首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Adolescent idiopathic scoliosis (AIS) is a complex three-dimensional deformity of the spine requiring in severe cases invasive surgery. Here, we explore the potential of optical coherence tomography (OCT) as a guiding tool for novel fusionless minimally invasive spinal surgeries on an ex vivo porcine model. We show that OCT, despite its limited penetration depth, may be used to precisely locate structures such as growth plate, bone and intervertebral disk using relative attenuation coefficients. We further demonstrate a segmentation algorithm that locates growth plates automatically on en-face OCT reconstructions.  相似文献   

2.
Lipid-core atherosclerotic plaques are associated with disease progression, procedural complications, and cardiac events. Coronary plaque lipid can be quantified in optical coherence tomography (OCT) pullbacks by measurement of lipid arcs and lipid lengths; parameters frequently used in clinical research, but labor intensive and subjective to analyse. In this study, we investigated the ability of quantitative attenuation, derived from intravascular OCT, to detect plaque lipid. Lipid cores are associated with a high attenuation coefficient. We compared the index of plaque attenuation (IPA), a local quantitative measure of attenuation, to the manually measured lipid score (arc and length) on OCT images, and to the plaque characterization ex-vivo. We confirmed a correlation between the IPA and lipid scores (r2?>?0.7). Comparison to histology shows that high attenuation is associated with fibroatheroma, but also with macrophage presence. IPA is a robust, reproducible, and user-independent measure that facilitates quantification of coronary lipid, a potential tool in clinical research and in guiding percutaneous coronary intervention.  相似文献   

3.
Optical coherence tomography (OCT) is a growing imaging technique for real-time early diagnosis of digestive system diseases. As with other well-established medical imaging modalities, OCT requires validated imaging performance and standardized test methods for performance assessment. A major limitation in the development and testing of new imaging technologies is the lack of models for simultaneous clinical procedure emulation and characterization of healthy and diseased tissues. Currently, the former can be tested in large animal models and the latter can be tested in small animal disease models or excised human biopsy samples. In this study, a 23 cm by 23 cm optical phantom was developed to mimic the thickness and near-infrared optical properties of each anatomical layer of a human colon, as well as the surface topography of colorectal polyps and visual appearance compatible with white light endoscopy.  相似文献   

4.
5.
6.
BACKGROUND AND STUDY AIMS: Endoscopic optical coherence tomography (OCT) is an emerging medical technology capable of generating high-resolution cross-sectional imaging of tissue microstructure in situ and in real time. We assess the use and feasibility of OCT for real-time screening and diagnosis of Barrett's esophagus, and also review state-of-the-art OCT technology for endoscopic imaging. MATERIALS AND METHODS: OCT imaging was performed as an adjunct to endoscopic imaging of the human esophagus. Real-time OCT (13-microm resolution) was used to perform image-guided evaluation of normal esophagus and Barrett's esophagus. Beam delivery was accomplished with a 1-mm diameter OCT catheter-probe that can be introduced into the accessory channel of a standard endoscope. Different catheter-probe imaging designs which performed linear and radial scanning were assessed. Novel ultrahigh-resolution (1.1-microm resolution) and spectroscopic OCT techniques were used to image in vitro specimens of Barrett's esophagus. RESULTS: Endoscopic OCT images revealed distinct layers of normal human esophagus extending from the epithelium to the muscularis propria. In contrast, the presence of gland- and crypt-like morphologies and the absence of layered structures were observed in Barrett's esophagus. All OCT images showed strong correlations with architectural morphology in histological findings. Ultrahigh-resolution OCT techniques achieved 1.1-microm image resolution in in vitro specimens and showed enhanced resolution of architectural features. Spectroscopic OCT identified localized regions of wavelength-dependent optical scattering, enhancing the differentiation of Barrett's esophagus. CONCLUSIONS: OCT technology with compact fiberoptic imaging probes can be used as an adjunct to endoscopy for real-time image-guided evaluation of Barrett's esophagus. Linear and radial scan patterns have different advantages and limitations depending upon the application. Ultrahigh-resolution and spectroscopic OCT techniques improve structural tissue recognition and suggest future potential for resolution and contrast enhancements in clinical studies. A new balloon catheter-probe delivery device is proposed for systematic imaging and screening of the esophagus.  相似文献   

7.
A new concept for cancer screening has been preliminarily investigated. A cancer targeting agent loaded with a near-infrared (NIR) dye was topically applied on the tissue to highlight cancer-suspect locations and guide optical coherence tomography (OCT) imaging, which was used to further investigate tissue morphology at the micron scale. A pilot study on ApcMin mice has been performed to preliminarily test this new cancer screening approach. As a cancer-targeting agent, poly(epsilon-caprolactone) microparticles (PCLMPs), labeled with a NIR dye and functionalized with an RGD (argenine-glycine-aspartic acid) peptide, were used. This agent recognizes the α(ν)β(3) integrin receptor (ABIR), which is over-expressed by epithelial cancer cells. The contrast agent was administered topically in vivo in mouse colon. After incubation, the animals were sacrificed and fluorescence-guided high resolution optical coherence tomography (OCT) imaging was used to visualize colon morphology. The preliminary results show preferential staining of the abnormal tissue, as indicated by both microscopy and laser-induced fluorescence imaging, and OCT's capability to differentiate between normal mucosal areas, early dysplasia, and adenocarcinoma. Although very preliminary, the results of this study suggest that fluorescence-guided OCT imaging might be a suitable approach for cancer screening. If successful, this approach could be used by clinicians to more reliably diagnose early stage cancers in vivo.  相似文献   

8.
Background- Recent studies have reported development of neoatherosclerosis (NA) inside the stents several years after stent implantation. The aim of this study was to determine the predictors for NA using optical coherence tomography. Methods and Results- From a total of 1080 patients who underwent optical coherence tomography, we identified 179 stents in 151 patients in which the mean neointimal thickness was >100 μm. The presence of lipid-laden neointima or calcification inside the stents was defined as NA in the present study. Patient characteristics, stent type, and time since stent implantation (stent age) were compared between stents with or without NA. Univariable and multivariable logistic regression analyses were used to assess the independent predictors. In univariate analysis, stent age ≥48 months (Odds ratio [OR], 4.48; [95% CI 2.68-9.65]; P<0.001), drug-eluting stents (OR, 2.66; [95% CI, 1.38-5.16]; P=0.004), age ≥65 years (OR, 1.91; [95% CI, 1.05-3.44]; P=0.032), current smoking (OR, 2.30; [95% CI, 1.10-4.82]; P=0.024), chronic kidney disease (OR, 4.17; [95% CI, 1.42-12.23]; P=0.009), and angiotensin-converting enzyme inhibitors or angiotensin II receptor blockade use (OR, 0.42; [95% CI, 0.22-0.80]; P=0.008) were significant predictors. In multivariate analysis, stent age ≥48 months, all subtypes of drug-eluting stent, current smoking, chronic kidney disease, and angiotensin-converting enzyme inhibitors/angiotensin II receptor blockade use remained independent predictors for NA. Conclusions- In addition to the stent type and the stent age, patient characteristics, including current smoking, chronic kidney disease, and angiotensin-converting enzyme inhibitors/angiotensin II receptor blockade, were associated with the presence of NA. This result may support the importance of secondary prevention after stent implantation.  相似文献   

9.
10.
OBJECTIVE: To study the feasibility of noninvasive blood glucose monitoring using optical coherence tomography (OCT) technique in healthy volunteers. RESEARCH DESIGN AND METHODS: An OCT system with the wavelength of 1,300 nm was used in 15 healthy subjects in 18 clinical experiments. Standard oral glucose tolerance tests were performed to induce changes in blood glucose concentration. Blood samples were taken from the right arm vein every 5 or 15 min. OCT images were taken every 10-20 s from the left forearm over a total period of 3 h. The slope of the signals was calculated at the depth of 200-600 micro m from the skin surface. RESULTS: A total of 426 blood samples and 8,437 OCT images and signals were collected and analyzed in these experiments. There was a good correlation between changes in the slope of noninvasively measured OCT signals and blood glucose concentrations throughout the duration of the experiments. The slope of OCT signals changed significantly (up to 2.8% per 10 mg/dl) with variation of plasma glucose values. The good correlation obtained between the OCT signal slope and blood glucose concentration is due to the coherent detection of backscattered photons, which allows measurements of OCT signal from a specific tissue layer without unwanted signal from other tissue layers. CONCLUSIONS: This pilot study demonstrated the capability of the OCT technique to monitor blood glucose concentration noninvasively in human subjects. Further studies with a larger number of subjects including diabetic subjects are planned to validate these preliminary results.  相似文献   

11.
Clinical management of burn injuries depends upon an accurate assessment of the depth of the wound. Current diagnostic methods rely primarily on subjective visual inspection, which can produce variable results. In this study, spectroscopic optical coherence tomography was used to objectively evaluate burn injuries in vivo in a mouse model. Significant spectral differences were observed and correlated with the depth of the injury as determined by histopathology. The relevance of these results to clinical burn management in human tissues is discussed.OCIS codes: (170.6510) Spectroscopy, tissue diagnostics; (110.4500) Optical coherence tomography  相似文献   

12.
We describe an optical coherence tomography and vibrometry system designed for portable hand-held usage in the otology clinic on awake patients. The system provides clinically relevant point-of-care morphological imaging with 14-44 µm resolution and functional vibratory measures with sub-nanometer sensitivity. We evaluated various new approaches for extracting functional information including a multi-tone stimulus, a continuous chirp stimulus, and alternating air and bone stimulus. We also explored the vibratory response over an area of the tympanic membrane (TM) and generated TM thickness maps. Our results suggest that the system can provide real-time in vivo imaging and vibrometry of the ear and could prove useful for investigating otologic pathology in the clinic setting.  相似文献   

13.
Accurate measurement of the highly mineralized transparent surface layer that forms on caries lesions is important for diagnosis of the lesion activity because chemical intervention can slow or reverse the caries process via remineralization. Previous in-vitro and in-vivo studies have demonstrated that polarization-sensitive optical coherence tomography (PS-OCT) can nondestructively image the subsurface lesion structure and the highly mineralized transparent surface zone of caries lesions. The purpose of this study was to develop an approach to automatically process 3-dimensional PS-OCT images and to accurately assess the remineralization process in simulated enamel lesions. Artificial enamel lesions were prepared on twenty bovine enamel blocks using two models to produce varying degree of demineralization and remineralization. The thickness of the transparent surface layer and the integrated reflectivity of the subsurface lesion were measured using PS-OCT. The automated transparent surface layer detection algorithm was able to successfully detect the transparent surface layers with high sensitivity ( = 0.92) and high specificity ( = 0.97). The estimated thickness of the transparent surface layer showed a strong correlation with polarized light microscopy (PLM) measurements of all regions (R2 = 0.90). The integrated reflectivity, ΔR, and the integrated mineral loss, ΔZ, showed a moderate correlation (R2 = 0.32). This study demonstrates that PS-OCT can automatically measure the changes in artificial enamel lesion structure and severity upon exposure to remineralization solutions.OCIS codes: (170.4500) Optical coherence tomography, (170.1850) Dentistry, (170.0110) Imaging systems  相似文献   

14.
We assessed the feasibility and safety of frequency-domain optical coherence tomography (FD–OCT) in a variety of indications. We conducted a retrospective analysis of all FD–OCT examinations performed for research and clinical indications, including stable angina, acute coronary syndromes, diagnostic procedures and percutaneous coronary intervention (PCI), at the Satakunta Central Hospital (Pori, Finland) between August 12th 2009 and February 9th 2011. All pullbacks were screened for image quality. Data on complications and clinical implications of examinations was obtained from patient records. The mean age of the patients was 65.9 ± 10.9 years (81.7 % males). A total of 230 examinations were performed on 210 patients; 523 pullbacks were eventually attempted (519 successful). On average, 2.3 ± 1.1 pullbacks were performed, and 1.1 ± 0.4 vessels were scanned per examination. PCI was performed in 44.3 % of examinations. Radial access was used in 70.3 % of cases. Examination was successful in 202 (87.8 %) examinations. One patient died of heart failure later after PCI for acute myocardial infarction. No cases of major bleeding, myocardial infarction, contrast-induced nephropathy, or pericardial tamponade were encountered. Chest pain occurred in 10.9 % of examinations, minor bleeding in 4.8 %, and myocardial ischemia in 2.6 %. Femoral access was associated with fewer blood and decentration artefacts and a trend towards better image quality when compared to radial access, with no difference in complications. After the first 50 examinations, there appeared to be fewer artefacts in the subsequent examinations. The current study demonstrated that FD–OCT is feasible, with infrequent complications.  相似文献   

15.
To establish the accuracy of coronary computed tomography angiography (CTA) for in-scaffold quantitative evaluation with optical coherence tomography (OCT) as a reference. The translucent backbone of the bioresorbable scaffold allow us to evaluate non-invasively the coronary lumen with coronary CTA. In the ABSORB first-in-man studies, coronary CTA was shown to be feasible for quantitative luminal assessment. Nevertheless, a comparison with an intravascular modality with higher resolution has never been performed. In the ABSORB Cohort B trial, 101 patient with non-complex lesions were treated with the fully biodegradable vascular scaffold. For this analysis, all patients who underwent coronary CTA at 18 months and OCT within ±180 days were included. Coronary CTA and OCT data were analysed at an independent core laboratory for quantitative cross-sectional luminal dimensions. The primary objective was the accuracy and precision of coronary CTA for in-scaffold minimal lumen area assessment, with OCT as a reference. Among the 101 patients of the ABSORB Cohort B trial, 35 underwent both OCT and coronary CTA. The feasibility of quantitative evaluation was 74%. In the scaffolded segment, coronary CTA underestimated minimal lumen area by 9.8% (accuracy 0.39 mm2, precision 1.0 mm2, 95% limits of agreement ?1.71 to 2.50 mm2). A similar level of agreement was observed in the non-scaffolded segment. Compared to OCT, coronary CTA appears to be accurate for the estimation of in-scaffold luminal areas, with no difference compared to the non-scaffolded region.  相似文献   

16.
光学相干断层扫描(OCT)分辨率高且无创,是临床诊断眼底疾病的主要手段。深度学习(DL)具有高效、准确的特点,近年来在医疗领域迅速发展,并已在眼科取得一定成果。本文围绕基于DL的OCT辅助诊断常见眼底疾病研究进展进行综述。  相似文献   

17.
Electron-beam Computed Tomography (EBCT) has been used for years to quantify coronary artery calcification as a marker of coronary atherosclerosis. The aim of this study was to determine the diagnostic accuracy of a new scanner, the Multi-slice Spiral CT (MSCT), for the assessment of coronary calcification and to compare this new technique to EBCT. The study population consisted of 99 male patients, aged 60 ± 10 years with suspected or known coronary artery disease. With EBCT 40 axial slices, ECG-triggered (scan time = 100 ms, slice thickness = 3 mm), were acquired in one breath-hold (35 ± 5 s). For MSCT simultaneous acquisition of four axial slices (scan time = 250 ms, slice thickness = 2.5 mm), allowed the entire heart (48 slices) to be covered in one breath-hold of 25 ± 5 s. For quantification of coronary calcium the Volumetric Calcium Score (VCS) was calculated. There was an excellent correlation for the VCS (r = 0.994, p = 0.01, mean difference = 97 ± 115) between both scanners. Comparison of low (1–100), moderate (101–400), high (401–1000) and very high score values (>1000) showed no significant differences. The number of calcified lesions and densities were statistically not different. Mean variability of the two scans was 17%. The MSCT scanner is equivalent to EBCT for the determination and quantification of coronary calcium and can therefore be used for calcium screening. With application of the spiral mode technique further improvement in variability can be expected, thus allowing for follow-up studies to determine progression or regression of atherosclerosis with high accuracy.  相似文献   

18.
Background We sought to evaluate the role of adenosine myocardial contrast echocardiography (MCE) for the determination of functional relevance of coronary stenoses with intermediate angiographic severity and compared the results to single photon imaging (SPECT). We hypothezised that sole assessment of myocardial blood volume changes during adenosine on MCE would indicate functional stensosis relevance when accompanied by increased myocardial oxygen consumption (MVO2). Methods Fifty-seven patients with ≥1 coronary stenosis underwent adenosine MCE (ultraharmonic imaging) and exercise SPECT. On MCE, myocardial blood volume was assessed and constant or increased myocardial opacification during adenosine coupled with increased MVO2 was defined as normal and decreased opacification as abnormal. Results Rate–pressure product significantly increased during adenosine in all patients due to reflex tachycardia following mild hypotension, indicative of increased MVO2. Concordance between MCE and SPECT for the detection of reversible myocardial perfusion defects was 89% (κ = 0.83). Comparison of regions between rest and during adenosine as opposed to comparison to remote regions of the same stage was important for accurate assessment because concordance betweenn MCE and SPECT was less on separate assessment at rest (73%, κ = 0.40) compared to stress (91%, κ = 0.81, P < 0.05) mainly due to territories scored normal on SPECT and abnormal on MCE. Conclusions Assessment of myocardial blood volume changes during adenosine using MCE can be used for the determination of the functional relevance of coronary stenoses of intermediate angiographic severity if MVO2 is increased during adenosine.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号