首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到5条相似文献,搜索用时 0 毫秒
1.
2.

Purpose

To identify and compare predictors of local tumor progression (LTP)-free survival (LTPFS) after radiofrequency (RF) ablation and microwave (MW) ablation of colorectal liver metastases (CLMs).

Materials and Methods

This is a retrospective review of CLMs ablated from November 2009 to April 2015 (110 patients). Margins were measured on contrast-enhanced computed tomography (CT) 6 weeks after ablation. Clinical and technical predictors of LTPFS were assessed using a competing risk model adjusted for clustering.

Results

Technique effectiveness (complete ablation) was 93% (79/85) for RF ablation and 97% (58/60) for MW ablation (P = .47). The median follow-up period was significantly longer for RF ablation than for MW ablation (56 months vs. 29 months) (P < .001). There was no difference in the local tumor progression (LTP) rates between RF ablation and MW ablation (P = 0.84). Significant predictors of shorter LTPFS for RF ablation on univariate analysis were ablation margins 5 mm or smaller (P < .001) (hazard ratio [HR]: 14.6; 95% confidence interval [CI]: 5.2–40.9) and perivascular tumors (P = .021) (HR: 2.2; 95% CI: 1.1–4.3); both retained significance on multivariate analysis. Significant predictors of shorter LTPFS on univariate analysis for MW ablation were ablation margins 5 mm or smaller (P < .001) (subhazard ratio: 11.6; 95% CI: 3.1–42.7) and no history of prior liver resection (P < .013) (HR: 3.2; 95%: 1.3–7.8); both retained significance on multivariate analysis. There was no LTP for tumors ablated with margins over 10 mm (median LTPFS: not reached). Perivascular tumors were not predictive for MW ablation (P = .43).

Conclusions

Regardless of the thermal ablation modality used, margins larger than 5 mm are critical for local tumor control, with no LTP noted for margins over 10 mm. Unlike RF ablation, the efficiency of MW ablation was not affected for perivascular tumors.  相似文献   

3.

Objective

To determine in vivo efficacy of radiofrequency ablation (RFA) in porcine liver by using 15-gauge Octopus® (15-G Octopus®) electrodes to create a large coagulation.

Materials and Methods

A total of 18 coagulations were created by using a 180-W generator and 15-G Octopus® electrodes during laparotomy, performed in 14 pigs. Coagulation necrosis was created in the pig livers by the use of one of three RFA protocols: 1) group A, monopolar RFA using a 15-G Octopus® electrode with a 5-mm inter-electrode distance (n = 4); 2) group B, monopolar RFA using a 15-G Octopus® electrode with a 10-mm inter-electrode distance (n = 6); and 3) group C, switching monopolar RFA using two 15-G Octopus® electrodes (n = 8). The energy efficiency, shape, maximum and minimum diameters (Dmx and Dmi), and the volume of the coagulation volume were measured in each group. The Summary statistics were obtained and Mann-Whitney test was were performed.

Results

The mean ablated volume of each group was 49.23 cm3 in A, 64.11 cm3 in B, and 72.35 cm3 in C. The mean Dmx and Dmi values were 5.68 cm and 4.58 cm in A and 5.97 cm and 4.97 cm in B, respectively. In group C, the mean diameters of Dmx and Dmi were 6.80 cm and 5.11 cm, respectively. The mean ratios of Dmi/Dmx were 1.25, 1.20, and 1.35 in groups A, B, and C, respectively. There was one animal death during the RFA procedure, the cause of which could not be subsequently determined. However, there were no other significant, procedure-related complications during the seven-hour-delayed CT scans.

Conclusion

RFA procedures using 15-G Octopus® electrodes are useful and safe for creating a large ablation in a single electrode model as well as in the multiple electrodes model.  相似文献   

4.
BACKGROUND AND PURPOSE: Colloid cysts of the third ventricle are rare benign brain tumors. The purpose of this study was to correlate their patterns on MR images with the probability of success of percutaneous treatment. METHODS: Nineteen patients underwent endoscopic treatment for colloid cysts of the third ventricle. The cases were divided into two groups based on difficulty of the aspiration procedure. We reviewed CT scans and MR images and divided cysts into groups based on their signal intensity on the MR images and their density on CT scans. Intensity and density were correlated with difficulty of aspiration during the endoscopic procedure. RESULTS: The aspiration procedure was difficult in 63% of the cases. Eighty-nine percent of hyperdense cysts on unenhanced axial CT scans were categorized as difficult, and 75% of hypodense cysts were categorized as easy. On T2-weighted MR sequences, 100% of low-signal cyst contents were difficult and nearly 63% of high-signal lesions were easy. There was a significant correlation between the T2-weighted sequences and the CT scans regarding the difficulty of the aspiration procedure. CONCLUSION: T2-weighted MR sequences are useful for predicting difficulty of aspiration during stereotactic or endoscopic procedures. A T2-weighted low-signal cyst is correlated with high-viscosity intracystic contents.  相似文献   

5.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号