首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Objective: The aim of this pilot study was to compare the early‐term osseointegration characteristics of standard (SLA) and modified sand‐blasted and acid‐etched (modSLA) implants in an experimental animal model. Material and methods: A total of 30 SLA and modSLA implants were placed to the tibiae of three sheep and the insertion torque value (ITV) and resonance frequency analysis (RFA) measurements were performed. RFA measurement was repeated on 3 and 6 weeks healed implants after which the animals were sacrificed for histomorphometric analysis. Bone‐to‐implant contact was assessed on the non‐decalcified sections. Six weeks healed implants were also subjected to the reverse torque test (RTT). Results were analyzed by the Friedman test, Kruskal–Wallis test and Spearman rank correlation test. Results: All implants reached to a strong primary stability with a mean 36.13 ± 2.47 and 35.47 ± 2.85 N/cm ITV. In the surgical stage, RFA values for SLA and modSLA implants were found to be 72.27 ± 3.17 and 71.6 ± 2.87, respectively. After 3 weeks of healing, mean BIC% (80.64 ± 13.89%) and RFA value (76.8 ± 1.14) of modSLA implants were significantly higher (P=0.0002) than that of SLA implants (64.39 ± 21.2 BIC% and 74.2 ± 4.76 RFA). However, no statistically significant difference between SLA and modSLA implants was recorded after 6 weeks of healing. Both implants revealed similar results in the RTT test (115.2 ± 4.14 and 117 ± 4.47 N/cm for SLA and modSLA implants, respectively). No correlation was found between RFA and BIC%. Conclusion: Within the limits of this pilot study, it can be concluded that modSLA implants achieve a higher bone contact and stability at earlier time points when compared with SLA implants. To cite this article:
Abdel‐Haq J, Karabuda CZ, Arιsan V, Mutlu Z, Kürkçü M. Osseointegration and stability of a modified sand‐blasted acid‐etched implant: an experimental pilot study in sheep.
Clin. Oral Impl. Res. 22 , 2011; 265–274.
doi: 10.1111/j.1600‐0501.2010.01990.x  相似文献   

2.
Purpose: The aim of this study was to evaluate the success rate of chemically modified and conventional sandblasted acid‐etched surface (SLA) titanium implants in irradiated oral squamous cell carcinoma patients. Material and methods: Twenty patients with a mean age of 61.1 years were treated with dental implants after ablative surgery and radio‐chemotherapy of oral cancer. All patients were non‐smokers. The placement of SLA and modSLA implants was performed bilaterally according to a split‐mouth design. All 102 implants (50 SLA, 52 modSLA) placed showed an unloaded healing time of 6 weeks in the mandible and 10 weeks in the maxilla. Mean crestal bone changes using standardized orthopantomographies and clinical parameters like pocket depths, mPII and mBI were evaluated. Results: Of 102 implants, 55 implants (27 SLA implants, 28 modSLA) were located in the maxilla and 47 implants (23 SLA, 24 modSLA) in the mandible. The average observation period was 14.4 months. The amount of bone loss at the implant shoulder of SLA implants was 0.4 mm mesial and 0.4 mm distal. The modSLA implants displayed a bone loss of mesial 0.3 mm and distal 0.3 mm. Two SLA implants were lost resulting in a success rate of 96%. The success rate of modSLA implants was 100%. Conclusion: Regarding the data found in this investigation, we can conclude that implants with chemically modified and conventional SLA titanium surface show high success rates in irradiated patients. SLA implants with or without a chemically modified surface regardless of the location can be restored with a high predictability of success at least in the short time range observed. To cite this article:
Heberer S, Kilic S, Hossamo J, Raguse J‐D, Nelson K. Rehabilitation of irradiated patients with modified and conventional sandblasted, acid‐etched implants: preliminary results of a split‐mouth study.
Clin. Oral Impl. Res. 22 , 2011; 546–551
doi: 10.1111/j.1600‐0501.2010.02050.x  相似文献   

3.
Objectives: To compare the bone tissue response to surface‐modified zirconia (ZrO2) and titanium implants. Methods: Cylindrical low‐pressure injection moulded zirconia (ZrO2) implants were produced with an acid‐etched surface. Titanium implants with identical shape, sandblasted and acid‐etched surface (SLA) served as controls. Eighteen adult miniature pigs received both implant types in the maxilla 6 months after extraction of the canines and incisors. The animals were euthanized after 4, 8 and 12 weeks and 16 zirconia and 18 titanium implants with the surrounding tissue were retrieved, embedded in methylmethacrylate and stained with Giemsa–Eosin. The stained sections were digitized and histomorphometrically analysed with regard to peri‐implant bone density (bone volume/total volume) and bone–implant contact (BIC) ratio. Statistical analysis was performed using Mann–Whitney' U‐test. Results: Histomorphometrical analysis showed direct osseous integration for both materials. ZrO2 implants revealed mean peri‐implant bone density values of 60.4% (SD ± 9.9) at 4 weeks, 65.4% (SD ± 13.8) at 8 weeks, and 63.3% (SD ± 21.5) at 12 weeks after implantation, whereas Ti‐SLA implants demonstrated mean values of 61.1% (SD ± 6.2), 63.6% (SD ± 6.8) and 68.2% (SD ± 5.8) at corresponding time intervals. Concerning the BIC ratio, the mean values for ZrO2 ranged between 67.1% (SD ± 21.1) and 70% (SD ± 14.5) and for Ti‐SLA between 64.7% (SD ± 9.4) and 83.7% (SD ± 10.3). For the two parameters investigated, no significant differences between both types of implants could be detected at any time point. Conclusion: The results indicate that there was no difference in osseointegration between ZrO2 implants and Ti‐SLA controls regarding peri‐implant bone density and BIC ratio. To cite this article :
Gahlert M, Roehling S, Sprecher CM, Kniha H, Milz S, Bormann K. In vivo performance of zirconia and titanium implants: a histomorphometric study in mini pig maxillae.
Clin. Oral Impl. Res. 23 , 2012; 281–286.
doi: 10.1111/j.1600‐0501.2011.02157.x  相似文献   

4.
Objectives: The aim of the present study was to evaluate bone regeneration in dehiscence‐type defects at non‐submerged and submerged titanium implants with chemically modified (mod) and conventional sandblasted/acid‐etched (SLA) surfaces. Material and Methods: Standardized buccal dehiscence defects were surgically created following implant site preparation in both the upper and lower jaws of 12 beagle dogs. Both types of implants were randomly assigned to either a non‐submerged or a submerged healing procedure. After 1, 2, 4, and 8 weeks, dissected blocks were processed for histomorphometrical [e.g. new bone height (NBH), per cent linear fill (PLF), percentage of bone to implant contact (BIC‐D), area of new bone fill (BF)] and immunohistochemical analysis. Results: At 8 weeks, non‐submerged and submerged SLA implants revealed significantly lower mean NBH (1.1±0.8–1.9±1.2 mm), PLF (27.7±20.3–46.0±28.5%), BIC‐D (26.8±10.4–46.2±16.2%), and BF (1.3±0.9–3.4±2.8 mm2) values than respective modSLA implants [NBH (2.6±0.8–4.3±0.1 mm), PLF (64.2±19.4–107.2±4.7%), BIC‐D (67.5±18.8–82.1±14.8%), BF (2.9±1.0–6.7±1.1 mm2)]. Within modSLA groups, significantly highest BF values were observed at submerged implants. Conclusion: It was concluded that (i) modSLA titanium surfaces promoted bone regeneration in acute‐type buccal dehiscence defects and (ii) a submerged healing procedure improved the outcome of healing additionally.  相似文献   

5.
Objective: To evaluate the predictability of the early‐loaded sand‐blasted, large‐grit and acid‐etched (SLA) implants supporting maxillary‐fixed full‐arch prostheses. Material and methods: Ninety‐one ITI SLA implants were placed in 12 edentulous maxillae. The impressions were taken at 4 weeks post‐surgery. The abutments were tightened and the final fixed prostheses were cemented at 6 weeks after implant placement. Resonance frequency analysis (RFA) was conducted on the day of the surgery, at 4 and 6 weeks post‐surgery. Panoramic radiographs were taken immediately after surgery, at 4 weeks post‐surgery, immediately after prostheses attachment (baseline) and at the yearly follow‐ups. Results: The survival rate of implants was 98.90%. The success rate of prostheses was 100% during the follow‐ups. The radiographic result showed no radiolucency around the implants and the marginal bone level revealed no significant resorption compared with the baseline. The marginal bone level remained coronally beyond the first thread. The RFA results revealed Implant Stability Quotient (ISQ) values of 63.44±4.32, 57.14±4.25 and 66.43±3.78 for the three time points. Conclusions: The findings of this study indicated that early loading of ITI implants supporting maxillary fixed full‐arch prostheses should be predictable.  相似文献   

6.
Objectives: Narrow diameter implants (NDIs; diameter >3.75 mm) are useful in replacement of missing incisor teeth and when the bucco‐lingual width of the edentulous crest is insufficient. The present study evaluated the success and survival rates, peri‐implant parameters, mechanical and prosthetic post‐loading complications of NDIs followed over a 10‐year period. Material and methods: Three hundred and sixteen NDIs were inserted into 139 patients and restored with 120 prostheses. Clinical and radiographic assessment data were collected during recall visits. Implant success (SC), cumulative survival rate (CSR), marginal bone loss (MBL), peri‐implant conditions and prosthetic complications were assessed. Cox proportional hazards regression analysis, Kaplan–Meier survival curves with the log‐rank test and life table analysis were used to evaluate the outcome of NDIs within comparable subgroups. MBL and peri‐implant parameters measured annually were further analyzed. Results: The mean follow‐up time was 9.1 years (range: 60–124 months). Twelve implants were lost in the healing phase and two during function. The mean MBL in the maxilla and the mandible was 1.32 ± 0.13 and 1.28 ± 0.3 mm, respectively, after 10 years. SC and CSR were 91.4% and 92.3%, respectively, after 124 months. Smoking and posterior localization were associated with an increased risk of failure. Cement loosening (16.8%) was the most common prosthetic complication. No implants were fractured. Conclusions: NDIs can be used with confidence where a regular diameter implant is not suitable. MBL around NDIs occurred predominantly within 2 years of loading and was minimal thereafter. Further studies are required to clarify the possible risks associated with smoking and posterior placement. To cite this article:
Arιsan V, Bolukbasι N, Ersanlι S, Ozdemir T. Evaluation of 316 narrow diameter implants followed for 5–10 years: a clinical and radiographic retrospective study.
Clin. Oral Impl. Res. 21 , 2010; 296–307.
doi: 10.1111/j.1600‐0501.2009.01840.x  相似文献   

7.
Objective: To evaluate the effect of the timing of loading on bone‐to‐implant contact (BIC) following immediate placement of implants with a hydrophilic sandblasted, large‐grit and acid‐etched surface (modSLA) into fresh extraction sockets in a minipig model. Material and methods: Six minipigs were used in this study. In each hemi‐mandible, two conical shape implants (TE, Straumann implants) with a hydrophilic surface (modSLA) were placed in fresh extraction sockets. In one side of the mandible (control), two implants were immediately placed in fresh extraction sockets. The implants were loaded after 4 weeks of healing. At the contralateral side (test), two implants were immediately placed and loaded. After 8 weeks of healing, the animals were sacrificed and histologically analysed. Results: During the experimental period, no implants were lost and all of them presented to be osseointegrated. The percentage of BIC was similar in both groups: 66.1% and 65.1% for the control and test group, respectively. Furthermore, the distance from the shoulder of the implant to bone crest and the distance from the shoulder to the first BIC were similar in both groups. Conclusion: Immediate implant placement and loading showed similar BIC with immediate placement and delayed loading when implants with a modSLA surface were used. Both procedures showed similar buccal bone crest levels, which presented some resorption irrespective of the treatment modality. To cite this article:
Liñares A, Mardas N, Dard M, Donos N. Effect of immediate or delayed loading following immediate placement of implants with a modified surface.
Clin. Oral Impl. Res. 22 , 2011; 38–46.
doi: 10.1111/j.1600‐0501.2010.01988.x  相似文献   

8.
Purpose: The aim of this study was to show prognostic equivalence between implant loading in the maxilla after 12 weeks versus 4 weeks. Materials and Methods: One hundred four patients, from four centers in this open‐labeled randomized multicenter prospective controlled clinical trial, were assigned to either 12 weeks or 4 weeks of unloaded healing. Two hundred sixty‐nine implants (sand blasted large‐grid, acid etched [SLA] surface, ≥4.1 mm diameter; ≥10 mm length) were inserted and evaluated during an individual 5‐year follow‐up. Primary outcome was implant success after 12 months; prognostic equivalence was characterized by a maximum difference of ±5% in implant failure rates. Results: Implant‐wise 1‐year failure rates were estimated 3.1% (5/163 implants) in the 4 weeks group versus 3.6% (4/112 implants) in the 12 weeks group (95% confidence interval [CI] for the difference ?3.2 –+4.2%); implant‐wise evaluation demonstrated statistically significant prognostic equivalence of 4 and 12 weeks loading. Patient‐wise 1‐year failure rates were estimated 6.7% (n = 4 patients) in the 4 weeks group versus 5.1% (n = 2 patients) in the 12 weeks group (95% CI for the difference ?9.6 –+6.5%). All implant failures occurred within the first 3 months of the individual observation period. Prior bone augmentation, underdimensioned drilling, bone quality, implant type, implant length, implant diameter, residual teeth, and fixing of the restoration did not reveal associations with the implant outcome: trial site, posterior jaw region, and splinting were associated with a higher failure rate. Resonance frequency analysis did not serve as a predictor of implant failures at the time of implant insertion. Conclusion: Loading of standard SLA implants in the maxilla 4 weeks versus 12 weeks after insertion resulted in statistically equivalent failure patterns within a 1‐year follow‐up period; nevertheless, the observed patient‐wise failure patterns of the interim analysis requires further understanding of patient‐individual aspects of the early loading concept.  相似文献   

9.
Objectives: To assess the influence of two barrier membranes and two bone graft substitutes on staged guided bone regeneration and osseointegration of titanium implants in dogs. Materials and methods: Saddle‐type defects were prepared in the lower jaws of 6 fox hounds and randomly filled with a natural bone mineral (NBM) and a biphasic calcium phosphate (SBC) and allocated to either an in situ gelling polyethylene glycol (PEG) or a collagen membrane (CM). At 8 weeks, modSLA titanium implants were inserted and left to heal in a submerged position. At 8+2 weeks, respectively, dissected blocks were processed for histomorphometrical analysis (e.g., mineralized tissue [MT], bone‐to‐implant contact [BIC]). Results: The mean MT values (mm2) and BIC values (%) tended to be higher in the PEG groups (MT: NBM [3.4±1.7]; SBC [4.2±2]/BIC: NBM [67.7±16.9]; SBC [66.9±17.8]) when compared with the corresponding CM groups (MT: NBM [2.5±0.8]; SBC [2.3±1.6]/BIC: NBM [54.1±22.6]; SBC [61±8.7]). These differences, however, did not reach statistical significance. Conclusion: It was concluded that all augmentation procedures investigated supported bone regeneration and staged osseointegration of modSLA titanium implants. To cite this article :
Mihatovic I, Becker J, Golubovic V, Hegewald A, Schwarz F. Influence of two barrier membranes on staged guided bone regeneration and osseointegration of titanium implants in dogs. Part 2: augmentation using bone graft substitutes.
Clin Oral Impl Res. 23 , 2012; 308–315.
doi: 10.1111/j.1600‐0501.2011.02238.x  相似文献   

10.
Objectives: The early stages of peri‐implant bone formation play an essential role in the osseointegration and long‐term success of dental implants. By incorporating bioactive coatings, this biofunctionalization of implant surfaces may enhance the attachment of the implant to the surrounding bone and stimulate bone regeneration. Material and methods: To demonstrate faster osseointegration, the surfaces of dental implants were grit‐blasted and acid‐etched. They were then coated with hydroxyapatite (HA) and experimental implants were further coated with a biomimetic active peptide (P‐15) in one of two concentrations. These biofunctionalized samples and controls with no peptide were placed in the forehead region of 12 adult pigs. Six animals were evaluated for a period of 14 or 30 days. Results: Histomorphometric analysis demonstrated that the implants with the high concentration of P‐15 had significantly higher percentage of bone‐to‐implant contact (BIC) at 14 (P=0.018) and 30 (P=0.015) days compared with the other groups. Both concentrations of P‐15 showed increased peri‐implant bone density compared to the control group at 30 days. Conclusion: Biofunctionalization of the implant surface with a biomimetic active peptide leads to significantly increased BIC rates at 14 and 30 days and higher peri‐implant bone density at 30 days. To cite this article:
Lutz R, Srour S, Nonhoff J, Weisel T, Damien CJ, Schlegel KA. Biofunctionalization of titanium implants with a biomimetic active peptide (P‐15) promotes early osseointegration.
Clin. Oral Impl. Res. 21 , 2010; 726–734.
doi: 10.1111/j.1600‐0501.2009.01904.x  相似文献   

11.
Objectives: To assess the influence of two barrier membranes and two bone graft substitutes mixed with autogenous bone (AB) on staged guided bone regeneration and osseointegration of titanium implants in dogs. Materials and methods: Four saddle‐type defects each were prepared in the upper jaw of six fox hounds and randomly filled with a natural bone mineral (NBM)+AB and a biphasic calcium phosphate (SBC)+AB and allocated to either an in situ gelling polyethylene glycol (PEG) or a collagen membrane (CM). At 8 weeks, modSLA titanium implants were inserted and left to heal in a submerged position. At 8+2 weeks, dissected blocks were processed for histomorphometrical analysis (e.g., treated area [TA], bone‐to‐implant contact [BIC]). Results: The mean TA values (mm2) and BIC values (%) tended to be higher in the PEG groups(TA: NBM+AB [10.4 ± 2.5]; SBC+AB [10.4 ± 5.8]/BIC: NBM+AB [86.4 ± 20.1]; SBC+AB [80.1 ± 21.5]) when compared with the corresponding CM groups (TA: NBM+AB [9.7 ± 4.8]; SBC+AB [7.8 ± 4.3]/BIC: NBM+AB [71.3 ± 20.8]; SBC+AB [72.4 ± 20.3]). A significant difference was observed for the mean TA values in the SBC+AB groups. Conclusion: It was concluded that all augmentation procedures investigated supported bone regeneration and staged osseointegration of modSLA titanium implants. However, the application of PEG may be associated with increased TA values. To cite this article:
Schwarz F, Mihatovic I, Golubovic V, Hegewald A, Becker J. Influence of two barrier membranes on staged guided bone regeneration and osseointegration of titanium implants in dogs: part 1. Augmentation using bone graft substitutes and autogenous bone.
Clin. Oral Impl. Res. 23 , 2012; 83–89.
doi: 10.1111/j.1600‐0501.2011.02187.x  相似文献   

12.

Objectives

The objective of this 3‐year split‐mouth randomized controlled clinical study was to compare narrow‐diameter implants (NDIs) to regular‐diameter implants (RDIs) in the posterior region of the jaws (premolars and molars) in regards to (i) the marginal bone level (MBL) and (ii) implant and prosthesis survival and success rates.

Material and Methods

A total of 22 patients were included in the study. Each patient received at least one implant of each diameter (Ø3.3 and Ø4.1 mm), placed either in the maxilla or mandible to support single crowns. A total 44 implants (22 NDIs and 22 RDIs) were placed and included in the study. Twenty‐one implants were placed in the premolar, whereas 23 were placed in molar areas. Radiographic evaluations to access the MBL were performed immediately after implant placement, 1 and 3 years after implant loading. Peri‐implant clinical variables including probing pocket depth (PPD) and bleeding on probing (BoP) were obtained after crown delivery, 1 and 3 years after loading. Furthermore, the survival and success rates of the implants and prosthesis were also evaluated.

Results

Twenty patients were able to complete the study. There was no statistically significant difference regarding MBL between groups at implant placement (p = .084), 1‐year (p = .794) and 3‐year (p = .598) time intervals. The mean peri‐implant bone loss at 3‐year follow‐up was ?0.58 ± 0.39 mm (95% CI: ?0.751 to ?0.409) and ?0.53 ± 0.46 mm (95% CI: ?0.731 to ?0.329) for NDIs and RDIs, respectively. BoP was present at 15% and 10% of NDIs and RDIs, respectively, at 3‐year follow‐up. PPD >5 mm was observed in 5% and 0% of the implants of NDIs and RDIs, respectively, at 3‐year follow‐up. At the 3‐year examination, the implant success rates were in the NDIs and RDIs sites, respectively, 95% and 100%. The corresponding values for prosthesis success rates were 90% for NDIs and 95% for RDIs.

Conclusion

The present study demonstrated that NDIs placed to support single crowns in the posterior region did not differ to RDIs in regards to MBL, implant survival, and success rates.  相似文献   

13.
Aim: To evaluate prospectively the clinical and radiographic outcomes after 2 years of loading of 6 mm long moderately rough implants supporting single crowns in the posterior regions. Material and methods: Forty SLActive Straumann® short (6 mm) implants were placed in 35 consecutively treated patients. Nineteen implants, 4.1 mm in diameter, and 21 implants, 4.8 mm in diameter, were installed. Implants were loaded after 6 weeks of healing. Implant survival rate, marginal bone loss and resonance frequency analysis (RFA) were evaluated at different intervals. The clinical crown/implant ratio was also calculated. Results: Two out of 40 implants were lost before loading. Hence, the survival rate before loading was 95%. No further technical or biological complications were encountered during the 2‐year follow‐up. The mean marginal bone loss before loading was 0.34±0.38 mm. After loading, the mean marginal bone loss was 0.23±0.33 and 0.21±0.39 mm at the 1‐ and 2‐year follow‐ups. The RFA values increased between insertion (70.2±9) and the 6‐week evaluation (74.8±6.1). The clinical crown/implant ratio increased with time from 1.5 at the delivery of the prosthesis to 1.8 after 2 years of loading. Conclusion: Short implants (6 mm) with a moderately rough surface loaded early (after 6 weeks) during healing yielded high implant survival rates and moderate loss of bone after 2 years of loading. Longer observation periods are needed to draw more definite conclusions on the reliability of short implants supporting single crowns. To cite this article:
Rossi F, Ricci E, Marchetti C, Lang NP, Botticelli D. Early loading of single crowns supported by 6‐mm‐long implants with a moderately rough surface: a prospective 2‐year follow‐up cohort study.
Clin. Oral Impl. Res. 21 , 2010; 937–943.
doi: 10.1111/j.1600‐0501.2010.01942.x  相似文献   

14.
Background: Positive effects on the clinical outcome of moderately rough implant surfaces are described. Intercomparison of clinical data, however, is rarely found. Purpose: The aim of this study was to compare the clinical results of two macroscopically identical implants, the one with a turned, machined and the other with an etched surface. Materials and Methods: In a retrospective cohort study, the included implants followed the criteria: standard surgical protocol, >12 months in situ; minimally rough self‐threading implants with a turned, machined surface (Mk IITM Nobel Biocare AB, Göteborg, Sweden], n=210); etched implants of the same macrodesign (3iTM Implant Innovations Inc., Palm Beach Gardens, FL, USA], n=151), length ≥ 10 mm. Clinical data and implant success were rated. Resonance frequency analysis (RFA) and Periotest® (Siemens AG, Bensheim, Germany) were measured and related to the corresponding implant survival rate in the respective group. Results: The total number of implants was 361, of which 264 (73%) were subject to clinical reexamination. RFA and Periotest could be recorded in 25% of the implants. Neither clinically relevant nor statistically significant differences between the surface designs were found in the RFA (64 ± 8.6 vs 63 ± 9.7), in Periotest (?2 ± 3.3 vs ?1 ± 5.1), and in mean survival periods (49 months, 95% confidence interval CI]: 46–51 months, for the turned vs 46 months, 95% CI: 43–49 months, for the double‐etched implant). After osteoplastic procedures, a significantly higher rate of implant losses in the turned, machined implant group was observed (17 vs 1) with a mean survival period of 43 (40–46) months for the turned and 46 (45–48) months for the double‐etched implants. Conclusion: No difference between implants with two different minimally rough surfaces was found. A positive effect of surface roughness is observed in poor quality bone, but the pivotal proof of this effect is still lacking.  相似文献   

15.
Objectives: This prospective multicentre study provides clinical experience up to 3 years to support a simplified treatment for mandibular edentulism within 1 week by using one‐stage implant surgery and a screw‐retained full‐arch bridge. Methods: Two hundred and fifty ITI Monotype® implants were installed in 62 patients out of 66 patients; 60 patients got four implants each and two got five implants. After 1 week, a final bridge was in function. Radiographs were taken as baseline for vertical bone loss up to 3 years post‐loading for the whole cluster and specific effects of gender, centre, age, bone class, implant length over time were compiled. Clinical (mPI, SBI) and subjective parameters such as general oral hygiene and patient satisfaction were recorded and repeated at specified intervals up to 3 years. Results: Four patients were excluded at surgery and are not involved in the follow‐ups. At 1 year, 61 patients (244 implants) were evaluable and all bridges were in function. After 3 years, 49 patients (194 implants) came to control. Eight patients died during the follow‐up period. Three patients lost one implant each. The cumulative implant survival rate was 98.55% and the success rate for the prosthesis was 100%. As calculated from measurable radiographs, the mean bone level at baseline was 1.63±0.78 and at 1 and 3 years 2.50±0.60 and 2.56±0.74, respectively. Using the mixed model analysis and Friedman test, the time in situ, centre and bone class had significant effect on the bone resorption and to some small extent even, the implant length. Gender and age were unaffected. Oral hygiene and patient satisfaction of the treatment were improved. Conclusions: The results indicate that one‐part self‐tapping sandblasted, large‐grit, acid‐etched (SLA) implants are suitable for loading within 1 week. In the whole period, the mean bone crestal resorption was <1 mm, which is in agreement with other similar studies.  相似文献   

16.
Objectives: The aim of this study was to analyse the influence of the microtopography and hydrophilicity of titanium (Ti) substrates on initial oral biofilm formation. Materials and methods: Nine bacterial species belonging to the normal oral microbiota, including: Aggregatibacter actinomycetemcomitans, Actinomyces israelii, Campylobacter rectus, Eikenella corrodens, Fusobacterium nucleatum, Parvimonas micra, Porphyromonas gingivalis, Prevotella intermedia, and Streptococcus sanguinis were tested on Ti surfaces: pretreatment (PT [Ra<0.2 μm]), acid‐etched (A [Ra<0.8 μm]), A modified to be hydrophilic (modA), sand‐blasted/acid‐etched (SLA [Ra=4 μm]), and hydrophilic SLA (modSLA). Disks were incubated for 24 h in anaerobic conditions using a normal culture medium (CM) or human saliva (HS). The total counts of bacteria and the proportion of each bacterial species were analysed by checkerboard DNA–DNA hybridization. Results: Higher counts of bacteria were observed on all surfaces incubated with CM compared with the samples incubated with HS. PT, SLA, and modSLA exhibited higher numbers of attached bacteria in CM, whereas SLA and modSLA had a significant increase in bacterial adhesion in HS. The proportion of the species in the initial biofilms was also influenced by the surface properties and the media used: SLA and modSLA increased the proportion of species like A. actinomycetemcomitans and S. sanguinis in both media, while the adhesion of A. israelii and P. gingivalis on the same surfaces was affected in the presence of saliva. Conclusions: The initial biofilm formation and composition were affected by the microtopography and hydrophilicity of the surface and by the media used. To cite this article:
Almaguer‐Flores A, Olivares Navarrete R, Wieland M, Ximénez‐Fyvie LA, Schwartz Z, Boyan BD. Influence of topography and hydrophilicity on initial oral biofilm formation on microstructured titanium surfaces in vitro.
Clin. Oral Impl. Res. 23 , 2012; 301–307.
doi: 10.1111/j.1600‐0501.2011.02184.x  相似文献   

17.
Aim: To monitor longitudinally the development of implant stability of SLA Straumann® tissue‐level implants using resonance frequency analysis (RFA) and to determine the influence of instrument positioning, bone structure and implant length on the assessment of RFA. Material and methods: Thirty‐two healthy adult patients received either 8 mm, ?4.1 mm Straumann® Standard Plus tissue‐level implants (n=16: Group A) or 10 mm, ?4.1 mm Straumann® Standard Plus tissue‐level implants (n=16: Group B). During healing, RFA was performed on Weeks 0,1, 2, 3, 4, 5, 6, 8 and 12. The implants were restored after 10 weeks (impression taking) and 12 weeks. In addition, probing depth, presence of plaque and bleeding on probing were assessed. Implant stability quotient (ISQ) values of Groups A and B were compared using unpaired t‐tests and longitudinally applying paired t‐tests between Week 0 and the subsequent time points. Results: Positioning of the Osstell?mentor device did not affect the ISQ values. Generally, ISQ values increased continuously during healing from a mean of 65.1 (SD 16.97) to 74.7 (SD 5.17) (significantly from Week 0 to Weeks 6, 8 and 12). Lower bone density (Type III or IV) resulted in significantly lower ISQ values up to Week 8. Implant length affected the increase in ISQ values over time. While no significant increase was observed with 10 mm implants, ISQ values of 8 mm implants increased significantly from Week 0 to Weeks 6, 8 and 12. Conclusions: Using Osstell?mentor, ISQ values are reproducible irrespective of instrument positioning. ISQ values are affected by the bone structure and implant length. Hence, no predictive values can be attributed to implant stability. To cite this article:
Sim CPC, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell?mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length.
Clin. Oral Impl. Res. 21 , 2010; 598–604.
doi: 10.1111/j.1600‐0501.2009.01878.x  相似文献   

18.
Objectives: To evaluate the effect of maximum bite force (mBF) on marginal bone loss (MBL) around mini‐implants in edentulous patients wearing mandibular overdentures with two retention systems: ball and bar. Material and methods: Forty‐five totally edentulous patients were selected from a public health center. All of them received two mini‐implants (1.8 × 15 mm; Sendax®) in the anterior mandible using a minimally invasive technique. A single randomization was performed to allocate the patients in two groups. Group I (n=22) received two single ball‐type mini‐implants and Group II (n=23) received two mini‐implants splinted with a prefabricated bar. The mBF was recorded using a press‐sensitive sheet Dental Prescale® (Fuji) and MBL using standardized radiographs of each mini‐implant at the baseline and 5, 7, 10, and 15 months after surgery; the values were compared between groups. Results: Two members of Group I failed to complete the study, decreasing the number of participants to 20. There was no relationship between the mBF and the MBL of the mini‐implants (Spearman's ρrs=0.147; P=0.378). At the 15‐month follow‐up, the average mBF for Group I (ball) was 247.53 ± 132.91 N and that of Group II (bar) only 203.23 ± 76.85 N (Mann–Whitney test; P=0.586). The MBL values were also higher for Group I (1.40 ± 1.02 mm) than Group II (0.84 ± 0.66 mm) during the entire 15‐month follow‐up period (Mann–Whitney test; P=0.077). Conclusions: No relationship was found between mBF and MBL for patients wearing overdentures retained on mini‐implants using bar or ball attachment systems. To cite this article:
Jofré J, Hamada T, Nishimura M, Klattenhoff C. The effect of maximum bite force on marginal bone loss of mini‐implants supporting a mandibular overdenture: a randomized controlled trial.
Clin. Oral Impl. Res. 21 , 2010; 243–249.
doi: 10.1111/j.1600‐0501.2009.01834.x  相似文献   

19.
Objectives: To monitor the development of the stability of Straumann® tissue‐level implants during the early phases of healing by resonance frequency analysis (RFA) and to determine the influence of implant surface modification and diameter. Material and methods: A total of twenty‐five 10 mm length implants including 12 SLA RN ?4.1 mm implants, eight SLActive RN ?4.1 mm implants and five SLA WN ?4.8 mm implants were placed. Implant stability quotient (ISQ) values were determined with Osstell?mentor at baseline, 4 days, 1, 2, 3, 4, 6, 8 and 12 weeks post‐surgery. ISQ values were compared between implant types using unpaired t‐tests and longitudinally within implant types using paired t‐tests. Results: During healing, ISQ decreased by 3–4 values after installation and reached the lowest values at 3 weeks. Following this, the ISQ values increased steadily for all implants and up to 12 weeks. No significant differences were noted over time. The longitudinal changes in the ISQ values showed the same patterns for SLA implants, SLActive implants and WB implants. At placement, the mean ISQ values were 72.6, 75.7 and 74.4, respectively. The mean lowest ISQ values, recorded at 3 weeks, were 69.9, 71.4 and 69.8, respectively. At 12 weeks, the mean ISQ values were 76.5, 78.8 and 77.8, respectively. The mean ISQ values at all observation periods did not differ significantly among the various types. Single ISQ values ranged from 55 to 84 during the entire healing period. Pocket probing depths of the implants ranged from 1 to 3 mm and bleeding on probing from 0 to 2 sites/implant post‐surgically. Conclusions: All ISQ values indicated the stability of Straumann® implants over a 12‐week healing period. All implants showed a slight decrease after installation, with the lowest ISQ values being reached at 3 weeks. ISQ values were restored 8 weeks post‐surgically. It is recommended to monitor implant stability by RFA at 3 and 8 weeks post‐surgically. However, neither implant surface modifications (SLActive) nor implant diameter were revealed by RFA. To cite this article:
Han J, Lulic M, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell?mentor during implant tissue integration: II. Implant surface modifications and implant diameter.
Clin. Oral Impl. Res. 21 , 2010; 605–611.
doi: 10.1111/j.1600‐0501.2009.01909.x  相似文献   

20.
Objectives: The aim of the study was to evaluate new bone formation under etched titanium (SLA) and modified‐etched hydrophilic titanium (modSLA) domes placed on the calvarium of healthy, osteoporotic and osteoporotic treated with bisphosphonates rabbits. Methods: Experimental osteoporosis was induced by ovariectomy (OV) and calcium‐deficient diet in 24 New Zealand female rabbits. Twelve OV rabbits were treated with weekly dozes of alendronate (Fosamax®) (B) while 12 OV rabbits received no treatment (O). Another 12 rabbits were sham operated and used as healthy controls (C). At 6 weeks following OV, one modSLA and one SLA titanium dome were placed in the parietal bones of each rabbit. The animals were sacrificed at 30 and 120 days following the dome placement. Various histomorphometric measurements were performed in the most central of the undecalcified sections produced. Results: After 30 days of healing, in the C group, the total bone (TB) area was 37.6% and 37.0% under the modSLA and SLA domes, respectively. In the O group, the TB was 35.7% and 24.8%. In the B group, TB was 37.0% and 32.1%, respectively. After 120 days of healing, in the C group TB was 40.1% and 36.4%, respectively. In the O group, TB was 29.6% and 27.9%, respectively. In the B group, TB was 49.7% and 42.5%, respectively. Hierarchical analysis of variance showed that the type of titanium dome significantly influenced new bone and the amount of new bone being in contact with inner surface of the dome (BIC) independently of the observation period and group (P<0.05). The administration of bisphosphonates influenced the BIC (P<0.05). Conclusion: The use of modSLA surface may promote bone healing and osseointegration in osteoporotic rabbits, whereas administration of bisphosphonates may compromise the osseointegration of the newly formed bone at the early healing period. To cite this article:
Mardas N, Schwarz F, Petrie A, Hakimi A‐R, Donos N. The effect of SLActive surface in guided bone formation in osteoporotic‐like conditions.
Clin. Oral Impl. Res. 22 , 2011; 406–415.
doi: 10.1111/j.1600‐0501.2010.02094.x  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号