首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
PurposeTo compare procedure duration and patient radiation dose in positron emission tomography/computed tomography (PET/CT) and CT-guided liver tumor ablation procedures.Materials and MethodsIn this retrospective, case-control study, 275 patients underwent 368 image-guided ablation procedures to treat 537 tumors. Radiologists used PET/CT guidance for 117 procedures and CT guidance for 251 procedures. PET/CT-guided procedures were performed by one radiologist (C: P.B.S.). All 3 radiologists (A: J.G.S., B: a radiologist who is not an author on this article, and C: P.B.S.) performed CT-guided procedures. Potential confounders included patient demographics, clinical and tumor characteristics, and procedural variables.ResultsThe mean duration and estimated patient radiation dose of PET/CT-guided procedures performed by radiologist C were 21.5 ± 4.9 minutes longer and 0.7 ± 2.8 mSv higher than CT-guided procedures performed by all radiologists in an unadjusted comparison. Adjusting for confounding, mean duration and estimated dose of PET/CT-guided procedures performed by radiologist C were 28.3 ± 3.8 minutes longer (P < .0001) and 6.2 ± 2.9 mSv higher (P = .03) than CT-guided procedures performed by the same radiologist. Comparing CT-guided procedures performed by all 3 radiologists, adjusted mean durations and estimated patient doses of procedures by the least experienced radiologist, radiologist A, and the second most experienced radiologist, radiologist B, were 24.2 ± 5.1 (P < .0001) and 18.1 ± 8.9 (P = .04) minutes longer and 13.1 ± 3.7 (P < .001) and 14.5 ± 6.4 (P = .02) mSv higher, respectively, than procedures performed by the most experienced radiologist, radiologist C.ConclusionsPET/CT-guided liver ablations had a slightly longer duration with slightly higher estimated patient radiation dose than similar CT-guided liver ablations. Procedure duration and patient dose do not appear to be major impediments to the emerging field of PET/CT-guided tumor ablation.  相似文献   

2.
PurposeTo evaluate the feasibility and accuracy of a robotic system to integrate and map computed tomography (CT) and robotic coordinates, followed by automatic trajectory execution by a robotic arm. The system was hypothesized to achieve a targeting error of <5 mm without significant influence from variations in angulation or depth.Materials and MethodsAn experimental study was conducted using a robotic system (Automated Needle Targeting device for CT [ANT-C]) for needle insertions into a phantom model on both moving patient table and moving gantry CT scanners. Eight spherical markers were registered as targets for 90 insertions at different trajectories. After a single ANT-C registration, the closed-loop software targeted multiple markers via the insertion of robotically aligned 18-gauge needles. Accuracy (distance from the needle tip to the target) was assessed by postinsertion CT scans. Similar procedures were repeated to guide 10 needle insertions into a porcine lung. A regression analysis was performed to test the effect of needle angulation and insertion depth on the accuracy of insertion.ResultsIn the phantom model, all needle insertions (median trajectory depth, 64.8 mm; range, 46.1–153 mm) were successfully performed in single attempts. The overall accuracy was 1.36 mm ± 0.53, which did not differ between the 2 types of CT scanners (1.39 mm ± 0.54 [moving patient table CT] vs 1.33 mm ± 0.52 [moving gantry CT]; P = .54) and was not significantly affected by the needle angulation and insertion depth. The accuracy for the porcine model was 9.09 mm ± 4.21.ConclusionsRobot-assisted needle insertion using the ANT-C robotic device was feasible and accurate for targeting multiple markers in a phantom model.  相似文献   

3.
PurposeTo evaluate safety and efficacy of CT hepatic arteriography compared with conventional CT fluoroscopy guidance in percutaneous radiofrequency (RF) and microwave (MW) ablation to treat colorectal liver metastases (CRLM).Materials and MethodsThis single-center comparative, retrospective study analyzed data of 108 patients treated with 156 percutaneous ablation procedures (42 CT fluoroscopy guidance [25 RF ablation, 17 MW ablation]; 114 CT hepatic arteriography guidance [18 RF ablation, 96 MW ablation]) for 260 CRLM between January 2009 and May 2019. Local tumor progression-free survival (LTPFS) was assessed using univariate and multivariate Cox proportional hazard regression analyses. LTPFS and overall survival (OS) were estimated using the Kaplan-Meier method.ResultsThere were no complications related to the transarterial catheter procedure. CT hepatic arteriography proved superior to CT fluoroscopy regarding 2-year LTPFS (18/202 [8.9%] vs 19/58 [32.8%]; P < .001, respectively). CT hepatic arteriography versus CT fluoroscopy (hazard ratio = 0.28; 95% confidence interval, 0.15–0.54; P < .001) and MW ablation versus RF ablation (hazard ratio = 0.52; 95% confidence interval, 0.24–1.12; P = .094) were positive predictors for longer LTPFS. Multivariate analysis revealed that CT hepatic arteriography versus CT fluoroscopy (hazard ratio = 0.41; 95% confidence interval, 0.19–0.90; P = .025) was associated with a significantly superior LTPFS. OS was similar between the 2 cohorts (P = .3).ConclusionsWhile adding procedure time and marginal patient burden, transcatheter CT hepatic arteriography–guided ablation was associated with increased local disease control and superior LTPFS compared with conventional CT fluoroscopy. CT hepatic arteriography represents a safe and valid alternative to CT fluoroscopy, as it reduces the number of repeat ablations required without adding risk or detrimental effect on survival.  相似文献   

4.
PurposeTo evaluate the feasibility of using dual-energy computed tomography (CT) and theranostic cesium hydroxide (CsOH) for image guidance of thermochemical ablation (TCA) in a rabbit VX2 tumor model.Materials and MethodsIn vivo experiments were performed on New Zealand white rabbits, where VX2 tumor fragments (0.3 mL) were inoculated into the right and left flanks (n = 16 rabbits, 32 tumors). Catheters were placed in the approximate center of 1- to 2-cm diameter tumors under ultrasound guidance. TCA was delivered in 1 of 3 treatment groups: untreated control, 5-M TCA, or 10-M TCA. The TCA base reagent was doped with 250-mM CsOH. Dual-energy CT was performed before and after TCA. Cesium (CS)-specific images were postprocessed on the basis of previous phantom calibrations to determine Cs concentration. Line profiles were drawn through the ablation center. Twenty-four hours after TCA, subjects were euthanized, and the resulting damage was evaluated with histopathology.ResultsCs was detected in 100% of treated tumors (n = 21). Line profiles indicated highest concentrations at the injection site and decreased concentrations at the tumor margins, with no Cs detected beyond the ablation zone. The maximum detected Cs concentration ranged from 14.39 to 137.33 mM. A dose-dependent trend in tissue necrosis was demonstrated between the 10-M TCA and 5-M TCA treatment groups (P = .0005) and untreated controls (P = .0089).ConclusionsDual-energy CT provided image guidance for delivery, localization, and quantification of TCA in the rabbit VX2 model.  相似文献   

5.
PurposeTo test the hypothesis that interventional radiologists (IRs) and neurointerventional (NI) physicians have similar outcomes of endovascular stroke thrombectomy (EVT), which could be used to improve the availability of thrombectomy.Materials and MethodsEight hospitals providing EVT performed by IRs and NI physicians at the same institution submitted sequential retrospective data limited to the era of modern devices. Good clinical outcomes (a 90-day modified Rankin score [mRS] of 0–2) and technically successful revascularization (a modified thrombolysis in cerebral infarction score of ≥2b) were compared between the specialties after adjusting for treating hospital, patient age, stroke severity, Alberta stroke program early computed tomography score, time from symptom onset to door, and clot location. Propensity score matching was used to compare the outcomes. A total of 1,009 patients were evaluated (622 treated by IRs and 387 treated by NI physicians).ResultsThe median time from stroke onset to puncture was 245 versus 253 minutes (P = .49), the technically successful revascularization rate was 81.8% versus 82.4% (P = .81), and the good clinical outcome rate was 45.5% versus 50.1% (P = .16). After adjusting, the physician specialty was not a significant predictor of good clinical outcomes (odds ratio, 1.028; 95% confidence interval, 0.760–1.390; P = .86). After matching, an mRS of 0–2 was present in 47.7% of IR treated patients and 51.1% of NI treated patients (P = .366).ConclusionsThere were no significant differences in the successful revascularization rate and good clinical outcomes between IRs and NI physicians. The outcomes of EVT performed by IRs were similar to those of EVT performed by NI physicians, as determined using previously published trials and registries. This may be useful for addressing coverage and access to stroke interventions.  相似文献   

6.
PurposeTo compare electromagnetic navigation (EMN) with computed tomography (CT) fluoroscopy for guiding percutaneous biopsies in the abdomen and pelvis.Materials and MethodsA retrospective matched-cohort design was used to compare biopsies in the abdomen and pelvis performed with EMN (consecutive cases, n = 50; CT-Navigation; Imactis, Saint-Martin-d’Hères, France) with those performed with CT fluoroscopy (n = 100). Cases were matched 1:2 (EMN:CT fluoroscopy) for target organ and lesion size (±10 mm).ResultsThe population was well-matched (age, 65 vs 65 years; target size, 2.0 vs 2.1 cm; skin-to-target distance, 11.4 vs 10.7 cm; P > .05, EMN vs CT fluoroscopy, respectively). Technical success (98% vs 100%), diagnostic yield (98% vs 95%), adverse events (2% vs 5%), and procedure time (33 minutes vs 31 minutes) were not statistically different (P > .05). Operator radiation dose was less with EMN than with CT fluoroscopy (0.04 vs 1.2 μGy; P < .001), but patient dose was greater (30.1 vs 9.6 mSv; P < .001) owing to more helical scans during EMN guidance (3.9 vs 2.1; P < .001). CT fluoroscopy was performed with a mean of 29.7 tap scans per case. In 3 (3%) cases, CT fluoroscopy was performed with gantry tilt, and the mean angle out of plane for EMN cases was 13.4°.ConclusionsPercutaneous biopsies guided by EMN and CT fluoroscopy were closely matched for technical success, diagnostic yield, procedure time, and adverse events in a matched cohort of patients. EMN cases were more likely to be performed outside of the gantry plane. Radiation dose to the operator was higher with CT fluoroscopy, and patient radiation dose was higher with EMN. Further study with a wider array of procedures and anatomic locations is warranted.  相似文献   

7.
PurposeTo investigate an augmented reality (AR)–guided endovascular puncture to facilitate successful transjugular intrahepatic portosystemic shunt (TIPS).Materials and MethodsAn AR navigation system for TIPS was designed. Three-dimensional (3D) liver models including portal and hepatic vein anatomy were extracted from preoperative CT images. The 3D models, intraoperative subjects, and electromagnetic tracking information of the puncture needles were integrated through the system calibration. In the AR head-mounted display, the 3D models were overlaid on the subjects, which was a liver phantom in the first phase and live beagle dogs in the second phase. One life-size liver phantom and 9 beagle dogs were used in the experiments. Imaging after puncture was performed to validate whether the needle tip accessed the target hepatic vein successfully.ResultsEndovascular punctures of the portal vein of the liver phantom were repeated 30 times under the guidance of the AR system, and the puncture needle successfully accessed the target vein during each attempt. In the experiments of live canine subjects, the punctures were successful in 2 attempts in 7 beagle dogs and in 1 attempt in the remaining 2 dogs. The puncture time of needle from hepatic vein to portal vein was 5–10 s in the phantom experiments and 10–30 s in the canine experiments.ConclusionsThe feasibility of AR-based navigation facilitating accurate and successful portal vein access in preclinical models of TIPS was validated.  相似文献   

8.
PurposeTo determine risk factors (RFs) for hemorrhagic adverse events (AEs) associated with percutaneous transhepatic biliary drainage (PTBD) and to develop a risk assessment model.Materials and MethodsThis was a multicenter, prospective, case control study between 2015 and 2020. Adults with an indication for PTBD were included. Patients who had undergone recent previous drainage procedures were excluded. Multiple variables were controlled. The exposure variables were the number of capsular punctures and passes (using the same puncture). A multivariate analysis was performed (logistic regression analysis).ResultsA total of 304 patients (mean age, 63 years ± 14 [range, 23–87 years]; female, 53.5%) were included. Hemorrhagic AEs occurred in 13.5% (n = 41) of the patients, and 3.0% (n = 9) of the cases were severe. Univariate analysis showed that the following variables were not associated with hemorrhagic AEs: age, sex, bilirubin and hemoglobin levels, type of pathology, portal hypertension, location of vascular punctures, ascites, nondilated bile duct, intrahepatic tumors, catheter features, blood pressure, antiplatelet drug use, and tract embolization. Multivariate analysis showed that number of punctures (odds ratio [OR], 2.5; P = .055), vascular punctures (OR, 4.1; P = .007), fatty liver or cirrhosis (OR, 3.7; P = .021), and intrahepatic tumor obstruction (Bismuth ≥ 2; OR, 2.4; P = .064) were associated with hemorrhagic AEs. Patients with corrected coagulopathies had fewer hemorrhagic AEs (OR, ?5.5; P = .026). The predictability was 88.2%. The area under the curve was 0.56 (95% confidence interval, 0.50–0.61).ConclusionsPreprocedural and intraprocedural RFs were identified in relation to hemorrhage with PTBD. AE risk assessment information may be valuable for prediction and management of hemorrhagic AEs.  相似文献   

9.
PurposeTo assess pulmonary arteriovenous malformation (PAVM) growth among patients with untreated PAVMs using imaging from long-term follow-up per hereditary hemorrhagic telangiectasia international guidelines.Materials and MethodsAnalysis included 88 untreated PAVMs from 21 patients (6 male;15 female; mean age at presentation 47 y; range, 12–68 y). Two CT studies with the longest interval between were evaluated (mean 8.4 y; median 8.8 y; range, 3.1–14.1 y). Measurement of feeding artery diameter and anteroposterior (AP) and mediolateral (ML) sac dimensions for each PAVM was performed separately by 2 radiologists blinded to patient and CT order. Statistical analysis was performed to determine change in size between earliest and follow-up imaging.ResultsMean feeding artery diameter, AP sac dimension, and ML sac dimension were 1.4 mm (range, 0.8–3.7 mm), 4.3 mm (range, 2.1–11.1 mm), and 4.1 mm (range, 1.8–9.2 mm) on earliest imaging and 1.4 mm (range, 0.9–2.6 mm), 4.5 mm (range, 2.2–12.2 mm), and 4.3 mm (range, 2.0–9.6 mm) on follow-up. Model-based mean analysis showed no statistically significant change in dimension of any variable between earliest and follow-up imaging. Secondary analysis including age also found no statistically significant difference (feeding diameter, P = .09; AP sac dimension, P = .9; ML sac dimension, P = .1). Analysis including time between measurements found no significant relationship between change in variables and time (feeding artery diameter, P = .4; AP sac dimension, P = .3; ML sac dimension, P = .06).ConclusionsUntreated PAVMs grew slowly, if at all, in a near-decade span, and any demonstrated growth was minimal. These findings challenge the current recommendation of 3- to 5-year CT follow-up.  相似文献   

10.
PurposeTo evaluate the ability of hand motion analysis using conventional and new motion metrics to differentiate between operators of varying levels of experience for central venous access (CVA) and liver biopsy (LB).Materials and MethodsIn the CVA task, 7 interventional radiologists (experts), 10 senior trainees, and 5 junior trainees performed ultrasound-guided CVA on a standardized manikin; 5 trainees were retested after 1 year. In the LB task, 4 radiologists (experts) and 7 trainees biopsied a lesion on a manikin. Conventional motion metrics (path length and task time), a refined metric (translational movements), and new metrics (rotational sum and rotational movements) were calculated.ResultsIn the CVA task, experts outperformed trainees on all metrics (P < .02). Senior trainees required fewer rotational movements (P = .02), translational movements (P = .045), and time (P = .001) than junior trainees. Similarly, on 1-year follow-up, trainees had fewer translational (P = .02) and rotational (P = .003) movements with less task time (P = .003). The path length and rotational sum were not different between junior and senior trainees or for trainees on follow-up. Rotational and translational movements had greater area under the curve values (0.91 and 0.86, respectively) than the rotational sum (0.73) and path length (0.61). In the LB task, experts performed the task with a shorter path length (P = .04), fewer translational (P = .04) and rotational (P = .02) movements, and less time (P < .001) relative to the trainees.ConclusionsHand motion analysis using translational and rotational movements was better at differentiating levels of experience and improvement with training than the conventional metric of path length.  相似文献   

11.
PurposeThe purpose of this study was to present the institutional experience of performing endoscopy, cholangiography, and biliary interventions through the modified Hutson loop by interventional radiology.Materials and MethodsA total of 61 of 64 modified Hutson loop access procedures were successful. This single-center retrospective study included 61 successful procedures of biliary interventions using existing modified Hutson loops (surgically affixed subcutaneous jejunal limb adjacent to biliary anastomosis or anastomoses) for diagnostic or therapeutic purposes in 21 patients. Seventeen of 21 patients (81%) had undergone liver transplantation. Indications included biliary strictures (n = 18) and biliary leaks (n = 3). The clinical success and complications were evaluated.ResultsThere were 3 of 26 modified Hutson loop retrograde biliary intervention failures (12%) before introduction of endoscopy and no failures (0 of 38 [0%]) subsequently (P = .06). Endoscopy or cholangioscopy was performed in 19 procedures by interventional radiologists. Retrograde biliary interventions included diagnostic cholangiography (n = 26), cholangioplasty (n = 25), stent placement (n = 29), stent retrieval (n = 25), and biliary drainage catheter placement (n = 5). No procedure-related mortality occurred. There was 1 major complication (duodenal perforation) (1.6%) and 12 minor complications (19%). In the 9 patients undergoing therapeutic interventions for biliary strictures, there was a significant decrease in median alkaline phosphatase (288.5 to 174.5 U/L; P = .03). There was a trend toward decrease in median bilirubin levels (1.7 to 1 mg/dL; P = .06) at 1 month post-intervention.ConclusionsThe modified Hutson loop provided interventional radiologists a safe and effective alternative access to manage biliary complications in patients with biliary-enteric anastomoses. Introduction of the endoscope in interventional radiology has improved the success rate of these procedures.  相似文献   

12.
PurposeTo evaluate the feasibility and accuracy of a radiation-free implantation of a thoracic aortic stent graft employing fiberoptic and electromagnetic tracking in an anthropomorphic phantom.Materials and MethodsAn anthropomorphic phantom was manufactured based on computed tomography (CT) angiography data from a patient. An aortic stent graft application system was equipped with a fiber Bragg gratings and 3 electromagnetic sensors. The stent graft was navigated in the phantom by 3 interventionalists using the tracking data generated by both technologies. One implantation procedure was performed. The technical success of the procedure was evaluated using digital subtraction angiography and CT angiography (before and after the intervention). Tracking accuracy was determined at various anatomical landmarks based on separately acquired fluoroscopic images. The mean/maximum errors were measured for the stent graft application system and the tip/end of the stent graft.ResultsThe procedure resulted in technical success with a mean error below 3 mm for the entire application system and <2 mm for the position of the tip of the stent graft. Navigation/implantation and handling of the device were rated sufficiently accurate and on par with comparable, routinely used stent graft application systems.ConclusionsThe study demonstrates successful stent graft implantation during a thoracic endovascular aortic repair procedure employing advanced guidance techniques and avoiding fluoroscopic imaging. This is an essential step in facilitating the implantation of stent grafts and reducing the health risks associated with ionizing radiation during endovascular procedures.  相似文献   

13.
PurposeTo show that a deep learning (DL)–based, automated model for Lipiodol (Guerbet Pharmaceuticals, Paris, France) segmentation on cone-beam computed tomography (CT) after conventional transarterial chemoembolization performs closer to the “ground truth segmentation” than a conventional thresholding-based model.Materials and MethodsThis post hoc analysis included 36 patients with a diagnosis of hepatocellular carcinoma or other solid liver tumors who underwent conventional transarterial chemoembolization with an intraprocedural cone-beam CT. Semiautomatic segmentation of Lipiodol was obtained. Subsequently, a convolutional U-net model was used to output a binary mask that predicted Lipiodol deposition. A threshold value of signal intensity on cone-beam CT was used to obtain a Lipiodol mask for comparison. The dice similarity coefficient (DSC), mean squared error (MSE), center of mass (CM), and fractional volume ratios for both masks were obtained by comparing them to the ground truth (radiologist-segmented Lipiodol deposits) to obtain accuracy metrics for the 2 masks. These results were used to compare the model versus the threshold technique.ResultsFor all metrics, the U-net outperformed the threshold technique: DSC (0.65 ± 0.17 vs 0.45 ± 0.22, P < .001) and MSE (125.53 ± 107.36 vs 185.98 ± 93.82, P = .005). The difference between the CM predicted and the actual CM was 15.31 mm ± 14.63 versus 31.34 mm ± 30.24 (P < .001), with lesser distance indicating higher accuracy. The fraction of volume present ([predicted Lipiodol volume]/[ground truth Lipiodol volume]) was 1.22 ± 0.84 versus 2.58 ± 3.52 (P = .048) for the current model’s prediction and threshold technique, respectively.ConclusionsThis study showed that a DL framework could detect Lipiodol in cone-beam CT imaging and was capable of outperforming the conventionally used thresholding technique over several metrics. Further optimization will allow for more accurate, quantitative predictions of Lipiodol depositions intraprocedurally.  相似文献   

14.
PurposeTo compare the diagnostic accuracy and adverse event rates of intravascular ultrasound (US)-guided transvenous biopsy (TVB) versus those of computed tomography (CT)-guided percutaneous needle biopsy (PNB) for retroperitoneal (RP) lymph nodes.Materials and MethodsIn this single-institution, retrospective study, 32 intravascular US-guided TVB procedures and a sample of 34 CT-guided PNB procedures for RP lymph nodes where targets were deemed amenable to intravascular US-guided TVB were analyzed. Procedural metrics, including diagnostic accuracy, defined as diagnostic of malignancy or a clinically verifiable benign result, and adverse event rates were compared.ResultsThe targets of intravascular US-guided TVB were primarily aortocaval (47%, 15/32) or precaval (34%, 11/32), whereas those of CT-guided PNB were primarily right pericaval (44%, 15/34) or retrocaval (44%, 15/34) (P < .001). The targets of intravascular US-guided TVB averaged 2.4 cm in the long axis (range, 1.3–3.7 cm) compared with 2.9 cm (range, 1.4–5.7 cm) for those of CT-guided PNB (P = .02). There was no difference in the average number of needle passes (3.8 for intravascular US-guided TVB vs 3.9 for CT-guided PNB; P = .68). The diagnostic accuracy was 94% (30/32) and the adverse event rate was 3.1% (1/32) for intravascular US-guided TVB, similar to those of CT-guided PNB (accuracy, 91% [31/34]; adverse event rate, 2.9% [1/34]).ConclusionsIntravascular US-guided TVB had a diagnostic accuracy and adverse event rate similar to CT-guided PNB for RP lymph nodes, indicating that intravascular US-guided TVB may be as safe and effective as conventional biopsy approaches for appropriately selected targets.  相似文献   

15.
PurposeTo evaluate the clinical safety and efficacy of EASYX, a new nonadhesive precipitating liquid embolic agent based on a polyvinyl alcohol ether polymer labeled with iodine molecules, for peripheral embolization.Materials and MethodsThis open-label prospective multicenter study was conducted on 50 consecutive patients treated with embolization using EASYX in 3 academic hospitals from April 2018 to July 2019. Indications for embolization were symptomatic varicocele (n = 15), type II endoleak (n = 8), acute hemorrhage (n = 16), portal vein embolization (PVE; n = 9), or angiomyolipoma (AML; n = 2). Patient characteristics, technical and clinical success rates, pain at injection, and satisfaction of the interventional radiologists were assessed. Follow-up imaging was performed using ultrasound for varicoceles (at 1 month) and computed tomography (CT) for the other indications (at 3 or 6 months).ResultsThe immediate technical success rate was 98%. The clinical success rates were 100% for acute hemorrhage and type II endoleaks, 89% for PVE, 86% for varicoceles, and 50% for AMLs. Patients who underwent PVE showed significant hypertrophy of the future liver remnant at follow-up (P < .001), and 55.6% of patients proceeded to hepatectomy. The absence of artifacts on imaging allowed improved monitoring of the aneurysmal sac in patients with type II endoleaks. The satisfaction rate of the interventional radiologists was >90% for 5 of 7 items.ConclusionsEASYX as a novel copolymer liquid embolic agent was safe and efficient for peripheral embolization. The absence of tantalum allowed reduced CT artifacts on imaging follow-up, which was especially useful in patients with type II endoleaks.  相似文献   

16.
ObjectiveTo assess the effectiveness of intra-articular injection of bone marrow concentrate (BMC) under ultrasound (US) guidance in the treatment of patellofemoral osteoarthritis (OA), with clinical and volumetric magnetic resonance (MR) imaging follow-up.MethodsThis retrospective study included 96 consecutive patients referred for US-guided intra-articular injection of BMC for symptomatic patellofemoral OA for which conservative treatment had failed. A control group of 21 patients with symptomatic patellofemoral OA was included for comparison. Data on International Knee Documentation Committee (IKDC), Visual Analog Scale (VAS), and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores as well as volumetric MR imaging (using T2 mapping sequence) were collected before and 12 months after injection, and the results were compared.ResultsNo technical adverse events were noted during bone marrow aspiration, BMC preparation, or intra-articular injection of BMC. No clinical adverse events were reported during long-term follow-up. All mean scores improved between baseline and 12 months after intra-articular injection of BMC (VAS 5.5 to 3.6, P < .0001; WOMAC 36.8 to 22.2, P < .0001; and IKDC 41.8 to 58.2, P < .0001). MR imaging at 1 year of follow-up after BMC treatment showed no statistically significant difference in hyaline cartilage volume compared with that at the baseline (P = .690), suggesting stabilization of the cartilage degradation process. In contrast, the group of untreated patients showed a significant decrease in the cartilage volume (P = .001), corresponding to a cartilage loss of 6.9%.ConclusionsThe results suggest that intra-articular injection of BMC under US guidance could be a promising option for the treatment of symptomatic patellofemoral OA and could promote the preservation of healthy residual cartilage volume.  相似文献   

17.
PurposeTo evaluate the radiation dose differences for intraprocedural computed tomography (CT) imaging between cone-beam CT and angio-CT acquired during transarterial radioembolization (TARE) therapies for hepatocellular carcinoma.Materials and MethodsA retrospective cohort of 22 patients who underwent 23 TARE procedures were selected. Patients were imaged in both cone-beam CT and angio-CT rooms as a part of their conventional treatment plan. Effective dose contributions from individual CT acquisitions as well as the cumulative dose contributions from procedural 3D imaging were evaluated. Angiography dose contributions were omitted. Cone-beam CT images were acquired on a C-arm Philips Allura system. Effective doses were evaluated by coupling previously published conversion factors (effective dose per dose-area product) to patient’s dose-area product meter readings after the procedure. Angio-CT images were acquired on a hybrid Canon Infinix-i Aquilion PRIME system. Effective doses from angio-CT scans were estimated using Radimetrics. Comparisons of a single patient’s dose differential between the 2 technologies were made.ResultsThe mean effective dose from a single CT scan was 6.42 mSv and 5.99 mSv in the cone-beam CT room and the angio-CT room, respectively (P = .3224), despite the greater field of view and average craniocaudal scan coverage in angio-CT. The mean effective dose summed across all CTs in a procedure was 12.89 mSv and 34.35 mSv in the cone-beam CT room and the angio-CT room, respectively (P = .0018).ConclusionsThe mean effective dose per CT scan is comparable between cone-beam CT and angio-CT when considered in direct comparison for a single patient.  相似文献   

18.
PurposeTo determine physician radiation exposure when using partial-angle computed tomography (CT) fluoroscopy (PACT) vs conventional full-rotation CT and whether there is an optimal tube/detector position at which physician dose is minimized.Materials and MethodsPhysician radiation dose (entrance air kerma) was measured for full-rotation CT (360°) and PACT (240°) at all tube/detector positions using a human-mimicking phantom placed in a 64-channel multidetector CT. Parameters included 120 kV, 20- and 40-mm collimation, and 100 mA. The mean, standard deviation, and increase/decrease in physician dose compared with a full-rotation scan were reported.ResultsPhysician radiation exposure during CT fluoroscopy with PACT was highly dependent on the position of the tube/detector during scanning. The lowest PACT physician dose was when the physician was on the detector side (center view angle 116°; ?35% decreased dose vs full-angle CT). The highest PACT physician dose was with the physician on the tube side (center view angle 298°; +34% increased dose vs full-angle CT), all doses P <.05 vs full-rotation CT.ConclusionsPartial-angle CT has the potential to both significantly increase or decrease physician radiation dose during CT fluoroscopy-guided procedures. The detector/tube position has a profound effect on physician dose. The lowest dose during PACT was achieved when the physician was located on the detector side (ie, distant from the tube). This data could be used to optimize CT fluoroscopy parameters to reduce physician radiation exposure for PACT-capable scanners.  相似文献   

19.
PurposeTo evaluate the role of computed tomography (CT) and CT angiography in guiding endovascular arteriography (EA) and embolization in hemodynamically (HD) stable and unstable patients with abdominal and/or pelvic (AP) trauma.Materials and MethodsA retrospective review was performed of patients with AP trauma who underwent EA with or without embolization (from January 2012 to August 2020) at an urban, level I trauma center. Patients aged <18 years or those undergoing EA outside of the abdomen and/or pelvis were excluded. Demographics, imaging findings, procedure length, contrast agent administration, laboratory values, and outcomes were compared on the basis of preprocedural imaging technique and hemodynamic status.ResultsA total of 190 patients with AP trauma underwent EA with or without embolization; among them, 123 were HD stable and underwent CT/CT angiography, whereas 67 were initially HD unstable and underwent operative management prior to EA. Of these patients, 38 underwent CT/CT angiography after hemodynamic stability was achieved prior to postoperative EA. The incidence of therapeutic embolization for arterial injury on EA was significantly higher in patients with preprocedural CT/CT angiography (65.8% vs 44.8%, P = .04). The positive and negative predictive values of CT angiography for arterial injury at the time of EA were 92.3% and 100%, respectively. Prior imaging was associated with a reduced contrast agent requirement at the time of EA and reduced transfusion requirement (P = .05 and P = .02). No significant differences were observed in adverse outcomes for patients undergoing preprocedural imaging.ConclusionsCT or CT angiography prior to EA for HD stable and unstable patients with AP trauma may improve the likelihood of therapeutic embolization and enable improved procedure metrics without increasing adverse outcomes.  相似文献   

20.
PurposeTo identify risk factors for clinical failure of uterine artery embolization (UAE) for postpartum hemorrhage (PPH), with particular attention to the uterine artery diameter.Materials and MethodsThis retrospective study included 47 patients who underwent UAE for PPH between January 1, 2010, and January 31, 2021. Technical success was defined as the completion of embolization of the arteries thought to be the cause of the bleeding. Clinical success was defined as no recurrent bleeding or need for additional therapeutic interventions. Univariate and multivariate analyses were performed to examine the risk factors associated with clinical failure of UAE.ResultsOf the 47 patients, 6 had recurrent bleeding. Of the 6 patients, 4 underwent hysterectomy, and 2 underwent repeat embolization. The clinical success rate was 87.2% (41/47), with no major adverse events such as uterine infarction or death. In univariate analysis, there were slight differences in multiparity (P = .115) and placental abruption (P = .128) and a significant difference in the findings of a narrow uterine artery on digital subtraction angiography (DSA) (P = .005). In multivariate analysis, only a narrow uterine artery on DSA was a significant factor (odds ratio, 18.5; 95% confidence interval, 2.5–134.8; P = .004).ConclusionsA narrow uterine artery on DSA was a risk factor for clinically unsuccessful UAE for PPH. It may be prudent to conclude the procedure only after it is ensured that vasospasm has been relieved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号