首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The capability of integrated flow cytometry to detect, in real time, moving cells in their natural states in vivo is demonstrated in a study of circulating red and white blood cells in lymph and blood flow of rat mesentery. This system combines dual pump-probe photothermal (PT) techniques, such as PT imaging, the PT thermolens method, and PT velocimetry, with high-resolution (up to 0.3 microm), high-speed (up to 1000 fps) transmission digital microscopy (TDM) and fluorescence imaging. All PT techniques are based on irradiation of cells in rat mesenteric microvessels with a spectrally tunable laser pulse (420 to 570 nm, 8 ns, 0.1 to 300 microJ) and on detection of temperature-dependent variations of the refractive index with a second continuous probe laser beam (633 nm, 1.4 mW). We focus on intravital monitoring of the integral PT response from single, moving, unlabeled cells (from 100 to 500 cells in one measurement). Potential in vivo applications of this new optical tool, called PT flow cytometry (PTFC), are discussed, including identification of selected cells with differences in natural absorptive properties and sizes, determination of laser-induced cell damage, estimation of flow velocity, and monitoring of circulating cells labeled with PT probes.  相似文献   

2.
We demonstrate 3-D optical coherence tomography using only 1-D mechanical scanning. This system uses the principle of Fourier domain optical coherence tomography for depth resolution, 1-D imaging for lateral vertical resolution, and mechanical scanning by a galvanometer for lateral horizontal resolution. An in vivo human fingerpad is investigated in three dimensions with an image size of 480 points (vertical) x 300 points (horizontal) x 1024 points (depth), which corresponds to 2.1 x 1.4 x 1.3 mm. The acquisition time for a single cross section is 1 ms and that for a single volume is 10 s. The system sensitivity is 75.6 dB at a probe beam power of 1.1 mW.  相似文献   

3.
We have developed and tested a GSO (gadolinium oxyorthosilicate) position-sensitive gamma detector which can be used with positron and single-photon radionuclides for imaging breast cancer or sentinel lymph node detection. Because GSO has a relatively good energy resolution for annihilation gammas as well as low energy gamma photons, and does not contain any natural radioisotopes, it can be used for positron imaging and lower energy single-photon imaging. The imaging detector consists of a GSO block, 2 inch square multi-channel position-sensitive photo-multiplier tube (PSPMT), and associated electronics. The size of a single GSO element was 2.9 mm x 2.9 mm x 20 mm and these elements were arranged into 15 x 15 matrixes to form a block that was optically coupled to the PSPMT. It was possible to separate all GSO crystals into a two-dimensional position histogram for annihilation gammas (511 keV) and low energy gamma photons (122 keV). The typical energy resolution was 24% FWHM and 37% FWHM for 511 keV and 122 keV gamma photons, respectively. For the positron imaging, coincidence between the imaging detector and a single gamma probe is measured. For the single-photon imaging, a tungsten collimator is mounted in front of the imaging detector. With this configuration, it was possible to image both positron radionuclides and low energy single-photon radionuclides. We measured spatial resolution and sensitivity as well as image quality of the developed imaging detector. Results indicated that the developed imaging detector has the potential to be a new and useful instrument for nuclear medicine.  相似文献   

4.
Cord factor--a mixture of 6,6'-diesters of alpha, alpha-D-trehalose with natural mycolic acids--which is purified from mycobacteria and other microorganisms, is known to have adjuvant activity as well as to enhance nonspecific resistance to infections and tumor development. In this work, trehalose 6,6'-dimycolate (TDM) was found to induce proliferative responses in rat thymus and lymph node cells. With the thymus cells, TDM responses were greater after removal of the adherent cell subpopulation. Consistent with this observation was the finding that addition of phagocytic cells purified from peritoneal or lymph node cell suspensions to nonadherent thymocytes abrogated the response of thymocytes to TDM. With the lymph node cells, the presence or removal of adherent cells had no major consequence on the TDM-induced proliferative response, since similar increases in deoxyribonucleic acid synthesis were observed with unfractionated and nonadherent cells. The difference between the sensitivities of thymus cells and lymph node cells to regulation by adherent cells indicated the existence of more than one type of TDM responder cell in rats. TDM also displayed marked stimulatory activity on thymus and lymph node cells from germ-free rats, ruling out the possibility that TDM might have triggered a specific, secondary, in vitro immune response. Expansion of a selected cell population(s) triggered by TDM may be involved in the manifestation of adjuvant activity and possibly other immunological properties of cord factor.  相似文献   

5.
Dendritic cell (DC) migration into the draining lymph nodes is critical for T cell priming. Here, we show that magnetic resonance imaging (MRI) can be used to visualize DC migration in vivo. We combined clinically approved small particles of iron oxide (SPIO) with protamine sulfate to achieve efficient uptake by murine bone marrow-derived DC. SPIO-DC were largely unaltered and after injection into the footpads of mice, they migrated into the T cell areas of the draining lymph nodes, which could be visualized by MRI. Distinct MRI signal reduction patterns correlated with the detection of SPIO-DC mainly within Thy-1.2+ B220- T cell areas, as confirmed by iron staining and immunohistology. Clear signal reduction patterns could still be observed with 1x10(6) injected SPIO-DC at high resolution, resulting in the detection of about 2000 DC. Control injections of homing-incompetent SPIO-DC derived from CCR7-/- mice or SPIO alone did not reach the T cell areas. Taken together, the results demonstrate that clinically approved contrast agents allow the non-invasive visualization of DC migration into the draining lymph node by MRI in vivo at high resolution. This protocol therefore also allows dynamic imaging of immune responses and MRI-based tracking of human DC in patients.  相似文献   

6.
Hirase H  Creso J  Buzsáki G 《Neuroscience》2004,128(1):209-216
Local hemodynamics of the cerebral cortex is the basis of modern functional imaging techniques, such as fMRIand PET. Despite the importance of local regulation of the blood flow, capillary level quantification of cerebral blood flow has been limited by the spatial resolution of functional imaging techniques and the depth penetration of conventional optical microscopy. Two-photon laser scanning microscopic imaging technique has the necessary spatial resolution and can image capillaries in the depth of the cortex. We have loaded the serum with fluorescein isothiocyanate dextran and quantified the flow of red blood cells (RBCs) in capillaries in layers 2/3 of the mouse somatosensory cortex in vivo. Basal capillary flux was quantified as approximately 28.9+/-13.6 RBCs/s (n=50, mean+/-S.D.) under ketamine-xylazine anesthesia and 26.7+/-16.0 RBCs/s (n=31) under urethane anesthesia. Focal interictal (epileptiform) activity was induced by local infusion of bicuculline methochloride in the cortex. We have observed that capillary blood flow increased as the cortical local field events developed into epileptiform in the vicinity of GABA receptor blockade (<300 microm from the administration site). Local blood flow in the interictal focus increased significantly (42.5+/-18.5RBCs/s, n=52) relative to the control conditions or to blood flow measured in capillaries at distant (>1mm from the focus) sites from the epileptic focus (27.8+/-12.9 RBCs/s, n=30). These results show that hyper-synchronized neural activity is associated with increased capillary perfusion in a localized cortical area. This volume is significantly smaller than the currently available resolution of the fMRI signal.  相似文献   

7.
内脏器官激光多谱勒血流灌注图象的显示   总被引:5,自引:0,他引:5  
张栋  马惠敏  李顺月  王淑友 《中国微循环》2006,10(2):147-149,i0004
目的显示内脏器官血流灌注和分布的图象,探讨激光多谱勒血流成像技术在内脏微循环检测中的价值。方法应用激光多谱勒血流灌注成像仪(LDPI),对大鼠和家兔腹部脏器(肝、脾、肾、膀胱、胃、大小肠和肠系膜等)的血流灌注进行扫描和血流图显示。结果在体内脏器官显像清晰,肝、肾、脾、膀胱等微循环血流的整体分布较均匀;而胃、肠系膜、回盲肠等激光多谱勒血流图上大血流线状显示极其显著;大鼠与家兔两种动物之间相同脏器血流图上的差异并不明显。结论LDPI能将内脏器官的微循环状态以图象的形式显示,该新技术方法在检测内脏血流方面将有一定的应用价值。  相似文献   

8.
One of the major limitations in the current set of techniques available to neuroscientists is a dearth of methods for imaging individual cells deep within the brains of live animals. To overcome this limitation, we developed two forms of minimally invasive fluorescence microendoscopy and tested their abilities to image cells in vivo. Both one- and two-photon fluorescence microendoscopy are based on compound gradient refractive index (GRIN) lenses that are 350-1,000 microm in diameter and provide micron-scale resolution. One-photon microendoscopy allows full-frame images to be viewed by eye or with a camera, and is well suited to fast frame-rate imaging. Two-photon microendoscopy is a laser-scanning modality that provides optical sectioning deep within tissue. Using in vivo microendoscopy we acquired video-rate movies of thalamic and CA1 hippocampal red blood cell dynamics and still-frame images of CA1 neurons and dendrites in anesthetized rats and mice. Microendoscopy will help meet the growing demand for in vivo cellular imaging created by the rapid emergence of new synthetic and genetically encoded fluorophores that can be used to label specific brain areas or cell classes.  相似文献   

9.
Visualizing the in vivo dynamics of individual donor cells after allogeneic hematopoietic stem cell transplantation (HSCT) will enable deeper understanding of the process of graft-versus-host disease (GVHD) and graft-versus-leukemia (GVL). In this study, using non-invasive in vivo fluorescence imaging of the ear pinna, we successfully visualized green fluorescent protein (GFP) donor cells at the single cell level in the skin. This imaging model enabled visualization of the movement of GFP cells into blood vessels in real time after allogeneic HSCT. At day 1, a few donor cells were detected, and the movement of donor cells in blood vessels was readily observed at day 4. Early donor cell infiltration into non-lymphoid tissue was increased by treatment with croton oil, as an inflammatory reagent. Treatment with dexamethasone, as an anti-inflammatory reagent, suppressed donor cell infiltration. The in vivo cellular fluorescence imaging model described here is a very useful tool for monitoring individual donor cells in real-time and for exploring immunomodulatory reagents for allogeneic HSCT, as well as for understanding the mechanism of GVHD.  相似文献   

10.
We report an accurate method for studying the functional dynamics of the beating embryonic zebrafish heart. The fast cardiac contraction rate and the high velocity of blood cells have made it difficult to study cellular and subcellular events relating to heart function in vivo. We have devised a dynamic three-dimensional acquisition, reconstruction, and analysis procedure by combining (1) a newly developed confocal slit-scanning microscope, (2) novel strategies for collecting and synchronizing cyclic image sequences to build volumes with high temporal and spatial resolution over the entire depth of the beating heart, and (3) data analysis and reduction protocols for the systematic extraction of quantitative information to describe phenotype and function. We have used this approach to characterize blood flow and heart efficiency by imaging fluorescent protein-expressing blood and endocardial cells as the heart develops from a tube to a multichambered organ. The methods are sufficiently robust to image tissues within the heart at cellular resolution over a wide range of ages, even when motion patterns are only quasiperiodic. These tools are generalizable to imaging and analyzing other cyclically moving structures at microscopic scales.  相似文献   

11.
While quantitative analysis of dynamic biological cell motions in vivo is of great biomedical interest, acquiring 3-D (plus time) information is difficult due to the lack of imaging tools with sufficient spatial and temporal resolution. A novel 3-D high-speed microscopic imaging system is developed to enable 3-D time series data acquisition, based on a defocusing technique (DDPIV). Depth coordinate Z is resolved by the triangular image patterns generated by a mask with three apertures forming an equilateral triangle. Application of this technique to microscale imaging is validated by calibration of targets spread over the image field. 1-microm fluorescent tracer particles are injected into the blood stream of 32 h post-fertilization developing zebrafish embryos to help describe cardiac cell motions. 3-D and velocity fields of cardiovascular blood flow and trajectories of heart-wall motions are obtained.  相似文献   

12.
Li R  Guo W  Yang B  Guo L  Sheng L  Chen G  Li Y  Zou Q  Xie D  An X  Chen Y  Tian W 《Biomaterials》2011,32(20):4525-4538
An essential aspect of tooth tissue engineering is the identification of suitable scaffolding materials to support cell growth and tissue regeneration. Treated dentin matrix (TDM) from a rat has recently been shown to be a suitable scaffold for rat dentin regeneration. However, due to species-specific differences, it remains unclear whether a similar fabrication method can be extended to human TDM and human dentin regeneration. Therefore, this present study explored the biological response to a human TDM (hTDM) created using a modified dentin treatment method. Various biological characteristics, including cell proliferation, cell migration, cell viability, and cytotoxity were investigated. To assess the inductive capacity of hTDM, dental follicle cells (DFCs) were combined with hTDM and were implanted in vivo for 8 weeks in a mouse model. The resulting grafts were studied histologically. The results showed hTDM released dentinogenic factors, indicating that hTDM could play a sustained role in odontogenesis. DFC attachment, growth, viability, and cytotoxicity on the surface of hTDM showed a notable improvement over those on calcium phosphate controls. Most importantly, in vivo hTDM induced and supported regeneration of complete dentin tissues, which expressed dentin markers DSP and DMP-1. As cells in and around the regenerated dentin were positive for human mitochondria, implanted DFCs and hTDM were responsible for the regenerated dentin tissues. In conclusion, hTDM is indicated as an ideal biomaterial for human dentin regeneration.  相似文献   

13.
Two-photon microscopy is a powerful method in biomedical research that allows functional and anatomical imaging at a subcellular resolution in vivo . The technique is seriously hampered by absorption and scattering of light by blood, which prevents imaging through large vessels. Here, we demonstrate in the rat cerebral cortex that blood replacement by perfluorocarbon emulsion, a compound also used in human critical care medicine, yields superior image quality, while preserving neuronal integrity. Shadows of large superficial vessels disappear completely and cells can be imaged underneath them. For the first time, it is possible to image complete populations of neurons and astrocytes in the upper layers of neocortex in vivo .  相似文献   

14.
Understanding the tumor microenvironment is critical to characterizing how cancers operate and predicting their response to treatment. We describe a novel, high-resolution coregistered photoacoustic (PA) and pulse echo (PE) ultrasound system used to image the tumor microenvironment. Compared to traditional optical systems, the platform provides complementary contrast and important depth information. Three mice are implanted with a dorsal skin flap window chamber and injected with PC-3 prostate tumor cells transfected with green fluorescent protein. The ensuing tumor invasion is mapped during three weeks or more using simultaneous PA and PE imaging at 25 MHz, combined with optical and fluorescent techniques. Pulse echo imaging provides details of tumor structure and the surrounding environment with 100-μm(3) resolution. Tumor size increases dramatically with an average volumetric growth rate of 5.35 mm(3)/day, correlating well with 2-D fluorescent imaging (R = 0.97, p < 0.01). Photoacoustic imaging is able to track the underlying vascular network and identify hemorrhaging, while PA spectroscopy helps classify blood vessels according to their optical absorption spectrum, suggesting variation in blood oxygen saturation. Photoacoustic and PE imaging are safe, translational modalities that provide enhanced depth resolution and complementary contrast to track the tumor microenvironment, evaluate new cancer therapies, and develop molecular contrast agents in vivo.  相似文献   

15.
Wu MC  Hasegawa BH  Dae MW 《Medical physics》2002,29(12):2830-2839
The increasing use of transgenic mice as models of human physiology and disease has motivated the development of dedicated in vivo imaging systems for anatomic and functional characterization of mice as an adjunct to or a replacement for established ex vivo techniques. We have developed a pinhole single photon emission computed tomography (SPECT) system for high resolution imaging of mice with cardiovascular imaging as the primary application. In this work, we characterize the system performance through phantom studies. The spatial resolution and sensitivity were measured from images of a line source and point source, respectively, and were reported for a range of object-to-pinhole distances and pinhole diameters. Tomographic images of a uniform cylindrical phantom, Defrise phantom, and grid phantom were used to characterize the image uniformity and spatial linearity. The uniform phantom image did not contain any ring or reconstruction artifacts, but blurring in the axial direction was evident in the Defrise phantom images. The grid phantom images demonstrated excellent spatial linearity. A novel phantom modeling perfusion of the left ventricle of a mouse was designed and built with perfusion defects of varying sizes to evaluate the system performance for myocardial perfusion imaging of mice. The defect volumes were measured from the pinhole SPECT images and correlated to the actual defect volumes calculated according to geometric formulas. Linear regression analysis produced a correlation coefficient of r = 0.995 (p < 0.001), demonstrating the feasibility for measurement of perfusion defect size in mice using pinhole SPECT. We have performed phantom studies to characterize the spatial resolution, sensitivity, image uniformity, and spatial linearity of the pinhole SPECT system. Measurement of the perfusion defect size is a valuable phenotypic assessment and will be useful for hypothesis testing in murine models of cardiovascular disease.  相似文献   

16.
Trehalose-6,6'-dimycolate (TDM), or cord factor, is a mycobacterial cell wall component that induces granuloma formation and proinflammatory cytokine production in vivo and in vitro. The purpose of this work was to better understand the mechanisms by which TDM promotes lung granuloma formation. This was accomplished by characterizing cytokine mRNA expression during TDM-induced alveolitis culminating in cohesive granuloma development. A single intravenous injection of TDM given to C57BL/6 mice produced lung granulomas that peaked in number 5 days after challenge and were nearly resolved by 14 days. mRNA in whole lung preparations was quantitated by bioluminescent RT-PCR. Tumor necrosis factor-alpha (TNF-alpha), interleukin-1beta (IL-1beta), and IL-6 were significantly elevated during granuloma development and decreased during granuloma resolution. There were no detectable changes in mRNA for interferon-y (IFN-y), IL-2, IL-4, IL-5, IL-10, and IL-12(p40). The level of TNF-alpha protein extracted from lung minces highly correlated with morphologic indices of granulomatous inflammation, indicating that it may be an important modulator of the inflammatory intensity induced by TDM. TDM may interact specifically with macrophages in vivo, as evidenced by induction of TNF-alpha, IL-1beta, and IL-6, but not IFN-gamma, protein in bone marrow-derived macrophages from C57BL/6 mice. TDM may therefore play an important role early in macrophage activation during the host granulomatous response to mycobacteria.  相似文献   

17.
We apply ultrasound-modulated optical tomography (UOT) to image ex-vivo methylene-blue-dyed sentinel lymph nodes embedded in 3.2-cm-thick chicken breast tissues. The UOT system is implemented for the first time using ring-shaped light illumination, intense acoustic bursts, and charge-coupled device (CCD) camera-based speckle contrast detection. Since the system is noninvasive, nonionizing, portable, relatively cost effective, and easy to combine with photoacoustic imaging and single element ultrasonic pulse-echo imaging, UOT can potentially be a good imaging modality for the detection of sentinel lymph nodes in breast cancer staging in vivo.  相似文献   

18.
Bioluminescent imaging (BLI) permits sensitive in vivo detection and quantification of cells specifically engineered to emit visible light. Three stable human tumor cell lines engineered to express luciferase were assessed for their tumorigenicity in subcutaneous, intravenous and spontaneous metastasis models. Bioluminescent PC-3M-luc-C6 human prostate cancer cells were implanted subcutaneously into SCID-beige mice and were monitored for tumor growth and response to 5-FU and mitomycin C treatments. Progressive tumor development and inhibition/regression following drug treatment were observed and quantified in vivo using BLI. Imaging data correlated to standard external caliper measurements of tumor volume, but bioluminescent data permitted earlier detection of tumor growth. In a lung colonization model, bioluminescent A549-luc-C8 human lung cancer cells were injected intravenously and lung metastases were monitored in vivo by whole animal imaging. Anesthetized mice were imaged weekly allowing a temporal assessment of in vivo lung tumor growth. This longitudinal study design permitted an accurate, real-time evaluation of tumor burden in the same animals over time. End-point bioluminescence measured in vivo correlated to total lung weight at necropsy. For a spontaneous metastatic tumor model, bioluminescent HT-29-luc-D6 human colon cancer cells implanted subcutaneously produced metastases to lung and lymph nodes in SCID-beige mice. Both primary tumors and micrometastases were detected by BLI in vivo. Ex vivo imaging of excised lung lobes and lymph nodes confirmed the in vivo signals and indicated a slightly higher frequency of metastasis in some mice. Levels of bioluminescence from in vivo and ex vivo images corresponded to the frequency and size of metastatic lesions in lungs and lymph nodes as subsequently confirmed by histology. In summary, BLI provided rapid, non-invasive monitoring of tumor growth and regression in animals. Its application to traditional oncology animal models offers quantitative and sensitive analysis of tumor growth and metastasis. The ability to temporally assess tumor development and responses to drug therapies in vivo also improves upon current standard animal models that are based on single end point data.  相似文献   

19.
The feasibility of ultrahigh resolution optical coherence tomography (UHR OCT) to image ex vivo and in vitro brain tissue morphology on a scale from single neuron cells to a whole animal brain was investigated using a number of animal models. Sub-2-microm axial resolution OCT in biological tissue was achieved at different central wavelengths by separately interfacing two state-of-the-art broad bandwidth light sources (titanium:sapphire, Ti:Al2O3 laser, lambdac=800 nm, Deltalambda=260 nm, Pout=50 mW and a fiber laser light source, lambdac=1350 nm, Deltalambda=470 nm, Pout=4 mW) to free-space or fiber-based OCT systems, designed for optimal performance in the appropriate wavelength regions. The ability of sub-2-microm axial resolution OCT to visualize intracellular morphology was demonstrated by imaging living ganglion cells in cultures. The feasibility of UHR OCT to image the globular structure of an entire animal brain as well as to resolve fine morphological features at various depths in it was tested by imaging a fixed honeybee brain. Possible degradation of OCT axial resolution with depth in optically dense brain tissue was examined by depositing microspheres through the blood stream to various depths in the brain of a living rabbit. It was determined that in the 1100 to 1600-nm wavelength range, OCT axial resolution was well preserved, even at depths greater than 500 microm, and permitted distinct visualization of microspheres 15 microm in diameter. In addition, the OCT image penetration depth and the scattering properties of gray and white brain matter were evaluated in tissue samples from the visual cortex of a fixed monkey brain.  相似文献   

20.
目的观察休克淋巴液对大鼠肺微血管内皮细胞(PMVEC)、肠系膜微淋巴管内皮细胞(MMLEC)、血管内皮生长因子(VEGF)表达的影响。方法无菌条件下复制大鼠重症失血性休克模型,引流休克时肠系膜淋巴液或收集门静脉血,同时收集正常淋巴液及门静脉血作为对照。以4%终浓度的处理因素与第3代PMVEC及MMLEC共同孵育6h,RT-PCR测定VEGF mRNA表达。结果不同处理因素与PMVEC及MMLEC孵育6h后,休克淋巴液组两种内皮细胞的VEGF mRNA表达均显著低于休克血浆组、正常淋巴液组、正常血浆组、胎牛血清(FBS)组、DMEM组;休克血浆组显著低于正常淋巴液组、正常血浆组、FBS组和DMEM组;其它组间无统计学差异。结论休克淋巴液可抑制内皮细胞的VEGF mRNA表达,且作用强于休克血浆。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号