首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《The Journal of arthroplasty》2021,36(10):3527-3533
BackgroundImageless computer navigation improves component placement accuracy in total hip arthroplasty (THA), but variations in the registration process are known to impact final accuracy measurements. We sought to evaluate the registration accuracy of an imageless navigation device during THA performed in the lateral decubitus position.MethodsA prospective, observational study of 94 patients undergoing a primary THA with imageless navigation assistance was conducted. Patient position was registered using 4 planes of reference: the patient’s coronal plane (standard method), the long axis of the surgical table (longitudinal plane), the lumbosacral spine (lumbosacral plane), and the plane intersecting the greater trochanter and glenoid fossa (hip-shoulder plane). Navigation measurements of cup position for each plane were compared to measurements from postoperative radiographs.ResultsMean inclination from radiographs (41.5° ± 5.6°) did not differ significantly from inclination using the coronal plane (40.9° ± 3.9°, P = .39), the hip-shoulder plane (42.4° ± 4.7°, P = .26), or the longitudinal plane (41.2° ± 4.3°, P = .66). Inclination measured using the lumbosacral plane (45.8° ± 4.3°) differed significantly from radiographic measurements (P < .0001). Anteversion measured from radiographs (mean: 26.1° ± 5.4°) did not differ significantly from the hip-shoulder plane (26.6° ± 5.2°, P = .50). All other planes differed significantly from radiographs: coronal (22.6° ± 6.8°, P = .001), lumbosacral (32.5° ± 6.4°, P < .0001), and longitudinal (23.7° ± 5.2°, P < .0001).ConclusionPatient registration using any plane approximating the long axis of the body provided a frame of reference that accurately measured intraoperative cup position. Registration using a plane approximating the hip-shoulder axis, however, provided the most accurate and consistent measurement of acetabular component position.  相似文献   

2.

Background

The acetabular component orientation in total hip arthroplasty (THA) is of critical importance to the good clinical results. However, traditional widely used cup alignment guides for cup placement are reported to be relatively unreliable. The present study aims at comparing a novel cup alignment guide, which can be attached to our anatomical pelvic plane (APP) pelvic lateral positioner for reducing discrepancies in sagittal pelvic tilt and indicate a targeted cup angle based on the APP, with a conventional cup alignment guide.

Methods

The subjects were 136 hips of 136 patients who underwent unilateral THA using the APP positioner. The procedure was performed with the conventional cup alignment guide (conventional group; 60 hips) and with the novel cup navigator (mechanical navigator group; 76 hips). Postoperative cup angles and discrepancies of postoperative cup angles (inclination and anteversion angles) from the targeted angles were compared between the 2 groups to evaluate the usefulness of these navigators.

Results

The mean cup angles in the conventional group were 39.0° ± 5.3° for the inclination angle and 21.7° ± 6.4° for the anteversion angle, whereas those in the mechanical navigator group were 40.6° ± 3.2° and 18.3° ± 4.6°, respectively (P = .018, P < .0001). The discrepancies from the targeted angles were 3.5° ± 3.1° for the inclination angle and 4.6° ± 3.4° for the anteversion angle in the conventional group and 2.3° ± 2.3° and 3.2° ± 2.7°, respectively, in the mechanical navigator group (P = .020, P = .012).

Conclusion

The mechanical cup navigator easily attachable to the APP positioner is a tool that can improve the accuracy of cup placement in a simple, economical, and noninvasive manner in THA via the lateral position.  相似文献   

3.
BackgroundMalposition of the acetabular component during total hip arthroplasty (THA) is associated with increased risk of dislocation, reduced range of motion, and accelerated wear. The purpose of this study is to compare cup positioning with a portable, accelerometer-based hip navigation system and conventional surgical technique.MethodsIn a prospective, randomized, clinical study, cups were implanted with a portable, accelerometer-based hip navigation system (navigation group; n = 55) or conventional technique (conventional group; n = 55). THA was conducted in the lateral position and through posterior approach. The cup position was determined postoperatively on pelvic radiograph and computed tomography scans.ResultsAn average cup abduction of 39.2° ± 4.6° (range, 27° to 50°) and an average cup anteversion of 14.6° ± 6.1° (range, 1° to 27.5°) were found in the navigation group, and an average cup abduction of 42.9° ± 8.0° (range, 23° to 73°) and an average cup anteversion of 11.6° ± 7.7° (range, −12.1° to 25°) in the conventional group. A smaller variation in the navigation group was indicated for cup abduction (P = .001). The deviations from the target cup position were significantly lower in the navigation group (P = .001, .016). While only 37 of 55 cups in the conventional group were inside the Lewinnek safe zone, 51 of 55 cups in the navigation group were placed inside this safe zone (P = .006). The navigation procedure took a mean of 10 minutes longer than the conventional technique.ConclusionUse of the portable, accelerometer-based hip navigation system can improve cup positioning in THA.  相似文献   

4.

Background

This study's purpose was to determine the impact of THA implantation on pelvic motion, and to assess motion in patients with a history of lumbar fusion or prosthetic dislocation.

Methods

This was an IRB-approved, prospective investigation of 3 cohorts: (1) patients without a history of lumbar surgery undergoing THA (group A), (2) patients with a lumbar fusion (group B), and (3) patients with a THA prosthetic dislocation (group C). All patients received both standing and sitting lateral pelvis images to measure sacral slope and pelvic tilt in the sagittal plane.

Results

Fifty-eight patients were enrolled (24 group A, 27 group B, and 7 group C), with no differences in age, gender, or body mass index (P = .1-.7). In group A, the mean change in sacral slope from standing to sitting was 22.1° ± 15.2° preoperatively and 19.5° ± 14.8° postoperatively. However, in 13 patients, the difference in pelvic motion from the standing to seated position, from preoperatively to postoperatively, was >5° and in 10 patients, this difference was >10°.The change in standing to sitting sacral slope was significantly less in patients with a lumbar fusion (9.8° ± 8.2°) and history of prosthetic dislocation (12.5° ± 4.7°) vs group A (P < .001 and P = .008).

Conclusion

Implantation of a THA can increase or decrease sagittal plane pelvic motion from the standing to seated position with a high degree of variability. Thus, the ability to predict ideal component positioning from preoperative images may be challenging.  相似文献   

5.

Background

Movement of the pelvis during implantation of total hip arthroplasty (THA) has a major influence on the positioning of the acetabular cup. Strong traction caused by retractors leads to iatrogenic pelvic lift and can thus be partly responsible for cup malpositioning. The objective of this study was to investigate such factors that influence pelvic lift.

Methods

The dynamic movement of the pelvis was measured during implantation of THA in 67 patients. This was done by measuring the acceleration using the SensorLog app on a smartphone.

Results

At its maximum, the pelvis was lifted by an average of 6.7°. When impacting the press-fit cup, the surgical side was raised by 4.4° compared with the time of skin incision. This lift at the time of cup implantation correlates significantly with the body mass index and the patient's abdominal and pelvic circumference.

Conclusion

Every surgeon performing THA must be aware of the pelvic lift during an operation. Especially in patients with a high body mass index, a large abdominal circumference, or a large pelvic circumference, there is an increased risk of malpositioning of the acetabular cup. When impacting the cup, we recommend releasing the traction of the retractor, so that the pelvis can tilt back into its natural position, and thus, the anticipated cup positioning can be implemented as exactly as possible.  相似文献   

6.

Background

The purpose of the study was to evaluate the implant positions and clinical results of revision total hip arthroplasty (THA) using an imageless navigation with the concept of combined anteversion.

Methods

A total of 40 cementless revision THAs (24 men and 16 women) using an imageless navigation with the concept of combined anteversion were retrospectively evaluated. The concept of combined anteversion was applied in cup positioning based on Widmer's equation (cup anteversion + 0.7 × stem anteversion). The mean follow-up period was 80.7 months. Postoperatively, the inclination of the cup was evaluated on standard anteroposterior view of the radiograph, and the anteversion of the cup and femoral stem was evaluated using computed tomography scan. A cup inclination of 40° ± 10° and combined anteversion of the cup and femoral stem of 37° ± 10° based on Widmer's equation were regarded as the “safe zone.”

Results

The average anteversion of the revised femoral stems was 15.3° ± 2.9° (range, 9.5°-21.5°), whereas that of the remained femoral stems was 17.4° ± 9.7° (range, 4.2°-29.8°). The inclination, anteversion of the cup, and combined anteversion after revision THA were 42.3° ± 3.1° (range, 32.1°-48.2°), 25.0° ± 2.9° (range, 16.9°-29.5°), and 36.1° ± 3.4° (range, 27.2°-42.9°), respectively. Therefore, the position of the implants, relative to the safe zone, showed no outliers after the revision surgery. Neither dislocation nor osteolysis was observed after the surgery.

Conclusion

Favorable results of this study indicate that imageless navigation helps the surgeon in placing the components of revision THA in the safe zone. This study also shows that when this safe zone is consistently obtained, then no postoperative dislocations were observed in these patients over the 6-year follow-up period.  相似文献   

7.

Background

Developmental hip dysplasia is the most common cause of secondary hip osteoarthritis. Due to severe acetabular bone deficiency, cup positioning in total hip arthroplasty (THA) of dysplastic hips remains a surgical challenge. The aim was to analyze the functional outcome of far proximal cup positions in primary THA.

Methods

Fifty patients (61 hips) with THA for severe dysplastic osteoarthritis and a far proximal cup position were included. Patients were divided according to the heights of the implanted cups with increasing vertical distance from the interteardrop line (group A: 55-65 mm, group B: 65-75 mm, group C: >75 mm). Functional outcome was assessed at latest follow-up (38 ± 16 months) by Lower Extremity Functional Score, Tegner Activity Score, and Harris Hip Score (HHS). Patients answered a Patient Satisfaction Questionnaire. Leg length discrepancy was estimated radiographically.

Results

The Lower Extremity Functional Score significantly decreased in C (45.3 ± 25) compared to A (66.7 ± 15.3) and B (67.9 ± 9.9). The Tegner Activity Score significantly increased in all subgroups from preoperative to postoperative (2.2 ± 1.3 to 4.1 ± 1.4; P < .05). The mean overall HHS was 89.3 ± 14.7 (A: 89.5 ± 14.3, B: 94.3 ± 6.5, C: 78.3 ± 22.1). The HHS domains of activity of daily life and gait were significantly reduced in C (P < .05). Patients described a high satisfaction level with the surgery. No significant differences were found with regard to preoperative and postoperative leg lengthening (P = .881). Neither dislocations, impingement problems nor neurologic complications were observed.

Conclusion

Primary THA without any concomitant surgical interventions with a far proximal cup position offers a safe and effective treatment option in severe dysplastic hip osteoarthritis.  相似文献   

8.
BackgroundAlthough pelvic osteotomy (PO) is an important surgical procedure that can alleviate symptoms and potentially slow progression of osteoarthritis in patients with development dysplasia of the hip, some patients eventually require conversion to total hip arthroplasty (THA). This study aimed to determine the outcome of conversion THA in patients with prior PO.MethodsForty nine patients with a history of prior PO who underwent conversion THA at a single institution were matched at a 1:3 ratio based on the date of surgery, age, gender, and body mass index with 147 developmental dysplasia of the hip patients who underwent primary THA without prior PO. A retrospective chart review was performed to compare outcomes at a minimum follow-up of 2 years.ResultsPatients with prior PO required more supplemental screw fixation for the acetabular component (59.2% vs 38.1%, P = .016), more autologous bone grafting (24.5% vs 11.6%, P = .048), had a longer mean operative time (106.0 vs 79.8 minutes, P < .001), and greater estimated blood loss (350.0 vs 206.8 mL, P = .015). Patients with prior PO had smaller cup version angle (26.0° vs 29.0°, P = .012) and greater discrepancy in the limb length (10.3 vs 7.26 mm, P = .041). Eight hips (16.3%) with prior PO and 6 (4.1%) without osteotomy required reoperation (P = .008). There was no difference in outcome scores at the latest follow-up.Conclusion: THA after prior PO is technically demanding, leading to longer operative times, greater blood loss, and variation in implant placement. Although functional outcomes are similar, THA after a prior PO is more likely to require reoperation.ConclusionTHA after prior PO is technically demanding, leading to longer operative times, greater blood loss, and variation in implant placement. Although functional outcomes are similar, THA after a prior PO is more likely to require reoperation.  相似文献   

9.
The usefulness of navigation systems for revision total hip arthroplasty (THA) remains unclear. The purpose of this study was to evaluate the accuracy of cup positioning using a navigation system in revision THA. Cup alignment of thirty revision cases was evaluated. Data were also compared with those of 30 navigated primary THA cases. In the revision THA group, mean difference in postoperative measurement from preoperative plan was 0.5 ± 4° (range, − 9° to 8°) for inclination and − 0.07° ± 5° (− 14° to 13°) for anteversion. Mean difference in postoperative measurement from intraoperative record was 0.7° ± 3° (− 5° to 8°) for inclination and − 0.7° ± 3° (− 12° to 5°) for anteversion. Compared with the primary THA group, none of these parameters were significantly different. This navigation system was useful even in revision THA.  相似文献   

10.

Background

We sought to evaluate the outcomes of cementless acetabular components used in patients with Crowe II and III dysplasia, and to compare outcomes between cups placed within vs outside of an “anatomic” zone. Our specific aims were to (1) plot hip centers in these patients at our institution to characterize “anatomic” vs “nonanatomic” positions, (2) evaluate the association between hip center and radiographic loosening, (3) determine whether hip center was associated with acetabular component revision, and (4) compare patient-reported outcome scores between groups.

Methods

We retrospectively reviewed 88 primary cementless total hip arthroplasties at a mean follow-up of 10 years (range 2-26 years). Patients were 85% female, with a mean age of 44 years (range 28-61 years) and a body mass index of 27 kg/m2 (range 19-42 kg/m2). Medical records and radiographs were reviewed, and a survey was conducted for all patients. Anatomic hip center was defined using the 4-zone system, wherein centers are “anatomic” if they are <1 cm superior and <1 cm lateral to the approximate femoral head center. Cox proportional analyses were used to compare outcomes between groups.

Results

Seventy hips (80%) had an anatomic hip center. Anatomic hips had a lower incidence of radiographic acetabular loosening (0% vs 17%, P = .007) and cup revision (0% vs 28%, P = .0002). There were no differences in Hip Disability and Osteoarthritis Outcome and Joint Replacement Scores (96.2 ± 5 vs 91.9 ± 12, P = .7).

Conclusion

The incidence of aseptic loosening and cup revision were lower when hip center was <1 cm superior and 1 cm lateral to the approximate femoral head center.  相似文献   

11.
We prospectively evaluated acetabular cup placement in total hip arthroplasty with an imageless computer navigation system or using conventional manual technique. The achieved cup orientation in the manual group had substantially larger variances and greater placement error than the navigation cases. The use of navigation was abandoned in 3 cases because of excessive pelvic tilt and unreliable registration of the pelvis. Computer navigation system helped improve the accuracy of the acetabular cup placement for total hip arthroplasty in this study. The variation between the intraoperative navigation readings and the computed tomographic values suggests that relying on palpation of bony landmarks through drapes and tissue is a limitation of this method. Further, the variation in pelvic tilt has an effect on cup placement that requires further studies.  相似文献   

12.
Despite advances in surgical techniques and instrumentation, optimal cup positioning in total hip arthroplasty (THA) is challenging with a limited accuracy. We evaluated whether a learning curve exists for the optimal cup positioning, using the LC-CUSUM test (Learning curve cumulative summation test). We evaluated the first 100 consecutive THA performed by two surgeons, who had a year of fellowship training in the same teaching hospital. A learning curve of cup positioning was plotted in each series using the LC-CUSUM score. There was no significant difference of numbers of outlier between two surgeons (P = 0.079). Both surgeons completed the learning curve of optimal cup positioning before 50 procedures, and maintained competence. A substantial learning period is necessary in the optimal positioning of an acetabular cup.  相似文献   

13.
14.

Background

Cup anteversion and inclination are important for avoiding implant impingement and dislocation in total hip arthroplasty. However, functional cup anteversion and cup inclination also change as the pelvic sagittal inclination (PSI) changes. Therefore, PSI in both supine and standing positions was measured in a large cohort in this study.

Methods

A total of 422 patients (median age, 61; range, 15-87) who underwent total hip arthroplasty were the subjects of this study. There were 83 patients with primary osteoarthritis (OA), 274 patients with developmental dysplasia–derived secondary OA, 48 patients with osteonecrosis, and 17 patients with rapidly destructive coxopathy (RDC). Preoperative PSI in supine and standing positions was measured by automated computed topography segmentation and landmark localization of the pelvis followed by intensity-based 2D-3D registration, and the number of cases in which PSI changed more than 10° posteriorly was calculated. Hip disease, sex, and age were analyzed if they were related to a PSI change of more than 10°.

Results

The median PSI was 5.1° (interquartile range, 0.4°-9.4°) in supine and ?1.3° (interquartile range, ?6.5° to 4.2°) in standing position. There were 79 cases (19%) in which the PSI changed more than 10° posteriorly from supine to standing. Elder age and patients with primary OA and RDC were revealed to be the related factors.

Conclusion

PSI changed more than 10° posteriorly from supine to standing in 19% of cases. Age and diagnosis of primary OA and RDC were the significant factors for the posterior rotation.  相似文献   

15.
《The Journal of arthroplasty》2020,35(12):3621-3626
BackgroundThis study is prospectively conducted to evaluate surgical complications of monolithic dual mobility cup total hip arthroplasty (THA) in elderly patients with fractured neck of the femur.MethodsNinety-seven patients (97 hips) with displaced femoral neck fracture who gave informed consent for participation were prospectively enrolled. Their mean age was 76.6 years (range, 60-95 years), and the mean bone mineral density T-score of neck of the femur was −2.8 (range, −1.2 to −5.5). All patients underwent THA with monolithic dual mobility cup, and computed tomography scans were obtained to evaluate radiographic parameters including anteversion, inclination, and loosening of acetabular cups, and periprosthetic acetabular fractures.ResultsWith regard to cup orientation, mean inclination angle was 40.2° (range, 23.5°-63°) and mean anteversion was 32.6° (range, 7°-66.2°). The proportion of surgical outliers was 10.3% (10/97) in inclination and 35.1% (34/97) in anteversion. Early cup loosening within 2 weeks was detected in 2 hips. Periprosthetic acetabular fractures were identified in 6 hips (6/97, 6.2%). Of the 6 fractures, 5 nondisplaced fractures were healed with conservative management, but 1 fracture with displacement eventually led to cup loosening and the patient underwent revision surgery. Reoperation rate of the monolithic dual mobility cup was 4.1% (4/97).ConclusionThe use of the monolithic dual mobility was associated with improper cup fixation and periprosthetic acetabular fractures in the elderly with poor bone stock, although the dual mobility cup lowered the risk of early dislocation after THA.  相似文献   

16.
BackgroundAnterior and posterior pelvic tilt appears to play a role in total hip arthroplasty (THA) stability. When changing from the standing to the sitting position, the pelvis typically rotates posteriorly while the hips flex and this affects the femoro-acetabular positions. This case-control study compares changes in 3-D acetabular cup orientation during functional pelvic tilt between posterior THA dislocations vs stable THAs.MethodsStanding and sitting 3-D cup orientation was compared between fifteen posterior dislocations vs 233 prospectively followed stable THAs. 3-D cup orientation was calculated using previously validated trigonometric algorithms on biplanar radiographs. Those algorithms combine the angles in the three anatomical planes (coronal inclination, transverse version, and sagittal ante-inclination) in the standing position with the change in sagittal pelvic tilt from standing to sitting to calculate the 3-D orientation in the sitting position.ResultsThe standing cup orientation of the dislocated THAs was only characterized by a lower coronal inclination (P = .039). Compared with the controls, from standing to sitting, they showed less posterior pelvic tilt (P < .001). This led to a significant lower coronal inclination (P < .001) and sagittal ante-inclination (P < .001) in the sitting position but similar transverse version (P = .366).ConclusionsComparing posterior THA dislocations to stable THAs, there is a lower increase of all three orientation angles from standing to sitting. This leads to a decreased sitting coronal inclination and sagittal ante-inclination which may lead to an increased risk of impingement ensued by THA instability. By contrast, the transverse version was not significantly different in both positions. This confirms the importance of biplanar data on functional cup orientation.Level of EvidenceDiagnostic, Level III.  相似文献   

17.

Background

Noise after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) is a well-recognized problem. Computer navigation has been shown to achieve desired implant orientation. Our aim was (1) to compare the incidence of noise between navigated and conventional CoC THAs and (2) to determine the factors associated with noise.

Methods

All patients undergoing CoC THA between March 2009 and August 2012 were considered for this study. Information regarding hip noise was obtained via telephone or postal interview. A comparable cohort of patients in navigated and conventional groups was used to evaluate the incidence of noise.

Results

A total of 375 CoC THAs using the same implant (202 navigated and 173 conventional) were evaluated. Patients <65 years of age had significantly greater incidence of noise (22.4% vs 6.1%; P < .001). To ensure similarity, a subgroup of cohort <65 years and a 32-mm head size was used to compare the incidence of noise between the navigated (68 THAs) and conventional (118 THAs) groups. Overall incidence of noise was significantly greater in the conventional group (28%) as compared with the navigated group (10%; P = .005). The relative risk of noise for the conventional vs the navigated group was 2.7 (P = .01), and for squeaking was 1.9 (P = .2). Squeaking THAs had significantly lower cup anteversion (13.4° ± 5.2°) as compared with the silent THAs (17.6° ± 6.9°; P = .01).

Conclusion

Navigated CoC THAs were 2.7× less likely to have noise as compared with the conventional ones. Squeaking THAs had significantly lower cup anteversion as compared with the silent ones. Patients of age <65 years had significantly greater incidence of noise after CoC THA.  相似文献   

18.
Proper femoral and acetabular component position and leg length equality are important intraoperative considerations during total hip arthroplasty. Unfortunately, traditional surgical techniques often lead to suboptimal component position, and such deviations have been associated with increased rates of prosthetic wear, dislocation, component loosening, and patient dissatisfaction. Although surgical navigation has been shown to improve reproducibility of component alignment, such technology is not universally available and is associated with significant costs and additional surgical/anesthetic time. In the current study, we found that a routine intraoperative pelvic radiograph could successfully identify malpositioned components and leg length inequalities and could allow for successful correction of identified problems. Unexpected component malposition and leg length inequality occurred in only 1.5% of cases where an intraoperative pelvic radiograph was utilized.  相似文献   

19.
Relative risk of impingement and joint instability during sexual activities after total hip arthroplasty (THA) has never been objectively investigated. Hip range of motion necessary to perform sexual positions is unknown. A motion capture study with two volunteers was performed. 12 common sexual positions were captured and relevant hip joint kinematics calculated. The recorded data were applied to prosthetic hip 3D models to evaluate impingement and joint instability during motion. To explore the effect of acetabular component positioning, nine acetabular cup positions were tested. Four sexual positions for women requiring intensive flexion (> 95°) caused prosthetic impingements (associated with posterior instability) at 6 cup positions. Bony impingements (associated with anterior instability) occurred during one sexual position for men requiring high degree of external rotation (> 40°) combined with extension and adduction at all cup positions. This study hence indicates that some sexual positions could be potentially at risk after THA, particularly for women.  相似文献   

20.
Newer arthroplasty designs claim to provide superior range of motion (ROM) and greater stability than their predecessors. However, there is no way to compare ROM of implant systems in an equivalent anatomical environment in a clinical setting. This study used computer-aided design to compare ROM after hip resurfacing, 28 mm THA, 36 mm THA, and anatomic dual mobility (ADM) THA in 3D models of 5 cadaver pelvises. ROM to impingement was then tested in 10 different motions and a one-way ANOVA was used to compare results. The hip resurfacing resulted in restricted ROM compared to the other 3 models in all motions except adduction. The ADM, 36 mm, and 28 mm THA resulted in similar ROM. Dual mobility constructs provide comparable ROM in patients where large head THA is not appropriate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号