首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In an attempt to decrease aseptic loosening, total joint components are now being used without cement. Most components are designed to achieve fixation biologically. The radiographic results of 144 primary uncemented total hip arthroplastics and the clinical results of 89 arthroplastics that were performed using a proximally porous-coated titanium alloy femoral stem between November 1983 and June 1989 are reported. On the acetabular side, a threaded component or a hemispherical porous-coated component was used. The patients were followed prospectively for 5 to 9 years postsurgery. During the study period, the threaded acetabular component had a high failure rate. Because it was not possible to determine accurately from which component a particular sign or symptom arose, clinical analysis was restricted to only those hips without a failed or revised cup. Eighty-nine hips in 71 patients with a minimum follow-up period of 5 years were available for clinical review. Radiographic review of the femoral stem was completed on all hips with 5 or more years of radiographic follow-up evaluation, regardless of the status of the acetabular component. One hundred twelve hips in 85 patients were analyzed radiographically. At a latest mean follow-up period of 6.7 years, the mean Iowa hip score was 91.4 ± 8.0 with a 5.4% incidence of thigh pain. Throughout the followup period, the patients with thigh pain had a statistically lower mean Iowa pain subscore when compared with those patients without thigh pain (P = .0001). Endosteal erosion was seen in two hips (1.8%) and longitudinal loss of the medial neck greater than 2 mm was noted in two hips. One femoral stem was revised for aseptic loosening. The clinical results of this femoral stem equal ot exceed the published accounts of other uncemented arthroplasties. The results indicate that the stem is associated with good clinical results, minimal bone loss, and little osteolysis. Continued follow-up evaluation of patients with this femoral stem is necessary to assess the durability of these encouraging results.  相似文献   

2.
We evaluated the clinical and radiographic results of the first consecutive 154 implantations of a cementless, double-tapered straight femoral stem (cementless Spotorno (CLS), Sulzer Orthopedics) in 141 patients under the age of 55 (mean 47 (13-55)) years. After a mean follow-up of 12 (10-15) years, 11 patients (11 hips) had died and 7 (7 hips) could not be located. 5 patients (5 hips) underwent femoral revision-1 for infection, 1 for periprosthetic fracture and 3 for aseptic loosening of the stem. The overall survival rate of the stem was 97% at 12 years (95% confidence limits, 93%-100%), and survival with femoral revision for aseptic loosening as an end point 98 (95-100)%. The survival rate of the acetabular components was 78 (71-85)% after 12 years. The median Harris hip score at follow-up was 84 points. None of the patients had thigh pain. Radiolucent lines in Gruen regions 1 and 7 were present in 21 hips (17%). 2 hips had radiolucent lines in regions 2-6 on anteroposterior (AP) radiographs. No femoral osteolysis was detected. The mid- to long-term survival with this type of femoral component is excellent and compares favorably with cemented stems in this age group. However, the high rate of cup loosening and the low Harris hip scores are a concern in this subgroup of young patients.  相似文献   

3.
We evaluated the clinical and radiographic results of the first consecutive 154 implantations of a cementless, double-tapered straight femoral stem (cementless Spotorno (CLS), Sulzer Orthopedics) in 141 patients under the age of 55 (mean 47 (13–55)) years. After a mean follow-up of 12 (10–15) years, 11 patients (11 hips) had died and 7 (7 hips) could not be located. 5 patients (5 hips) underwent femoral revision—1 for infection, 1 for periprosthetic fracture and 3 for aseptic loosening of the stem. The overall survival rate of the stem was 97% at 12 years (95% confidence limits, 93%–100%), and survival with femoral revision for aseptic loosening as an end point 98 (95–100)%. The survival rate of the acetabular components was 78 (71–85) % after 12 years. The median Harris hip score at follow-up was 84 points. None of the patients had thigh pain. Radiolucent lines in Gruen regions 1 and 7 were present in 21 hips (17%). 2 hips had radiolucent lines in regions 2–6 on anteroposterior (AP) radiographs. No femoral osteolysis was detected.

The mid- to long-term survival with this type of femoral component is excellent and compares favorably with cemented stems in this age group. However, the high rate of cup loosening and the low Harris hip scores are a concern in this subgroup of young patients.  相似文献   

4.
Cementless Spotorno tapered titanium stems   总被引:3,自引:0,他引:3  
We evaluated the clinical and radiographic results of the first consecutive 154 implantations of a cementless, double-tapered straight femoral stem (cementless Spotorno (CLS), Sulzer Orthopedics) in 141 patients under the age of 55 (mean 47 (13-55)) years. After a mean follow-up of 12 (10-15) years, 11 patients (11 hips) had died and 7 (7 hips) could not be located. 5 patients (5 hips) underwent femoral revision—1 for infection, 1 for periprosthetic fracture and 3 for aseptic loosening of the stem. The overall survival rate of the stem was 97% at 12 years (95% confidence limits, 93%-100%), and survival with femoral revision for aseptic loosening as an end point 98 (95-100)%. The survival rate of the acetabular components was 78 (71-85) % after 12 years. The median Harris hip score at follow-up was 84 points. None of the patients had thigh pain. Radiolucent lines in Gruen regions 1 and 7 were present in 21 hips (17%). 2 hips had radiolucent lines in regions 2-6 on anteroposterior (AP) radiographs. No femoral osteolysis was detected.

The mid- to long-term survival with this type of femoral component is excellent and compares favorably with cemented stems in this age group. However, the high rate of cup loosening and the low Harris hip scores are a concern in this subgroup of young patients.  相似文献   

5.
6.
The aim of this study was to assess the midterm results of primary cementless total hip arthroplasty using a tapered stem and alumina bearing couple in active patients. After a minimum of 5 years of follow-up, 78 arthroplasties in 72 patients were reviewed retrospectively. The mean Harris hip score was 94 points, and 2 hips had thigh pain. All components radiographically demonstrated stable fixation by bone ingrowth and mild stress shielding of the proximal femur were noted in 14% of hips. There was no significant osteolysis or aseptic loosening. There was a ceramic head fracture in 1 hip and audible sounds in 2 hips. The results of total hip arthroplasty with a straight, tapered, proximally porous-coated stem and alumina-on-alumina bearing were encouraging for active patients.  相似文献   

7.
The purpose of this study was to compare the intermediate results of total hip arthroplasty with a cemented, collarless, femoral prosthesis design (Exeter, Howmedica, Middlesex, UK and CPT, Zimmer, Warsaw, IN) with those of a cementless, collarless, porous-coated femoral component (PCA, Howmedica). A total of 151 hips in 128 patients were reviewed. In the cemented group, 85 Exeter-CPT prostheses were used in 71 patients with an average follow-up period of 6.5 years. In the uncemented group, 66 PCA prostheses were placed in 57 patients with an average follow-up period of 7 years. Harrington hip scores improved from 50.1 to 80.7 for the PGA group and from 49.5 to 87.3 for the Exeter-CPT group. The patient satisfaction rates were 89 and 96%, respectively. Sixty-eight patients with Exeter or CPT prostheses had excellent function and no significant thigh pain after 2 years. One Exeter stem was revised 10 years after the primary surgery because of localized osteolysis due to cement defect. Two Exeter sockets were revised because of aseptic loosening. In the PCA group, the incidence of thigh pain that persisted beyond 2 years was 39.4%, and there were high incidences of distal cortical hypertrophy (66.6%) and bead loosening (45.5%). Sixteen hips were revised for aseptic stem loosening, uncontrollable thight pain, or stem fracture (1 hip), and seven were revised because of migration and aseptic loosening of the socket. The cementless ingrowth stems failed earlier (around 5 years), whereas the cemented stems continued to perform well past 14 years. In this study, the cemented, collarless, collarless, porous-coated anatomic design at an average follow-up period of 7 years (range, 2–14 years).  相似文献   

8.

Background

Second-generation, metal-on-metal total hip arthroplasty (MoM THA) using a 28-mm head has shown favorable results compared with large head MoM THA. The purpose of this study is to evaluate the long-term outcomes of cementless primary MoM THA with a 28-mm head and the incidence of osteolysis using computed tomography.

Methods

A total of 92 patients (53 men and 39 women) who underwent primary cementless MoM THA (114 hips) with a 28-mm head were enrolled in this study. Their mean age was 46.2 years at the time of surgery. The mean follow-up duration was 20 years. The Harris hip score, presence of thigh or groin pain, radiographic results, presence of peri-implant osteolysis, histologic analysis, and Kaplan-Meier survival curves were evaluated.

Results

The mean preoperative Harris hip score of 50.5 improved to 85.1 at the final follow-up. Eight patients (8 hips) experienced groin pain, but none had thigh pain. Twelve revisions (6.2%) were performed including 10 hips for aseptic loosening with osteolysis and 2 hips for periprosthetic fracture around the stem. At 23 years, 91% of patients were free from revision of the acetabular component due to aseptic loosening and 90.1% were free from revision of both femoral and acetabular components due to any reason. Osteolysis was identified around the cup in 12 cases (10.5%) and around the stem in 7 cases (6.1%).

Conclusion

MoM THA with a 28-mm head showed a relatively low rate of aseptic implant loosening at a mean follow-up of 20 years.  相似文献   

9.
BACKGROUND: Fixation of the femoral component of a total hip arthroplasty without cement has had variable results. While tapered stems appear to have consistently good results, the duration of follow-up in many series has been relatively short. The purpose of this study was to present a longer-term (ten to fifteen-year) follow-up after total hip arthroplasty with insertion of a tapered femoral component without cement. METHODS: Sixty-seven total hip arthroplasties were performed with insertion of a tapered, cobalt-chromium femoral component without cement in fifty-eight patients from 1983 to 1986. Thirteen patients (fifteen hips) died prior to the fifteen-year follow-up examination, and three patients (three hips) were lost to follow-up after ten years, leaving forty-two patients (forty-nine hips) who were followed clinically for a mean of fifteen years. Thirty-seven of the forty-nine hips were followed radiographically for fifteen years, and the remaining twelve were followed for a minimum of ten years. RESULTS: The mean preoperative Charnley score was 3.0 points for pain, 2.7 points for function, and 3.2 points for motion. At the time of the final follow-up, the mean scores were 5.6, 5.6, and 5.2 points, respectively. Although no preoperative Harris hip scores were available, the mean score at the time of the latest follow-up was 92 points (range, 78 to 100 points). There were no revisions because of isolated aseptic loosening of the femoral component (although revision because of aseptic loosening of the acetabular component led to femoral component revision in seven hips). Two femoral components showed radiographic evidence of instability. At fifteen years, the prevalence of thigh pain was 2%. No femoral component that was thought to be stable, with bone ingrowth at two years, lost fixation. CONCLUSIONS: The design features of this cobalt-chromium femoral component (i.e., the collarless, tapered, wedge fit with circumferential porous coating) are thought to be crucial to the achievement of the good-to-excellent results seen in this study.  相似文献   

10.
A reduced femoral offset in total hip replacement has been thought to be disadvantageous. We reviewed the results of 54 consecutive primary total hip replacements in 49 patients (mean age of 68 years) performed between August 1990 and December 1994, with a mean follow-up of 8.8 years (sd 2.1). The mean pre-operative femoral offset for these hips was 41 mm (sd 7.4). All patients received a low-offset Charnley stem and a polyethylene cup inserted by a single surgeon. At their latest follow-up, surviving patients had a significant improvement in the performance of their hip. Three had undergone revision, one each for deep infection, recurrent dislocation and late pain with subluxation. No hips had been revised, or were at risk of revision, for aseptic loosening. The mean annual linear rate of wear was 0.2 mm (sd 0.08) for the whole group. There was no correlation between the pre-operative femoral offset and the post-operative rate of wear. Our survivorship estimate was 91% when revision for any reason was taken as an end-point, but 100% if aseptic loosening was considered as the end-point. Our study demonstrates that a low-offset femoral stem can produce good, medium-term results.  相似文献   

11.
BACKGROUND: Second-generation metal-on-metal total hip replacements were introduced in the early 1990s with the aim of eliminating polyethylene wear and the resulting complications of osteolysis and aseptic loosening. The goal of the present study was to evaluate the intermediate-term results in a series of patients who were managed with one of these implants. METHODS: Between 1994 and 2002, we performed 640 total hip replacements in 591 patients with use of a Bicon-Plus cementless threaded cup with a polyethylene liner housing a metal inlay made of Sikomet low-carbon cobalt-chromium-molybdenum alloy that articulates with a Sikomet metal femoral head. Clinical and radiographic evaluation was performed retrospectively at a mean of 7.1 years postoperatively. Histologic analysis was performed on specimens retrieved from seventeen hips that were revised, and wear measurements were made for six hips that were revised. RESULTS: Thirty-four hips (thirty-four patients) were revised because of infection (six hips), aseptic loosening (twenty-three hips), pain without loosening (two hips), or other reasons (three hips). The survival rate of the prosthesis as a whole at ten years, with revision for any reason as the end point, was 0.91 (95% confidence interval, 0.88 to 0.95). The survival rate of the cup was 0.94 (95% confidence interval, 0.90 to 0.97), and that of the stem was 0.96 (95% confidence interval, 0.94 to 0.98). Linear or expansile osteolysis, or both, was observed on the radiographs of sixteen (64%) of the twenty-five hips that were revised because of aseptic loosening and/or pain. Histological analysis of pericapsular tissue was performed for seventeen of the twenty-five hips that were revised because of aseptic loosening and/or pain. Thirteen of these seventeen hips demonstrated a hypersensitivity-like reaction with aseptic inflammatory changes accompanied by moderate to extensive diffuse and perivascular infiltration of lymphocytes. In the six retrieved specimens that were subjected to wear analysis, the main wear mode was abrasive wear. The mean cumulative linear wear for the bearing was 31.3 microm, and the mean annual wear rate was 6.3 microm/yr. The mean clearance was 87.6 microm. CONCLUSIONS: After a mean duration of follow-up of seven years, aseptic loosening was the major reason for failure of Sikomet metal-on-metal prostheses. The histological findings and the prevalence of osteolysis suggest the possibility of a hypersensitivity-like immunological response to wear particles.  相似文献   

12.
We asked whether total hip arthroplasties (THAs) using alumina-on-highly cross-linked polyethylene bearing would improve functional activity and reduce aseptic loosening, polyethylene wear, and osteolysis. Consecutive primary THAs were performed in 71 patients (73 hips) who were younger than 50 years (mean age, 45.5 years) with femoral head osteonecrosis. There were 48 men (50 hips) and 23 women (23 hips). Osteolysis was evaluated using radiographs and computed tomographic scanning. The average follow-up was 8.5 years (range, 7-9 years). The mean preoperative Harris hip score was 50.6 points, which improved to 96 points at the final follow-up. Preoperative functional activity was improved significantly at the latest follow-up. The mean polyethylene linear penetration was 0.05 ± 0.02 mm/y and no hip had aseptic loosening or osteolysis.  相似文献   

13.
A higher-than-average rate of aseptic loosening has been postulated to be associated with the combination of a titanium stem and bone cement. In this prospective follow-up study we therefore investigated our first consecutive series of 250 implantations of a cemented femoral shaft prosthesis made of titanium alloy (BiCONTACT((R)), Aesculap, Tuttlingen, Germany).Average time of follow-up evaluation was 9.7 years (range 8.7-10.3 years). At follow-up, mean patient age was 81 years; 89 patients with 93 hips have deceased and two could not be located. Follow-up rate was 98.7% for the patients still alive at time of follow-up evaluation. Five patients have been revised, two for infection and one for aseptic loosening of a varus-malaligned stem; two radiologically well-fixed stems had been revised during acetabular revision. Survival estimate showed a calculated cumulative survival rate of 97.5% after 11 years [confidence limits: 99.0% (upper) and 94.1% (lower)]. The average Harris hip score at time of follow-up was 82.25 points.Radiologically, signs of loosening could be detected in 3 stems: in one case varus malalignement deteriorated with time and in 2 cases osteolyses developed together with significant polyethylene wear. All 3 patients experienced only mild pain and revision had not been indicated so far. In conclusion, the long-term follow-up results with this cemented titanium femoral component are encouraging and are comparable to other successful cemented femoral components in primary total hip arthroplasty. No increased risk for aseptical loosening was associated to the combination of titanium and cement in this specific stem. Design parameters seem to play an important role in the development of aseptic loosening in cemented titanium stems.  相似文献   

14.
目的:探讨终末期髋关节疾病患者采用 Corail 羟基磷灰石(Hydroxyapatite,HA)全涂层股骨柄假体行全髋关节置换术(Total hip arthroplasty, THA)的中期疗效。方法:回顾性分析2011年 1 0月~2019 年 10月采用 Corail 假体行 THA 治疗 239例(258髋)髋关节终末期疾病患者的病例资料,其中男137例,女102例,年龄38~79岁,平均50.4岁。左髋117例,右髋141例。适应症包括股骨头缺血性坏死145髋(56.2%),髋关节发育不良58髋(22.4%),髋关节骨性关节炎36髋(14.0%),股骨颈骨折11髋(4.3%),类风湿关节炎8髋(3.1%)。采用 Harris 评分、疼痛视觉模拟评分(VAS)及临床并发症评估患者髋关节功能,随访X 片观察假体有无松动、螺钉有无断裂等。结果:所有患者均安全度过围手术期。术后1例患者出现肺部感染伴胸腔积液,术后6例患者术侧大腿出现了不同程度的疼痛,术后5例患者出现假体感染,术后6例患者出现脱位,术后7例患者出现小腿肌间静脉血栓,术后15例患者出现了假体下沉,未出现无菌性松动或神经血管损伤等并发症,无翻修患者,股骨柄存活率为100%。术后239例(258髋)均获随访,随访时间0.5~7年,平均5.8年,末次随访Harris评分(84.84±5.65)分、VAS评分(1.11±0.79),所有的股骨柄都非常稳定,没有透亮线的迹象。结论:Corail HA 全涂层股骨柄假体具有持久的稳定性,术后大腿疼痛发生率较低等优点,中期疗效较好。  相似文献   

15.
This study of proximal porous-coated stems of identical shape, but with two types of stem materials (Ti alloy or Co-Cr alloy), was done to determine the differences, if any, in these stems in the following parameters: clinical and functional outcomes; the prevalence of thigh pain; the stem alignment and the stem-canal fill; cup position; the degree of periprosthetic bone loss; the prevalence of polyethylene liner wear and osteolysis; the incidence of aseptic loosening of acetabular and femoral components; and complication rates. In the Ti alloy group, there were 60 patients (70 hips) followed up for a mean of 6.4 years (range, 5-7 years) with a mean age at surgery of 45.3 years and a mean weight of 65.7 kg. In the Co-Cr alloy group, there were 60 patients (70 hips) followed up for a mean of 6.6 years (range, 5-7 years) with a mean age at surgery of 45.4 years and a mean weight of 66.8 kg. Harris hip scores did not differ and the prevalence of transient pain in the thigh was 5% with both stems. No acetabular or femoral component had aseptic loosening in either group. Loss of bone density in the calcar region was more severe in the Co-Cr group. The mean polyethylene linear wear per year was 0.15 mm (SD, 0.015) in the Ti group and 0.14 mm (SD, 0.013) in the Co-Cr group. No acetabular or femoral osteolysis was seen in any patient. The clinical and radiographic results of this study did not show any significant differences between the Ti and Co-Cr alloy femoral components; however, the Ti alloy femoral component retained greater periprosthetic bone as compared with a Co-Cr alloy femoral component.  相似文献   

16.
BackgroundThe aim of this study is to assess the long-term outcomes of this specific stem in patients younger than 50 years old, with regard to clinical and radiographic outcomes, survivorship, and complication rate.MethodsTwo hundred thirty-nine consecutive series of patients (324 hips) who were younger than 50 years old at the time of surgery were enrolled in the study. Osteonecrosis (50%) and dysplastic hip (34%) were most common diagnoses. Patients were informed to use crutches or walker for 4 weeks to protect the femoral component against rotational stress. The mean follow-up was 15.6 years (range 14-17).ResultsAt the latest follow-up, the mean Harris Hip Score, Western Ontario and McMaster Universities Osteoarthritis Index score, and University of California, Los Angeles activity score were 93 points, 13 points, and 7 points, respectively. Three patients (1.3%) had moderate thigh pain. All of the acetabular components and 321 (99%) femoral stems were solidly fixed at the time of the latest follow-up. Three stems (0.9%) were revised for aseptic loosening. Two hips (0.6%) had a dislocation and 2 hips (0.6%) had a periprosthetic fracture. Ceramic fracture or osteolysis was not found in any hip at the time of the final follow-up. Survival rate of the femoral component was 99.1% (95% confidence interval 94-100) and that of the acetabular component was 100% (95% confidence interval 94-100) at 15.6 years.ConclusionIn this series, THA using an ultra-short metaphyseal-fitting anatomic cementless femoral stem provided excellent long-term clinical and radiographic results in patients younger than 50 years old. Furthermore, our initial theoretical concerns about early aseptic loosening due to the absence of distal stem fixation were not justified.  相似文献   

17.
We performed a prospective study in 108 consecutive patients (116 hips) who were followed for a minimum of 10 years (10-12 years) after primary total hip arthroplasty using an uncemented porous-coated anatomic (PCA) hip prosthesis. The average age of the patients at operation was 48.4 years (range, 19-85 years), and the diagnosis was avascular necrosis of the femoral head in 46 hips, neglected femoral neck fracture in 27, osteoarthrosis secondary to childhood pyogenic arthritis in 24, childhood tuberculous arthritis in 5, and miscellaneous in 14. The average preoperative Harris Hip Score was 55 points, which improved to 87 points at 11 years. Seventy-five hips (65%) were excellent, 11 (9%) were good, and 30 (39%) were poor. The overall rate of revision was 15% (17 of 116 hips). The rate of revision of the femoral component was 11% (13 of 116 hips), and the rate of revision of the acetabular component was 15% (17 of 116 hips). The prevalence of thigh pain was 28% at 11 years. The increase in the incidence of aseptic loosening of the femoral component was found to explain the high incidence of severe thigh pain at 11 years' follow-up. At 11 years, there was femoral osteolysis in 69 hips (59%) and acetabular osteolysis in 65 hips (56%). At 6 years, 20 hips (17%) showed definite wear of the polyethylene liner. At 11 years, 81 hips (70%) showed definite wear of the polyethylene liner. Because the complication rate of the PCA hip prosthesis with respect to loosening, osteolysis, and excessive wear in the polyethylene liner is high, we abandoned the use of this implant.  相似文献   

18.
A ten- to 15-year follow-up of the cementless spotorno stem   总被引:6,自引:0,他引:6  
We followed the first 354 consecutive implantations of a cementless, double-tapered straight femoral stem in 326 patients. Follow-up was at a mean of 12 years (10 to 15). The mean age of the patients was 57 years (13 to 81). At follow-up, 56 patients (59 hips) had died, and eight (eight hips) had been lost to follow-up. Twenty-five hips underwent femoral revision, eight for infection, three for periprosthetic fracture and 14 for aseptic loosening. The overall survival was 92% at 12 years (95% CI 88 to 95). Survival with femoral revision for aseptic loosening as an endpoint was 95% (95% CI 92 to 98). The median Harris hip score at follow-up was 84 points (23 to 100). Radiolucent lines (< 2 mm) in Gruen zones 1 and 7 were present in 38 (16%) and 34 hips (14%), respectively. Radiolucencies in zones 2 to 6 were found in five hips (2%). The results for mid- to long-term survival with this femoral component are encouraging and compare with those achieved in primary cemented total hip arthroplasty. The high rate of loosening of the cup and the high rate of pain are, however, a source of concern.  相似文献   

19.
BACKGROUND: We have been using hybrid total hip arthroplasty (a cementless acetabular component and a cemented stem) in young patients. The purpose of this study was to determine the prevalence of aseptic loosening, polyethylene wear, and osteolysis after the use of this technique. METHODS: We studied a prospective consecutive series of sixty-four primary hybrid total hip replacements in fifty-five patients younger than fifty years old. There were forty-three men and twelve women; the average age at the time of the index operation was 43.4 years. The average duration of follow-up was 9.4 years. We used a cementless acetabular component without screw-holes and a cemented femoral component with a 22-mm head in all hips. Clinical follow-up with use of Harris hip ratings and radiographic follow-up were performed at six weeks; at three, six, and twelve months; and yearly thereafter. The sequential annual linear and volumetric wear rates were measured, and bone-remodeling and osteolysis were assessed. RESULTS: The mean preoperative Harris hip score was 44 points, which increased to 95 points at the time of final follow-up. No hip had aseptic loosening. One hip (2%) was revised because of late infection. The average linear wear (and standard deviation) was 0.96 +/- 0.066 mm, with an average annual rate of 0.096 +/- 0.013 mm. The average volumetric wear was 364.7 +/- 25.2 mm (3), with an average annual rate of 43.4 +/- 3.5 mm (3). Six hips (9%) had an osteolytic lesion of <1 cm in diameter in the calcar femorale (zone 7). CONCLUSIONS: Our results show that a hybrid arthroplasty with a cementless acetabular component and a smooth cemented femoral component (Ra, 0.6 mm) is effective for primary total hip replacement in young patients. Although there was no aseptic loosening and a low prevalence of osteolysis at the latest follow-up evaluation, the high rates of linear and volumetric wear of the polyethylene liner in these young patients remain a concern.  相似文献   

20.
This study aimed to report the outcome of total hip arthroplasty (THA) with a modular femoral component in patients younger than fifty years with osteonecrosis of femoral head. Sixty-four osteonecrotic hips in fifty-five patients were available for clinical and radiographic analyses at minimum follow-up of fifteen-years. The mean Harris hip score improved from 36 points preoperatively to 92.7 points at final follow-up. Sixty-two (95.3%) hips demonstrated stable bone ingrowth. No hips showed loosening or required revision for aseptic loosening. Survivorship with an end point of stem revision for any reason was 93.8% and for aseptic loosening was 100% at 16.8 years. We believe that cementless THA with a modular stem is a promising procedure for young and active patients with osteonecrosis of the femoral head.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号