首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.

Background

The global rise in infectious disease has led the Center for Disease Control and Prevention and the World Health Organization to release new guidelines for the prevention of surgical site infection.

Methods

In this article, we summarize current recommendations based on level of evidence, review unresolved and unaddressed issues, and supplement them with new literature.

Results

Although the guidelines discuss major issues in reducing surgical site infection, many questions remain unanswered.

Conclusion

These guidelines will hopefully help in setting a standard of care based on best evidence available and focus investigators on areas where evidence is lacking.  相似文献   

3.

Background

The purpose of this study was to compare the clinical outcomes after 2-stage revision with those following single-stage revision in patients who developed periprosthetic joint infection after primary hip arthroplasty.

Methods

Between January 2004 and January 2013, we retrospectively reviewed patients who developed periprosthetic joint infection after primary hip arthroplasty and who underwent surgery for placement of a prosthesis made of antibiotic-loaded acrylic cement (PROSTALAC). Patients were divided into 2 groups based on the stages of revision. Group A was made up of patients who had undergone 2-stage revision using PROSTALAC as an interim prosthesis. Group B was made up of patients who had been compelled to undergo single-stage revision using PROSTALAC as an alternative implant because of older age and/or medical problems. Clinical outcomes were evaluated using a visual analog scale to score pain by calculating the Harris Hip Score and by determining the patient's walking ability.

Results

There were 20 patients in group A and 19 patients in group B. The mean follow-up period after final surgery was 68.8 months (range, 24-114 months). The infection resolution rate after initial PROSTALAC placement was 92.3%, and the final resolution rate was 94.9%. The visual analog scale and Harris Hip Score of group A were significantly better than those of group B. However, no significant difference in walking ability was found between the 2 groups.

Conclusion

Although the clinical outcomes in patients with PROSTALAC implants were not as good as those who underwent 2-stage revision, PROSTALAC can be a useful alternative implant in selected patients who are debilitated because of older age and/or who have critical medical problems.  相似文献   

4.

Background

The purpose of this study was to compare the long-term clinical results, radiographic results, range of knee motion, patient satisfaction, and the survival rate of Medial-Pivot posterior cruciate-substituting, knee prosthesis and a press-fit condylar (PFC) Sigma cruciate-retaining mobile-bearing knee prosthesis in the same patients.

Methods

One hundred eighty-two patients received Medial-Pivot knee prosthesis in one knee and a PFC Sigma knee prosthesis in the contralateral knee. The minimum duration of follow-up was 11 years (range, 11-12.6 years).

Results

The knees with a Medial-Pivot knee prosthesis had significantly worse results than those with a PFC Sigma knee prosthesis at the final follow-up with regard to the mean postoperative Knee Society knee scores (90 compared with 95 points), Western Ontario and McMaster Universities Osteoarthritis Index score (25 compared with 18 points), and range of knee motion (117° compared with 128°). Patients were more satisfied with PFC Sigma knee prosthesis (93%) than with Medial-Pivot knee prosthesis (75%). Complication rates were significantly higher in the Medial-Pivot knee group (26%) than those in the PFC Sigma knee group (6.5%). Radiographic results and survival rates (99% compared with 99.5%) were similar between the 2 groups.

Conclusion

Although the long-term fixation and survival rate of both Medial-Pivot and PFC Sigma prostheses were similar, we observed a worse knee score, worse range of knee motion, and patient satisfaction was less in the Medial-Pivot knee group than in the PFC Sigma knee group. Furthermore, complication rate was also higher in the Medial-Pivot knee group than the other group.  相似文献   

5.

Background

Total knee arthroplasty in the presence of a huge bone and soft-tissue defect is always a challenge. A rotating-hinged (RH) megaprosthesis is indicated for extensive soft-tissue loss with a huge bone defect such as a primary or metastatic neoplasm of the bone, repeat periprosthetic joint infection, or extensive trauma of the knee. However, the reported survivorship of RH megaprostheses is unsatisfactory. The aim of this study was to evaluate the survivorship of megaprostheses and the factors that contribute to implant survival.

Methods

A total of 103 RH knee megaprostheses were implanted in 85 patients between January 2001 and June 2013. Each prosthesis was a modular custom-made (CM) cemented or cementless fixed total knee system (United USTAR system). Clinical results and prosthesis survivorship were evaluated between the 2 groups.

Results

The overall survivorship of this CM knee megaprosthesis was 91% at 2 years, 83% at 5 years, and 68% at 10 years. The cumulative component survivorship was 87% in the cemented group and 96% in the cementless group at 2 years compared with 75% in the cemented group and 94% in the cementless group at 5 years. The failure mechanism included loosening in 5 and breakage in 6 patients in the cemented stem group. The survivorship of the cementless fixed component was significantly superior to that of the cemented fixed component.

Conclusion

Our data suggest that modular RHCM knee megaprosthesis provides an acceptable clinical result. A diaphyseal long stem with cementless fixation was more reliable and durable than its cemented counterpart.  相似文献   

6.

Background

Use of leukocyte esterase (LE) testing of synovial fluid as an adjunct to the infection workup in total joint arthroplasty patients has been advocated. The purpose of this study was to determine the false positive rate of this test.

Methods

Two hundred patients with the diagnosis of degenerative osteoarthritis undergoing a total knee arthroplasty were identified for this study. The knee joint was aspirated under sterile conditions before performing the total knee arthroplasty. The fluid was analyzed with an LE reagent strip.

Results

There were 27 bloody and 17 dry aspirations. One hundred forty-nine patients produced an aspiration that allowed for LE testing. There was 1 positive LE result. The specificity of the LE test was found to be 99.3%.

Conclusion

These data suggest the LE strip as a part of the workup for infection in a native knee should yield few false positive results.  相似文献   

7.

Background

De novo gastric cancer is a rare complication of liver transplantation.

Methods

Surgical treatments of 16 cases with different outcomes were reported in the English literature.

Results

De novo gastric cancer (stage II) was diagnosed as the result of epi-gastric discomfort in a recipient 10 years after liver transplantation. The patient received chemotherapy alone and remained well for 26 months.

Conclusions

De novo gastric cancer of liver transplantation recipients is a severe complication; early detection and relevant intervention will benefit these recipients.  相似文献   

8.

Background

The purpose of our prospective, randomized, long-term investigation is to compare the aseptic loosening rate of the femoral component of the total knee prosthesis and clinical and radiographic results of high-flexion posterior cruciate-substituting knee prosthesis or standard posterior cruciate-substituting knee prosthesis in the same patients.

Methods

There were 960 patients (mean age 71.3 years). The mean follow-up period was 13.2 years (range 10-14). The patients were assessed clinically and radiographically with rating systems of the Knee Society. Furthermore, Western Ontario and McMaster Universities Osteoarthritis questionnaire and ranges of knee motion were determined in both groups.

Results

In the high-flexion knee group, 2 knees (0.2%) had aseptic loosening of both femoral and tibial components. In the standard knee group, 2 knees (0.2%) had aseptic loosening of the femoral component only. The mean postoperative knee scores (97 vs 97 points), Western Ontario and McMaster Universities Osteoarthritis scores (19 vs 19 points), and range of knee motion (128° vs 129°) were not significantly different between the 2 groups. Two knees (0.2%) in the high-flexion knee group underwent a revision of both femoral and tibial components and 2 knees (0.2%) in the standard knee group had a revision of the femoral component only.

Conclusion

After a mean of 13.2 years of follow-up, this study did not show increased incidence of femoral component loosening in the high-flexion knee group. Furthermore, we found no significant differences between the 2 groups with regard to clinical or radiographic parameters or range of knee motion.  相似文献   

9.

Background

In total hip arthroplasty, short stems were developed as a bone-conserving alternative to traditional cementless stems. So far, there have been very few recorded medium to long-term results of these comparatively new implants. The aim of our retrospective study was to report on the survival of calcar-loading short stems.

Methods

All Metha stem implantations from 2004 to 2014 were recorded from the operation protocols (n = 1888). Due to the chronological development of the stem, 3 different versions were implanted: modular titanium stems with neck adapters from titanium or cobalt-chrome and monoblock stems. Patients were questioned by post about revision, dislocation, and satisfaction.

Results

Data were complete for 93% of the procedures (1090 monoblock stems, 314 modular stems with titanium neck, and 230 modular stems with cobalt chrome neck). Mean follow-up was 6 years (1-11 years). Fifteen modular titanium implants were affected by cone fractures (4%). Therefore, monoblock, modular cobalt chrome, and modular titanium implants were analyzed separately. The 7-year revision rate for monoblock stems was 1.5%; for modular cobalt-chrome stems it was 1.8%, and for modular titanium stems it was 5.3%.

Conclusion

Our data show the midterm survival of the monoblock and modular cobalt-chrome implants equivalent to the traditional cementless stems. These might, therefore, be considered as a bone-conserving alternative for young and active patients.  相似文献   

10.

Background

Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty.

Methods

Based on 95 retrieved polyethylene inserts, wear and damage patterns were analyzed in relationship to the overall mechanical alignment and to the position of the tibial component.

Results

A progression of wear was observed with progressively mechanical varus alignment. However, there was significantly more damage in the lateral compartment in the mild and moderate varus group compared to the valgus group. No difference in damage was seen between all groups for tibial component positioning in valgus or varus.

Conclusion

Progressive wear was observed with progressively varus alignment with more damage at the lateral side. This observation is unique and might be explained by lateral condylar lift-off inducing impact and shear loading in the varus group.  相似文献   

11.

Background

The R3 acetabular system used with its metal liner has higher revision rates when compared to its ceramic and polyethylene liner. In June 2012, the medical and healthcare products regulatory agency issued an alert regarding the metal liner of the R3 acetabular system.

Methods

Six retrieved R3 acetabular systems with metal liners underwent detailed visual analysis using macroscopic and microscopic techniques.

Results

Visual analysis discovered corrosion on the backside of the metal liners. There was a distinct border to the areas of corrosion that conformed to antirotation tab insertions on the inner surface of the acetabular shell, which are for the polyethylene liner. Scanning electron microscopy indicated evidence of crevice corrosion, and energy-dispersive X-ray analysis confirmed corrosion debris rich in titanium.

Conclusion

The high failure rate of the metal liner option of the R3 acetabular system may be attributed to corrosion on the backside of the liner which appear to result from geometry and design characteristics of the acetabular shell.  相似文献   

12.

Background

The aim of the study was to compare the clinical and radiographic results of consecutive ceramic-on-ceramic bearings with and without a metal-backed titanium sleeve in patients undergoing total hip arthroplasty.

Methods

Eighty-five patients (64 women and 21 men; average age 55.2 years) were included in the A group without sleeve while 147 patients (116 women and 31 men; average age 54.2 years) were included in the B group with sleeve. Clinical and radiologic measurements at follow-up (range, 5-14 years; average, 8.1 years) were analyzed.

Results

The mean latest postoperative Harris Hip Score was 89.1 for patients from both groups. One joint (1.2%) in the A group displayed ceramic liner fracture, while no incidences of liner fracture occurred in the B group. Audible squeaking was observed in 1 joint (1.2%) in the A group and 1 (0.7%) in the B group. The mean annual liner rate of wear was 0.0049 and 0.0046 mm/y for the A group and B group, respectively. Three joints in the A group (3.5%) required revision total hip arthroplasty because of individual episodes of aseptic cup loosening, ceramic liner fracture, and infection. One joint in the B group (0.7%) required revision because of progressive osteolysis of the proximal femur. Ten-year Kaplan–Meier survivorship, based on an end point of component loosening and bearing failure, was 97.6% for the A group and 99.3% for the B group.

Conclusion

There were no clinical, radiographic, or survivorship differences between groups.  相似文献   

13.

Background

Periprosthetic joint infection (PJI) remains one of the most challenging and devastating modes of failure after total hip and knee arthroplasties. Despite the profound urgency and impact of PJI on an individual and societal basis, historically, there have not been standardized definitions of and diagnostic algorithms for infection after total joint arthroplasty.

Methods

In a recent symposium, the American Academy of Hip and Knee Surgeons put forth a standardized approach to the prevention, diagnosis, and management of the patient with a suspected PJI.

Results

This review article summarizes these findings, and reviews the algorithmic approach to the diagnosis of PJI.

Conclusion

The diagnosis of PJI is easily made in our experience in 90% of patients by getting an erythrocyte sedimentation rate and C-reactive protein followed by selective aspiration of the joint if these values are elevated or if the clinical suspicion is high. Synovial fluid obtained should be sent for a synovial fluid white blood cell count, differential, and cultures.  相似文献   

14.

Background

Periprosthetic joint infection is the most common cause of readmissions after total joint arthroplasty (TJA). Intrawound vancomycin powder (VP) has reduced infection rates in spine surgery; however, there are no data regarding VP in primary TJA.

Methods

Thirty-four TJA patients received 2 g of VP intraoperatively to investigate VP's pharmacokinetics. Serum and wound concentrations were measured at multiple intervals over 24 hours after closure.

Results

All serum concentrations were subtherapeutic (<15μg/mL) and peaked 12 hours after closure (4.7μg/mL; standard deviation [SD], 3.2). Wound concentrations were 922 μg/mL (SD, 523) 3 hours after closure and 207 μg/mL (SD, 317) at 24 hours. VP had a half-life of 7.2 hours (95% confidence interval, 7.0-9.3) in TJA wounds.

Conclusions

VP produced highly therapeutic intrawound concentrations while yielding low systemic levels in TJA. VP may serve as a safe adjunct in the prevention of periprosthetic joint infection.  相似文献   

15.

Background

Minimally invasive surgery (MIS) has perceived advantages in the early postoperative stage for total knee arthroplasty (TKA). It is not clear whether the improved radiographic alignment achieved by computer-assisted navigation surgery (CAS) improves midterm clinical outcomes. The aim of this study was to compare patient outcomes of MIS TKA performed with and without CAS after a minimum follow-up of 7 years.

Methods

Between 2007 and 2009, 50 patients underwent CAS and MIS TKA, and 50 patients underwent jig-based MIS TKA in this prospective study. Ninety-six patients were evaluated after a mean follow-up of 7.7 years, and clinical and radiological evaluations were performed.

Results

Midterm results demonstrated that the Knee Society knee score, function score, and range of motion were comparable in the 2 groups. The percentage of patients with the mechanical axis within ±3° of neutral was significantly higher in the CAS group than in the jig-based group (94% vs 79%, respectively; P = .038). No knees had loosening after TKA. However, 1 patient in the CAS group demonstrated late infection 4 years postoperatively.

Conclusion

CAS did not improve midterm outcomes after MIS TKA compared with jig-based surgery, although CAS reduced outliers in coronal alignment.  相似文献   

16.

Background

Although venous thromboembolism is one of the leading causes of morbidity after knee arthroplasty, little data exist on the risk of deep venous thrombosis (DVT) after unicompartmental knee arthroplasty (UKA).

Methods

We prospectively enrolled 112 patients undergoing UKA to determine the incidence of DVT utilizing aspirin 325 mg twice a day (BID) for 4 weeks postoperatively as DVT prophylaxis. The data were compared with a recent randomized controlled trial of patients undergoing total knee arthroplasty utilizing aspirin and Lovenox in conjunction with pneumatic compression devices.

Results

One patient (0.9%) had an asymptomatic DVT, and none developed clinical symptoms of either DVT or pulmonary embolus. The incidence of asymptomatic and symptomatic DVT was 0.9% and 0%, respectively.

Conclusion

Our data suggest that 325 mg of aspirin BID for 4 weeks results in a very low risk of DVT for patients undergoing UKA.  相似文献   

17.

Background

Both modular and nonmodular tapered fluted titanium stems are used in revision total hip arthroplasty (THA), with follow-up showing good results for both stems. We aimed to determine whether there were any differences in clinical outcomes, survivorship, or frequency of complications.

Methods

A retrospective review of 160 consecutive THAs (153 patients) revised with a tapered fluted modular titanium stem from 2002 to 2014 and 129 consecutive THAs (128 patients) revised with a tapered fluted nonmodular titanium stem between 2008 and 2014 was conducted. The patient's level of satisfaction, clinical assessment, and complications were examined. A Kaplan-Meier survivorship analysis was performed with the endpoint defined as any reoperation due to septic/aseptic complications.

Results

Mean duration of follow-up was longer in the modular group (6.3 years) than the nonmodular group (5.0 years; P = .003). No significant group differences were found in the postoperative Harris Hip Score, the level of overall satisfaction, the 8-year cumulative survival, the rate of infection, dislocation, or postoperative periprosthetic fractures. However, intraoperative fractures occurred significantly more frequently in the modular group (16.9%) than in the nonmodular group (7.0%; P = .011), and stem subsidence was significantly less in the modular group (0.95 mm) than in the nonmodular group (1.93 mm; P = .001). Two mechanical failures associated with the modular design occurred in the modular group.

Conclusion

Both modular and nonmodular tapered fluted titanium stems provide satisfactory midterm results in revision THA. Although tapered fluted modular stems are gaining in popularity in revision THA, tapered fluted nonmodular stems should not be disregarded as a viable alternative, especially for relatively straightforward cases.  相似文献   

18.

Background

We are reporting on the minimum 5-year outcomes of patients who underwent revision total hip arthroplasty (THA) using a specific highly-porous titanium shell. We assessed (1) aseptic and all-cause survivorship; (2) functional outcomes; (3) complications; and (4) radiographic outcomes.

Methods

Two hospital databases were evaluated for patients who underwent revision THA due to component instability or aseptic loosening using a cementless highly-porous titanium shell between September 2006 and December 2011. This yielded 35 patients who had a mean age of 61 years (range 14-88 years). Patients had a mean follow-up of 6 years (minimum 5 years). All-cause and aseptic survivorship of the shell was calculated. Functional outcomes were assessed using the Harris Hip Score. We determined the incidence of postoperative complications and performed radiographic evaluation of pelvic radiographs from regular office visits.

Result

The aseptic survivorship of the acetabular component was 97% (95% confidence interval; 8.1-9.5). The all-cause survivorship of the acetabular component was 91% (95% confidence interval; 7.3-8.1). One patient had an aseptic failure and 2 patients had septic failures. The mean postoperative Harris Hip Score was 76 points (range, 61-91 points). Excluding the aseptic and septic failures, there was no osteolysis or progressive radiolucencies present on radiographic evaluation at final follow-up.

Conclusion

At a minimum of 5-year follow-up, the highly-porous titanium acetabular revision shell has excellent survivorship and functional outcomes. Although long-term follow-up is needed to further monitor these implants, the results are promising and demonstrate that this prosthesis may be an excellent option for patients undergoing revision THA.  相似文献   

19.

Background

Periprosthetic fracture following total hip arthroplasty is a significant problem faced by hip surgeons, and its management in elderly patients remains a considerable challenge.

Methods

We retrospectively reviewed 28 Vancouver B2 and B3 periprosthetic femoral fractures (PFF) treated with revision of the femoral stems by distally locked, hydroxyapatite-coated uncemented stems (Cannulok). Patients were aged 75 years or older at the time of surgery.

Results

The mean follow-up was 44.6 months (range, 24-102). The mean postoperative Oxford hip score was 30.1 (range, 10-46). The rate of fracture union was 95.8%, and the survivorship of the stem was 100% at the end of follow-up.

Conclusion

The management of PFF in elderly is associated with increased postoperative morbidity and mortality. The use of a distally locked, hydroxyapatite-coated femoral stem is a valid option for the treatment of PFF to achieve fracture union with a low rate of revision.  相似文献   

20.

Background

Blood loss occurs significantly more frequently during total hip and knee arthroplasty than among any other type of orthopedic operation, which can sometimes lead to requiring a blood transfusion. Although allogeneic blood transfusion has been identified as a risk factor for postoperative surgical-site infection following arthroplasty, results are inconclusive. The purpose of this study was to conduct a systematic meta-analysis to investigate whether having an allogeneic blood transfusion significantly increases the risk for surgical-site infection, particularly after total hip and knee arthroplasty.

Methods

We performed a systematic review and meta-analysis using random-effect models. Using an electronic database search, we selected 6 studies that included data on 21,770 patients and among these studies compared the postoperative infection rate between an allogeneic blood-transfusion exposure group and a nonexposure group. We calculated the pooled odds ratios and 95% confidence intervals for the groups.

Results

The prevalences of surgical-site infections in our pooled analyses were 2.88% and 1.74% for the transfusion and nontransfusion groups, respectively. The allogeneic blood transfusion group had a significantly higher frequency of surgical-site infections based on pooled analysis using a random-effect model (pooled odds ratio = 1.71, 95% confidence interval: 1.23-2.40, P = .002).

Conclusion

Allogeneic blood transfusion is a significant risk factor for increasing the surgical-site infection rate after total hip and knee arthroplasty.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏