共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Liang Zhang Na Wang Jingsong Mao Xiaofei Liu Zhichun Gao Xu Dai Bo Feng 《Journal of vascular and interventional radiology : JVIR》2018,29(10):1455-1461
Purpose
To evaluate whether changes in volumetric iodine concentration (VIC) could serve as a suitable predictor of therapeutic response to microwave (MW) ablation in a rabbit intrahepatic VX2 tumor model.Materials and Methods
Sixteen intrahepatic VX2 tumors were transplanted in 8 New Zealand White rabbits treated with MW ablation. Contrast-enhanced dual-energy CT scans were obtained at baseline and follow-up. Therapeutic response assessment by modified Response Evaluation Criteria In Solid Tumors (mRECIST), Choi criteria, and VIC changes was performed. An intraclass correlation coefficient (ICC) was used to characterize consistency of assessment results among the criteria used. Technical success was evaluated with explant pathologic findings as a reference. Correlations between technical success and variations in diameter, CT density, and VIC were analyzed.Results
Disease control was observed in 4, 8, and 10 of the 16 tumors per mRECIST, Choi criteria, and VIC changes, respectively. VIC exhibited strong consistency (ICC = 0.807, P < .0001) with Choi criteria. According to explant pathology, technical success was achieved in 10 of the 16 tumors. There was a moderate correlation between VIC changes and technical success (r = 0.532, P = .034), and no correlation was found between technical success and variations in diameter or CT density.Conclusions
Compared with mRECIST and Choi criteria, dual-energy CT–derived VIC allowed for better prediction of therapeutic response after MW ablation and could provide a potential imaging biomarker of tumor response to MW ablation in patients with hepatocellular carcinoma. 相似文献3.
4.
5.
《Journal of vascular and interventional radiology : JVIR》2023,34(3):395-403.e5
PurposeTo establish molecular magnetic resonance (MR) imaging instruments for in vivo characterization of the immune response to hepatic radiofrequency (RF) ablation using cell-specific immunoprobes.Materials and MethodsSeventy-two C57BL/6 wild-type mice underwent standardized hepatic RF ablation (70 °C for 5 minutes) to generate a coagulation area measuring 6–7 mm in diameter. CD68+ macrophage periablational infiltration was characterized with immunohistochemistry 24 hours, 72 hours, 7 days, and 14 days after ablation (n = 24). Twenty-one mice were subjected to a dose-escalation study with either 10, 15, 30, or 60 mg/kg of rhodamine-labeled superparamagnetic iron oxide nanoparticles (SPIONs) or 2.4, 1.2, or 0.6 mg/kg of gadolinium-160 (160Gd)-labeled CD68 antibody for assessment of the optimal in vivo dose of contrast agent. MR imaging experiments included 9 mice, each receiving 10-mg/kg SPIONs to visualize phagocytes using T21-weighted imaging in a horizontal-bore 9.4-T MR imaging scanner, 160Gd-CD68 for T1-weighted MR imaging of macrophages, or 0.1-mmol/kg intravenous gadoterate (control group). Radiological-pathological correlation included Prussian blue staining, rhodamine immunofluorescence, imaging mass cytometry, and immunohistochemistry.ResultsRF ablation–induced periablational infiltration (206.92 μm ± 12.2) of CD68+ macrophages peaked at 7 days after ablation (P < .01) compared with the untreated lobe. T21-weighted MR imaging with SPION contrast demonstrated curvilinear T21 signal in the transitional zone (TZ) (186 μm ± 16.9), corresponsing to Iron Prussian blue staining. T1-weighted MR imaging with 160Gd-CD68 antibody showed curvilinear signal in the TZ (164 μm ± 3.6) corresponding to imaging mass cytometry.ConclusionsBoth SPION-enhanced T21-weighted and 160Gd-enhanced T1-weighted MR imaging allow for in vivo monitoring of macrophages after RF ablation, demonstrating the feasibility of this model to investigate local immune responses. 相似文献
6.
7.
8.
Eun Sun Lee Jeong Min Lee Kyung Won Kim In Joon Lee Joon Koo Han Byung Ihn Choi 《Korean journal of radiology》2013,14(2):194-201
Objective
To determine in vivo efficacy of radiofrequency ablation (RFA) in porcine liver by using 15-gauge Octopus® (15-G Octopus®) electrodes to create a large coagulation.Materials and Methods
A total of 18 coagulations were created by using a 180-W generator and 15-G Octopus® electrodes during laparotomy, performed in 14 pigs. Coagulation necrosis was created in the pig livers by the use of one of three RFA protocols: 1) group A, monopolar RFA using a 15-G Octopus® electrode with a 5-mm inter-electrode distance (n = 4); 2) group B, monopolar RFA using a 15-G Octopus® electrode with a 10-mm inter-electrode distance (n = 6); and 3) group C, switching monopolar RFA using two 15-G Octopus® electrodes (n = 8). The energy efficiency, shape, maximum and minimum diameters (Dmx and Dmi), and the volume of the coagulation volume were measured in each group. The Summary statistics were obtained and Mann-Whitney test was were performed.Results
The mean ablated volume of each group was 49.23 cm3 in A, 64.11 cm3 in B, and 72.35 cm3 in C. The mean Dmx and Dmi values were 5.68 cm and 4.58 cm in A and 5.97 cm and 4.97 cm in B, respectively. In group C, the mean diameters of Dmx and Dmi were 6.80 cm and 5.11 cm, respectively. The mean ratios of Dmi/Dmx were 1.25, 1.20, and 1.35 in groups A, B, and C, respectively. There was one animal death during the RFA procedure, the cause of which could not be subsequently determined. However, there were no other significant, procedure-related complications during the seven-hour-delayed CT scans.Conclusion
RFA procedures using 15-G Octopus® electrodes are useful and safe for creating a large ablation in a single electrode model as well as in the multiple electrodes model. 相似文献9.
10.
11.
Assessment of breast cancer response to neoadjuvant chemotherapy: is volumetric MRI a reliable tool?
Lorenzon M Zuiani C Londero V Linda A Furlan A Bazzocchi M 《European journal of radiology》2009,71(1):82-88
The purpose of this study was to evaluate the reliability of volumetric magnetic resonance imaging (MRI) in breast cancer size assessment before, during and after neoadjuvant chemotherapy (NAC).Volumetric MRI measures performed on 15 patients with breast cancer were compared with volumes reckoned upon mean lesional diameters, using the same MRI data. Concordance correlation coefficient (CCC), Bland & Altman plots, RECIST evaluation and Cohen's Kappa were assessed, to evaluate the agreement between the two methods.CCC was computed before (0.9357), during (0.8053) and after (0.7499) NAC, in all examinations pooled together (0.8617), and on final tumor volume as a percentage of baseline volume (0.9224). In 2/15 (13.3%) cases RECIST assessment was different. Cohen's Kappa was 0.787 (CI95% = 0.513-1.062).In summary, volumetric MRI is a reliable tool to assess breast cancer size before, during and after NAC. Further investigations are needed to understand whether improvements in surgical planning are feasible. 相似文献
12.
Derek W. Cool John R. Kachura 《Journal of vascular and interventional radiology : JVIR》2017,28(12):1658-1663
Purpose
To evaluate oncologic outcomes and graft viability after percutaneous radiofrequency (RF) ablation of renal cell carcinoma (RCC) developing within renal transplant allografts.Materials and Methods
A single-institution, retrospective study reviewed all patients treated with RF ablation for RCC between February 2004 and May 2016. Ten patients were identified (age 49.6 y ± 12.6; 9 men, 1 woman) with 12 biopsy-confirmed RCC tumors within the allograft (all T1a, mean diameter 2.0 cm ± 0.7). Mean time from transplant to RCC diagnosis was 13.2 years ± 6.3. RF ablation was performed on an outpatient basis using conscious sedation. Procedural efficacy, complications, oncologic outcomes, and allograft function were evaluated. Statistical analysis with t tests and Pearson correlation compared allograft function before and after RF ablation and impact of proportional ablation size to allograft volume on function after ablation.Results
Technical success rate and primary technique efficacy were 100% (12/12). No local or distant RCC progression was seen at mean follow-up of 54.3 months ± 38.7 (range, 9–136 months). Graft failure requiring hemodialysis or repeat transplantation occurred in 3 patients (26, 354, and 750 d after RF ablation), all of whom had glomerular filtration rate (GFR) < 30 mL/min/1.73 m2 before ablation. For all patients, mean GFR 6 months after RF ablation (35.8 mL/min/1.73 m2 ± 17.7) was not significantly different (P = .8) from preprocedure GFR (36.2 mL/min/1.73 m2 ± 14.3). Proportional volume of allograft that was ablated did not correlate with immediate or long-term GFR changes. One patient died of unrelated comorbidities 52 months after ablation. No major complications occurred.Conclusions
RF ablation of renal allograft RCC provided effective oncologic control without adverse impact on graft viability. 相似文献13.
Alberto V. Mansilla Eugene E. Bivins Francisco Contreras Manuel A. Hernandez Nathan Kohler Julie W. Pepe 《Journal of vascular and interventional radiology : JVIR》2017,28(2):222-229
Purpose
To develop a scoring system that stratifies complexity of percutaneous ablation of renal tumors.Materials and Methods
Analysis was performed of 36 consecutive patients (mean age, 64 y; range, 30–89 y) who underwent CT-guided microwave (MW) ablation of 45 renal tumors (mean tumor diameter, 2.4 cm; range, 1.2–4.0 cm). Technical success and effectiveness were determined based on intraprocedural and follow-up imaging studies. The RENAL score and the proposed percutaneous renal ablation complexity (P-RAC) score were calculated for each tumor.Results
Technical success was 93.3% (n = 42). Biopsy of 38 of 45 renal tumors revealed 23 renal cell carcinomas. Median follow-up period was 9.7 months (range, 2.9–46.8 months). There were no tumor recurrences. One major complication, ureteropelvic junction stricture, occurred (2.6%). The P-RAC score was found to differ statistically from the RENAL score (t = 3.754, df = 44, P = .001). A positive correlation was found between the P-RAC score and number of antenna insertions (r = .378, n = 45, P = .011) and procedure duration (r = .328, n = 45, P = .028). No correlation was found between the RENAL score and number of MW antenna insertions (r = .110, n = 45, P = .472) or procedure duration (r = .263, n = 45, P = .081). Hydrodissection was significantly more common in the P-RAC high-complexity category than in low-complexity category (χ2 = 12.073, df = 2, P = .002).Conclusions
The P-RAC score may be useful in stratifying percutaneous renal ablation complexity. Further studies with larger sample sizes are necessary to validate the P-RAC score and to determine if it can predict risk of complications. 相似文献14.
Toshiyuki Irie Masashi Kuramochi Nobuyuki Takahashi Toshirou Kamoshida 《Cardiovascular and interventional radiology》2010,33(3):654-656
A huge mesenteric cyst in a 61-year-old female was treated by percutaneous ablation using ethanol. Marked shrinkage was achieved and regrowth was not seen 16 months after ablation. Resection is the standard therapy for mesenteric cysts, but it may be valuable to discuss the feasibility of percutaneous ablation before resection if the lesion wall is smooth and thin, and if solid nodules are not depicted on imaging. 相似文献
15.
Thanos L Mylona S Nikita A Ptohis N Kelekis DA 《Cardiovascular and interventional radiology》2007,30(2):289-292
An interesting case is presented of a 78-year-old patient with cirrhosis who was managed with combined treatment (surgery and radiofrequency (RF) ablation) for hepatocellular carcinoma (HCC) and has survived for 7(1/2) years. Elevation of the alpha-FP (alpha-fetoprotein) levels was noted 2 years after surgery. CT demonstrated two lesions: one central at the remaining right liver lobe, and the other at the excision site. Biopsy of the lesions confirmed the diagnosis of HCC for both of them. RF ablation of these two lesions was performed in one session with technical success. Four and a half years after the first RF ablation a new recurrence was demonstrated at the CT follow-up control. RF ablation was again applied successfully. The imaging findings and the therapeutic percutaneous management of this patient along with the natural course of HCC and its recurrence are discussed, and the literature concerning risk factors is reviewed. 相似文献
16.
Clinically suspected pulmonary embolism: is it safe to withhold anticoagulation after a negative spiral CT? 总被引:7,自引:0,他引:7
The goal of this study was 3-month clinical outcome in non-anticoagulated patients with clinically suspected acute pulmonary
embolism (PE) following a negative spiral CT. During a 6-month period 305 patients underwent spiral CT, of whom only 8 also
had a lung scintigraphy. In patients with a final CT report read as not positive for acute PE, all hospital records and answers
to a patient questionnaire were analyzed for episodes of venous thrombembolism (VTE). Acute PE was diagnosed at spiral CT
in 61 patients (20 %). Twenty-six of the remaining 244 patients were excluded from further analysis because of (a) long-term
anticoagulation due to symptomatic acute deep venous thrombosis (n = 5), clinically diagnosed acute PE (n = 2), chronic recurrent VTE (n = 4), and cardiac disorders (n = 5); and (b) a normal perfusion scintigram (n = 4) or a negative pulmonary arteriogram (n = 6). Three patients were lost to follow-up. Among the remaining 215 patients only 10 had undergone a negative lower extremity
venous study. Sixteen patients (7 %) died during the follow-up period, 6 of whom underwent autopsy. Venous thrombembolism
was diagnosed in three of the 215 patients (1.4 %, 95 % confidence limits: 0.5–4.0 %), one causing the patient's death. Two
patients had advanced thoracic malignancies and the third severe chronic obstructive pulmonary disease (84 years old). A negative
spiral CT may be able to exclude clinically significant acute PE with the same accuracy as a normal lung scintigraphy or a
negative pulmonary arteriography.
Received: 8 February 2000 Revised: 18 May 2000 Accepted: 22 May 2000 相似文献
17.
18.
19.
20.
Romaric Loffroy Sylvain Favelier Pierre Pottecher Pierre-Yves Genson Louis Estivalet Sophie Gehin Jean-Pierre Cercueil Denis Krausé 《World journal of radiology》2015,7(7):143-148
Visceral artery aneurysms (VAA) include splanchnic and renal artery aneurysms. They represent a rare clinical entity, although their detection is rising due to an increased use of cross-sectional imaging. Rupture is the most devastating complication, and is associated with a high morbidity and mortality. In addition, increased percutaneous endovascular interventions have raised the incidence of iatrogenic visceral artery pseudoaneurysms (VAPAs). For this reason, elective repair is preferable in the appropriately chosen patient. Controversy still exists regarding their treatment. Over the past decade, there has been steady increase in the utilization of minimally invasive, non-operative interventions, for vascular aneurysmal disease. All VAAs and VAPAs can technically be fixed by endovascular techniques but that does not mean they should. These catheter-based techniques constitute an excellent approach in the elective setting. However, in the emergent setting it may carry a higher morbidity and mortality. The decision for intervention has to take into account the size and the natural history of the lesion, the risk of rupture, which is high during pregnancy, and the relative risk of surgical or radiological intervention. For splanchnic artery aneurysms, we should recognize that we are not, in reality, well informed about their natural history. For most asymptomatic aneurysms, expectant treatment is acceptable. For large, symptomatic or aneurysms with a high risk of rupture, endovascular treatment has become the first-line therapy. Treatment of VAPAs is always mandatory because of the high risk of rupture. We present our point of view on interventional radiology in the splanchnic arteries, focusing on what has been achieved and the remaining challenges. 相似文献