterization of AVM angioarchitecture compared with 1.5T TOF-MRA. The image quality of MRA at both 3.0 and 1.5T is still far from equal to DSA, which remains the gold standard for characterization of AVM.  相似文献   

6.
Purpose: To assess the usefulness of three-dimensional (3D) angiography using rotational digital subtraction angiography (DSA) in transarterial embolization of hepatic tumors.

Material and Methods: Thirty-one 3D angiographies were conducted using rotational DSA during abdominal angiography for transarterial embolization of hepatic tumors. The quality of visualization of the tumor and feeder arteries as imaged by 3D angiography versus DSA anterioposterior (AP) images was compared.

Results: 3D rotational angiography provided excellent 3D visualization of the vascular structures of the hepatic artery, and was especially useful in patients with overlapping tumors on DSA AP images and in patients with complex vascular anatomies. Compared to DSA AP images, however, tumor stains could not be detected on 3D-A, but could be detected on DSA in four patients (13%). In 9 patients, feeding arteries could not be detected on 3D-A, but could be detected on DSA (29%).

Conclusion: 3D rotational angiography alone may not be suitable for pre-procedural mapping in transarterial embolization of hepatic tumors, but may be of value when information supplementary to DSA AP images is needed.  相似文献   

7.
Background: Magnetic resonance (MR) permits quantitative flow velocity measurements that could be used to detect changes in the curve profile downstream of a high-grade stenosis.

Purpose: To assess whether MR flow measurements can be used to detect iliac artery stenoses.

Material and Methods: Contrast-enhanced magnetic resonance angiography (MRA) and quantitative flow measurements in the lower aorta and proximal femoral arteries were performed in 29 patients with suspected iliac artery stenoses. Stenoses were graded into five degrees: 0%, 1-49%, 50-74%, 75-99%, and 100% diameter reduction. The femoral artery waveforms were evaluated qualitatively by two independent reviewers regarding peak systolic velocity (PSV), aortofemoral difference in time-to-peak (ΔTTP), systolic acceleration (SA), curve-shape index (CSI), and the presence of an early diastolic flow reversal. The correlation between these parameters and the degree of stenosis was assessed.

Results: A significant correlation with degree of stenosis was observed for the qualitative flow waveform evaluations, with a high degree of interobserver agreement (κ = 0.84). A significant correlation was also found between degree of stenosis and PSV, ΔTTP, SA, CSI, and presence of diastolic flow reversal. The flow velocity pattern, however, remained unchanged, both qualitatively and quantitatively, up to a stenosis degree of at least 75%.

Conclusion: Iliac artery stenoses cause femoral artery flow waveform changes that can be detected with MRI, but only at high-grade levels.  相似文献   

8.
Purpose: To evaluate the diagnostic accuracy of high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) of the supra-aortic arteries using the CareBolus technique. Digital subtraction angiography was the standard of reference. Material and Methods: Fifty consecutive patients with suspected internal carotid artery stenosis underwent CE-MRA and digital subtraction angiography. CE-MRA was performed on a 1.5-T superconducting scanner with the CareBolus technique. CareBolus combines a nearly real-time 2D-FLASH (fast low angle shot) sequence for fluoroscopic triggering and a high-resolution 3D-FLASH with elliptical centric view order for the angiographic pulse sequence (6.0/2.16 ms [TR/TE], 30° flip angle, 30.98 s acquisition time, 0.88 mm effective (interpolated) partition thickness and a 160×512 matrix). Intra-arterial digital subtraction angiography and CE-MRA studies were evaluated independently by four blinded readers. Internal carotid artery stenoses were graded according to the NASCET criteria. Results: CE-MRA had an accuracy of 92.53%, a sensitivity of 95.64%, and a specificity of 90.39% for the identification of carotid artery stenoses ≥70% (grade 3). Image quality for suppression of stationary tissue and venous contrast was good, but was reduced in five cases due to patient motion. Conclusion: The CareBolus technique is a useful non-invasive method for high-resolution imaging of the supra-aortic vessels because of its easy application and high sensitivity and specificity. Limitations can occur in non-compliant patients due to motion artifacts during the measurement time.  相似文献   

9.

Introduction

Ostium of vertebral artery (VA) is a common site of pseudostenosis on contrast-enhanced MR angiography (CE-MRA). The purpose of this study was to determine the diagnostic accuracy of CE-MRA at 3 T in the evaluation of ostial stenosis of VA and to find associated coincidental stenoses using logistic regression analysis.

Methods

One hundred and thirty-five VA ostial regions from 72 patients who received CE-MRA of neck vessels, intracranial time of flight (TOF) MRA, and digital subtraction angiography (DSA) were retrospectively reviewed. The sensitivity and specificity of the CE-MRA in detection of ostial stenosis were calculated with reference standard of DSA. Ostial stenosis on MRA was correlated with coincidental lesions in intracranial and cervical arteries by logistic regression analysis.

Results

The sensitivity and specificity of the CE-MRA were 100% and 80.4% for detection of significant stenosis. In case of significant stenoses, CE-MRA showed a tendency of overestimation with a false-positive rate of 52.5%. Logistic regression analysis showed that the stenoses of middle cerebral artery (MCA) on TOF MRA was associated with significant stenoses of VA ostia (OR?=?5.84, 95% confidence intervals 1.41–24.17).

Conclusion

CE-MRA is sensitive in detection of VA ostial stenosis although it has high false-positive rate. True positive ostial stenosis should be considered in cases of coincidental stenoses of MCA on TOF MRA.  相似文献   

10.
Purpose: To examine the value of cutting-balloon percutaneous transluminal angioplasty (PTA) for hemodialysis access with residual stenosis after conventional balloon PTA.

Material and Methods: Angioplasty with conventional balloons was performed on 48 hemodialysis access stenoses in 28 patients. If the balloon waist still remained at the rated burst pressure, the balloon was reinflated up to three times. Fifteen of 48 stenoses had residual stenoses of more than 30% after conventional balloon PTA. In these 15 stenoses, additional cutting-balloon PTA was performed.

Results: The mean residual percent diameter stenoses before and after conventional balloon PTA were 77.6±3.4% and 48.6±8.5%, respectively. Additional cutting-balloon PTA decreased the mean residual percent diameter to 27.9±10.0%, and the cutting balloon was completely inflated without complication. In 12 patients, the 6-month primary patency rate (±SE) was 90.0% (9.5), and the 1-year primary patency rate (±SE) was 25.0% (14.8).

Conclusion: Additional cutting-balloon PTA was found useful for reducing residual stenosis.  相似文献   

11.
Purpose: To assess the diagnostic accuracy of multi-slice computed tomography (MSCT) angiography compared to digital subtraction angiography (DSA) in detecting residual or recurrent aneurysms in patients undergoing aneurysm clipping surgery.

Material and Methods: Eight patients with nine aneurysms who had both MSCTA and DSA were included in the study. Two independent experienced neuroradiologists evaluated the examinations.

Results: Accuracy, sensitivity, and specificity of detecting residual or recurrent aneurysms on MSCTA were 0.80, 0.60, and 1.00, respectively. Positive and negative predictive values were 1.00 and 0.71, respectively.

Conclusion: MSCTA is a promising technique for evaluating residual or recurrent aneurysms in patients undergoing surgical treatment of aneurysm with titanium clips.  相似文献   

12.
Purpose: To assess the clinical value of three-dimensional coronary MR angiography (CMRA) in the detection of significant coronary artery stenosis using conventional X-ray angiography as the standard reference.

Material and Methods: Sixty-nine patients underwent X-ray coronary angiography and CMRA because of suspected or previously diagnosed coronary artery disease. MRI was performed with a 1.5-T whole body imaging system using ECG-triggered 3D gradient echo sequence with retrospective navigator echo respiratory gating and fat suppression.

Results: A total of 276 coronary artery segments were analyzed. The X-ray coronary angiography was normal in 22 patients. Significant proximal stenoses (exceeding 50%) or occlusions were present in 102 coronary artery segments. In all, 120 stenoses or occlusions were identified in CMRA. Sixteen percent of the coronary artery segments had to be excluded because of poor image quality. The overall sensitivity and specificity for MRA for identification of significant stenosis were 75% and 62%, respectively. CMRA correctly detected 89% of patients with at least one vessel disease, but 6 patients with coronary artery disease would have been missed.

Conclusions: Because of the high data exclusion and false- negative case rate, CMRA with retrospective navigator echo triggering is at present not suitable as a clinical screening method in coronary artery disease.  相似文献   

13.
We evaluated the feasibility of MR angiography for hemodialysis fistula. Eleven patients with suspected stenosis or occlusion of an autogenous hemodialysis fistula in the forearm underwent MRA. MRA was obtained using both the 3D-PC method and 3D gadolinium contrast-enhanced (CE) method with a knee coil. The two methods were compared with DSA in seven patients. CE-MRA clearly demonstrated the entire dialysis fistula. However, signals of the stenotic area are effaced in PC-MRA. The diameter of the vessels evaluated in the CE-MRA was well correlated with angiography. CE-MRA demonstrated smaller collateral vessels more clearly than PC-MRA. CE-MRA provided useful information before the PTA procedure.  相似文献   

14.
Purpose: To evaluate the accuracy of magnetic resonance angiography (MRA) for preoperative assessment of hepatic vascular anatomy in liver donors before living related liver transplantation.

Material and Methods: A total of 55 consecutive living liver donors (mean age 42 years, range 18-68 years) underwent multiphase contrast-enhanced MRA of the hepatic vessels. Two readers categorized vessel visualization on a five-point scale and recorded vascular anatomy or variations thereof for the arterial, portal venous and venous systems. All 55 living liver donors subsequently underwent right hemihepatectomy for hemiliver donation, and preoperative MRA results were correlated with surgical findings.

Results: Overall vessel visualization assessment demonstrated good or very good ratings for the majority of patients. For hepatic arteries, the mean score was 4.4±0.8 (mean±standard deviation), and for the portal venous and venous systems it was 4.6±0.7 and 4.3±0.8, respectively. Among all 55 donors, 16 (29%) demonstrated accessory or replaced hepatic arteries, and seven (13%) and 20 (36%) donors had surgically relevant portal vein (trifurcation or early right posterolateral branching types) and hepatic vein variations, respectively. Correlation coefficients between MRA and surgery were 0.94, 1.00 and 0.91 for hepatic arteries, portal veins and hepatic veins, respectively.

Conclusion: In the preoperative evaluation before living related liver donation, contrast-enhanced MR angiography was a highly accurate, noninvasive tool for visualizing the hepatic vasculature and variations thereof in liver donor candidates.  相似文献   

15.
PURPOSE: To compare high resolution contrast-enhanced MR angiography (MRA) and digital subtraction angiography (DSA) in the assessment of supraaortic vessel stenosis. METHODS: 14 patients with suspicion of cerebrovascular disease or upper limb ischemia underwent selective DSA and high resolution contrast enhanced MRA employing a new Panoramic-Array coil. Stenosis assessment in comparison to DSA followed NASCET criteria. Additionally signal-/noise ratios (SNR) were evaluated to assess contrast enhancement. RESULTS: Diagnostic image quality was achieved in all patients. Sensitivity and specificity for assessing high-grade stenosis of the supraaortic vessels were 100% and 96% respectively. In the assessment of high-grade common or internal carotid artery stenosis sensitivity and specificity was 100%. CONCLUSION: High resolution contrast enhanced supraaortic MRA combined with new coil systems allow for a reliable assessment of stenoses along the whole vessel course including the aortic arch. Previous stent procedures limit its use in postinterventional follow-up.  相似文献   

16.
Purpose: To evaluate the ability of multi-detector row computed tomography angiography (CTA) in detecting hepatic artery complications in the follow-up of liver transplant patients, performing volume-rendering as reconstruction technique.

Material and Methods: The anatomy of hepatic artery was studied in 27 liver transplant recipients with a four-row CT scanner using the following parameters: collimation, 1 mm; slice width, 1 mm; table feed, 6-8 mm/s; spiral reconstruction time, 0.5 s; reconstruction interval, 0.5 mm; mAs, 160; kVp, 120. Before the study, the patients received 1000 ml of water as oral contrast agent to produce negative contrast in the stomach and the small bowel. A non-ionic contrast medium was infused intravenously at a rate of 5 ml/s with a bolus tracking system. Volume-rendering of hepatic artery was performed with the 3D Virtuoso software.

Results: The celiac trunk, the hepatic artery, and the right and left hepatic arteries were successfully displayed in high detail in all patients. Side branches, including small collaterals, and hepatic artery anastomosis could also be readily visualized. Volume-rendered CTA detected six hepatic artery stenoses, two hepatic artery thromboses, and two intrahepatic pseudoaneurysms. In two cases, CT detected hepatic artery stenosis with a diameter reduction of less than 50%, while digital subtraction angiography showed a normal artery.

Conclusion: Volume-rendered multi-detector CTA is a promising non-invasive technique, since it allows images of high quality to be generated with excellent anatomical visualization of the hepatic artery and its complications in liver transplant recipients.  相似文献   

17.
目的探讨三维对比增强磁共振血管成像(3D CE-MRA)在颈部动脉血管狭窄诊断中的临床应用价值。方法对23例临床拟诊颈部动脉血管狭窄行数字减影血管造影(DSA)的患者行颈部3D CE-MRA。将两种方法检查结果进行相关性比较。结果 23例患者共230个节段血管,3D CE-MRA显示了227个节段,共诊断出74处(32.6%)狭窄,其中28处轻度狭窄,22处中度狭窄,20处重度狭窄,4处闭塞;DSA共显示了230个节段的血管,共诊断出69处(30.4%)血管狭窄,其中24处轻度狭窄,23处中度狭窄,19处重度狭窄,3处闭塞。与DSA相比,3DCE-MRA对颈部动脉轻度、中度、重度狭窄及动脉闭塞的显示敏感性均为100%,特异性分别为85.71%、90.91%、90%和75%,两种检查方法对颈部动脉狭窄程度的判断有良好的一致性(κ=0.921,P=0.000)。结论 3.0T 3DCE-MRA能够可靠的评价颈部动脉狭窄性病变,基本可以替代DSA检查。  相似文献   

18.
Background: The introduction of multidetector-row computed tomography (MDCT) has revolutionized the initial management of multiply injured patients. This technology has the potential to improve the imaging of traumatic vascular injuries.

Purpose: To evaluate the quality of multidetector-row computed tomography angiography (MDCTA) of the carotid arteries in the setting of a routine whole-body trauma scan.

Material and Methods: 87 trauma patients underwent a routine whole-body CT scan in a 16-detector-row scanner including an MDCTA with a reconstructed axial slice thickness of 3 mm. Images were reviewed by three experienced radiologists with emphasis on image quality. Contrast density, severity, and origin of artifacts and the occurrence of vessel lesions were assessed for different vessel segments.

Results: 3642 separate vessel segments were evaluated. Contrast density was rated good or sufficient for diagnosis in 99.8%. A total of 67.3% of vessel segments were free of artifacts, while 27.9% of vessel segments showed minor artifacts not impairing diagnostic evaluation. Clinically relevant artifacts obscuring a vessel segment occurred in 4.7% and were mostly caused by dental hardware. Four dissections of the internal carotid artery were diagnosed by all three radiologists.

Conclusion: As a rapid screening test for blunt carotid artery injury, integration of MDCTA in the routine imaging workup of trauma patients utilizing a whole-body CT trauma scan is possible and practicable. Image quality is mostly sufficient for diagnosis, but impaired in a few cases by artifacts deriving primarily from dental hardware.  相似文献   

19.
Purpose: To report the initial experience of magnetic resonance (MR) digital subtraction angiography (MR-DSA) in the dynamic assessment of the cerebral circulation in acute non-traumatic intracerebral hemorrhage (ICH).

Material and Methods: Twelve patients with acute ICH were investigated within 6 days of the ictus using a dynamic contrast-enhanced 2-D MR angiogram that produces subtracted images with a temporal resolution of 1-2 frame/s. The MR-DSA examinations were assessed for evidence of an intracranial vascular abnormality and were compared with (i) the routine MR sequences, (ii) non-dynamic time-of-flight MR angiography, and (iii) catheter angiogram performed during the same admission.

Results: All 12 MR-DSA examinations were considered to be technically satisfactory. MR-DSA detected an intracranial vascular abnormality in 7 patients (3 arteriovenous malformations, 2 aneurysms, 1 dural arteriovenous fistula, and 1 venous thrombosis). All abnormalities were confirmed by catheter angiography with the exception of one patient with venous sinus thrombosis found on MR imaging that did not undergo catheter angiography. All four arteriovenous shunts were detected by MR-DSA by virtue of early venous filling.

Conclusion: MR-DSA can be performed satisfactorily in the setting of acute ICH and provides an alternative method to catheter angiography for identifying shunting vascular abnormalities such as arteriovenous malformations and fistulae, as well as large aneurysms and venous occlusions. MR-DSA is a contrast-medium-based technique that does not suffer from the T1 shortening effects of acute hemorrhage that can obscure abnormalities on conventional flow-based non-dynamic techniques.  相似文献   

20.
PURPOSE: To compare gadobenate dimeglumine (Gd-BOPTA)-enhanced MR angiography (i.e., contrast-enhanced MRA [CE-MRA]) of the pedal vasculature with selective digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease (PAOD). MATERIALS AND METHODS: A total of 22 patients with PAOD were prospectively examined at 1.5T. For contrast enhancement, 0.1 mmol/kg body weight of Gd-BOPTA were applied. MRA consisted of dynamic imaging with acquisition of six consecutive data sets. Acquisition time for each data set was 24 seconds, voxel size was 1.0 x 1.0 x 1.3 mm(3). A total of 20 out of 22 patient underwent selective DSA, two patients fine-needle DSA. DSA and MRA were performed within seven days. Image analysis was independently done by two observers with assessment of overall image quality, motion artifacts, detection of patent vessel segments of the distal calf and pedal vessels, and the number of patent metatarsal arteries. After four weeks, a consensus reading of DSA images was done. A second consensus reading of CE-MRA was performed after a further six weeks. RESULTS: Consensus readings of MRA and DSA revealed higher image quality and fewer motion artifacts for MRA (P = 0.021 and P = 0.008, respectively, sign test); interobserver agreement was good (kappa = 0.78) for image quality, and moderate (kappa = 0.46) for motion artifacts. There were no differences between CE-MRA and DSA in detecting patent vessel segments with a high degree of agreement (kappa = 0.89), and interobserver agreement for MRA was substantial (kappa = 0.89). Significantly more vessels were assessed as partially occluded on DSA than on CE-MRA (P = 0.004). There was a good agreement between DSA and CE-MRA for assessment of relevant vessel stenosis (kappa = 0.61); interobserver agreement for MRA was good (kappa = 0.65). CE-MRA detected significantly more patent metatarsal arteries than did DSA (P < 0.001). CONCLUSION: Gd-BOPTA-enhanced MRA is comparable to DSA for assessment of the pedal vasculature, and is able to delineate significantly more patent vessels without segmental occlusions and more metatarsal arteries than selective DSA.  相似文献   