首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

Changes in spinal alignment and pelvic tilt alter acetabular orientation in predictable ways, which may have implications on stability of total hip arthroplasty (THA). Patients with sagittal spinal deformity represent a subset of patients who may be at particularly high risk of THA instability because of postural compensation for abnormal spinal alignment.

Methods

Using standing stereoradiography, we evaluated the spinopelvic parameters, acetabular cup anteversion, and inclination of 139 THAs in 107 patients with sagittal spinal deformity. Standing images were compared with supine pelvic radiographs to evaluate dynamic changes in acetabular cup position. Dislocation and revision rates were procured through retrospective chart review. The spinal parameters and acetabular cup positions among dislocators were compared with those who did not dislocate.

Results

The rate of THA dislocation in this cohort was 8.0%, with a revision rate of 5.8% for instability. Patients who sustained dislocations had significantly higher spinopelvic tilt, T1-pelvic angle, and mismatch of lumbar lordosis and pelvic incidence. Among all patients, 78% had safe anteversion while supine, which decreased significantly to 58% when standing due to increases in spinopelvic tilt. Among dislocating THA, 80% had safe anteversion, 80% had safe inclination, and 60% had both parameters within the safe zone.

Conclusion

In this cohort, patients with THA and concomitant spinal deformity have a particularly high rate of THA instability despite having an acetabular cup position traditionally thought of as within acceptable alignment. This dislocation risk may be driven by the degree of spinal deformity and by spinopelvic compensation. Surgeons should anticipate potential instability after hip arthroplasty and adjust their surgical plan accordingly.  相似文献   

2.

Background

Acetabular cup placement in total hip arthroplasty (THA) has been recognized as an important factor in operative success, and accurate cup placement has been the impetus for novel medical technologies.

Methods

This article examines the cup placement in 955 THAs using a freehand Direct Anterior Approach on a standard operating table. Acetabular anteversion and inclination were determined using the circle theorem. Measurements were divided into safe zone placement determined by Callanan et al as 5°-25° for anteversion and 30°-45° for inclination, as well as by Lewinnek et al as 5°-25° for anteversion and 30°-50° for inclination. Dislocation rate was determined and correlated to safe zone placement.

Results

Although technology has advanced for cup placement, this investigation shows that a freehand technique demonstrates 0.31% dislocation after THA with an accuracy of 85% for the Lewinnek safe zone and 61% for Callanan, potentially because of the sparing of the posterior hip capsule.

Conclusion

The direct anterior approach to the hip on a regular operating table is safe and reliable. Our results demonstrate improvement in cup positioning compared with other freehand techniques. Surgeon awareness and control of the position of the pelvis within space optimizes acetabular component accuracy and precision without the need for special equipment, such as intraoperative fluoroscopy.  相似文献   

3.

Background

Hip dislocation is one of the most common postoperative complications after total hip arthroplasty (THA). Potential contributors include patient- and surgical-related factors. We performed a retrospective cohort study to identify risk factors for postoperative dislocation in patients receiving THA via the posterolateral approach.

Methods

We assessed 1326 consecutive primary THAs performed between 2010 and 2015. Patient information was documented, and plain radiographic films were used to evaluate cup positioning, hip offset, and hip length change. A multiple logistic regression was used to identify risk factors for dislocation. Follow-up was coordinated by the Danish National Patient Registry.

Results

Age and American Society of Anesthesiologists scores were higher in dislocating THA compared with those in the nondislocating THA. Cup anteversion was less in dislocating THA compared with that in nondislocating THA. Independent risk factors for cup dislocation were increased age, body mass index <25 and >30 kg/m2, and leg shortening of >5 mm.

Conclusion

Surgeons should aim for a shortening of leg length <5 mm to reduce the risk of postoperative dislocation in primary THA. Although anteversion was reduced for dislocating THA, there is likely no universal safe zone for cup positioning. Hip stability is multifactorial, and optimal cup positioning may vary from patient to patient.  相似文献   

4.

Background

In the setting of acetabular deficiency during total hip arthroplasty (THA), the medial protrusio technique (MPT) allows for increased component coverage while avoiding excessive component abduction or elevation of the hip center. The technique involves controlled reaming through the medial acetabular wall while maintaining the continuity of the anterior and posterior columns. The purpose of this study is to analyze the results of the largest reported series to date of primary and revision THAs using the MPT.

Methods

A retrospective review of THAs performed by a single surgeon from July 2004 to July 2010 identified 102 patients who underwent THA necessitating the use of the MPT (primary 86 and revision 16), with at least 2 years follow-up.

Results

This study reports the largest series to date of primary and revision THAs using the MPT for acetabular deficiency. Postoperatively, mean Harris hip score was 86 (range 31-96). There was no correlation with degree of medialization and change in Harris hip score (P = .12). At mean follow-up of 41.1 months (range 24-92 months), there were no intrapelvic structure injuries and no acetabular components required revision. The MPT provided a safe and effective method for addressing acetabular deficiency and avoiding component malposition.

Conclusion

The MPT provided a safe and effective method for addressing acetabular deficiency in this large series of patients. The technique was successful at improving component coverage while maintaining an anatomic hip center and avoiding excessive component abduction. Fixation remained durable with no cases of loosening at final follow-up.  相似文献   

5.

Background

The purpose of the study was to evaluate the implant positions and clinical results of revision total hip arthroplasty (THA) using an imageless navigation with the concept of combined anteversion.

Methods

A total of 40 cementless revision THAs (24 men and 16 women) using an imageless navigation with the concept of combined anteversion were retrospectively evaluated. The concept of combined anteversion was applied in cup positioning based on Widmer's equation (cup anteversion + 0.7 × stem anteversion). The mean follow-up period was 80.7 months. Postoperatively, the inclination of the cup was evaluated on standard anteroposterior view of the radiograph, and the anteversion of the cup and femoral stem was evaluated using computed tomography scan. A cup inclination of 40° ± 10° and combined anteversion of the cup and femoral stem of 37° ± 10° based on Widmer's equation were regarded as the “safe zone.”

Results

The average anteversion of the revised femoral stems was 15.3° ± 2.9° (range, 9.5°-21.5°), whereas that of the remained femoral stems was 17.4° ± 9.7° (range, 4.2°-29.8°). The inclination, anteversion of the cup, and combined anteversion after revision THA were 42.3° ± 3.1° (range, 32.1°-48.2°), 25.0° ± 2.9° (range, 16.9°-29.5°), and 36.1° ± 3.4° (range, 27.2°-42.9°), respectively. Therefore, the position of the implants, relative to the safe zone, showed no outliers after the revision surgery. Neither dislocation nor osteolysis was observed after the surgery.

Conclusion

Favorable results of this study indicate that imageless navigation helps the surgeon in placing the components of revision THA in the safe zone. This study also shows that when this safe zone is consistently obtained, then no postoperative dislocations were observed in these patients over the 6-year follow-up period.  相似文献   

6.

Background

The incidence of hip fractures is growing with the increasing elderly population. Typically, hip fractures are treated with open reduction internal fixation, hemiarthroplasty, or total hip arthroplasty (THA). Failed hip fracture fixation is often salvaged by conversion THA. The total number of conversion THA procedures is also supplemented by its use in treating different failed surgical hip treatments such as acetabular fracture fixation, Perthes disease, slipped capital femoral epiphysis, and developmental dysplasia of the hip. As the incidence of conversion THA rises, it is important to understand the perioperative characteristics of conversion THA. Some studies have demonstrated higher complication rates in conversion THAs than primary THAs, but research distinguishing the 2 groups is still limited.

Methods

Perioperative data for 119 conversion THAs and 251 primary THAs were collected at 2 centers. Multivariable linear regression was performed for continuous variables, multivariable logistic regression for dichotomous variables, and chi-square test for categorical variables.

Results

Outcomes for conversion THAs were significantly different (P < .05) compared to primary THA and had longer hospital length of stay (average 3.8 days for conversion THA, average 2.8 days for primary THA), longer operative time (168 minutes conversion THA, 129 minutes primary THA), greater likelihood of requiring metaphysis/diaphysis fixation, and greater likelihood of requiring revision type implant components.

Conclusion

Our findings suggest that conversion THAs require more resources than primary THAs, as well as advanced revision type components. Based on these findings, conversion THAs should be reclassified to reflect the greater burden borne by treatment centers.  相似文献   

7.

Background

Acetabulum positioning affects dislocation rates, component impingement, bearing surface wear rates, and need for revision surgery. Novel techniques purport to improve the accuracy and precision of acetabular component position, but may have a significant learning curve. Our aim was to assess whether adopting robotic or fluoroscopic techniques improve acetabulum positioning compared to manual total hip arthroplasty (THA) during the learning curve.

Methods

Three types of THAs were compared in this retrospective cohort: (1) the first 100 fluoroscopically guided direct anterior THAs (fluoroscopic anterior [FA]) done by a surgeon learning the anterior approach, (2) the first 100 robotic-assisted posterior THAs done by a surgeon learning robotic-assisted surgery (robotic posterior [RP]), and (3) the last 100 manual posterior (MP) THAs done by each surgeon (200 THAs) before adoption of novel techniques. Component position was measured on plain radiographs. Radiographic measurements were taken by 2 blinded observers. The percentage of hips within the surgeons’ “target zone” (inclination, 30°-50°; anteversion, 10°-30°) was calculated, along with the percentage within the “safe zone” of Lewinnek (inclination, 30°-50°; anteversion, 5°-25°) and Callanan (inclination, 30°-45°; anteversion, 5°-25°). Relative risk (RR) and absolute risk reduction (ARR) were calculated. Variances (square of the standard deviations) were used to describe the variability of cup position.

Results

Seventy-six percentage of MP THAs were within the surgeons’ target zone compared with 84% of FA THAs and 97% of RP THAs. This difference was statistically significant, associated with a RR reduction of 87% (RR, 0.13 [0.04-0.40]; P < .01; ARR, 21%; number needed to treat, 5) for RP compared to MP THAs. Compared to FA THAs, RP THAs were associated with a RR reduction of 81% (RR, 0.19 [0.06-0.62]; P < .01; ARR, 13%; number needed to treat, 8). Variances were lower for acetabulum inclination and anteversion in RP THAs (14.0 and 19.5) as compared to the MP (37.5 and 56.3) and FA (24.5 and 54.6) groups. These differences were statistically significant (P < .01).

Conclusion

Adoption of robotic techniques delivers significant and immediate improvement in the precision of acetabular component positioning during the learning curve. While fluoroscopy has been shown to be beneficial with experience, a learning curve exists before precision improves significantly.  相似文献   

8.

Background

As the prevalence of total hip arthroplasty (THA) expands, so too will complications and patient dissatisfaction. The goal of this study was to identify the common etiologies of malpractice suits and costs of claims after primary and revision THAs.

Methods

Analysis of 115 malpractice claims filed for alleged neglectful primary and revision THA surgeries by orthopedic surgeons insured by a large New York state malpractice carrier between 1983 and 2011.

Results

The incidence of malpractice claims filed for negligent THA procedures is only 0.15% per year in our population. In primary cases, nerve injury (“foot drop”) was the most frequent allegation with 27 claims. Negligent surgery causing dislocation was alleged in 18 and leg length discrepancy in 14. Medical complications were also reported, including 3 thromboembolic events and 6 deaths. In revision cases, dislocation and infection were the most common source of suits. The average indemnity payment was $386,153 and the largest single settlement was $4.1 million for an arterial injury resulting in amputation after a primary hip replacement. The average litigation cost to the insurer was $61,833.

Conclusion

Nerve injury, dislocation, and leg length discrepancy are the most common reason for malpractice after primary THA. Orthopedic surgeons should continue to focus on minimizing the occurrence of these complications while adequately incorporating details about the risks and limitations of surgery into their preoperative education.  相似文献   

9.

Background

Constrained acetabular components have a mechanism to lock in the femoral head. They have been developed to control postoperative dislocation, particularly in revision total hip arthroplasty (THA). Although these components may reduce dislocation, there are durability concerns: with reports of locking mechanism failures and loosening. We wanted to determine the outcome of constrained components in controlling dislocation, and if these components had a higher rate of second revision when compared with standard nonconstrained components.

Methods

Revision THA procedures from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) with a recorded primary procedure and initial diagnosis of osteoarthritis were used to compare constrained and standard nonconstrained components. Kaplan-Meier estimates of survivorship were calculated, and hazard ratios using Cox proportional hazard models were used to compare groups.

Results

There were 9509 THA first-revision procedures and 700 constrained components. Constrained components had a significantly higher revision rate after 3 months when large-head metal-on-metal components were included (hazard ratio = 1.37; P = .005). When large-head metal-on-metal components were excluded, there was no difference in the rate of second revision between the 2 groups. When the analysis was limited to first revision for dislocation, constrained components had a higher second revision rate for further dislocation after 9 months.

Conclusion

Constrained acetabular components had similar second-revision rates when compared with standard nonconstrained components, both for all first-revision reasons and when used to treat dislocation. Although possibly used for the more difficult unstable hips, constrained components had a higher rate of second revision for further dislocation.  相似文献   

10.

Background

Despite the excellent outcomes associated with primary total hip arthroplasty (THA), implant failure and revision continues to burden the healthcare system. THA failure has evolved and displays variability throughout the literature. In order to understand how THAs are failing and how to reduce this burden, it is essential to assess modes of implant failure on a large scale. Thus, we report: (1) etiologies for revision THA; (2) frequencies of revision THA procedures; (3) patient demographics, payor type, and US Census region of revision THA patients; and (4) the length of stay and total costs based on the type of revision THA procedure.

Methods

We queried the National Inpatient Sample database for all revision THA procedures performed between January 1, 2009 and December 31, 2013. This yielded 258,461 revision THAs. Patients specific demographics were identified in order to determine the prevalence of revision procedure performed.

Results

Dislocation was the main indication for revision THA (17.3%), followed by mechanical loosening (16.8%). All-component revision was the most common procedure performed (41.8%). Patients were most commonly white (77.4%), aged 75 years and older (31.6%), and resided in the South US Census region (37.0%). The average length of stay for all procedures was 5.29 days. The mean total charge for revision THA procedures was $77,851.24.

Conclusion

Dislocation and mechanical loosening is the predominant indication for revision THA in the United States. With the frequency of revision THAs projected to double in the next decade, orthopedists must take steps to mitigate this potentially devastating complication.  相似文献   

11.

Background

Dislocation is a leading cause of revision after primary total hip arthroplasty (THA). Although more common in the first few years after the procedure, dislocation can occur at any time. This study investigated the difference in late dislocation in ceramic-on-ceramic (CoC) bearings compared with metal-on-polyethylene and ceramic-on-polyethylene bearings in THA.

Methods

Data were used from the Australian Orthopaedic Association National Joint Replacement Registry, and the cumulative percent revision for dislocation was estimated using the Kaplan-Meier method for the different bearing surfaces. There were 192,275 THAs included in the study with 101,915 metal-on–cross-linked polyethylene (MoXLPE), 30,256 ceramic-on–cross-linked polyethylene (CoXLPE), and 60,104 CoC.

Results

The cumulative percent revision for dislocation at 13 years for MoXLPE, CoXLPE, and CoC groups was 1.2 (95% confidence interval [CI], 1.1-1.3), 1.0 (95% CI, 0.7-1.4), and 0.9 (95% CI, 0.8-1.1), respectively. There was an increased risk of revision for dislocation for MoXLPE compared with CoXLPE and CoC. When stratified for head size, there was no difference in the risk of revision for dislocation between MoXLPE, CoXLPE, and CoC in the 28- and 32-mm head sizes. With a head size of 36 mm, MoXLPE had a higher rate of dislocation compared with other materials.

Conclusion

Bearing surface has little impact on revision for dislocation.  相似文献   

12.

Background

In order to prevent postoperative dislocation due to prosthetic impingement as a result of total hip arthroplasty (THA), the combined anteversion (CA) theory, which combines the anteversion of the femoral stem and the acetabular socket, has been revised in recent years. Particularly, it is necessary to keep CA within the target zone.

Methods

The aim of this study was to investigate whether postoperative CA can be kept within the target zone while using the operative technique which prepares the socket first in cementless THA, by estimating the anteversion of the metaphyseal fit stem or the shorter, tapered wedge stem using preoperative 3-dimensional computerized planning, and by adjusting the anteversion of the socket using a navigation system that considers CA. One hundred fourteen patients (118 hips) were recruited for the study.

Results

Postoperative CA in THA using the metaphyseal fit stem was kept within the target zone for 56 of the 60 hips (93.3%). Using the shorter, tapered wedge stem, 49 of the 58 hips (84.4%) were within the target zone. No postoperative dislocations were observed in any hips.

Conclusion

We found that the metaphyseal fit stem worked better than the shorter, tapered wedge stem in terms of meeting the planned CA. The shorter, tapered wedge stems were flexible in rotation according to the anatomical configuration of the proximal femur. Therefore, the stem could be placed second with the metaphyseal fit stem, but we recommend placing the stem first with the shorter, tapered wedge stem.  相似文献   

13.

Background

Short-term and intermediate-term wear rates for highly cross-linked polyethylene (HCLPE) liners in total hip arthroplasty (THA) are significantly lower than published rates for traditional polyethylene liners. The aim of this study was to report the longest-to-date follow-up of a specific HCLPE liner.

Methods

A series of 35 THAs using a specific HCLPE liner were reviewed. Anteroposterior radiographs were reviewed for femoral head penetration, the presence of femoral and/or acetabular osteolysis, long-term survival, total wear, and wear rates in all patients.

Results

The average patient age at time of surgery was 70 years with an average follow-up of 10 years (118 months; range, 7.2-13.4 years). The mean wear rate in our cohort was 0.07 mm/y. Total wear was 0.71 mm over the study period. No hips showed evidence of osteolysis in any zones. Survivorship at latest follow-up was 100% with all-cause revision as an end point.

Conclusion

The wear rate of HCLPE liners continues to be lower than published wear rates for traditional polyethylene and continues to reaffirm the acceptably low wear rates using HCLPE acetabular liner in primary THA.  相似文献   

14.

Background

This study aims at determining the average long-term result of revision total hip arthroplasty (THA) using the acetabular reinforcement ring with a hook (ARRH) and bone grafting in severe acetabular bony defect. Expected 15-year survival of ARRH in revision THA is included in the study.

Methods

Retrospective review of 48 patients (48 hips) with follow-up duration of average 11.4 years (range, 6.1-21.4 years) was conducted. At each follow-up, Harris hip score was used to assess functional outcome, and radiographic acetabular component osteolysis was measured by DeLee and Charnley classification. Bone defects were assessed preoperatively and intraoperatively using American academy of orthopedic surgeons and Paprosky classification. The common modes of ARRH failures were evaluated. Bone consolidation, presence of heterotopic ossification, and complications such as infection and dislocation were recorded.

Results

The bone defects were varied and included cavitary, segmental, and combined defects without any pelvic discontinuity. Mean Harris hip score improved from 52.6 points preoperatively to 82.0 points postoperatively. Nine acetabular revisions and 3 stem revisions (2 concurrent with acetabular revisions and 1 isolated stem revision) were performed. There were 5 infected cases and 1 patient with recurrent dislocation. The 11.4-year survival of revision THA with ARRH was 71% as the end point for acetabular revision surgery for any reason. The expected 15-year survival of revision THA with ARRH was 60%. The most common failure mode of ARRH was superomedial migration followed by lateral migration.

Conclusion

ARRH combined with bone grafting produces relatively good average long-term clinical results.  相似文献   

15.

Background

The direct anterior approach (DAA) for total hip arthroplasty (THA) is typically performed in the supine position using a specially designed operating room table, which makes this approach more accessible to orthopedic surgeons. We attempted to perform this procedure in the lateral decubitus position on an ordinary operation table to avoid dependence on a special operating room table. There is an obvious absence of literature regarding this subject.

Methods

A total of 248 patients (295 hips) were recruited for primary THAs from July 1, 2014 to December 31, 2014. In total, 126 hips (42.7%) underwent THAs using the DAA in the lateral decubitus position. The technical feasibility and early results were evaluated.

Results

The orientation of the acetabular component was 16.5° ± 4.9° anteversion and 43.3° ± 3.5° abduction. Intraoperative proximal femoral fracture occurred in one hip. The superficial wound complications occurred in 2 hips and the hematoma in one hip while in hospital. The lateral femoral cutaneous nerve injury was noted in 43 hips. The early dislocation occurred in 2 hips. Heterotopic ossification was Brooker class I in 5 hips and class II in 1 hip. No aseptic loosening, postoperative periprosthetic fracture, and deep infection occurred in our series.

Conclusion

The DAA for THA in the lateral decubitus position may be a valuable alternative if the DAA in the supine position is difficult to implement owing to absence of a special operating room table. This technique also seems to provide satisfactory clinical and radiographic outcomes with an acceptable complication in our early follow-up.  相似文献   

16.

Background

The purpose of this study was to identify the long-term durability of the Kerboull-type reinforcement device (KT plate) in acetabular reconstruction for massive bone defects, assessing the remodeling of structural bone grafts.

Methods

This study retrospectively evaluated 106 hips that underwent acetabular reconstruction using a KT plate between November 2000 and December 2010. Thirty-eight primary total hip arthoplasties (THAs) and 68 revised THAs were performed, and the mean duration of clinical follow-up was 8 years (5-14 years). Regarding reconstructing the acetabular bone defects, autografts were used in 37 hips, allografts in 68 hips, and A-W glass ceramics in 2 hips.

Results

One hip exhibited radiological migration and no revision for aseptic loosening. The mean Merle d'Aubigné Clinical Score improved from 7.5 points (4-12 points) preoperatively to 10.9 points (9-18 points) at the last follow-up. The Kaplan–Meier survival rate for radiological migration of primary and revised THAs at 10 years was 100% and 97% (95% confidence interval: 96%-100%), respectively. Bone remodeling was evaluated using the radiological demarcation at the bone-to-bone interface, and an improvement of 100% in primary THAs and 94% in revised THAs was observed.

Conclusion

For massive bone defects, acetabular reconstruction using the KT plate with a structural bone grafting can yield successful results.  相似文献   

17.

Background

Obesity has been described as an independent risk factor for acetabular component malpositioning. The purpose of this study was to determine if this could be overcome by use of fluoroscopic navigation in total hip arthroplasty (THA).

Methods

The first, postoperative, standing, anteroposterior pelvis radiographs from 1599 consecutive patients who underwent fluoroscopic-guided THAs via anterior approach during a six-year period were obtained. We retrospectively reviewed this prospectively collected data. Inclination and anteversion were measured as described by Barrack et al. Intraoperative target ranges for inclination and anteversion angles were 30°-50° and 5°-25°. Patients were divided into 3 cohorts by body mass index, nonobese (<30 kg/m2) obese (between 30 and 40 kg/m2) and morbidly obese (>40 kg/m2), looking for significant differences in acetabular component positioning.

Results

Of the 1599 patients, 1065 were nonobese, 506 obese, and 28 morbidly obese. Overall, average inclination was 37.7° and anteversion was 16.3°. Regarding inclination, 95.0% of cups were positioned in the safe zone, 95.7% for anteversion, and 91.2% for both inclination and anteversion. Analysis of each cohort individually revealed an average inclination of 37.5° in the nonobese, 37.9° in the obese, and 39.9° in the morbidly obese patients. For anteversion, each group's averages were 16.1°, 16.5°, and 16.0°, respectively. There was no significant relationship between a patient's body mass index and cup position for inclination (P = .867), anteversion (P = .673), or both inclination and anteversion (P = .624).

Conclusion

Fluoroscopy is a useful tool for achieving a targeted acetabular component orientation in direct anterior THA, irrespective of patient BMI.  相似文献   

18.

Background

The aim of our study was to evaluate the clinical and radiographic outcomes of malseating of the acetabular liner in ceramic-on-ceramic total hip arthroplasty (THA).

Methods

Outcomes for 160 ceramic-on-ceramic THAs, contributed by 116 women and 39 men, were evaluated. Clinical and radiographic measurements were obtained over a 5- to 15-year follow-up for analysis.

Results

Liner malseating was identified in 20% of cases. Outcomes for 32 cases with liner malseating (group A) were compared to outcomes for 128 joints with correct liner seating (group B). The Harris hip score at the last follow-up was 90.1 for group A and 89.6 for group B. Osteolysis was identified in 5 cases in group A (15.6%), compared to 3 cases in group B (P < .001). No significant between-group differences were identified with regard to ceramic fracture, audible squeaking, loosening of components, and revision THA. The mean annual liner wear rate was comparable between groups, 0.0045 mm/y for group A and 0.0039 mm/y for group B. The 10-year Kaplan-Meier survivorship, based on an end point of revision THA, was 100% for group A and 99.0% for group B.

Conclusion

Over a moderate-length follow-up of 5-15 years, malseating of the acetabular liner was not associated with negative clinical outcomes or THA survivorship. Malseating did increase the incidence of osteolysis, a risk factor for adverse effects. Long-term follow-up studies are needed to fully quantify the effects of malseating of the acetabular liner.  相似文献   

19.

Background

Although most hip dislocations occur in either standing or sitting position, the safe zone for implant position is defined for the supine position. Our goal was to determine preoperative and postoperative pelvis and hip orientations and whether the safe zone defined in supine position can be used to assess standing radiographs.

Methods

Preoperative and postoperative three-dimensional EOS images were assessed in 66 total hip arthroplasty patients. None of the patients had dislocation within the follow-up period (12-36 months). The acetabular anteversion (both anterior pelvic plane [APP] and patient functional plane) and the femoral anteversion were measured. The sacral slope, pelvic version, pelvic inclination, and pelvic incidence were also measured.

Results

Acetabular anteversion increased postoperatively in both APP and patient functional plane (P <.001). Femoral neck anteversion decreased postoperatively (P =.0942). Sacral slope was 42.4° (?25.9° to 24°) preoperatively compared with 40.3° (?4.1° to 64.2°) postoperatively (P =.013). Pelvic version changed from 15.2° (?10.4° to 43.8°) to 17.2° (?6° to 46.7°; P = 0.008). Pelvic inclination was 1.12° (?25.9° to 24°) before total hip arthroplasty and ?1.2° (?40.7° to 23.4°) postoperatively (P =.005).

Conclusion

The acetabular and femoral implant orientations in standing position reside out of the safe zone in most patients. The APP is not vertical in standing position in most patients due to anterior or posterior pelvic tilt. The proposed safe zone in supine position may not be a useful measure in the assessment of standing radiographs of patients with significant anterior or posterior pelvic tilt.

Level of Evidence

Level IV, therapeutic case series study.  相似文献   

20.

Background

The use of porous tantalum for the acetabular component in primary total hip arthroplasty (THA) has demonstrated excellent short-term and midterm results. However, long-term data are scarce. The purpose of this prospective study is to report the long-term clinical and radiologic outcome following use of an uncemented porous tantalum acetabular component in primary THA with a minimum follow-up of 17.5 years, in a previously studied cohort of patients.

Methods

We prospectively followed 128 consecutive primary THAs in 140 patients, between November 1997 and June 1999. A press-fit porous tantalum monoblock acetabular component was used in all cases. All patients were followed clinically and radiographically for a mean of 18.1 years (range, 17.5-19 years).

Results

Mean age of patients at the time of operation was 60.4 years. Harris hip score, Oxford hip score, and range of motion were dramatically improved in all cases (P < .001). At last follow-up, all cups were radiographically stable with no evidence of migration, gross polyethylene wear, progressive radiolucencies, osteolytic lesions, or acetabular fractures. The survivorship with reoperation for any reason as end point was 92.8% and the survivorship for aseptic loosening as an end point was 100%.

Conclusion

The porous tantalum monoblock cup in primary THA demonstrated excellent clinical and radiographic outcomes with no failures because of aseptic loosening at a mean follow-up of 18.1 years.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号