首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of this study was to evaluate the accuracy of quantitative 1-day exercise-rest technetium-99m tetrofosmin tomography in the identification of patients with coronary artery disease (CAD) and in the detection of individual stenosed coronary vessels. Sixty-one patients with suspected CAD who underwent coronary angiography and 13 normal volunteers were studied. All patients were submitted to two i.v. injections of99mTc-tetrofosmin, one at peak exercise (370 MBq) and the other (1110 MBq) at rest 3 h after exercise (images 15–30 min after injection for both studies). All patients with CAD (0% luminal stenosis) (n=50) had an abnormal99mTc-tetrofosmin tomogram. Only one patient without significant coronary narrowing showed abnormal findings. Overall sensitivity, specificity and diagnostic accuracy in the detection of individual stenosed vessels were 77%, 93% and 85%, respectively. Sensitivity and diagnostic accuracy in the identification of individuals stenosed coronary vessels were significantly higher (P<0.05) in patients with single-vessel disease (n=21) than in those with multivessel disease (n=29). Sensitivity, specificity and accuracy for detecting individual diseased vessels were similar in patients without previous myocardial infarction (n=26) and in those with previous myocardial infarction (n=35). In myocardial territories related to non-infarcted areas (n=128), sensitivity and specificity in the detection of stenosed vessels were 70% and 95%, respectively. In infarcted areas (n=55), sensitivity and specificity in the detection of stenosed vessels were 85% (P=NS vs non-infarcted areas) and 75% (P<0.05 vs non-infarcted areas), respectively. Finally, sensitivity was significantly lower (P<0.05) in vascular territories supplied by vessels with moderate stenosis (50%–75%) than in those supplied by vessels with severe stenosis (>75%). The results of this study demonstrate that quantitative 1-day exercise-rest99mTc-tetrofosmin single-photon emission tomographic imaging is a suitable and accurate technique to identify patients with CAD and to detect individual stenosed coronary vessels.  相似文献   

2.
A comparison was performed between technetium-99m tetrofosmin myocardial perfusion tomography at baseline and after nitrate administration, using a 2-day protocol, and rest-reinjection thallium-201 single-photon emission tomography (SPET) studies in order to assess whether nitrates enhance the detection of viable myocardium with99mTc-tetrofosmin. Fifteen patients with coronary artery disease, previous myocardial infarction and a left ventricular ejection fraction <40% underwent201T1 rest-injection and99mTc-tetrofosmin. baseline-postnitroglycerin (0.4 mg sublingually) SPET studies, within 48 h. Tomograms based on the three spatial planes were divided into 15 segments and regional tracer uptake was quantitatively analysed. Viability was defined as presence of tracer uptake >50% of peak activity on baseline studies or after reversibility. The percentage of peak activity of99mTc-tetrofosmin at baseline correlated with that of 201T1 (r=0.82,P <0.001). On baseline99mTc-tetrofosmin studies, 73 of the 225 segments that were analysed had <50% of peal. activity. Fifteen percent of these segments showed reversibility after nitrate administration, with an increase in99mTc-tetrofosmin uptake from 40%±9% to 57%±9% of peak activity (P=0.003). All reversible segments after nitrate administration had viability criteria on201Tl studies, but 20 segments that were non-viable on99mTc-tetrofosmin. studies were viable on201Tl studies. Using a threshold value of >40% of peak activity, only seven segments remained non-viable on99mTc-tetrofosmin studies. Overall agreement between99mTc-tetrofosmin with nitrates and201Tl-reinjection regarding the presence of myocardial viability was 90%. Detection of myocardial viability with99mTc-tetrofosmin. was enhanced after nitrate administration, correlating with viability criteria observed on thallium studies.  相似文献   

3.
To date several studies have evaluated the accuracy of thallium-201 myocardial scan in risk stratification of coronary artery disease (CAD), while reports using technetium-99m methoxyisobutylisonitrile (MIBI), a tracer particularly suited to single-photon emission tomographic (SPET) imaging, are lacking. To rectify this omission, a prospective study was started in 1988 and at present 176 consecutive, and thus unselected, patients have been enrolled. All of them have been submitted to stress-rest MIBI SPET for the diagnosis or evaluation of CAD; 147 patients (121 males and 26 females, aged 53±9 years) have completed a surveillance period of at least 36 months following the scintigraphic study (range 36–60 months, mean 43). Sixty-one patients had a documented previous myocardial infarction. The mean pretest likelihood of CAD was 44% in the patients without prior infarction. The main anamnestic, clinical, EKG and scintigraphic findings were evaluated and statistically correlated with the incidence of ensuing cardiac events using both univariate (chi-square test) and multivariate analysis (logistic regression model). Twenty-nine patients suffered from a cardiac event during the follow-up period (i.e. three cardiac deaths, six myocardial infarctions and 20 cases of unstable angina). Statistical multivariate analysis identified MIBI scan as the only highly significant and independent prognostic predictor [P=0.006, relative risk (RR)=17.62]. In detail, the most important scintigraphic parameters were the presence of a reversible defect (P=0.0089, RR=5.11) and the extension of the stress perfusion defect (P=0.0255, RR=3.27). The presence of typical angina proved to be a slightly significant predictor (P=0.051, RR=2.45), while no other examined parameter showed a significant correlation with a bad prognosis. In conclusion, MIBI SPET can be considered a useful tool in the risk stratification of CAD patients. The presence of a reversible perfusion defect or an extensive defect appears responsible for a clear increase in the probability of subsequent cardiac events, thus indicating a more aggressive therapeutic approach to be appropriate.This work was presented in part at the 6th World Congress of the World Federation of Nuclear Medicine and Biology in Sydney, Australia (28–30 October 1994).  相似文献   

4.
The aim of this study was to compare technetium-99m labelled tetrofosmin and sestamibi myocardial perfusion single-photon emission tomography (SPET) with one common sestamibi reference file for bull's eye imaging, with quantitation of the extent and severity of perfusion defects. Twenty patients suspected or known to have coronary artery disease participated in the study. Patients first underwent routine sestamibi myocardial SPET over 2 days, receiving doses of 400–600 MBq at stress and 600–800 MBq at rest. Then within the same week a 1-day tetrofosmin myocardial SPET study was performed, with a dose of 300 MBq at stress, followed 2.5 h later by a dose of 750 MBq at rest. Bull's eye images were generated for visual evaluation. Black-out defects according to the Cequal software analysis were only recorded if they comprised more than 10 pixels in men and 20 in women. According to the Cequal program, extent score and severity scores were expressed as number of pixels and deviations below reference limits. Five patients had normal myocardial SPET imaging with both radiotracers, while 15 had reversible, irreversible or partially reversible defects. The concordance of the results was high. The only two significant differences were that one patient had a reversible defect which appeared to be located in different myocardial regions (LAD vs RCA), and another patient had a defect that was partially reversible with sestamibi but irreversible with tetrofosmin. The results showed very high correlation coefficients for the extent and severity scores (linear correlation coefficient values of 0.99 and 0.94, respectively). In conclusion, it appears that changing between sestamibi and tetrofosmin has little influence on the interpretation of bull's eye images from the data file of a common reference population using one of the tracers.  相似文献   

5.
Technetium-99m sestamibi and 99mTc-tetrofosmin are at present the preferred tracers for simultaneous assessment of myocardial perfusion and function by gated single-photon emission tomography (SPET). The aim of this work was to compare sestamibi and tetrofosmin myocardial uptake 1 h after stress injection. Consecutive unselected patients were studied either with sestamibi or with tetrofosmin on a random basis, until at least 100 patients had been enrolled for each gender and tracer. Stress was obtained by dipyridamole or exercise or combined dipyridamole + exercise; in the latter cases, exercise was sustained for at least 1.5 min after tracer injection. Injected activity was similarly adjusted to body weight. For each patient, imaging began 60–75 min after injection. All SPET projections were summed; due to the acquisition technology (”roving zoom”, i.e. a mobile zoom), the heart always appeared at the centre of the frame in all projections and in the sum image. Thus minimal lung background contamination could be assumed in an elliptic region of interest placed over the heart on the sum image. Three indexes were analysed: total myocardial counts (Sum), mean myocardial pixel (Mean) and maximum myocardial pixel (Max). Four patient groups were analysed: males with sestamibi or tetrofosmin (MS: n = 189 and MT: n = 157), females with sestamibi or tetrofosmin (FS: n = 101 and FT: n = 104). MS and MT groups were comparable for physical variables, maximum heart rate and stress type, as were the FS and FT groups. Sum, Mean and Max were significantly higher with sestamibi (P = 0.0001 by ANOVA). Comparing MS vs MT and FS vs FT, mean values ± SD were as follows: for Sum (kcounts) 750±184 vs 652±166, and 707±202 vs 594±189; for Mean (counts) 4517±1171 vs 4107±898, and 4908±1119 vs 4144±1025; and for Max (counts) 6471±1654 vs 5794±1312, and 7318±1886 vs 6152±1684. The mean gain with sestamibi was +15%, +10% and +12% in males, and +19%, +18% and +19% in females. Similar differences were found within each stress type subgroup. No gender-specific effect was found for Mean, so the overall mean gain was calculated for Mean: +13% for sestamibi vs tetrofosmin. These findings are consistent with other published smaller sample series. Possible differences between tracers with regard to residual activity in syringes were ruled out by an additional experiment. In summary, we found significantly higher myocardial counts with sestamibi than with tetrofosmin, in males as well as in females. Received 10 February and in revised form 27 July 1998  相似文献   

6.
Myocardial single photon emission tomography (SPET) using technetium-99m teboroxime (teboroxime) was studied and the results compared with those of thallium-201(thallium) SPET and coronary arteriography in 19 patients. Resting teboroxime SPET was performed initially. Two hours later, exercise teboroxime SPET was performed. Exercise ergometer tests for both teboroxime and thallium were carried out in a supine position. The levels of exercise achieved for both tests were similar. Agreement for the identification of myocardial segments between thallium SPET and teboroxime SPET was 147/171(86%) (NS). When a significant stenosis was defined as 75% or 50%, agreement between two radiopharmaceuticals for the detection of diseased vessels was 89% (NS, = 0.601) or 88% (NS, = 0.713), respectively. In only 2/19 cases were inferior and posterior segments (3/171) difficult to interpret in teboroxime SPET due to hepatic activity. Thus, teboroxime SPET with a short data acquisition time resulted in a rapid completion for each study and had a good correlation with thallium SPET. Offprint requests to: M. Oshima, M.D., Ph.D. Department of Radiology Nagoya First Red Cross Hospital  相似文献   

7.
Nine lesions in eight patients with hepatocellular carcinoma (HCC) were studied using single-photon emission tomography (SPET) and technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) to evaluate the pattern of uptake of 99mTc-MIBI in the lesions and the relation between the uptake pattern and the histopathology of HCC. All the lesions were diagnosed as HCC by percutaneous needle biopsy. Four of the nine lesions showed positive uptake of 99mTc-MIBI, while the other five showed negative uptake. All of the lesions which showed positive uptake were of the compact type. Of the five lesions that showed negative uptake, four were of the trabecular type while one was of the compact type. These results suggest that the patterns of 99mTc-MIBI accumulation in HCC are divided into positive and negative types and that these uptake patterns are associated with the tissue structure of HCC. Received 10 August and in revised form 15 August 1997  相似文献   

8.
Single-photon emission tomography (SPET) with technetium-99m sestamibi (MIBI) was carried out in 61 adult patients with supratentorial expanding brain lesions. Thirty-one patients had pathologically proven malignant glioma. Ten patients had pathologically proven low-grade glioma, while another 12 patients had a clinical diagnosis of low-grade glioma. The other eight patients had a variety of lesions including radiation necrosis (3), abscess (2), ischaemic stroke (2) and primary brain lymphoma (1). SPET was performed 15 min after administration of 740–930 MBq MIBI and transverse, sagittal and coronal views were reconstructed. Using computed tomography or magnetic resonance imaging guidance, a MIBI uptake index was computed as the ratio of counts in the lesion to counts in the contralateral homologous region. In high-grade gliomas, the MIBI index ranged from 1.9 to 6.6 (mean 3.6 ± 1.4) whereas it ranged from 0.8 to 1.7 (1.1 ± 0.2) in the pathologically proven low-grade group (P < 0.01). No significant difference was found between the two low-grade groups (1.1 ± 0.2 vs 1.1 ± 0.2). No overlap was found between high-grade and low-grade glioma index values. Patients with suspected radiation necrosis, cerebral abscess or ischaemic stroke did not demonstrate high MIBI uptake (0.9–2.2), whereas one patient with brain lymphoma did (3.9). This study suggests that MIBI SPET imaging is of value in distinguishing low-from high-grade supratentorial gliomas in adults. Permanent address: This paper was presented in part at the EANM Congress in Lausanne  相似文献   

9.
The value of technetium-99m methoxy-isobutylisonitrile (MIBI) single-photon emission tomography (SPET) of the chest in differentiating lung carcinomas of various histological types and benign lesions was assessed in 54 patients (47 males and 7 females aged 19–77 years) with single solid lung masses. Chest radiography had indicated that 46 of the lesions were malignant (8 small cell carcinomas, 14 epidermoid carcinomas, 18 adenocarcinomas and 6 undifferentiated large cell carcinomas) and eight, benign. Ten, volunteers who also agreed to undergo 99mTc-MIBI SPET of the chest served as a control group. The results showed that only 65% (30/46) of the lung malignancies were detected by 99mTc-MIBI SPECT, including 63% (5/8) of the small cell carcinomas, 64% (9/14) of the epidermoid carcinomas, 72% (13/18) of the adenocarcinomas and 50% (3/6) of the undifferentiated large cell carcinomas. However, 75% (6/8) of the benign lesions were also detected. The diagnostic sensitivity, specificity and accuracy in differentiating malignant and benign lesions were 65%, 57% and 70%, respectively. We conclude that 99mTc-MIBI is of limited use in the differentiation of single solid lesions in the lungs. Correspondence to: Chia-Hung Kao  相似文献   

10.
We compared technetium-99m methoxyisobutylisonitrile (MIBI) myocardial perfusion single-photon emission tomography (SPET) (MPS) and electron beam computed tomography (EBCT) in order to assess their respective value in the detection of coronary artery disease (CAD).99mTc-MIBI SPET (stress-resting) and EBCT studies were performed in 51 patients with suspected CAD who underwent coronary angiography (CAG). CAG showed that of the 51 patients, 36 had coronary stenosis 50% while 15 had normal results. A moderate positive rank correlation was found between coronary calcification detected by EBCT and MPS score (r s=0.5283,P<0.01). The concordance between EBCT and MPS for the evaluation of CAD was 72.5% (37/51). The sensitivity of EBCT in detecting CAD in 51 patients was comparable to that of MPS (81% vs 94%, NS). However, the accuracy of EBCT was lower than that of MPS (78% vs 94%,P<0.025). As regards the detection of individual coronary artery disease, there was no significant difference in sensitivity between EBCT and MPS (65% vs 75%, NS); however, the specificity and accuracy of EBCT were lower than those of MPS (specificity: 77% vs 95%,P<0.005; accuracy 71% vs 85%,P<0.005). The sensitivity, specificity and accuracy of MPS in detecting single-vessel disease were higher than those of EBCT (sensitivity: 86% vs 42%,P<0.025; specificity: 96% vs 70%,P<0.025; accuracy: 93% vs 61%,P<0.005). However, no significant differences in the sensitivity, specificity and accuracy of MPS and EBCT were found in respect of multivessel disease. In conclusion:99mTc-MIBI myocardial perfusion SPET and EBCT provide different information in the assessment of CAD. The sensitivity of EBCT for the detection of CAD is comparable with that of MPS; however, the specificity and accuracy of EBCT are lower than those of MPS. More reliable results will be obtained if both myocardial perfusion SPET and EBCT are performed.  相似文献   

11.
Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500–600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22°C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22°C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of 99mTc-tetrofosmin and 99mTc-furifosmin with material used in our setting does not approach relevant amounts. Received 6 May and in revised form 19 May 1998  相似文献   

12.
The objective of this study was to search for regional cerebral blood flow (rCBF) abnormalities in adolescents with initial-stage schizophrenia by means of brain single-photon emission tomography (SPET) using technetium-99m hexamethylpropylene amine oxime (HMPAO). SPET studies were performed on a homogeneous sample of 15 carefully selected adolescents with a recent diagnosis of schizophrenia, and without previous electroconvulsive or antipsychotic drug treatment. Computed tomography (CT) and electro-encephalographic (EEG) studies were performed in all patients. Qualitative and semiquantitative analysis of99mTc-HMPAO SPET studies showed an impaired rCBF in 12 patients (80%). The most common pattern was a decreased uptake of99mTc-HMPAO in the frontal lobes, usually in the left hemisphere. Conventional and quantitative EEG was positive in 12 (80%) and 15 (100%) patients, respectively. CT findings were positive in two patients (13%). There was a high level of concordance between SPET and EEG results and between SPET and clinical features (P>0.05). This study suggests that previously untreated patients in the first stages of schizophrenia present functional abnormalities that are revealed by brain SPET.  相似文献   

13.
The effects of two post-acquisition corrections on the visual and quantitative analysis of technetium-99m hexamethylpropylene amine oxime (HMPAO) single-photon emission tomography (SPET) were determined. The corrections were for: (1) the improper spatial orientation of the patient data sets, and (2) the non-linear uptake of HMPAO across the blood-brain barrier. Reorienting the SPET image data sets removed observers' uncertainty in assessment caused by suspected head tilt; however, it increased their uncertainty due to perceived subtle perfusion deficits. Applying the correction to compensate for the decrease in uptake of HMPAO in high-flow regions resulted in an increase in the number of positive assessments. In a study involving 30 patient studies, intea-observer reliability increased from 62% to 83% (average of two observers) after applying both of the corrections, while inter-observer reliability improved from 62% to 81%. Quantitative methods of analysing the images are also affected by the corrections. In an ROI-based classification scheme, the quantitative assessments of more than one-half of the images are affected by the two corrections. These results need to be considered when comparing both quantitative and visual results from different studies in which the corrections may or may not have been applied.  相似文献   

14.
To test the clinical significance of technetium-99m teboroxime regional myocardial clearance in the detection of coronary artery disease, 25 patients underwent dynamic planar or single-photon emission tomographic (SPET) myocardial imaging with 99mTc-teboroxime after exercise and again 2 h later at rest. All patients underwent both thallium-201 exercise and redistribution SPET and coronary arteriography. The early phases of exercise 99mTc-teboroxime myocardial clearance determined by dynamic planar imaging showed a significant difference between normal and post-stenotic myocardial regions (clearance rate constant k: 0.047±0.005 min' versus 0.034±0.003 min–1, P <0.001). Reflecting this differential clearance between myocardial regions, an early redistribution-like phenomenon was observed in a significant number of myocaridal segments by comparing serially acquired post-exercise 99mTc-teboroxime SPET images. These results indicated that the analysis of 99mTc-teboroxime myocardial clearance was of potential use in the detection of coronary artery disease, yielding additional information to that provided by the tracer distribution analysis. Although the early redistribution-like phenomenon of 99mTc-teboroxime could be the source of underestimation of ischaemia if acquisition of the initial post-exercise image were delayed, it could also prove useful in the early differentiation of ischaemia from scar because when the phenomenon was observed in delayed post-exercise images, the rest study could be omitted under some circumstances.  相似文献   

15.
The aim of this study was to develop a new method for quantifying regional cerebral blood flow (rCBF) with technetium-99m ethyl cysteinate dimer (ECD) and single-photon emission tomography (SPET). Employing a three-compartment model, we introduced a parameter, regional brain fractionation index (BFI), that reflects rCBF values and is obtained by a single SPET scan at optimum time T (min) after tracer injection and the integral of arterial input. By analysing the dynamic SPET and arterial blood sampling data of 15 subjects, including the results of acetazolamide challenges, with the graphical plot method, optimum time T was determined to be approximately 20 min post injection. Regional BFI values of each subject were calculated from the single SPET data at 20 min and arterial input. The relationship between the values of regional BFI and rCBF obtained by xenon-133 inhalation SPET was analysed by approximation with an exponential function, resulting in good agreement (r = 0.907). In the present method, rCBF values were determined from regional BFI values by using the inverse exponential function as a non-linear regression curve. To validate the method, we applied it to six other subjects, in whom acetazolamide challenges were also performed. In comparing rCBF values thus obtained and those obtained by 133Xe inhalation SPET, we found a good correlation (r = 0.901) with an inclination approximating 1 (= 1.02) and without underestimation of rCBF in the high-flow range. Since the present method does not require dynamic planar imaging or dynamic SPET scanning, it can be applied to any type of SPET scanner and is useful in clinical SPET studies. Received 1 August 1998 and in revised form 28 October 1998  相似文献   

16.
Irregular photon attenuation may limit the diagnostic accuracy of myocardial single-photon emission tomography (SPET). The aim of this study was to quantify the potential benefit of attenuation correction by simultaneous emission and transmission imaging for the detection of coronary artery disease (CAD) of vessels supplying the inferoposterior wall segments. In 25 male patients with 50% stenoses of the right coronary artery and/or circumflex artery but without significant narrowing of the left anterior descending artery, stress studies using technetium-99m tetrofosmin (400 MBq) were carried out with and without attenuation correction. A dual-head camera with L-shaped detector positioning was equipped with two scanning gadolinium-153 line sources. Tomograms were reconstructed and quantified using circumferential count rate profiles of myocardial activity (two in each patient). The profiles were compared with the respective normal ranges obtained from a database of 25 male patients with a <10% likelihood of CAD. In patients without CAD, the maximal differences in count density of different wall segments were reduced from 29.0% in non-corrected (NC) studies to 9.5% in attenuation-corrected (AC) studies. In particular, the inferoposterior and septal wall segments were represented by significantly increased relative count densities after attenuation correction. The effects of attenuation correction proved independent of body mass. In patients with CAD, segmental count densities were abnormal in 84% of the NC studies and 100% of the AC studies. In single-vessel disease the stenotic vessel was identified in 66% of cases by NC studies and in 100% by AC studies. In AC studies, the extent and depth of defects exceeded those in NC studies. For the detection of CAD of the right coronary artery, the receiver operating characteristic (ROC) curves relating to the AC studies demonstrated improved discrimination capacity (P<0.05). ROC analysis of CAD detection yielded normalcy rates of 82% (NC) and 94% (AC) for the circumflex artery and 65% (NC) and 97% (AC) for the right coronary artery area at a sensitivity level of 95%. It is concluded that attenuation correction using the above system may enhance the diagnostic accuracy of myocardial SPET when inferoposterior wall segments are to be evaluated.  相似文献   

17.
The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer,99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent diseuse. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were 1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were rot statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC.  相似文献   

18.
We compare thallium-201 rest redistribution and fluorine-18 fluorodeoxyglucose ([18F]FDG) for the assessment of myocardial viability within technetium-99m methoxyisobutylisonitrile (MIBI) perfusion defects in 27 patients with chronic stable coronary artery disease. The following studies were performed: (1) stress99mTc-MIBI, (2) rest99mTc-MIBI, (3)201T1 rest-redistribution single-photon emission tomography, (4) [18F]FDG positron emission tomography. The left ventricle was devided into 11 segments on matched tomographic images. The segment with the highest activity at stress was taken as the reference (activity=100%). Perfusion defects at99mTc-MIBI rest were classified as severe (activity<50%), moderate (activity 50%–60%) or mild (activity 60%–85%). Uptakes of [18F]FDG and rest-redistributed201Tl were recognized as significant if they exceeded 50% of that in the reference segment. Among the 33 segments with severe99mTc-MIBI rest perfusion defects, 21 had significant [18F]FDG and 10 significant rest-redistributed201Tl uptake. As regards the 37 segments with moderate defects, [18F]FDG was present in 29 and201Tl in 31, while of the 134 segments with mild defects, 128 showed [18F]FDG uptake, and 131,201Tl uptake. In conclusion, there is an inverse relationship between the severity of99mTc-MIBI perfusion defects and the uptake of rest-redistributed201Tl and [18F]FDG. Both tracers are adequate markers of viability in mild and moderate defects; in severe defects201Tl might underestimate the presence of viability as assessed by [18F]FDG.  相似文献   

19.
The detection of preserved glucose uptake in hypoperfused dysfunctional myocardium by fluorine-18 deoxyglucose (FDG) positron emission tomography (PET) represents the method of choice in myocardial viability diagnostics. As the technique is not available for the majority of patients due to cost and the limited capacity of the PET centres, it was the aim of the present work to develop and test FDG single-photon emission tomography (SPET) with the means of conventional nuclear medicine. The perfusion marker sestamibi (MIBI) was used together with the metabolic tracer FDG in dual-isotope acquisition. A conventional SPET camera was equipped with a 511-keV collimator and designed to operate with simultaneous four-channel acquisition. In this way, the scatter of 18F into the technetium-99m energy window could be taken into account by a novel method of scatter correction. Thirty patients with regional wall motion abnormalities at rest were investigated. The results of visual wall motion analysis by contrast cine-ventriculography in nine segments/heart were compared with the results of quantitative scintigraphy. The scintigraphic patterns of MIBI and FDG tracer accumulation were defined as normal, matched defects and perfusion-metabolism mismatches. Spatial resolution of the system was satisfactory, with a full width at half maximum (FWHM) of 15.2 mm for 18F and 14.0 mm for 99mTe, as measured by planar imaging in air at 5 cm distance from the collimator. Image quality allowed interpretation in all 30 patients. 88% of segments without relevant wall motion abnormalities presented normal scintigraphic results. Seventy-five akinetic segments showed mismatches in 27%, matched defects in 44% and normal perfusion in 29%. We conclude that FDG-MIBI dual-isotope SPET is technically feasible with the means of conventional nuclear medicine. Thus, the method is potentially available for widespread application in patient care and may represent an alternative to the 201T1 reinjection technique.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号