首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Integration of dense HA rods into cortical bone   总被引:1,自引:0,他引:1  
HA ceramics are daily used in human surgery for bone healing partly due to their ability to integrate into bone. They are generally used under a macroporous form. The behaviour of dense HA after implantation is not so well known. We implanted within cortical sheep femurs dense pure HA-ceramics cylinders for periods from 2 weeks to 18 months. The samples were then sectioned and examined using back-scattered and secondary SEM and the interface was analysed using EDS. Histomorphometry measurement was also performed using an image analysis device coupled to a light microscope. It appeared that the cylinders were in direct contact with immature bone after three weeks. The bone maturated within three months. The implant surface showed moderate signs of resorption and some grains were released from the surface. The resorption zone was only a few microm thick after 18 months. The bulk ceramic contained default zones of increased porosity. They can constitute fragile zone when located close to the surface in which the resorption rate is increased. We conclude that dense pure HA is poorly degraded when implanted in cortical bone. Degradation depends on the defaults found on the ceramic structure and the remodelling of bone surrounding the material.  相似文献   

2.
Zinc is an essential trace element that has stimulatory effects on bone formation. Recently, we developed zinc-releasing calcium phosphate ceramics in order to add the pharmacologic effect of zinc to calcium phosphate ceramics. In our previous study, we showed that the optimum zinc content for promoting bone formation was 0.316 wt %. Therefore a zinc composite ceramic of zinc-containing beta-tricalcium phosphate and hydroxyapatite, with a zinc content of 0.316 wt %, was chosen for long-term implantation. Cylindrical rods of the zinc composite ceramic were implanted in rabbit femora for 2 to 60 weeks. Using computer-aided image analysis, a histomorphometric study was carried out to investigate bone formation and resorption around the implants. The control was a composite ceramic of beta-tricalcium phosphate and hydroxyapatite without zinc. The addition of zinc to the implant demonstrated both favorable and unfavorable effects on bone remodeling. The favorable effect was enhanced bone apposition to the implant surface, demonstrated by a significant increase in intramedullary bone apposition rate at 6 weeks and in cortical bone apposition rate at 24 and 60 weeks (p < 0.05). The unfavorable effect was increased bone resorption, demonstrated by a significant increase in medullary cavity area at 60 weeks (p < 0.05). In order to utilize the favorable effect and avoid the unfavorable effect of zinc, either a reduction in zinc content in the zinc composite ceramic or the selection of implantation sites that do not have excessive exposure to bone marrow are required.  相似文献   

3.
In vivo bone tissue response to a canasite glass-ceramic   总被引:1,自引:0,他引:1  
The aim of this study was to determine the biocompatibility and osteoconductive potential of a high-strength canasite glass ceramic. Glass-ceramic rods were produced using the lost-wax casting technique and implanted in the mid-shafts rabbit femurs. Implants were harvested at 4, 13 and 22 weeks and prepared for light and electron microscopy. Hydroxyapatite was used as a control material. Hydroxyapatite implants were surrounded by new mineralised bone tissue after 4 weeks of implantation. The amount of bone surrounding the implant increased slightly at 13 weeks. In contrast, canasite glass and glass ceramic implants were almost entirely surrounded by soft tissue during all the time periods. Close contact between bone and canasite glass-ceramic implant without the intervening fibrous tissue was observed in only a few regions. The canasite formulation evaluated was not osteoconductive and appeared to degrade in the biological environment. It was therefore concluded that the canasite formulation used was unsuitable for use as implant. Further work is required to improve the biocompatibility of these materials with bone tissue. It is possible that this could be achieved by reducing the solubility of the glass and glass ceramic.  相似文献   

4.
The in vivo evaluation, in New Zealand rabbits, of a sol-gel glass 70% CaO-30% SiO2 (in mol%) and a glass-ceramic obtained from thermal treatment of the glass, both bioactive in Kokubo's simulated body fluid (SBF), is presented. Femoral bone diaphyseal critical defects were filled with: (i) sol-gel glass cylinders, (ii) glass-ceramic cylinders, or (iii) no material (control group). Osteosynthesis was done by means of anterior screwed plates with an associate intramedullar Kirschner wire. Each group included 10 mature rabbits, 9 months old. Follow-up was 6 months. After sacrifice, macroscopic study showed healing of bone defects, with bone coating over the cylinders, but without evidence of satisfactory repair in control group. Radiographic study showed good implant stability and periosteal growth and bone remodelling around and over the filled bone defect. The morphometric study showed minimum evidences of degradation or resorption in glass-ceramic cylinders, maintaining its original shape, but sol-gel glass cylinders showed abundant fragmentation and surface resorption. An intimate union of the new-formed bone to both materials was observed. Mechanical study showed the higher results in the glass-ceramic group, whereas sol-gel glass and control group showed no differences. The minimum degradation of glass-ceramic cylinders suggests their application in critical bone defects locations of transmission forces or load bearing. The performance of sol-gel glass cylinders suggests their usefulness in locations where a quick resorption should be preferable, considering the possibility of serving as drug or cells vehicle for both of them.  相似文献   

5.
In this study bone regeneration between porous beta-tricalcium phosphate (Conduit TCP) and biphasic calcium phosphate ceramic (Biosel), with a hydroxyapatite/beta-TCP ratio of 75/25, was compared. The ceramic particles were implanted in sheep trabecular bone for 3, 12, and 26 weeks. Histomorphometrical analysis revealed that Conduit degraded significantly during time and only 36% of the material was left at 26 weeks implantation time. Biosel, in contrast, remained nearly intact. The degradation of Conduit was due to dissolution as well as cell-mediated. Biosel showed a high cellular intervention, although this material did not degrade. Both materials were osteoconductive. The amount of newly formed bone appeared greater in the Conduit group after 26 weeks (46% +/- 8% as compared to 37% +/- 8% for Biosel), but this difference was not significant. Bone distribution over the defect was homogeneous in Conduit, whereas Biosel showed significantly more bone in the periphery of the defect after 26 weeks in comparison to the center. In conclusion, both ceramics are biocompatible and osteoconductive. Degradation showed a difference in amount and in cellular events, with more degraded Conduit TCP with less cellular intervention as compared to Biosel.  相似文献   

6.
We investigated pellet-shaped implants prepared from biphasic calcium phosphate (BCP) ceramics with five different ratios of hydroxyapatite (HAP) to beta-tricalcium phosphate (beta-TCP) to evaluate these ceramics as bone substitutes. BCP ceramics impregnated with different doses of recombinant human bone morphogenetic protein 2 (rhBMP-2) (1, 5, and 10 microg) were used for experimental purposes and ceramics without rhBMP-2 were used for control. The pellets were implanted under the pericranium in adult Wistar male rats and were harvested 8 weeks after implantation. The retrieved pellets were then examined radiologically, histologically, and histomorphometrically. The results revealed that the pellets treated with rhBMP-2 exhibited new bone and bone marrow, whereas control pellets produced fibrous connective tissues. The formation of new bone induced by rhBMP-2 was dose dependent. The extent of bone and bone marrow formation and the degree of resorption of the ceramic particles were significantly higher in the pellets composed of 25% HAP-75% TCP. In this study, bioresorption of the ceramic produced favorable conditions for rhBMP-2-induced bone formation.  相似文献   

7.
The goal of the present study was to assess the effect of macropore size on the in vivo behavior of ceramic scaffolds. For that purpose, beta-tricalcium phosphate (beta-TCP) cylinders with four different macropore sizes (150, 260, 510, and 1220 microm) were implanted into drill hole defects in cancellous bone of sheep and their resorption behavior was followed for 6, 12 and 24 weeks. The scaffolds were evaluated for biocompatibility, and new bone formation was observed macroscopically, histologically and histomorphometrically. Histomorphometrical measurements were performed for the whole defect area and for the area subdivided into three concentric rings (outer, medial, and inner ring). All implants were tolerated very well as evidenced by the low amount of inflammatory cells and the absence of macroscopic signs of inflammation. Resorption proceeded fast since less than 5% ceramic remained at 24-week implantation. Hardly any effect of macropore size was observed on the in vivo response. Samples with an intermediate macropore size (510 microm) were resorbed significantly faster than samples with smaller macropore sizes (150 and 260 microm). However, this fast resorption was associated with a lower bone content and a higher soft tissue content. At 12 and 24 weeks, the latter differences had disappeared. Bone was more abundant in the outer ring than in the rest of the blocks at 6 weeks, and in the outer and medial ring compared to the inner ring at 12 weeks.  相似文献   

8.
We have developed a bioactive bone cement that consists of apatite and wollastonite containing glass-ceramic (AW-GC) powder and bisphenol-a-glycidyl dimethacrylate (Bis-GMA)-based resin. In this study, we made three types of composite (designated AWC, HAC, and TCPC) consisting of AW-GC, hydroxyapatite (HA,) or beta-tricalcium phosphate (beta-TCP) powder as the inorganic filler and Bis-GMA-based resin as the organic matrix. The proportion by weight of the filler mixed into the cement was 70%. Rectangular plates (10 x 15 x 2 mm) of each composite were made and abraded with 2000 alumina powder. These composites were implanted into tibial metaphyses of rabbits. Specimens were prepared 10 and 25 weeks after implantation and examined using transmission electron microscopy (TEM). AWC was in direct contact with bone 10 weeks after implantation, and AW-GC particles were partially absorbed at the surface. HAC was in contact with partially mineralized extracellular matrix 10 weeks after implantation. In TCPC-implanted specimens, randomly oriented mineral was observed 10 weeks after implantation; however, collagenous extracellular matrix rarely was observed. In 25-week specimens, AW-GC particles were completely absorbed and replaced by new bone, and there was no intervening soft tissue. Both HAC and TCPC were in contact with bone at 25 weeks. These results indicate that AWC has higher bioactivity than either HAC or TCPC.  相似文献   

9.
The response of bone cells to a newly developed porous beta-tricalcium phosphate composed of rod-shaped particles (RSbeta-TCP), beta-TCP composed of conventional non-rod-shaped particles (Cbeta-TCP), and hydroxyapatite (HA) was analyzed using in vivo implantation and in vitro osteoclastogenesis systems. Implantation of the materials into the rabbit femur showed that RSbeta-TCP and Cbeta-TCP were bioresorbable, but HA was not. Up to 12 weeks after the implantation, bioresorption of RSbeta-TCP and Cbeta-TCP accompanied by the formation of new bone occurred satisfactorily. At 24 weeks post-implantation, most of the RSbeta-TCP had been absorbed, and active osteogenesis was preserved in the region. However, in the specimens implanted with Cbeta-TCP, the amount of not only the implanted Cbeta-TCP but also the newly formed bone tissue decreased, and bone marrow dominated the region. The implanted HA was unbioresorbable throughout the experimental period. When osteoclasts were generated on RSbeta-TCP, Cbeta-TCP, or HA disks, apparent resorption lacunae were formed on the RSbeta-TCP and Cbeta-TCP, but not HA disks. Quantitation of the calcium concentration in the culture media showed an earlier and more constant release of calcium from RSbeta-TCP than Cbeta-TCP. These results showed that the microstructure of beta-TCP affects the activity of bone cells and subsequent bone replacement.  相似文献   

10.
Resorbable porous ceramic constructs, based on silicon-stabilized tricalcium phosphate, were implanted in critical-size defects of sheep tibias, either alone or after seeding with bone marrow stromal cells (BMSC). Only BMSC-loaded ceramics displayed a progressive scaffold resorption, coincident with new bone deposition. To investigate the coupled mechanisms of bone formation and scaffold resorption, X-ray computed microtomography (muCT) with synchrotron radiation was performed on BMSC-seeded ceramic cubes. These were analyzed before and after implantation in immunodeficient mice for 2 or 6 months. With increasing implantation time, scaffold thickness significantly decreased while bone thickness increased. The muCT data evidenced that all scaffolds showed a uniform density distribution before implantation. Areas of different segregated densities were instead observed, in the same scaffolds, once seeded with cells and implanted in vivo. A detailed muX-ray diffraction analysis revealed that only in the contact areas between deposited bone and scaffold, the TCP component of the biomaterial decreased much faster than the HA component. This event did not occur at areas away from the bone surface, highlighting coupling and cell-dependency of the resorption and matrix deposition mechanisms. Moreover, in scaffolds implanted without cells, both the ceramic density and the TCP:HA ratio remained unchanged with respect to the pre-implantation analysis.  相似文献   

11.
The aim of this work was to compare the osteogenicity of calcium phosphate ceramic granules with autologous bone graft in ectopic and orthotopic sites. Biphasic calcium phosphate (BCP) granules composed of hydroxyapatite (HA) and beta-tricalcium phosphate (beta-TCP) in a 60/40 ratio were sintered at 1050, 1125 and 1200 degrees C, producing different microporosities. Either BCP ceramic granules or autologous bone chips (n=7) were implanted into paraspinal muscles. Osteoinduction was not observed in either the BCP implants or autologous bone chips after 6 or 12 weeks in the ectopic sites. Hollow and bored polytetrafluoroethylene (PTFE) cylinders were filled with autologous bone, BCP granules or left empty, then implanted into critical-sized defects in femoral epiphyses. The PTFE cylinders left empty contained marrow and blood vessels but not mineralized bone, indicating that this model prevented bone ingrowth (0.56+/-0.43% at 12 weeks). Bone formation was observed in contact with the BCP1050 and BCP1125 granules in the femoral sites after 6 weeks. The amount of bone after 12 weeks was 5.6+/-7.3 and 9.6+/-6.6% for BCP1050 and BCP1125, respectively. Very little bone formation was observed with the BCP1200 implants (1.5+/-1.3% at 12 weeks). In both the ectopic and orthotopic sites, autologous bone chips were drastically resorbed (from 19.4+/-3.7% initially to 1.7+/-1.2% at 12 weeks). This study shows that synthetic bone substitutes may have superior stability and osteogenic properties than autologous bone grafts in critical-sized bone defects.  相似文献   

12.
A composite of poly-epsilon-caprolactone (PCL) loaded with gatifloxacine (GFLX), an antibiotic, and a beta-tricalcium phosphate (betaTCP) porous ceramic body was prepared by a solvent-free process in which no toxic solvent was used. GFLX mostly retained its bactericidal property after the processing. The composite of GFLX-loaded PCL and betaTCP ceramic released GFLX for 4 weeks in Hanks' balanced solution, and had sustained bactericidal activity against Streptococcus milleri and Bacteroides fragilis for at least 1 week. The composite of the GFLX-loaded PCL and betaTCP ceramic was implanted in an osteomyelitis lesion induced by S. milleri and B. fragilis in the rabbit mandible. The osteomyelitis lesion expanded in the mesial-distal direction when no composite was implanted or when the lesion was treated with debridement only. The composite of GFLX-loaded PCL and betaTCP showed efficacy in controlling infection at the bone defect formed by debridement, and supported bone tissue reconstruction at the bone defect. Twelve and 50 weeks after the implantation, the inflammation even disappeared. New bone formation was observed on the surface of the composite after 4 weeks. After 50 weeks, ingrowth of bone tissues with vascular channels was observed along the PCL and betaTCP interface, which indicated degradation of PCL and/or betaTCP ceramic at the ceramic/polymer interface followed by replacement by bone tissues. The GFLX concentrations in the serum and soft tissues were very low. Therefore, the composite of GFLX-loaded PCL and betaTCP ceramic would help arrest osteomyelitis when it is used in addition to intravenous antibiotic administration, and help new bone formation and osteoconduction.  相似文献   

13.
Recombinant human bone morphogenetic protein-2 (rhBMP-2) is known for its osteoinductive potential in bone tissue engineering. Calcium phosphate (Ca-P) cements are injectable, osteoconductive ceramic materials in which a macroporous structure can be induced during the setting reaction. In this study, the osteoinductive capability of rhBMP-2 loaded porous Ca-P cement was evaluated. Porous Ca-P cement discs were made and loaded with rhBMP-2 in vitro and implanted subcutaneously in the back of New Zealand white rabbits. The implantation period was either 2 or 10 weeks. Histological analysis of retrieved specimens revealed evident bone formation in the rhBMP-2 loaded Ca-P cement discs (pore fill: 18+/-6%) after 10 weeks of implantation. Bone formation occurred only in rhBMP-2 loaded porous Ca-P cement discs. Degradation of the Ca-P cement could not be confirmed after 10 weeks of implantation. The scaffold maintained its shape and stability during this time period. We conclude that porous Ca-P cement is a suitable carrier material for ectopic bone engineering.  相似文献   

14.
The aim of this study was to evaluate the influence of mechanical unloading on the repair of bone defects with implantation of biodegradable bone substitutes. Spherical granules of biodegradable hydroxyapatite composed of rod-shaped particles (RHA) or beta-tricalcium phosphate composed of rod-shaped particles (RTCP) were implanted into a bone defect created in the distal end of the right femur of 8-week-old Wistar rats. Two, 6, 10, and 22 weeks after implantation, part of the sciatic nerve in the thigh was resected and exposed to mechanical unloading for 2 weeks. Then, 4, 8, 12 and 24 weeks after implantation, repair of the bone defect was analyzed. As a control, the bone defect without implantation of ceramic granules was also analyzed. Both RHA and RTCP tended to be reduced, but the reduction was not obvious during the experimental period. At 12 and 24 weeks after implantation, the amount of newly formed bone in the animal implanted with RHA was significantly greater than that at 4 weeks after implantation, but that in the animal implanted with RTCP or without implantation was not significantly different. The number of osteoclasts in the region implanted with RHA was significantly larger than that of the region implanted with RTCP or without implantation at 12 and 24 weeks. The activities of alkaline phosphatase in osteoblasts and tartrate-resistant acid phosphatase in osteoclasts were remarkably increased in the bone defects with implantation compared with those in the bone defects without implantation. These results suggested that RHA stimulated osteogenesis and osteoclastogenesis even after 2 weeks of mechanical unloading, and that RHA could be expected to improve the repair of bone defects in patients under the condition of skeletal unloading.  相似文献   

15.
Long intercalated defects in canine ribs can be repaired successfully using porous beta-tricalcium phosphate (beta-TCP) cylinders, infused with a biodegradable polymer (poly D,L-lactic acid-polyethylene block copolymer) containing recombinant human bone morphogenetic protein-2 (rhBMP-2). We previously reported the successful regeneration of bony rib and periosteum defects using beta-TCP cylinders containing 400 microg of rhBMP-2. To reduce the amount of rhBMP-2 and decrease the time required for defect repair, we utilized a biodegradable polymer carrier, in combination with rhBMP-2 and the porous beta-TCP cylinders. An 8 cm long section of rib bone was removed and replaced with an implant comprised of the porous beta-TCP cylinders and the polymer containing 80 microg of rhBMP-2. Six weeks after surgical placement of the beta-TCP cylinder/polymer/BMP-2 implants, new rib bone with an anatomical configuration and mechanical strength similar to the original bone was regenerated at the defect site. The stiffness of the regenerated ribs at 3, 6, and 12 weeks after implantation of the composite implant was significantly higher than that of ribs regenerated by implantation of rhBMP-2/beta-TCP implants. Thus, addition of the synthetic polymer to the drug delivery system for BMP potentiated the bone-regenerating ability of the implant and enabled the formation of mechanically competent rib bone. This new method appears to be applicable to the repair of intercalated long bone defects often encountered in clinical practice.  相似文献   

16.
We have developed two types of polymethylmethacrylate (PMMA)-based bioactive bone cements containing bioactive glass beads (designated GBC) or apatite-wollastonite containing glass-ceramic powder (designated AWC) as the filler. A new method was used to evaluate the bone-cement interfacial strength of these bioactive bone cements. Two types of bioactive bone cements (GBC and AWC) and PMMA cement (CMW-1) were put in a frame attached to the smooth tibial metaphyseal cortex of the rabbit and polymerized in situ. The load required to detach the cement from the bone was measured at 4, 8, and 16 weeks after implantation. The interfacial tensile strength of GBC and AWC showed significantly higher values than PMMA cement from 4 weeks, and increased with time. For GBC, strength reached a maximum value of 12.39 +/- 1.79 kgf 16 weeks after implantation. Histological examination of rabbit tibiae up to 16 weeks demonstrated no intervening layer between the bioactive bone cements and the bone, whereas fibrous tissue was observed at the interface between the PMMA cement and the bone. From this study, we conclude that PMMA-based bioactive bone cements have a relatively higher adhesiveness at the interface than the conventionally used PMMA cement, showing potential as a promising alternative.  相似文献   

17.

In Japan, where allograft bone transplantation is not widespread, prospects for artificial bones are very high. Therefore, artificial bones with various compositions, porous structures, and porosities have been developed and employed for clinical use. Both Affinos® and Regenos® (made of beta-tricalcium phosphate and hydroxyapatite, respectively) are artificial bones with a unique unidirectional porous structure, in which pores with a diameter suitable for tissue penetration (25–300 μm) are aligned in one direction. The unidirectional porous structure allows rapid penetration of blood deep into the materials by a capillary effect. In animal experiments, Affinos® showed well-balanced resorption and was replaced with the host’s own bone from an early stage after implantation and new bone formation and remodeling were observed in the cortical bone and medullary cavity. When implanted for clinical situation, resorption from an early stage and good replacement with the patient’s own bone were also observed. Regenos® has an internal osteon-like material and a vascular-like structure that is maintained within the pores even after long-term implantation, as noted in an animal experiment. When implanted for clinical situation, good osteoconductivity was observed from an early stage of implantation. In addition, the material was observed to be slowly absorbed over time in some cases. We have discussed the beneficial effects of combining teriparatide and platelet-rich plasma impregnation and the potential prospects of these artificial bones.

  相似文献   

18.
The interface between bioactive ceramics and bone was studied by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The materials were apatite-wollastonite-containing glass ceramic (A-W.GC) as a representative surface-active ceramic, and calcite and beta-tricalcium phosphate (beta-TCP) as resorbable ceramics. Particles of these materials, ranging between about 100 microns and 300 microns in diameter, were implanted into rat tibiae, and specimens were prepared for observation at 8 weeks after implantation. Both SEM and TEM demonstrated that A-W.GC was bonded to bone through a thin Ca-P-rich layer consisting of fine apatite crystals apparently different from those of bone in shape, size, and orientation. Collagen fibers of the bone reached the surface of this layer, and chemical bonding between A-W.GC and the bone was speculated. Calcite and beta-TCP, on the other hand, made direct contact with the bone, and no apatite layer was present at the interface. The surfaces of the implants became rough due to degradation, and bone grew into the finest surface irregularities. However, we were unable to demonstrate any continuity of crystals between the resorbable implants and bone by high-resolution TEM. Accordingly, the bonding strength was considered to be mainly attributable to mechanical interlocking.  相似文献   

19.
Intertransverse process spinal fusion is a common surgical procedure for the treatment of spinal disorders. In the present study, a porous hydroxyapatite (HA)/beta-tricalcium phosphate (beta-TCP) ceramic was tested as graft material using a rabbit lumbar transverse process (L5-L6) fusion model. The porous ceramic blocks were implanted onto the dorsal decorticated surface of the lumbar transverse processes. The specimens were harvested at the seventh week after implantation. Histomorphological observation revealed that the integration of HA/beta-TCP with the host bone of the transverse process occurred by both cancellous bone formation and cartilage formation. Scanning electron microscopy-wavelength dispersive X-ray spectrometry examinations showed significant differences in calcium, phosphorus, and sulfur contents in the newly formed tissues and the porous HA/TCP implants. Nanoindentations were used to evaluate the intrinsic mechanical properties of the implants and the newly formed tissues. The Young's moduli of the newly formed cartilage, new cancellous bone, and HA/TCP, were 0.66 +/- 0.02 GPa, 2.36 +/- 0.50 GPa, and 10.2 +/- 1.21 GPa, respectively. Nanoindentation results revealed degradation of the porous ceramics and incomplete calcification of the new cancellous bone at the seventh week after implantation. Nanoindentation appeared to be a useful technique for assessing the mechanical status of spinal fusion in animal models.  相似文献   

20.
In order to study bone tissue interaction on calcium phosphate glass ceramics and on apatite ceramics, cylinders of standard size were implanted in the tibiae of rabbits. The materials were evaluated by radiography, light microscopy and microradiography. Apatite ceramics gave rise to a very close contact with new bone. Glass with an apatite surface evoked bone growth similar to that for apatite ceramics but with a loose contact while glass without an apatite surface gave rise to porous remodelling of new bone without close contact to the implant.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号